V-Series
Contura Switches
Carling Technologies fully sealed V-Series Contura switches
are well known for their cutting edge design, high quality,
maximum performance and unmatched reliability. These
switches are a staple in the marine and transportation
industries and have passed a range of environmental,
corrosion, temperature, vibration, shock and sealing tests
including MIL Std 202F, MIL Std 810C, UL 1500, ISO 8846, IEC
60529 and BS 5490 among others, making them one of the
most rugged and reliable switches ever manufactured.
Product Highlights:
Maximum sealing protection with dual seals around lamps
and rocker stem, certied to IP66 & IP68. Optional panel
seals for additional protection.
Silver plated butt contact mechanism provides 50 to
100 thousand electrical cycles and a variety of dierent
electrical ratings.
Roller pin mechanism does not require lubricants and
allows the switch to withstand extreme temperatures.
The switch base accommodates up to 10 terminals and a
large variety of switch and lighting circuits.
The multi-step mounting wings provide a secure t for
panel thicknesses of 0.032” thru 0.250” in an industry
standard 0.830” x 1.450” mounting hole.
The switch connector allows the user to preload FQC
terminals for easy assembly to switch base.
Numerous choices of removable rockers allow for style
change without having to retest or re-qualify the switch
base.
Illumination options are endless with bar, oval, and square
lenses available with choices of incandescent, neon and
a wide variety of LEDs including superbrite, megabrite,
ashing and bicolor lighting.
Available with a variety of complimentary mounting
panels, hole plugs, illuminated indicators and boots to
accommodate most any design need.
CONTURA V CONTURA VII
CONTURA III CONTURA II
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: sales@carlingtech.com
Application Support: team2@carlingtech.com
Phone: (860) 793-9281 • Fax: (860) 793-9231
www.carlingtech.com
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
2 |V-Series Contura Sealed Rocker Switches
V-Series Switch
DESIGN FEATURES
INTERCHANGEABLE ACTUATORS
Panel redesign is a snap with our wide
range of rocker styles. Achieve maximum
design variety with minimum inventory.
Simply swap rockers to create an entirely
new look for your panel.
DUAL SEAL PROTECTION
Seals out water, dust,
debris, and enables switch
certication to IP66/IP68 for
front panel components.
CLEAN CONNECTIONS
Options for both eight and ten
terminal base styles with AMP &
Packard compatible connectors
aords myriad circuit options
while providing ease of assembly.
MULTIPLE LIGHTING OPTIONS
In addition to Incandescent
lamps, our LED illumination is
oered in a wide array of light
intensities, colors, as well as
dual level, tri-color, and ashing
options.
BRASS ROLLER PIN
Robust mechanism
eliminates the need for
lubricants. Enables switch
to withstand -40°C to
+85°C temperatures.
OPTIONAL PANEL SEAL
Prevents water/dust
ingress behind panel.
SILVER PLATED BUTT
CONTACT MECHANISM
Providing 50k to 100k
electrical cycles and
a variety of dierent
electrical ratings.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
| 3
V-Series Contura Sealed Rocker Switches & Illuminated Plug
Contura II & III
The Contura II & III actuators are
constructed of thermoplastic
polycarbonate and are oered
with a hard nylon overlay or a
soft-touch elastomer overlay.
These models incorporate
aesthetic designs on the top and
bottom of the rocker featuring
two rows of raised “bumps” on the
Contura II and three “indented
lines on the Contura III.
Contura IV
The Contura IV’s “Shape to create
a Shape” actuator works with the
curves, contours & advanced
styling of the latest panel designs,
owing with these advanced
curves & radii. This actuator style
ts on the Contura ush bracket/
bezel.
Contura V
The symmetrically curved
Contura V actuator provides
the perfect complement to the
Contura IV’s “Shape to create a
Shape” design concept. With its
ush style mounting bracket,
Contura V can be mounted in
between two Contura IV’s, by
itself, or in groups.
Contura VII
Contura VII featuring gently
curved corners and edges
assuring compatibility with most
any panel design. Intuitive feel
is maximized by the use of 2
embossed circular pads located at
opposite ends of the rocker. Any
combination of Bar or Oval style
lenses can be located in the pads
providing a truly unique look,
exclusive to Contura VII.
Contura VI (WAVE)
The Contura VI WAVE sealed
rocker switches, when used in a
row, create an uniquely appealing
“wave design on your panel. A
variety of colors and nishes are
available for both rocker and wave
insert. Contura VI features bar and
oval lenses.
Contura X
The raised bracket/bezel on
the Contura X helps prevent
inadvertent actuation of the
rocker, as well as preventing
debris from being trapped under
the actuator. This curved rocker
style is available with a variety of
lenses and legends.
Contura XI
The raised bracket/bezel on
the Contura XI helps prevent
inadvertent actuation of the
rocker, as well as preventing debris
from being trapped under the
actuator. This convex style rocker
is available with a wide variety of
lenses and legends.
Contura XII
The Contura XII version features
a paddle style actuator with
the raised bracket/bezel of
Contura X and XI. The contoured
handle design provides intuitive
recognition and ease of operation
and is available with all Contura X
and XI lens and legend oerings.
Contura XIV
The Contura XIV represents a sleek
new crossover rocker design which
should appeal to Trucks, Buses and
Heavy Vehicles as well as the Marine
Industry. Intuitive feel is provided by
recessed ridges along with a Center
Groove which eectively denes the
boundary between top and bottom
switch functions.
V-Series Illuminated
Indicators & Accessories
Alert operator of systems functions
or malfunctions, are oered with
removable/replaceable lamps in
Contura II, II, V or X styles. Accessories
include connectors, mounting
panels, hole plugs, panel seals, and
actuator removal tools. Refer to
accessories page for full details
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
4 |V–Series Contura Sealed Rocker Switches - General Specications
1.450[36.83]
.830[21.08]
SWITCH
MOUNTING HOLE
TEST CUT
HOLE IN
ACTUAL
MATERIAL
Panel Thickness Range
Gaskets Acceptable Panel Thickness
0 .030 to .250 (.76mm to 6.35mm)
1 .030 to .109 & .147 to .157
(.76 to 2.77mm & 3.73 to 3.98mm)
Recommended: No gasket with panel
thickness of .032, .062, .093, .125,.187 or .250
Contact Rating .4VA @ 24VDC (MAX) resistive
15 amps, 125VAC
10 amps, 250VAC
1/2 HP 125-250VAC
20 amps, 4-14VDC
15 amps, 15-28VDC
10A, 14VT
6A, 125VAC L
Dielectric Strength 1500 Volts RMS
Insulation Resistance 50 Megohms
Initial Contact Resistance 10 milliohms max. @ 4VDC
Life 50,000- 100,000 cycles circuit
dependent
Contacts Silver alloy, silver tin-oxide, ne
silver
Terminals Brass or copper/silver plate 1/4”
(6.3mm) Quick Connect
terminations standard. Solder lug,
Wire Lead
Endurance 150,000 cycles minimum
circuit dependent
2 position 18°
3 positions 9° from center
Lighted Incandescent - rated 10,000
hours Neon - rated 25,000 hours
LED - rated 100,000 hours 1/2 life
(LED is internally ballasted for
voltages to 24VDC)
Seals Internal
Optional external gasket panel seal
Base Polyester blend rated to 125°C with
a UL ammability rating of 94V0.
Contura II,III,IV,V, Hard Surface: Basic actuator
VI, VII Actuator structure molded of thermoplastic
polycarbonate with a hard Nylon 66
thermoplastic surface overlay.
Soft Surface: Basic actuator structure
molded of thermoplastic polycarbonate
with an elastomer overlay.
Contura X,XI,XII Actuator,VP Nylon 66 Reinforced rated to 105°C
Lens Polycarbonate rated at 100°C
Contura XIV Polycarbonate lens/subrocker with
ABS shell
Sealing Sealed version: IP68, in accordance
with IEC 60529, BS 5490, DIN 40050
& NFC 20 010. This rating applies to
front panel components of the actual
switch only, and signies protection
against dust and the prolonged
effects of immersion under pressure.
The standard test for immersion
under pressure requires submersion
under one meter of water for 30 min.
The V-Series switch has exceeded
these parameters, having
been actuated and illuminated during
submersion.
Corrosion Mixed Flowing Gas (MFG) Class III
3 year accelerated exposure per
ASTM B-827, B-845 Silver and gold
contacts
Operating Temp. -40°C to + 85°C
Vibration 1 Per Mil-Std 202F, Method 204D
Test Condition A 0.06 DA or 10G’s
10-500 Hz. Tested with VCH connector.
Test criteria - No loss of circuit during
test, pre and post test contact
resistance.
Vibration 2 Resonance search
24-50 Hz 0.40 DA
50-2000 Hz ±10 G’s peak
Horizontal Axis 3-5 G’s max.
Random
24 Hz 0.06 PSD-Gsq/Hz
60 Hz 0.50
100 Hz 0.50
200 Hz 0.025
2000 Hz 0.025
No loss of circuit during test; <10μ
seconds chatter.
Shock Per Mil-Std 202F, Method 213B, Test
Condition K @ 30G’s. Tested with
VCH connector. Test criteria - No loss
of circuit during test, pre and post
test contact resistance.
Salt Spray Per Mil-Std 202F, Method 101D, Test
Condition A, 96 Hrs. Sealed version only.
Dust Per Mil-Std 810C, Method 510.2 Air
Velocity 300 ±200 Feet/Min, Test
Duration 16 Hrs.
Thermal Shock Per Mil-Std 202F, Method 107F, Test
Cond. A, -55°C to 85°C. Test criteria -
pre and post test contact resistance
Moisture Resistance Per Mil-Std 202F, Method 106F, Test
Criteria - pre and post test contact
resistance
Ignition Protection All Contura switches with sealed
construction meet the requirements
of UL1500/ISO8846 for ignition
protection, in addition to
conformance with EC directive
94/25/EC for marine products.
