https://www.phoenixcontact.com/us/products/2708096 FO converters-PSI-MOS-DNET CAN/FO 850/EM-2708096 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) (R) FO converter with integrated optical diagnostics, for DeviceNetTM, CAN, CANopen up to 800 kbps, extension/ redundancy module, interfaces: 1 x FO (BFOC), 850 nm, for PCF/fiberglass cable (multimode) Product Description The PSI-MOS-DNET... fiber optic transmission system enables DeviceNetTM and CANopen(R) users to benefit from simple and interference-free networking based on fiber optics. In addition, bus cable short circuits only affect the specific potential segment concerned. This increases overall availability, and improves flexibility when designing the bus topology. The use of fiber optic technology enables branch lines and star and tree structures to be created. The 22.5 mm space-saving devices from the PSI-MOS-DNET CAN/FO... series feature an internal backplane. The maximum network expansion that can be achieved (sum total of copper and fiber optic cables) essentially depends on the data rate used. Your advantages Integrated optical diagnostics for continuous monitoring of FO paths High-quality electrical isolation between all interfaces (DeviceNet // fiber optic port // power supply // backplane) Integrated bus termination resistor can be connected internally Integrated backplane for routing through the supply voltage and data signals Connections can be plugged in via a COMBICON screw terminal block Floating switch contact in the basic module for leading alarm generation in relation to critical fiber optic paths Key Commercial Data Packing unit 1 pc GTIN GTIN 4017918943219 Weight per Piece (excluding packing) 166.000 g Custom tariff number 85176200 Country of origin Germany 04/19/2021Page1/11 https://www.phoenixcontact.com/us/products/2708096 FO converters-PSI-MOS-DNET CAN/FO 850/EM-2708096 Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Use in potentially explosive areas is not permitted in China. Dimensions Width 22.5 mm Height 99 mm Depth 114.5 mm Ambient conditions Ambient temperature (operation) -20 C ... 60 C Ambient temperature (storage/transport) -40 C ... 85 C Permissible humidity (operation) 30 % ... 95 % (non-condensing) Altitude 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) Degree of protection IP20 Noise immunity EN 61000-6-2:2005 Interfaces Interface 1 CAN interface, in accordance with ISO/IS 11898 for DeviceNet, CAN, CANopen Connection method Pluggable screw connection File format/coding Bit stuffing, NRZ Transmission medium Copper Transmission length 5000 m (Dependent on the data rate and the protocol used) Serial transmission speed 800 kbps Optical interface FO Transmit capacity, minimum -17.9 dBm (50/125 m) -14.1 dBm (62,5/125 m) -5.1 dBm (200/230 m) Minimum receiver sensitivity -32.5 dBm (50/125 m) -32.5 dBm (62,5/125 m) -32.1 dBm (200/230 m) Wavelength 850 nm Transmission length incl. 3 dB system reserve 2800 m (With F-K 200/230 10 dB/km with quick mounting connector) 4800 m (with F-G 50/125 2.5 dB/km) 4200 m (with F-G 62,5/125 3.0 dB/km) Transmission medium PCF fiber Multi-mode fiberglass 04/19/2021Page2/11 https://www.phoenixcontact.com/us/products/2708096 FO converters-PSI-MOS-DNET CAN/FO 850/EM-2708096 Technical data Optical interface FO Connection method (R) B-FOC (ST ) Power supply Nominal supply voltage 24 VDC (in acc. with UL) Supply voltage range 10 VDC ... 30 VDC Max. current consumption 100 mA Typical current consumption 100 mA (24VDC) Connection method Pluggable COMBICON screw terminal block through basic module General Bit distortion, input 35 % (permitted) Bit distortion, output < 6.25 % Electrical isolation VCC // CAN Test voltage data interface/power supply 1.5 kVrms (50Hz, 1min.) Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Noise emission EN 55011 Mounting type DIN rail mounting Net weight 107.98 g Housing material PA 6.6-FR Color green MTBF 323 Years (Telcordia standard, 25C temperature, 21% operating cycle (5 days a week, 8 hours a day)) 49 Years (Telcordia standard, 40C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) Conformance/approvals Designation CE Certificate CE-compliant Designation ATEX Identification II 3 G Ex nA nC IIC T4 Gc X Additional text Please follow the special installation instructions in the documentation! Designation ATEX, FO interface Identification II (2) G [Ex op is Gb] IIC II (2) D [Ex op is Db] IIIC Certificate PTB06ATEX2042U Additional text Please follow