Handheld Oscilloscopes
THS3000 Series Data Sheet
Features & Benets
Key Performance Specications
100 MHz or 200 MHz Bandwidth Models
Maximum Sample Rates up to 5 GS/s and 200 ps Resolution
4 Fully Isolated and Floating Channels
600 VRMS CAT III, 1000 VRMS CAT II Rated Inputs (BNC to Earth Ground)
Measurement and Analysis
21 Automatic Measurements
Waveform Math and FFT Spectral Analysis
Volts, Time, Frequency, Watts Cursor Measurements
Application Functions
Measurement Data Logging with TrendPlot™
Waveform Pass/Fail Limit Testing
Automatic 100 Display Screens Recorder
Ease of Use Features
6 in. (153 mm) Bright Color Display
USB Device and Host Support
7 Hours of Continuous Battery Operation
Applications
Embedded Analog and Digital Design
Power Devices, Power Electronics, and Power Supply Design
Automotive and Avionics Design and Maintenance
Industrial Equipment Design and Installation
Field Test and Service
Data Sheet
Four isolated input channels easily handle any type of mixed signal inputs.
Portable Performance for Challenging
Environments
With 4 isolated channels and up to 7 hours of battery life, the lightweight
THS3000 Handheld Oscilloscope Series enables you to safely make
oating or differential measurements on your bench or in the eld. Now
you can tackle tough environments with the performance you expect from
Tektronix safely and affordably.
Accurately Measure Your Signals
With up to 200 MHz bandwidth, 4 channels, and 5 GS/s maximum sample
rate, no other oscilloscope offers as much bandwidth and sample rate in a
portable handheld form factor. The THS3000 Handheld Oscilloscope Series
has 10,000 points record length per channel, enabling you to capture more
signal information at higher sample rates to clearly see signal details. For
applications where it is important to measure slow-changing signals over
long time periods, the THS3000 Series offers Roll mode that extends the
record length to 30,000 points of signal information.
Safely Make Floating and Differential
Measurements
Making accurate and safe measurements on power electronics, power
semiconductors, and other electronics applications can be challenging
when the signal reference is oating and not referenced to earth ground.
When your signal ranges from low voltage to high voltage (kV) or you
must use probing techniques that can potentially create ground loops, the
problem is compounded.
To enable oating measurements, the THS3000 Series is architecturally
different than most other oscilloscopes. All input channels are fully isolated
Isolated-channel technology is specied to 1000 VRMS maximum oat voltage.
Input signal and oat voltage maximum safety ratings.
from the main chassis and from each other. Additionally the power adapter
and USB interface are fully isolated to ensure safe measurements and
eliminate the risk of unintentional grounding or accidental short circuits.
When congured with the proper probes you can be assured you’ll be able
to make quick, safe, and accurate measurements.
Selecting the Right Probe
Maximum Safety Rating THS3000 Viewable SignalScope/Probe
(Attenuation) Reference
Float Safety
Rating*1
Input Signal
Safety
Rating
On-screen
P-P Voltage
On-screen
RMS Voltage
THS3000
(1X input)
600 VRMS
CAT III
1000 VRMS
CAT II
300 VRMS
CAT III
800 Vp-p 282 VRMS
THP0301 (10X) 300 VRMS
CAT III
300 VRMS
CAT III
849 Vp-p 300 VRMS
P5150 (50X) 600 VRMS CAT II 1000 VRMS
CAT II
2828 Vp-p 1000 VRMS
P5122 (100X) 600 VRMS CAT II 1000 VRMS
CAT II
2828 Vp-p 1000 VRMS
*1Passive probe reference leads have no attenuation so any working voltage or overvoltage transients pass
straight through to the scope reference. Thus, a passive probe reference oat rating can never exceed the
scope reference oat rating.
2www.tektronix.com
Handheld Oscilloscopes THS3000 Series
Analyze measurements and recordings visually or using measurement cursors.
Fast Analysis of Your Device
The THS3000 Handheld Oscilloscope Series is packed with analysis tools
to help you validate your device’s operation and identify issues quickly. With
waveform math, you can add, subtract, or multiply any of your signals to
investigate instantaneous power or look at gain. Vertical and horizontal
cursors allow you to look at a specic point on your waveform for accurate
measurements of voltage, current, time, or frequency. With 21 automated
measurements, you can make common measurements quickly and
accurately. The built-in Fast Fourier Transform (FFT) function allows you
to see the frequency spectrum of your signal, revealing signal interference,
crosstalk, or switching noise.