Electrical Agency Certifications
Environmental
Mechanical
Actuator Travel (Angular Displacement)
Mounting Specifications
Physical
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
| 5
V–Series Contura II, III, & IV
Dimensional Specifications: in. [mm]
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
6 |V-Series Contura V, VI & VII
1.079
[27.40]
.505
[12.83]
.505
[12.83]
8
1
7
4
78
41
3
6
9
6
3
.250
[6.35]
X
.031
[.78]
.250
[6.35]
X
.031
[.78]
CONTURA V
SHOWN WITH
LOW PROFILE LOCK
8 TERMINAL BASE
W/O BARRIERS
8 TERMINAL BASE
W/O BARRIERS
10
BOTTOM VIEW
TERMINAL
ARRANGEMENT
10 TERMINAL BASE
BOTTOM VIEW
TERMINAL
ARRANGEMENT
8 TERMINAL BASE
.820
[20.83]
1.020
[25.91]
1.479
[37.57]
1.922[48.56]
1.126
.080[2.03]
5
22
5
2.029
[51.53]
CONTURA V
SHOWN WITH
BAR LENS
1.020
[25.91]
1.550
[39.37]
1.922[48.56]
8 TERMINAL BASE
W/BARRIERS
8 TERMINAL BASE
W/BARRIERS
.390
[9.90]
SWITCH SHOWN WITH
VCH CONNECTOR 8
TERMINAL
.960
[24.38] .960
[24.38]
.250
[6.35]
X
.031
[.78]
.820
[20.83]
.960
[24.38]
1.000
[25.40]
1.950[49.53]
SWITCH SHOWN WITH
VC1 CONNECTOR 10
TERMINAL
10 TERMINAL BASE
W/BARRIER AND
LAMP TERMINAL
10 TERMINAL BASE
W/O BARRIERS
CONTURA VI
SHOWN WITH OVAL
LENS
CONTURA VII
SHOWN WITH LARGE LENS
AND BAR LENS
10 TERMINAL BASE
W/O BARRIERS
1.922[48.82]
10 TERMINAL BASE
W/O BARRIERS
0.985
[25.02]
.250 [6.35]
.031 [.78]
.820
[20.83]
.960
[24.38]
SWITCH SHOWN
WITH VC1
CONNECTOR 10
TERMINAL
Dimensional Specifications: in. [mm]
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
| 7
V-Series Contura X, XI, XII & XIV
10 TERMINAL BASE
W/O BARRIERS
CONTURA XI STYLE
SHOWN WITH RAISED
BRACKET AND TWO SQUARE
LENSES
10
8
2
1
9
4
7
63
5
BOTTOM VIEW
TERMINAL
ARRANGEMENT
10 TERMINAL BASE
1
8
2
7
4
5
3 6
BOTTOM VIEW
TERMINAL
ARRANGEMENT
8 TERMINAL BASE
1.506[38.25]
.350[8.89]
1.370[34.79]
10 TERMINAL BASE
W/O BARRIERS
.426[10.82]1.910[48.51]
CONTURA X STYLE
SHOWN WITH RAISED BRACKET
1.586[40.28]
.350
[8.89]
.667 [16.94]
8 TERMINAL BASE
W/BARRIERS
1.910[48.51]
1.370[34.79]
SWITCH SHOWN WITH
VCH CONNECTOR
8 TERMINAL
CONTURA XII STYLE
SHOWN WITH PADDLE
ACTUATOR
CONTURA XIV STYLE
SHOWN WITH LARGE LENS
.390[9.90]
10 TERMINAL BASE
W/BARRIERS
.780[19.81]
.820[20.82]
.960[24.38]
.780[19.81]
10 TERMINAL
BASE
W/O BARRIERS
.390[9.90]
.820[20.82]
.960[24.38]
.250[6.35]
X
.031[.78]
8 TERMINAL BASE
W/BARRIERS
.780[19.81]
.820[20.82]
.390[9.90]
.960[24.38]
SWITCHES SHOWN WITH
VC1 CONNECTOR
10 TERMINAL
8 TERMINAL BASE
W/O BARRIERS
1.305[33.15]
1.370[34.79]
.960
[24.38]
.820
[20.83]
.970
[24.64]
1.928
[48.97]
.573
[14.56]
Dimensional Specifications: in. [mm]
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
25
1346
6431
DEFINITION
CIRCUITCIRCUIT
A J
3
25
3
63
2
34 6
L
M
5
52
K
1
52
D
431
C
3
2
B
5
2
3
CIRCUIT
1
3
3
3
2
2
2
4
1 3
31
R
25
52
13 6
S
6
F
13
E
52
25
3
43
4
1
SYM.
43
25
H
2 5
13
6
13
31
2
2
5
8
2
31
6
CIRCUIT DIAGRAM
2
6
6
6
6
6
6
G
CIRCUIT DIAGRAM
7
52522
CIRCUIT DIAGRAM
SYMBOL LEGEND
DESIGNATES TERMINALS AND CONTACTS
DESIGNATES LAMP LOCATION
DESIGNATES MAINTAINED CIRCUITS
DESIGNATES OTHER POSITION
DESIGNATES MOMENTARY CIRCUITS
DESIGNATES TWO POSITION CONNECTION
DESIGNATES EXTERNAL JUMPER PROVIDED
BY CUSTOMER
8 |V-Series Contura II to XIV - Circuit Diagram
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
| 9
V-Series Contura II to XIV - Circuit Diagram
1
LAMP
CIRCUIT CIRCUIT DIAGRAM
+3
+3 -6
CIRCUIT DIAGRAM
LAMP
CIRCUIT
1
L/9
2
-6
+8 +3
-7
SPECIAL
#4
21
SPECIAL
#1
2
-7
+6+3
1
+6+8
2
SPECIAL
#3
+10
21
2
-4 -6+3+1
1
+8
G/7
F/6
+3
12
+8
1
-7
+8 -6+3
2
CIRCUIT DIAGRAM
LAMP
CIRCUIT
M/R
+8
LAMP
CIRCUIT
1
-7
1
+3
J/8
H/Z
+8
+6
-7
12
-8 +6
2
-7
+3
+8
P/V
N/T
+1 -6+3 -4
11 614
CIRCUIT DIAGRAM
CIRCUIT
JJ
-7 -9
12
11 13 3
D/4
C/3
-7
+1
-7
+3
+3
1
+3
+1
B/2
A/1
12
3110(-)
13 333311 14
JA
5
11 13 314141411 13 3313
14
1
-7
SYM.
13 15 12 6161411 3
JK
333
K/W
2
2
85
J5
CIRCUIT CIRCUIT DIAGRAM
(-)7
2
1311 31311 33311 1311 13
J1
E/5
558822
13
CIRCUIT
J2
17 18 10(-)
1
2
CIRCUIT DIAGRAM
2
2
-7 -7 -7
DESIGNATES TERMINALS AND CONTACTS
DESIGNATES LAMP LOCATION
DEFINITION
SYMBOL LEGEND
17 18
13
852
13
J4
J3
58
5
U/Y
1
17 18 10(-)
17 18 10(-)
1
CIRCUIT DIAGRAM
17 18 10(-)
1
CONNECTOR PART #
16
3
14143
5
CIRCUIT DIAGRAM
14 6
33
14
314
333
JA,JJ,JK
J2
CIRCUIT
J1,J3,J4,J5
228855
3
17 18
58
2
2
10(-) 13
CIRCUIT DIAGRAM
JA
61215333314
8
5
3
SYMBOL LEGEND
DEFINITION
JK
JJ
1
17 18 10(-)
17 18 10(-)
CIRCUIT DIAGRAM
14
31
1311
CIRCUIT
13 11
1113
SYM.
CIRCUIT
J5
1
1
17 18 10(-)
17 18 10(-)
1
1
25
8
2
31
5
JC3-01
JC2-01
JC1-01
J3
J4
J2
CIRCUIT
J1
DESIGNATES TERMINALS AND CONTACTS
DESIGNATES LAMP LOCATION
DESIGNATES TWO POSITION CIRCUIT
DESIGNATES TERMINALS AND CONTACTS
DESIGNATES LAMP LOCATION
DESIGNATES TWO POSITION CIRCUIT
1113
NOTE:
J circuits are available for
all non-locking V-Series
styles. Consult factory for
p/n details.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
10 |
10 LENS
0 - No Actuator Z - No Lens
Clear White Amber Green Red Blue
1 6 8 G M T
2 7 C H N U
3 8 D J P V
4 9 E K R W
5 A F L S Y
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
9 ACTUATOR
0 No Actuator
A, B Contura II
C, D Contura III
Actuator orientation above terminals:
V-Series Contura II & III Sealed Rocker Switches - Ordering Scheme
1
Series
2
Circuit
3
Rating
5
Illumination
6
Lamp
7
Lamp
8
Bracket
9
Actuator
10
Lens
11
Color
12
Legend
13
Legend
Orientation
14
Actuator
Lens Legend
4
Termination
V 1 A B A R 00 00D T 0 B B 0
1 SERIES
V
3 RATING3
1 .4VA @ 28VDC Resistive
B 15A 24V
C 20A 18V
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
F 10A 14V, 6A 14VT (circuit G only)
M .4VA/20A 12V
N .4VA/15A 24V
11 ACTUATOR COLOR1 AND TEXTURE
0 - No Actuator
Black Gray Red White
Soft Surface B G R W
Hard Surface C H S Y
13 LEGEND ORIENTATION
0 No legend (used with codes 11-18 in selection 12)
1 Orientation 1
2 Orientation 2
3 Orientation 3
4 Orientation 4
14 ACTUATOR LENS LEGEND
00 No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
be specied in selection 12; body legend specied in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
1,43,6
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 Body legends not available on Soft surface actuators; White imprinting is standard
on black actuators; Black imprinting is standard on white, red and gray actuators.
Custom colors are available, consult factory.
3 Additional ratings available. See V-Series Switch Accessories page.
4 Contura II available with two square lenses. Consult factory for details.
2 CIRCUIT
Terminal Connections as viewed
( )
- momentary
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3.
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only.
1 - - 4 1 - - 4
2 - - 5 2 - - 5
3 - - 6 3 - - 6
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF
2 B (ON) NONE OFF
3 C ON NONE (OFF)
4 D ON NONE ON
5 F ON NONE (ON)
6 J ON OFF ON
7 K ON OFF (ON)
8 L (ON) OFF (ON)
SPECIAL CIRCUITS
H* 2 & 3 2 & 3, 5 & 4 5 & 4
G* 2 & 3, 5 & 6 2 & 3 OFF
S* 2 & 3, 5 & 6 2 & 3 1 & 2
M* (2 & 3, 5 & 6) 2 & 3 OFF
R* (2 & 3, 5 & 6) 2 & 3 2 & 1
E* 5 & 6 5 & 3 5 & 1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specied in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
4 TERMINATION /BASE STYLE
8 term 10 Term Termination Jumper
1 2 .250 TAB (QC) no barriers No
A B .250 TAB (QC) with barriers No
J K .250 TAB (QC) no barriers Yes T2 to 5
3 5 Solder Lug no barriers No
C D Solder Lug No
5 6 Wire Leads no barriers No
E F Wire Leads No
Note: Codes J & K for circuits H, G & M.
5 ILLUMINATION
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals
S 0 NONE
A 1 1 INDEPENDENT 8 (+) 7 (–)
B 2 1 DOWN 3 (+) 7 (–)
C 3 2 UP 3 (+) 7 (–)
D 4 1 DOWN 3 (+) 7 (–)
2 DOWN 1 (+) 7 (–)
E 5 1 UP 1 (+) 7 (–)
2 UP 3 (+) 7 (–)
F 6 1 INDEPENDENT 8 (+) 7 (–)
2 UP 3 (+) 6 (–)
G 7 1 INDEPENDENT 8 (+) 7 (–)
2 UP 3 (+) 7 (–)
H Z 2 INDEPENDENT 8 (+) 7 (–)
U Y 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 10 (+) 9 (–)
SINGLE POLE SWITCHES ONLY
J 8 1 DOWN 3 (+) 8 (–)
2 INDEPENDENT 6 (+) 7 (–)
K W 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 6 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
L 9 1 DOWN 3 (+) 6 (–)
M R 1 UP 3 (+) 6 (–)
N T 1 DOWN 3 (+) 6 (–)
2 DOWN 1 (+) 4 (–)
P V 1 UP 1 (+) 4 (–)
2 UP 3 (+) 6 (–)
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black White Gray
No Seal B W G
One Seal C Y H
6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
No lamp 0
Neon 1 125VAC 2 250VAC
Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
LED* superbright superbright
Red Amber Green Red
2VDC A L F R
6VDC B M G S
12VDC C N H T
24VDC D P J V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
12 ACTUATOR LENS OR BODY LEGENDS2
11 ON 12 OFF 13 I 14 O
OFF ON O I
15 O O 16 O O 17 O I 18 I O
F N N F
F F
For additional legend options & codes, visit us at www.carlingtech.com.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
| 11
V-Series Contura II & III Locking Sealed Rocker Switches - Ordering Scheme
V
1
Series
2
Circuit
3
Rating
5
Illumination
6
Lock
7
Lamp
8
Bracket
9
Actuator
10
Lens
11
Function
12
Legend
13
Legend
Orientation
4
Termination
1 A S A Z 00D W 0 B E 0
1 SERIES
V
3 RATING4
1 .4VA @ 28VDC Resistive
B 15A 24V
C 20A 18V
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
F 10A 14V, 6A 14VT (circuit G only)
M .4VA/20A 12V
N .4VA/15A 24V
9 HARD SURFACE ACTUATOR1
Black Gray Red White
Contura II A B G H
Contura III C D E F
Actuator orientation above terminals:
11 ACTUATOR LOCK FUNCTION AND COLOR1
Lock Color Up Down Up & Down Center3
Match Actuator A H R 1
Black B J S 2
White C K T 3
Red D L V 4
Safety Orange E M W 5
12 ACTUATOR LENS OR BODY LEGEND2
00 - No Legend
21 22 23 24
OFF ON O I
25 O 26 O 27 O 28 I
F N
F
For additional legend options & codes, visit us at www.carlingtech.com.
