IDEC LD6A LED Signalight Towers
Think Automation and beyond...
New
Focused
brightness and
visibility
2
Stylish design
Lens shape offers visibility in all directions
Five different mounting styles
Alarm can easily be heard in noisy areas
Custom arrangement of LED units
LD6A Signalight Towers
Ergonomically designed for instant visual & audible recognition
LD6A SignaLights combine the latest LED technology with IDEC safety technology. With a new concept and
innovative design, LD6A light towers are ideal for factory automation and many applications.
IEC Standards Color Arrangement
Indicating towers mounted on machines should have colors in the following order from the top down; RED, YELLOW,
BLUE, GREEN, WHITE to meet IEC Standards. (IEC60204-1 Fifth edition Chapter 10.3.2 Colors)
Indicator Light Color Significance (with respect to machine condition)
Color Indication Explanation Operator Action
RED Emergency Hazardous condition Immediate action to deal with
hazardous condition
YELLOW Abnormal Abnormal condition
Impending critical condition
Monitoring and/or intervention
(for example by re-establishing
the intended function)
BLUE Mandatory Indication of a condition that requires action by the operator Mandatory action
GREEN Normal Normal condition Optional
WHITE Neutral Other conditions; may be used whenever doubt exists about
the application of RED, YELLOW, GREEN, BLUE Monitoring
3
Pole Mount
(w/Base)
Wall
Mount
Frame
Mount
Direct
Mount
Pole Mount
(w/L-shaped bracket)
5 Different Types to Choose From
Wall Mount
Pole Mount
(w/L-shaped bracket)
Direct Mount
Visible
Frame Mount
60mm
40mm
Audible
Pole Mount
(w/Base)
4
Black and light gray housing available.
L-shaped bracket available for pole
mounting. Can also be mounted directly
to equipment.
The unique, secure terminal-style of
the LED module makes assembly quick
and easy.
Highly reliable plug-in terminals allow
for easy expansion of the LED module.
Steady frame mount, wall mount, direct
mount, pole mount with base IP65
Steady pole mount with L-shaped bracket IP23
Flashing/Alarm frame mount, wall mount, direct
mount, pole mount with base IP54
Flashing/Alarm pole mount with L-shaped bracket IP23
Oval shape with striped design provides focused visibility and brightness
Different mounting styles
IP65 protection Two housing colors
With LD6A, there is a clear
distinction between illuminated
and non-illuminated areas.
RED ?
Because there is no distinction
between the illuminated areas,
it can be confusing to determine
which lens is actually illuminated.
Conventional modelsIDEC LD6A
The non-illuminated area
between the lenses makes the
illuminated color more visible,
even at a distance.
Easy Assembly Plug-in Terminals
L-shaped
bracket
Black
Light Gray
Plug-in terminal
Pole mount without
bracket or base
Easy installation and assembly
Unique design improves brightness and visibility
5
Light ON Light OFF
IEC60073 Sixth edition 2002 Chapter 4.2.3
“Coding by changing of characteristics over time”
Flashing cycle complies with IEC standards: 1.75Hz (approx. 105 times per minute)
Three different illumination methods and a unique lens shape provide high visibility from all directions.
1
1
2
3
2
3
2
1
3
Condensing lens
(spo llumination)
By combining a diffusing lens, which
diffuses light in a wide arc, with a
condensing lens, a super-bright area
is created providing high visibility. In
addition, illumination through a light
guide enhances visibility when the
SignaLight is viewed from below.
Diffusing lens
Diffusing lens
Light Guide
Longitudinal sectional viewCross sectional view Light Guide
Condensing lens
Condensing lens (spot illumination)
Condensing
lens (spot
illumination)
Condensing lens
(spot illumination)
Illumination through light guide
Illumination through
light guide
Illumination through
diffusing lens
Illumination through
diffusing lens
Illumination through diffusing lens
LED LED
Lens and Light Characteristics
Light ON
Light OFF
Clear lens type available
Because a reflective mirror is not installed in the the LED unit,
diffuse reflection does not occur because of external or bright light.
