Product data sheet
Characteristics
RXM4AB2B7
miniature plug-in relay - Zelio RXM - 4 C/O - 24
V AC - 6 A - with LED
Main
Range of product Zelio Relay
Series name Miniature
Product or component
type
Plug-in relay
Device short name RXM
Contacts type and
composition
4 C/O
Contacts operation Standard
Control circuit voltage 24 V AC
[Ithe] conventional
enclosed thermal
current
6 A at <= 55 °C
Status LED With
Control type Pushbutton
Coil interference
suppression
Without
Utilisation coefficient 20 %
Sale per indivisible
quantity
10
Complementary
[Ui] rated insulation voltage 250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
[Uimp] rated impulse withstand voltage 4 kV conforming to IEC 61000-4-5
Contacts material Silver alloy (Ag/Ni)
[Ie] rated operational current 3 A (AC-1/DC-1) NC conforming to IEC
6 A (AC-1/DC-1) NO conforming to IEC
8 A (AC-1/DC-1) conforming to UL
Minimum switching current 10 mA
Maximum switching voltage 250 V AC/DC
Minimum switching voltage 17 V
Resistive rated load 6 A at 250 V AC
6 A at 28 V DC
Maximum switching capacity 1500 VA, AC circuit
168 W, DC circuit
Minimum switching capacity 170 mW
Operating rate <= 20 cyc/mn (under load)
<= 300 cyc/mn (no-load)
Mechanical durability 10000000 cycles
Electrical durability 100000 cycles for resistive load
Average consumption in W 0.9 W, DC circuit
Average consumption in VA 1.2, AC circuit
Drop-out voltage threshold >= 0.1 Uc (DC
>= 0.15 Uc (AC
Operating time 20 ms between coil de-energisation and making of the Off-delay contact (AC/DC)
20 ms between coil energisation and making of the On-delay contact (AC/DC)
Average resistance 180 Ohm, AC circuit at 20 °C +/- 15 %
Rated operational voltage limits 19.2...26.4 V AC
Protection category RT I
Operating position Any position
CAD overall width 21 mm