13 LEGEND ORIENTATION
0 No legend (used with codes 21-28 in selection 12)
1 Orientation 1
2 Orientation 2
3 Orientation 3
4 Orientation 4 ORIENTATION 2
ORIENTATION OF
ACTUATOR/LENS IN PANEL
ORIENTATION 3
ORIENTATION 1
ORIENTATION 4
AZC45-1
45
AZC45-2
45
6 LOCK
Lock above terminals 1 & 4 end of switch.
W lock
1,43,6
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on white,
red and gray actuators. Custom colors are available, consult factory.
3 Only available with 3 position circuits. Center OFF and special circuits only available
with center position lock function.
4 Additional ratings available. See V-Series Switch Accessories page.
2 CIRCUIT
Terminal Connections as viewed
( )
- momentary
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3.
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only.
1 - - 4 1 - - 4
2 - - 5 2 - - 5
3 - - 6 3 - - 6
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF
2 B (ON) NONE OFF
3 C ON NONE (OFF)
4 D ON NONE ON
5 F ON NONE (ON)
6 J ON OFF ON
7 K ON OFF (ON)
8 L (ON) OFF (ON)
SPECIAL CIRCUITS
H* 2 & 3 2 & 3, 5 & 4 5 & 4
G* 2 & 3, 5 & 6 2 & 3 OFF
S* 2 & 3, 5 & 6 2 & 3 1 & 2
M* (2 & 3, 5 & 6) 2 & 3 OFF
R* (2 & 3, 5 & 6) 2 & 3 2 & 1
E* 5 & 6 5 & 3 5 & 1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specied in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
4 TERMINATION /BASE STYLE
8 term 10 Term Termination Jumper
1 2 .250 TAB (QC) no barriers No
A B .250 TAB (QC) with barriers No
J K .250 TAB (QC) no barriers Yes T2 to 5
3 5 Solder Lug no barriers No
C D Solder Lug No
5 6 Wire Leads no barriers No
E F Wire Leads No
Note: Codes J & K for circuits H, G & M.
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals
S 0 NONE
C 3 2 UP 3 (+) 7 (–)
H Z 2 INDEPENDENT 8 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
M R 1 UP 3 (+) 6 (–)
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black White Gray
No Seal B W G
One Seal C Y H
7 LAMP
Lamp above terminals 3 & 6 end of switch
No lamp 0
Neon 1 125VAC 2 250VAC
Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
LED* superbright superbright
Red Amber Green Red
2VDC A L F R
6VDC B M G S
12VDC C N H T
24VDC D P J V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
10 LENS
Z - No Lens
Clear White Amber Green Red Blue
3 8 D J P V
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
12 |V-Series Contura IV Sealed Rocker Switches - Ordering Scheme
V
1
Series
2
Circuit
3
Rating
5
Illumination
6
Lamp
7
Lamp
8
Bracket
9
Actuator
10
Lens
11
Color
12
Legend
13
Legend
Orientation
14
Actuator
Lens Legend
4
Termination
1 A B E P 00 00D T 0 B C 0
1 SERIES
V
3 RATING4
1 .4VA @ 28VDC Resistive
B 15A 24V
C 20A 18V
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
F 10A 14V, 6A 14VT (circuit G only)
M .4VA/20A 12V
N .4VA/15A 24V
9 ACTUATOR
0 No Actuator
E Contura IV, left orientation
T Contura IV, left orientation, laser etched
F Contura IV, right orientation
R Contura IV, right orientation, laser etched
Actuator orientation above terminals:
11 ACTUATOR COLOR1,5,6
No Actuator 0 Black C Gray H Red S White Y Nickel D Pewter E
13 LEGEND ORIENTATION
0 No legend (used with codes 11-18 in selection 12)
1 Orientation 1
2 Orientation 2
3 Orientation 3
4 Orientation 4
1,4
3,6
ORIENTATION 3
ORIENTATION 4
ORIENTATION 1
ORIENTATION OF
ACTUATOR/LENS IN PANEL
ORIENTATION 2ORIENTATION 2
F8C45-300
E8C45-300
F8C45-100
E8C45-100 E3C70-200
F3C70-200
14 ACTUATOR LENS LEGEND
00 No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
be specied in selection 12; body legend specied in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on white,
red and gray actuators. Custom colors are available, consult factory.
3 Gloss brow is on left side of E actuator and right side of F actuator.
4 Additional ratings available. See V-Series Switch Accessories page.
5 Laser etched rocker only available with lens code Z & actuator colors black,
nickel or pewter.
6 Pewter and nickel colors only available with laser etched actuator.
2 CIRCUIT
Terminal Connections as viewed
( )
- momentary
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3.
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only.
1 - - 4 1 - - 4
2 - - 5 2 - - 5
3 - - 6 3 - - 6
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF
2 B (ON) NONE OFF
3 C ON NONE (OFF)
4 D ON NONE ON
5 F ON NONE (ON)
6 J ON OFF ON
7 K ON OFF (ON)
8 L (ON) OFF (ON)
SPECIAL CIRCUITS
H* 2 & 3 2 & 3, 5 & 4 5 & 4
G* 2 & 3, 5 & 6 2 & 3 OFF
S* 2 & 3, 5 & 6 2 & 3 1 & 2
M* (2 & 3, 5 & 6) 2 & 3 OFF
R* (2 & 3, 5 & 6) 2 & 3 2 & 1
E* 5 & 6 5 & 3 5 & 1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specied in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
4 TERMINATION /BASE STYLE
8 term 10 Term Termination Jumper
1 2 .250 TAB (QC) no barriers No
A B .250 TAB (QC) with barriers No
J K .250 TAB (QC) no barriers Yes T2 to 5
3 5 Solder Lug no barriers No
C D Solder Lug No
5 6 Wire Leads no barriers No
E F Wire Leads No
Note: Codes J & K for circuits H, G & M.
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals
S 0 NONE
A 1 1 INDEPENDENT 8 (+) 7 (–)
B 2 1 DOWN 3 (+) 7 (–)
C 3 2 UP 3 (+) 7 (–)
D 4 1 DOWN 3 (+) 7 (–)
2 DOWN 1 (+) 7 (–)
E 5 1 UP 1 (+) 7 (–)
2 UP 3 (+) 7 (–)
F 6 1 INDEPENDENT 8 (+) 7 (–)
2 UP 3 (+) 6 (–)
G 7 1 INDEPENDENT 8 (+) 7 (–)
2 UP 3 (+) 7 (–)
H Z 2 INDEPENDENT 8 (+) 7 (–)
U Y 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 10 (+) 9 (–)
SINGLE POLE SWITCHES ONLY
J 8 1 DOWN 3 (+) 8 (–)
2 INDEPENDENT 6 (+) 7 (–)
K W 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 6 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
L 9 1 DOWN 3 (+) 6 (–)
M R 1 UP 3 (+) 6 (–)
N T 1 DOWN 3 (+) 6 (–)
2 DOWN 1 (+) 4 (–)
P V 1 UP 1 (+) 4 (–)
2 UP 3 (+) 6 (–)
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black White Gray
No Seal B W G
One Seal C Y H
6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
No lamp 0
Neon 1 125VAC 2 250VAC
Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
LED* superbright superbright
Red Amber Green Red
2VDC A L F R
6VDC B M G S
12VDC C N H T
24VDC D P J V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
10 LENS
0 - No Actuator Z - No Lens
Clear White Amber Green Red Blue
1 6 8 G M T
2 7 C H N U
3 8 D J P V
4 9 E K R W
5 A F L S Y
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
12 ACTUATOR LENS OR BODY LEGENDS2
11 ON 12 OFF 13 I 14 O
OFF ON O I
15 O O 16 O O 17 O I 18 I O
F N N F
F F
For additional legend options & codes, visit us at www.carlingtech.com.
E F
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
| 13
12 ACTUATOR LENS OR BODY LEGENDS2,6
11 ON 12 OFF 13 I 14 O
OFF ON O I
15 O O 16 O O 17 O I 18 I O
F N N F
F F
For additional legend options & codes, visit us at www.carlingtech.com.
V-Series Contura V Sealed Rocker Switches - Ordering Scheme
1
Series
2
Circuit
3
Rating
5
Illumination
6
Lamp
7
Lamp
8
Bracket
9
Actuator
10
Lens
11
Color
12
Legend
13
Legend
Orientation
14
Actuator
Lens Legend
4
Termination
V 1 A B G P 00 00D T 0 B C 0
1 SERIES
V
3 RATING4
1 .4VA @ 28VDC Resistive
B 15A 24V
C 20A 18V
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
F 10A 14V, 6A 14VT (circuit G only)
M .4VA/20A 12V
N .4VA/15A 24V
9 ACTUATOR
0 No Actuator
G Contura V
P Contura V, laser etched
11 ACTUATOR COLOR1,3,3
No Actuator 0 Black C Gray H Red S White Y Nickel D Pewter E
13 LEGEND ORIENTATION
0 No legend (used with codes 11-18 in selection 12)
1 Orientation 1
2 Orientation 2
3 Orientation 3
4 Orientation 4
ORIENTATION 4
ORIENTATION 3
ORIENTATION 1
ORIENTATION OF
ACTUATOR/LENS IN PANEL
ORIENTATION 2
4G13L
MA1MC
4G
MC
MA
4G
3L
4G200
MC
MA
MA3MC
14 ACTUATOR LENS LEGEND
00 No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
be specied in selection 12; body legend specied in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on
white, red and gray actuators. Custom colors are available, consult factory.
3 Laser Etched rocker only available with lens code Z & actuator colors black,
nickel or pewter.
4 Additional ratings available. See V-Series Switch Accessories page.
5 Nickel and Pewter colors only available with laser etched actuator.
6 Consult factory for laser etched lens callout.
2 CIRCUIT
Terminal Connections as viewed
( )
- momentary
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3.
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only.
1 - - 4 1 - - 4
2 - - 5 2 - - 5
3 - - 6 3 - - 6
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF
2 B (ON) NONE OFF
3 C ON NONE (OFF)
4 D ON NONE ON
5 F ON NONE (ON)
6 J ON OFF ON
7 K ON OFF (ON)
8 L (ON) OFF (ON)
SPECIAL CIRCUITS
H* 2 & 3 2 & 3, 5 & 4 5 & 4
G* 2 & 3, 5 & 6 2 & 3 OFF
S* 2 & 3, 5 & 6 2 & 3 1 & 2
M* (2 & 3, 5 & 6) 2 & 3 OFF
R* (2 & 3, 5 & 6) 2 & 3 2 & 1
E* 5 & 6 5 & 3 5 & 1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specied in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
4 TERMINATION /BASE STYLE
8 term 10 Term Termination Jumper
1 2 .250 TAB (QC) no barriers No
A B .250 TAB (QC) with barriers No
J K .250 TAB (QC) no barriers Yes T2 to 5
3 5 Solder Lug no barriers No
C D Solder Lug No
5 6 Wire Leads no barriers No
E F Wire Leads No
Note: Codes J & K for circuits H, G & M.
