Product Selector
Tmax
Molded Case Circuit Breakers
T1…T8 General information ............................................................................................1
T1…T8 Selection information ..........................................................................................2
T1…T8 Catalogue number explanation ...........................................................................4
T1 100A .........................................................................................................................5
T2 100A .........................................................................................................................7
T3 225A .......................................................................................................................10
Ts3 225A ......................................................................................................................13
T4 250A .......................................................................................................................17
T5 400A / 600A ............................................................................................................ 23
T6 600A / 800A ............................................................................................................ 28
T7-T7M 1000A /1200A ................................................................................................31
T8V 1600A / 2000A / 2500A / 3000A ...........................................................................41
T1…T6 Accessories ..................................................................................................... 47
T1…T2 Dimensions ...................................................................................................... 61
T3 Dimensions ..............................................................................................................62
Ts3 Dimensions ............................................................................................................ 63
T4 Dimensions ..............................................................................................................64
T5 Dimensions ..............................................................................................................65
T6 Dimensions ..............................................................................................................66
T7 Dimensions ..............................................................................................................67
T8 Dimensions ..............................................................................................................68
T1...T7 Variable depth handle dimensions................................... ................................. .71
Molded Case Circuit Breakers
Index
Tmax Molded Case Circuit Breakers
T1…T8 General information ............................................................................................1
T1…T8 Selection information ..........................................................................................2
T1…T8 Catalogue number explanation ...........................................................................4
T1 100A .........................................................................................................................5
T2 100A .........................................................................................................................7
T3 225A .......................................................................................................................10
Ts3 225A ......................................................................................................................13
T4 250A .......................................................................................................................17
T5 400A / 600A ............................................................................................................ 23
T6 600A / 800A ............................................................................................................ 28
T7-T7M 1000A /1200A ................................................................................................31
T8V 1600A / 2000A / 2500A / 3000A ...........................................................................41
T1…T6 Accessories ..................................................................................................... 47
T1…T2 Dimensions ...................................................................................................... 61
T3 Dimensions ..............................................................................................................62
Ts3 Dimensions ............................................................................................................ 63
T4 Dimensions ..............................................................................................................64
T5 Dimensions ..............................................................................................................65
T6 Dimensions ..............................................................................................................66
T7 Dimensions ..............................................................................................................67
T8 Dimensions ..............................................................................................................68
T1...T7 Variable depth handle dimensions................................... ................................. .71
Molded Case Circuit Breakers
Index
Tmax Molded Case Circuit Breakers
ABB 1
AC1615S - 03/10
Introduction
ABB is once again demonstrating its
commitment to new product development
and its superiority in product technology.
Never before has the industry seen
such high performance, versatility and
standardization in a range of molded case
circuit breakers.
The ABB Tmax line of circuit breakers,
with a range up to 3000A, has several key
features that go along with its very small
size:
Double insulation – this construction
characteristic allows for the CSA/
UL listed eld installation of internal
accessories without exposure to
energized parts
Complete range of electrical and
mechanical accessories
Positive operation – breakers from ABB
ensure that the toggle indicates the
precise position of the moving contacts.
This guarantees safe and reliable
signaling by the device
Installation – Tmax molded case circuit
breakers can be installed in panels and
switchboards in either the horizontal
or vertical planes while being fed from
either end without any derating of their
performance characteristics
Interrupting ratings at 600VAC up to
100kAIC
• Compact size
All Tmax molded case circuit breakers
are CSA-UL listed and IEC rated for
global application and acceptance
All versions of the Tmax family are suitable
for reverse feed applications
The ABB Tmax series includes eight basic
frame sizes as well as the T1 single pole with
the range rated from 15A to 3000A at 600VAC.
Frame Sizes — Eight Basic Sizes
The ABB Tmax series includes eight basic
frame sizes as well as the T1 single pole with
the range rated from 15A to 3000A at 600VAC.
The various versions carry the following
interrupting capacities:
B Basic breaking capacity
N Normal breaking capacity
S Standard breaking capacity
H High breaking capacity
L Extra high breaking capacity
V Very high breaking capacity
Derived Versions
• Thermal magnetic
• Electronic
Molded case switches
Motor circuit protectors (MCPs)
Direct current (DC) rated
ABB Tmax Versions
Fixed: all models
Drawout or plug-in: T2, T3, Ts3, T4, T5, T6
and T7
UL File #E93565 (breakers and MCPs)
#E116596 (Accessories)
#E116595 (Molded case switches)
• CSA le #LR54280
Tmax
Molded Case Circuit Breakers
2 ABB
AC1615S - 03/10
Tmax
Selection Guide
Circuit Breakers for Power Distribution
T1 – Ts3
(1) In15A = 10kA@277VAC 10kA@347VAC
(2) In15A = 35kA@240VAC 14kA@480Y/277 VAC
(3) In from 15A up to 30A=65kA@480V AC
T1 1P T1 T2 T3 Ts3
Type Tmax T1 1p Tmax T1 Tmax T2 Tmax T3 Tmax Ts3 Tmax Ts3
Frame size [A] 100 100 100 225 150 225
Number of poles [Nr] 1 3-4 3-4 3-4 2-3-4 2-3-4
Rated voltage AC (50-60Hz) [V] 347 600Y/347 480 600Y/347 600 480
DC [V] 500 500 600 500
Interrupting
ratings BNSHNSNHLNHL
240V AC [kA rms] 50 (2) 65 100 50 65 65 100 150 65 100 150
277V AC [kA rms] 18 (1)
347V AC [kA rms] 14 (1)
480V AC [kA rms] 22 (2) 35 65 25 35 25 50 85 (3) 25 50 65
600Y/347V AC [kA rms] 10 10 10
600V AC [kA rms] 14 14 25
250V DC (2 poles in series) [kA rms] 25 25 35
500V DC (3 poles in series) [kA rms] 25 25 35
500V DC (2 poles in series) [kA rms] 35 50 65 20 35 50
600V DC (3 poles in series) [kA rms] 20 35 50
Trip units TMF ••
TMD/TMA
MA ••
Electronic
Dimensions H [in/mm] 5.12/130 5.12/130 5.12/130 5.9/150 6.7/170 6.7/170
W 3p [in/mm] 1/25.4 3/76 3.54/90 4.13/105 4.13/105 4.13/105
D [in/mm] 2.76/70 2.76/70 2.76/70 2.76/70 4.07/103.5 4.07/103.5
Mechanical life [No. operations] 25000 25000 25000 25000 25000 25000
ABB 3
AC1615S - 03/10
Tmax
Selection Guide
Circuit Breakers for Power Distribution
T4 – T8
Type Tmax T4 Tmax T5 Tmax T6 Tmax T7 Insulated Case
T8
Frame size [A] 250 400-600 (3) 800 1000-1200 1600, 2000,
2500 & 3000
3
600
Number of poles [Nr] 2-3-4 (4) 2-3-4 (4) 3-4 3-4
Rated voltage AC (50-60Hz) [V] 600 600 600 600
DC [V] 600 600 600 T8
Interrupting
ratings NSHLVNSHLVNSHL S H L T8V
240V AC [kA rms] 65 100 150 200 200 65 100 150 200 200 65 100 200 200 65 100 150 125
277V AC [kA rms]
347V AC [kA rms]
480V AC [kA rms] 25 35 65 100 150 25 35 65 100 150 35 50 65 100 50 65 100 125
600Y/347V AC [kA rms]
600V AC [kA rms] 18 25 35 65 100 18 25 35 65 100 20 25 35 42 25 50 65 100
250V DC (2 poles in series) [kA rms]
500V DC (3 poles in series) [kA rms]
500V DC (2 poles in series) [kA rms] 25 35 50 65 100 25 35 50 65 100 35 35 50 65
600V DC (3 poles in series) [kA rms] 16 25 35 50 65 16 25 35 50 65 20 20 35 50
Trip units TMF
TMD/TMA ••
MA
Electronic
Dimensions H [in/mm] 8.07/205 8.07/205 10.55/268 10.55/268 15 / 382
W 3p [in/mm] 4.13/105 5.51/140 8.26/210 8.26/210 16.8 / 427
D [in/mm] 4.07/103.5 4.07/103.5 4.07/103.5 6.06/154 (toggle)
7/178 (motor) 11.2 / 282
Mechanical life [No. operations] 20,000 20,000 20,000 10,000 15,000
(3) T5 600 with electronic trip units only and in three pole version-
(4) 2 pole T4N250 and T5N400 available only in N interrupting capacity.
T4 T5 T6 T7 T8
4 ABB
AC1615S - 03/10
Tmax
T3 S 080 T W - 4 xxx
Interrupting Rating Class
B = Basic
N = Normal
S = Standard
H = High
L = Extra High
V = Very high
Current Rating
015 = 15A
080 = 80A
100 = 100A
225 = 225A
250 = 250A
400 = 400A
600 = 600A
800 = 800A
1000 = 1000A
1200 = 1200A
Trip Unit Function
B = LS/I (AC only)
D = Molded Case Switch (MCS)
T = Thermal-magnetic
M = Magnetic only (MCP)
E5 = Electronic MCP (AC only)
C = LSI (AC only)
E = LSIG (AC only)
P = PR332/P LI
R = PR332/P LSI
S = PR332/P LSIG
Type Connectors
W = None
L = Lugs on top/bottom termi-
nals
T = Lugs on top terminal
B = Lugs on bottom terminal
Number Of Poles
-1 = 1 pole (T1 only)
-2 = 2 pole
-4 = 4 pole
None = 3 pole
Accessories (Added In Alpha-Numeric Order) (1)
A = Auxiliary Switch
S_ = Shunt trip with voltage code
U_ = Undervoltage release with voltage code
Frame Size
T1 = 100A
T2 = 100A
T3 = 225A
Ts3 = 225A
T4 = 250A
T5 = 400A, 600A
T6 = 600A, 800A
T7(2) = 1000A, 1200A
T8(3) = 1600A
= 2000A
= 2500A
= 3000A
16 = 1600A
20 = 2000A
25 = 2500A
30 = 3000A
(1) Consult ABB for factory installed accessories.
(2) For T7, refer to page 40
(3) For T8, refer to page 46
General Information
Catalog Number Explanation
ABB 5
AC1615S - 03/10
T1
T1
100A, 600Y/347VAC, 480VAC
Thermal-Magnetic
T1
General
The T1 breaker family ranges from 15 through 100 amperes. The T1 trip units
are non-interchangeable and use the very latest technology in electromagnetic
relays for overcurrent trip protection. Thermal overload protection is provided by
heat sensitive bimetals. Short-circuit protection for the breaker is accomplished
using a precise magnetic coil. State of the art construction in contacts and
arcing chambers aid in limiting damaging fault currents through the protected
circuits.
Standards
The UL489/CSA C22.2 No. 5 version of T1 also carries an IEC-60947-2 rating.
Versions
The T1 frame is available in two versions:
T = Thermal-magnetic, xed
D = Molded case switch
Performance Levels
The T1 breaker has two performance levels available:
B = Basic (Single Pole)
N = Normal (3 or 4 pole)
Number of Poles
The UL/CSA version of the T1 is available in single, three and four pole versions.
IEC versions of the T1 are also available with the same dimensions up to
160 amperes. Please contact ABB for details.
Reverse Feeding
All versions of the T1 family are suitable for reverse feed applications.
Molded Case Switches
UL/CSA switches include no overcurrent protection except for a high
instantaneous trip mechanism for self protection.
Dimensions 3P Fixed Version 5.12H x 3.00W x 2.76D
Weight 2.34 (Ibs)
IEC 60947-2 Interrupting Capacity (kA RMS)
Voltage Continuous Rating B (1-Pole) N
230VAC 16 – 160A 25 50
415VAC 16 – 160A 36
440VAC 16 - 160A 22
500VAC 16 - 160A 15
690VAC 16 – 160A 6
250VDC 2 pole series 16 - 160A 36
500VDC 2 pole series 16 – 160A 36
UL489 / CSA C22.2 Interrupting Capacity (kA RMS)
Voltage Continuous Rating B (1-Pole) N
240VAC 15
20 – 100
35
50
277VAC 15
20 – 100
10
18
347VAC 15
20 – 100
10
14
480Y/277VAC 15 14
480VAC 20 – 100 22
600Y/347VAC 15 – 100 10
250VDC 2 pole series 15 – 100A 25
500VDC 3 pole series 15 – 100A 25
6 Discount Schedule DS-ST ABB
AC1615S - 03/10
T1
T1
600Y/347VAC, 480VAC
Thermal-Magnetic/Molded Case Switch
T1-100A Frame, Thermal-Magnetic Trip Unit Fixed
T1-100A Frame, Thermal-Magnetic Trip Unit Fixed, 1 pole
T1-100A Frame, Molded Case Switch
1 Rated 480Y/277VAC for 15A.
2 When protected by a OCPD with appropriate ratings.
Breaker IC at Rating
Magnetic 3-Pole, 600Y/347VAC/500VDC List 4-Pole, 600Y/347VAC/500VDC List
480VAC Trip Part Number Price Part Number Price
14kA 15A 1000A T1N015TL T1N015TL-4
20A 1000A T1N020TL T1N020TL-4
25A 1000A T1N025TL T1N025TL-4
30A 1000A T1N030TL T1N030TL-4
40A 1000A T1N040TL T1N040TL-4
T1N 22kA 50A 1500A T1N050TL T1N050TL-4
60A 1500A T1N060TL T1N060TL-4
70A 1500A T1N070TL T1N070TL-4
80A 1500A T1N080TL T1N080TL-4
90A 1500A T1N090TL T1N090TL-4
100A 1500A T1N100TL T1N100TL-4
Breaker IC at Rating
Magnetic 1-Pole, 347VAC List
347VAC Trip Part Number Price
10kA 15A 1000A T1B015TL-1
20A 1000A T1B020TL-1
25A 1000A T1B025TL-1
30A 1000A T1B030TL-1
40A 1000A T1B040TL-1
T1B 14kA 50A 1500A T1B050TL-1
60A 1500A T1B060TL-1
70A 1500A T1B070TL-1
80A 1500A T1B080TL-1
90A 1500A T1B090TL-1
100A 1500A T1B100TL-1
Breaker Interrupting Rating
Magnetic 3-Pole, 600Y/347V/500VDC List 4-Pole, 600Y/347V/500VDC List
Capacity
(2) Trip Part Number Price Part Number Price
T1-D 240V, 50kA 100A 1000A T1N100DL TIN100DL-4
T-100A Frame,100% Rated Thermal-Magnetic Trip Unit Fixed
Breaker IC at Rating Magnetic 3-Pole, 600Y/347VAC/500VDC List
480VAC Trip Part Number Price
14kA 15 (1) 1000A T1NQ015TL
20 1000A T1NQ020TL
25 1000A T1NQ025TL
30 1000A T1NQ030TL
40 1000A T1NQ040TL
T1NQ 22kA 50 1500A T1NQ050TL
60 1500A T1NQ060TL
70 1500A T1NQ070TL
80 1500A T1NQ080TL
90 1500A T1NQ090TL
100 1500A T1NQ100TL
ABB 7
AC1615S - 03/10
T2
T2
100A, 480VAC
Thermal-Magnetic/Electronic/Current Limiting
T2
General
The T2 breaker family ranges from 10 through 100 amperes. The T2 trip units
are non-interchangeable and use the very latest technology in electromagnetic
relays for overcurrent trip protection as well as a version with microprocessor-
based electronic trip unit. Thermal overload protection is provided by heat
sensitive bimetals. State of the art construction in contacts and arcing chambers
aid in limiting damaging fault currents through the protected circuits.
Standards
The UL489/CSA C22.2 No. 5 version of T2 also carries an IEC-60947-2 rating.
Versions
The T2 frame is available in four versions:
T = Thermal-magnetic, xed
B = Adjustable LS/I electronic
M = Magnetic only (MCP)
E5 = Electronic instantaneous only (MCP)
Trip Functions
These tripping functions are available:
L = Long time
S = Short time
I = Instantaneous
Perfomance Levels
The T2 breaker has two performance levels available:
S = Standard
H = High - UL Current Limiting
Number of Poles
The UL/CSA version of the T2 is available in three and four pole versions.
IEC versions of the T2 are also available with the same dimensions up to
160 amperes. Please contact ABB for details.
Reverse Feeding
All versions of the T2 family are suitable for reverse feed applications.