Find Intermittent Faults with TrendPlot™
Intermittent faults can be caused by timing errors, temperature changes,
environmental inuences, or simply broken wiring or connectors. The
TrendPlot™ function helps you nd those faults by plotting minimum
and maximum measurement values over time. You can select up to
4 measurements and plot any combination of voltages, amps, frequency,
time, and phase for any or all four inputs, all with time capture information.
Automatic Capture and Data Logging of 100 Display
Screens
Capturing random or changing signals can often be difcult. The
THS3000 Series greatly simplies any type of waveform data logging by
continuously capturing 100 display screens. Each screen capture can
include multiple channels and math waveforms, each with its own time
stamp. Data capture can also be tailored to specic events by selection of
Playback of captured data is quick and easy with the THS3000 Series oscilloscopes.
User-dened limit testing can easily identify random waveform anomalies.
qualied trigger conditions. Playback is quick and easy with the automatic
replay of all captured screens or only the screens you select.
Waveform Limit Testing
The THS3000 Series can automatically monitor your signals and output
Pass or Fail results by judging whether the input waveform is within
predened boundaries. User selections can include testing one or all input
channels and automatic recording of Pass or Fail data. Data can easily be
reviewed using the Replay mode or stored externally to a USB memory
device.
www.tektronix.com 3
Data Sheet
Easily calculate the instantaneous power by multiplying voltage and current waveforms.
Complete Solution for Power Measurements
For performing power measurement on motor drives, power
converters/inverters, and power semiconductor devices the
THS3000 Series is equipped to handle most common measurements. For
basic debugging, the isolated input channels can be used with a variety of
voltage and current probes. Each input channel can be congured to match
the probe type and attenuation ensuring correct measurements and cursor
readings. Four channels allow for easy measurements of three-phase
power or simultaneous capture of digital control and power signals.
Measurements on power conversion electronics usually require probes with
higher voltage ratings. Tektronix offers a passive probe with insulation
systems specically designed for making oating measurements. The
standard THP0301-X can measure up to 849 Vp-p (300 VRMS). Optional
P5122 probes, when coupled with the THS3000 Series, are suitable for
making measurements on 1000 VRMS devices in Category II environments,
with a maximum oat voltage of up to 600 VRMS relative to earth ground.
Designed to Make Your Work Easier
Intuitive Operation
The THS3000 Handheld Oscilloscope Series has a front-panel layout and
an intuitive user interface which makes the instrument easy to use, reducing
learning time and increasing efciency. For initial setup or for situations
where you’re constantly changing connection points, the THS3000 Series
has a single-button Autoset and Autorange feature which can automatically
set up the trigger system and adjust vertical and/or horizontal oscilloscope
settings.
Easy to Use
The bright color display makes it easy for you to see the signals you’re
measuring. Each waveform is color coded and designed to correspond to
the colors on the input probe connectors, the front-panel channel selector
Tektronix OpenChoice®desktop software extends the capabilities of your instrument.
The standard USB ports facilitate data storage, data transfer, and instrument control.
buttons, and the individual probes which are colored at both ends. By
matching the colors during setup you’ll be assured you can easily identify
your waveforms.
For setup assistance user messages are available in 11 user-selectable
languages including English, French, German, Spanish, Portuguese, Italian,
Japanese, Simplied and Traditional Chinese, Korean, and Russian.
Flexible Data Transfer
The THS3000 Series oscilloscopes come with both a USB host and USB
mini port located on the side panel enabling you to quickly and easily save
instrument settings, screenshots, and waveform data onto a ash device or
transfer the data directly to a PC. The THS3000 Series is shipped with the
Tektronix OpenChoice®desktop software, allowing you to integrate your
new THS3000 Series oscilloscope into existing measurement systems and
take advantage of extended functionalities in data acquisition, measurement
analysis, and documentation.
4www.tektronix.com
Handheld Oscilloscopes THS3000 Series
Versatility and Portability for Wherever Your
Job Takes You
With a battery life of 7 hours and a weight of only 4.8 lb. (2.2 kg) the
THS3000 Handheld Oscilloscope Series offers ultimate portability.
Measurements taken in the lab can now be conveniently correlated with
those taken in the eld all on the same instrument. Rated IP41, the
THS3000 Series features the ruggedness needed to go beyond the lab and
into industrial and eld environments. The optional travel kit comes with a
hard-sided carrying case and useful accessories allowing you to take the
THS3000 Series on the road securely and conveniently. From the lab to the
eld, the THS3000 Handheld Oscilloscope Series offers you the versatility
of using a single, high-performance instrument suitable for a wide range of
working environments.
