Data Sheet September 7, 2012 EVW020A0A Series (Eighth-Brick) DC-DC Converter Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current Features RoHS Compliant Applications Compliant to RoHS EU Directive 2002/95/EC (-Z versions) Compliant to ROHS EU Directive 2002/95/EC with lead solder exemption (non-Z versions) Compliant to IPC-9592, Category 2, Class II High efficiency 92% at 5.0V full load (Vin=48Vdc) Industry standard, DOSA compliant footprint 58.4 mm x 22.8 mm x 8.1 mm (2.30 in x 0.9 in x 0.32 in) Wide input voltage range: 36-75 Vdc Tightly regulated output Constant switching frequency Distributed Power Architectures Positive remote On/Off logic Wireless Networks Input under/over voltage protection Output overcurrent and overvoltage protection Over-temperature protection Remote sense No reverse current during output shutdown Output Voltage adjust: 80% to 110% of Vo,nom Wide operating temperature range (-40C to 85C) UL*Recognized to UL60950-1, CAN/CSA C22.2 No.60950-1, and EN60950-1(VDE 0805-1) Licensed CE mark meets 2006/95/EC directive Meets the voltage and current requirements for ETSI 300-132-2 and complies with and licensed for Basic insulation rating per EN60950-1 2250 Vdc Isolation tested in compliance with IEEE 802.3 PoE standards ISO 9001 and ISO 14001 certified manufacturing facilities Access and Optical Network Equipment Enterprise Networks including Power over Ethernet (PoE) Options Negative Remote On/Off logic Over current/Over temperature/Over voltage protections (Auto-restart) Heat plate version (-H) Surface Mount version (-S) ** Description The EVW020A0A, Eighth-brick low-height power module is an isolated dc-dc converters that can deliver up to 20A of output current and provide a precisely regulated output voltage of 5.0V over a wide range of input voltages (VIN = 36 75Vdc). The modules achieve typical full load efficiency of 92%. The open frame modules construction, available in both surface-mount and through-hole packaging, enable designers to develop cost and space efficient solutions. Standard features include remote On/Off, remote sense, output voltage adjustment, overvoltage, overcurrent and overtemperature protection. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. This product is intended for integration into end-user equipment . All of the required procedures of end-use equipment should be followed. IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Incorporated. ** ISO is a registered trademark of the International Organization of Standards Document No: DS08-001 ver. 1.08 PDF name: EVW020A0A.pdf Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Continuous All VIN -0.3 80 Vdc Transient, operational (100 ms) All VIN,trans -0.3 100 Vdc All TA -40 85 C Storage Temperature All Tstg -55 125 C I/O Isolation voltage (100% factory Hi-Pot tested) All 2250 Vdc Input Voltage Operating Ambient Temperature (see Thermal Considerations section) Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Operating Input Voltage Maximum Input Current (VIN= VIN, min to VIN, max, IO=IO, max) Input No Load Current (VIN = VIN, nom, IO = 0, module enabled) Input Stand-by Current Device Symbol Min Typ Max Unit All VIN 36 48 75 Vdc All IIN,max 3.0 3.5 Adc All IIN,No load 70 IIN,stand-by 2.5 All (VIN = VIN, nom, module disabled) 2 It mA 5.0 mA 0.5 As 2 Inrush Transient All Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1H source impedance; VIN, min to VIN, max, IO= IOmax ; See Test configuration section) All 20 mAp-p Input Ripple Rejection (120Hz) All 65 dB CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 6 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer's data sheet for further information. LINEAGE POWER 2 Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current Electrical Specifications (continued) Parameter Device Symbol Min Typ Max Unit All VO, set 4.90 5.0 5.10 Vdc All VO 4.85 5.15 Vdc All All All 0.2 0.2 0.2 % VO, set % VO, set % VO, set All 15 25 mVrms All 40 75 mVpk-pk Nominal Output Voltage Set-point VIN=VIN, min, IO=IO, max, TA=25C) Output Voltage (Over all operating input voltage, resistive load, and temperature conditions until end of life) Output Regulation Temperature (Tref=TA, min to TA, max) Line (VIN=VIN, min to VIN, max) Load (IO=IO, min to IO, max) Output Ripple and Noise on nominal output (VIN=VIN, nom ,IO= IO, max , TA=TA, min to TA, max) RMS (5Hz to 20MHz bandwidth) Peak-to-Peak (5Hz to 20MHz bandwidth) External Capacitance All CO, max 0 10,000 F Output Current Output Current Limit Inception (Hiccup Mode ) (VO= 90% of VO, set) Output Short-Circuit Current (VO250mV) ( Hiccup Mode ) Efficiency All Io 0 20 Adc All IO, lim 105 120 130 % Io All IO, s/c 5 Arms VIN= VIN, nom, TA=25C, IO=IO, max , VO= VO,set All 92.0 % VIN= VIN, nom, TA=25C, IO=0.5xIO, max , VO= VO,set All 91.0 % All fsw 400 kHz All Vpk 3 % VO, set All ts 200 s All Vpk 5 % VO, set All ts 200 s Unit Switching Frequency Dynamic Load Response (dIo/dt=0.1A/s; VIN = VIN, nom; TA=25C) Load Change from Io= 50% to 75% or 25% to 50% of Io,max Peak Deviation Settling Time (Vo<10% peak deviation) (dIo/dt=1.0A/s; VIN = VIN, nom; TA=25C) Load Change from Io= 50% to 75% or 25% to 50% of Io,max Peak Deviation Settling Time (Vo<10% peak deviation) Isolation Specifications Parameter Device Symbol Min Typ Max Isolation Capacitance All Ciso 2000 pF Isolation Resistance All Riso 100 M I/O Isolation Voltage (100% factory Hi-pot tested) All All 2250 Vdc Device Symbol Min Typ Max General Specifications Parameter Calculated Reliability based upon Telcordia SR-332 Issue 2: Method I Case 3 (IO=80%IO, max, TA=40C, airflow = 200 lfm, 90% confidence) All FIT 272.1 10 /Hours All MTBF 3,675,359 Hours Weight (Open Frame) All Weight (with Heatplate) All LINEAGE POWER Unit 9 21 (0.77) 33 (1.16) g (oz.) g (oz.) 3 Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Device Symbol Min Typ Max Unit Remote On/Off Signal Interface (VIN=VIN, min to VIN, max ; open collector or equivalent, Signal referenced to VIN- terminal) Negative Logic: device code suffix "1" Logic Low = module On, Logic High = module Off Positive Logic: No device code suffix required Logic Low = module Off, Logic High = module On Logic Low - Remote On/Off Current All Ion/off 0.3 1.0 mA Logic Low - On/Off Voltage All Von/off -0.7 1.2 Vdc Logic High Voltage - (Typ = Open Collector) All Von/off 5 Logic High maximum allowable leakage current All Ion/off 10 A All Tdelay 50 msec All Tdelay 50 msec All Trise 5 12 msec 3 % VO, set Vdc Turn-On Delay and Rise Times o (IO=IO, max , VIN=VIN, nom, TA = 25 C) Case 1: Input power is applied for at least 1 second and then the On/Off input is set from OFF to ON (Tdelay = from instant at which VIN=VIN, min until VO = 10% of VO, ) Case 2: On/Off input is set to Logic Low (Module ON) and then input power is applied (Tdelay from instant at which VIN = VIN, min until Vo=10% of VO,set) Output voltage Rise time (time for Vo to rise from 10% of Vo,set to 90% of Vo, set) Output voltage overshoot - Startup o IO= IO, max; VIN=VIN, min to VIN, max, TA = 25 C All Remote Sense Range All Output Voltage Adjustment Range All VSENSE 80 10 % VO, set 110 % VO, set Vdc Output Overvoltage Protection All VO, limit 5.75 7.0 Overtemperature Protection - Hiccup Auto Restart All Tref 130 Input Undervoltage Lockout All VUVLO O C Turn-on Threshold 33 36 Vdc Turn-off Threshold 27 28 32 Vdc Hysterisis 3 5.5 Vdc LINEAGE POWER 4 Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current Characteristic Curves o 88 85 Vin=75V 82 Vin=48V 79 Vin=36V 76 73 70 0 5 10 15 20 VO (V) (200mV/div) 91 Io(A) (5A/div) EFFICIENCY, (%) 94 OUTPUT CURRENT OUTPUT VOLTAGE The following figures provide typical characteristics for the EVW020A0A (5.0V, 20A) at 25 C. The figures are identical for either positive or negative remote On/Off logic. OUTPUT CURRENT, IO (A) TIME, t (200s/div) On/Off VOLTAGE VOn/Off (V) (5V/div) VO (V) (2V/div) Figure 4. Transient Response to 1.0A/S Dynamic Load Change from 50% to 75% to 50% of full load. OUTPUT VOLTAGE VO (V) (10mV/div) OUTPUT VOLTAGE Figure 1. Converter Efficiency versus Output Current. TIME, t (20ms/div) TIME, t (1s/div) TIME, t (100s/div) Figure 3. Transient Response to 0.1A/S Dynamic Load Change from 50% to 75% to 50% of full load. LINEAGE POWER INPUT VOLTAGE VIN (V) (20V/div) VO (V) (2V/div) Figure 5. Typical Start-up Using Remote On/Off, negative logic version shown (VIN = VIN,NOM, Io = Io,max). OUTPUT VOLTAGE VO (V) (100mV/div) Io(A) (5A/div) OUTPUT CURRENT OUTPUT VOLTAGE Figure 2. Typical output ripple and noise (VIN = VIN,NOM, Io = Io,max). TIME, t (20ms/div) Figure 6. Typical Start-up Using Input Voltage (VIN = VIN,NOM, Io = Io,max). 5 Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current Test Configurations Design Considerations Input Filtering CURRENT PROBE TO OSCILLOSCOPE LTEST Vin+ 12H BATTERY 33-100F CS 220F E.S.R.