Also, when the clear lens type is used, it is very obvious when the
light is on or off, even in a bright environment.
Alarm is 3.3kHz with a maximum sound level of 90dB. With a unique IDEC
resonant design, the SignaLight has a frequency that is audible to the human
ear and provides clear sound in 360 degrees. As a result, sound recognition
improves as the alarm can be heard in a noisy environment, enhancing safety.
Unique design with 360-degree sound. Two alarm styles available.
30°
Competitor B (ø60)Competitor A (ø60)
Measured at: IDEC facility Measured distance: 1m
IDEC
30°
Sound
Front (0º)
60° 60°
90dB
90° 90°
120° 120°
150°
180°
150°
Comparison of alarm volume from 1m distance
(volume: maximum)
The alarm can be heard from all directions as the sound
spreads out evenly.
Alarm volume adjustment
(adjustable within a range of 70 to 90 dB)
Alarm 1: Intermittent short sound
Alarm 2: Intermittent long sound
Steady/flashing/alarm model shown.
Light gray or black housing available.
Lens shape offers visibility from all directions
Flashing and Alarm models provide added safety
Clear On/Off visibility
6
LD6A LED SignaLight Towers
Unique Striped Design Improves Visibility
General Specifications
Safety Standards IEC60947-5-1, EN60947-5-1, UL508,
CSA C22.2 No.14
Operating Temperature –25 to +55ºC (no freezing)
Operating Humidity 45 to 85% RH (no condensation)
Storage Temperature –40 to +75ºC (no freezing)
Overvoltage Category III (IEC60664-1)
Impulse Withstand Voltage 800V (IEC60947-1)
Insulation Resistance 100 MΩ minimum (500V DC megger)
Dielectric Strength Between live and dead parts: 1000V AC, 1 minute
Pollution Degree 3
Corrosion Immunity Atmosphere free from corrosive gases
Vibration Resistance Operating extremes: 10 to 55Hz, amplitude 0.5 mm
Shock Resistance Operating extremes: 147 m/s2, 6 shocks each in 6 axes
Degree of Protection
(IEC60529)
Steady frame mount, wall mount, direct
mount, pole mount with base IP65
Steady pole mount with L-shaped bracket IP23
Flashing/Alarm frame mount, wall mount, direct
mount, pole mount with base IP54
Flashing/Alarm pole mount with L-shaped bracket IP23
Housing Color Black, Light gray
Material
Housing: ABS resin
Lens: AS resin
Pole: Steel (nickel-chrome plated)
Pole base: Diecast aluminum
Wire 22AWG (UL1007)
Functional Specifications
Rated Insulation Voltage 60V
Operating Voltage 24V AC/DC ±10%
Rated Voltage (Ue) 24V AC/DC
LED Color Code R (red), Y (yellow), S (blue),
G (green), W (pure white)
LED
Illumination Color R, Y S, G W
Rated Current (per tier) 25mA 30mA 20mA
Power Consumption (per tier) 0.6W 0.75W 0.5W
LED Life (Note)
Approx. 30,000 hours (until brightness is reduced
to 50% of the initial value in a 25ºC operating
environment)
Flashing Cycle (IEC60073) Approx. 105 flashes per minute (1.75 Hz)
Alarm
Alarm Cycle Alarm 1: approx. 700 times per minute
Alarm 2: approx. 35 times per minute
Current Draw 110mA max.
Inrush Current AC: 400mA max. DC: 250mA max.
Alarm Volume 70 to 90dB, at 1m (volume adjustable)
Acoustic Frequency Approx. 3.3kHz
Note: Life of the LED varies according to operating conditions and environment.
External Contact Ratings
LED
AC Contact Capacity
(per tier)
Current Capacity 100mA min.
Dielectric Strength 35V AC min.
DC Contact Capacity,
Transistor Capacity (per tier)
Current Capacity 100mA min.
Dielectric Strength 35V min.
Leakage Current 0.1mA max.
Alarm
AC Contact Capacity
(per alarm)
Current Capacity 400mA min.
