Handheld Oscilloscopes THS3000 Series Data Sheet Measurement and Analysis 21 Automatic Measurements Waveform Math and FFT Spectral Analysis Volts, Time, Frequency, Watts Cursor Measurements Application Functions Measurement Data Logging with TrendPlotTM Waveform Pass/Fail Limit Testing Automatic 100 Display Screens Recorder Ease of Use Features 6 in. (153 mm) Bright Color Display USB Device and Host Support 7 Hours of Continuous Battery Operation Applications Features & Benefits Embedded Analog and Digital Design Key Performance Specifications Power Devices, Power Electronics, and Power Supply Design 100 MHz or 200 MHz Bandwidth Models Maximum Sample Rates up to 5 GS/s and 200 ps Resolution 4 Fully Isolated and Floating Channels 600 VRMS CAT III, 1000 VRMS CAT II Rated Inputs (BNC to Earth Ground) Automotive and Avionics Design and Maintenance Industrial Equipment Design and Installation Field Test and Service Data Sheet Isolated-channel technology is specified to 1000 VRMS maximum float voltage. Four isolated input channels easily handle any type of mixed signal inputs. Portable Performance for Challenging Environments With 4 isolated channels and up to 7 hours of battery life, the lightweight THS3000 Handheld Oscilloscope Series enables you to safely make floating or differential measurements on your bench or in the field. Now you can tackle tough environments with the performance you expect from Tektronix - safely and affordably. Accurately Measure Your Signals With up to 200 MHz bandwidth, 4 channels, and 5 GS/s maximum sample rate, no other oscilloscope offers as much bandwidth and sample rate in a portable handheld form factor. The THS3000 Handheld Oscilloscope Series has 10,000 points record length per channel, enabling you to capture more signal information at higher sample rates to clearly see signal details. For applications where it is important to measure slow-changing signals over long time periods, the THS3000 Series offers Roll mode that extends the record length to 30,000 points of signal information. Safely Make Floating and Differential Measurements Making accurate and safe measurements on power electronics, power semiconductors, and other electronics applications can be challenging when the signal reference is floating and not referenced to earth ground. When your signal ranges from low voltage to high voltage (kV) or you must use probing techniques that can potentially create ground loops, the problem is compounded. To enable floating measurements, the THS3000 Series is architecturally different than most other oscilloscopes. All input channels are fully isolated 2 www.tektronix.com Input signal and float voltage maximum safety ratings. from the main chassis and from each other. Additionally the power adapter and USB interface are fully isolated to ensure safe measurements and eliminate the risk of unintentional grounding or accidental short circuits. When configured with the proper probes you can be assured you'll be able to make quick, safe, and accurate measurements. Selecting the Right Probe Scope/Probe (Attenuation) Maximum Safety Rating 600 VRMS CAT III 1000 VRMS CAT II 300 VRMS THP0301 (10X) CAT III P5150 (50X) 600 VRMS CAT II THS3000 (1X input) P5122 (100X) THS3000 Viewable Signal Reference Input Signal On-screen On-screen Safety Float Safety P-P Voltage RMS Voltage Rating Rating*1 600 VRMS CAT II 300 VRMS CAT III 800 Vp-p 282 VRMS 300 VRMS CAT III 1000 VRMS CAT II 1000 VRMS CAT II 849 Vp-p 300 VRMS 2828 Vp-p 1000 VRMS 2828 Vp-p 1000 VRMS *1 Passive probe reference leads have no attenuation so any working voltage or overvoltage transients pass straight through to the scope reference. Thus, a passive probe reference float rating can never exceed the scope reference float rating. Handheld Oscilloscopes -- THS3000 Series Analyze measurements and recordings visually or using measurement cursors. Playback of captured data is quick and easy with the THS3000 Series oscilloscopes. Fast Analysis of Your Device The THS3000 Handheld Oscilloscope Series is packed with analysis tools to help you validate your device's operation and identify issues quickly. With waveform math, you can add, subtract, or multiply any of your signals