<0.1 @ 20C 100kHz Safety Considerations Vin- NOTE: Measure input reflected ripple current with a simulated source inductance (LTEST ) of 12H. Capacitor CS offsets possible battery impedance. Measure current as shown above. Figure 7. Input Reflected Ripple Current Test Setup. COPPER STRIP V O (+) RESISTIVE LOAD 1uF 10uF SCOPE V O (- ) GROUND PLANE NOTE: All voltage measurements to be taken at the module terminals, as shown above. If sockets are used then Kelvin connections are required at the module terminals to avoid measurement errors due to socket contact resistance. Figure 8. Output Ripple and Noise Test Setup. Rdistribution Rcontact Rcontact Vin+ Rdistribution RLOAD VO Rcontact Rcontact Vin- Rdistribution Vout+ VIN Rdistribution Vout- NOTE: All voltage measurements to be taken at the module terminals, as shown above. If sockets are used then Kelvin connections are required at the module terminals to avoid measurement errors due to socket contact resistance. Figure 9. Output Voltage and Efficiency Test Setup. VO. IO Efficiency = LINEAGE POWER VIN. IIN x 100 % The power module should be connected to a low ac-impedance source. Highly inductive source impedance can affect the stability of the power module. For the test configuration in Figure 7 a 33100F electrolytic capacitor (ESR<0.7 at 100kHz), mounted close to the power module helps ensure the stability of the unit. Consult the factory for further application guidelines. For safety-agency approval of the system in which the power module is used, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standard, i.e. UL60950-1, CSA C22.2 No.60950-1, and VDE0805-1(IEC60950-1). If the input source is non-SELV (ELV or a hazardous voltage greater than 60 Vdc and less than or equal to 75Vdc), for the module's output to be considered as meeting the requirements for safety extra-low voltage (SELV), all of the following must be true: The input source is to be provided with reinforced insulation from any other hazardous voltages, including the ac mains. One VIN pin and one VOUT pin are to be grounded, or both the input and output pins are to be kept floating. The input pins of the module are not operator accessible. Another SELV reliability test is conducted on the whole system (combination of supply source and subject module), as required by the safety agencies, to verify that under a single fault, hazardous voltages do not appear at the module's output. Note: Do not ground either of the input pins of the module without grounding one of the output pins. This may allow a non-SELV voltage to appear between the output pins and ground. The power module has extra-low voltage (ELV) outputs when all inputs are ELV. All flammable materials used in the manufacturing of these modules are rated 94V-0, or tested to the UL60950 A.2 for reduced thickness. For input voltages exceeding -60 Vdc but less than or equal to -75 Vdc, these converters have been evaluated to the applicable requirements of BASIC INSULATION between secondary DC MAINS DISTRIBUTION input (classified as TNV-2 in Europe) and unearthed SELV outputs. The input to these units is to be provided with a maximum 6 A fast-acting fuse in the ungrounded lead. 6 Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current Feature Description Remote On/Off Two remote on/off options are available. Positive logic turns the module on during a logic high voltage on the ON/OFF pin, and off during a logic low. Negative logic remote On/Off, device code suffix "1", turns the module off during a logic high and on during a logic low. increase the power output of the module. Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power (Maximum rated power = Vo,set x Io,max). SENSE(+) SENSE(-) SUPPLY Vin+ Vout+ II VI(+) VO(+) VI(-) VO(-) CONTACT RESISTANCE IO LOAD CONTACT AND DISTRIBUTION LOSSE Figure 11. Circuit Configuration for remote sense . Ion/off ON/OFF TRIM Von/off Vin- Vout- Figure 10. Remote On/Off Implementation. To turn the power module on and off, the user must supply a switch (open collector or equivalent) to control the voltage (Von/off) between the ON/OFF terminal and the VIN(-) terminal (see Figure 10). Logic low is 0V Von/off 1.2V. The maximum Ion/off during a logic low is 1mA, the switch should be maintain a logic low level whilst sinking this current. During a logic high, the typical maximum