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals
S 0 NONE
A 1 1 INDEPENDENT 8 (+) 7 (–)
B 2 1 DOWN 3 (+) 7 (–)
C 3 2 UP 3 (+) 7 (–)
D 4 1 DOWN 3 (+) 7 (–)
2 DOWN 1 (+) 7 (–)
E 5 1 UP 1 (+) 7 (–)
2 UP 3 (+) 7 (–)
F 6 1 INDEPENDENT 8 (+) 7 (–)
2 UP 3 (+) 6 (–)
G 7 1 INDEPENDENT 8 (+) 7 (–)
2 UP 3 (+) 7 (–)
H Z 2 INDEPENDENT 8 (+) 7 (–)
U Y 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 10 (+) 9 (–)
SINGLE POLE SWITCHES ONLY
J 8 1 DOWN 3 (+) 8 (–)
2 INDEPENDENT 6 (+) 7 (–)
K W 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 6 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
L 9 1 DOWN 3 (+) 6 (–)
M R 1 UP 3 (+) 6 (–)
N T 1 DOWN 3 (+) 6 (–)
2 DOWN 1 (+) 4 (–)
P V 1 UP 1 (+) 4 (–)
2 UP 3 (+) 6 (–)
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black White Gray
No Seal B W G
One Seal C Y H
6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
No lamp 0
Neon 1 125VAC 2 250VAC
Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
LED* superbright superbright
Red Amber Green Red
2VDC A L F R
6VDC B M G S
12VDC C N H T
24VDC D P J V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
10 Lens
0 - No Actuator Z - No Lens
Clear White Amber Green Red Blue
1 6 8 G M T bar
2 7 C H N U bar/bar
3 8 D J P V oval
4 9 E K R W oval/bar
5 A F L S Y oval/oval
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
14 |V-Series Contura IV & V Locking Sealed Rocker Switches - Ordering Scheme
1
Series
2
Circuit
3
Rating
5
Illumination
6
Lock
7
Lamp
8
Bracket
9
Actuator
10
Lens
11
Function
12
Legend
13
Legend
Orientation
4
Termination
V 1 A S J Z 00D W 0 B E 0
1 SERIES
V
3 RATING4
1 .4VA @ 28VDC Resistive
B 15A 24V
C 20A 18V
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
F 10A 14V, 6A 14VT (circuit G only)
M .4VA/20A 12V
N .4VA/15A 24V
11 ACTUATOR LOCK FUNCTION AND COLOR1
Lock Color Up Down Up & Down Center3
Match Actuator A H R 1
Black B J S 2
White C K T 3
Red D L V 4
Safety Orange E M W 5
Gray F G N 6
13 LEGEND ORIENTATION
0 No legend
1 Orientation 1
2 Orientation 2
3 Orientation 3
4 Orientation 4
ORIENTATION 1
ORIENTATION 2
ORIENTATION 4
ORIENTATION 3
ORIENTATION OF
ACTUATOR/LENS IN PANEL
JHAY3-300
PP
JHAY3-100
P
P
P
NHAY3-100 NHAY3-300
JHAY3-200
NHAY3-200
P
6 LOCK
Lock above terminals 1 & 4 end of switch.
W low prole lock Y6 high prole lock
12 ACTUATOR LENS OR BODY LEGEND2
00 - No Legend
21 22 23 24
OFF ON O I
25 O 26 O 27 O 28 I
F N
F
For additional legend options & codes, visit us at www.carlingtech.com.
9 HARD SURFACE ACTUATOR
CONTURA IV:
Orientation Black Gray Red White
Left J K L M
Right N P R S
CONTURA V:
Orientation Black Gray Red White
U V W Y
1,4
1,4
3,6
3,6
Actuator orientation above terminals:
Actuator orientation above terminals:
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on white,
red and gray actuators. Custom colors are available, consult factory.
3 Only available with 3 position circuits. Center OFF and special circuits only available
with center position lock function.
4 Additional ratings available. See V-Series Switch Accessories page.
5 Located at T3-6 end of switch.
6 Contura V style only.
2 CIRCUIT3
Terminal Connections as viewed
( )
- momentary
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3.
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only.
1 - - 4 1 - - 4
2 - - 5 2 - - 5
3 - - 6 3 - - 6
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF
4 D ON NONE ON
6 J ON OFF ON
7 K ON OFF (ON)
8 L (ON) OFF (ON)
9 N OFF NONE ON
4 TERMINATION /BASE STYLE
8 term 10 Term Termination Jumper
1 2 .250 TAB (QC) no barriers No
A B .250 TAB (QC) with barriers No
J K .250 TAB (QC) no barriers Yes T2 to 5
3 5 Solder Lug no barriers No
C D Solder Lug No
5 6 Wire Leads no barriers No
E F Wire Leads No
Note: Codes J & K for circuits H, G & M.
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals
S 0 NONE
C 3 2 UP 3 (+) 7 (–)
H Z 2 INDEPENDENT 8 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
M R 1 UP 3 (+) 6 (–)
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black White Gray
No Seal B W G
One Seal C Y H
7 LAMP
Lamp above terminals 3 & 6 end of switch
No lamp 0
Neon 1 125VAC 2 250VAC
Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
LED* superbright superbright
Red Amber Green Red
2VDC A L F R
6VDC B M G S
12VDC C N H T
24VDC D P J V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
10 LENS5
Z - No Lens
Clear White Amber Green Red Blue
A B C D E F bar lens
G H J K L M oval lens
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
| 15
V-Series Contura VI WAVE Sealed Rocker Switches - Ordering Scheme
15 LEGEND ORIENTATION
0 No legend (used with codes 11-18 in selection 12)
1 Orientation 1
2 Orientation 2
3 Orientation 3
4 Orientation 4
1
Series
2
Circuit
3
Rating
5
Illumination
6
Lamp
7
Lamp
8
Bracket
9
Actuator
10
Lens
11
Lens
12
Color
13
Insert
Color
15
Legend
Orientation
14
Actuator
Lens
16
Actuator
Lens Legend
4
Termination
V 1 B G H A AC 00D N T B 7 C B 1
1 SERIES
V
3 RATING3
1 .4VA @ 28VDC Resistive
B 15A 24V
C 20A 18V
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
F 10A 14V, 6A 14VT (circuit G only)
M .4VA/20A 12V
N .4VA/15A 24V
12 ACTUATOR COLOR
C Black H Gray S Red Y White
13 INSERT COLOR
B Black
C Bright Chrome Plated
D Satin Chrome Painted
N Bright Nickel Plated
S Satin Chrome Plated
T Satin Nickel Plated
W White
16 ACTUATOR LENS LEGEND
00 No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
be specied in selection 12; body legend specied in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
1
2
4
Orientation
Orientation
VTHA7CN-3M100
VTLLFHC-A813H
VTHAACN-MC1MC VTHWZCB-45146
VTLSZSC-70100
VTLDECC-001MG
9 ACTUATOR
0 No Actuator H High Insert L Low Insert
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators. Black imprinting is standard on white,
red and gray actuators. Custom colors are available, consult factory.
3 Additional ratings available. See V-Series Switch Accessories page.
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black White Gray
No Seal B W G
One Seal C Y H
7 LAMP
Lamp above terminals 3 & 6 end of switch
No lamp 0
Neon 1 125VAC 2 250VAC
Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
LED* superbright superbright
Red Amber Green Red
2VDC A L F R
6VDC B M G S
12VDC C N H T
24VDC D P J V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
2 CIRCUIT
Terminal Connections as viewed
( )
- momentary
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3.
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only.
1 - - 4 1 - - 4
2 - - 5 2 - - 5
3 - - 6 3 - - 6
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF
2 B (ON) NONE OFF
3 C ON NONE (OFF)
4 D ON NONE ON
5 F ON NONE (ON)
6 J ON OFF ON
7 K ON OFF (ON)
8 L (ON) OFF (ON)
SPECIAL CIRCUITS
H* 2 & 3 2 & 3, 5 & 4 5 & 4
G* 2 & 3, 5 & 6 2 & 3 OFF
S* 2 & 3, 5 & 6 2 & 3 1 & 2
M* (2 & 3, 5 & 6) 2 & 3 OFF
R* (2 & 3, 5 & 6) 2 & 3 2 & 1
E* 5 & 6 5 & 3 5 & 1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specied in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
4 TERMINATION /BASE STYLE
8 term 10 Term Termination Jumper
1 2 .250 TAB (QC) no barriers No
A B .250 TAB (QC) with barriers No
J K .250 TAB (QC) no barriers Yes T2 to 5
3 5 Solder Lug no barriers No
C D Solder Lug No
5 6 Wire Leads no barriers No
E F Wire Leads No
Note: Codes J & K for circuits H, G & M.
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals
S 0 NONE
A 1 1 INDEPENDENT 8 (+) 7 (–)
B 2 1 DOWN 3 (+) 7 (–)
C 3 2 UP 3 (+) 7 (–)
D 4 1 DOWN 3 (+) 7 (–)
2 DOWN 1 (+) 7 (–)
E 5 1 UP 1 (+) 7 (–)
2 UP 3 (+) 7 (–)
F 6 1 INDEPENDENT 8 (+) 7 (–)
2 UP 3 (+) 6 (–)
G 7 1 INDEPENDENT 8 (+) 7 (–)
2 UP 3 (+) 7 (–)
H Z 2 INDEPENDENT 8 (+) 7 (–)
U Y 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 10 (+) 9 (–)
SINGLE POLE SWITCHES ONLY
J 8 1 DOWN 3 (+) 8 (–)
2 INDEPENDENT 6 (+) 7 (–)
K W 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 6 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
L 9 1 DOWN 3 (+) 6 (–)
M R 1 UP 3 (+) 6 (–)
N T 1 DOWN 3 (+) 6 (–)
2 DOWN 1 (+) 4 (–)
P V 1 UP 1 (+) 4 (–)
2 UP 3 (+) 6 (–)
10,11 LENS4
0 - No Actuator Z - No Lens
Clear White Amber Green Red Blue
7 C H N U Bar Lens Translucent
3 D J P V Bar Lens Transparent
4 E K R W Oval Lens Transparent
A F L S Y Oval Lens Translucent
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
14 ACTUATOR LENS OR BODY LEGENDS2
00 - No Legend this location/No actuator
11 ON 12 OFF 13 I 14 O
OFF ON O I
15 O O 16 O O 17 O I 18 I O
F N N F
F F
For additional legend options & codes, visit us at www.carlingtech.com.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
16 |V-Series Contura VII Sealed Rocker Switches - Ordering Scheme
1
Series
2
Circuit
3
Rating
5
Illumination
6
Lamp
7
Lamp
8
Bracket
9
Actuator
10
Lens
11
Color
12
Legend
13
Legend
Orientation
14
Actuator
Lens Legend
4
Termination
V 1 A B Z R 00 00D T 0 B C 0
1 SERIES
V
3 RATING4
1 .4VA @ 28VDC Resistive
B 15A 24V
C 20A 18V
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
F 10A 14V, 6A 14VT (circuit G only)
M .4VA/20A 12V
N .4VA/15A 24V
9 ACTUATOR
0 No Actuator
Z Contura VII
13 LEGEND ORIENTATION
0 No legend (used with codes 11-18 in selection 12)
1 Orientation 1
2 Orientation 2
3 Orientation 3
4 Orientation 4
ORIENTATION 3
ORIENTATION 2
ORIENTATION 1
ORIENTATION 4
14 ACTUATOR LENS LEGEND
00 No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
be specied in selection 12; body legend specied in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
ACTUATOR
ORENTATION
ABOVE TERMINALS
STANDARD
3,6 1,4
10 LENS
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
0 - No Actuator Z - No Lens
White Amber Green Red Blue Lens style & location
6 B G M T
7 C H N U
8 D J P V
9 E K R W
A F L S Y
1 2 3 4 5
11 ACTUATOR COLOR/THUMB PRINT COLOR1
O N/A - No Actuator C Black/Black
H Grey/Black S Red/Black
Y White/Black
ORIENTATION 3
ORIENTATION 2
ORIENTATION 1
ORIENTATION 4
ORIENTATION 3
ORIENTATION 2
ORIENTATION 1
ORIENTATION 4
46
3AA-246
AA
3AA-146
46
AA
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators. Black imprinting is standard on white,
red and gray actuators. Custom colors are available, consult factory.