Performance You Can Count On
In addition to industry-leading service and support, every THS3000 Series
oscilloscope comes backed with a three-year standard warranty, and ships
with a Certicate of Traceable Calibration Standard.
Characteristics
Vertical System Analog Channels
Characteristic THS3014 THS3024
Isolated Input Channels 44
Analog Bandwidth (–3 dB) 100MHz 200MHz
Rise Time 3.5 ns 1.7 ns
Hardware Bandwidth
Limits
20 kHz, 20 MHz, or full
Input Coupling AC, DC
Input Impedance 1M±1%, 14 pF ±2 pF
Input Sensitivity Range 2 mV/div to 100 V/div
Vertical Resolution 8 bits
DC Gain Accuracy ±2.1% of reading +0.04 × range/div for
5 mV/div to 100 V/div
Max BNC Input Voltage (1 M)300V
RMS CAT III from BNC signal to BNC shell
Max Probe Voltage (with
standard THP0301-X
probe)
300 VRMS CAT III from 10:1 probe tip signal to
BNC and reference lead
Float Voltage 1000 VRMS CATII/600V
RMS CAT III from BNC
shell to earth ground
Trace Positioning ±4 divisions
Horizontal System
Characteristic THS3014 THS3024
Maximum Sample Rate 2.5 GS/s (1.25 GS/s 4-ch) 5 GS/s (1.25 GS/s 4-ch)
Maximum Record Length
(All channels)
10,000 points (30,000 points in Roll mode
(4 ms to 2 min / div))
Time-base Range (s/div) 5nsto4s 2nsto4s
Delay Time Range 1 full screen (12 divisions) of pre-trigger or up to
100 screens (1,200 divisions) of post-trigger
Timing Accuracy ±100 ppm + 0.04 div
Zoom Horizontally expand or compress a live or
stopped waveform
The optional travel kit (TK) version includes a hard-sided carry case for your instrument,
accessories, and storage space for a laptop PC.
Trigger System
Characteristic Description
Input Source Channel 1, 2, 3, or 4. All input references isolated from
each other and earth ground
Main Trigger Modes Auto-level, Auto, Normal, and Single
Trigger Coupling DC, HF Reject, Noise Reject (reduces sensitivity)
Trigger Sensitivity
Characteristic Description
Internal DC Coupled 0.5 divisions from DC to 5 MHz at >5 mV/div
1 divisions >5 MHz to 200 MHz (THS3024)
1 divisions >5 MHz to 100 MHz (THS3014)
Trigger Level Range
Characteristic Description
Any Channel ±4.0 divisions
Trigger Modes
Mode Description
Edge Positive, negative, or dual slope on any input channel.
Coupling includes DC, HF Reject, and Noise Reject
Pulse Width Trigger on Channel 1, width of positive or negative pulses
(glitches) that are >, <, =, or a specied period of time
(resolutionof0.01divwithminimumtimeof50ns)
Event Trigger on N-th occurrence of trigger (N selectable from 2
to 99)
Video Trigger on Channel 1, line number, all lines, odd, even, or
all elds on NTSC, PAL, PAL Plus, and SECAM signals
Non-interlaced Trigger on Channel 1, high-res non-interlaced video with
line frequencies from 14 kHz to 65 kHz
www.tektronix.com 5
Data Sheet
Acquisition Modes
Mode Description
Sample (Default) Acquire sampled values
Glitch Detect Captures high frequency or glitches as narrow as 8 ns
from 5 μsto120s/div
Averaging Selectable from 2, 4, 8, or 64 waveforms
Roll Scrolls waveforms right to left across the screen at sweep
speeds slower than or equal to 4 ms/div
Data Recorder Automatic data logging of 100 triggered records (screens)
