SPLFA-2
SPLFA30F
AC-DC Power Supplies Open Frame/Enclosed Value-added Type
SPLF A 30 F -O -O
Ordering information
1 2 3 4 5 6
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional
C
: with Coating
MODEL SPLFA30F-5 SPLFA30F-12 SPLFA30F-24
MAX OUTPUT WATTAGE[W] 30.0 30.0 31.2
DC OUTPUT 5V 6A 12V 2.5A 24V 1.3A
SPECIFICATIONS
MODEL SPLFA30F-5 SPLFA30F-12 SPLFA30F-24
INPUT
VOLTAGE[V] AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.1)
*3
CURRENT[A]
ACIN 100V
0.65typ (Io=100%)
ACIN 200V
0.35typ (Io=100%)
FREQUENCY[Hz] 50 / 60 (47 - 440)
EFFICIENCY[%]
ACIN 100V
75.0typ 78.0typ 81.0typ
ACIN 200V
77.0typ 80.0typ 83.0typ
INRUSH CURRENT[A]
ACIN 100V
15typ (Io=100%) (At cold start) (Ta=25C)
ACIN 200V
30typ (Io=100%) (At cold start) (Ta=25C)
LEAKAGE CURRENT[mA] 0.30 / 0.65max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
OUTPUT
VOLTAGE[V] 51224
CURRENT[A] 6.0 2.5 1.3
LINE REGULATION[mV]
*5
20max 48max 96max
LOAD REGULATION[mV]
*5
100max 100max 150max
RIPPLE[mVp-p]
0 to +50C
*1
100max 120max 120max
-10 - 0C
*1
140max 160max 160max
RIPPLE NOISE[mVp-p]
0 to +50C
*1
250max 250max 250max
-10 - 0C
*1
300max 300max 300max
TEMPERATURE REGULATION[mV]
0 to +50C
50max 120max 240max
-10 to +50
C
60max 150max 290max
DRIFT[mV]
*
2
20max 48max 96max
ST ART -UP TIME[ms] 150typ (ACIN 100V, Io=100%)
HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)
OUTPUT V OL T AGE SETTING[V]
4.90 to 5.30 11.50 to 12.50 23.00 to 25.00
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
5.75 to 7.00 13.80 to 16.80 27.60 to 33.60
OPERATING INDICATION LED (Green)
REMOTE SENSING Not provided
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
ENVIRONMENT
OPERA TING TEMP .,HUMID.AND AL TITUDE
-10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
*3
STORAGE TEMP .,HUMID.AND AL TITUDE
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS DEN-AN
CONDUCTED NOISE/POWER
Complies with DEN-AN
HARMONIC ATTENUATOR
*
4
Complies with IEC61000-3-2 class A (Not built-in to active fi lter)
OTHERS CASE SIZE/WEIGHT 61X36X150mm [2.40X1.42X5.91 inches] (WXHXD) / 370g max
COOLING METHOD Convection
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*3 Derating is required.
*4 When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us about another class.
*5 Please contact us about dynamic load and input response.
* To meet the specifi cations. Do not operate over-loaded condition.
* Parallel operation is not possible.
* Derating is required when operated with chassis and cover.
* Sound noise may be generated by power supply in case of pulse load.
SPLFA
mesplfa.indd2me splfa indd 2 2015/06/1815:00:472015/06/18 15:00:47