3 Additional ratings available. See V-Series Switch Accessories page.
4 Legends available for lighted oval lens version only
2 CIRCUIT
Terminal Connections as viewed
( )
- momentary
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3.
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only.
1 - - 4 1 - - 4
2 - - 5 2 - - 5
3 - - 6 3 - - 6
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF
2 B (ON) NONE OFF
3 C ON NONE (OFF)
4 D ON NONE ON
5 F ON NONE (ON)
6 J ON OFF ON
7 K ON OFF (ON)
8 L (ON) OFF (ON)
SPECIAL CIRCUITS
H* 2 & 3 2 & 3, 5 & 4 5 & 4
G* 2 & 3, 5 & 6 2 & 3 OFF
S* 2 & 3, 5 & 6 2 & 3 1 & 2
M* (2 & 3, 5 & 6) 2 & 3 OFF
R* (2 & 3, 5 & 6) 2 & 3 2 & 1
E* 5 & 6 5 & 3 5 & 1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specied in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
4 TERMINATION /BASE STYLE
8 term 10 Term Termination Jumper
1 2 .250 TAB (QC) no barriers No
A B .250 TAB (QC) with barriers No
J K .250 TAB (QC) no barriers Yes T2 to 5
3 5 Solder Lug no barriers No
C D Solder Lug No
5 6 Wire Leads no barriers No
E F Wire Leads No
Note: Codes J & K for circuits H, G & M.
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals
S 0 NONE
A 1 1 INDEPENDENT 8 (+) 7 (–)
B 2 1 DOWN 3 (+) 7 (–)
C 3 2 UP 3 (+) 7 (–)
D 4 1 DOWN 3 (+) 7 (–)
2 DOWN 1 (+) 7 (–)
E 5 1 UP 1 (+) 7 (–)
2 UP 3 (+) 7 (–)
F 6 1 INDEPENDENT 8 (+) 7 (–)
2 UP 3 (+) 6 (–)
G 7 1 INDEPENDENT 8 (+) 7 (–)
2 UP 3 (+) 7 (–)
H Z 2 INDEPENDENT 8 (+) 7 (–)
U Y 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 10 (+) 9 (–)
SINGLE POLE SWITCHES ONLY
J 8 1 DOWN 3 (+) 8 (–)
2 INDEPENDENT 6 (+) 7 (–)
K W 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 6 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
L 9 1 DOWN 3 (+) 6 (–)
M R 1 UP 3 (+) 6 (–)
N T 1 DOWN 3 (+) 6 (–)
2 DOWN 1 (+) 4 (–)
P V 1 UP 1 (+) 4 (–)
2 UP 3 (+) 6 (–)
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black White Gray
No Seal B W G
One Seal C Y H
6,7 LAMP (same coding for both selections)
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
No lamp 0
Neon 1 125VAC 2 250VAC
Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
LED* superbright superbright
Red Amber Green Red
2VDC A L F R
6VDC B M G S
12VDC C N H T
24VDC D P J V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
14 ACTUATOR LENS OR BODY LEGENDS2
11 ON 12 OFF 13 I 14 O
OFF ON O I
15 O O 16 O O 17 O I 18 I O
F N N F
F F
For additional legend options & codes, visit us at www.carlingtech.com.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
| 17
V-Series Contura X, XI & XII Sealed Rocker Switches - Ordering Scheme
1
Series
2
Circuit
3
Rating
5
Illumination
6
Lamp
7
Lamp
8
Bracket
9
Actuator
10
Lens
11
Lens
12
Legend
13
Legend
Orientation
14
Actuator
Lens Legend
4
Termination
V 1 A B 6 P 00 00D 6 0 1 Z 0
1 SERIES
V
3 RATING4
1 .4VA @ 28VDC Resistive
B 15A 24V
C 20A 18V
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
F 10A 14V, 6A 14VT (circuit G only)
M .4VA/20A 12V
N .4VA/15A 24V
14 ACTUATOR LENS LEGEND
00 No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
be specied in selection 12; body legend specied in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
9 ACTUATOR
No Actuator 0
Black Gray White Red
Contura X 1 2 3 4
Contura XI 6 7 8 9
Contura XII J K N M
Actuator orientation above terminals: 1,4
3,6
13 LEGEND ORIENTATION3
0 No legend (used with codes 11-18 in selection 12)
1 Orientation 1
2 Orientation 2
3 Orientation 3
4 Orientation 4
ORIENTATION 1
ORIENTATION 2
ORIENTATION 4
ORIENTATION 3
ORIENTATION OF
ACTUATOR/LENS IN PANEL
70
MCMA
6FFMA-4MC
6FZ70-100
6ZZ3G-100
MC
3G
A7
G3
MA
6ZZ3G-1A7 6FFMA-3MC
10 LENS - ABOVE LAMP #1 TERMINALS1,4
11 LENS - ABOVE LAMP #2 TERMINALS3,6
0 - No Actuator Z - No Lens
Clear White Amber Green Red Blue Lens Style
3 8 D J P V Bar
4 9 E K R W One piece Square
5 A F L S Y Two piece Square*
(w/ clear top protective lens)
2 7 C H N U Two piece Square*
(w/ smoke top protective lens)
1 6 B G M T Two piece Square*
(w/ white top protective lens)
* All bottom lenses are molded of opaque material. Consult factory for other lens colors.
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
12 ACTUATOR LENS OR BODY LEGEND2
00 - No Legend this location/No actuator
11 ON 12 OFF 13 I 14 O
OFF ON O I
15 O O 16 O O 17 O I 18 I O
F N N F
F F
21 22 23 24
OFF ON O I
25 O 26 O 27 O 28 I
F N
F
For additional legend options & codes, visit us at www.carlingtech.com.
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on white,
red & gray actuators. Custom colors are available, consult factory.
3 With 2 square lenses, use sel. 12 for lens above lamp 1, & selection 14 for lens above lamp 2.
4 Additional ratings available. See V-Series Switch Accessories page.
5 Not available with Contura XI rockers.
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals
S 0 NONE
A 1 1 INDEPENDENT 8 (+) 7 (–)
B 2 1 DOWN 3 (+) 7 (–)
C 3 2 UP 3 (+) 7 (–)
D 4 1 DOWN 3 (+) 7 (–)
2 DOWN 1 (+) 7 (–)
E 5 1 UP 1 (+) 7 (–)
2 UP 3 (+) 7 (–)
F 6 1 INDEPENDENT 8 (+) 7 (–)
2 UP 3 (+) 6 (–)
G 7 1 INDEPENDENT 8 (+) 7 (–)
2 UP 3 (+) 7 (–)
H Z 2 INDEPENDENT 8 (+) 7 (–)
U Y 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 10 (+) 9 (–)
SINGLE POLE SWITCHES ONLY
J 8 1 DOWN 3 (+) 8 (–)
2 INDEPENDENT 6 (+) 7 (–)
K W 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 6 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
L 9 1 DOWN 3 (+) 6 (–)
M R 1 UP 3 (+) 6 (–)
N T 1 DOWN 3 (+) 6 (–)
2 DOWN 1 (+) 4 (–)
P V 1 UP 1 (+) 4 (–)
2 UP 3 (+) 6 (–)
8 BRACKET COLOR1, PANEL SEAL (EXTERNAL FOAM GASKET)
X & XI w/Flush Bracket X, XI, XII w/Raised Bracket
# of gaskets 0 1 2 0 1
Black B C D 1 4
White W Y Z 2 5
Gray G H J 3 6
6,7 LAMP (same coding for both selections)
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
No lamp 0
Neon 1 125VAC 2 250VAC
Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
LED* superbright superbright
Red Amber Green Red
2VDC A L F R
6VDC B M G S
12VDC C N H T
24VDC D P J V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
4 TERMINATION /BASE STYLE
8 term 10 Term Termination Jumper
1 2 .250 TAB (QC) no barriers No
A B .250 TAB (QC) with barriers No
J K .250 TAB (QC) no barriers Yes T2 to 5
3 5 Solder Lug no barriers No
C D Solder Lug No
5 6 Wire Leads no barriers No
E F Wire Leads No
Note: Codes J & K for circuits H, G & M.
2 CIRCUIT
Terminal Connections as viewed
( )
- momentary
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3.
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only.
1 - - 4 1 - - 4
2 - - 5 2 - - 5
3 - - 6 3 - - 6
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF
2 B (ON) NONE OFF
3 C ON NONE (OFF)
4 D ON NONE ON
5 F ON NONE (ON)
6 J ON OFF ON
7 K ON OFF (ON)
8 L (ON) OFF (ON)
SPECIAL CIRCUITS
H* 2 & 3 2 & 3, 5 & 4 5 & 4
G* 2 & 3, 5 & 6 2 & 3 OFF
S* 2 & 3, 5 & 6 2 & 3 1 & 2
M* (2 & 3, 5 & 6) 2 & 3 OFF
R* (2 & 3, 5 & 6) 2 & 3 2 & 1
E* 5 & 6 5 & 3 5 & 1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specied in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
18 |V-Series Contura X Locking Sealed Rocker Switches - Ordering Scheme
1
Series
2
Circuit
3
Rating
5
Illumination
6
Lock
7
Lamp
8
Bracket
9
Actuator
10
Lens
11
Function
12
Legend
13
Legend
Orientation
4
Termination
V 1 A S 1 P 00D W 0 1 B 0
1 SERIES
V
3 RATING4
1 .4VA @ 28VDC Resistive
B 15A 24V
C 20A 18V
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
F 10A 14V, 6A 14VT (circuit G only)
M .4VA/20A 12V
N .4VA/15A 24V
11 ACTUATOR LOCK FUNCTION AND COLOR3
Lock Color Up Down Up & Down
Match Actuator A H R
Black B J S
White C K T
Red D L V
Gray E M W
Safety Orange F N Y
13 LEGEND ORIENTATION3
0 No legend (used with codes 11-18 in selection 12)
1 Orientation 1
2 Orientation 2
3 Orientation 3
4 Orientation 4
Orientation 1
Orientation
2
Orientation 3
Orientation
4
13DMC-1
1PM4F-1
18K45-2
MC
4F
45
6 LOCK
Lock above terminals 1 & 4 end of switch.
W lock
12 ACTUATOR LENS OR BODY LEGEND2
00 - No Legend
21 22 23 24
OFF ON O I
25 O 26 O 27 O 28 I
F N
F
For additional legend options & codes, visit us at www.carlingtech.com.
