HPR1XXC Series www.murata-ps.com 0.75 Watt Single Output DC/DC Converters FEATURES n Low Cost n Multiple Package Styles n Internal Input and Output n Filtering n Non-Conductive Case n n The HPR1XXC Series uses advanced circuit design and packaging technology to deliver superior reliability and performance. A 170kHz push-pull oscillator is used in the input stage. Beat-frequency oscillation problems are reduced when using the HPR1XXC Series with high frequency isolation amplifiers. Reduced parts count and high efficiency add to the reliability of the HPR1XXC Series. The high efficiency of the HPR1XXC Series means less internal power dissipation, as low as 190mW. High Output Power Density: 10 Watts/Inch3 With reduced heat dissipation the HPR1XXC Series can operate at higher temperatures with no degradation. In addition, the high efficiency of the HPR1XXC Series means the series is able to offer greater than 10 W/inch3 of output power density. Operation down to no load will not impact the reliability of the series, although a >1mA minimum load is needed to realize published specifications. Extended Temperature Range: -25C to +85C n Efficiency to 79% n RoHS Compliant The HPR1XXC Series provides the user a low cost converter without sacrificing reliability. The use of surface mounted devices and advanced manufacturing technologies make it possible to offer premium performance and low cost. As of October 2016, ONLY the following part numbers will be available: HPR100C; HPR105C; HPR107C; HPR116C; HPR117C; HPR118C SPECIFICATIONS All specifications are typical at TA = +25C nominal input voltage unless otherwise specified. PRODUCT SELECTION CHART Model Nominal Input Voltage Rated Output Voltage Rated Output Current VDC VDC mA 5 5 5 5 5 5 12 12 12 12 15 15 15 15 24 24 24 24 12 12 15 15 24 24 5 12 15 5 12 15 5 12 12 15 5 12 12 15 5 15 12 15 15 5 15 5 12 5 150 62 50 75 30 25 150 62 30 25 150 62 30 25 150 50 30 25 50 75 50 75 62 75 HPR100C HPR101C HPR102C HPR103C HPR104C HPR105C HPR106C HPR107C HPR110C HPR111C HPR112C HPR113C HPR116C HPR117C HPR118C HPR120C HPR122C HPR123C HPR108C HPR109C HPR114C HPR115C HPR119C HPR121C Input Current No Load 20 20 20 20 20 20 10 10 10 10 8 8 8 8 8 8 8 8 10 10 8 8 8 8 Rated Load mA 216 212 212 218 212 200 90 81 81 81 72 72 63 63 48 45 45 45 81 88 72 72 48 45 Reflected Ripple Current mAp-p 10 5 5 5 5 5 5 5 5 5 5 5 5 5 15 15 15 15 5 5 5 5 15 15 Efficiency Recommended Alternatives % 69 70 71 68 68 75 69 77 74 77 69 69 76 79 65 76 67 69 77 71 69 69 65 69 NMR100C / MER1S0505SC NMR101C / MER1S0512SC NMR102C / MER1S0515SC NMA0505SC / MEA1D0505SC NMA0512SC / MEA1D0512SC NMA0515SC / MEA1D0515SC NMR106C / MER1S1205SC NMR107C / MER1S1212SC NMA1212SC / MEA1D1212SC NMA1215SC / MEA1D1215SC MER1S1505SC MER1S1512SC MEA1D1512SC MEA1D1515SC MER1S2405SC MER1S2415SC MEA1D2412SC MEA1D2415SC NMR108C / MER1S1215SC NMA1205SC / MEA1D1205SC MER1S1515SC MEA1D1505SC MER1S2412SC MEA1D2405SC For full details go to www.murata-ps.com/rohs www.murata-ps.com/support TDC_HPR1xxC.E02 Page 1 of 4 HPR1XXC Series 0.75 Watt Single Output DC/DC Converters SPECIFICATIONS, ALL MODELS GENERAL OUTPUT INPUT Specifications are at TA = +25C nominal input voltage unless otherwise specified. PARAMETER CONDITIONS MIN TYP MAX UNITS INPUT Voltage Range 4.5 5 5.5 VDC 10.8 12 13.2 VDC 13.5 15 16.5 VDC 21.6 24 26.4 VDC Voltage Rise Time See Typical Performance Curves & Application Notes: "Capacitive Loading Effects on Start-Up of DC/DC Converters" OUTPUT Rated Power 750 mW Voltage Setpoint Accuracy Rated Load, Nominal VIN 5 % Ripple & Noise BW = DC to 10MHz 150 200 mVp-p BW =10Hz to 2MHz 30 40 mVrms Voltage (Over Input Voltage Range) 1mA to Rated Current, VOUT = 5V 4.75 7 VDC 1mA to Rated Current, VOUT = 12V 11.40 15 VDC 1mA to Rated Current, VOUT = 15V 14.25 18 VDC Temperature Coefficent .01 .05 %/ C REGULATION Load Regulation (All other modes) Rated Load to 1mA Load 3 % GENERAL ISOLATION Rated Voltage 750 VDC Test Voltage 60 Hz, 10 Seconds 750 Vrms Resistance 10 GW Capacitance 25 100 pF Leakage Current VISO= 240VAC, 60Hz 2 8.5 mArms Switching Frequency 170 kHz Frequency Change Over Line and Load 24 % Package Weight 3 g MTTF per