Data sheet
OMNIMATE Signal - series RSV
RSV1,6 B4 GR
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Technical data
Creation date December 27, 2018 2:35:34 PM CET
Catalogue status 07.12.2018 / We reserve the right to make technical changes. 2
Dimensions and weights
Net weight 5.24 g
Environmental Product Compliance
REACH SVHC Lead 7439-92-1
System parameters
Product family OMNIMATE Signal - series
RSV
Type of connection
Field connection
Wire connection method Crimp connection Pitch in mm (P) 5 mm
Pitch in inches (P) 0.197 inch Conductor outlet direction 180°
No. of poles 4 L1 in mm 5 mm
L1 in inches 0.197 inch Number of rows 1
Pin series quantity
2
Touch-safe protection acc. to DIN VDE
57 106 Safe from finger touch
Touch-safe protection acc. to DIN VDE
0470 IP 20
Can be coded
Yes
Stripping length 4 mm Plugging force/pole, max. 2 N
Pulling force/pole, max. 2 N
Material data
Insulating material Wemid (PA) Colour Pebble grey
Colour chart (similar) RAL 7032 Insulating material group I
CTI ≥ 600 UL 94 flammability rating V-0
Contact material Copper alloy Storage temperature, min. -25 °C
Storage temperature, max. 55 °C Max. relative humidity during storage 80 %
Operating temperature, max. 100 °C Temperature range, installation, max. 100 °C
Conductors suitable for connection
Clamping range, min. 0.13 mm² Clamping range, max. 3.31 mm²
Flexible, min. H05(07) V-K 0.2 mm² Flexible, max. H05(07) V-K 2.5 mm²
Rated data acc. to IEC
tested acc. to standard
IEC 60664-1, IEC 61984
Rated current, min. no. of poles
(Tu=20°C) 17 A
Rated current, max. no. of poles
(Tu=20°C) 13 A
Rated current, min. no. of poles
(Tu=40°C) 15 A
Rated current, max. no. of poles
(Tu=40°C) 11.5 A
Rated voltage for surge voltage class /
pollution degree II/2 630 V
Rated voltage for surge voltage class /
pollution degree III/2 400 V
Rated voltage for surge voltage class /
pollution degree III/3 250 V
Rated impulse voltage for surge voltage
class/ pollution degree II/2 4 kV
Rated impulse voltage for surge voltage
class/ pollution degree III/2 4 kV
Rated impulse voltage for surge voltage
class/ contamination degree III/3 4 kV
Short-time withstand current resistance
3 x 1s with 120 A