9 HARD SURFACE ACTUATOR
Contura X Black
1
1,43,6Actuator orientation above terminals:
Grey
2
Red
3
White
4
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on white,
red and gray actuators; Custom colors are available, consult factory.
3 Located over T1-4 end of switch.
4 Additional ratings available. See V-Series Switch Accessories page.
5 Located over T3-6 end of switch.
2 CIRCUIT
Terminal Connections as viewed
( )
- momentary
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3.
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only.
1 - - 4 1 - - 4
2 - - 5 2 - - 5
3 - - 6 3 - - 6
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF
4 D ON NONE ON
6 J ON OFF ON
9 N OFF NONE ON
SPECIAL CIRCUITS
H* 2 & 3 2 & 3, 5 & 4 5 & 4
G* 2 & 3, 5 & 6 2 & 3 OFF
S* 2 & 3, 5 & 6 2 & 3 1 & 2
E* 5 & 6 5 & 3 5 & 1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specied in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
4 TERMINATION /BASE STYLE
8 term 10 Term Termination Jumper
1 2 .250 TAB (QC) no barriers No
A B .250 TAB (QC) with barriers No
J K .250 TAB (QC) no barriers Yes T2 to 5
3 5 Solder Lug no barriers No
C D Solder Lug No
5 6 Wire Leads no barriers No
E F Wire Leads No
Note: Codes J & K for circuits H, G & M.
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals
S 0 NONE
C 3 2 UP 3 (+) 7 (–)
H Z 2 INDEPENDENT 8 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
M R 1 UP 3 (+) 6 (–)
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black White Gray
No Gasket 1 2 3
One Gasket 4 5 6
6,7 LAMP (same coding for both selections)
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
No lamp 0
Neon 1 125VAC 2 250VAC
Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
LED* superbright superbright
Red Amber Green Red
2VDC A L F R
6VDC B M G S
12VDC C N H T
24VDC D P J V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
10 LENS - ABOVE LAMP #2 TERMINALS5
Z - No Lens
Clear White Amber Green Red Blue Lens Style
3 8 D J P V Bar
4 9 E K R W One piece Square
5 A F L S Y Two piece Square*
(w/ clear top protective lens)
2 7 C H N U Two piece Square*
(w/ smoke top protective lens)
1 6 B G M T Two piece Square*
(w/ white top protective lens)
* All bottom lenses are molded of opaque material. Consult factory for other lens colors.
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
| 19
V-Series Contura XIV Sealed Rocker Switches - Ordering Scheme
1
Series
2
Circuit
3
Rating
5
Illumination
6
Lamp
7
Lamp
8
Bracket
9
Actuator
10
Lens
11
Actuator
Color
12
Legend
14
Actuator,
Lens Legends
13
Legend
Orientation
4
Termination
V 1 B B FA P AB 00D C 0 B C 1
1 SERIES
V
11 ACTUATOR COLOR1
O N/A - No Actuator
C Black
S Red
Y White
8 BRACKET COLOR & PANEL SEAL
Color No Gasket 1 Gasket 2 Gasket
Black B C D
Gray G H J
White W Y Z
9 ACTUATOR STYLE
0 No Actuator - Furnished separately
FA Contura XIV
FB Contura XIV - Laser Etched
4 TERMINATION / BASE STYLE
8 term 10 Term Termination Jumper
1 2 .250 TAB (QC) no barriers No
A B .250 TAB (QC) with barriers No
J K .250 TAB (QC) no barriers Yes T2 to 5
3 4 Solder Lug no barriers No
C D Solder Lug No
5 6 Wire Leads no barriers No
E F Wire Leads No
Note: Codes J & K for circuits H, G & M.
6 & 7 LAMP
No lamp 0
Neon 1 125VAC 2 250VAC
Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
LED* superbright superbright
Red Amber Green Red
2VDC A L F R
6VDC B M G S
12VDC C N H T
24VDC D P J V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
2 CIRCUIT
Terminal Connections as viewed
( )
- momentary
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3.
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only.
1 - - 4 1 - - 4
2 - - 5 2 - - 5
3 - - 6 3 - - 6
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF
2 B (ON) NONE OFF
3 C ON NONE (OFF)
4 D ON NONE ON
5 F ON NONE (ON)
6 J ON OFF ON
7 K ON OFF (ON)
8 L (ON) OFF (ON)
SPECIAL CIRCUITS
H* 2 & 3 2 & 3, 5 & 4 5 & 4
G* 2 & 3, 5 & 6 2 & 3 OFF
M* (2 & 3, 5 & 6) 2 & 3 OFF
R* (2 & 3, 5 & 6) 2 & 3 2 & 1
E* 5 & 6 5 & 3 5 & 1
S* 2 & 3, 5 & 6 2 & 3 1 & 2
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specied in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
5 ILLUMINATION
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Lamps Illumination Type Lamp wired to Terminals
S NONE
A 1 INDEPENDENT 8 (+) 7 (–)
B 1 DOWN 3 (+) 7 (–)
C 2 UP 3 (+) 7 (–)
D 1 DOWN 3 (+) 7 (–)
2 DOWN 1 (+) 7 (–)
E 1 UP 1 (+) 7 (–)
2 UP 3 (+) 7 (–)
F 1 INDEPENDENT 8 (+) 7 (–)
2 UP 3 (+) 6 (–)
G 1 INDEPENDENT 8 (+) 7 (–)
2 UP 3 (+) 7 (–)
H 2 INDEPENDENT 8 (+) 7 (–)
SINGLE POLE SWITCHES ONLY
J 1 DOWN 3 (+) 8 (–)
2 INDEPENDENT 6 (+) 7 (–)
K 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 6 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
L 1 DOWN 3 (+) 6 (–)
M 1 UP 3 (+) 6 (–)
N 1 DOWN 3 (+) 6 (–)
2 DOWN 1 (+) 4 (–)
P 1 UP 1 (+) 4 (–)
2 UP 3 (+) 6 (–)
U 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 10 (+) 9 (–)
10 LENS COLOR / STYLE
0 - No Actuator Z - No Lens
Clear White Amber Green Red Blue
1 6 B G M T
2 7 C H N U
3 8 D J P V
4 9 E K R W
5 A F L S Y PAD Printed
5 A N/A N/A N/A N/A Laser-Etched
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
3 RATING3
1 .4VA @ 28VDC Resistive
B 15A 24V
C 20A 18V
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
F 10A 14V, 6A 14VT (circuit G only)
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on white,
red and gray actuators.
3 Additional ratings available. See V-Series Switch Accessories page.
12 ACTUATOR LENS or BODY LEGEND2
00 - No Legend this location/No actuator
11 ON 12 OFF 13 I 14 O
OFF ON O I
15 O O 16 O O 17 O I 18 I O
F N N F
F F
13 LEGEND ORIENTATION
0 No legend
1 Orientation 1
2 Orientation 2
3 Orientation 3
4 Orientation 4
2431
14 ACTUATOR / LENS LEGEND
00 No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
be specied in selection 12; body legend specied in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
20 |V-Series Contura Sealed Rocker Switch Actuators Separately
1
Actuator Separately
1
Lens Separately
1
Actuator
2
Actuator
Style/Color
2
Color
2
Style &
Color
3
Lens
Opening
3
Lens
Opening
5
Legend
Orientation
5
Legend
7
Legend
4
Actuator
Legend
4
Lens
Opening
6
Legend
Orientation
1 piece lens/bar lens are positioned the same as bottom lens for assembly,
minus the top lens. Lenses snap in from bottom.
2 COLOR
1 Clear 2 Smoke 3 White
Reduce inventory levels and cost by stocking actuators and base switches separately.
Contura II, III, IV, V, VI, VII, X, XI, XII, XIV Base switches separately: specify V with code selections 2-8 in the ordering schemes.
Contura II, III, IV, V Actuator only: VV with code A or C for selection 9, & with selections 10-14 in the ordering schemes.
Contura VI Actuator with lenses and inserts only: VV with code selections 9-16
Contura II, III, IV, V, VII Actuator only: VV with code A, C, E, G, P or Z for selection 9 & with selections 10-14 in the ordering schemes.
Contura X, XI, XII, XIV actuators with lenses separately: VV with code selections 9-14 in the ordering schemes.
Panel Seal: VPS
Contura X & XI actuators without lenses separately:
Contura X, XI & XII top piece of 2-piece lens separately:
Contura X, XI & XII actuator lens assembly:
Contura XII actuators without lenses separately:
VVR
VVT
VVP6
1
J 00 21 0011 1 Z 1
1 CONTURA X & XI ACTUATOR SEPARATELY
VVP
1 TOP OF LENS SEPARATELY
VVT
1 CONTURA XII ACTUATOR SEPARATELY
VVP
3,4 LENS OPENING FOR
6 LEGEND ORIENTATION3
0 No legend
1 Orientation 1
2 Orientation 2
2 ACTUATOR STYLE & COLOR
Contura X
Contura XI
Black
1
6
Gray
2
7
White
3
8
Red
4
9
3 LENS OPENING FOR1
1 One bar lens
2 One bar lenses
3 One square lens
4 two square lens
5 square lens on top/
bar lens on bottom
(Contura X only)
4 ACTUATOR LENS OR BODY LEGEND
00 - No Legend this location
11 ON 12 OFF 13 I 14 O
OFF ON O I
15 O O 16 O O 17 O I 18 I O
F N N F
F F
For additional legend options & codes, visit us at www.carlingtech.com.
5, 7 LENS OR BODY LEGEND2
00 - No Legend 21 22 23 24
OFF ON O I
25 O 26 O 27 O 28 I
F N
F
For additional legend options & codes, visit us at www.carlingtech.com.
4 LENS OR BODY LEGEND2
00 - No Legend 21 22 23 24
OFF ON O I
25 O 26 O 27 O 28 I
F N
F
For additional legend options & codes, visit us at www.carlingtech.com.
5 LEGEND ORIENTATION1
0 No legend
1 Orientation 1
2 Orientation 2
3 Orientation 3
4 Orientation 4
ORIENTATION 1
ORIENTATION 2ORIENTATION 4
ORIENTATION 3
ORIENTATION OF
ACTUATOR/LENS IN PANEL
actuator stem top lens
bottom lens }two piece
lens assembly
posts mount toward actuator stem
2 ACTUATOR STYLE & COLOR
J Black K Gray N White M Red
Z No lens 1 Bar lens 2 Square lens
1
Lens Separately
2
Lens
Style
3
Lens
Color
5
Legend
Orientation
4
Legend
Contura X, XI & XII actuator lens assembly separately:
VVL 2 00 01
1 CONTURA X, XI & XII LENS SEPARATELY
VVL
2 LENS STYLE3
1 Bar lens 2 One Piece Square lens 3 Bottom of Two-Piece Square lens5
3 TRANSLUCENT LENS COLOR
1 Clear 2 White 3 Amber 4 Green4 5 Red 6 Blue4
5 LEGEND ORIENTATION3
0 No legend
1 Orientation 1
2 Orientation 2
3 Orientation 3
4 Orientation 4
ORIENTATION 1
ORIENTATION 2
ORIENTATION 4
ORIENTATION 3
ORIENTATION OF
ACTUATOR/LENS IN PANEL
ORIENTATION 1
ORIENTATION 2
ORIENTATION OF
ACTUATOR/LENS IN PANEL
Notes:
1 If actuator lens opening for 2 bar or 2 square lenses, legend orientation 0,1, or 2
must be chosen.