MIL-HDBK-217, Rev. F* Circuit Stress Method Ground Benign TA = +25C 7.9 MHr Fixed Ground TA = +35C 1.9 MHr Naval Sheltered TA = +35C 1.2 MHr Airborne Uninhabited Fighter TA = +35C 300 kHr TEMPERATURE Specification -25 +25 +85 C Operation -40 +100 C Storage -40 +110 C SOLDERING INFORMATION The HPR1XXC devices are intended for wave soldering or manual soldering. They are not intended to be subject to surface mount processes under any circumstances. The normal wave soldering process can be used with these devices where the device is subjected to a maximum wave temperature of 260C for a period of no more than 10 seconds. Within this time and temperature range, the integrity of the device's plastic body will not be compromised and internal temperatures within the converter will not exceed 175C. Care should be taken to control manual soldering limits identical to that of wave soldering. www.murata-ps.com/support TDC_HPR1xxC.E02 Page 2 of 4 HPR1XXC Series 0.75 Watt Single Output DC/DC Converters TYPICAL PERFORMANCE CURVES Specifications are at TA = +25C nominal input voltage and nominal load. VOUT VS LOAD (5Vout Models) VOUT VS LOAD (5Vout Models) 5.7 5.4 5.5 5.2 VOUT VS LOAD (12Vout Models) 12.5 5.3 5.0 5.1 4.8 4.9 4.6 0 80 40 120 12.3 Vout Vout Vout 12.4 160 12.1 12.0 0 20 Output Current (mA) 12.3 15.3 12.1 15.1 12.0 14.9 10 20 20 30 40 80 60 16.0 15.5 15.0 14.5 14.0 0 20 40 60 13.5 80 Output Current each load (mA) Output Current each load (mA) EFFICIENCY VS LOAD OSCILLATION FREQUENCY VS TEMPERATURE 90 40 VOUT VS LOAD (15Vout Models) 16.5 15.5 12.2 0 0 Output Current each load (mA) Vout Vout Vout 11.9 80 15.7 12.4 0.2 0 0.4 0.6 0.8 1.0 Output Power each load (Watts) 220 Frequency (KHz) 75 Efficiency (%) 60 VOUT VS LOAD (15Vout Models) 15.9 12.5 60 45 30 15 0 40 Output Current each load (mA) VOUT VS LOAD (12Vout Models) 12.6 12.2 20 0 60 40 80 200 180 160 140 100 -30 0 % of Rated Load (%) 30 60 90 Temperature (C) SAFE OPERATING AREA LOAD CAPACITANCE vs INPUT RISE TIME (5 Vout models) 600 50 Total Load Capacitance (uF) Total Load Capacitance (uF) 500 400 300 SAFE OPERATING AREA 200 40 30 SAFE OPERATING AREA 20 10 100 0 0 0 5 10 15 20 25 30 35 Rise Time of Input Voltage (mS) 40 45 50 LOAD CAPACITANCE vs INPUT RISE TIME (12 Vout models) 90 Total Load Capacitance (uF) LOAD CAPACITANCE vs INPUT RISE TIME (15 Vout models) 60 5 10 15 20 25 30 35 40 45 50 Rise Time of Input Voltage (mS) NOTES: 1.) When operated within the SAFE OPERATING AREA as defined by the above curves, the output voltage of HPR1XXC devices is guaranteed to be within 95% of its steady-state value within 100 milliseconds after the input voltage has reached 95% of its steady-state value. 2.) For dual output models, total load capacitance is the sum of the capacitances on the plus and minus outputs. 80 70 60 50 SAFE OPERATING AREA 40 0 30 20 10 0 0 5 10 15 20 25 30 35 40 45 50 Rise Time of Input Voltage (mS) www.murata-ps.com/support TDC_HPR1xxC.E02 Page 3 of 4 HPR1XXC Series 0.75 Watt Single Output DC/DC Converters MECHANICAL "SIP" PACKAGE/PINOUT 0.240+0.010" (6.09+0.25) 0.77+0.010" (19.56+0.25) Notes: All dimensions are in inches (millimeters). GRID: 0.100 inches (2.54 millimeters) PIN PLACEMENT TOLERANCE: 0.015" MATERIAL: Lead material is phosphor bronze; lead finish is 100-300 microinches of matte tin over a nickel barrier layer of 5-40 microinches. RIGHT FRONT VIEW 0.397+0.010" (10.16+0.25) 1 2 4 *5 0.02+0.002" (0.51+0.05) 0.020+0.010" (0.51+0.25) 6 0.18+0.015" 0.140" MIN (3.56) (4.57+0.38) BOTTOM VIEW ABSOLUTE MAXIMUM RATINGS Internal Power Dissipation......................................... 450mW Short Circuit Duration................................................. Momentary SIDE VIEW 0.01+0.002" (0.25+0.05) 0.035+0.015" (0.89+0.38) *Common pin not present on single output models. PIN CONNECTIONS 1. +VIN 2. -VIN 4. -VOUT 5. COM* 6. +VOUT ORDERING INFORMATION HPR 1XX C Device Family HPR Indicates DC/DC Converter Model Number Selected from Table of Electrical Characteristics RoHS Compliant Version Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2017 Murata Power Solutions, Inc. www.murata-ps.com/support TDC_HPR1xxC.E02 Page 4 of 4