UL489 / CSA C22.2 Interrupting Capacity (kA RMS)
Voltage Continuous Rating S H
240VAC 10 – 100A 65 150
480VAC 10 – 100A 35 65
Dimensions 3P Fixed Version 5.12H x 3.54W x 2.76D
Weight 2.84 (Ibs)
IEC 60947-2 Interrupting Capacity (kA RMS)
Voltage Continuous Rating S H
230VAC 1.6 – 160A 85 100
415VAC 1.6 – 160A 50 70
440V 1.6 – 160A 45 55
500V 1.6 – 160A 30 36
690VAC 1.6 – 160A 7 8
250VDC 2 pole series 1.6 – 160A 50 70
500VDC 3 pole series 1.6 – 160A 50 70
8 Discount Schedule DS-ST ABB
AC1615S - 03/10
T2
Breaker IC at Rating
Magnetic 3-Pole, 480VAC List 4-Pole, 480VAC List
480VAC Trip Part Number Price Part Number Price
T2
100A, 480VAC
Thermal-Magnetic/Current Limiting
15A 500A T2S015TW T2S015TW-4
20A 500A T2S020TW T2S020TW-4
25A 500A T2S025TW T2S025TW-4
30A 500A T2S030TW T2S030TW-4
40A 500A T2S040TW T2S040TW-4
T2S 35kA 50A 500A T2S050TW T2S050TW-4
60A 600A T2S060TW T2S060TW-4
70A 700A T2S070TW T2S070TW-4
80A 800A T2S080TW T2S080TW-4
90A 900A T2S090TW T2S090TW-4
100A 1000A T2S100TW T2S100TW-4
T2-100A Frame, Thermal-Magnetic Trip Unit Fixed
15A 500A T2H015TW T2H015TW-4
20A 500A T2H020TW T2H020TW-4
25A 500A T2H025TW T2H025TW-4
30A 500A T2H030TW T2H030TW-4
40A 500A T2H040TW T2H040TW-4
T2H 65kA 50A 500A T2H050TW T2H050TW-4
UL Current Limiting 60A 600A T2H060TW T2H060TW-4
70A 700A T2H070TW T2H070TW-4
80A 800A T2H080TW T2H080TW-4
90A 900A T2H090TW T2H090TW-4
100A 1000A T2H100TW T2H100TW-4
Breaker IC at Rating
Magnetic 3-Pole, 480VAC List 4-Pole, 480VAC List
480VAC Trip Part Number Price Part Number Price
15A 500A T2SQ015TW
20A 500A T2SQ020TW
25A 500A T2SQ025TW
30A 500A T2SQ030TW
40A 500A T2SQ040TW
T2SQ 35kA 50A 500A T2SQ050TW
60A 600A T2SQ060TW
70A 700A T2SQ070TW
80A 800A T2SQ080TW
90 A 900A T2SQ090TW
100A 1000A T2SQ100TW
Breaker IC at Rating
Magnetic 3-Pole, 480VAC List
480VAC Trip Part Number Price
T2-100A Frame, 100% Rated Thermal-Magnetic Trip Unit Fixed
15A 500A T2HQ015TW
20A 500A T2HQ020TW
25A 500A T2HQ025TW
30A 500A T2HQ030TW
T2HQ 40A 500A T2HQ040TW
UL Current Limiting 65kA 50A 500A T2HQ050TW
60A 600A T2HQ060TW
70A 700A T2HQ070TW
80A 800A T2HQ080TW
90A 900A T2HQ090TW
100A 1000A T2HQ100TW
Breaker IC at Rating
Magnetic 3-Pole, 480VAC List
480VAC Trip Part Number Price
ABB Discount Schedule DS-ST 9
AC1615S - 03/10
T2
25A T2S025BW T2S025BW-4
T2S 35kA PR221DS-LS/I 60A T2S060BW T2S060BW-4
100A T2S100BW T2S100BW-4
T2H 25A T2H025BW T2H025BW-4
UL Current Limiting 65kA PR221DS-LS/I 60A T2H060BW T2H060BW-4
100A T2H100BW T2H100BW-4
Breaker IC at Trip Unit CT 3-Pole, 480VAC List 4-Pole, 480VAC List
480VAC Type Rating Part Number Price Part Number Price
T2-100A Frame, Electronic Trip Unit (AC Only)
20A 120 - 240 T2S020MW
T2S 35kA Mag only 50A 300 - 600 T2S050MW
100A 600 – 1200 T2S100MW
20A 120 - 240 T2H020MW
T2H 65kA Mag only 50A 300 - 600 T2H050MW
100A 600 – 1200 T2H100MW
Breaker IC at Trip Unit Rating Adjustment 3-Pole, 480VAC List
480VAC Type Range Part Number Price
T2 -100A Frame, Motor Control Protection (MCP) Magnetic Only Trip Unit
Breaker IC at Trip Unit Rating Adjustment 3-Pole, 480VAC List
480VAC Type Range Part Number Price
35kA
Instantaneous 25A 25 - 250 T2S025E5W
T2S only 60A 60 - 600 T2S060E5W
100A 100 - 1000 T2S100E5W
65kA
Instantaneous 25A 25 - 250 T2H025E5W
T2H only 60A 60 - 600 T2H060E5W
100A 100 - 1000 T2H100E5W
T2 -100A Frame, Motor Control Protection (MCP) Magnetic Only Electronic Trip Unit (AC Only)
T2
100A, 480VAC
Electronic/Current Limiting, 100% Rated, MCP
25A T2SQ025BW
T2SQ 35kA PR221DS-LS/I 60A T2SQ060BW
100A T2SQ100BW
T2HQ 25A T2HQ025BW
UL Current Limiting 65kA PR221DS-LS/I 60A T2HQ060BW
100A T2HQ100BW
Breaker IC at Trip Unit CT 3-Pole, 480VAC List
480VAC Type Rating Part Number Price
T2-100A Frame, 100% Rated Electronic Trip Unit (AC Only)
10 ABB
AC1615S - 03/10
T3
T3
225A, 600Y/347VAC, 480VAC
Thermal-Magnetic
T3
General
The T3 breaker family ranges from 60 through 225 amperes. The T3 trip units
are non-interchangeable and use the very latest technology in electromagnetic
relays for overcurrent trip protection. Thermal overload protection is provided
by heat sensitive bimetals. Short-circuit protection begins at 10 times the
thermal rating of the breaker using a precise magnetic coil. State of the art
construction in contacts and arcing chambers aid in limiting damaging fault
currents through the protected circuits.
Standards
The UL489/CSA C22.2 No. 5 version of T3 also carries an IEC-60947-2 rating.
Versions
The T3 frame is available in three versions:
T = Thermal-magnetic, xed
M = Magnetic only (MCP)
D = Molded case switch
Performance Levels
The T3 breaker has two performance levels available:
N = Normal
S = Standard
Number of Poles
The UL/CSA version of the T3 is available in three and four pole versions.
IEC versions of the T3 are also available with the same dimensions up to 250
amperes. Please contact ABB for details.
Molded Case Switches
UL/CSA switches include no overcurrent protection except for a high
instantaneous trip mechanism for self protection.
Reverse Feeding
All versions of the T3 family are suitable for reverse feed application.
UL489 / CSA C22.2 Interrupting Capacity (kA RMS)
Voltage Continuous Rating N S
240VAC 60 – 225A 50 65
480VAC 60 – 225A 25 35
600Y/347VAC 60 – 225A 10 10
250VDC
(1) 60 – 225A 25 35
500VDC
(2) 60 – 225A 25 35
Dimensions 3P Fixed Version 5.9H x 4.13W x 2.76D
Weight 5.45 (Ibs)
IEC 60947-2 Interrupting Capacity (kA RMS)
Voltage Continuous Rating B (1-Pole) N
230VAC 63 – 250A 50 85
415VAC 63 – 250A 36 50
440V 63 – 250A 25 40
500V 63 – 250A 20 30
690VAC 63 – 250A 5 8
250VDC (1) 63 – 250A 36 50
500VDC (2) 63 – 250A 36 50
(1) 2 poles in series.
(2) 3 poles in series.
T3
ABB Discount Schedule DS-ST 11
AC1615S - 03/10
T3
225A, 600Y/347VAC, 480VAC
Thermal-Magnetic
60A 600A T3N060TW T3N060TW-4
70A 700A T3N070TW T3N070TW-4
80A 800A T3N080TW T3N080TW-4
90A 900A T3N090TW T3N090TW-4
100A 1000A T3N100TW T3N100TW-4
T3N 25kA 125A 1250A T3N125TW T3N125TW-4
150A 1500A T3N150TW T3N150TW-4
175A 1750A T3N175TW T3N175TW-4
200A 2000A T3N200TW T3N200TW-4
225A 2250A T3N225TW T3N225TW-4
Breaker IC at Rating
Magnetic 3-Pole, 600Y/347VAC-500DC List 4-Pole, 600Y/347VAC-500DC List
480VAC Trip Part Number Price Part Number Price
T3-225A Frame, Thermal-Magnetic Trip Unit Fixed
60A 600A T3S060TW T3S060TW-4
70A 700A T3S070TW T3S070TW-4
80A 800A T3S080TW
T3S080TW-4
90A 900A T3S090TW T3S090TW-4
100A 1000A T3S100TW T3S100TW-4
T3S 35kA 125A 1250A T3S125TW T3S125TW-4
150A 1500A T3S150TW T3S200TW-4
175A 1750A T3S175TW T3S175TW-4
200A 2000A T3S200TW
T3S200TW-4
225A 2250A T3S225TW T3S225TW-4
Breaker IC at Rating
Magnetic 3-Pole, 600Y/347VAC-500DC List 4-Pole, 600Y/347VAC-500DC List
480VAC Trip Part Number Price Part Number Price
60A 600A T3NQ060TW
70A 700A T3NQ070TW
80A 800A T3NQ080TW
90A 900A T3NQ090TW
100A 1000A T3NQ100TW
T3NQ 25kA 125A 1250A T3NQ125TW
150A 1500A T3NQ150TW
175A 1750A T3NQ175TW
200A 2000A T3NQ200TW
225A 2250A T3NQ225TW
Breaker IC at Rating
Magnetic 3-Pole, 600Y/347VAC-500VDC List
480VAC Trip Part Number Price
T3-225A Frame, 100% Rated Thermal-Magnetic Trip Unit Fixed
60A 600A T3SQ060TW
70A 700A T3SQ070TW
80A 800A T3SQ080TW
90A 900A T3SQ090TW
100A 1000A T3SQ100TW
T3SQ 35kA 125A 1250A T3SQ125TW
150A 1500A T3SQ150TW
175A 1750A T3SQ175TW
200A 2000A T3SQ200TW
225A 2250A T3SQ225TW
Breaker IC at Rating
Magnetic 3-Pole, 600Y/347VAC-500VDC List
480VAC Trip Part Number Price
12 Discount Schedule DS-ST ABB
AC1615S - 03/10
T3
T3
225A, 600Y/347VAC, 480VAC
MCP/Molded Case Switch
100A 600 1200 T3S100MW
T3S 35kA 10kA 35kA Mag only 125A 750 - 1500 T3S125MW
150A 900 - 1800 T3S150MW
200A 1200 - 2400 T3S200MW
Breaker IC at IC at IC at Trip Unit Rating Adjustment 3-Pole, 600Y/347VAC-500VDC List
480VAC 600Y/347VAC 500VDC Type Range Part Number Price
T3-225A Frame, Motor Control Protection (MCP) Magnetic Only Trip Unit
T3S-D 150A 1500A T3S150DW T3S150DW-4
225A 2250A T3S225DW T3S225DW-4
Breaker Rating Magnetic 3-Pole, 600Y/347VAC-500VDC List 4-Pole, 600Y/3 500VDC List
Trip Part Number Price Part Number Price
T3S-225A Frame, Molded Case Switch
ABB 13
AC1615S - 03/10
Ts3
150A 600VAC / 225A, 480VAC
Thermal-Magnetic
General
The Ts3 breaker family ranges from 15 through 225 amperes. The Ts3 trip
mech a nisms are non-interchangeable and use sen si tive elec tro mag net ic relays
for overcurrent trip pro tec tion. Heat sensitive bimetals are used for ther mal
over cur rent protection. Short-circuit cur rent protection begins at 10 times the
ther mal rating of the breaker and uses a magnetic coil principle.
Standards
The UL489/CSA C22.2 No. 5 version of Ts3 also carries an IEC-60947-2 rating.
Versions
To meet all application needs, the Ts3 is available in various versions:
T = Thermal-magnetic
D = Molded case switch
M = Magnetic only (MCP)
Performance Level
Each version is also available in different maximum fault in ter rupt ing levels
N = Normal
H = High
L = Extra high
Number of Poles
In UL/CSA form, the Ts3 is available in two pole or three pole versions, both
with the same dimensions. A four-pole version is also available in the N version.
For price estimation, add 35% to list price of selected version three pole
breaker, contact ABB for details.
Molded Case Switches
UL/CSA switches include no overcurrent protection except for a high
instantaneous trip mechanism for self protection. IEC type molded case
switches with no trip protection are also available.
Reverse Feeding
All versions of the Ts3 family are suitable for reverse feed application.
(1) 15-30A and 175-200-225A are 65kA at 480VAC
(2) Ts3 175A, 200A, 225A are rated 480VAC / 500DVC maximum
(3) Ts3 175A, 200A, 225A
(4) 2 poles in series
(5) 3 poles in series
Ts3
Ts3
Dimensions 3P Fixed Version 6.7H x 4.13W x 4.07D
Weight 6.75 (Ibs)
UL/CSA Interrupting Capacity (kA RMS)
UL489 / CSA C22.2
Voltage N H L
240 VAC 65 100 150
480 VAC 25 50 85 (1)
600 VAC (2) 14 14 25
500 VDC (4) 35 50 65
600 VDC (5) 20 35 50
Ts3/225A 500VDC (3) 20 35 50
IEC-60947-2 Interrupting Capacity (kA RMS)
Voltage N H L
230 VAC 65 100 170
380/400/415VAC 35 65 85
440 VAC 30 50 65
500 VAC 25 40 50
690 VAC 14 18 20
500 VDC 35 50 65
750 VDC 20 35 50
14 Discount Schedule DS-ST ABB
AC1615S - 03/10
Ts3
150A, 600VAC / 225A, 480VAC
Thermal-Magnetic
Ts3
Ts3-150A Frame, Thermal-Magnetic Trip Unit Fixed
Breaker IC at
600VAC Rating Magnetic
Trip
2-Pole, 480VAC/500VDC
Part Number
List
Price
3-Pole, 600VAC/600VDC
Part Number
List
Price
4-Pole, 600VAC/600VDC
Part Number
List
Price
Ts3N
14kA
15A 500A Ts3N015TW-2 Ts3N015TW Ts3N015TW-4
20A 500A Ts3N020TW-2 Ts3N020TW Ts3N020TW-4
25A 500A Ts3N025TW-2 Ts3N025TW Ts3N025TW-4
30A 500A Ts3N030TW-2 Ts3N030TW Ts3N030TW-4
35A 500A Ts3N035TW-2 Ts3N035TW Ts3N035TW-4
40A 500A Ts3N040TW-2 Ts3N040TW Ts3N040TW-4
50A 500A Ts3N050TW-2 Ts3N050TW Ts3N050TW-4
60A 600A Ts3N060TW-2 Ts3N060TW Ts3N060TW-4
70A 700A Ts3N070TW-2 Ts3N070TW Ts3N070TW-4
80A 800A Ts3N080TW-2 Ts3N080TW Ts3N080TW-4
90A 900A Ts3N090TW-2 Ts3N090TW Ts3N090TW-4
100A 1000A Ts3N100TW-2 Ts3N100TW Ts3N100TW-4
125A 1250A Ts3N125TW-2 Ts3N125TW Ts3N125TW-4
150A 1500A Ts3N150TW-2 Ts3N150TW Ts3N150TW-4
IC at
480VAC
25kA
175A (1) 1750A Ts3N175TW-2 Ts3N175TW Ts3N175TW-4
200A (1) 2000A Ts3N200TW-2 Ts3N200TW Ts3N200TW-4
225A (1) 2250A Ts3N225TW-2 Ts3N225TW Ts3N225TW-4
Breaker IC at
600VAC Rating Magnetic
Trip
2-Pole, 480VAC/500VDC
Part Number
List
Price
3-Pole, 600VAC/600VDC
Part Number
List
Price
Ts3H
14kA
15A 500A Ts3H015TW-2 Ts3H015TW
20A 500A Ts3H020TW-2 Ts3H020TW
25A 500A Ts3H025TW-2 Ts3H025TW
30A 500A Ts3H030TW-2 Ts3H030TW
35A 500A Ts3H035TW-2 Ts3H035TW
40A 500A Ts3H040TW-2 Ts3H040TW
50A 500A Ts3H050TW-2 Ts3H050TW
60A 600A Ts3H060TW-2 Ts3H060TW
70A 700A Ts3H070TW-2 Ts3H070TW
80A 800A Ts3H080TW-2 Ts3H080TW
90A 900A Ts3H090TW-2 Ts3H090TW
100A 1000A Ts3H100TW-2 Ts3H100TW
125A 1250A Ts3H125TW-2 Ts3H125TW
150A 1500A Ts3H150TW-2 Ts3H150TW
IC at
480VAC
50kA
175A (1) 1750A Ts3H175TW-2 Ts3H175TW
200A (1) 2000A Ts3H200TW-2 Ts3H200TW
225A (1) 2250A Ts3H225TW-2 Ts3H225TW
Breaker IC at
600VAC Rating Magnetic
Trip
2-Pole, 480VAC/500VDC
Part Number
List
Price
3-Pole, 600VAC/600VDC
Part Number
List
Price
Ts3L
25kA
15A 500A Ts3L015TW-2 Ts3L015TW
20A 500A Ts3L020TW-2 Ts3L020TW
25A 500A Ts3L025TW-2 Ts3L025TW
30A 500A Ts3L030TW-2 Ts3L030TW
35A 500A Ts3L035TW-2 Ts3L035TW
40A 500A Ts3L040TW-2 Ts3L040TW
50A 500A Ts3L050TW-2 Ts3L050TW
60A 600A Ts3L060TW-2 Ts3L060TW
70A 700A Ts3L070TW-2 Ts3L070TW
80A 800A Ts3L080TW-2 Ts3L080TW
90A 900A Ts3L090TW-2 Ts3L090TW
100A 1000A Ts3L100TW-2 Ts3L100TW
125A 1250A Ts3L125TW-2 Ts3L125TW
150A 1500A Ts3L150TW-2 Ts3L150TW
IC at
480VAC
65kA
175A (1) 1750A Ts3L175TW-2 Ts3L175TW
200A (1) 2000A Ts3L200TW-2 Ts3L200TW
225A (1) 2250A Ts3L225TW-2 Ts3L225TW
(1) 480VAC/500VDC maximum
Ts3
150A, 600VAC / 225A, 480VAC , 100% Rated
Thermal-Magnetic
Ts3
ABB Discount Schedule DS-ST 15
AC1615S - 03/10
Ts3-225A Frame, 100% Rated Thermal-Magnetic Trip Units
Breaker IC at
600VAC Rating Magnetic
Trip
3-Pole, 600VAC/600VDC
Part Number
List
Price
Ts3NQ
14kA
15A 500A Ts3NQ015TW
20A 500A Ts3NQ020TW
25A 500A Ts3NQ025TW
30A 500A Ts3NQ030TW
35A 500A Ts3NQ035TW
40A 500A Ts3NQ040TW
50A 500A Ts3NQ050TW
60A 600A Ts3NQ060TW
70A 700A Ts3NQ070TW
80A 800A Ts3NQ080TW
90A 900A Ts3NQ090TW
100A 1000A Ts3NQ100TW
125A 1250A Ts3NQ125TW
150A 1500A Ts3NQ150TW
IC at
480VAC
25kA
175A (1) 1750A Ts3NQ175TW
200A (1) 2000A Ts3NQ200TW
225A (1) 2250A Ts3NQ225TW
Breaker IC at
600VAC Rating Magnetic
Trip
3-Pole, 600VAC/600VDC
Part Number
List
Price
Ts3HQ
14kA
15A 500A Ts3HQ015TW
20A 500A Ts3HQ020TW
25A 500A Ts3HQ025TW
30A 500A Ts3HQ030TW
35A 500A Ts3HQ035TW
40A 500A Ts3HQ040TW
50A 500A Ts3HQ050TW
60A 600A Ts3HQ060TW
70A 700A Ts3HQ070TW
80A 800A Ts3HQ080TW
90A 900A Ts3HQ090TW
100A 1000A Ts3HQ100TW
125A 1250A Ts3HQ125TW
150A 1500A Ts3HQ150TW
IC at
480VAC
50kA
175A (1) 1750A Ts3HQ175TW
200A (1) 2000A Ts3HQ200TW
225A (1) 2250A Ts3HQ225TW
Breaker IC at
600VAC Rating Magnetic
Trip
3-Pole, 600VAC/600VDC
Part Number
List
Price
Ts3LQ
25kA
15A 500A Ts3LQ015TW
20A 500A Ts3LQ020TW
25A 500A Ts3LQ025TW
30A 500A Ts3LQ030TW
35A 500A Ts3LQ035TW
40A 500A Ts3LQ040TW
50A 500A Ts3LQ050TW
60A 600A Ts3LQ060TW
70A 700A Ts3LQ070TW
80A 800A Ts3LQ080TW
90A 900A Ts3LQ090TW
100A 1000A Ts3LQ100TW
125A 1250A Ts3LQ125TW
150A 1500A Ts3LQ150TW
IC at
480VAC
65kA
175A (1) 1750A Ts3LQ175TW
200A (1) 2000A Ts3LQ200TW
225A (1) 2250A Ts3LQ225TW
(1) 480VAC/500VDC maximum
16 Discount Schedule DS-ST ABB
AC1615S - 03/10
(1) 480VAC/500VDC Maximum
Ts3
Ts3
150A, 600VAC / 225A, 450VAC, 480VAC
MCP/Molded Case Switch
Ts3-225A Frame, Molded Case Switch
Type Voltage (max.) Magnetic Trip Amps 3-P
ole 600VAC/600VDC
Part Number
List
Price
4-
Pole, 600VAC/600VDC
Part Number
List
Price
Ts3H 600VAC/600VDC 1500 150 Ts3H150DW Ts3H150DW-4
480VAC/500VDC 2250 225 (1) Ts3H225DW Ts3H225DW-4
Ts3-225A Frame, Motor Control Protection (MCP) Magnetic Only Trip Unit
Breaker IC at IC at IC at IC at Trip Unit Type Rating Adjustment
Range
3-Pole, 600VAC/600VDC
Part Number
List
Price
Ts3L
25kA 10kA -50kA Mag only 3 12-36 Ts3L003MW
25kA 10kA -50kA Mag only 5 20-60 Ts3L005MW
25kA 10kA -50kA Mag only 10 40-120 Ts3L010MW
25kA 10kA 65kA 50kA Mag only 25 100-300 Ts3L025MW
85kA 25kA 65kA 50kA Mag only 50 200-600 Ts3L050MW
85kA 25kA 65kA 50kA Mag only 100 400-1200 Ts3L100MW
85kA 25kA 65kA 50kA Mag only 125 500-1500 Ts3L125MW
85kA 25kA 50kA 50kA Mag only 150 600-1500 Ts3L150MW
65kA -50kA -Mag only 175 (1) 700-2100 Ts3L175MW
65kA -50kA -Mag only 200 (1) 800-2400 Ts3L200MW
480VAC 600VAC 500VDC 600VDC
ABB 17
AC1615S - 03/10
T4
UL489 / CSA C22.2 Interrupting Capacity (kA RMS)
T4
250A, 600VAC
Electronic and Thermal-Magnetic
T4
General
The T4 breaker is a 250 amp frame with either a microprocessor based over
current protective trip system or a thermal magnetic trip unit.