2 Center of actuator marking not available for Contura XII.
3 Legend is not available for bar style lens.
4 Not recommended with neon lamps.
5 Must also order top piece of 2 piece square lens separately.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
| 21
V-Series Contura Sealed Rocker Switch Accessories
6
AMP, PACKARD 58
7
PACKARD 630
A
B
54
MARKING DETAIL
REAR VIEW
.770[19.56]
MM
(REF)
3.012
(2)1.0-2.0(2)16-14
.950[24.13]
SYMBOL
TANG
ORIEN-
TATION
.5-.820-18
1.0-2.016-14
AWG
B
WIRE
RANGE
.5-.8
.35-.5
20-18
20-22
.8-2
1.3-316-12
(2)22-18
16-14
18-14
A
.3-.9
B
1.0-2.0
12 3.0
(2).5-.8
22-18
(2) 1.3(2) 16
.820[20.83]
.820[20.83]
60295-1
42100-1
60253-1
12015832
PACKARD
METRI-PACK
630 SERIES
AMP
250 SERIES
FASTIN-FASTON
PACKARD
58 SERIES
02965471
COMPANY
SERIES
02965580
PART NO
02965469
02965470
PLAIN
BRASS
AMP
95 AMP, PACKARD 58
VB1-01
CONTURA X BOOT
8
MARKING DETAIL
REAR VIEW
VC2
4
PACKARD 630
13 2
7 6
B
A
1.466[37.24]
VC2
VC1
6
AMP
82 1
VC2
CONNECTOR HOUSING
(For AMP terminals only)
39
A
B
10
MARKING DETAIL
FRONT VIEW
1.266[32.16]
.757[19.23]
.900 [22.86]
TOP
HOLD FLUSH ON BRACKET AND PUSH
IN
TOP
INSERT POINTS UNDER
ACTUATOR
VRT
ACTUATOR REMOVAL
TOOL
(For flush bracket)
1.050[26.67]
AMP, PACKARD 58
71 8
VC1
CONNECTOR HOUSING
3
PACKARD 630
B
4
VC1
A
MARKING DETAIL
FRONT VIEW
10 2
1.266[32.16]
06288318
12084590
12015870
12052224
12015869
60253-2
TIN
PLATED
BRASS
10 5.0
TANG SYMBOL =
12052222
12020035
NOTE: Consult Delphi Packard and/or Amp on actual part numbers and availability.
AMP is a registered trademark of AMP Inc. Harrisburg, PA
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio
60295-2
42100-2
Q.C. SELECTION GUIDE
12010601
2.000[50.80]
3.99 [101.35]
1.466[37.24]
AMP, PACKARD 58
PACKARD 630
MARKING DETAIL
REAR VIEW
5
SHOWS ORIENTATION OF TANG IN SLOT
VCH
CONNECTOR HOUSING
MARKING DETAIL
FRONT VIEW
.920[23.37] .920[23.37] 1.170[29.72]
1.250[31.75]
2
6
AMP, PACKARD 58
7
PACKARD 630
A
B
54
MARKING DETAIL
REAR VIEW
.770[19.56]
MM
(REF)
3.012
(2)1.0-2.0(2)16-14
.950[24.13]
SYMBOL
TANG
ORIEN-
TATION
.5-.820-18
1.0-2.016-14
AWG
B
WIRE
RANGE
.5-.8
.35-.5
20-18
20-22
.8-2
1.3-316-12
(2)22-18
16-14
18-14
A
.3-.9
B
1.0-2.0
12 3.0
(2).5-.8
22-18
(2) 1.3(2) 16
.820[20.83]
.820[20.83]
60295-1
42100-1
60253-1
12015832
PACKARD
METRI-PACK
630 SERIES
AMP
250 SERIES
FASTIN-FASTON
PACKARD
58 SERIES
02965471
COMPANY
SERIES
02965580
PART NO
02965469
02965470
PLAIN
BRASS
AMP
95 AMP, PACKARD 58
VB1-01
CONTURA X BOOT
8
MARKING DETAIL
REAR VIEW
VC2
4
PACKARD 630
13 2
7 6
B
A
1.466[37.24]
VC2
VC1
6
AMP
82 1
VC2
CONNECTOR HOUSING
(For AMP terminals only)
39
A
B
10
MARKING DETAIL
FRONT VIEW
1.266[32.16]
.757[19.23]
.900 [22.86]
TOP
HOLD FLUSH ON BRACKET AND PUSH
IN
TOP
INSERT POINTS UNDER
ACTUATOR
VRT
ACTUATOR REMOVAL
TOOL
(For flush bracket)
1.050[26.67]
AMP, PACKARD 58
71 8
VC1
CONNECTOR HOUSING
3
PACKARD 630
B
4
VC1
A
MARKING DETAIL
FRONT VIEW
10 2
1.266[32.16]
06288318
12084590
12015870
12052224
12015869
60253-2
TIN
PLATED
BRASS
10 5.0
TANG SYMBOL =
12052222
12020035
NOTE: Consult Delphi Packard and/or Amp on actual part numbers and availability.
AMP is a registered trademark of AMP Inc. Harrisburg, PA
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio
60295-2
42100-2
Q.C. SELECTION GUIDE
12010601
2.000[50.80]
3.99 [101.35]
1.466[37.24]
AMP, PACKARD 58
PACKARD 630
MARKING DETAIL
REAR VIEW
5
SHOWS ORIENTATION OF TANG IN SLOT
VCH
CONNECTOR HOUSING
MARKING DETAIL
FRONT VIEW
.920[23.37] .920[23.37] 1.170[29.72]
1.250[31.75]
2
6
AMP, PACKARD 58
7
PACKARD 630
A
B
54
MARKING DETAIL
REAR VIEW
.770[19.56]
MM
(REF)
3.012
(2)1.0-2.0(2)16-14
.950[24.13]
SYMBOL
TANG
ORIEN-
TATION
.5-.820-18
1.0-2.016-14
AWG
B
WIRE
RANGE
.5-.8
.35-.5
20-18
20-22
.8-2
1.3-316-12
(2)22-18
16-14
18-14
A
.3-.9
B
1.0-2.0
12 3.0
(2).5-.8
22-18
(2) 1.3(2) 16
.820[20.83]
.820[20.83]
60295-1
42100-1
60253-1
12015832
PACKARD
METRI-PACK
630 SERIES
AMP
250 SERIES
FASTIN-FASTON
PACKARD
58 SERIES
02965471
COMPANY
SERIES
02965580
PART NO
02965469
02965470
PLAIN
BRASS
AMP
95
AMP, PACKARD 58
VB1-01
CONTURA X BOOT
8
MARKING DETAIL
REAR VIEW
VC2
4
PACKARD 630
13 2
7 6
B
A
1.466[37.24]
VC2
VC1
6
AMP
82 1
VC2
CONNECTOR HOUSING
(For AMP terminals only)
3
9
A
B
10
MARKING DETAIL
FRONT VIEW
1.266[32.16]
.757[19.23]
.900 [22.86]
TOP
HOLD FLUSH ON BRACKET AND PUSH
IN
TOP
INSERT POINTS UNDER
ACTUATOR
VRT
ACTUATOR REMOVAL
TOOL
(For flush bracket)
1.050[26.67]
AMP, PACKARD 58
71 8
VC1
CONNECTOR HOUSING
3
PACKARD 630
B
4
VC1
A
MARKING DETAIL
FRONT VIEW
10 2
1.266[32.16]
06288318
12084590
12015870
12052224
12015869
60253-2
TIN
PLATED
BRASS
10 5.0
TANG SYMBOL =
12052222
12020035
NOTE: Consult Delphi Packard and/or Amp on actual part numbers and availability.
AMP is a registered trademark of AMP Inc. Harrisburg, PA
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio
60295-2
42100-2
Q.C. SELECTION GUIDE
12010601
2.000[50.80]
3.99 [101.35]
1.466[37.24]
AMP, PACKARD 58
PACKARD 630
MARKING DETAIL
REAR VIEW
5
SHOWS ORIENTATION OF TANG IN SLOT
VCH
CONNECTOR HOUSING
MARKING DETAIL
FRONT VIEW
.920[23.37]
.920[23.37]
1.170[29.72]
1.250[31.75]
2
6
AMP, PACKARD 58
7
PACKARD 630
A
B
54
MARKING DETAIL
REAR VIEW
.770[19.56]
MM
(REF)
3.012
(2)1.0-2.0(2)16-14
.950[24.13]
SYMBOL
TANG
ORIEN-
TATION
.5-.820-18
1.0-2.016-14
AWG
B
WIRE
RANGE
.5-.8
.35-.5
20-18
20-22
.8-2
1.3-316-12
(2)22-18
16-14
18-14
A
.3-.9
B
1.0-2.0
12 3.0
(2).5-.8
22-18
(2) 1.3(2) 16
.820[20.83]
.820[20.83]
60295-1
42100-1
60253-1
12015832
PACKARD
METRI-PACK
630 SERIES
AMP
250 SERIES
FASTIN-FASTON
PACKARD
58 SERIES
02965471
COMPANY
SERIES
02965580
PART NO
02965469
02965470
PLAIN
BRASS
AMP
95
AMP, PACKARD 58
VB1-01
CONTURA X BOOT
8
MARKING DETAIL
REAR VIEW
VC2
4
PACKARD 630
13 2
7 6
B
A
1.466[37.24]
VC2
VC1
6
AMP
82 1
VC2
CONNECTOR HOUSING
(For AMP terminals only)
39
A
B
10
MARKING DETAIL
FRONT VIEW
1.266[32.16]
.757[19.23]
.900 [22.86]
TOP
HOLD FLUSH ON BRACKET AND PUSH
IN
TOP
INSERT POINTS UNDER
ACTUATOR
VRT
ACTUATOR REMOVAL
TOOL
(For flush bracket)
1.050[26.67]
AMP, PACKARD 58
71 8
VC1
CONNECTOR HOUSING
3
PACKARD 630
B
4
VC1
A
MARKING DETAIL
FRONT VIEW
10 2
1.266[32.16]
06288318
12084590
12015870
12052224
12015869
60253-2
TIN
PLATED
BRASS
10 5.0
TANG SYMBOL =
12052222
12020035
NOTE: Consult Delphi Packard and/or Amp on actual part numbers and availability.
AMP is a registered trademark of AMP Inc. Harrisburg, PA
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio
60295-2
42100-2
Q.C. SELECTION GUIDE
12010601
2.000[50.80]
3.99 [101.35]
1.466[37.24]
AMP, PACKARD 58
PACKARD 630
MARKING DETAIL
REAR VIEW
5
SHOWS ORIENTATION OF TANG IN SLOT
VCH
CONNECTOR HOUSING
MARKING DETAIL
FRONT VIEW
.920[23.37] .920[23.37]
1.170[29.72]
1.250[31.75]
2
6
AMP, PACKARD 58
7
PACKARD 630
A
B
54
MARKING DETAIL
REAR VIEW
.770[19.56]
MM
(REF)
3.012
(2)1.0-2.0(2)16-14
.950[24.13]
SYMBOL
TANG
ORIEN-
TATION
.5-.820-18
1.0-2.016-14
AWG
B
WIRE
RANGE
.5-.8
.35-.5
20-18
20-22
.8-2
1.3-316-12
(2)22-18
16-14
18-14
A
.3-.9
B
1.0-2.0
12 3.0
(2).5-.8
22-18
(2) 1.3(2) 16
.820[20.83]
.820[20.83]
60295-1
42100-1
60253-1
12015832
PACKARD
METRI-PACK
630 SERIES
AMP
250 SERIES
FASTIN-FASTON
PACKARD
58 SERIES
02965471
COMPANY
SERIES
02965580
PART NO
02965469
02965470
PLAIN
BRASS
AMP
95 AMP, PACKARD 58
VB1-01
CONTURA X BOOT
8
MARKING DETAIL
REAR VIEW
VC2
4
PACKARD 630
13 2
7 6
B
A
1.466[37.24]
VC2
VC1
6
AMP
82 1
VC2
CONNECTOR HOUSING
(For AMP terminals only)
3
9
A
B
10
MARKING DETAIL
FRONT VIEW
1.266[32.16]
.757[19.23]
.900 [22.86]
TOP
HOLD FLUSH ON BRACKET AND PUSH
IN
TOP
INSERT POINTS UNDER
ACTUATOR
VRT
ACTUATOR REMOVAL
TOOL
(For flush bracket)
1.050[26.67]
AMP, PACKARD 58
71 8
VC1
CONNECTOR HOUSING
3
PACKARD 630
B
4
VC1
A
MARKING DETAIL
FRONT VIEW
10 2
1.266[32.16]
06288318
12084590
12015870
12052224
12015869
60253-2
TIN
PLATED
BRASS
10 5.0
TANG SYMBOL =
12052222
12020035
NOTE: Consult Delphi Packard and/or Amp on actual part numbers and availability.