with date and time stamp. Store internally or to a USB
device
Waveform Compare Visually compare against user-denable reference
waveforms or perform automatic Pass or Fail testing of 1
to 4 channels with data logging of test results
Automatic Setup
Mode Description
Autoset Single-button, automatic setup of all channels for vertical,
horizontal, and trigger systems
Autorange Continuous auto-setup of vertical, horizontal, and trigger
systems that track signal changes
Waveform Measurements
Characteristic Description
Cursors Time, Freq (1/T), Volts, Watts, Rise/Fall Time from any
input channel or math waveform
Automatic
Measurements
21. Up to 4 can be displayed on-screen at any one time.
Measurements include:
V DC, V ACRMS, V AC+DC, VPeak Max, VPeak Min, Peak
to Peak, A DC, A AC, A AC+DC, Frequency, Rise Time
(using cursors), Fall Time (using cursors), Phase (between
any 2 inputs), Positive Pulse Width, Negative Pulse Width,
Positive Duty Cycle, Negative Duty Cycle, dBV, dBm into
50 and 600
TrendPlot™ Records and graphically displays any 4 automatic scope
measurements. Store internally or to USB ash drive for
recall and analysis
Waveform Math
Characteristic Description
Arithmetic Add, subtract, and multiply waveforms
FFT Spectral magnitude. Set FFT Vertical Scale to Linear or
Logarithmic, and FFT Window to Automatic, Hamming,
Hanning, or None
Display Characteristics
Characteristic Description
Display Type 6 in. (153 mm) Liquid-crystal Color Display
Display Resolution 320 horizontal × 240 vertical pixels
Waveform Style Vectors (dot-join), Dots, Envelope, Variable Persistence,
Innite Persistence
Display Format YT and XY
Storage Memory
Characteristic Description
Reference 4 user-denable reference traces
Waveform Stores 30 internal scope records (4 traces each) with
screen image and corresponding setup
Recording Store 10 internal recordings that can be a 100-screen
replay sequence, a Roll-mode recording, or a TrendPlot™
measurement recording
Screen Image Store up to 9 internally or 256 BMP images to an external
USB storage drive
Real-time Clock Time and date stamp of all stored data
Input/Output Ports
Port Description
USB Host Port Supports USB mass storage devices
USB Device Port Mini-USB-B connector allows for communication/control of
oscilloscope
Probe Compensator
Output
Side-panel Output
Amplitude: 1.225 Vp-p
Frequency: 500 Hz
Kensington-style Lock Side-panel security slot connects to standard
Kensington-style lock
Software
Product Description
OpenChoice®Desktop Enables fast and easy communication between a
Windows PC and the THS3000 Series. Transfer and save
settings, waveforms, and screen images
Power Source
Characteristic Description
Battery 7 hour, 10.8 V rechargeable Li-Ion battery
Battery Charging Time 5hours
Line Power AC power adapter/charger
Power Source Voltage 100 V to 240 V AC ±10%
Power Source
Frequency
50 Hz to 60 Hz
Physical Characteristics
Dimension mm in.
Height 265 10.5
Width 190 7.5
Depth 70 2.8
Weight kg lb.
Net (with battery) 2.2 4.8
Shipping (Base model) 4.7 10.4
Shipping (TK model) 7.8 17.1
6www.tektronix.com
Handheld Oscilloscopes THS3000 Series
Environmental
Characteristic Description
Enclosure IP 41 according to IEC60529
Temperature
Operating 0 °C to +40 °C (with battery)
0 °C to +50 °C (without battery)
Nonoperating 2Cto+6C
Humidity
Operating 10 °C to 30 °C, up to 95% relative humidity,
noncondensing
30 °C to 40 °C, up to 75% relative humidity,
noncondensing
40 °C to 50 °C, up to 45% relative humidity,
noncondensing
Nonoperating –20 °C to 60 °C, relative humidity, noncondensing
Altitude
Operating Up to 3,000 m (9,843 ft.)
Nonoperating Up to 12,000 m (39,370 ft.)
Vibration/Shock
Operating Vibration (Sinusoidal): 3 g max, according to
MIL-PRF-28800F, Class 2
Shock:30gmax,accordingtoMIL-PRF-28800F,Class2
Nonoperating Vibration (Random): 0.03 g2/Hz, according to
MIL-PRF-2800F, Class 2
Regulatory
Electromagnetic
Compatibility
EN 61326-1:2006, EN 61326-2-1:2006 for emission and
immunity
Safety UL61010-1:2004; CAN/CSA C22.2 No. 61010.1-04;
EN61010-1:2001, Pollution Degree 2; ANSI/ISA-82.02.01
Ordering Information
THS3000 Models
Model Description
THS3014 100 MHz, 2.5 GS/s, 4-channel handheld oscilloscope
THS3014-TK 100 MHz, 2.5 GS/s, 4-channel handheld oscilloscope with
travel kit
THS3024 200 MHz, 5 GS/s, 4-channel handheld oscilloscope
THS3024-TK 200 MHz, 5 GS/s, 4-channel handheld oscilloscope with
travel kit
All Models Include: THP0301-Y/B/M/G 300 MHz 10X Passive Probes, Lithium-ion
Battery with 7-hour battery life, Carrying Handle, Hanging Strap, USB-A to Mini
USB-B Cable for PC communication, Installation/Safety Manual, Documentation
CD (available in English, French, German, Spanish, Italian, Portuguese, Korean,
Japanese, Simplied Chinese, Traditional Chinese, and Russian) (063-4379-xx), AC
Power Adapter with Power Cord, ACHHS Soft-sided Carry Case (standard with base
model), OpenChoice®Desktop PC Communication Software, Calibration Certicate
Documenting Traceability to National Metrology Institute(s) and ISO9001 Quality
System Registration, Three-year Warranty.