Standards
The UL489/CSA C22.2 No. 5 version of T4 also carries an IEC-60947-2 rating.
Versions
To meet all application requirements, the T4 is available in the following
versions:
T = Thermal-magnetic
B = Selectable & adjustable LI or LS
C = Adjustable LSI
E = Adjustable LSIG
D = Molded Case Switch
E5 = Electronic instantaneous only (MCP)
Trip Functions
These trip functions are available:
L = Long time
S = Short time
I = Instantaneous
G = Ground fault
Performance Levels
Each version is also available in different maximum fault interrupting levels:
N = Normal
S = Standard
H = High - UL Current Limiting
L = Extra high
V = Very high - UL Current Limiting
Number of Poles (3)
The T4 is available as a 2, 3 and 4 pole breaker. The 2 and 3 pole versions have
the same dimensions.
Reverse Feeding
All versions of the T4 family are suitable for reverse feed application.
Voltage Continuous Rating N S H L V
240VAC 20 - 250A 65 100 150 200 200
480VAC 20 - 250A 25 35 65 100 150
600VAC 20 - 250A 18 25 35 65 100
500VDC (1) 20 - 250A 25 35 50 65 100
600VDC (2) 20 - 250A 16 25 35 50 65
(1) 2 poles in series.
(2) 3 poles in series.
(3) 2 pole breakers available in N version only. 4 pole breakers available in N and H version only.
Dimensions 3P Fixed Version 8.07H x 4.13W x 4.07D
Weight 6.18 (Ibs)
Voltage Continuous Rating N S H L V
230VAC 20 - 320A 70 85 100 200 200
415VAC 20 - 320A 36 50 70 120 200
440VAC 20 - 320A 30 40 65 100 180
500VAC 20 - 320A 25 30 50 85 150
690VAC 20 - 320A 20 25 40 70 80
750VDC 20 - 320A 18 25 36 50 70
IEC 60947-2 Interrupting Capacity (kA RMS)
18 Discount Schedule DS-ST ABB
AC1615S - 03/10
T4
T4
250A, 600VAC
Electronic (AC Only)
T4-100A Frame, Electronic Trip Unit (AC Only) 40-100A Adjustable Range
Breaker IC at
600VAC
Trip
Unit
2-Pole, 600VAC
Part Number
List
Price
3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
PR221 LS/I T4N100BW-2 T4N100BW T4N100BW-4
T4N 18kA PR222 LSI T4N100CW-2 T4N100CW T4N100CW-4
PR222 LSIG T4N100EW-2 T4N100EW T4N100EW-4
PR221 LS/I T4S100BW
T4S 25kA PR222 LSI T4S100CW
PR222 LSIG T4S100EW
T4H
UL Current Limiting
PR221 LS/I T4H100BW T4H100BW-4
35kA PR222 LSI T4H100CW T4H100CW-4
PR222 LSIG T4H100EW T4H100EW-4
PR221 LS/I T4L100BW
T4L 65kA PR222 LSI T4L100CW
PR222 LSIG T4L100EW
T4V
UL Current Limiting
PR221 LS/I T4V100BW
100kA PR222 LSI T4V100CW
PR222 LSIG T4V100EW
T4-150A Frame, Electronic Trip Unit (AC Only) 60-150A Adjustable Range
Breaker IC at
600VAC
Trip
Unit
2-Pole, 600VAC
Part Number
List
Price
3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
PR221 LS/I T4N150BW-2 T4N150BW T4N150BW-4
T4N 18kA PR222 LSI T4N150CW-2 T4N150CW T4N150CW-4
PR222 LSIG T4N150EW-2 T4N150EW T4N150EW-4
PR221 LS/I T4S150BW
T4S 25kA PR222 LSI T4S150CW
PR222 LSIG T4S150EW
T4H
UL Current Limiting
PR221 LS/I T4H150BW T4H150BW-4
35kA PR222 LSI T4H150CW T4H150CW-4
PR222 LSIG T4H150EW T4H150EW-4
PR221 LS/I T4L150BW
T4L 65kA PR222 LSI T4L150CW
PR222 LSIG T4L150EW
T4V
UL Current Limiting 100kA
PR221 LS/I
PR222 LSI
PR222 LSIG
T4V150BW
T4V150CW
T4V150EW
T4V
UL current limiting
PR221 LS/I T4V150BW
100 PR222 LSI T4V150CW
PR222 LSIG T4V150EW
T4-250A Frame, Electronic Trip Unit (AC Only) 100-250A Adjustable Range
Breaker IC at
600VAC
Trip
Unit
2-Pole, 600VAC
Part Number
List
Price
3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
PR221 LS/I T4N250BW-2 T4N250BW T4N250BW-4
T4N 18kA PR222 LSI T4N250CW-2 T4N250CW T4N250CW-4
PR222 LSIG T4N250EW-2 T4N250EW T4N250EW-4
PR221 LS/I T4S250BW
T4S 25kA PR222 LSI T4S250CW
PR222 LSIG T4S250EW
T4H
UL Current Limiting
PR221 LS/I T4H250BW T4H250BW-4
35kA PR222 LSI T4H250CW T4H250CW-4
PR222 LSIG T4H250EW T4H250EW-4
PR221 LS/I T4L250BW
T4L 65kA PR222 LSI T4L250CW
PR222 LSIG T4L250EW
T4V
UL Current Limiting
PR221 LS/I T4V250BW
100kA PR222 LSI T4V250CW
PR222 LSIG T4V250EW
T4
ABB Discount Schedule DS-ST 19
AC1615S - 03/10
T4
250A, 600VAC
Electronic 100% Rated (AC Only)
Breaker IC at
600VAC
Trip
Unit
3-Pole, 600VAC
Part Number
List
Price
T4NQ 18kA
PR221 LS/I T4NQ100BW
PR222 LSI T4NQ100CW
PR222 LSIG T4NQ100EW
T4SQ 25kA
PR221 LS/I T4SQ100BW
PR222 LSI T4SQ100CW
PR222 LSIG T4SQ100EW
T4HQ
UL Current Limiting 35kA
PR221 LS/I T4HQ100BW
PR222 LSI T4HQ100CW
PR222 LSIG T4HQ100EW
T4LQ 65kA
PR221 LS/I T4LQ100BW
PR222 LSI T4LQ100CW
PR222 LSIG T4LQ100EW
T4VQ
UL Current Limiting 100kA
PR221 LS/I T4VQ100BW
PR222 LSI T4VQ100CW
PR222 LSIG T4VQ100EW
Breaker IC at
600VAC
Trip
Unit
3-Pole, 600V
Part Number
List
Price
T4NQ 18kA
PR221 LS/I T4NQ150BW
PR222 LSI T4NQ150CW
PR222 LSIG T4NQ150EW
T4SQ 25kA
PR221 LS/I T4SQ150BW
PR222 LSI T4SQ150CW
PR222 LSIG T4SQ150EW
T4HQ
UL Current Limiting 35kA
PR221 LS/I T4HQ150BW
PR222 LSI T4HQ150CW
PR222 LSIG T4HQ150EW
T4LQ 65kA
PR221 LS/I T4LQ150BW
PR222 LSI T4LQ150CW
PR222 LSIG T4LQ150EW
T4VQ
UL Current Limiting 100kA
PR221 LS/I T4VQ150BW
PR222 LSI T4VQ150CW
PR222 LSIG T4VQ150EW
Breaker IC at
600VAC
Trip
Unit
3-Pole, 600V
Part Number
List
Price
T4NQ 18kA
PR221 LS/I T4NQ250BW
PR222 LSI T4NQ250CW
PR222 LSIG T4NQ250EW
T4SQ 25kA
PR221 LS/I T4SQ250BW
PR222 LSI T4SQ250CW
PR222 LSIG T4SQ250EW
T4HQ
UL Current Limiting 35kA
PR221 LS/I T4HQ250BW
PR222 LSI T4HQ250CW
PR222 LSIG T4HQ250EW
T4LQ 65kA
PR221 LS/I T4LQ250BW
PR222 LSI T4LQ250CW
PR222 LSIG T4LQ250EW
T4VQ
UL Current Limiting 100kA
PR221 LS/I T4VQ250BW
PR222 LSI T4VQ250CW
PR222 LSIG T4VQ250EW
T4-250A Frame, 100% Rated Electronic Trip Unit (AC Only) 100-250A Adjustable Range
T4-150A Frame, 100% Rated Electronic Trip Unit (AC Only) 60-150A Adjustable Range
20 Discount Schedule DS-ST ABB
AC1615S - 03/10
T4
T4
250A, 600VAC
Thermal-Magnetic Trip Units
Breaker IC at
600VAC Rating Magnetic
Trip
3-Pole, 600VAC/600VDC
Part Number
List
Price
4-Pole, 600VAC/600VDC
Part Number
List
Price
T4N 18kA
20A 500 T4N020TW T4N020TW-4
30A (21-30A) 500 T4N030TW T4N030TW-4
40A (28-40A) 500 T4N040TW T4N040TW-4
50A (35-50A) 500 T4N050TW T4N050TW-4
80A (56-80A)
400-800 T4N080TW T4N080TW-4
100A (70-100A)
500-1000 T4N100TW T4N100TW-4
125A (88-125A)
625-1250 T4N125TW T4N125TW-4
150A (105-150A)
750-1500 T4N150TW T4N150TW-4
200A (140-200A)
1000-2000 T4N200TW T4N200TW-4
250A (175-250A)
1250-2500 T4N250TW T4N250TW-4
T4S 25kA
20A 500 T4S020TW
30A (21-30A) 500 T4S030TW
40A (28-40A) 500 T4S040TW
50A (35-50A) 500 T4S050TW
80A (56-80A)
400-800 T4S080TW
100A (70-100A)
500-1000 T4S100TW
125A (88-125A)
625-1250 T4S125TW
150A (105-150A)
750-1500 T4S150TW
200A (140-200A)
1000-2000 T4S200TW
250A (175-250A)
1250-2500 T4S250TW
T4H
UL Current Limiting 35kA
20A 500 T4H020TW T4H020TW-4
30A (21-30A) 500 T4H030TW T4H030TW-4
40A (28-40A) 500 T4H040TW T4H040TW-4
50A (35-50A) 500 T4H050TW T4H050TW-4
80A (56-80A)
400-800 T4H080TW T4H080TW-4
100A (70-100A)
500-1000 T4H100TW T4H100TW-4
125A (88-125A)
625-1250 T4H125TW T4H125TW-4
150A (105-150A)
750-1500 T4H150TW T4H150TW-4
200A (140-200A)
1000-2000 T4H200TW T4H200TW-4
250A (175-250A)
1250-2500 T4H250TW T4H250TW-4
T4L 65kA
20A 500 T4L020TW
30A (21-30A) 500 T4L030TW
40A (28-40A) 500 T4L040TW
50A (35-50A) 500 T4L050TW
80A (56-80A)
400-800 T4L080TW
100A (70-100A)
500-1000 T4L100TW
125A (88-125A)
625-1250 T4L125TW
150A (105-150A)
750-1500 T4L150TW
200A (140-200A)
1000-2000 T4L200TW
250A (175-250A)
1250-2500 T4L250TW
T4V
UL Current Limiting 100kA
20A 500 T4V020TW
30A (21-30A) 500 T4V030TW
40A (28-40A) 500 T4V040TW
50A (35-50A) 500 T4V050TW
80A (56-80A)
400-800 T4V080TW
100A (70-100A)
500-1000 T4V100TW
125A (88-125A)
625-1250 T4V125TW
150A (105-150A)
750-1500 T4V150TW
200A (140-200A)
1000-2000 T4V200TW
250A (175-250A)
1250-2500 T4V250TW
Breaker IC at
600VAC Rating Magnetic
Trip
2-Pole, 600VAC/500VDC
Part Number
List
Price
T4N 18kA
30A (21-30A) 500 T4N030TW-2
40A (28-40A) 500 T4N040TW-2
50A (35-50A) 500 T4N050TW-2
80A (56-80A)
400-800 T4N080TW-2
100A (70-100A)
500-1000 T4N100TW-2
125A (88-125A)
625-1250 T4N125TW-2
150A (100-150A)
750-1500 T4N150TW-2
200A (140-200A)
1000-2000 T4N200TW-2
250A (175-250A)
1250-2500 T4N250TW-2
T4-250A Frame, Thermal-Magnetic Trip Unit
T4
ABB Discount Schedule DS-ST 21
AC1615S - 03/10
T4
250A, 600VAC
100% Rated Thermal-Magnetic Trip Units
T4-250A Frame, 100% Rated Thermal-Magnetic Trip Unit
Breaker IC at
600VAC Rating Magnetic
Trip
3-Pole, 600VAC/600VDC
Part Number
List
Price
T4NQ 18kA
20A 500 T4NQ020TW
30A (21-30A) 500 T4NQ030TW
40A (28-40A) 500 T4NQ040TW
50A (35-50A) 500 T4NQ050TW
80A (56-80A)
400-800 T4NQ080TW
100A (70-100A)
500-1000 T4NQ100TW
125A (88-125A)
625-1250 T4NQ125TW
150A (105-150A)
750-1500 T4NQ150TW
200A (140-200A)
1000-2000 T4NQ200TW
250A (175-250A)
1250-2500 T4NQ250TW
T4SQ 25kA
20A 500 T4SQ020TW
30A (21-30A) 500 T4SQ030TW
40A (28-40A) 500 T4SQ040TW
50A (35-50A) 500 T4SQ050TW
80A (56-80A)
400-800 T4SQ080TW
100A (70-100A)
500-1000 T4SQ100TW
125A (88-125A)
625-1250 T4SQ125TW
150A (105-150A)
750-1500 T4SQ150TW
200A (140-200A)
1000-2000 T4SQ200TW
250A (175-250A)
1250-2500 T4SQ250TW
T4HQ 35kA
20A 500 T4HQ020TW
30A (21-30A) 500 T4HQ030TW
40A (28-40A) 500 T4HQ040TW
50A (35-50A) 500 T4HQ050TW
80A (56-80A)
400-800 T4HQ080TW
100A (70-100A)
500-1000 T4HQ100TW
125A (88-125A)
625-1250 T4HQ125TW
150A (105-150A)
750-1500 T4HQ150TW
200A (140-200A)
1000-2000 T4HQ200TW
250A (175-250A)
1250-2500 T4HQ250TW
T4LQ 65kA
20A 500 T4LQ020TW
30A (21-30A) 500 T4LQ030TW
40A (28-40A) 500 T4LQ040TW
50A (35-50A) 500 T4LQ050TW
80A (56-80A)
400-800 T4LQ080TW
100A (70-100A)
500-1000 T4LQ100TW
125A (88-125A)
625-1250 T4LQ125TW
150A (105-150A)
750-1500 T4LQ150TW
200A (140-200A)
1000-2000 T4LQ200TW
250A (175-250A)
1250-2500 T4LQ250TW
T4VQ 100kA
20A 500 T4VQ020TW
30A (21-30A) 500 T4VQ030TW
40A (28-40A) 500 T4VQ040TW
50A (35-50A) 500 T4VQ050TW
80A (56-80A)
400-800 T4VQ080TW
100A (70-100A)
500-1000 T4VQ100TW
125A (88-125A)
625-1250 T4VQ125TW
150A (105-150A)
750-1500 T4VQ150TW
200A (140-200A)
1000-2000 T4VQ200TW
250A (175-250A)
1250-2500 T4VQ250TW
22 Discount Schedule DS-ST ABB
AC1615S - 03/10
T4
250A, 600VAC
MCP (Instantaneous Only), Molded Case Switch
T4-250A Frame, Motor Control Protection (MCP) Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip Unit Type Rating Adjustment
Range
3-Pole, 600VAC
Part Number
List
Price
T4N 18kA PR221 DS-I
100A 100-1000 T4N100E5W
150A 150-1500 T4N150E5W
250A 250-2500 T4N250E5W
T4S 25kA PR221 DS-I
100A 100-1000 T4S100E5W
150A 150-1500 T4S150E5W
250A 250-2500 T4S250E5W
T4H 35kA PR221 DS-I
100A 100-1000 T4H100E5W
150A 150-1500 T4H150E5W
250A 250-2500 T4H250E5W
T4L 65kA PR221 DS-I
100A 100-1000 T4L100E5W
150A 150-1500 T4L150E5W
250A 250-2500 T4L250E5W
T4-250A Frame, Molded Case Switch
Type Amps Magnetic
Trip
3-Pole, 600VAC/600VDC
Part Number
List
Price
4-Pole, 600VAC/600VDC
Part Number
List
Price
T4N-D 250 3000 T4N250DW
T4S-D 250 3000 T4S250DW
T4H-D 250 3000 T4H250DW T4H250DW-4
T4L-D 250 3000 T4L250DW
T4V-D 250 3000 T4V250DW
T4
ABB 23
AC1615S - 03/10
T5
400A / 600A, 600VAC
Electronic and Thermal-Magnetic
T5
General
The T5 breaker is a 400/600 amp frame with either a microprocessor based
over current protective trip system or a thermal magnetic trip unit. (3)
Standards
The UL489/CSA C22.2 No. 5 version of T5 also carries an IEC-60947-2 rating.
