TN-1500 1500W True Sine Wave DC-AC Inverter with Solar Charger series Features : True sine wave output (THD<3%) High surge power up to 3000W U.P.S. mode and energy saving mode (selectable) High efficiency up to 91% Power ON-OFF switch Standby saving mode can be selectable Front panel indicator for operation status Thermostatically controlled cooling fan Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input polarity reverse / Overload / AC circuit breaker Application : Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. Built-in solar / AC charger Computer-based monitoring software (Note.7) 3 years warranty E13 SPECIFICATION MODEL TN-1500-112 RATED POWER (Typ.) TN-1500-124 TN-1500-148 TN-1500-212 TN-1500-224 TN-1500-248 1500W MAXIMUM OUTPUT POWER (Typ.) 1725W for 180 sec. / 1875W for 10 sec. / surge power 3000W for 30 cycles AC VOLTAGE FREQUENCY OUTPUT WAVEFORM Factory setting set at 110VAC Factory setting set at 230VAC 100 / 110 / 115 / 120VAC selectable by setting button S.W 200 / 220 / 230 / 240VAC selectable by setting button S.W 600.1Hz 500.1Hz 50/60Hz selectable by setting button S.W AC REGULATION (Typ.) 3.0% TRANSFER TIME (Typ.) 10ms inverter SAVING MODE (Typ.) Default disabled. Load5W will be changed to standby mode by pass FRONT PANEL INDICATOR Battery voltage level, output load level, saving mode, fault and operation status BAT. VOLTAGE 12V VOLTAGE RANGE (Typ.)Note.3,6 10.5 ~ 15VDC DC CURRENT (Typ.) INPUT 50/60Hz selectable by setting button S.W Note.2 True sine wave (THD<3%) Note.5 150A 24V 48V 12V 24V 48V 21 ~ 30VDC 75A 42 ~ 60VDC 37.5A 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 150A 75A 37.5A 89% 88% 90% 91% 18W @ standby saving mode NO LOAD DISSIPATION OFF MODE CURRENT DRAW 1mA EFFICIENCY (Typ.) 89% Open & sealed Lead Acid Note.2 87% BATTERY TYPES FUSE BATTERY BAT. LOW ALARM INPUT PROTECTION BAT. LOW SHUTDOWN REVERSE POLARITY AC CHARGER 30A*3 22.54% 30A*2 454% 10.54% 214% 424% 10.54% 214% 424% 825 965 685 685 685 Protection type : Shut down o/p voltage, re-power on to recover 105 ~ 115% load for 180 sec., 115% ~ 125% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover 20A STORAGE TEMP., HUMIDITY VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes UL458 (only for "GFCI" receptacle-Type F ) None None Bat I/P - AC I/P:3.0KVAC LVD WITHSTAND VOLTAGE EMC EMISSION OTHERS NOTE None -30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH Bat I/P - AC O/P:3.0KVAC Compliance to FCC class A None EN60950-1 AC O/P - FG:1.5KVAC Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE, E-Mark Compliance to EN61000-4-2,3,4,5,6,8,11 EMC IMMUNITY CHARGE CURRENT (Typ.) 5.5A 2.7A 1.35A 5.5A 2.7A 1.35A CHARGE VOLTAGE 14.3V4% 28.5V4% 57V4% 14.3V4% 28.5V4% 57V4% 45V 75V 25V 45V 75V 28.5V4% 57V4% 14.3V4% 28.5V4% 57V4% MAX OPEN CIRCUIT VOLTAGE 25V SOLAR CHARGER 10A Optional (Only type F) Note.1 0 ~ +40 @ 100% load ; 60 @ 50% load 20% ~ 90% RH non-condensing SAFETY STANDARDS SAFETY & EMC 40A*5 11.34% Protection type : Shut down o/p voltage, re-power on to recover ; by internal RTH3 detect on heatsink of power transistor CIRCUIT BREAKER WORKING HUMIDITY 30A*2 454% 825 OUTPUT SHORT OUTPUT PROTECTION OVER LOAD (Typ.) ENVIRONMENT 30A*3 22.54% By internal fuse open OVER TEMPERATURE GFCI PROCTECTION WORKING TEMP. 40A*5 11.34% CHARGE CURRENT (max.) 30A CHARGE VOLTAGE CONTROL WIRING 14.3V4% DIMENSION PACKING Note.7 RJ11 -RS232 420*220*88mm (L*W*H) 6.85Kg; 2pcs/15.7Kg/1.61CUFT 1.Output derating capacity referenced by curve 1. 