AMP is a registered trademark of AMP Inc. Harrisburg, PA
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio
60295-2
42100-2
Q.C. SELECTION GUIDE
12010601
2.000[50.80]
3.99 [101.35]
1.466[37.24]
AMP, PACKARD 58
PACKARD 630
MARKING DETAIL
REAR VIEW
5
SHOWS ORIENTATION OF TANG IN SLOT
VCH
CONNECTOR HOUSING
MARKING DETAIL
FRONT VIEW
.920[23.37]
.920[23.37] 1.170[29.72]
1.250[31.75]
2
6
AMP, PACKARD 58
7
PACKARD 630
A
B
54
MARKING DETAIL
REAR VIEW
.770[19.56]
MM
(REF)
3.012
(2)1.0-2.0(2)16-14
.950[24.13]
SYMBOL
TANG
ORIEN-
TATION
.5-.820-18
1.0-2.016-14
AWG
B
WIRE
RANGE
.5-.8
.35-.5
20-18
20-22
.8-2
1.3-316-12
(2)22-18
16-14
18-14
A
.3-.9
B
1.0-2.0
12 3.0
(2).5-.8
22-18
(2) 1.3(2) 16
.820[20.83]
.820[20.83]
60295-1
42100-1
60253-1
12015832
PACKARD
METRI-PACK
630 SERIES
AMP
250 SERIES
FASTIN-FASTON
PACKARD
58 SERIES
02965471
COMPANY
SERIES
02965580
PART NO
02965469
02965470
PLAIN
BRASS
AMP
95 AMP, PACKARD 58
VB1-01
CONTURA X BOOT
8
MARKING DETAIL
REAR VIEW
VC2
4
PACKARD 630
13 2
7 6
B
A
1.466[37.24]
VC2
VC1
6
AMP
82 1
VC2
CONNECTOR HOUSING
(For AMP terminals only)
39
A
B
10
MARKING DETAIL
FRONT VIEW
1.266[32.16]
.757[19.23]
.900 [22.86]
TOP
HOLD FLUSH ON BRACKET AND PUSH
IN
TOP
INSERT POINTS UNDER
ACTUATOR
VRT
ACTUATOR REMOVAL
TOOL
(For flush bracket)
1.050[26.67]
AMP, PACKARD 58
71 8
VC1
CONNECTOR HOUSING
3
PACKARD 630
B
4
VC1
A
MARKING DETAIL
FRONT VIEW
10 2
1.266[32.16]
06288318
12084590
12015870
12052224
12015869
60253-2
TIN
PLATED
BRASS
10 5.0
TANG SYMBOL =
12052222
12020035
NOTE: Consult Delphi Packard and/or Amp on actual part numbers and availability.
AMP is a registered trademark of AMP Inc. Harrisburg, PA
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio
60295-2
42100-2
Q.C. SELECTION GUIDE
12010601
2.000[50.80]
3.99 [101.35]
1.466[37.24]
AMP, PACKARD 58
PACKARD 630
MARKING DETAIL
REAR VIEW
5
SHOWS ORIENTATION OF TANG IN SLOT
VCH
CONNECTOR HOUSING
MARKING DETAIL
FRONT VIEW
.920[23.37] .920[23.37] 1.170[29.72]
1.250[31.75]
2
6
AMP, PACKARD 58
7
PACKARD 630
A
B
54
MARKING DETAIL
REAR VIEW
.770[19.56]
MM
(REF)
3.012
(2)1.0-2.0(2)16-14
.950[24.13]
SYMBOL
TANG
ORIEN-
TATION
.5-.820-18
1.0-2.016-14
AWG
B
WIRE
RANGE
.5-.8
.35-.5
20-18
20-22
.8-2
1.3-316-12
(2)22-18
16-14
18-14
A
.3-.9
B
1.0-2.0
12 3.0
(2).5-.8
22-18
(2) 1.3(2) 16
.820[20.83]
.820[20.83]
60295-1
42100-1
60253-1
12015832
PACKARD
METRI-PACK
630 SERIES
AMP
250 SERIES
FASTIN-FASTON
PACKARD
58 SERIES
02965471
COMPANY
SERIES
02965580
PART NO
02965469
02965470
PLAIN
BRASS
AMP
95 AMP, PACKARD 58
VB1-01
CONTURA X BOOT
8
MARKING DETAIL
REAR VIEW
VC2
4
PACKARD 630
13 2
7 6
B
A
1.466[37.24]
VC2
VC1
6
AMP
82 1
VC2
CONNECTOR HOUSING
(For AMP terminals only)
39
A
B
10
MARKING DETAIL
FRONT VIEW
1.266[32.16]
.757[19.23]
.900 [22.86]
TOP
HOLD FLUSH ON BRACKET AND PUSH
IN
TOP
INSERT POINTS UNDER
ACTUATOR
VRT
ACTUATOR REMOVAL
TOOL
(For flush bracket)
1.050[26.67]
AMP, PACKARD 58
71 8
VC1
CONNECTOR HOUSING
3
PACKARD 630
B
4
VC1
A
MARKING DETAIL
FRONT VIEW
10 2
1.266[32.16]
06288318
12084590
12015870
12052224
12015869
60253-2
TIN
PLATED
BRASS
10 5.0
TANG SYMBOL =
12052222
12020035
NOTE: Consult Delphi Packard and/or Amp on actual part numbers and availability.
AMP is a registered trademark of AMP Inc. Harrisburg, PA
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio
60295-2
42100-2
Q.C. SELECTION GUIDE
12010601
2.000[50.80]
3.99 [101.35]
1.466[37.24]
AMP, PACKARD 58
PACKARD 630
MARKING DETAIL
REAR VIEW
5
SHOWS ORIENTATION OF TANG IN SLOT
VCH
CONNECTOR HOUSING
MARKING DETAIL
FRONT VIEW
.920[23.37] .920[23.37] 1.170[29.72]
1.250[31.75]
2
Additional V-Series Ratings
1 .4VA @ 28VDC Resistive
4 10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, No Agency Listings
51 10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, UL Recognized, CSA Certied
62 15A 125VAC 1/2 HP, 12(2)A 125 VAC μ T85
72 15A 125VAC 1/2 HP, 12(6)A 125 VAC T85
82 10A 250VAC, 15A 125VAC, 1/2 HP 125-250VAC, 12(2)A 250 VAC μ T85
92 10A 250VAC, 15A 125VAC, 1/2 HP 125-250VAC, 12(6)A 250 VAC T85
B 15A 24V
C 20A 18V
D 20A 12V
E 20A 14V, 10A 14VT (circuits 1, 4, A, & D only)
F 10A 14V, 6A, 14VT (circuit G only)
G 20A 6V
H 20A 3V
L 15A 125 VAC, 10A 250VAC, 1/2 HP 125-250 VAC; 6A 125 VAC L
M .4VA/20A 12V (combi-contact)
(combination gold/silver contacts for borderline dry circuit applications)
N .4VA/15A 24V (combi-contact)
(combination gold/silver contacts for borderline dry circuit applications)
NOTES
Consult factory to determine availability for individual circuits and their HP rating.
1. Not avaiable with Contura 7 or 14 rocker styles.
2. Ratings 6 - 9 are UL, CSA & VDE certied, require terminations A or B for double
pole circuits, & are not available with illumination circuits 4, 8, D, J, N, & T or with
wire lead or solder lug terminations.
Circuits 1, 4, A, D, H, M & E are not available with rating 6 & 8. Rating 7 & 9 only available
with circuits 1, 4, A & D. Circuits 2, 3, 5, 7, 8, K, L are 1/2 HP 250VAC only with rating 8.
Ratings 6 & 7 must specify lamp code 1 (125VAC neon). Ratings 8 & 9 must specify lamp
code 2 (250VAC neon). Rating L available with circuits 1, 4, A & D only.
Easily integrate Contura products into your system, with Contura Accessories
Contura Connectors
Contura X Boot (P/N VB1-01)
Contura II, III, IV & V Actuator Removal Tool
(P/N VRT)
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
22 |V-Series Contura Sealed Rocker Switch Accessories
DETAIL VIEW
VH2,VH4 & VH6
HOLE PLUGS
(With wing serrations)
.830 [21.08] VHP
CONTURA II,III HOLE PLUG
1.820 [46.23]
.430 [10.92] VHP
CONTURA II,III HOLE PLUG
(TYP. FOR VH3 & VH4) VH3
CONTURA IV HOLE PLUG
(No wing serrations)
(TYP. FOR VH5 & VH6)
VH5
CONTURA V HOLE PLUG
(No wing serrations)
DETAIL VIEW
VH1,VH3 & VH5
HOLE PLUGS
(No wing serrations
for ease of removal)
VH1
STANDARD HOLE PLUG
(No wing serrations)
(With VC1 connector attached)
TEST CUT
HOLE IN
ACTUAL
MATERIAL
1.450 [36.83]
VH6
CONTURA V HOLE PLUG
(With wing serrations)
VH4
CONTURA IV HOLE PLUG
(With wing serrations)
1.020 [25.91]
1.240 [31.50]
VH2
STANDARD HOLE PLUG
(With wing serrations)
2.000 [50.80]
1.067 [27.10]
1.928 [48.97]
Contura Hole Plug
Dimensional Specifications: in. [mm]
Contura Mounting Panels
Dimensional Specifications: in. [mm]
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
| 23
Notes
* Intentionally left blank
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: sales@carlingtech.com • www.carlingtech.com
East Region Sales Oce, CT • ersm@carlingtech.com
Midwest Region Sales Oce, IL • mrsm@carlingtech.com
West Region Sales Oce, CA • wrsm@carlingtech.com
Asia-Pacic Headquarters
Carling Technologies, Asia-Pacic Ltd.,
Kowloon, Hong Kong
Int + 852-2737-2277 • Fax: Int + 852-2736-9332
Email: sales@carlingtech.com.hk
Shenzhen, China • shenzhen@carlingtech.com
Shanghai, China • shanghai@carlingtech.com
Pune, India • india@carlingtech.com
Kaohsiung, Taiwan • taiwan@carlingtech.com
Yokohama, Japan • japan@carlingtech.com
Europe/Middle East/Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Int + 44 1392-364422 • Fax: Int + 44 1392-364477
Email: ltd.sales@carlingtech.com
GmbH, Germany • gmbh@carlingtech.com
SAS, France • sas@carlingtech.com
REV_SW_V_06_2014