1
Simple Fiber Amplifier
E3X-SD
The Standard for Fiber Amplifiers with
Simple Operation and High Performance
Operation so simple that essentially anyone can use the
amplifier right way.
Immediately determine operation and amount of light with a
simple, bright display.
General-purpose capabilities to simply handle a broad range of
applications.
Ordering Information
Sensor I/O Connectors (Order Separately)
Accessories (Order Separately)
Amplifier Units
Digital Display and Direct Key Setting
Item Appearance
Connection
method
Ratings and
Specifications
Model
NPN
output
PNP
output
Standard
models
Pre-wired
---
E3X-SD11 E3X-SD41
Wire-saving
connector
E3X-SD6 E3X-SD8
Amplifier Unit Connectors (Order Separately)
Note: Stickers for Connectors are included as accessories.
Item Appear-
ance
Cable
length
No. of
conductors
Model
Master
Connector
2 m
3
E3X-CN11
Slave
Connector
1
E3X-CN12
Combining Amplifier Units and
Connectors
Amplifier Units Applicable Connectors (Order Separately)
Type NPN PNP +Master Connector Slave Connector
(Basically, Amplifier Units and Connectors are sold
separately)
Refer to the following tables when placing an order.
Standard
models E3X-SD6 E3X-SD8 E3X-CN11 (3-wire) E3X-CN12 (1-wire)
When Using 5 Amplifier Units
5 Amplifier Units +1 Master Connector + 4 Slave Connectors
Size Cable specifications Appearance Cable type Model
M8 Standard cable
2 m
Four-
conductor
cable
XS3F-M421-402-A
5 m XS3F-M421-405-A
2 m XS3F-M422-402-A
5 m XS3F-M422-405-A
Straight
connector
L-shaped
connector
Mounting Brackets
Appearance Applicable models Model Quantity
E3X-SD@E39-L143 1
End Plate
Appearance Model Quantity
PFP-M 1
E3X-SD
2
Ratings and Specifications
Amplifier Units
* Models with connectors have a dielectric strength of 500 VAC.
Amplifier Unit Connectors
Type Digital display and direct key setting
Standard models
Item Model E3X-SD@
Light source (wavelength) Red LED (620 nm)
Power supply voltage 12 to 24 VDC ±10%, ripple (p-p): 10% max.
Current consumption 960 mW max. (Power supply: 24 V, Current consumption: 40 mA max.)
Control output
Open-collector output (NPN or PNP)
Load power supply: 26.4 V max., Load current: 50 mA max. (Residual voltage: 1.5 V max.)
Light-ON/Dark-ON mode selector
Response time Operate or reset: 200 μs max.
Sensitivity adjustment UP/DOWN direct key setting, teaching
Protection circuits Power supply reverse polarity protection, output short-circuit protection, output reverse polarity protection
Timer function ON/OFF-delay timer: 10 ms (each fixed)
Mutual interference
prevention Up to 5 Amplifiers (optically synchronized)
Ambient illumination
Receiver side
Incandescent lamp: 10,000 lux max.
Sunlight: 20,000 lux max.
Ambient temperature range
Operating: Groups of 1 to 3 Amplifiers: 25°C to 55°C
Groups of 4 to 11 Amplifiers: 25°C to 50°C
Groups of 12 to 16 Amplifiers: 25°C to 45°C
Storage: 30°C to 70°C (with no icing or condensation)
Ambient humidity range Operating and storage: 35% to 85% (with no condensation)
Insulation resistance 20 MΩ. min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute (*)
Vibration resistance Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2, for 3 times each in X, Y and Z directions
Degree of protection IEC 60529 IP50 (with Protective Cover attached)
Connection method Pre-wired (standard cable length: 2 m), or connector
Weight (packed state) Pre-wired model: Approx. 100 g, Model with connector: Approx. 55 g
Material Case Polybutylene terephthalate (PBT)
Cover Polycarbonate
Accessories Instruction manual
Item Model E3X-CN11
Rated current 2.5 A
Rated voltage 50 V
Contact resistance
20 mΩ max. (20 mVDC max., 100 mA max.)
(The above figure is for connection to the Amplifier Unit and the adjacent Connector. It does not include the conductor resistance
of the cable.)