the special installation instructions in the documentation! Designation UL, USA/Canada Identification Class I, Zone 2, AEx nc IIC T5 Class I, Div. 2, Groups A, B, C, D 04/19/2021Page3/11 https://www.phoenixcontact.com/us/products/2708096 FO converters-PSI-MOS-DNET CAN/FO 850/EM-2708096 Technical data Conformance/approvals Designation PTB Corrosive gas test Identification ISA-S71.04-1985 G3 Harsh Group A Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Type of test Vibration resistance in acc. with EN60068-2-6/IEC60068-2-6 Test result 5g, 10...150 Hz, 2.5 h, in XYZ direction Type of test Shock in acc. with EN60068-2-27/IEC60068-2-27 Test result 15g, 11 ms period, half-sine shock pulse Noise emission EN 55011 Noise immunity EN 61000-6-2:2005 Connection in acc. with standard CUL Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings Application drawing Application drawing FO FO BE B B BE B FO B ...64x BE Branch line / redundant branch line Branch line / redundant branch line ...64x ...64x Linear structure Line structure 04/19/2021Page4/11 https://www.phoenixcontact.com/us/products/2708096 FO converters-PSI-MOS-DNET CAN/FO 850/EM-2708096 Application drawing BE E E BE BE ...20 Application drawing BE E BE ...20 FO FO BE E BE E BE E FO B B B B BE BE BE B Star structure / redundant star structure Star structure / redundant star structure B B B B B Tree structure Tree structure Block diagram *) Only in the basic module Classifications eCl@ss eCl@ss 10.0.1 19170132 eCl@ss 11.0 19170411 eCl@ss 4.0 27230200 eCl@ss 4.1 27230200 eCl@ss 5.0 27230200 eCl@ss 5.1 27230200 eCl@ss 6.0 19179200 eCl@ss 7.0 19179290 04/19/2021Page5/11 https://www.phoenixcontact.com/us/products/2708096 FO converters-PSI-MOS-DNET CAN/FO 850/EM-2708096 Classifications eCl@ss eCl@ss 9.0 19170114 ETIM ETIM 2.0 EC001423 ETIM 3.0 EC001423 ETIM 4.0 EC001423 ETIM 6.0 EC001467 ETIM 7.0 EC001467 UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 43222604 UNSPSC 18.0 43223323 UNSPSC 19.0 43223323 UNSPSC 20.0 43223323 UNSPSC 21.0 43223323 Accessories Accessories Data cable by the meter FO cable-PSM-LWL-HCS-RUGGED-200/230-2799885 PCF cable, duplex 200m/230m, by the meter without male connector, for installation in stationary systems and machines FO cable-PSM-LWL-HCSO-200/230-2799445 PCF cable, duplex 200/230 m, by the meter, without connector, for outdoor installation 04/19/2021Page6/11 https://www.phoenixcontact.com/us/products/2708096 FO converters-PSI-MOS-DNET CAN/FO 850/EM-2708096 Accessories FO cable-PSM-LWL-GDM-RUGGED- 50/125-2799322 Fiber glass cable, duplex 50m/125m, by the meter, without male connector, for installation in stationary systems and machines FO cable-PSM-LWL-GDO- 50/125-2799432 Fiberglass cable, duplex 50/125 m, by the meter, without connector, for outdoor installation Bus system cable-SAC-5P-920/...-1511504 (R) Bus system cable, CANopen , DeviceNetTM, 4-position, PUR halogen-free, violet RAL 4001, shielded, cable length: Free entry (0.5 ... 400 m) Data cable preassembled FO patch cable-FOC-HCS-RUGGED-1014/IP20/...-2901555 Robust PCF installation cable for assembly (IP20 heads only) for installation in stationary systems and machines, aramid strain relief elements, with individual elements made from FRNC material, halogen-free, ozone and UV resistant, with a polyurethane (PUR) outer sheath FO patch cable-FOC-HCS-RUGGED-1014/...-1402191 rugged PCF installation cable for inner areas with highly tear-proof aramid strain-relief elements. Individual elements made from highly flexible FRNC material. The cable is halogen-free, ozone and UV resistant and has a rugged polyurethane (PUR) outer sheath. 04/19/2021Page7/11 https://www.phoenixcontact.com/us/products/2708096 FO converters-PSI-MOS-DNET CAN/FO 850/EM-2708096 Accessories FO patch cable-FOC-HCSO-1015/IP20/...-2901557 Highly rugged PCF round cable (IP20 heads only) for assembly and for outdoor installation with integrated moisture barrier as well as rodent-proof scrim. Individual elements made from highly flexible FRNC material. The wire is ozone and UV resistant with a very rugged polyethylene outer sheath. FO patch cable-FOC-GDM-RUGGED-1016/IP20/...-2901558 Robust GOF installation cable for assembly (IP20 heads only) for installation in stationary systems and machines, aramid strain-relief elements, with individual elements made from FRNC material, halogen-free, ozone and UV resistant, with a polyurethane (PUR) outer sheath FO patch cable-FOC-GDO-1017/IP20/...