Model SC500 Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION The SC series models are self-calibrating microprocessor- * Unamplified pressure or load based transducer signal conditioners when used with sig mod * Pressure or load with internal voltage amplifiers equipped transducers. Indicators are available with several dif- * Pressure or load with internal or external two-wire ferent types of input channels and output channels. When used current amplifiers with unamplified strain gage transducers that have the signature * ac/ac displacement transducer calibration module installed, these instruments will completely * dc/dc displacement transducer self calibrate zero, span, decimal point, and engineering units automatically. Available output channels for the SC500 include: * Contact relays for the two form C or three form A optional limits Input channels are available for a variety of transducers. Each * Isolated digital-to-analog voltage (5 Vdc or 0 Vdc to 10 Vdc) input channel includes an excitation power supply and either an isolated voltage (optional) or isolated current analog output In addition to the physical input and output channels, up to three (optional). virtual channels can be configured to assist in many potential applications. FEATURES * Choice of transducer inputs * Small 1/8 DIN form factor * Automatic setup, calibration via sig cal * Shunt-cal, mV/V or known load calibration * Peak/valley capture * Optional analog output and RS-232/RS-485 * Field selectable frequency response (up to 250 Hz) and calibration * Up to three virtual channels (optional) * CE approved Model SC500 Physical SPECIFICATIONS Communications output (optional) SPECIFICATIONS Characteristic Measure Form factor 1/8 DIN Characteristic Measure Case material Aluminum Serial setup and output Isolated RS-232 or RS-485 (factory option) Max. baud rate 38400 Baud Environmental SPECIFICATIONS Characteristic Measure Temperature, operating 5 C to 40 C [40 F to 105 F] Temperature, storage -30 C to 90 C [-40 F to 195 F] Display SPECIFICATIONS Characteristic Measure Display type Vacuum fluorescent Numeric display format +999999 to -999999 (0, 1, 2, 3, 4, 5 decimal places) Digit size, normal mode (H x W) 5 mm x 2,5 mm [0.2 in x 0.1 in] (with engineering units) Digit size, large mode (H x W) 10 mm x 5 mm [0.4 in x 0.2 in] (no engineering units) Engineering units display 4 characters, available in normal mode only Display update per second 4 Limits output (optional) SPECIFICATIONS Characteristic Measure Quantity 2 Form C or 3 Form A (factory option) Response time Same as input Relay energized when signal is less than, greater than, inside or outside set points Contact ratings 1 A @ 30 Vdc, 0.5 A @ 50 Vac Not RoHS compliant OPTION CODES Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Output options Power SPECIFICATIONS Characteristic Measure Power supply type ac (with included wall-mount adapter) or dc dc power supply requirements 10 Vdc to 26 Vdc @ 1 A ac wall-mount adapter (included) Interchangeable plugs for use in the Americas, Europe, the United Kingdom and Australia (100 Vac to 240 Vac) Analog output (optional) SPECIFICATIONS Characteristic Measure Voltage range 5 Vdc, 5 Vdc, 10 Vdc or 10 Vdc (field selectable) Isolation 500 V Digital-to-analog resolution 15 bits Frequency response Same as input 2 Honeywell * Sensing and Control 53a. RS-232 (not available with 53d) 53d. RS-485 (not available with 53a) 58a. Two limit set-points with form C contact relays (not available with 58h) 58h. Three limit set-points with form A contact relays (not available with 58a) 58i. Isolated digital-to-analog (DAC) voltage Programmable Single-Channel Transducer Indicator/Conditioner Mounting dimensions and characteristics For reference only TYPICAL SYSTEM DIAGRAM Input Strain gage millivolts High level volts/mA ac/ac displacement transducer Order code AE236 AE237 AE238 Transducer type Unamplified pressure or load Amplified pressure or load, dc/ dc displacement transducer Displacement transducer Range 0.5 mV/V to 21 mV/V 5 Vdc or 10 Vdc, 4 mA to 20 mA 0.1 VRMS to 15 VRMS Frequency response and resolution See table below See table below See table below Calibration type (field selectable) Shunt, mV/V, 2-, 3-, or 5-point known load Shunt, 2-, 3-, or 5-point known load 2-, 3-, or 5-point known load Transducer excitation 5 Vdc @ 60 mA max. 12 Vdc, 15 Vdc, 28 Vdc 3 Vac @ 5 kHz Push button Yes 100 % tare Yes Yes Push button Yes shunt test Yes No Flexible and expandable platform Resolution (counts) (not including min. 10 % overrange/underrange capability) Frequency response (Hz) field selectable Step response (ms) typical Strain gage High level ac/ac displacement transducer 2 (fast mode) 40 50000 50000 25000 2 440 50000 50000 25000 8 110 25000 25000 15000 16 55 20000 25000 10000 32 28 10000 20000 10000 50 16 5000 15000 5000 100 8 5000 10000 5000 250 3 2000 10000 2000 Honeywell * Sensing and Control 3 Model SC500 SC500 capabilities Front panel or remote tare Flexible user setup mV/V or shunt calibration or five-point calibration Remote setup User selectable display options Different alarm configurations (optional) 4 Honeywell * Sensing and Control Programmable Single-Channel Transducer Indicator/Conditioner SC500 capabilities User selectable filtering Math channel (optional) can act like PLC Sig cal auto setup Analog and digital outputs (optional) Honeywell * Sensing and Control 5 Model SC500 Programmable Single-Channel Transducer Indicator/Conditioner Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer's sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY * DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION * The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. * Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008825-1-EN IL50 GLO June 2008 Copyright (c) 2008 Honeywell International Inc. All rights reserved.