to investigate instantaneous power or look at gain. Vertical and horizontal cursors allow you to look at a specific point on your waveform for accurate measurements of voltage, current, time, or frequency. With 21 automated measurements, you can make common measurements quickly and accurately. The built-in Fast Fourier Transform (FFT) function allows you to see the frequency spectrum of your signal, revealing signal interference, crosstalk, or switching noise. Find Intermittent Faults with TrendPlotTM Intermittent faults can be caused by timing errors, temperature changes, environmental influences, or simply broken wiring or connectors. The TrendPlotTM function helps you find those faults by plotting minimum and maximum measurement values over time. You can select up to 4 measurements and plot any combination of voltages, amps, frequency, time, and phase for any or all four inputs, all with time capture information. Automatic Capture and Data Logging of 100 Display Screens Capturing random or changing signals can often be difficult. The THS3000 Series greatly simplifies any type of waveform data logging by continuously capturing 100 display screens. Each screen capture can include multiple channels and math waveforms, each with its own time stamp. Data capture can also be tailored to specific events by selection of User-defined limit testing can easily identify random waveform anomalies. qualified trigger conditions. Playback is quick and easy with the automatic replay of all captured screens or only the screens you select. Waveform Limit Testing The THS3000 Series can automatically monitor your signals and output Pass or Fail results by judging whether the input waveform is within predefined boundaries. User selections can include testing one or all input channels and automatic recording of Pass or Fail data. Data can easily be reviewed using the Replay mode or stored externally to a USB memory device. www.tektronix.com 3 Data Sheet Easily calculate the instantaneous power by multiplying voltage and current waveforms. Tektronix OpenChoice(R) desktop software extends the capabilities of your instrument. Complete Solution for Power Measurements For performing power measurement on motor drives, power converters/inverters, and power semiconductor devices the THS3000 Series is equipped to handle most common measurements. For basic debugging, the isolated input channels can be used with a variety of voltage and current probes. Each input channel can be configured to match the probe type and attenuation ensuring correct measurements and cursor readings. Four channels allow for easy measurements of three-phase power or simultaneous capture of digital control and power signals. Measurements on power conversion electronics usually require probes with higher voltage ratings. Tektronix offers a passive probe with insulation systems specifically designed for making floating measurements. The standard THP0301-X can measure up to 849 Vp-p (300 VRMS). Optional P5122 probes, when coupled with the THS3000 Series, are suitable for making measurements on 1000 VRMS devices in Category II environments, with a maximum float voltage of up to 600 VRMS relative to earth ground. Designed to Make Your Work Easier Intuitive Operation The THS3000 Handheld Oscilloscope Series has a front-panel layout and an intuitive user interface which makes the instrument easy to use, reducing learning time and increasing efficiency. For initial setup or for situations where you're constantly changing connection points, the THS3000 Series has a single-button Autoset and Autorange feature which can automatically set up the trigger system and adjust vertical and/or horizontal oscilloscope settings. Easy to Use The bright color display makes it easy for you to see the signals you're measuring. Each waveform is color coded and designed to correspond to the colors on the input probe connectors, the front-panel channel selector 4 www.tektronix.com The standard USB ports facilitate data storage, data transfer, and instrument control. buttons, and the individual probes which are colored at both ends. By matching the colors during setup you'll be assured you can easily identify your waveforms. For