Dielectric Strength 35V AC min.
DC Contact Capacity,
Transistor Capacity
(per alarm)
Current Capacity 300mA min.
Dielectric Strength 35V min.
Leakage Current 0.1mA max.
The striped design with non-illuminated area between the lenses makes the
illuminated color very visible.
Unique oval lens shape provides high-visibility from different directions.
Five different mounting styles available: frame mount, wall mount, direct mount
and pole mount (round or L-shaped bracket).
Clear lens models available to clearly distinguish between illuminated and
non-illuminated lenses.
Custom configuration is possible.
Flashing cycle: 1.75Hz (approx. 105 flashes per minute) conforms to international
standard IEC 60073.
Alarm (3.3kHz, 2 different styles) can be heard in 360º degrees. Adjustable volume
(70 to 90dB).
Degree of protection: IP65 Steady units and IP54 Flashing units (using frame, wall,
direct and pole mount with round base), IP23 Steady and Flashing units using pole
mount with L-shaped bracket.
(w/L-shaped bracket)
Frame mount
Direct mount Pole mount
(w/Base)
Wall mount
www.IDEC.com/usa/LD6A
800-262-IDEC
7
Part Number Structure
LD6A - 5 W Z Q B - RYSGW C
Function
blank: steady
Z: steady/flashing/alarm
(Note)
Note: Specify illumination color from the top tier.
Number of tiers
1: 1 tier
2: 2 tiers
3: 3 tiers
4: 4 tiers
5: 5 tiers
Mounting style
G: frame mount
W: wall mount
D: direct mount
P: pole mount w/ base
K: pole mount w/L-shaped bracket
Housing color
B: black
W: light gray
Voltage
Q: 24V AC/DC
Lens color
blank: same as LED color
(standard type)
C: transparent
(clear lens type)
LED color code
(specify code from top tier)
R: red
Y: yellow
S: blue
G: green
W: pure white
Assembled Products
Mounting
Style Tiers LED Color
Code
Steady Steady/Flashing/Alarm
Part Number Weight
(approx.) Part Number Weight
(approx.)
G: Frame
Mount
1 R, Y, S, G, W LD6A-1GQ*- 220g LD6A-1GZQ*- 310g
2 RY, RG LD6A-2GQ*- 260g LD6A-2GZQ*- 350g
3 RYS, RYG LD6A-3GQ*- 300g LD6A-3GZQ*- 390g
4 RYSG LD6A-4GQ*- 340g LD6A-4GZQ*- 430g
5 RYSGW LD6A-5GQ*- 380g LD6A-5GZQ*- 470g
W: Wall
Mount
1 R, Y, S, G, W LD6A-1WQ*- 225g LD6A-1WZQ*- 315g
2 RY, RG LD6A-2WQ*- 265g LD6A-2WZQ*- 355g
3 RYS, RYG LD6A-3WQ*- 305g LD6A-3WZQ*- 395g
4 RYSG LD6A-4WQ*- 345g LD6A-4WZQ*- 435g
5 RYSGW LD6A-5WQ*- 385g LD6A-5WZQ*- 475g
D: Direct
Mount
1 R, Y, S, G, W LD6A-1DQ*- 185g LD6A-1DZQ*- 275g
2 RY, RG LD6A-2DQ*- 225g LD6A-2DZQ*- 315g
3 RYS, RYG LD6A-3DQ*- 265g LD6A-3DZQ*- 355g
4 RYSG LD6A-4DQ*- 305g LD6A-4DZQ*- 395g
5 RYSGW LD6A-5DQ*- 345g LD6A-5DZQ*- 435g
P: Pole Mount
(with base)
1 R, Y, S, G, W LD6A-1PQ*- 645g LD6A-1PZQ*- 735g
2 RY, RG LD6A-2PQ*- 685g LD6A-2PZQ*- 775g
3 RYS, RYG LD6A-3PQ*- 725g LD6A-3PZQ*- 815g
4 RYSG LD6A-4PQ*- 765g LD6A-4PZQ*- 855g
5 RYSGW LD6A-5PQ*- 805g LD6A-5PZQ*- 895g
K: Pole Mount
(with L-shaped
bracket)
1 R, Y, S, G, W LD6A-1KQ*- 640g LD6A-1KZQ*- 730g
2 RY, RG LD6A-2KQ*- 680g LD6A-2KZQ*- 770g
3 RYS, RYG LD6A-3KQ*- 720g LD6A-3KZQ*- 810g
4 RYSG LD6A-4KQ*- 760g LD6A-4KZQ*- 850g
5 RYSGW LD6A-5KQ*- 800g LD6A-5KZQ*- 890g
Specify housing color code in place of *: B (black), W (light gray)•
Specify illumination color in place of • starting with the top tier. State the LED color code from the left.