Number of insertions Destruction: 50 times (for connection to the Amplifier Unit and the adjacent Connector)
Material Housing Polybutylene terephthalate (PBT)
Contact Phosphor bronze/gold-plated nickel
Weight (packed state) Approx. 55 g
E3X-SD
3
Fiber Unit Overview
Through-beam model,
M4 screw
E32-T11N
Reflective model,
M6 screw
E32-D11N
280 mm
90 mm
New Head Shape
No snagging during maintenance.
Fiber flexibility prevents breaking.
L-shaped Attachment
Feature
1
Feature
2
10 mm*
8 mm*
*For M6 models.
Convenient design
accommodates two wrench sizes.
Allows quick tightening.
No snagging, no breaking:
Right-angle (L-shaped) Models
Reflective Fiber Units
Size: 15 × 10 × 3 mm
Flat and flexible fiber models are easy to mount
and will not break.
20 mm
Flat View
E32-D15ZR
Flexible fiber Conventional fiber
Cladding
Cores
No Breaking
Feature
A large number of ultrafine cores are all surrounded by cladding. As
a result, the fiber is flexible and can be bent without significantly
reducing the light intensity. This helps solve problems, such as
fiber being broken by getting caught on other objects.
Through-beam Fiber Units
Size: 15 × 8 × 3 mm
280 mm
110 mm 110 mm
Top View
E32-T15XR
Side View
E32-T15YR
Flat View
E32-T15ZR
E3X-SD
4
Sensing Distance
Through-beam Models (Unit: mm)
Model E3X-SD@
Type Standard models
Standard
models
Flexible
(new standard)
E32-T11R/E32-T12R/E32-T15XR/E32-TC200BR (B4R) 280
E32-T14LR/E32-T15YR/E32-T15ZR 110
E32-T21R/E32-T22R/E32-T222R/E32-T25XR/
E32-TC200FR (F4R) 60
E32-T24R/E32-T25YR/E32-T25ZR 30
Standard
E32-TC200/E32-T12/E32-T15X/E32-TC200B (B4) 400
E32-T14L/E32-T15Y/E32-T15Z 240
E32-TC200A 360
E32-TC200E/E32-T22/E32-T222/E32-T25X/E32-TC200F (F4) 100
E32-T24/E32-T25Y/E32-T25Z 90
Break resistant
E32-T11/E32-T12B/E32-T15XB 360
E32-T21/E32-T221B/E32-T22B 100
E32-T25XB 75
Fluorine coating E32-T11U 360
Special-
beam
models
Long distance,
high power
E32-T17L 14000
E32-TC200 + E39-F1 3000
E32-T11R + E39-F1 2100
E32-T11 + E39-F1 2000
E32-T14 1800
E32-T11L/E32-T12L 700
E32-T11L + E39-F2 500
E32-T11R + E39-F2 220
E32-T11 + E39-F2 360
E32-T21L/E32-T22L 200
Ultracompact,
ultrafine sleeve
E32-T223R 60
E32-T33-S5 20
E32-T333-S5 5
E32-T334-S5 2.5
Fine beam
(narrow vision field)
E32-T22S 1000
E32-T24S 700
Area sensing
E32-T16PR 450
E32-T16P 600
E32-T16JR 390
E32-T16J 520
E32-T16WR 690
E32-T16W 920
E32-T16 1500
E32-M21 300
Environment
resistive
models
Heat resistant
E32-T51 400
E32-T54 130
E32-T81R-S 180
E32-T61-S + E39-F2 390
E32-T61-S + E39-F1 3000
E32-T84S-S 700
E32-T61-S 300
Chemical
resistant
E32-T11F 1050
E32-T12F 1600
E32-T14F 200
E32-T51F 700
E32-T81F-S 350
Vacuum
resistant
E32-T51V 100
E32-T51V + E39-F1V 600
E32-T54V 65
E32-T54V + E39-F1V 390
E32-T84SV 250
For information on Fiber Units, refer to the E32 Series Fiber Sensor Best Selection (Cat. No. E354).
