SPECIFICATION
TS-1000-112□TS-1000-124□TS-1000-148□TS-1000-212□TS-1000-224□TS-1000-248□
50A
21 ~ 30VDC
89%
25A
42 ~ 60VDC
90%
50A
21 ~ 30VDC
91%
25A
42 ~ 60VDC
92%
MODEL
AC VOLTAGE
MAXIMUM OUTPUT POWER (Typ.)
WAVEFORM Note.6
OUTPUT FREQUENCY
AC REGULATION (Typ.)
VOLTAGE RANGE (Typ.)
Note.4,6
EFFICIENCY (Typ.) Note.1
DC CURRENT (Typ.)
INPUT
INPUT
BATTERY
OUTPUT
ENVIRONMENT
FUSE
SAFETY &
EMC
BAT. LOW ALARM
BAT. LOW SHUTDOWN
OVER TEMPERATURE
OUTPUT SHORT
REVERSE POLARITY
GFCI PROCTECTION
PROTECTION
PROTECTION
True sine wave (THD<3%)
100A
10.5 ~ 15VDC
90%
40A*4 40A*2 20A*2
20A*240A*2
±3.0%
10.5 ~ 15VDC
88%
100A
40A*4
90 5℃± ℃
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH3 detect on heatsink of power diode
Protection type : Shut down o/p voltage, re-power on to recover
70 5℃± ℃
By internal fuse open
Optional (Only type F) None
Compliance to FCC class A
None
WORKING TEMP. Note.3
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
SAFETY STANDARDS
0 ~ +40 @ 100% load ; +60 @ 50% load℃℃
20% ~ 90% RH non-condensing
-30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH℃o
U 458 (L only for "GFCI" receptacle-Type F )
None
Compliance to EN61000-4-2,3,8
Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
True sine wave output (THD<3%)
High surge power up to 2000W
High efficiency up to 92%
Power ON-OFF switch
Standby saving mode can be selected
Front panel indicator for operation status
Built-in fan ON-OFF control function
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input reverse polarity / Overload
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
3 years warranty
RATED POWER (Typ.) 1000W
OVER LOAD (Typ.) 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
AC O/P-FG, Bat I/P-FG:100M Ohms/500VDC / 25 / 70% RH℃
VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
■ Features :
OTHERS PACKING
COOLING
4.3Kg; 2pcs/9.6Kg/1.16CUFT
Loading controlled cooling fan for GFCI receptacle-type F ; Thermostatically controlled cooling fan for others.
DIMENSION 345*184*70mm (L*W*H)
NOTE 1.Efficiency is tested by 750W, linear load at 13V, 26V, 52V input voltage.
2.All parameters not specified above are measured at rated load, 25 of ambient temperature and set to factory setting.
℃
3.Output derating capacity referenced by curve 1.
4.Input derating capacity referenced by curve 2.
5.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248 2V
→± →± →±
6.THD is tested by 1000W, linear load at 13,26,52V input voltage.
1150W for 180 sec. / 1500W for 10 sec. / surge power 2000W for 30 cycles
11.3 4%±22.5 4%±45 4%±45 4%±22.5 4%±
10.5 4%±21 4%±42 4%±42 4%±21 4%±
11.3 4%±
10.5 4%±
1000W True Sine Wave DC-AC Power Inverter TS-1000 series
File Name:TS-1000-SPEC 2015-05-27
50 0.1Hz 50/60Hz selectable by setting button S.W±
60 0.1Hz 50/60Hz selectable by setting button S.W±
FRONT PANEL INDICATOR
SAVING MODE (Typ.) Default disabled. Load 5W will be changed to standby mode≦
Battery voltage level, output load level, saving mode, fault and operation status
24V 48V 24V 48V
BAT. VOLTAGE 12V12V
NO LOAD DISSIPATION ≦6W @ standby saving mode
OFF MODE CURRENT DRAW ≦1mA
BATTERY TYPES Open & sealed lead acid
200 / 220 / 230 / 240VAC selectable by setting button S.W
100 / 110 / 115 / 120VAC selectable by setting button S.W
Factory setting set at 110VAC Factory setting set at 230VAC
LVD None EN60950-1
E
13
MTBF 66.9K hrs min. MIL-HDBK-217F (25 )℃
EMC IMMUNITY
EMC EMISSION