R (red), Y (yellow), S (blue), G (green), W (pure white)
Example: When the LED color is • RYGSW => LD6A-5GQW-RYGSW
Clear lens type also available. Specify “C” after the LED color code. •
Example: LD6A-5GQW-RYSGW => LD6A-5GQW-RYSGWC
Combination of LED Color and Lens Color
LED Color Color Lens Type Clear Lens Type
R: Red Red lens Clear lens
Y: Yellow Yellow lens Clear lens
S: Blue Blue lens Clear lens
G: Green Green lens Clear lens
W: Pure white Clear lens
For pure white (W) LED, a clear lens is used in both color and
clear lens configurations.
Mounting Parts Included
Mounting Style Supplied Parts
G: Frame mount
M4 screw (4 pcs)*, M4 spring washer (4 pcs)*, M4 plain washer (4
pcs)*, M5 screw (2 pcs),
M5 spring washer (2 pcs), M5 plain washer (2 pcs), bracket (1 pc)
W: Wall mount
M4 screw (20 mm) (4 pcs), M4 screw (8 mm) (4 pcs)*, M4 spring washer
(8 pcs)* M4 plain washer (8 pcs)*,
M4 nut (4 pcs), bracket (1 pc), gasket (1 pc)
D: Direct mount
M5 screw (4 pcs)*, M5 spring washer (4 pcs)*, M5 plain washer (4
pcs)*, M5 nut (4 pcs)*, O-ring (4 pcs),
gasket (1 pc)
P: Pole mount (with base) M5 screw (4 pcs), M5 spring washer (4 pcs), M5 plain washer (4 pcs),
M5 nut (4 pcs), O-ring (4 pcs), gasket (1 pc)
K: Pole mount (with
L-shaped bracket) M22 plain washer 2 (pcs), M22 nut (2 pcs), bracket (1 pc)
*For black housing, black screws and washers are supplied. For light gray housing, silver screws
and washers are supplied.
8
Sub-component Parts
Base Module
Item Mounting Style Part Number Notes
Steady Steady/Flashing/Alarm
Frame Mount LD6A-0GQ* LD6A-0GZQ*
A top cap is
supplied.
Wall Mount LD6A-0WQ* LD6A-0WZQ*
Direct Mount LD6A-0DQ* LD6A-0DZQ*
Pole Mount (with base) LD6A-0PQ* LD6A-0PZQ*
Pole Mount (with L-shaped bracket) LD6A-0KQ* LD6A-0KZQ*
Specify a housing color code in place of *: B (black), W (light gray)•
Do not supply power to the base module without connecting LED modules.•
LED Module
Item Lens Part Number LED Color Code
Black
Color lens LD9Z-6ALB- R, Y, S, G, W
Clear lens LD9Z-6ALB- C R, Y, S, G
Light gray
Color lens LD9Z-6ALW- R, Y, S, G, W
Clear lens LD9Z-6ALW- C R, Y, S, G
Specify an LED color code in place of • : R (red), Y (yellow), S (blue), G (green), W (pure white)
When using pure white (W) with a clear lens, order LD9Z-6ALB-W (black housing) or LD9Z-6ALW-W (light gray housing).•
Center Screw Set
Item Part Number Notes
1 tier LD9Z-6AC1
A plain washer and spring washer are supplied.