Von/off generated by the module is 15V, and the maximum allowable leakage current at Von/off = 5V is 1A. If not using the remote on/off feature: For positive logic, leave the ON/OFF pin open. For negative logic, short the ON/OFF pin to VIN(-). Remote Sense Remote sense minimizes the effects of distribution losses by regulating the voltage at the remote-sense connections (See Figure 11). The voltage between the remote-sense pins and the output terminals must not exceed the output voltage sense range given in the Feature Specifications table: [VO(+) - VO(-)] - [SENSE(+) - SENSE(-)] 0.5 V Although the output voltage can be increased by both the remote sense and by the trim, the maximum increase for the output voltage is not the sum of both. The maximum increase is the larger of either the remote sense or the trim. The amount of power delivered by the module is defined as the voltage at the output terminals multiplied by the output current. When using remote sense and trim, the output voltage of the module can be increased, which at the same output current would LINEAGE POWER Input Undervoltage Lockout At input voltages below the input undervoltage lockout limit, the module operation is disabled. The module will only begin to operate once the input voltage is raised above the undervoltage lockout turn-on threshold, VUV/ON. Once operating, the module will continue to operate until the input voltage is taken below the undervoltage turn-off threshold, VUV/OFF. Overtemperature Protection To provide protection under certain fault conditions, the unit is equipped with a thermal shutdown circuit. The unit will shutdown if the thermal reference point o Tref (Figure 13), exceeds 130 C (typical), but the thermal shutdown is not intended as a guarantee that the unit will survive temperatures beyond its rating. The module will automatically restart upon cool-down to a safe temperature. Output Overvoltage Protection The output over voltage protection scheme of the modules has an independent over voltage loop to prevent single point of failure. This protection feature latches in the event of over voltage across the output. Cycling the on/off pin or input voltage resets the latching protection feature. If the auto-restart option (4) is ordered, the module will automatically restart upon an internally programmed time elapsing. Overcurrent Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current-limiting circuitry and can endure current limiting continuously. At the point of current-limit inception, the unit enters hiccup mode. If the unit is not configured with auto-restart, then it will latch off following the over current condition. The module can be restarted by cycling the dc input power for at least 7 Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current Feature Descriptions (continued) one second or by toggling the remote on/off signal for at least one second. If the unit is configured with the auto-restart option (4), it will remain in the hiccup mode as long as the overcurrent condition exists; it operates normally, once the output current is brought back into its specified range. The average output current during hiccup is 10% IO, max. Output Voltage Programming Trimming allows the output voltage set point to be increased or decreased, this is accomplished by connecting an external resistor between the TRIM pin and either the VO(+) pin or the VO(-) pin. VIN(+) 5.11 Vo , set (100 %) 511 Rtrim up 10 .22 1 . 225 % % Where V V o , set % desired V o , set 100 For example, to trim-up the output voltage of the module by 5% to 5.25V, Rtrim-up is calculated is as follows: % 5 R trim up 5 . 11 5 . 0 (100 5 ) 511 10 . 22 1 . 225 5 5 Rtrim up 325 .6 VO(+) Rtrim-up ON/OFF LOAD VOTRIM Rtrim-down VIN(-) determines the required external resistor value to obtain a percentage output voltage change of %: VO(-) Figure 12. Circuit Configuration to Trim Output Voltage. Connecting an external resistor (Rtrim-down) between the TRIM pin and the VO(-) (or Sense(-)) pin decreases the output voltage set point. To maintain set point accuracy, the trim resistor tolerance should be 1.0%. The following equation determines the required external resistor value to obtain a percentage output voltage change of % The voltage between the VO(+) and VO(-) terminals must not exceed the minimum output overvoltage protection value shown in the Feature Specifications table. This limit includes any increase in voltage due to remote-sense compensation and output voltage set-point adjustment trim. Although the output voltage can be increased by both the remote sense and by the trim, the maximum increase for the output voltage is not the sum of both. The maximum increase is the larger of either the remote sense or the trim. The amount of power delivered by the module is defined as the voltage at the output terminals multiplied by the output current. When using remote sense and trim, the output voltage of the module can be increased, which at the same output current would increase the power output of the module. Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power (Maximum rated power = VO,set x IO,max). 511 10 . 22 R trim down % Where % V o , set V desired V o , set 100 For example, to trim-down the output voltage of the module by 8% to 4.6V, Rtrim-down is calculated as follows: % 8 511 Rtrim down 10 .22 8 R trim down 53 . 6 Connecting an external resistor (Rtrim-up) between the TRIM pin and the VO(+) (or Sense (+)) pin increases the output voltage set point. The following equation LINEAGE POWER 8 Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current Thermal Considerations Considerations include ambient temperature, airflow, module power dissipation, and the need for increased reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The thermal data presented here is based on physical measurements taken in a wind tunnel. The thermal reference point, Tref used in the specifications for open frame modules is shown in Figure 13. For reliable operation this temperature o should not exceed 114 C. The thermal reference point, Tref used in the specifications for modules with heatplate is shown in Figure 14. For reliable operation this temperature o should not exceed 105 C. AIRFLOW 16 3.0 m/s (600 LM) 12 2.0 m/s (400 LM) 1.0 m/s (200 LM) 8 0.5 m/s (100 LM) 4 NC 0 20 30 40 50 60 70 80 90 o AMBIENT TEMEPERATURE, TA ( C) Figure 15. Output Current Derating for the Open Frame Module; Airflow in the Transverse Direction from Vout(+) to Vout(-); Vin =48V. 20 OUTPUT CURRENT, IO (A) The power modules operate in a variety of thermal environments; however, sufficient cooling should be provided to help ensure reliable operation. OUTPUT CURRENT, IO (A) 20 16 3.0 m/s (600 LFM) 12 2.0 m/s (400 LFM) 8 1.0 m/s (200 LFM) 0.5 m/s (100 LFM) 4 NC 0 20 Figure 13. Tref Temperature Measurement Location for Open Frame Module. 30 40 50 60 70 80 90 o AMBIENT TEMEPERATURE, TA ( C) Figure 16. Output Current Derating for the Module with Heatplate; Airflow in the Transverse Direction from Vout(+) to Vout(-); Vin =48V. AIRFLOW Figure 14. Tref Temperature Measurement Location for Module with Heatplate. Heat Transfer via Convection Increased airflow over the module enhances the heat transfer via convection. Derating curves showing the maximum output current that can be delivered by each module versus local ambient temperature (TA) for natural convection and up to 3m/s (600 ft./min) forced airflow are shown in Figure 14. LINEAGE POWER OUTPUT CURRENT, IO (A) 20 16 3.0 m/s (600 LFM) 12 2.0 m/s (400 LFM) 1.0 m/s (200 LFM) 0.5 m/s (100 LFM) 8 4 NC 0 20 30 40 50 60 70 80 90 o AMBIENT TEMEPERATURE, TA ( C) Figure 17. Output Current Derating for the Module with Heatplate and 0.25 in. heatsink; Airflow in the Transverse Direction from Vout(+) to Vout(-); Vin =48V. 9 Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current product information such as product code, serial number and the location of manufacture. Thermal Considerations (continued) OUTPUT CURRENT, IO (A) 20 16 12 2.0 m/s (400 LFM) 1.0 m/s (200 LFM) 0.5 m/s (100 LFM) 8 4 NC Figure 20. Pick and Place Location. 0 20 30 40 50 60 70 80 90 o AMBIENT TEMEPERATURE, TA ( C) Nozzle Recommendations Figure 18. Output Current Derating for the Module with Heatplate and 0.5 in. heatsink; Airflow in the Transverse Direction from Vout(+) to Vout(-); Vin =48V. The module weight has been kept to a minimum by using open frame construction. Even so, these modules have a relatively large mass when compared to conventional SMT components. Variables such as nozzle size, tip style, vacuum pressure and placement speed should be considered to optimize this process. The minimum recommended nozzle diameter for reliable operation is 6mm. The maximum nozzle outer diameter, which will safely fit within