setup assistance user messages are available in 11 user-selectable languages including English, French, German, Spanish, Portuguese, Italian, Japanese, Simplified and Traditional Chinese, Korean, and Russian. Flexible Data Transfer The THS3000 Series oscilloscopes come with both a USB host and USB mini port located on the side panel enabling you to quickly and easily save instrument settings, screenshots, and waveform data onto a flash device or transfer the data directly to a PC. The THS3000 Series is shipped with the Tektronix OpenChoice(R) desktop software, allowing you to integrate your new THS3000 Series oscilloscope into existing measurement systems and take advantage of extended functionalities in data acquisition, measurement analysis, and documentation. Handheld Oscilloscopes -- THS3000 Series Versatility and Portability for Wherever Your Job Takes You With a battery life of 7 hours and a weight of only 4.8 lb. (2.2 kg) the THS3000 Handheld Oscilloscope Series offers ultimate portability. Measurements taken in the lab can now be conveniently correlated with those taken in the field - all on the same instrument. Rated IP41, the THS3000 Series features the ruggedness needed to go beyond the lab and into industrial and field environments. The optional travel kit comes with a hard-sided carrying case and useful accessories allowing you to take the THS3000 Series on the road securely and conveniently. From the lab to the field, the THS3000 Handheld Oscilloscope Series offers you the versatility of using a single, high-performance instrument suitable for a wide range of working environments. Performance You Can Count On In addition to industry-leading service and support, every THS3000 Series oscilloscope comes backed with a three-year standard warranty, and ships with a Certificate of Traceable Calibration Standard. Characteristics Vertical System Analog Channels Characteristic Isolated Input Channels Analog Bandwidth (-3 dB) Rise Time Hardware Bandwidth Limits Input Coupling Input Impedance Input Sensitivity Range Vertical Resolution DC Gain Accuracy Max BNC Input Voltage Max Probe Voltage (with standard THP0301-X probe) Float Voltage Trace Positioning THS3014 THS3024 4 4 100 MHz 200 MHz 3.5 ns 1.7 ns 20 kHz, 20 MHz, or full AC, DC 1 M 1%, 14 pF 2 pF 2 mV/div to 100 V/div 8 bits 2.1% of reading +0.04 x range/div for 5 mV/div to 100 V/div (1 M) 300 VRMS CAT III from BNC signal to BNC shell 300 VRMS CAT III from 10:1 probe tip signal to BNC and reference lead 1000 VRMS CAT II / 600 VRMS CAT III from BNC shell to earth ground 4 divisions The optional travel kit (TK) version includes a hard-sided carry case for your instrument, accessories, and storage space for a laptop PC. Trigger System Characteristic Description Input Source Channel 1, 2, 3, or 4. All input references isolated from each other and earth ground Auto-level, Auto, Normal, and Single DC, HF Reject, Noise Reject (reduces sensitivity) Main Trigger Modes Trigger Coupling Trigger Sensitivity Characteristic Description Internal DC Coupled 0.5 divisions from DC to 5 MHz at >5 mV/div 1 divisions >5 MHz to 200 MHz (THS3024) 1 divisions >5 MHz to 100 MHz (THS3014) Trigger Level Range Characteristic Description Any Channel 4.0 divisions Trigger Modes Horizontal System Mode Description Characteristic Edge Positive, negative, or dual slope on any input channel. Coupling includes DC, HF Reject, and Noise Reject Trigger on Channel 1, width of positive or negative pulses (glitches) that are >, <, =, or a specified period of time (resolution of 0.01 div with minimum time of 50 ns) Trigger on N-th occurrence of trigger (N selectable from 2 to 99) Trigger on Channel 1, line number, all lines, odd, even, or all fields on NTSC, PAL, PAL Plus, and SECAM signals Trigger on Channel 1, high-res non-interlaced video with line frequencies from 14 kHz to 65 kHz Maximum Sample Rate Maximum Record Length (All channels) Time-base Range (s/div) Delay Time Range Timing Accuracy Zoom THS3014 THS3024 2.5 GS/s (1.25 GS/s 4-ch) 5 GS/s (1.25 GS/s 4-ch) 10,000 points (30,000 points in Roll mode (4 ms to 2 min / div)) 5 ns to 4 s 2 ns to 4 s 1 full screen (12 divisions) of pre-trigger or up to 100 screens (1,200 