Versions
To meet all application requirements, the T5 is available in the following
versions:
T = Thermal-magnetic
B = Selectable & adjustable LI or LS
C = Adjustable LSI
E = Adjustable LSIG
D = Molded Case Switch
E5 = Electronic instantaneous only (MCP)
Trip Functions
These trip functions are available:
L = Long time
S = Short time
I = Instantaneous
G = Ground fault
Performance Levels
Each version is also available in different maximum fault interrupting levels:
N = Normal
S = Standard
H = High
L = Extra high
V = Very high
Number of Poles (4)
The T5 is available as a 2, 3 and 4 pole breaker. The 2 and 3 pole versions have
the same dimensions.
Reverse Feeding
All versions of the T5 family are suitable for reverse feed application.
UL489 / CSA C22.2 Interrupting Capacity (kA RMS)
Voltage N S H L V
240VAC 65 100 150 200 200
480VAC 25 35 65 100 150
600VAC 18 25 35 65 100
500VDC
(1) 25 35 50 65 100
600VDC
(2) 16 25 35 50 65
(1) 2 poles in series.
(2) 3 poles in series.
(3) T5 600A not available with thermal magnetic trip unit.
(4) 2 pole available in N version only. 4 pole available in N and H version only.
Dimensions 3P Fixed Version 8.07H x 5.51W x 4.07D
Weight 8.55 (Ibs)
IEC 60947-2 Interrupting Capacity (kA RMS)
Voltage N S H L V
230VAC 70 85 100 200 200
415VAC 36 50 70 120 200
440VAC 30 40 65 100 180
500VAC 25 30 50 85 150
690VAC 20 25 40 70 80
750VDC (2) 16 25 36 50 70
T5
24 Discount Schedule DS-ST ABB
AC1615S - 03/10
T5
T5
400A / 600A
Electronic (AC Only)
T5-300A Frame, Electronic Trip Unit (AC Only) 120-300A Adjustable Range
Breaker IC at
600VAC
Trip
Unit
2-Pole, 600VAC
Part Number
List
Price
3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T5N 18kA
PR221 LS/I T5N300BW-2 T5N300BW T5N300BW-4
PR222 LSI T5N300CW-2 T5N300CW T5N300CW-4
PR222 LSIG T5N300EW-2 T5N300EW T5N300EW-4
T5S 25kA
PR221 LS/I T5S300BW
PR222 LSI T5S300CW
PR222 LSIG T5S300EW
T5H 35kA
PR221 LS/I T5H300BW T5H300BW-4
PR222 LSI T5H300CW T5H300CW-4
PR222 LSIG T5H300EW T5H300EW-4
T5L 65kA
PR221 LS/I T5L300BW
PR222 LSI T5L300CW
PR222 LSIG T5L300EW
T5V 100kA
PR221 LS/I T5V300BW
PR222 LSI T5V300CW
PR222 LSIG T5V300EW
T5-400A Frame, Electronic Trip Unit (AC Only) 160-400A Adjustable Range
Breaker IC at
600VAC
Trip
Unit
2-Pole, 600VAC
Part Number
List
Price
3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
18kA
PR221 LS/I T5N400BW-2 T5N400BW T5N400BW-4
T5N PR222 LSI T5N400CW-2 T5N400CW T5N400CW-4
PR222 LSIG T5N400EW-2 T5N400EW T5N400EW-4
25kA
PR221 LS/I T5S400BW
T5S PR222 LSI T5S400CW
PR222 LSIG T5S400EW
T5H 35kA
PR221 LS/I T5H400BW T5H400BW-4
PR222 LSI T5H400CW T5H400CW-4
PR222 LSIG T5H400EW T5H400EW-4
65kA
PR221 LS/I T5L400BW
T5L PR222 LSI T5L400CW
PR222 LSIG T5L400EW
T5V 100kA
PR221 LS/I T5V400BW
PR222 LSI T5V400CW
PR222 LSIG T5V400EW
Breaker IC at
600VAC
Trip
Unit
3-Pole, 600VAC
Part Number
List
Price
18kA
PR221 LS/I T5N600BW
T5N PR222 LSI T5N600CW
PR222 LSIG T5N600EW
25kA
PR221 LS/I T5S600BW
T5S PR222 LSI T5S600CW
PR222 LSIG T5S600EW
35kA
PR221 LS/I T5H600BW
T5H PR222 LSI T5H600CW
PR222 LSIG T5H600EW
65kA
PR221 LS/I T5L600BW
T5L PR222 LSI T5L600CW
PR222 LSIG T5L600EW
100kA
PR221 LS/I T5V600BW
T5V PR222 LSI T5V600CW
PR222 LSIG T5V600EW
T5-600A Frame, Electronic Trip Unit (AC Only) 240-600A Adjustable Range
ABB Discount Schedule DS-ST 25
AC1615S - 03/10
T5
T5
400A
100% Rated Electronic (AC only) (1)
Breaker IC at
600VAC
Trip
Unit
3-Pole, 600VAC
Part Number
List
Price
T5N 18kA
PR221 LS/I T5NQ400BW
PR222 LSI T5NQ400CW
PR222 LSIG T5NQ400EW
T5S 25kA
PR221 LS/I T5SQ400BW
PR222 LSI T5SQ400CW
PR222 LSIG T5SQ400EW
T5H 35kA
PR221 LS/I T5HQ400BW
PR222 LSI T5HQ400CW
PR222 LSIG T5HQ400EW
T5L 65kA
PR221 LS/I T5LQ400BW
PR222 LSI T5LQ400CW
PR222 LSIG T5LQ400EW
T5V 100kA
PR221 LS/I T5VQ400BW
PR222 LSI T5VQ400CW
PR222 LSIG T5VQ400EW
Breaker IC at
600VAC
Trip
Unit
3-Pole, 600VAC
Part Number
List
Price
T5N 18kA
PR221 LS/I T5NQ300BW
PR222 LSI T5NQ300CW
PR222 LSIG T5NQ300EW
T5S 25kA
PR221 LS/I T5SQ300BW
PR222 LSI T5SQ300CW
PR222 LSIG T5SQ300EW
T5H 35kA
PR221 LS/I T5HQ300BW
PR222 LSI T5HQ300CW
PR222 LSIG T5HQ300EW
T5L 65kA
PR221 LS/I T5LQ300BW
PR222 LSI T5LQ300CW
PR222 LSIG T5LQ300EW
T5V 100kA
PR221 LS/I T5VQ300BW
PR222 LSI T5VQ300CW
PR222 LSIG T5VQ300EW
(1) T5 600A not available as 100% rated
T5-300A Frame, 100% Rated Electronic Trip Units (AC Only) 120-300A Adjustable Range
T5-400A Frame, 100% Rated Electronic Trip Units (AC Only) 160-400A Adjustable Range
26 Discount Schedule DS-ST ABB
AC1615S - 03/10
T5
T5
400A, 600VAC
Thermal-Magnetic (1)
T5-300/400A Frame, Thermal-Magnetic Trip Unit
Breaker IC at
600VAC Rating Magnetic
Trip
2-Pole, 600VAC/500VDC
Part Number
List
Price
3-Pole, 600VAC/600VDC
Part Number
List
Price
4-Pole, 600VAC/600VDC
Part Number
List
Price
T5N 18kA 300A 1500-3000 T5N300TW-2 T5N300TW T5N300TW-4
400A 2000-4000 T5N400TW-2 T5N400TW T5N400TW-4
T5S 25kA 300A 1500-3000 T5S300TW T5S300TW-4
400A 2000-4000 T5S400TW T5S400TW-4
T5H 35kA 300A 1500-3000 T5H300TW T5H300TW-4
400A 2000-4000 T5H400TW T5H400TW-4
T5L 65kA 300A 1500-3000 T5L300TW T5L300TW-4
400A 2000-4000 T5L400TW T5L400TW-4
T5V 100kA 300A 1500-3000 T5V300TW T5V300TW-4
400A 2000-4000 T5V400TW T5V400TW-4
T5-300/400A Frames, 100% Rated, Thermal-Magnetic Trip Unit
Breaker IC at
600VAC
Rating Magnetic
Trip
3-Pole, 600VAC/500VDC
Part Number
List
Price
T5N 18kA 300A 1500-3000 T5NQ300TW
400A 2000-4000 T5NQ400TW
T5S 25kA 300A 1500-3000 T5SQ300TW
400A 2000-4000 T5SQ400TW
T5H 35kA 300A 1500-3000 T5HQ300TW
400A 2000-4000 T5HQ400TW
T5L 65kA 300A 1500-3000 T5LQ300TW
400A 2000-4000 T5LQ400TW
T5V 100kA 300A 1500-3000 T5VQ300TW
400A 2000-4000 T5VQ400TW
(1) T5 600A not available with thermal-magnetic trip unit.
T5
ABB Discount Schedule DS-ST 27
AC1615S - 03/10
T5
400A / 600A
MCP (Instantaneous Only), Molded Case Switch
T5-300/400A Frame, Motor Control Protection (MCP) Electronic Trip Unit (Ac Only)
Breaker IC at
600VAC
Trip
Unit
Rating Adjustment
Range
3-Pole, 600VAC/600VDC
Part Number
List
Price
T5N 18kA PR221DS-I 300A 300-3000 T5N300E5W
400A 400-4000 T5N400E5W
T5S 25kA PR221DS-I 300A 300-3000 T5S300E5W
400A 400-4000 T5S400E5W
T5H 55kA PR221DS-I 300A 300-3000 T5H300E5W
400A 400-4000 T5H400E5W
T5L 65kA PR221DS-I 300A 300-3000 T5L300E5W
400A 400-4000 T5L400E5W
T5-600A Frame, Motor Control Protection (MCP) Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit
Rating Adjustment
Range
3-Pole, 600VAC/600VDC
Part Number
List
Price
T5N 18kA PR221DS-I 600A 600-6000 T5N600E5W
T5S 25kA PR221DS-I 600A 600-6000 T5S600E5W
T5H 55kA PR221DS-I 600A 600-6000 T5H600E5W
T5L 65kA PR221DS-I 600A 600-6000 T5L600E5W
T5-400/600A Frame, Molded Case Switch
Type IC at
600VAC Amps Magnetic
Trip
3-Pole, 600VAC/600VDC
Part Number
List
Price
4-Pole, 600VAC/600VDC
Part Number
List
Price
T5N-D 18kA 400 5000 T5N400DW
T5S-D 25kA 400 5000 T5S400DW
T5H-D 35kA 400 5000 T5H400DW T5H400DW-4
T5L-D 65kA 400 5000 T5L400DW
T5V-D 100kA 400 5000 T5V400DW
T5N-D 18kA 600 6000 T5N600DW
T5S-D 25kA 600 6000 T5S600DW
T5H-D 35kA 600 6000 T5H600DW
T5L-D 65kA 600 6000 T5L600DW
T5V-D 100kA 600 6000 T5V600DW
28 ABB
AC1615S - 03/10
T6
T6
600A / 800A, 600VAC
Electronic & Thermal-Magnetic
T6
General
The T6 breaker is an 800 amp frame with either a microprocessor based
over current protective trip system or a thermal magnetic trip unit. The T6 is
available as a 600 or 800A frame.
Standards
The UL489/CSA C22.2 No. 5 version of T6 also carries an IEC-60947-2 rating.
Versions
To meet all application requirements, the T6 is available in the following
versions:
T = Thermal-magnetic, xed
B = Selectable & adjustable LI or LS
C = Adjustable LSI
E = Adjustable LSIG
D = Molded Case Switch
E5 = Electronic instantaneous only (MCP)
Trip Functions
These trip functions are available:
L = Long time
S = Short time
I = Instantaneous
G = Ground fault
Performance Levels
Each version is also available in different maximum fault interrupting levels:
N = Normal
S = Standard
H = High
L = Extra high
Number of Poles (3)
The T6 is available as a 3 and 4 pole breaker.
4 poles only available in N or H version.
Reverse Feeding
All versions of the T6 family are suitable for reverse feed application.
Dimensions 3P Fixed Version 10.55H x 8.26W x
4.07D
Weight 20.9 (Ibs)
UL489 / CSA C22.2 Interrupting Capacity (kA RMS)
Voltage NSHL
240VAC 65 100 200 200
480VAC 35 50 65 100
600VAC 20 25 35 42
500VDC (1) 35 35 50 65
600VDC (2) 20 20 35 50
(1) 2 poles in series.
(2) 3 poles in series.
(3) 4 pole available N and H version only.
IEC 60947-2 Interrupting Capacity (kA RMS)
Voltage NSHL
230VAC 70 85 100 200
415VAC 36 50 70 100
600VAC 20 22 25 30
750VDC (2) 16 20 36 50
T6
ABB Discount Schedule DS-ST 29
AC1615S - 03/10
T6
600A / 800A, 600VAC
Electronic (AC Only)
T6-800A Frame, Electronic Trip Unit (AC Only) 320-800A Adjustable Range
Breaker IC at
600VAC
Trip
Unit
3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T6N 20kA
PR221 LS/I T6N800BW T6N800BW-4
PR222 LSI T6N800CW T6N800CW-4
PR222 LSIG T6N800EW T6N800EW-4
T6S 25kA
PR221 LS/I T6S800BW
PR222 LSI T6S800CW
PR222 LSIG T6S800EW
T6H 35kA
PR221 LS/I T6H800BW T6H800BW-4
PR222 LSI T6H800CW T6H800CW-4
PR222 LSIG T6H800EW T6H800EW-4
T6L 42kA
PR221 LS/I T6L800BW
PR222 LSI T6L800CW
PR222 LSIG T6L800EW
T6-600A Frame, Electronic Trip Unit (AC Only) 240-600A Adjustable Range
Breaker IC at
600VAC
Trip
Unit
3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T6N 20kA
PR221 LS/I T6N600BW T6N600BW-4
PR222 LSI T6N600CW T6N600CW-4
PR222 LSIG T6N600EW T6N600EW-4
T6S 25kA
PR221 LS/I T6S600BW
PR222 LSI T6S600CW
PR222 LSIG T6S600EW
T6H 35kA
PR221 LS/I T6H600BW T6H600BW-4
PR222 LSI T6H600CW T6H600CW-4
PR222 LSIG T6H600EW T6H600EW-4
T6L 42kA
PR221 LS/I T6L600BW
PR222 LSI T6L600CW
PR222 LSIG T6L600EW
Breaker IC at
600VAC
Trip
Unit
3-Pole, 600VAC
Part Number
List
Price
20kA
PR221 LS/I T6NQ600BW
T6N PR222 LSI T6NQ600CW
PR222 LSIG T6NQ600EW
25kA
PR221 LS/I T6SQ600BW
T6S PR222 LSI T6SQ600CW
PR222 LSIG T6SQ600EW
35kA
PR221 LS/I T6HQ600BW
T6H PR222 LSI T6HQ600CW
PR222 LSIG T6HQ600EW
42kA
PR221 LS/I T6LQ600BW
T6L PR222 LSI T6LQ600CW
PR222 LSIG T6LQ600EW
Breaker IC at
600VAC
Trip
Unit
3-Pole, 600VAC
Part Number
List
Price
20kA
PR221 LS/I T6NQ800BW
T6N PR222 LSI T6NQ800CW
PR222 LSIG T6NQ800EW
25kA
PR221 LS/I T6SQ800BW
T6S PR222 LS/I T6SQ800CW
PR222 LSIG T6SQ800EW
35kA
PR221 LS/I T6HQ800BW
T6H PR222 LSI T6HQ800CW
PR222 LSIG T6HQ800EW
42kA
PR221 LS/I T6LQ800BW
T6L PR222 LSI T6LQ800CW
PR222 LSIG T6LQ800EW
T6-800A Frame, 100% Rated Electronic Trip Unit (AC Only) 320-800A Adjustable Range
T6-600A Frame, 100% Rated Electronic Trip Unit (AC Only) 240-600A Adjustable Range
30 Discount Schedule DS-ST ABB
AC1615S - 03/10
T6
T6
600A / 800A, 600VAC
Electronic & Thermal-Magnetic
T6-600A Frame, Motor Control Protection (MCP) Electronic Trip Unit (AC
Only)
Breaker IC at
600VAC
Trip
Unit Adjustment Range 3-Pole, 600VAC
Part Number
List
Price
T6N 20kA PR221 DS-I 600-6000 T6N600E5W
T6S 25kA PR221 DS-I 600-6000 T6S600E5W
T6H 35kA PR221 DS-I 600-6000 T6H600E5W
T6L 42kA PR221 DS-I 600-6000 T6L600E5W
T6-800A Frame, Motor Control Protection (MCP) Electronic Trip Unit (AC
Only)
Breaker IC at
600VAC
Trip
Unit Adjustment Range 3-Pole, 600VAC
Part Number
List
Price
T6N 20kA PR221 DS-I 800-8000 T6N800E5W
T6S 25kA PR221 DS-I 800-8000 T6S800E5W
T6H 35kA PR221 DS-I 800-8000 T6H800E5W
T6L 42kA PR221 DS-I 800-8000 T6L800E5W
T6-800A Frame, Molded Case Switch
Breaker IC at
600VAC Amp Magnetic Trip 3-Pole, 600VAC/600VDC
Part Number
List
Price
4-Pole, 600VAC/600VDC
Part Number
List
Price
T6H 35kA 800 10,000 T6H800DW T6H800DW-4
T6-600/800A Frame, 100% Rated Thermal-Magnetic Trip Unit
Breaker IC at
600VAC Rating Magnetic Trip 3-Pole, 600VAC/600VDC
Part Number
List
Price
T6N 20kA 600A 3000 - 6000A T6NQ600TW
800A 4000 - 8000A T6NQ800TW
T6S 25kA 600A 3000 - 6000A T6SQ600TW
800A 4000 - 8000A T6SQ800TW
T6H 35kA 600A 3000 - 6000A T6HQ600TW
800A 4000 - 8000A T6HQ800TW
T6L 42kA 600A 3000 - 6000A T6LQ600TW
800A 4000 - 8000A T6LQ800TW
T6-600/800A Frame, Thermal-Magnetic Trip Unit
Breaker IC at
600VAC Rating Magnetic Trip 3-Pole, 600VAC/600VDC
Part Number
List
Price
4-Pole, 600VAC/600VDC
Part Number
List
Price
T6N 20kA 600A 3000 - 6000A T6N600TW T6N600TW-4
800A 4000 - 8000A T6N800TW T6N800TW-4
T6S 25kA 600A 3000 - 6000A T6S600TW
800A 4000 - 8000A T6S800TW
T6H 35kA 600A 3000 - 6000A T6H600TW T6H600TW-4
800A 4000 - 8000A T6H800TW T6H800TW-4
T6L 42kA 600A 3000 - 6000A T6L600TW
800A 4000 - 8000A T6L800TW
ABB 31
AC1615S - 03/10
T7
T7-T7M
1000A / 1200A, 600VAC
Electronic (AC Only)
T7
General
The T7 breaker is a 1200 amp frame with a microprocessor based over current
protective trip system.