TK Models Also Include: Hard-sided travel case, soft-sided probe case, 2 probe
replacement accessory kits.
Please specify power plug when ordering.
Recommended Accessories
Accessory Description
THSBAT Additional spare battery
THSCHG Battery charger (does not include AC power adapter)
ACHHS Instrument soft case
HCHHS Instrument hard case (standard with TK models)
376-0255-xx Versatile hanging hook
020-3085-xx Probe replacement accessory kit
119-7900-00 AC power adapter
Recommended Probes
Probe Description
A621 2000 A, 5 kHz to 50 kHz AC current probe/BNC
A622 100 A, 100 kHz AC/DC current probe/BNC
P5122 200 MHz passive 100X high-voltage probe
P5150 500 MHz passive 50X high-voltage probe*2
CT2 2.5 A, 200 MHz AC current probe
TCP303/TCPA300 150 A, 15 MHz AC/DC current probe/amplier
TCP305/TCPA300 50 A, 50 MHz AC/DC current probe/amplier
TCP312/TCPA300 30 A, 100 MHz, AC/DC current probe/amplier
TCP404XL/TCPA400 500 A, 2 MHz AC/DC current probe/amplier
*2The P5150 is fully compatible with THS oscilloscopes, but 50X vertical scaling is not offered.
International Power Plugs
Option Description
Opt. A0 North America power
Opt. A1 Universal Euro power
Opt. A2 United Kingdom power
Opt. A3 Australia power
Opt. A5 Switzerland power
Opt. A6 Japan power
Opt. A10 China power
Opt. A11 India power
Warranty
Three-year warranty covering all parts and labor, excluding probes.
www.tektronix.com 7
Data Sheet Contact Tektronix:
ASEAN / Australasia (65) 6356 3900
Austria 00800 2255 4835*
Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777
Belgium 00800 2255 4835*
Brazil +55(11)37597627
Canada 1 800 833 9200
Central East Europe and the Baltics +41526753777
Central Europe & Greece +41 52 675 3777
Denmark +4580881401
Finland +41526
75 3777
France 00800 2255 4835*
Germany 00800 2255 4835*
Hong Kong 400 820 5835
India 000 800 650 1835
Italy 00800 2255 4835*
Japan 81 (3) 6714 3010
Luxembourg +41526753777
Mexico, Central/South America & Caribbean 52 (55) 56 04 50 90
Middle East, Asia, and North Africa +41 52 675 3777
The Netherlands 00800 2255 4835*
Norway 800 16098
People’s Republic of China 400 820 5835
Poland +41 52 675 3777
Portugal 80 08 12370
Republic of Korea 001 800 8255 2835
Russia & CIS +7 (495) 7484900
South Africa +41526753777
Spain 00800 2255 4835*
Sweden 00800 2255 4835*
Switzerland 00800 2255 4835*
Taiwan 886 (2) 2722 9622
United Kingdom & Ireland 00800 2255 4835*
USA 1 800 833 9200
* European toll-free number. If not accessible, call: +41 52 675 3777
Updated 10 February 2011
For Further Information. Tektronix maintains a comprehensive, constantly expanding
collection of application notes, technical briefs and other resources to help engineers working
on the cutting edge of technology. Please visit www.tektronix.com
Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,
issued and pending. Information in this publication supersedes that in all previously published material.
Specication and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of
Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks
of their respective companies.
10 Nov 2011 3GW-27121-0
www.tektronix.com
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Tektronix:
ACHHS HCHHS THSBAT THS3014 THS3014-TK THS3024 THS3024-TK