2 tiers LD9Z-6AC2
3 tiers LD9Z-6AC3
4 tiers LD9Z-6AC4
5 tiers LD9Z-6AC5
Replacement Parts
Item Description Part Number Notes
Top Cap Black LD9Z-6ATB
A top cap is supplied with a base module.
Light gray LD9Z-6ATW
L-shaped Bracket Metal
(chrome-plated) LD9Z-6AK Two plain washers and two nuts are supplied.
Ordering Examples
[Ex. 1] When ordering LD6A-3PQW-RYG as sub-component parts, specify the following:
Pole mount (with base), steady, light gray housing, 3 tiers, color lens LED modules with Red, Yellow, and Green LED
Base module (pole mount with base, steady, light gray housing) LD6A-0PQW 1 piece
LED module (red LED with color lens, light gray housing) LD9Z-6ALW-R 1 piece
LED module (yellow LED with color lens, light gray housing) LD9Z-6ALW-Y 1 piece
LED module (green LED with color lens, light gray housing) LD9Z-6ALW-G 1 piece
Center screw set (3 tiers) LD9Z-6AC3 1 piece
[Ex. 2] When ordering LD6A-5WZQB-RYSGWC as sub-component parts, specify the following:
Wall mount, steady/flashing/alarm, black housing, 5 tiers, clear lens LED modules with Red, Yellow, Blue, Green, and Pure white LED
Base module (wall mount, steady/flashing/alarm, black housing) LD6A-0WZQB 1 piece
LED module (red LED with clear lens, black housing) LD9Z-6ALB-RC 1 piece
LED module (yellow LED with clear lens, black housing) LD9Z-6ALB-YC 1 piece
LED module (blue LED with clear lens, black housing) LD9Z-6ALB-SC 1 piece
LED module (green LED with clear lens, black housing) LD9Z-6ALB-GC 1 piece
LED module (pure white LED with clear lens, black housing) LD9Z-6ALB-W 1 piece
Center screw set (5 tiers) LD9Z-6AC5 1 piece
9
Wiring Example (Steady Light)
Fuse
1A Power supply
24V AC/DC Power supply
24V DC
Power supply
24V DC
Power supply line:
Yellow
Power supply line:
Yellow
Power supply line:
Yellow
Red
Yellow
Green
Blue
Pure White
Red
Yellow
Green
Blue
Pure White
Red
Yellow
Green
Blue
Pure White
LED Red: Red
LED Yellow: Orange
LED Blue: Blue
LED Green: Green
LED
Pure White
: White
LED Red: Red
LED Yellow: Orange
LED Blue: Blue
LED Green: Green
LED
Pure White
: White
LED Red: Red
LED Yellow: Orange
LED Blue: Blue
LED Green: Green
LED
Pure White
: White
External contact
for steady light
(–)
(–)
(+)
(+)
Fuse
1A
External transistor
for steady light
External transistor
for steady light
Fuse
1A
Mechanical Contacts NPN Transistors PNP Transistors
*Complies with IEC60947-5-1.
Panel Cut-Out
ø22
2-ø11
35
Frame Mount Wall Mount
44.0
2-M5
4-ø4.5
46
23
16
Wire Entry
ø15
+1
0
ø54
4-ø5.5
90°
Direct Mount
Wire Entry
ø15
Front
4-ø5.5
ø73
4-ø4.5
ø73
90°
Pole Mount (with base)
Pattern APattern BPattern C Pattern D
120°
120°
ø40
3-ø4.5
4-ø5.5
ø54
Wire
Entry
ø15
Wire
Entry
ø15
Wire
Entry
ø15
Wire Entry
ø15
Front FrontFront
Front
w/ L-shaped
bracket
w/o L-shaped
bracket
Pole Mount
(with L-shaped bracket)
Dimension Table
Tiers Frame Mount
(L1)
Wall Mount
(L2)
Direct Mount
(L3)
Pole Mount
w/ base (L4) w/ L-shaped bracket (L5)
1 156 156 98 408 372
2 186 186 128 438 402
3 216 216 158 468 432
4 246 246 188 498 462
5 276 276 218 528 492
Dimensions (Steady Light)
Direct Mount
Frame Mount Wall Mount Pole Mount (with base) Pole Mount (with L-shaped bracket)
All dimensions in mm.