Available in 2 versions: T7 for toggle operated, T7M for motor operated
Standards
The UL489/CSA C22.2 No. 5 version of T7 also carries an IEC-60947-2 rating.
Versions
To meet all application requirements, the T7 is available in the following
versions:
B = PR231-LS/I adjustable (dip switch)
C = PR232-LSI adjustable (dip switch)
E = PR331-LSIG adjustable (dip switch)
D = Moulded Case Switch
P = PR332-LI adjustable (keypad + LCD display)
R = PR332-LSI adjustable (keypad + LCD display)
S = PR332-LSIG adjustable (keypad + LCD display)
Trip Functions
These trip functions are available:
L = Long time
S = Short time
I = Instantaneous
G = Ground fault
Performance Levels
Each version is also available in different maximum fault interrupting levels:
S = Standard
H = High
L = Extra high
Number of Poles
The T7 is available as a 3 and 4 pole breaker.
Dimensions 3P Fixed Version 10.55H x 8.26W x 6.07D (1)
Weight 21.4 (Ibs)
UL489 / CSA C22.2 Interrupting Capacity (kA RMS)
Voltage SHL
240VAC 65 100 150
480VAC 50 65 100
600VAC 25 50 65
IEC 60947-2 Interrupting Capacity (kA RMS)
Voltage SHL
230VAC 85 100 200
415VAC 50 70 120
690VAC 30 42 50
(1) Toggle type (dimensions of toggle not included)
32 Discount Schedule DS-ST ABB
AC1615S - 03/10
T7
T7
1000A / 1200A, 600VAC
Electronic (AC Only)
T7S-1000A Frame, Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T7S 25kA
PR231/P LS/I T7S1000BW T7S1000BW-4
PR232/P LSI T7S1000CW T7S1000CW-4
PR331/P LSIG T7S1000EW T7S1000EW-4
PR332/P LI T7S1000PW T7S1000PW-4
PR332/P LSI T7S1000RW T7S1000RW-4
PR332/P LSIG T7S1000SW T7S1000SW-4
T7S-1200A Frame, Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T7S 25kA
PR231/P LS/I T7S1200BW T7S1200BW-4
PR232/P LSI T7S1200CW T7S1200CW-4
PR331/P LSIG T7S1200EW T7S1200EW-4
PR332/P LI T7S1200PW T7S1200PW-4
PR332/P LSI T7S1200RW T7S1200RW-4
PR332/P LSIG T7S1200SW T7S1200SW-4
T7H-1000A Frame, Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T7H 50kA
PR231/P LS/I T7H1000BW T7H1000BW-4
PR232/P LSI T7H1000CW T7H1000CW-4
PR331/P LSIG T7H1000EW T7H1000EW-4
PR332/P LI T7H1000PW T7H1000PW-4
PR332/P LSI T7H1000RW T7H1000RW-4
PR332/P LSIG T7H1000SW T7H1000SW-4
T7H-1200A Frame, Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T7H 50kA
PR231/P LS/I T7H1200BW T7H1200BW-4
PR232/P LSI T7H1200CW T7H1200CW-4
PR331/P LSIG T7H1200EW T7H1200EW-4
PR332/P LI T7H1200PW T7H1200PW-4
PR332/P LSI T7H1200RW T7H1200RW-4
PR332/P LSIG T7H1200SW T7H1200SW-4
T7L-1000A Frame, Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T7L 65kA
PR231/P LS/I T7L1000BW T7L1000BW-4
PR232/P LSI T7L1000CW T7L1000CW-4
PR331/P LSIG T7L1000EW T7L1000EW-4
PR332/P LI T7L1000PW T7L1000PW-4
PR332/P LSI T7L1000RW T7L1000RW-4
PR332/P LSIG T7L1000SW T7L1000SW-4
T7L-1200A Frame, Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T7L 65kA
PR231/P LS/I T7L1200BW T7L1200BW-4
PR232/P LSI T7L1200CW T7L1200CW-4
PR331/P LSIG T7L1200EW T7L1200EW-4
PR332/P LI T7L1200PW T7L1200PW-4
PR332/P LSI T7L1200RW T7L1200RW-4
PR332/P LSIG T7L1200SW T7L1200SW-4
T7
T7M
1000A / 1200A, 600VAC
Electronic (AC Only)
ABB Discount Schedule DS-ST 33
AC1615S - 03/10
T7MS-1000A Frame, Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T7MS 25kA
PR231/P LS/I T7MS1000BW T7MS1000BW-4
PR232/P LSI T7MS1000CW T7MS1000CW-4
PR331/P LSIG T7MS1000EW T7MS1000EW-4
PR332/P LI T7MS1000PW T7MS1000PW-4
PR332/P LSI T7MS1000RW T7MS1000RW-4
PR332/P LSIG T7MS1000SW T7MS1000SW-4
T7MS-1200A Frame, Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T7MS 25kA
PR231/P LS/I T7MS1200BW T7MS1200BW-4
PR232/P LSI T7MS1200CW T7MS1200CW-4
PR331/P LSIG T7MS1200EW T7MS1200EW-4
PR332/P LI T7MS1200PW T7MS1200PW-4
PR332/P LSI T7MS1200RW T7MS1200RW-4
PR332/P LSIG T7MS1200SW T7MS1200SW-4
T7MH, 1000A Frame, Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T7MH 50kA
PR231/P LS/I T7MH1000BW T7MH1000BW-4
PR232/P LSI T7MH1000CW T7MH1000CW-4
PR331/P LSIG T7MH1000EW T7MH1000EW-4
PR332/P LI T7MH1000PW T7MH1000PW-4
PR232/P LSI T7MH1000RW T7MH1000RW-4
PR332/P LSIG T7MH1000SW T7MH1000SW-4
T7MH-1200A Frame, Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T7MH 50kA
PR231/P LS/I T7MH1200BW T7MH1200BW-4
PR232/P LSI T7MH1200CW T7MH1200CW-4
PR331/P LSIG T7MH1200EW T7MH1200EW-4
PR332/P LI T7MH1200PW T7MH1200PW-4
PR332/P LSI T7MH1200RW T7MH1200RW-4
PR332/P LSIG T7MH1200SW T7MH1200SW-4
T7ML-1000A Frame, Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T7ML 65kA
PR231/P LS/I T7ML1000BW T7ML1000BW-4
PR232/P LSI T7ML1000CW T7ML1000CW-4
PR331/P LSIG T7ML1000EW T7ML1000EW-4
PR332/P LI T7ML1000PW T7ML1000PW-4
PR332/P LSI T7ML1000RW T7ML1000RW-4
PR332/P LSIG T7ML1000SW T7ML1000SW-4
T7ML-1200A Frame, Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T7ML 65kA
PR231/P LS/I T7ML1200BW T7ML1200BW-4
PR232/P LSI T7ML1200CW T7ML1200CW-4
PR331/P LSIG T7ML1200EW T7ML1200EW-4
PR332/P LI T7ML1200PW T7ML1200PW-4
PR332/P LSI T7ML1200RW T7ML1200RW-4
PR332/P LSIG T7ML1200SW T7ML1200SW-4
34 Discount Schedule DS-ST ABB
AC1615S - 03/10
T7
T7
1000A / 1200A, 600VAC
100% Rated Electronic (AC Only)
T7S-1000A Frame, 100% Rated Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
T7SQ 25kA
PR231/P LS/I T7SQ1000BW
PR232/P LSI T7SQ1000CW
PR331/P LSIG T7SQ1000EW
PR332/P LI T7SQ1000PW
PR332/P LSI T7SQ1000RW
PR332/P LSIG T7SQ1000SW
T7S-1200A Frame, 100% Rated Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
T7SQ 25kA
PR231/P LS/I T7SQ1200BW
PR232/P LSI T7SQ1200CW
PR331/P LSIG T7SQ1200EW
PR332/P LI T7SQ1200PW
PR332/P LSI T7SQ1200RW
PR332/P LSIG T7SQ1200SW
T7H-1000A Frame, 100% Rated Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
T7HQ 50kA
PR231/P LS/I T7HQ1000BW
PR232/P LSI T7HQ1000CW
PR331/P LSIG T7HQ1000EW
PR332/P LI T7HQ1000PW
PR332/P LSI T7HQ1000RW
PR332/P LSIG T7HQ1000SW
T7H-1200A Frame, 100% Rated Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
T7HQ 50kA
PR231/P LS/I T7HQ1200BW
PR232/P LSI T7HQ1200CW
PR331/P LSIG T7HQ1200EW
PR332/P LI T7HQ1200PW
PR332/P LSI T7HQ1200RW
PR332/P LSIG T7HQ1200SW
T7L-1000A Frame, 100% Rated Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
T7LQ 65kA
PR231/P LS/I T7LQ1000BW
PR232/P LSI T7LQ1000CW
PR331/P LSIG T7LQ1000EW
PR332/P LI T7LQ1000PW
PR332/P LSI T7LQ1000RW
PR332/P LSIG T7LQ1000SW
T7L-1200A Frame, 100% Rated Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
T7LQ 65kA
PR231/P LS/I T7LQ1200BW
PR232/P LSI T7LQ1200CW
PR331/P LSIG T7LQ1200EW
PR332/P LI T7LQ1200PW
PR332/P LSI T7LQ1200RW
PR332/P LSIG T7LQ1200SW
T7
T7M
1000A / 1200A, 600VAC
100% Rated Electronic (AC Only)
ABB Discount Schedule DS-ST 35
AC1615S - 03/10
T7MS-1000A Frame, 100% Rated Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
T7MSQ 25kA
PR231/P LS/I T7MSQ1000BW
PR232/P LSI T7MSQ1000CW
PR331/P LSIG T7MSQ1000EW
PR332/P LI T7MSQ1000PW
PR332/P LSI T7MSQ1000RW
PR332/P LSIG T7MSQ1000SW
T7MS-1200A Frame, 100% Rated Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
T7MSQ 25kA
PR231/P LS/I T7MSQ1200BW
PR232/P LSI T7MSQ1200CW
PR331/P LSIG T7MSQ1200EW
PR332/P LI T7MSQ1200PW
PR332/P LSI T7MSQ1200RW
PR332/P LSIG T7MSQ1200SW
T7MH-1000A Frame, 100% Rated Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
T7MHQ 50kA
PR231/P LS/I T7MHQ1000BW
PR232/P LSI T7MHQ1000CW
PR331/P LSIG T7MHQ1000EW
PR332/P LI T7MHQ1000PW
PR332/P LSI T7MHQ1000RW
PR332/P LSIG T7MHQ1000SW
T7MH-1200A Frame, 100% Rated Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
T7MHQ 50kA
PR231/P LS/I T7MHQ1200BW
PR232/P LSI T7MHQ1200CW
PR331/P LSIG T7MHQ1200EW
PR332/P LI T7MHQ1200PW
PR332/P LSI T7MHQ1200RW
PR332/P LSIG T7MHQ1200SW
T7ML-1000A Frame, 100% Rated Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
T7MLQ 65kA
PR231/P LS/I T7MLQ1000BW
PR232/P LSI T7MLQ1000CW
PR331/P LSIG T7MLQ1000EW
PR332/P LI T7MLQ1000PW
PR332/P LSI T7MLQ1000RW
PR332/P LSIG T7MLQ1000SW
T7ML-1200A Frame, 100% Rated Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
T7MLQ 65kA
PR231/P LS/I T7MLQ1200BW
PR232/P LSI T7MLQ1200CW
PR331/P LSIG T7MLQ1200EW
PR332/P LI T7MLQ1200PW
PR332/P LSI T7MLQ1200RW
PR332/P LSIG T7MLQ1200SW
36 Discount Schedule DS-ST ABB
AC1615S - 03/10
T7
T7-T7M
1000A / 1200A, 600VAC
MCP (Instantaneous Only), Molded Case Switch
Breaker IC at
600VAC Amps Trip
Unit
3-Pole, 600VAC
Part Number
List
Price
T7
25kA 1000 PR231/P-I T7S1000MW
50kA 1000 PR231/P-I T7H1000MW
65kA 1000 PR231/P-I T7L1000MW
25kA 1200 PR231/P-I T7S1200MW
50kA 1200 PR231/P-I T7H1200MW
65kA 1200 PR231/P-I T7L1200MW
Breaker IC at
600VAC Amps Trip
Unit
3-Pole, 600VAC
Part Number
List
Price
T7M
25kA 1000 PR231/P-I T7MS1000MW
50kA 1000 PR231/P-I T7MH1000MW
65kA 1000 PR231/P-I T7ML1000MW
25kA 1200 PR231/P-I T7MS1200MW
50kA 1200 PR231/P-I T7MH1200MW
65kA 1200 PR231/P-I T7ML1200MW
T7/T7M-1200A Frame, Molded Case Switch (AC Only)
Breaker IC at
600VAC Amps Magnetic
Trip
3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T7 50kA 1200 12000 T7H1200DW T7H1200DW-4
T7M 50kA 1200 12000 T7MH1200DW T7MH1200DW-4
T7-1000/1200A Frame, Motor Control Protection (MCP) Electronic Trip Unit (AC Only)
T7M-1000/1200A Frame, Motor Control Protection (MCP) Electronic Trip Unit (AC Only)
ABB Discount Schedule DS-STA 37
AC1615S - 03/10
T7
T7-T7M
1000A / 1200A, 600VAC
Accessories
Shunt Trips (YO)
Frame Size Voltage Part
Number
List
Price
T7 - T7M
415-440VAC KT7XS1
380-400VAC KT7XS2
240-250VAC/DC KT7XS3
220-240VAC/DC KT7XS4
120-127VAC/DC KT7XS5
110-120VAC/DC KT7XS6
60VAC/DC KT7XS7
48VAC/DC KT7XS8
30VAC/DC KT7XS9
24VAC/DC KT7XS0
Undervoltage Release - (UVR)
Frame Size Voltage Part
Number
List
Price
T7 - T7M
415-440VAC KT7XU1
380-400VAC KT7XU2
240-250VAC/DC KT7XU3
220-240VAC/DC KT7XU4
120-127VAC/DC KT7XU5
110-120VAC/DC KT7XU6
60VAC/DC KT7XU7
48VAC/DC KT7XU8
30VAC/DC KT7XU9
24VAC/DC KT7XU0
Shunt Closing Release (YC)
Frame Size Voltage Part
Number
List
Price
T7M
415-440VAC KT7MXC1
380-400VAC KT7MXC2
240-250VAC/DC KT7MXC3
220-240VAC/DC KT7MXC4
120-127VAC/DC KT7MXC5
110-120VAC/DC KT7MXC6
60VAC/DC KT7MXC7
48VAC/DC KT7MXC8
30VAC/DC KT7MXC9
24VAC/DC KT7MXC0
Auxiliary Contacts - (AUX)
Frame Size Type / Voltage Part
Number
List
Price
T7-T7M
1 AUX "C" + 1 BA "C" 400VAC
2 AUX "C" 400VAC
1 AUX "C" + 1 BA "C" 24VDC
2 AUX "C" 24VDC
1 S51"C" 250VAC
1 S51"C" 250VAC
KT7AS (1)
KT7XAS2
KT7ASL (1)
KT7XAS2L
KT7XS51
(2)
KT7S51
(1)
T7 X1 Shunt trip - UVR
(1) For installation on T7 only
(2) For installation on T7M only
Spring Charging Motor (M)
Frame Size Type / Voltage Part
Number
List
Price
T7M
380...415VAC KT7MXM2
220...250VAC/DC KT7MXM3
100/130VAC/DC KT7MXM5
48...60VAC/DC KT7MXM7
24...30VAC/DC KT7MXM9
Possible combinations are:
T7: a) 1 Aux + 1BA b) 2 Aux,
c) 3 Aux + 1BA
T7M: a) 2 Aux , b) 4 Aux
38 Discount Schedule DS-STA ABB
AC1615S - 03/10
T7
Terminal Covers for Fixed Breakers - Low Pro le-Kit Includes Two Pieces
Frame Part Number
(3-Pole)
List
Price
Part Number
(4-Pole)
List
Price
T7-T7M KT7XLTC-3 KT7XLTC-4
Terminal Covers for Fixed Breakers - High Pro le-Kit Includes Two Pieces
Frame Part Number
(3-Pole)
List
Price
Part Number
(4-Pole)
List
Price
T7-T7M KT7XHTC-3 KT7XHTC-4
Phase Barriers - Low Pro le - 100mm - 3.93 in
Frame Part Number
(3-Pole)
List
Price
Part Number
(4-Pole)
List
Price
T7-T7M KT7PBL-3 KT7PBL-4
Phase Barriers - High Pro le - 200mm - 7.87 in
Frame Part Number
(3-Pole)
List
Price
Part Number
(4-Pole)
List
Price
T7-T7M KT7PBH-3 KT7PBH-4
Extended Front Terminals - IEC
Frame Part Number
(3-Pole)
List
Price
Part Number
(4-Pole)
List
Price
T7-T7M KT7EF-3 KT7EF-4
Rear Terminals - IEC
Frame Part Number
(set of 3)
List
Price
Part Number
(set of 4)
List
Price
T7-T7M KT7XR-3 KT7XR-4
Variable Depth Handle Operators
Frame Mechanism
Part Number
List
Price Shaft Part Number List
Price
Handle
Part Number
List
Price
T7 KT7VD-M OXP10X500 (19.7”)
OHB175J10X
OHY175J10
OHB175L10
KT7VD-S (19.7”) KT7VD-H
Direct Mount Rotary Operator Handle
Frame Breaker Mounting Part Number List Price
T7 Fixed, Plug-In KT7RH
Early Make Contact
Frame Part Number List Price
T7 KT7EM
Padlock Locking Device
Frame Style Locking Position Breaker Mounting Part Number List
Price
T7 PLL OPEN Fixed, Drawout
KT7LDO
T7M PLL OPEN Fixed, Draw-out
KT7MLDO
Keylocks for the Rotary Handle Mechanism
Frame Style Locking Position Keys Part Number List
Price
T7
KLF-D OPEN Different
KT7KLFD
KLF-S OPEN Same key # 20005
KT7KLFS-20005
KLF-S OPEN Same key # 20006
KT7KLFS-20006
KLF-S OPEN Same key # 20007
KT7KLFS-20007
KLF-S OPEN Same key # 20008
KT7KLFS-20008
Keylocks on the Circuit-Breaker
Frame Style Locking Position Keys Part Number List
Price
T7
KLF-D OPEN Different
KT7KLCD
KLF-S OPEN Same key # 20005
KT7KLCS-20005
KLF-S OPEN Same key # 20006
KT7KLCS-20006
KLF-S OPEN Same key # 20007
KT7KLCS-20007
KLF-S OPEN Same key # 20008
KT7KLCS-20008
T7M
KLF-D OPEN Different
KT7MKLCD
KLF-S OPEN Same key # 20005
KT7MKLCS-20005
KLF-S OPEN Same key # 20006
KT7MKLCS-20006
KLF-S OPEN Same key # 20007
KT7MKLCS-20007
KLF-S OPEN Same key # 20008
KT7MKLCS-20008
T7-T7M
1000A / 1200A, 600VAC
Accessories
(1) Comes standard with high pro le terminal covers.