divisions) of post-trigger 100 ppm + 0.04 div Horizontally expand or compress a live or stopped waveform Pulse Width Event Video Non-interlaced www.tektronix.com 5 Data Sheet Acquisition Modes Storage Memory Mode Description Characteristic Description Sample (Default) Glitch Detect Acquire sampled values Captures high frequency or glitches as narrow as 8 ns from 5 s to 120 s / div Selectable from 2, 4, 8, or 64 waveforms Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 4 ms/div Automatic data logging of 100 triggered records (screens) with date and time stamp. Store internally or to a USB device Visually compare against user-definable reference waveforms or perform automatic Pass or Fail testing of 1 to 4 channels with data logging of test results Reference Waveform 4 user-definable reference traces Stores 30 internal scope records (4 traces each) with screen image and corresponding setup Store 10 internal recordings that can be a 100-screen replay sequence, a Roll-mode recording, or a TrendPlotTM measurement recording Store up to 9 internally or 256 BMP images to an external USB storage drive Time and date stamp of all stored data Averaging Roll Data Recorder Waveform Compare Mode Description Autoset Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems Continuous auto-setup of vertical, horizontal, and trigger systems that track signal changes Waveform Measurements Characteristic Description Cursors Time, Freq (1/T), Volts, Watts, Rise/Fall Time from any input channel or math waveform 21. Up to 4 can be displayed on-screen at any one time. Measurements include: V DC, V ACRMS, V AC+DC, VPeak Max, VPeak Min, Peak to Peak, A DC, A AC, A AC+DC, Frequency, Rise Time (using cursors), Fall Time (using cursors), Phase (between any 2 inputs), Positive Pulse Width, Negative Pulse Width, Positive Duty Cycle, Negative Duty Cycle, dBV, dBm into 50 and 600 Records and graphically displays any 4 automatic scope measurements. Store internally or to USB flash drive for recall and analysis Automatic Measurements TrendPlotTM Waveform Math Characteristic Description Arithmetic FFT Add, subtract, and multiply waveforms Spectral magnitude. Set FFT Vertical Scale to Linear or Logarithmic, and FFT Window to Automatic, Hamming, Hanning, or None Display Characteristics Characteristic Description Display Type Display Resolution Waveform Style 6 in. (153 mm) Liquid-crystal Color Display 320 horizontal x 240 vertical pixels Vectors (dot-join), Dots, Envelope, Variable Persistence, Infinite Persistence YT and XY Display Format 6 Screen Image Real-time Clock Input/Output Ports Port Automatic Setup Autorange Recording www.tektronix.com Description USB Host Port USB Device Port Supports USB mass storage devices Mini-USB-B connector allows for communication/control of oscilloscope Probe Compensator Side-panel Output - Output Amplitude: 1.225 Vp-p Frequency: 500 Hz Kensington-style Lock Side-panel security slot connects to standard Kensington-style lock Software Product Description OpenChoice(R) Desktop Enables fast and easy communication between a Windows PC and the THS3000 Series. Transfer and save settings, waveforms, and screen images Power Source Characteristic Description Battery Battery Charging Time Line Power Power Source Voltage Power Source Frequency 7 hour, 10.8 V rechargeable Li-Ion battery 5 hours AC power adapter/charger 100 V to 240 V AC 10% 50 Hz to 60 Hz Physical Characteristics Dimension mm in. Height Width Depth 265 190 70 10.5 7.5 2.8 Weight kg lb. Net (with battery) Shipping (Base model) Shipping (TK model) 2.2 4.7 7.8 4.8 10.4 17.1 Handheld Oscilloscopes -- THS3000 Series Environmental Recommended Accessories Characteristic Description Accessory Description Enclosure Temperature Operating IP 41 according to IEC60529 THSBAT THSCHG ACHHS HCHHS 376-0255-xx 020-3085-xx 119-7900-00 Additional spare battery Battery charger (does not include AC power adapter) Instrument soft case Instrument hard case (standard with TK models) Versatile hanging hook Probe replacement accessory kit AC power adapter Nonoperating Humidity Operating Nonoperating Altitude Operating Nonoperating Vibration/Shock Operating Nonoperating Regulatory Electromagnetic Compatibility Safety 