40
60
52.4
40
40
60
53.4
40
60
40
ø70
60
40
ø94
60
40
2517.4
12.6
2517.4
12.6
2517.4
12.6
2517.4
12.6
2517.4
12.6
L1980
L2
L31040
L4730
L580
730 32
65
65
980
60
80
40
Conduit Port
M20×P1.5
Front Front Front
10
Panel Cut-Out
*Complies with IEC60947-5-1.
ø22
2-ø11
35
Frame Mount Wall Mount
44.0
2-M5
4-ø4.5
46
23
16
Wire Entry
ø15
+1
0
ø54
4-ø5.5
90°
Direct Mount
Wire Entry
ø15
Front
4-ø5.5
ø73
4-ø4.5
ø73
90°
Pole Mount (with base)
Pattern APattern BPattern C Pattern D
120°
120°
ø40
3-ø4.5
4-ø5.5
ø54
Wire
Entry
ø15
Wire
Entry
ø15
Wire
Entry
ø15
Wire Entry
ø15
Front FrontFront
Front
w/ L-shaped
bracket
w/o L-shaped
bracket
Pole Mount
(with L-shaped bracket)
Mechanical Contacts NPN Transistors PNP Transistors
Flashing COM Brown
Power Gray
Power: Yellow Fuse 1A Power supply
24V AC/DC
Red
Yellow
Green
Blue
Pure White
LED Red: Red
LED Yellow: Orange
LED Blue: Blue
LED Green: Green
LED
Pure White
: White
Alarm 1: Purple
Alarm 2: Light Blue
External contact
for steady light/alarm
External contact
for flashing light
(–)
(+)
LED Red: Red
LED Yellow: Orange
LED Blue: Blue
LED Green: Green
LED
Pure White
: White
Alarm1: Purple
Alarm 2 Light Blue
Red
Yellow
Green
Blue
Pure White
External contact
for steady light/alarm
External contact
for flashing light
Flashing COM Brown
Power Gray
Power: Yellow Fuse 1A Power supply
24V DC
Wiring Example (Flashing Light and Alarm)
2517.4
12.6
2517.4
12.6
2517.4
12.6
2517.4
12.6
2517.4
12.6
52.4
40
60
40
40
60
40
53.4
60
40
40
60
60
40
ø94
L1900
65
L2
65
L3960
650 L4
L580
32650
900
ø70
60
80
40
Conduit Port
M20×P1.5
FrontFront Front
Dimensions (Steady/Flashing/Alarm)
Direct Mount
Frame Mount Wall Mount Pole Mount (with base) Pole Mount (with L-shaped bracket)
All dimensions in mm.
Dimension Table
Tiers Frame Mount
(L1)
Wall Mount
(L2)
Direct Mount
(L3)
Pole Mount
w/ base (L4) w/ L-shaped bracket (L5)
1 228 228 170 480 444
2 258 258 200 510 474
3 288 288 230 540 504
4 318 318 260 570 534
5 348 348 290 600 564
11
Safety Precautions
Turn off the power to the LD6A before mounting, removing, wiring or
assembling the LED module. Make sure the wiring is done correctly otherwise
electrical shock or fire may result.
Mount the LD6A on a solid surface not subject to vibrations.
Do not mount the LD6A upside-down or horizontally.
Do not leave the LD6A without a cap or unassembled.
Install the supplied gasket, otherwise the waterproof seal will be compromised.
Do not apply any chemicals that may corrode the plastic materials.
If the LD6A is subjected to strong vibrations, the hexagon socket screw may
become loose. Take measures to prevent loosening. (See the figure below.)
2-M4 holes for hexagon socket
set screws
recommended tightening torque:
1.1 to1.2 Nm
Do not loosen any screws if the tightening torque is not specified.