Standard Cable Terminal (1)
Frame Wire Size Part Number
(set of 3)
List
Price
Part Number
(set of 4)
List
Price
T7-T7M 1(4) 4/0-500 kcmil KT7X1200-3 KT7X1200-4
ABB Discount Schedule DS-STA 39
AC1615S - 03/10
Neutral Current Transformers (Required for 4-Wire Ground Fault System)
Frame Part
Number
List
Price
T7 400...1200A KT7XNCT1200
Rating Plugs
Frame Rating Plug Part
Number
List
Price
T7
400A
600A
800A
1000A
1200A
KT70400RP
KT70600RP
KT70800RP
KT71000RP
KT71200RP
Mechanical Accessories
Item Part
Number
List
Price
Flange T7 KT7XFCD
Mech. operation
counter KT7XEMC
IP54 door cover KT7XDC
Draw-Out Kits
Item Part Number
Adaptor Moving Part
List
Price
Part Number
Fixed Part
List
Price
T7 - 3 pole with RC-RC KT7WMK KT7WFRC
T7 - 4 pole with RC-RC KT7WMK-4 KT7WFRC-4
Sliding Contact Blocks — T7-Draw-Out (1)
Item Moving Part
Breaker
List
Price
Fixed Part
Cradle
List
Price
Left Block
KT7XSCMP-L
KT7SCFP-L (T7)
KT7MXSCFP-L
(T7M)
Spring charging motor
Spring charged contact
Ready to close contact
Early auxiliary contact
Contact for trip coil release trip
Trip rest
Center Block
KT7XSCMP-C KT7XSCFP-CPR331
PR332
Right Block
KT7XSCMP-R KT7XSCFP-R
Auxiliary contacts
Shunt trip
Closing Coil
Undervoltage release
Position Key Lock (Fixed Part) — T7 - T7M
Item Part
Number
List
Price
Different key KT7XPL-D
Same key #20005 KT7XPL-20005
Same key #20006 KT7XPL-20006
Same key #20007 KT7XPL-20007
Same key #20008 KT7XPL-20008
Locks drawout breaker in racked-in / test isolation / racked-out position.
Position Key Lock Accessory (Fixed Part) — T7 - T7M
Item Part
Number
List
Price
Key lock accessory KT7XPLA
Accessory added to position key lock allows breaker to be locked in racked-out position only.
Mechanical Interlocks
Item Part
Number
List
Price
T7 (2)
Cable T7 KT7XMLC
Mech. interlock plate- xed KT7XMLPW
Mech. interlock plate-draw-out KT7XMLPF
T7-T7M
1000A / 1200A, 600VAC
Accessories
(1) If at least one of the accessories in table is installed on the breaker - respective pair of contact blocks must be installed on the xed
part (cradle) and the moving part. (breaker)
(2) To interlock two circuit breakers, you have to order a cable kit and two plates.
T7
40 ABB
AC1615S - 03/10
(1) Fixed part and accessories to be ordered separately
T7
T7 / T7M
1000A / 1200A, 600VAC
Part-Numbering System
Locking Provisions:
X = None, A = Keylock,
B = Button guard,
C = Padlock Provision (open),
D = Withdrawable Position
Lock (Connected, test and
disconnected positions),
E = Withdrawable Position
Lock (Test and
disconnected positions)
Accessories
X = None,
A = Mechanical counter
Undervoltage:
0 = None, A = 24VAC/DC, B = 30VAC/DC,
C = 48VAC/DC, D = 60VAC/DC,
E = 110..120VAC/DC, F = 120..127VAC/DC,
G = 220..240VAC/DC, H = 240..250VAC/DC,
J = 380..400VAC, K = 415..440VAC
Closing Coil:
0 = None, A = 24VAC/DC, B = 30VAC/DC, C = 48VAC/DC,
D = 60VAC/DC, E = 110..120VAC/DC, F = 120..127VAC/DC,
G = 220..240VAC/DC, H = 240..250VAC/DC,
J = 380..400VAC, K = 415..440VAC
Shunt Trip:
0 = None, A = 24VAC/DC, B = 30VAC/DC, C = 48VAC/DC,
D = 60VAC/DC, E = 110..120VAC/DC, F = 120..127VAC/DC,
G = 220..240VAC/DC, H = 240..250VAC/DC,
J = 380..400VAC, K = 415..440VAC
Spring Charging Motor:
0 = None, A = 24..30VAC/DC, B = 48..60VAC/DC,
C = 100..130VAC/DC, D = 220..250VAC/DC,
E = 380..415VAC/DC
Aux Contacts:
0 = None, A = 1 Form C + 1BA 400VAC (T7), B = 1 Form C + 1BA 24VDC (T7),
C = 2 Form C 400VAC (T7-T7M), D = 2 Form C 24VDC (T7-T7M), E = S51 250VAC (T7),
F = S51 250VAC (T7M), G = A+C (T7), H = B+D (T7), I = C+E (T7), J = C+F (T7M),
K = D+E (T7), L = D+F (T7M), M = C+C (T7M), N = D+D (T7M)
Trip Unit Accessories:
0 = None, A = PR330V, B = PR330/D-M, C = A + B
Trip Unit:
X = Non-Automatic (MCS), B = PR231/P-LS/I, C = PR232/P-LSI, E = PR331/P-LSIG,
P = PR332/P-LI, R = PR332/P-LSI, S = PR332/P-LSIG
Rating Plug:
0 = None Non-Automatic (MCS), A = 400, B = 600, C = 800, D = 1000A, E = 1200
Frame Amp Rating:
1 = 1000A (toggle) 2 = 1200A (toggle) P =1000A (motorized) B =1200A (motorized)
Version:
B = UL Fixed, Q = UL Fixed 100% Rated, 0 = Fixed Non-Automatic (MCS)
W = UL Draw-out1, X = UL Draw-out 100%1, Y = Draw-out non-automatic (1)
Breaking Capacity
S, H, L
T7
ABB 41
AC1615S - 03/10
T8
T8V
1600A / 2000A / 2500A / 3000A
Insulated Case Circuit Breaker
Dimensions 3P Version: 15.00" H x 16.8" W x 11.2"D
Weight 161 (lbs) 1600A/2000A/2500A
236 (lbs) 3000A
T8V
The Tmax family, conforming to the UL489 and CSA C22.2 No. 5.0 Standards, is enriched
with the TmaxT8 size, which allows 3000 A to be reached. Also avai-
lable in the 1600A, 2000A and 2500A frames, Tmax T8 is equipped with the same electronic
trip units as Tmax T7 thereby guaranteeing extremely high perfor-
mances able to satisfy all installation requirements. Tmax T8 is able to interrupt the following
short-circuit currents: 125kA@480VAC and 100kA@600 VAC.
Available in 3 and 4 pole versions
Four different frame ratings, 1600, 2000, 2500 & 3000 Amps
Available 100% rated version up to 3000A
Installation in vertical position only
Wide range of CSA/UL eld-installable accessories
Solid state trip unit available in three different versions:
- PR331/P-LSI
- PR331/P-LSIG
- PR332/P-LI (LCD display)
- PR332/P-LSI (LCD display)
- PR332/P-LSIG (LCD display)
The ability to add internal modules for exible and precise con guration:
Optional modules includes:
- Voltage module
- Signaling module
- Communications module
UL489 / CSA C22.2 Interrupting Capacity (kA RMS)
Voltage V
240VAC 125
480VAC 125
600VAC 100
IEC 60947-2 Interrupting Capacity (kA RMS)
Voltage V
230VAC 130
415VAC 130
440VAC 130
500VAC 100
600VAC 80
42 Discount Schedule DS-ST8 ABB
AC1615S - 03/10
T8
T8V
1600A / 2000A / 2500A / 3000A, 600VAC
Electronic (AC Only)
T8-1600A Frame, Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T8V 100kA
PR331/P LSI T8V16CW T8V16CW-4
PR331/P LSIG T8V16EW T8V16EW-4
PR332/P LI T8V16PW T8V16PW-4
PR332/P LSI T8V16RW T8V16RW-4
PR332/P LSIG T8V16SW T8V16SW-4
T8-2000A Frame, Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T8V 100kA
PR331/P LSI T8V20CW T8V20CW-4
PR331/P LSIG T8V20EW T8V20EW-4
PR332/P LI T8V20PW T8V20PW-4
PR332/P LSI T8V20RW T8V20RW-4
PR332/P LSIG T8V20SW T8V20SW-4
T8-2500A Frame, Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T8V 100kA
PR331/P LSI T8V25CW T8V25CW-4
PR331/P LSIG T8V25EW T8V25EW-4
PR332/P LI T8V25PW T8V25PW-4
PR332/P LSI T8V25RW T8V25RW-4
PR332/P LSIG T8V25SW T8V25SW-4
T8-3000A Frame, Electronic Trip Unit (AC Only)1
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T8V 100kA
PR331/P LSI T8V30CW T8V30CW-4
PR331/P LSIG T8V30EW T8V30EW-4
PR332/P LI T8V30PW T8V30PW-4
PR332/P LSI T8V30RW T8V30RW-4
PR332/P LSIG T8V30SW T8V30SW-4
T8-3000A Frame, Molded Case Switch (AC Only)1
Breaker Rating Magnetic Override 3-Pole, 600VAC
Part Number
List
Price
4-Pole, 600VAC
Part Number
List
Price
T8V-D
2000A
40000A
T8V20DW T8V20DW-4
2500A T8V25DW T8V25DW-4
13000A (1) T8V30DW T8V30DW-4
(1) Vertical terminals only
ABB Discount Schedule DS-ST8 43
AC1615S - 03/10
T8
T8V
1600A / 2000A / 2500A / 3000A, 600VAC
100% Rated Electronic (AC Only)
T8-1600A Frame, 100% Rated Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
T8VQ 100kA
PR331/P LSI T8VQ16CW
PR331/P LSIG T8VQ16EW
PR332/P LI T8VQ16PW
PR332/P LSI T8VQ16RW
PR332/P LSIG T8VQ16SW
T8-2000A Frame, 100% Rated Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
T8VQ 100kA
PR331/P LSI T8VQ20CW
PR331/P LSIG T8VQ20EW
PR332/P LI T8VQ20PW
PR332/P LSI T8VQ20RW
PR332/P LSIG T8VQ20SW
T8-2500A Frame, 100% Rated Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
T8VQ 100kA
PR331/P LSI T8VQ25CW
PR331/P LSIG T8VQ25EW
PR332/P LI T8VQ25PW
PR332/P LSI T8VQ25RW
PR332/P LSIG T8VQ25SW
Note: vertical terminals only
T8-3000A Frame, 100% Rated Electronic Trip Unit (AC Only)
Breaker IC at
600VAC
Trip
Unit Adjustment 3-Pole, 600VAC
Part Number
List
Price
T8VQ 100kA
PR331/P LSI T8VQ30CW
PR331/P LSIG T8VQ30EW
PR332/P LI T8VQ30PW
PR332/P LSI T8VQ30RW
PR332/P LSIG T8VQ30SW
Note: vertical terminals only
44 Discount Schedule DS-ST8 ABB
AC1615S - 03/10
T8
T8V
1600A / 2000A / 2500A / 3000A, 600VAC
Accessories
Shunt Trips (YO) and Closing Coils (YC)
Frame Size Voltage YO
Part Number
List
Price
YC
Part Number
List
Price
T8
24VDC KT8ES0 KT8EC0
30VAC/DC KT8ES9 KT8EC9
48VAC/DC KT8ES8 KT8EC8
60VAC/DC KT8ES7 KT8EC7
110/120VAC/DC KT8ES6 KT8EC6
120/127VAC/DC KT8ES5 KT8EC5
220/240VAC/DC KT8ES4 KT8EC4
250VAC/DC KT8ES3 KT8EC3
380/400VAC KT8ES2 KT8EC2
440/480VAC KT8ES1 KT8EC1
Undervoltage Release (UVR) or Additional Shunt Trip (YO2)
Frame Size Voltage YO
Part Number
List
Price
YC
Part Number
List
Price
T8
24VDC KT8EU0 KT8ES0-2
30VAC/DC KT8EU9 KT8ES9-2
48VAC/DC KT8EU8 KT8ES8-2
60VAC/DC KT8EU7 KT8ES7-2
110/120VAC/DC KT8EU6 KT8ES6-2
120/127VAC/DC KT8EU5 KT8ES5-2
220/240VAC/DC KT8EU4 KT8ES4-2
250VAC/DC KT8EU3 KT8ES3-2
380/400VAC KT8EU2 KT8ES2-2
440/480VAC KT8EU1 KT8ES1-2
Note: UVR and YO2 are mutually exclusive (only one device can be installed)
Signaling Contacts
Frame Size Voltage Part
Number
List
Price
T8
4 aux. cont. open/close PR331 KT8AS4
4 aux. cont. open/close PR332 KT8AS4-332
4 aux. cont. open/close for PR232-331 (low power <24V) KT8AS4L
4 aux. cont. open/close for PR332 (low power <24V) KT8AS4L-332
BA - bell alarm contact ( 1 form "c") KT8ETBA
BA + remote reset 24…30VAC/DC KT8ETBAR9
BA + remote reset 110…130VAC/DC KT8ETBAR5
BA + remote reset 220…240VAC/DC KT8ETBAR4
UVR de-energized contact - NC KT8EUE10
UVR de-energized contact - NO KT8EUE01
1SDC200131F0001
1SDC200132F00011SDC200139F00011SDC200145F0001
Stored Energy Motor (M)
Frame Size Voltage Part
Number
List
Price
T8
24/30VAC/DC KT8EM9
48/60VAC/DC KT8EM7
100/130VAC/DC KT8EM5
220/250VAC/DC KT8EM3
Note: 4 aux. cont. open/close supplied as standard with PR332 trip unit
ABB Discount Schedule DS-ST8 45
AC1615S - 03/10
T8
T8V
1600A / 2000A / 2500A / 3000A, 600VAC
Accessories
Locking Devices
Frame Size Description Part
Number
List
Price
T8
Key lock open position - different keys KT8KL-D
Key lock open position - same key no. 20005 KT8KL-20005
Key lock open position - same key no. 20006 KT8KL-20006
Key lock open position - same key no. 20007 KT8KL-20007
Key lock open position - same key no. 20008 KT8KL-20008
Padlock device in open position KT8EPD1
Padlock device in open position (HD) KT8EPDHD1
Pushbuttons protection KT8EPG
Note: KT8EPD1/KT8EPDHD1 are mutually exclusive with KT8EPG
Connection Accessories
Frame Size Description Part
Number
List
Price
T8
Cable terminals 1600A (1/0 - 750MCM - kit of 3 K8TL
Cable terminals 2500A (1/0 - 750MCM) - kit of 3 K8TM
Rear T terminal (2500A max.) - kit of 6 KT8VR2500
Rear T terminal (2500A max.) - kit of 8 KT8VR2500-4
Note: K8TL/K8TM requires the installation of KT8PBH-3
Mechanical Accessories
Frame Size Description Part
Number
List
Price
T8
Door ange KT8FCD
IP54 protection cover (NEMA 3S/13) KT8EDC
Separating partition low PB100 3 pole - 2pcs KT8PBL-3
Separating partition low PB100 4 pole - 3pcs KT8PBL-4
Separating partition high PB200 3 pole - 2pcs KT8PBH-3
Separating partition high PB200 4 pole - 2pcs KT8PBH-4
Mechanical operation counter KT8EMC
Accessories for Trip Units
Frame Size Description Part
Number
List
Price
T8
Rating plug In=1000A KT81000RP
Rating plug In=1200A KT81200RP
RatIng plug In=1600A KT81600RP
RatIng plug In=2000A KT82000RP
RatIng plug In=2500A KT82500RP
RatIng plug In=3000A KT83000RP
PR330/V for PR332/P 3 pole (voltage measurement) KT8PR330V-3
PR330/V for PR332/P 4 pole (voltage measurement) KT8PR330V-4
PR330/D-M for PR332/P (MODBUS RTU communication) KT8330DMOD
PR030B - Battery power supply unit KT8EPR030B
Current Sensor for External Neutral
Frame Size Description Part
Number
List
Price
T8 Current sensor neutral In=1000-3000A KT8NCT-3000
1SDC200158F0001
1SDC200157F0001
1SDC200166F0001
46 ABB
AC1615S - 03/10
T8
T8V
1600A / 2000A / 2500A / 3000A, 600VAC
Part-Numbering System
Accessories
X = None
A = Mechanical counter
B = Bell Alarm
C = Bell Alarm w/remote reset 24..30VAC/DC
D = Bell Alarm w/remote reset 110..130VAC/DC
E = Bell Alarm w/remote reset 220..240VAC/DC
F = A+B
G = A+C
H = A+D
J = A+E
Shunt Trip:
0 = none
A = 24VDC
B = 30VAC/DC
C = 48VAC/DC
D = 60VAC/DC
E = 110..120VAC/DC
F = 120..127VAC/DC
G = 220..240VAC/DC
H = 240..250VAC/DC
J = 380400VAC
K = 440VAC
Contacts1:
0 = None
A = 4 aux contacts D = UVR De-Energized NC G = B + E
B = 4 aux. contacts digital (24V) E = A + D
C = UVR De-Energized NO F = A + E
Spring Charging Motor:
0 = None
A = 24..30VAC/DC
B = 48..60VAC/DC
C = 100..130VAC/DC
D = 220..250VAC/DC
Closing Coil:
0 = None
A = 24VDC
B = 30VAC/DC
C = 48VAC/DC
D = 60VAC/DC
E = 110..120VAC/DC
F = 120..127VAC/DC
G = 220..240VAC/DC
H = 240..250VAC/DC
J = 380..400VAC
K = 440VAC
Trip Unit Accessories PR332/P only:
0 = None
B = Voltage measuring module
C = Modbus module
Trip Unit:
C = PR331/P-LSI
D = Non-Automatic (MCS)
E = PR331/P-LSIG
P = PR332/P-LI
R = PR332/P-LSI
S = PR332/P-LSIG
Rating Plug:
D = 1000
E = 1200
F = 1600
G = 2000
H = 2500
J = 3000
Frame Amp Rating:
C = 1600 (3P)
D = 2000 (3P)
E = 2500 (3P)
F = 3000 (3P)
G = 1600 (4P)
H = 2000(4P)
J = 2500 (4P)
K = 3000 (4P)
Version:
B = UL Fixed 80% rated Q = UL Fixed 100% Rated 0 = Fixed Non-Automatic (MCS)
Breaking Capacity
V (T8 UL)
T8V
Undervoltage:
0 = None
A = 24VDC
B = 30VAC/DC
C = 48VAC/DC
D = 60VAC/DC
E = 110..120VAC/DC
F = 120..127VAC/DC
G = 220..240VAC/DC
H = 240..250VAC/DC
J = 380..400VAC
J = 440 VAC
Second shunt trip:
L = 24VDC
M = 30
VAC/DC
N = 48
VAC/DC
P = 60
VAC/DC
Q = 110..120
VAC/DC
R = 120..127
VAC/DC
S = 220..240
VAC/DC
T = 240..250
VAC/DC
U = 380..400VAC
V = 440..480 VAC
Locking Provisions:
A = Keylock
B = Button guard
C = Padlock Provision
D = A+B
E = A+C
X = None
0 = Non-Automatic (MCS)
1 4 Aux. contacts supplied as standard with PR332.