0 C to +40 C (with battery) 0 C to +50 C (without battery) -20 C to +60 C 10 C to 30 C, up to 95% relative humidity, noncondensing 30 C to 40 C, up to 75% relative humidity, noncondensing 40 C to 50 C, up to 45% relative humidity, noncondensing -20 C to 60 C, relative humidity, noncondensing Up to 3,000 m (9,843 ft.) Up to 12,000 m (39,370 ft.) Vibration (Sinusoidal): 3 g max, according to MIL-PRF-28800F, Class 2 Shock: 30 g max, according to MIL-PRF-28800F, Class 2 Vibration (Random): 0.03 g2/Hz, according to MIL-PRF-2800F, Class 2 Probe Description A621 A622 P5122 P5150 CT2 TCP303/TCPA300 TCP305/TCPA300 TCP312/TCPA300 TCP404XL/TCPA400 2000 A, 5 kHz to 50 kHz AC current probe/BNC 100 A, 100 kHz AC/DC current probe/BNC 200 MHz passive 100X high-voltage probe 500 MHz passive 50X high-voltage probe*2 2.5 A, 200 MHz AC current probe 150 A, 15 MHz AC/DC current probe/amplifier 50 A, 50 MHz AC/DC current probe/amplifier 30 A, 100 MHz, AC/DC current probe/amplifier 500 A, 2 MHz AC/DC current probe/amplifier *2 The P5150 is fully compatible with THS oscilloscopes, but 50X vertical scaling is not offered. EN 61326-1:2006, EN 61326-2-1:2006 for emission and immunity UL61010-1:2004; CAN/CSA C22.2 No. 61010.1-04; EN61010-1:2001, Pollution Degree 2; ANSI/ISA-82.02.01 Ordering Information THS3000 Models Model Description THS3014 THS3014-TK 100 MHz, 2.5 GS/s, 4-channel handheld oscilloscope 100 MHz, 2.5 GS/s, 4-channel handheld oscilloscope with travel kit 200 MHz, 5 GS/s, 4-channel handheld oscilloscope 200 MHz, 5 GS/s, 4-channel handheld oscilloscope with travel kit THS3024 THS3024-TK Recommended Probes International Power Plugs Option Description Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. North America power Universal Euro power United Kingdom power Australia power Switzerland power Japan power China power India power A0 A1 A2 A3 A5 A6 A10 A11 Warranty Three-year warranty covering all parts and labor, excluding probes. All Models Include: THP0301-Y/B/M/G 300 MHz 10X Passive Probes, Lithium-ion Battery with 7-hour battery life, Carrying Handle, Hanging Strap, USB-A to Mini USB-B Cable for PC communication, Installation/Safety Manual, Documentation CD (available in English, French, German, Spanish, Italian, Portuguese, Korean, Japanese, Simplified Chinese, Traditional Chinese, and Russian) (063-4379-xx), AC Power Adapter with Power Cord, ACHHS Soft-sided Carry Case (standard with base model), OpenChoice(R) Desktop PC Communication Software, Calibration Certificate Documenting Traceability to National Metrology Institute(s) and ISO9001 Quality System Registration, Three-year Warranty. TK Models Also Include: Hard-sided travel case, soft-sided probe case, 2 probe replacement accessory kits. Please specify power plug when ordering. www.tektronix.com 7 Data Sheet Contact Tektronix: ASEAN / Australasia (65) 6356 3900 Austria 00800 2255 4835* Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Belgium 00800 2255 4835* Brazil +55 (11) 3759 7627 Canada 1 800 833 9200 Central East Europe and the Baltics +41 52 675 3777 Central Europe & Greece +41 52 675 3777 Denmark +45 80 88 1401 Finland +41 52 675 3777 France 00800 2255 4835* Germany 00800 2255 4835* Hong Kong 400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835* Japan 81 (3) 6714 3010 Luxembourg +41 52 675 3777 Mexico, Central/South America & Caribbean 52 (55) 56 04 50 90 Middle East, Asia, and North Africa +41 52 675 3777 The Netherlands 00800 2255 4835* Norway 800 16098 People's Republic of China 400 820 5835 Poland +41 52 675 3777 Portugal 80 08 12370 Republic of Korea 001 800 8255 2835 Russia & CIS +7 (495) 7484900 South Africa +41 52 675 3777 Spain 00800 2255 4835* Sweden 00800 2255 4835* Switzerland 00800 2255 4835* Taiwan 886 (2) 2722 9622 United Kingdom & Ireland 00800 2255 4835* USA 1 800 833 9200 * European toll-free number. If not accessible, call: +41 52 675 3777 Updated 10 February 2011 For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tektronix.com Copyright (c) Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies. 10 Nov 2011 www.tektronix.com 3GW-27121-0 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Tektronix: ACHHS HCHHS THSBAT THS3014 THS3014-TK THS3024 THS3024-TK