2.THD and Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage. 3.Input derating capacity referenced by curve 2. 4.All parameters not specified above are measured at rated load, 25 of ambient temperature and set to factory setting. 5.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage. 6.The tolerance of each voltage value by models is:112/2120.5V;124/2241V;148/2482V. 7.The cable is enclosed for the connection between TN-1500 and computer for software monitoring. File Name:TN-1500-SPEC 2015-05-27 1500W True Sine Wave DC-AC Inverter with Solar Charger TN-1500 series Instructions for TN-1500 monitoring software 1. The monitoring software can be downloaded from product section (with TN-1500 specification) on MEAN WELL's official website, http://www.meanwell.com 2.The monitoring software can run on Windows 7 English version, Windows 7 Chinese (Traditional, Taiwan) version, Windows 8 English version and Windows 8 Chinese (Traditional, Taiwan) version 3. Installation of TN-1500 unit and PC 9 8 7 6 1 6 5 4 3 2 1 Phone Jack RJ11 DB9 FEMALE RJ11 PIN NO. DB9 PIN NO. 2 3 4 3 5 2 Figure 1 4. Explanation of Monitoring Manu 4.1 Main Page Inverter TN V.1.1 Setting Statistics R.C. Power off Pause 2 3 4 1 Exit Solar Charge INVERTER 100 AC Charge 100 0 Battery 5 0 Loading O/P Voltage 110 V O/P Frequency 60.0 Hz Battery Voltage 54.1 V Internal Temperature 10.0 AC In By pass Utility Voltage 0.0 V TN-1500-143 6 Start Date 2007/12/07 03:13:33 PM Reset Date 2007/12/21 01:40:56 PM Power on Remote off Battery low Battery used up Stand by saving mode Abnormal Shutdown Figure 2 1. Setting: Adjustment for output voltage, charging related voltage, frequency, and operation mode. Please refer to Figure 3 for details. 2. Statistics: Calculate for the percentage of operating period for each operation mode. Please refer to Figure 4 for details. 3. R.C. Power off: Power can be turned ON or OFF at the remote location. 4. Pause: Stop refreshing the page of monitoring software. 5. Status of unit: Indicating current operating status of TN-1500. 6. Signals that display current condition of the unit. File Name:TN-1500-SPEC 2015-05-27 1500W True Sine Wave DC-AC Inverter with Solar Charger TN-1500 series 4.2 Setting Page Inverter Setting File Name D:\TN_110RR\20071205\REV\TN_110RR\TNF\TN_1K5_512.TNF Model name TN-1500-212 Manufacture MeanWell Series Number LOC-1234567890 Revision REV:1.10 Date Of Manu. 06/23/2007 I/O Type 212 Voltage 230 V Equalization Volt. 14.3 V 13.5 ~ 15.0V Floating Volt. 13.3 V 13.0 ~ 13.5V Alarm Volt. 11.3 V 11.0 ~ 11.5V Shutdown Volt. 10.5 V 10.0 ~ 11.0V 1 Frequency Stand-by saving mode UPS mode Energy saving mode 50 Hz On On On Comm Ports Off Bauds Rate 9600 1 Read Write Lead 2 3 4 Exit Read OK!! Figure 3 1. User can adjust the settings based on the characteristics of batteries been used: Equalization Voltage, Floating Voltage, Alarm Voltage, and Shut-down Voltage. UPS Mode / Energy Saving Mode selection and AC output voltage and frequency can also be set in this page. 2. Read: Read current settings of the unit. 3. Write: Write the revised setting into the unit. 4. Load: Load in factory default settings. 