ABB Discount Schedule DS-STA 47
AC1615S - 03/10
Acc.
Accessories
Electrical
T1-T6
KT3S4
(1) Add suf x to circuit breaker part number. See p.4 for more details.
(2) Must be ordered separately for eld installation.
T1 with KT3S4
Shunt Trips (Standard)(1)
For remote opening of circuit breaker. Guaranteed operation for a voltage of between 75-110%
of the rated power supply voltage. T1-T6 mounts in the left hand cavity cannot be used with UVR on 2-3P breakers
Factory Installation (1) Field Installation
Frame Size Voltage Part Number
Suf x
List Price
Adder
Part
Number
List
Price
T1-T2-T3
480 - 500VAC S1 KT3S1
220-250VAC/DC S2 KT3S2
380 - 440VAC S3 KT3S3
110 - 125VAC/DC S4 KT3S4
48 - 60VAC/DC S7 KT3S7
24 - 30VAC/DC S8 KT3S8
12VDC S9 KT3S9
Ts3
480VAC/250VDC S1 KTs3S1
240 VAC S2 KTs3S2
120VAC/125VDC S4 KTs3S4
48VDC S7 KTs3S7
24VAC/VDC S8 KTs3S8
12VDC S9 KTs3S9
T4-T5-T6
480-500VAC S1 KT6S1
220/250VAC/DC S2 KT6S2
380-440VAC S3 KT6S3
110-125VAC/DC S4 KT6S4
48-60VAC/DC S7 KT6S7
24VAC/DC S8 KT6S8
12VDC S9 KT6S9
Shunt Trips (Permanent Supply)(1)
For remote opening of circuit breaker. Guaranteed operation for a voltage of between 75-110% of the rated power supply voltage.
These shunt trips have much lower power consumption.
Factory Installation (1) Field Installation
Frame Size Voltage Part Number
Suf x
List Price
Adder
Part
Number
List
Price
Ts3 24VDC SA KTs3SP4
120VAC SB KTs3SP8
T4-T5-T6 24-30VDC SP4 KT6SP4
110/120/VAC SP8 KT6SP8
Shunt Trip Connector (Required for Ts3) (2)
Ts3 Fixed Mount Not required for factory installed KTs3C-SU
Draw-out Not required for factory installed KTs3C-SUP
48 Discount Schedule DS-STA ABB
AC1615S - 03/10
Acc.
Accessories
Electrical
T1-T6
KT3U2
Undervoltage Release - UVR
Will trip circuit breaker when connected voltage drops to 35-70% of the undervoltage release
voltage rating. Will allow circuit breaker to close when voltage is approximately 85% of the
rated voltage. T1-T6 mounts in the left hand cavity cannot be used with shunt trip on 2-3P breakers
Factory Installation (1) Field Installation
Frame Size Voltage Part Number
Suf x
List Price
Adder
Part
Number
List
Price
T1-T2-T3
480 - 500VAC U1 KT3U1
220-250VAC/DC U2 KT3U2
380 - 440VAC U3 KT3U3
110 - 125VAC/DC U4 KT3U4
60VAC/DC U5 KT3U5
48VAC/DC U7 KT3U7
24 - 30VAC/DC U8 KT3U8
Ts3
480VAC U1 KTs3U1
240VAC U2 KTs3U2
24VAC U3 KTs3U3
120VAC U4 KTs3U4
250VDC U5 KTs3U5
125VDC U6 KTs3U6
48VDC U7 KTs3U7
24VDC U8 KTs3U8
T4-T5-T6
480-500VAC U1 KT6U1
220/250VAC/DC U2 KT6U2
380-440VAC U3 KT6U3
110-125VAC/DC U4 KT6U4
60VAC/DC U5 KT6U5
48VAC/DC U7 KT6U7
24VAC/DC U8 KT6U8
Undervoltage Trip Connector (Required for Ts3) (2)
Ts3 Fixed Mount Not required for factory installed KTs3C-SU
Plug-In/Draw-out Not required for factory installed KTs3C-SUP
(1) Add suf x to circuit breaker part number. See p.4 for more details.
(2) Must be ordered separately for eld installation.
ABB Discount Schedule DS-STA 49
AC1615S - 03/10
Acc.
Accessories
Electrical
T1-T6
KTs3AS
T1 with K3TAS
Auxiliary Contacts - AUX (1)
Auxiliary contacts are for indication of the circuit breaker open-closed. Bell alarm contacts (BA) can be
used to indicate circuit breaker tripped.
Frame Size
Factory Installation Field Installation
Part Number
Suf x
List Price
Adder
Part
Number
List
Price
T1-T2-T3 (2)
1 AUX "C" + 1 BA "C" 250VAC/DC
A KT3AS
3 AUX "C" + 1 BA "C" 250VAC/DC
A3 KT3AS3
T2 (3)
2 AUX "C" + 1 BA "C" PR221DS
AE KT2AS-E
1 AUX "C" + 1 BA "C" + 1S51 "C" PR221DS
AE2 KT2AS-E2
Ts3
2 AUX "C" 250VAC/DC
A KTs3AS
1 AUX "C" + 1 BA "C" 250VAC/DC
BA KTs3BA
T4-T5-T6
1 AUX "C" + 1 BA "C" 250VAC/DC
A KT6AS
2 AUX "C" 400VAC
A2 KT6AS2
3 AUX "C" + 1 BA "C" 250VAC/DC
A3 KT6AS3
3 AUX "C" + 1 BA "C" 24VDC
A3L KT6AS3L
Auxiliary Contact Connector (Required for Ts3) (4)
Ts3 Fixed Not required for factory installed
Not required for factory installed
KTs3C-AB
Plug-In /Drawout KTs3C-ABP
(1) Add suf x to circuit breaker part number. See p.4 for more details.
(2) Not compatible for T2 with PR221DS trip unit.
(3) For installation on T2 with PR221DS electronic trip unit
(4) Must be ordered separately for eld installation.
50 Discount Schedule DS-STA ABB
AC1615S - 03/10
Acc.
Accessories
Motor Operators
T1-T6
KT3M1
KTS3M2
KT5M2
Electrical Operators
Allows remote opening and closing of circuit breaker
Frame Size Voltage Part
Number
List
Price
Solenoid Operator
T1-T2-T3 48 - 60VDC KT3M1
110 - 250VAC/DC KT3M2
Direct Action Motor Operator
Ts3
240VAC/250VDC KTs3M2
120VAC/125VDC KTs3M4
48VDC KTs3M7
24VDC KTs3M8
Motor Operator Connector (Required for Ts3) (1)
Ts3 Fixed Mount KTS3C-M
Plug-In / Draw-out KTS3C-MP
Stored Energy Motor Operator
T4-T5
220-250VAC/DC KT5M2
110--125-VAC/DC KT5M4
48-60VDC KT5M7
24VDC KT5M8
380VAC KT5M3
Stored Energy Motor Operator
T6
220-250VAC/DC KT6M2
110--125-VAC/DC KT6M4
48-60VDC KT6M7
24VDC KT6M8
380VAC KT6M3
Stored Energy Motor With Communication (IEC)
T4-T5
220-250VAC/DC KT5M2-E
380VAC KT5M3-E
110-125VAC/DC KT5M4-E
48-60VDC KT5M7-E
24VDC KT5M8-E
T6
220-250VAC/DC KT6M2-E
380VAC KT6M3-E
110-125VAC/DC KT6M4-E
48-60VDC KT6M7-E
24VDC KT6M8-E
Dry Contact for Remote/Manual Operation
T4-T5-T6 - KT6MA
(1) Must be ordered separately for eld installation
ABB Discount Schedule DS-STA 51
AC1615S - 03/10
Acc.
Accessories
Trip Units
Neutral Current Transformers (Required for 4-Wire Ground Fault Systems)
Frame Size Part
Number
List
Price
T4
100A KT4NCT-100
150A KT4NCT-150
250A KT4NCT-250
T5
300A KT5NCT-300
400A KT5NCT-400
600A KT5NCT-600
T6 600A
800A
KT6NCT-600
KT6NCT-800
Note: X4 connector required for T4 - T5 - T6
Front Display Unit
Used with
High Pro le Cover
List
Price
T4-T5 with PR222DS/P or PR2222DS/PD KT5FDU
T6
with PR222DS/P or PR222DS/PD KT6FDU
Connector for PR222DS
Fixed Circuit-Breaker Plug-in or Draw-Out Circuit-Breaker
T4-T5-T6 Part
Number
List
Price
Part
Number
List
Price
X3 Connector KT6CX3 KT6CX3-P
X4 Connector KT6CX4 KT6CX4-P
KT5FDU
52 ABB
AC1615S - 03/10
Acc. Technical Data
Shunt Trips/Undervoltages
Standard Shunt Trip
Voltage
Inrush Power Consumption
T1,T2,T3 Ts3 T4,T5,T6 T7
AC (VA) DC (W) AC (VA) DC (W) AC (VA) DC (W) AC (VA) DC (W)
12 VDC - 50 - 120 - 150 - -
24 VAC/DC - - 100 100 or 4 (1) - - 300 300
24…30 VAC/DC 50 50 - - 150 150 - -
30 VAC/DC - - - - - - 300 300
48 VAC/DC - - - 120 - - 300 300
48…60 VAC/DC 60 60 - - 150 150 - -
60 VAC/DC ------300300
100…120 VAC/DC - - 100 or 4 (1) - - - 300 300
120…127 VAC/DC - - - - - - 300 300
110…127 VAC 110…125 VDC 50 50 - 120 150 150 - -
220…240 VAC/DC - - - - - - 300 300
220…240 VAC 220…250 VDC 50 50 100 120 150 150 - -
240…250 VAC/DC - - - - - - 300 300
380…400 VAC - - - - - - 300 -
380…440 VAC 55 - - - 150 - - -
415…440 VAC - - ----300-
480 VAC - - 100 - - - - -
480…525 VAC 55 - - - 150 - - -
Opening Time (ms) 15 15 15 15 15 15 20 20
Permanent Supply Shunt Trip
Voltage T4,T5,T6
AC (VA) DC (W)
24 VAC/DC 4 4
100…120 VAC 4 -
Undervoltage
Voltage
Power Consumption During Permanent Operation
T1,T2,T3 Ts3 T4, T5, T6 T7
AC (VA) DC (W) AC (VA) DC (W) AC (VA) DC (W) AC (VA) DC (W)
24 VAC/DC - - 6 3 - - 3.5 3.5
24…30 VAC/DC 1.5 1.5 - - 6 3 - -
30 VAC/DC ------3.53.5
48 VAC/DC 1 1 6 3 6 3 - -
60 VAV/DC 1 1 - - 6 3 - -
110…120 VAC/DC - - 6 - - - 3.5 3.5
120…127 VAC/DC - - ----3.53.5
110…127 VAC 110…125 VDC 2 2 - - 6 3 - -
220…240 VAC/DC - - ----3.53.5
220…240 VAC 220…250 VDC 2.5 2.5 - 3 6 3 - -
220…250 VAC - - 6 - - - - -
240…250 VAC/DC - -----3.53.5
380…400 VAC ------3.5-
380…440 VAC 3 - - - 6 - - -
415 - 440 VAC ------3.5-
480…525 VAC 4 - - - 6 - - -
480 VAC - - 6 - - - - -
Opening Time (ms) 15 15 18 18 25 25 25 25
(1) Shunt trip permanent supply
ABB 53
AC1615S - 03/10
Acc.
Technical Data
Electrical Operators
Electrical Operator, T1-T3
Rated Voltage AC DC
- 48…60
110...250 110...250
Operating Voltage 85…110% Un
Inrush power absorption during operation 1800 (VA) 1000 (W)
Power on stand by < 100 (mW)
Time opening (s) < 0.1
closing (s) < 0.1
Minimum control impulse time on
opening and closing (ms) >100
This unit is permanently supplied on stand by, a control is applied by means of external
contact in a low power circuit.
Contact characteristics: Voltage AC/DC=24V
Current 50 mA
Electrical Operator, Ts3
Rated Voltage AC DC
-24
- 48…60
120 125
240 250
440 -
Operating Voltage 85…110 % Un
Inrush power absorption 500 (VA) 500 (W)
Service power absorption 350 (VA) 350 (W)
Time constant (ms) 18
Duration opening (s) 0.1
closing (s) 0.1
Minimum duration of the opening and closing
command impulse (ms) 150
Electrical Operator, T4-T5
Voltage AC DC
-24
- 48…60
110…125 110…125
220-250 220-250
380 -
Operating Voltage 85…110%
Inrush power consumption 300VA 300W
In service power consumption 150VA 150W
Duration
opening (s) 1.5
closing (s) < 0.1
resetting (s) 3
Minimum duration of the opening and closing
command impulse (ms) 100
Electrical Operator, T6
Voltage AC DC
-24
- 48…60
110-125 110-125
220-250 220-250
380 -
Operating Voltage 85…110%
Inrush power consumption 400VA 400W
In service power consumption 150VA 150W
Duration
opening (s) 3
closing (s) < 0.1
resetting (s) 5
Minimum duration of the opening and closing
command impulse (ms) 100
54 Discount Schedule DS-STA ABB
AC1615S - 03/10
Acc.
Accessories
Mechanical
T1-T6
Standard Cable Terminal
Frame Wire Size Part Number
(set of 3)
List
Price
Part Number
(set of 4)
List
Price
T1 100A (14 AWG-1/0) Integral Integral
T2 100A (14 AWG-1/0) KT2100-3 KT2100-4
T3 100A (14 AWG - 1/0 kcmil) KT3100-3 KT3100-4
225A (4 AWG - 350 kcmil) KT3225-3 KT3225-4
Ts3 100A (14 AWG - 1/0 kcmil) KTs3100-3
150A (2 AWG - 4/0 kcmil) KTs3150-3
225A (4 AWG - 300 kcmil) KTs3225-3
T4 100A (14 AWG - 1/0 kcmil) KT4100-3 KT4100-4
250A (6 AWG - 350 kcmil) KT4250-3 KT4250-4
T5 300A (250 kcmil - 500 kcmil) KT5300-3 KT5300-4
T5 (1) 400A (2x 3/0 - 2x 250 kcmil) KT5400-3 KT5400-4
T5 600A (2x 3/0 - 2x 500 kcmil) KT5600-3
T6 600A (2x 250 - 2x 500 kcmil) KT6600-3
T6 (1) 800A (3x 2/0 - 3x 400 kcmil) KT6800-3
Terminal Covers for Fixed Breakers - Low Pro le-Kit (kit of 2)
Frame Part Number
(3-Pole)
List
Price
Part Number
(4-Pole)
List
Price
T1 KT1LTC-3 KT1LTC-4
T2 KT2LTC-3 KT2LTC-4
T3 KT3LTC-3 KT3LTC-4
Ts3 KTs3LTC-3 KTs3LTC-4
T4 KT4LTC-3 KT4LTC-4
T5 KT5LTC-3 KT5LTC-4
T6 KT6LTC-3 KT6LTC-4
Terminal Covers for Fixed Breakers - High Pro le-Kit (kit of 2)
Frame Part Number
(3-Pole )
List
Price
Part Number
(4-Pole)
List
Price
T1 KT1HTC-3 KT1HTC-4
T2 KT2HTC-3 KT2HTC-4
T3 KT3HTC-3 KT3HTC-4
Ts3 KTs3HTC-3 KTs3HTC-4
T4 KT4HTC-3 KT4HTC-4
T5 KT5HTC-3 KT5HTC-4
T6 KT6HTC-3 KT6HTC-4
Terminal Cover Fixed Part of CB (Kit of 2)
Frame Part Number
(3-Pole )
List
Price
Part Number
(4-Pole)
List
Price
Ts3 KTs3TCFP-3 KTs3TCFP-4
T4 KT4TCFP-3 KT4TCFP-4
T5 KT5TCFP-3 KT5TCFP-4
KT3100-3
KT1HTC-3
KT4LTC-3
Terminal Cover Seals
Frame Part Number
(3-Pole)
List
Price
T1 - T2 - T3 - T4 - T5 KT5LC-S
(1) Comes standard with high pro le terminal covers.