Instructions
Mounting
See drawing below regarding the mounting of the LD6A.
For panel cut-out dimensions, see pages 9 and 10.
Postion the LD6A to make sure the alarm sound is the loudest. (Steady/
flashing/alarm type)
Frame Mounting
Insert two nuts in the frame, and attach the bracket using two M5 screws. 1.
Recommended tightening torque: 2.6 to 2.7 N·m
Mount the LD6A to the bracket using four M4 screws. 2.
Recommended tightening torque: 1.6 to 1.7 N·m
Frame (Note)
Frame Nut (Note)
Bracket
Plain Washer
Spring Washer
M5 Screw
M4 Screw, Spring Washer, Plain Washer
Note: See table below for typical examples of frames and nuts. Consult the
manufacturer of the frame for the installation method of the frame nut.
Examples of recommended frames and frame nuts
Frame Size Frame Frame Nut Manufacturer
30 mm* SFF-302
SFB-001
SFB-4B5
SFB-101 SUS
Corporation
(Japan)
40 mm SFF-402
SFB-008
SFB-4A5
SFB-108
*The mounting bracket for the housing is 40 mm.
When using a frame mount type, be sure to
use flexible conduit, otherwise the waterproof
seal will be compromised.
Refer to the “Example of Flexible Conduit”
shown on the right.
Example of Flexible Conduit
Conduit Port Size M20
Gland AL16/M20/A/BL
Conduit PAFS16BL
Manufacturer Adaptaflex
Wall Mounting
Make four tapped holes in the mounting panel and mount the bracket 1.
and gasket using four screws (M4 x 20).
Recommended tightening torque: 1.6 to 1.7 N·m
Gland
Conduit
Conduit port
(M20×P1.5)
Mount the LD6A to the bracket using four screws (M4 x 8). 2.
Recommended tightening torque: 1.6 to 1.7 N·m
Direct Mounting
Recommended tightening torque:
2.6 to 2.7 N·m
Pole Mounting (with base)
The pole mount type can be installed in four ways. The recommended mounting
method (pattern A from page 9 or 10) is described below.
Recommended tightening torque: 2.6 to 2.7 N·m (M5 screw)
Pole Mounting (with L-shaped bracket)
Using L-shaped bracket1.
Recommended tightening torque: 10 to 11 N·m (M10)
Recommended tightening torque: 25 to 26 N·m (M22)
Not using L-shaped bracket2.
Remove the bushing, hexagonal nut (M22), plain washer, and L-shaped
bracket from the LD6A and install in the following order: plain washer,
hexagonal nut (M22), and bushing.
Recommended tightening torque: 25 to 26 N·m (M22)
1. Using L-shaped bracket 2. Not using L-shaped bracket
The parts marked with * are not supplied and should be provided by the user.
Panel
Nut
Gasket
Bracket
Plain Washer
Spring Washer
M4 Screw (20 mm)
M4 Screw (8 mm), Spring Washer, Plain Washer
Panel
M5 Screw
Spring Washer
Plain Washer
O-ring
Base
Gasket
Nut
Pole Stand
4-M5 Mounting Hole
(recommended)
3-M4 Mounting Hole
4-M4 Mounting Hole
4-M5
Mounting
Hole
M5 Screw
O-ring
Pole Stand
Gasket
Panel
Plain Washer
Spring Washer
Nut
Hexagonal
nut
(M22)
Hexagonal
bolt
(M10)
Hexagonal
nut
(M10)
Spring washer
Plain washer
Plain washer
Bushing
Hexagonal nut
(M22)
USA
IDEC Corporation
Tel: (408) 747-0550
opencontact@IDEC.com
Canada
IDEC Canada Ltd.
Tel: (905) 890-8561
sales@ca.IDEC.com
Australia
IDEC Australia Pty. Ltd.
Tel: +61-3-9763-3244
sales@au.IDEC.com
Japan
IDEC Corporation
Tel: +81-6-6398-2571
products@IDEC.co.jp
United Kingdom
IDEC Electronics Ltd.