-2901559 Highly rugged GOF round cable (IP20 heads only) for assembly and for outdoor installation with integrated moisture barrier as well as rodent-proof scrim. Individual elements made from highly flexible FRNC material. The wire is ozone and UV resistant with a very rugged polyethylene outer sheath. Data plug Assembly tool-PSM-HCS-KONFTOOL/B-FOC-2708465 HCS assembly kit for B-FOC(ST) quick mounting connectors, including stripping blade, stripping pliers, aramide yarn scissors, fiber stripper, microscope, fiber cleaving tool for standard HCS and HCS GI fibers, four B-FOC(ST) connectors for standard HCS fiber, and documentation Measuring instrument-PSM-FO-POWERMETER-2799539 Fiber optic measuring case, consisting of an optical power meter, F-SMA, B-FOC adapters, reference fibers and operating instructions 04/19/2021Page8/11 https://www.phoenixcontact.com/us/products/2708096 FO converters-PSI-MOS-DNET CAN/FO 850/EM-2708096 Accessories Fiber optic coupling-PSM-SET-BFOC-LINK/2-2799429 Coupling; set consisting of 2 couplings for connecting B-FOC plugs D-SUB bus connector-SUBCON-PLUS-CAN-2744694 D-SUB connector, 9-pos. female connector, two cable entries < 35 to one terminal block row, bus system: CAN, (R) CANopen , SafetyBUS p up to 1 Mbps, termination resistor can be switched on via slide switch, pin assignment: 2, 3, 7; screw connection terminal blocks D-SUB bus connector-SUBCON-PLUS-CAN/PG-2708119 (R) D-SUB connector, 9-pos. socket, cable entry < 35, bus system: CAN, CANopen , SafetyBUS p up to 1 Mbps, with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 2, 3, 7, 9; screw terminal blocks D-SUB bus connector-SUBCON-PLUS-CAN/AX-2306566 D-SUB connector, 9-pos. female connector, axial version with two cable entries, bus system: CAN, CANopen, SafetyBUS p; pin assignment: 2, 3, 7; screw connection terminal blocks FO connectors-PSM-SET-B-FOC/4-HCS-2708481 B-FOC (ST) connector set for PCF fiber, for self assembly consisting of 4 quick mounting connectors with bend protection sleeve 04/19/2021Page9/11 https://www.phoenixcontact.com/us/products/2708096 FO converters-PSI-MOS-DNET CAN/FO 850/EM-2708096 Accessories D-SUB bus connector-SUBCON-PLUS-CAN/90/PG/M12-2902322 D-SUB plug, 9-pos., socket, with PG-D-SUB pin, assignment: 2, 3, 5, 6, 7, 9; two M12 cable glands (A-coded) under 90. Bus system: CAN, CANopen(R). Termination resistor via separate M12 terminator. D-SUB bus connector-SUBCON-PLUS-CAN/90/M12-2902323 D-SUB plug, 9-pos., socket, assignment: 2, 3, 5, 6, 7, 9; two M12 cable glands (A-coded) under 90. Bus system: CAN, CANopen(R). Termination resistor via separate M12 terminator. D-SUB bus connector-SUBCON-PLUS-CAN/35/PG/M12-2902324 D-SUB plug, 9-pos., socket, with PG-D-SUB pin, assignment: 2, 3, 5, 6, 7, 9; two M12 cable glands (A-coded) under 35. Bus system: CAN, CANopen(R). Termination resistor via separate M12 terminator. D-SUB bus connector-SUBCON-PLUS-CAN/35/M12-2902325 D-SUB plug, 9-pos., socket, assignment: 2, 3, 5, 6, 7, 9; two M12 cable glands (A-coded) under 35. Bus system: CAN, CANopen(R). Termination resistor via separate M12 terminator. D-SUB bus connector-SUBCON-PLUS-CAN/AX/M12-2902326 D-SUB plug, 9-pos., socket, assignment: 2, 3, 5, 6, 7, 9; two M12 cable glands (A-coded) under 180 (axial). Bus system: CAN, CANopen(R). Termination resistor via separate M12 terminator. 04/19/2021Page10/11 https://www.phoenixcontact.com/us/products/2708096 FO converters-PSI-MOS-DNET CAN/FO 850/EM-2708096 Accessories D-SUB bus connector-SUBCON-PLUS-CAN-2744694 D-SUB connector, 9-pos. female connector, two cable entries < 35 to one terminal block row, bus system: CAN, (R) CANopen , SafetyBUS p up to 1 Mbps, termination resistor can be switched on via slide switch, pin assignment: 2, 3, 7; screw connection terminal blocks D-SUB bus connector-SUBCON-PLUS-CAN/PG-2708119 (R) D-SUB connector, 9-pos. socket, cable entry < 35, bus system: CAN, CANopen , SafetyBUS p up to 1 Mbps, with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 2, 3, 7, 9; screw terminal blocks D-SUB bus connector-SUBCON-PLUS-CAN/AX-2306566 D-SUB connector, 9-pos. female connector, axial version with two cable entries, bus system: CAN, CANopen, SafetyBUS p; pin assignment: 2, 3, 7; screw connection terminal blocks Screwdriver tools Screwdriver-SZS 0,4X2,5 VDE-1205037 Screwdriver, slot-headed, VDE insulated, size: 0.4 x 2.5 x 80 mm, 2-component grip, with non-slip grip Phoenix Contact 2021 (c) - all rights reserved http://www.phoenixcontact.com 04/19/2021Page11/11