the allowable component spacing, is 9 mm. Oblong or oval nozzles up to 11 x 9 mm may also be used within the space available. OUTPUT CURRENT, IO (A) 20 16 2.0 m/s (400 LFM) 1.0 m/s (200 LFM) 0.5 m/s (100 LFM) 12 8 NC 4 0 20 30 40 50 60 70 80 90 o AMBIENT TEMEPERATURE, TA ( C) Figure 19. Output Current Derating for the Module with Heatplate and 1.0 in. heatsink; Airflow in the Transverse Direction from Vout(+) to Vout(-); Vin =48V. Please refer to the Application Note "Thermal Characterization Process For Open-Frame BoardMounted Power Modules" for a detailed discussion of thermal aspects including maximum device temperatures. Surface Mount Information Pick and Place The EVW020A0A modules use an open frame construction and are designed for a fully automated assembly process. The modules are fitted with a label designed to provide a large surface area for pick and place operations. The label meets all the requirements for surface mount processing, as well as safety standards, and is able to withstand reflow temperatures of up to 300oC. The label also carries LINEAGE POWER The surface mountable modules in the EVW family use our newest SMT technology called "Column Pin" (CP) connectors. Figure 48 shows the new CP connector before and after reflow soldering onto the end-board assembly. EV W Bo ard In su lato r So lde r Ba ll End assem bly P CB Figure 21. Column Pin Connector Before and After Reflow Soldering . The CP is constructed from a solid copper pin with an integral solder ball attached, which is composed of tin/lead (Sn/Pb) solder for non-Z codes, or Sn/Ag3/Cu (SAC) solder for -Z codes. The CP connector design is able to compensate for large amounts of coplanarity and still ensure a reliable SMT solder joint. o Typically, the eutectic solder melts at 183 C (Sn/Pb solder) or 217-218 oC (SAC solder), wets the land, and subsequently wicks the device connection. Sufficient time must be allowed to fuse the plating on the connection to ensure a reliable 10 Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current Surface Mount Information (continued) Tin Lead Soldering The EVW020A0A power modules are lead free modules and can be soldered either in a lead-free solder process or in a conventional Tin/Lead (Sn/Pb) process. It is recommended that the customer review data sheets in order to customize the solder reflow profile for each application board assembly. The following instructions must be observed when soldering these units. Failure to observe these instructions may result in the failure of or cause damage to the modules, and can adversely affect long-term reliability. In a conventional Tin/Lead (Sn/Pb) solder process peak reflow temperatures are limited to less than o o 235 C. Typically, the eutectic solder melts at 183 C, wets the land, and subsequently wicks the device connection. Sufficient time must be allowed to fuse the plating on the connection to ensure a reliable solder joint. There are several types of SMT reflow technologies currently used in the industry. These surface mount power modules can be reliably soldered using natural forced convection, IR (radiant infrared), or a combination of convection/IR. For reliable soldering the solder reflow profile should be established by accurately measuring the modules CP connector temperatures. 300 235 MAX TEMP SOLDER (C) solder joint. There are several types of SMT reflow technologies currently used in the industry. These surface mount power modules can be reliably soldered using natural forced convection, IR (radiant infrared), or a combination of convection/IR. 240 230 225 220 215 210 205 200 0 10 20 30 40 50 60 o Figure 23. Time Limit Curve Above 205 C for Tin/Lead (Sn/Pb) process Lead Free Soldering The -Z version of the EVW020A0A modules are leadfree (Pb-free) and RoHS compliant and are both forward and backward compatible in a Pb-free and a SnPb soldering process. Failure to observe the instructions below may result in the failure of or cause damage to the modules and can adversely affect long-term reliability. Pb-free Reflow Profile Power Systems will comply with J-STD-020 Rev. C (Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices) for both Pb-free solder profiles and MSL classification procedures. This standard provides a recommended forced-air-convection reflow profile based on the volume and thickness of the package (table 4-2). The suggested Pb-free solder paste is Sn/Ag/Cu (SAC). The recommended linear reflow profile using Sn/Ag/Cu solder is shown in Figure 23. P eak Temp 235oC REFLOW TEMP (C) 250 200 Co o ling zo ne 1-4oCs -1 Heat zo ne max 4oCs -1 MSL Rating The EVW020A0A modules have a MSL rating of 2. 