Tel: +44-1256-321000
IDEC@uk.IDEC.com
Germany
IDEC Elektrotechnik GmbH
Tel: +49-40-253054-0
service@IDEC.de
Hong Kong
IDEC (H.K.) Co., Ltd.
Tel: +852-2803-8989
info@hk.IDEC.com
China/Beijing
IDEC (Beijing) Corporation
Tel: +86-10-6581-6131
idec@cn.IDEC.com
China/Shanghai
IDEC (Shanghai) Corporation
Tel: +86-21-5353-1000
idec@cn.IDEC.com
China/Shenzhen
IDEC (Shenzhen) Corporation
Tel: +86-755-8356-2977
Singapore
IDEC Asia Pte. Ltd.
Tel: +65-6746-1155
info@sg.IDEC.com
Taiwan
IDEC Taiwan Corporation
Tel: +886-2-2698-3929
service@tw.IDEC.com
©2010 IDEC Corporation. All Rights Reserved.
Catalog No. LD9Y-B100-0 4/10 10K
www.IDEC.com
Specifications and other descriptions in this catalog are subject to change without notice.
Replacement and Addition of LED Modules
Make sure to turn power off.
Insert a flat screwdriver into the cap recess as shown below, lift up the cap, and
remove with your hands. Use a flat screwdriver with maximum 1-mm thick and
7-mm wide tip.
Remove the center screw before reassembling the LED modules.
When assembling the LED modules, make sure to align the recess of the cap with
the recess of the LED module. Otherwise, damage may result.
Recommended tightening torque: 0.4 to 0.5 N·m.
Recess
Recess
Recess
Recess
LED module
Top Cap
Gasket
Insert flat screwdriver into recess
1
23
Note the correct orientation when assembling the LED modules.
Tighten the screws to the recommended tightening torque. The LED module may be
damaged if the screw is loose during operation.
Do not touch the metal plug on the LED module. Otherwise, LED elements maybe
damaged due to static electricity.
Use a maximum of 5 tiers.
Select the correct screw length depending on the number of tiers.
Do not remove the gasket from the LED module. Otherwise, the waterproof seal
will be compromised.
Wiring
For wiring, see the wiring diagrams on pages 9 and 10.
Incorrect wiring may damage the internal circuit.
Be sure to insulate unused wires.
Connect a 1A fuse to the power line as shown in the Wiring Examples on pages 9
and 10.
Use a UL listed external fuse holder.
Use a class 2 power supply only.
When using LED modules of the same color for two or more tiers, determine
contact capacity in referencet to the LED current, because only one wire is used to
light all tiers of the same color.
Do not apply voltage to flashing (brown) lines.
Do not connect flashing (brown) line to the power lines. The internal circuit may be
damaged.
Do not turn on steady and flashing circuits simultaneously.
Do not turn on alarms 1 and 2 simultaneously.
Wire Color
Wire Color Steady Steady, Flashing, Alarm
Red LED Module – Red LED Module – Red
Orange LED Module – Yellow LED Module – Yellow
Blue LED Module – Blue LED Module – Blue
Green LED Module – Green LED Module – Green
White LED Module – Pure White LED Module – Pure White
Purple Alarm 1
Light Blue Alarm 2
Brown Flashing COM
Gray Power Line
Yellow Power Line Power Line
For information on external contacts, see “External Contact Ratings” on page 6.
Alarm Volume Adjustment
Move the volume adjustment to the right or left to change the volume.
When the adjustment lever is all the way to the right the volume is at its maximum.
The adjustment lever may be damaged if forced.
Max.
Min.
Alarm volume
adjustment lever
High Temperature Limitations
The external temperature cannot exceed 50ºC when all tiers are lit at the same time
in the following combinations:
Three tiers 1.
Two or more tiers of blue and green (example: Red-Green-Blue,
Green-Green-Red)
Four or five tiers (example: Red-Yellow-Green-Pure White, Red-Yellow-Blue-2.
Green-Pure White)
www.IDEC.com/usa/LD6A