Note: for power control tap lugs, please consult your local ABB of ce
ABB Discount Schedule DS-STA 55
AC1615S - 03/10
Acc.
Phase Barriers - Low Pro le 100mm - 3.93 in
Frame Part Number
(set of 4)
List
Price
Part Number
(set of 6)
List
Price
T1-T3 KT3PBL-3 KT3PBL-4
T4-T5 KT5PBL-3 KT5PBL-4
T6 KT6PBL-3 KT6PBL-4
Phase barriers - High Pro le 200mm - 7.87 in
Frame Part Number
(set of 4)
List
Price
Part Number
(set of 6)
List
Price
T1-T3 KT3PBH-3 KT3PBH-4
T4-T5 KT5PBH-3 KT5PBH-4
Saddle Terminals for Copper Cables - IEC
Frame Part Number
( set of 3 )
List
Price
Part Number
(set of 4)
List
Price
T2 KT2100S-3 KT2100S-4
T3 KT3225S-3 KT3225S-4
Ts3 K4TES K4TES-4
T4 KT4250S-3 KT4250S-4
T5 KT5300S-3 KT5300S-4
Accessories
Mechanical
T1-T6
KT2EF-3
KT2R-3
KT4EF
(1) Includes high pro le terminal cover.
Extended Front Terminals - IEC
Frame Part Number
(set of 3)
List
Price
Part Number
(set of 4)
List
Price
T2 KT2EF-3 KT2EF-4
T3 KT3EF-3 KT3EF-4
Ts3 KTs3EF-3 KTs3EF-4
T4 KT4EF KT4EF-4
T5 KT5EF KT5EF-4
T6 KT6EF-3 KT6EF-4
Rear Terminals - IEC
Frame Part Number
(set of 3)
List
Price
Part Number
(set of 4)
List
Price
T2 KT2R-3 KT2R-4
T3 KT3R-3 KT3R-4
T4 KT4R-3 KT4R-4
T5 KT5R-3 KT5R-4
T6 KT6R-3 KT6R-4
56 Discount Schedule DS-STA ABB
AC1615S - 03/10
Acc.
Accessories
Mechanical T1-T6
Locking Devices and Handle Operators
OHB65J6
Variable Depth Handle Operators
Frame NEMA Rating Mechanism
Part Number
List
Price Shaft Part Number List
Price
Handle
Part Number
List
Price
T1-T2-T3
1, 3R, 12
KT3VD-M OXP6X430 (16.9”)
OHB65J6
OHY65J6
4, 4X OHB80L6
OHY80L6
1 KT3VD-S (11.8”) KT3VD-H
Ts3
1, 3R, 12
KTs3VD-M OXP10X500 (19.7")
OHB125J10X
4, 4X OHB125L10
1 KTs3VD-S (20") KTs3VD-H
T4-T5
1, 3R, 12
KT5VD-M OXP10X500 (19.7")
OHB125J10X
OHB125L10
4, 4X
1 KT5VD-S (19.7") KT5VD-H
T6
1, 3R, 12
KT6VD-M OXP10X500 (19.7")
OHB125J10X
4, 4X OHB125L10
1 KT5VD-S (19.7") KT6VD-H
Note: Discount schedule DS-H applies for part-numbers starting with OH and OX
Direct Mount Rotary
Frame Breaker
Mounting
Part
Number
List
Price
T1-T2-T3
Fixed, Plug-In
Fixed, Plug-In
Draw-Out
Fixed, Plug-In
Draw-Out
Fixed, Plug-In
Draw-Out
KT3RH
Ts3
KTs3RH
Ts3
KTs3RHW
T4-T5
KT5RH
T4-T5
KT5RHW
T6
KT6RH
T6
KT6RHW
Early Make Contact
Frame Part
Number
List
Price
T2-T3
T4-T5
T6
KT3EM
KT5EM
KT6EM
KT5RH
KT5VD-M, KT5VD-S, KT5VD-H
ABB Discount Schedule DS-STA 57
AC1615S - 03/10
Acc.
Accessories
Mechanical T1-T6
Locking Devices and Handle Operators
KT3LD
Padlock Locking Device
Frame Style Locking Position Breaker
Mounting
Part
Number
List
Price
T1-T2-T3 PLL OPEN/CLOSED Fixed KT3LD
OPEN KT3LDO
Ts3 FLD OPEN Fixed, Plug-In KTs3FLD
Draw-0ut KTs3LDW
T4-T5 FLD OPEN Fixed, Plug-In KT5FLD
Draw-out KT5FLDW
T6 FLD OPEN Fixed, Plug-In KT6FLD
Draw-out KT6FLDW
Keylocks for the Rotary Handle Mechanism
Frame Style Locking Position Keys Part
Number
List
Price
T1-T2-T3 RHL OPEN/CLOSED Different KT3RHL3
Ts3 - OPEN Different KTs3KLFD
Same KTs3KLFD-2
T4-T5
KLF-D OPEN Different KT5KL-D
KLF-S OPEN Same key # 20005 KT5KL-20005
KLF-S OPEN Same key # 20006 KT5KL-20006
KLF-S OPEN Same key # 20007 KT5KL-20007
KLF-S OPEN Same key # 20008 KT5KL-20008
T6
KLF-D OPEN Different KT6KLFD
KLF-S OPEN Same key # 20005 KT6KLFS-20005
KLF-S OPEN Same key # 20006 KT6KLFS-20006
KLF-S OPEN Same key # 20007 KT6KLFS-20007
KLF-S OPEN Same key # 20008 KT6KLFS-20008
Keylocks for the Motor Operator
Frame Style Locking Position Keys Part
Number
List
Price
T4-T5
MOL-D OPEN Different KT5KL-MO-D
MOL-S OPEN Same key # 20005 KT5KL-MO-20005
MOL-S OPEN Same key # 20006 KT5KL-MO-20006
MOL-S OPEN Same key # 20007 KT5KL-MO-20007
MOL-S OPEN Same key # 20008 KT5KL-MO-20008
T6
MOL-D OPEN Different KT6KL-MO-D
MOL-S OPEN Same key # 20005 KT6KL-MO-20005
MOL-S OPEN Same key # 20006 KT6KL-MO-20006
MOL-S OPEN Same key # 20007 KT6KL-MO-20007
MOL-S OPEN Same key # 20008 KT6KL-MO-20008
KT5KL-D
58 Discount Schedule DS-STA ABB
AC1615S - 03/10
Acc.
KT4PMK (on back of
breaker)
KT4PFVR
KT2PFF + KT2PMK (on back of breaker) +
breaker
Accessories
Mechanical T1-T6
Plug-In Kits (1)
Frame Part Number
Adapter Moving Part
List
Price
Part Number
Fixed Part
List
Price
T2 - 3 pole with front terminals KT2PMK KT2PFF
T2 - 4 pole with front terminals KT2PMK-4 KT2PFF-4
T3 - 3 pole with front terminals KT3PMK KT3PFF
T3 - 4 pole with front terminals KT3PMK-4 KT3PFF-4
Ts3 - 3 pole with extended front terminals KTs3PFF
Ts3 - 3 pole with rear terminals KTs3PMK KTs3PFR
Ts3 - 4 pole with extended front terminals KTs3PFF-4
Ts3 - 4 pole with rear terminals KTs3PMK-4 KTs3PFR-4
T4 - 3 pole with extended front terminals KT4PFEF
T4 - 3 pole with rear horizontal terminals KT4PMK KT4PFHR
T4 - 3 pole with rear vertical terminals KT4PFVR
T4 - 3 pole with extended front terminals KT4PFEF-4
T4 - 3 pole with rear horizontal terminals KT4PMK-4 KT4PFHR-4
T4 - 3 pole with rear vertical terminals KT4PFVR-4
T5 400A - 3 pole with extended front terminals KT5PFEF
T5 400A - 3 pole with rear horizontal terminals KT5PMK KT5PFHR
T5 400A - 3 pole with rear vertical terminals KT5PFVR
T5 400A - 4 pole with extended front terminals KT5PFEF-4
T5 400A - 4 pole with rear horizontal terminals KT5PMK-4 KT5PFHR-4
T5 400A - 4 pole with rear vertical terminals KT5PFVR-4
T5 600A - 3 pole with extended front terminals KT5PFEF6
T5 600A - 3 pole with rear horizontal terminals KT5PMK6 KT5PFHR6
T5 600A - 3 pole with rear vertical terminals KT5PFVR6
T5 600A - 4 pole with extended front terminals KT5PFEF6-4
T5 600A - 4 pole with rear horizontal terminals KT5PMK6-4 KT56PFHR6-4
T5 600A - 4 pole with rear vertical terminals KT5PFVR6-4
(1) Plug connectors (T2-T3), adaptors (T4-T5-T6), required when adding accessories to plug-in breakers.
Plug Connectors, T2-T3 (1)
Required when adding accessories to plug-in breakers
Plug Connector Part
Number
List
Price
Shunt trip or UVR KT3PC-3
1 form C plus 1 BA KT3PC-6
3 form C plus 1 BA KT3PC-12
Adaptors, T4-T5-T6 (1)
Required when adding accessories to plug-in or drawout breakers
Adaptors Part
Number
List
Price
1 form C plus 1 BA KT6ADP-6
Shunt trip/UVR KT6ADP-5
Stored energy operator KT6ADP-10
Stored energy operator plus shunt trip/UVR KT6ADP-10
3 form C plus 1BA KT6ADP-12
ABB Discount Schedule DS-STA 59
AC1615S - 03/10
Acc.
KT4WMK (on back of
breaker)
KT5WFVR
Accessories
Mechanical T1-T6
Draw-Out Kits
Item Part Number
Adaptor Moving Part
List
Price
Part Number
Fixed Part
List
Price
TS3 - 3 pole with front terminals KTs3WFF
TS3 - 3 pole with front cable terminals KTs3WMK KTs3WFC
TS3 - 3 pole with rear terminals KTs3WFR
TS3 - 4 pole with front terminals KTs3WFF-4
TS3 - 4 pole with front cable terminals KTs3WMK-4 KTs3WFC-4
TS3 - 4 pole with rear terminals KTs3WFR-4
T4 - 3 pole with extended front terminals KT4WFEF
T4 - 3 pole with rear horizontal terminals KT4WMK KT4WFHR
T4 - 3 pole with rear vertical terminals KT4WFVR
T4 - 4 pole with extended front terminals KT4WFEF-4
T4 - 4 pole with rear horizontal terminals KT4WMK-4 KT4WFHR-4
T4 - 4 pole with rear vertical terminals KT4WFVR-4
T5 - 400A 3 pole with extended front terminals KT5WFEF
T5 - 400A 3 pole with rear horizontal terminals KT5WMK KT5WFHR
T5 - 400A 3 pole with rear vertical terminals KT5WFVR
T5 - 400A 4 pole with front extended terminals KT5WFEF-4
T5 - 400A 4 pole with rear horizontal terminals KT5WMK-4 KT5WFHR-4
T5 - 400A 4 pole with rear vertical terminals KT5WFVR-4
T5 - 600A 3 pole with extended front terminals KT5WFEF6
T5 - 600A 3 pole with rear horizontal terminals KT5WMK6 KT5WFHR6
T5 - 600A 3 pole with rear vertical terminals KT5WFVR6
T5 - 600A 4 pole with extended front terminals KT5WFEF6-4
T5 - 600A 4 pole with rear horizontal terminals KT5WMK6-4 KT5WFHR6-4
T5 - 600A 4 pole with rear vertical terminals KT5WFVR6-4
T6 - 800A 3 pole with extended front terminals KT6WFEF
T6 - 800A 3 pole with rear horizontal terminals KT6WMK KT6WFHR
T6 - 800A 3 pole with rear vertical terminals KT6WFVR
T6 - 800A 4 pole with extended front terminals KT6WFEF-4
T6 - 800A 4 pole with rear horizontal terminals KT6WMK-4 KT6WFHR-4
T6 - 800A 4 pole with rear vertical terminals KT6WFVR-4
Adaptors — T4-T5-T6 (1)
Required when adding accessories to plug-in or drawout breakers
Adaptors Part
Number
List
Price
1 form C plus 1 BA KT6ADP-6
Shunt trip/UVR KT6ADP-5
Stored energy operator KT6ADP-10
Stored energy operator plus shunt trip/UVR KT6ADP-10
3 form C plus 1BA KT6ADP-12
(1) Adaptors (T4-T5-T6), required when adding accessories to draw-out breakers.
60 Discount Schedule DS-STA ABB
AC1615S - 03/10
Acc. Accessories
Mechanical T1-T6
KT3MIF2
KT5FCD
DIN Rail Adapters
Item Part
Number
List
Price
T1/T2 (mounts on 35 mm DIN rail 15mm high) KT2DIN
T3 (mounts on 35mm DIN rail 15mm high) KT3DIN
Ts3 (mounts on 75 mm DIN rail) KTs3DMB
Mechanical Interlocks
T1-T2-T3 Part
Number
List
Price
Sliding bar interlock-front mounted (2 Breakers) KT3MIF2
Sliding bar interlock-front mounted (3 Breakers) KT3MIF3
T3
Rear Interlock-horizontal KT3MI-H
Rear Interlock-vertical KT3MI-V
Ts3
Horizontal KTs3MI-H
Vertical KTs3MI-V
T4-T5 (1)
Interlock frame
Mechanical Interlock frame-horizontal KT5MI-H
Mechanical Interlock frame-vertical KT5MI-V
Plate type
A T4 (F-P-W) T4 (F-P-W) KT5MIP-A
B T4 (F-P-W) T5 400 (F-P-W) OR T5 600 (F) KT5MIP-B
C T4 (F-P-W) T5 600 (P-W) KT5MIP-C
D T5 (F-P-W) T5 400 (F-P-W) OR 630 (F) KT5MIP-D
E T5 (F-P-W) T5 600 (P-W) KT5MIP-E
F T5v (F-P-W) T5 600 (P-W) KT5MIP-F
T6
Horizontal KT6MI-H
Vertical KT6MI-V
Flange
T1-T2-T3 KT3FCD
T4-T5 KT5FCD
T6 KT6FCD
(1) T4-T5 Complete assembly consists of one interlock frame and one plate.
ABB 61
AC1615S - 03/10
Dim.
Approximate Dimensions
T1 & T2
T1 — 3-Pole
T2 — 3 Pole
T1 — Single Pole
90
30 30
181
130
65
76.2
78
83
70
¯ 9 .38
103
17
45 53.25
106.5
XX
Y
Y
>3< 2
62 ABB
AC1615S - 03/10
Dim. Approximate Dimensions
T3
T3 — 3 & 4 Pole
ABB 63
AC1615S - 01/10
Dim.
Approximate Dimensions
Ts3
Ts3 — 3 & 4 Pole
64 ABB
AC1615S - 03/10
Dim. Approximate Dimensions
T4
Flange for
Compartment Door
Drilling Templates of the Compartment Door
Drilling Templates for Support Sheet
For front terminals For rear terminals
3 POLES 4 POLES
Caption
1 Overall dimensions with
cabled accessories mounted
(SOR-C, UVR-C,
RC221-222)
2 Overall dimensions with
cabled auxiliary contacts
mounted
(only 3Q 1SY)
3-4 POLES 3-4 POLES
With flange Without flange
T4 — 3 & 4 Pole
ABB 65
AC1615S - 03/10
Dim.
Approximate Dimensions
T5
Flange for
compartment door
Drilling templates of the compartment door
Drilling templates for support sheet
For front terminals For rear terminals
3 POLES 4 POLES
3 POLES 4 POLES
Fixing on sheet
Caption
1 Overall dimensions with
cabled accessories mounted
(SOR-C, UVR-C,
RC221-222)
2 Overall dimensions with
cabled auxiliary contacts
mounted
(only 3Q 1SY)
With flange (3-4 POLES) Without flange (3-4 POLES)
T5 — 3 & 4 Pole
66 ABB
AC1615S - 03/10
Dim. Approximate Dimensions
T6
T6 — 3 & 4 Pole
ABB 67
AC1615S - 03/10
Dim.
Approximate Dimensions
T7
T7 — 3 & 4 Pole
68 ABB
AC1615S - 03/10
Dim. Approximate Dimensions
T8
ABB 69
AC1615S - 03/10
Dim.
Approximate Dimensions
T8
70 ABB
AC1615S - 03/10
Dim. Approximate Dimensions
T8
ABB 71
AC1615S - 03/10
Dim.
Approximate Dimensions
Variable Depth Mechanism with OHB Handle
T1 - T3
72 ABB
AC1615S - 03/10
Dim.
Approximate Dimensions
Variable Depth Mechanism with OHB Handle
T4 - T5
ABB 73
AC1615S - 03/10
Dim.
Approximate Dimensions
Variable Depth Mechanism
T6
74 ABB
AC1615S - 03/10
Dim.
Approximate Dimensions
Variable Depth Mechanism
T7
ABB 75
AC1615S - 03/10
Notes
76 ABB
AC1615S - 03/10
Notes
Contact us
Canada
ABB Inc.
2117, 32e Avenue
Lachine, QC H8T 3J1
Tel: 514-420-3100
Toll free: 1-800-567-0283
Fax: 514-420-3137
Website: www.abb.ca
Catalogue No. AC1615S (1SDC210001C0203)
New revision
While all care has been taken to ensure that the information
contained in this publication is correct, no responsibility
can be accepted for any inaccuracy. The Company reserves
the right to alter or modify the information contained herein
at any time in the light of technical or other developments.
Technical speci cations are valid under normal operating
conditions only. The Company does not accept any
responsibility for any misuse of the product and cannot be
held liable for indirect or consequential damages.
© Copyright 2012 ABB Inc. All rights reserved.
Contact us
ABB
2117, 32e Avenue
Lachine, QC H8T 3J1
Tel: 514-420-3100
Toll free: 1-800-567-0283
Fax: 514-420-3137
Website: www.abb.ca
Catalogue No. AC1615S (1SDC210001C020)
New revision
(September 2011)
Subject to modification.