150 100 50 So ak zo ne 30-240s Storage and Handling Tlim above 205oC P reheat zo ne max 4oCs -1 0 REFLOW TIME (S) Figure 22. Reflow Profile for Tin/Lead (Sn/Pb) process LINEAGE POWER The recommended storage environment and handling procedures for moisture-sensitive surface mount packages is detailed in J-STD-033 Rev. A (Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount Devices). Moisture barrier bags (MBB) with desiccant are required for MSL ratings of 2 or greater. These sealed packages should not be broken until time of use. Once the original package is broken, the floor life of the product at conditions of 30C and 60% relative humidity varies according to the MSL rating (see J-STD-033A). The shelf life for dry packed SMT packages will be a minimum of 12 months from the bag seal date, when stored at the following conditions: < 40 C, < 90% relative humidity. 11 Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current Surface Mount Information (continued) 300 Per J-STD-020 Rev. C Peak Temp 260C Reflow Temp (C) 250 200 * Min. Time Above 235C 15 Seconds 150 Heating Zone 1C/Second Cooling Zone *Time Above 217C 60 Seconds 100 50 0 Reflow Time (Seconds) Figure 24. Recommended linear reflow profile using Sn/Ag/Cu solder. Post Solder Cleaning and Drying Considerations Through-Hole Lead-Free Soldering Information The RoHS-compliant through-hole products use the SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant components. They are designed to be processed through single or dual wave soldering machines. The pins have an RoHS-compliant finish that is compatible with both Pb and Pb-free wave soldering processes. A maximum preheat rate of 3C/s is suggested. The wave preheat process should be such that the temperature of the power module board is kept below 210C. For Pb solder, the recommended pot temperature is 260C, while the Pb-free solder pot is 270C max. Not all RoHS-compliant through-hole products can be processed with paste-through-hole Pb or Pb-free reflow process. If additional information is needed, please consult with your Lineage Power representative for more details. Post solder cleaning is usually the final circuit-board assembly process prior to electrical board testing. The result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit-board assembly. For guidance on appropriate soldering, cleaning and drying procedures, refer to Lineage Power Board Mounted Power Modules: Soldering and Cleaning Application Note (AN04-001). LINEAGE POWER 12 Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current EMC Considerations The circuit and plots in Figure 25 shows a suggested configuration to meet the conducted emission limits of EN55022 Class B. Level [dBV] 80 70 60 50 + 40 30 20 10 0 150k + + MES MES Level 300k 500k 1M 2M 3M 4M 5M Frequency [Hz] CE1204081008_fin CE1204081008_pre 7M 10M 30M AV AV [dBV] 80 70 60 50 40 30 x 20 10 0 150k x x MES MES 300k 500k 1M 2M 3M 4M 5M Frequency [Hz] CE1204081008_fin CE1204081008_pre 7M 10M 30M QP PK Figure 25. EMC Considerations For further information on designing for EMC compliance, please refer to the FLT007A0 data sheet (DS05-028). LINEAGE POWER 13 Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current Mechanical Outline for Through-Hole Module Dimensions are in millimeters and [inches]. Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (Unless otherwise indicated) x.xx mm 0.25 mm [x.xxx in 0.010 in.] Top side label includes Lineage Power name, product designation and date code. Top View* Side View *For optional pin lengths, see Table 2, Device Coding Scheme and Options Bottom View Pin 1 2 3 4 5 6 7 8 Function Vi(+) ON/OFF Vi(-) Vo(-) SENSE(-) TRIM SENSE(+) Vo(+) LINEAGE POWER 14 Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current Mechanical Outline for Surface Mount Module (-S Option) Dimensions are in millimeters and [inches]. Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (Unless otherwise indicated) x.xx mm 0.25 mm [x.xxx in 0.010 in.] * Top side label includes Lineage Power name, product designation and date code. Top View* Side View Bottom View Pin 1 2 3 4 5 6 7 8 LINEAGE POWER Function Vi(+) ON/OFF Vi(-) Vo(-) SENSE(-) TRIM SENSE(+) Vo(+) 15 Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current Mechanical Outline for Through-Hole Module with Heat Plate (-H Option) Dimensions are in millimeters and [inches]. Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (Unless otherwise indicated) x.xx mm 0.25 mm [x.xxx in 0.010 in.] Top View Side View *For optional pin lengths, see Table 2, Device Coding Scheme and Options * Bottom side label includes Lineage Power name, product designation and date code. Bottom View* Pin 1 2 3 4 5 6 7 8 LINEAGE POWER Function Vi(+) ON/OFF Vi(-) Vo(-) SENSE(-) TRIM SENSE(+) Vo(+) 16 Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current Recommended Layout Dimensions are in millimeters and [inches]. Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (Unless otherwise indicated) x.xx mm 0.25 mm [x.xxx in 0.010 in.] Pin 1 2 3 4 5 6 7 8 Function Vi(+) ON/OFF Vi(-) Vo(-) SENSE(-) TRIM SENSE(+) Vo(+) SMT Recommended Pad Layout (Component Side View) Pin Function 1 Vi(+) 2 ON/OFF 3 Vi(-) 4 Vo(-) 5 SENSE(-) 6 TRIM 7 SENSE(+) 8 Vo(+) NOTES: FOR 0.030" X 0.025" RECTANGULAR PIN, USE 0.050" PLATED THROUGH HOLE DIAMETER FOR 0.62 DIA" PIN, USE 0.076" PLATED THROUGH HOLE DIAMETER TH Recommended Pad Layout (Component Side View) LINEAGE POWER 17 Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current Packaging Details The surface mount versions of the EVW020A0A (suffix -S) are supplied as standard in the plastic trays shown in Figure 26. Each tray contains a total of 12 power modules. The trays are self-stacking and each shipping box for the EVW020A0A (suffix -S) surface mount module will contain 4 full trays plus one empty hold down tray giving a total number of 48 power modules. Tray Specification Material Max surface resistivity Color Capacity Antistatic coated PVC 1012/sq Clear 12 power modules Figure 26. Surface Mount Packaging Tray LINEAGE POWER 18 Data Sheet September 7, 2012 EVW020A0A Series Eighth-Brick Power Modules 36-75Vdc Input; 5.0Vdc Output; 20A Output Current Ordering Information Please contact your Lineage Power Sales Representative for pricing, availability and optional features. Table 1. Device Codes Product Codes Output Voltage Input Voltage Output Current On/Off Logic Connector Type Comcodes EVW020A0A41Z 48V (36-75Vdc) 5.0V 20A Negative Through hole CC109141826 EVW020A0A641Z 48V (36-75Vdc) 5.0V 20A Negative Through hole CC109166385 EVW020A0A841Z 48V (36-75Vdc) 5.0V 20A Negative Through hole CC109161386 EVW020A0A41-HZ 48V (36-75Vdc) 5.0V 20A Negative Through hole CC109147427 EVW020A0A641-HZ 48V (36-75Vdc) 5.0V 20A Negative Through hole CC109172342 EVW020A0A41-SZ 48V (36-75Vdc) 5.0V 20A Negative Surface mount CC109147435 Ratings Table 2. Device Coding Scheme and Options Characteristic Form Factor Family Designator Input Voltage Output Current Output Voltage Pin Length Character and Position E V W W = Wide Input Voltage Range, 36V -75V 020A0 = 020.0 Amps Rated Output Current A = 5.0 Vout Nominal Omit = Default Pin Length shown in Mechanical Outline Figures 6 = Pin Length: 3.68 mm 0.25mm , (0.145 in. 0.010 in.) 8 = Pin Length: 2.79 mm 0.25mm , (0.110 in. 0.010 in.) Omit = Latching Mode 4 = Auto-restart following shutdown (Overcurrent/Overvoltage) Omit = Positive Logic 1 = Negative Logic 020A0 A 6 8 Action following Protective Shutdown Options Definition E = Eighth Brick On/Off logic Customer Specific Mechanical Features RoHS 4 1 XY XY = Customer Specific Modified Code, Omit for Standard Code Omit = Standard open Frame Module H H = Heat plate (not available with -S option) S S = Surface mount connections Omit = RoHS 5/6, Lead Based Solder Used Z Z = RoHS 6/6 Compliant, Lead free Asia-Pacific Headquarters Tel: +86.021.54279977*808 World Wide Headquarters Lineage Power Corporation 601 Shiloh Road, Plano, TX 75074, USA +1-888-LINEAGE(546-3243) (Outside U.S.A.: +1-972-244-WATT(9288)) www.lineagepower.com e-mail: techsupport1@lineagepower.com Europe, Middle-East and Africa Headquarters Tel: +49.89.878067-280 India Headquarters Tel: +91.80.28411633 Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Lineage Power DC-DC products are protected under various patents. Information on these patents is available at www.lineagepower.com/patents. (c) 2010 Lineage Power Corporation, (Plano, Texas) All International Rights Reserved. Document No: DS08-001 ver. 1.08 PDF name: evw020_ds.pdf