4.3 Statistic Page Inverter Setting Start Date 2007/12/07 03:13:33 PM 91.2 % Inverter time rate 0.0 % Bypass time rate 8.8 % Shut Down rate 0.0 % Solar time rate 24.7 % Loading average Start Date 2007/12/21 01:40:56 PM 31.9 % Inverter time rate 0.0 % Bypass time rate 68.1 % Shut Down rate 0.0 % Solar time rate 63.7 % Loading average RESET Exit Figure 4 1. Start Date: Date that installing the monitoring software. 2. Reset Date: Date that resetting the statistics. The Start Date will not be influenced by resetting the statistics or turning off the unit. 3 .Inverter time rate: Operating period of "Inverter Mode" represents how many percent of the whole operating period. 4. Bypass time rate: Operating period of "Bypass Mode" (energy provides directly by the utility) represents how many percent of the whole operating period. 5. Shut down rate: Percentage of time period that the unit is under the condition of shut down. * Inverter time rate + Bypass time rate + Shut down rate = 100% 6. Solar time rate: Percentage of time period that the solar charger is functioning after turning on the TN-1500 unit. 7. Loading average: Average loading after turning on the TN-1500 unit. File Name:TN-1500-SPEC 2015-05-27 TN-1500 1500W True Sine Wave DC-AC Inverter with Solar Charger TN 1500 112 A True sine wave inverter +AC charger and solar charger A :TYPE A OUTLET B :TYPE B OUTLET C :TYPE C OUTLET D :TYPE D OUTLET E :TYPE E OUTLET F :TYPE F OUTLET 12:12VDC Bat. Voltage: 24:24VDC 48:48VDC Output: O/P Wattage:1500W series 1:110VAC 2:230VAC AC Output Receptacles (optional) Receptacle type TYPE-A TYPE-B TYPE-C TYPE-D TYPE-E TYPE-F USA EUROPE AUSTRALIA U.K JAPAN GFCI Country E13 Certificate E13 E13 (Expect for 48V input) Derating Curve Mechanical Specification Unit:mm 100 22 44.25 Cat.No.(1GG1HS-212) Wire Range(10-4 AWG Str Cu Soldered Wires) Torque (17.7-26.5 in lb) 88 NEG Chassis Ground POS Reverse Polarity Will Damage The Unit. 60 40 20 Solar Input (30A max) AC INPUT 20 80 LOAD (%) 2xx 11.05 1xx DC INPUT 47 0 - 20 30 40 50 60 70 AMBIENT TEMPERATURE () CURVE 1 48 Air flow direction 12.1 10 + + + 100 LOAD (%) 108.4 80 60 40 20 10 7 10.5VDC 21VDC 42VDC 11.5VDC 23VDC 46VDC 15VDC 30VDC 60VDC (HORIZONTAL) BATTERY INPUT VOLTAGE (V) CURVE 2 AC OUTPUT 203.2 420 ON SOLAR CHARGE AC CHARGE OFF 100 BATTERY Setting LOAD 100 INVERTER On 0 Bat Low er Ci ak es Pr s AC IN BY PASS Saving set r 0 i t Br e cu e to R Remote port Type-A AC OUTPUT ON SOLAR CHARGE AC CHARGE OFF 100 BATTERY Setting LOAD INVERTER 100 On 0 Bat Low er Ci ak r 0 i t Br e cu es Pr s AC IN BY PASS Saving set 27.45 57.75 36.25 15.6 e to R Remote port Type-B 207 220 File Name:TN-1500-SPEC 2015-05-27 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Mean Well: TN-1500-112A TN-1500-124A TN-1500-148A TN-1500-212B TN-1500-224B TN-1500-248B