E3X-SD
5
Reflective Models (Unit: mm)
Model E3X-SD@
Type Standard models
Standard
models
Flexible
(new standard)
E32-D11R/E32-D12R/E32-D15XR/E32-DC200BR (B4R) 90
E32-D14LR 16
E32-D15YR/E32-D15ZR 20
E32-D211R/E32-D21R/E32-D22R/E32-D25XR/
E32-DC200FR (F4R) 15
E32-D24R 7
E32-D25YR/E32-D25ZR 4
Standard
E32-DC200/E32-D15X/E32-DC200B (B4) 150
E32-D12 120
E32-D14L 40
E32-D15Y/E32-D15Z 50
E32-D211/E32-DC200E/E32-D22/E32-D25X/
E32-DC200F (F4) 36
E32-D24 15
E32-D25Y/E32-D25Z 10
Break resistant
E32-D11/E32-D15XB 90
E32-D21B/E32-D221B 35
E32-D21/E32-D22B 15
E32-D25XB 25
Fluorine coating E32-D11U 90
Special-
beam
models
Long distance,
high power
E32-D16 40 to 400
E32-D11L 200
E32-D21L/E32-D22L 50
Ultracompact,
ultrafine sleeve
E32-D33 10
E32-D331 1.5
Coaxial, small spot
E32-CC200R 75
E32-CC200 150
E32-D32L 80
E32-C31/E32-D32 40
E32-C42 + E39-F3A Spot diameter of 0.1 to 0.6 mm at
6 to 15 mm.
E32-D32 + E39-F3A Spot diameter of 0.5 to 1 mm at
6 to 15 mm.
E32-C41 + E39-F3A-5 Spot diameter of 0.1 mm at 7 mm.
E32-C31 + E39-F3A-5 Spot diameter of 0.5 mm at 7 mm.
E32-C41 + E39-F3B
Spot diameter of 0.2 mm at 17 mm.
E32-C31 + E39-F3B
Spot diameter of 0.5 mm at 17 mm.
E32-C31 + E39-F3C Spot diameter of 4 mm max. at
0 to 20 mm.
Area sensing E32-D36P1 75
Retro-reflective E32-R21 + E39-R3 (provided) 10 to 250
E32-R16 + E39-R1 (provided) 150 to 1500
Convergent-
reflective
E32-L25/E32-L25A 3.3
E32-L24S 0 to 4
E32-L24L 2 to 6 (center 4)
E32-L25L 5.4 to 9 (center 7.2)
E32-L86 4 to 10
E32-L16 0 to 15
Environment
resistive
models
Heat resistant
E32-D51 120
E32-D81R/E32-D61 45
E32-D73 30
Chemical resistant E32-D12F 50
E32-D14F 20
For information on Fiber Units, refer to the E32 Series Fiber Sensor Best Selection (Cat. No. E354).
E3X-SD
6
I/O Circuit Diagrams
Note: Timing Charts for Timer Settings (T: Set Time)
Plug (Sensor I/O Connector)
Output
form Model
Output
transistor
operation mode
Timing charts Operation
selector Output circuit
NPN
Output
E3X-SD11
E3X-SD6
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
PNP
Output
E3X-SD41
E3X-SD8
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
ON delay OFF delay
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between brown and black leads)
Output
transistor
Load
(relay)
T
Black
Brown
Blue
Control output
Operation indicator
(orange)
Photo-
electric
Sensor
main
circuit
Load
12 to
24 VDC
1
4
3
M8 Connector Pin Arrangement
Note: Pin 2 is not used.
1
2 4
3
*
T
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between brown and black leads)
Output
transistor
Load
(relay)
T
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(relay)
T
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(relay)
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T
T
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T
T
Note: Pin 2 is not used.
Classification Wire color Connection pin Application
DC
Brown 1 Power supply (+V)
White 2 ---
Blue 3 Power supply (0 V)
Black 4 Output
2
4
1
3
1
2
3
4
Brown
White
Blue
Black
Wire color
Terminal number
XS3F-M421-402-A
XS3F-M421-405-A
XS3F-M422-402-A
XS3F-M422-405-A
E3X-SD
7
Nomenclature
Safety Precautions
This product is not designed or rated for
ensuring safety of persons either directly or
indirectly.
Do not use it for such purposes.
Do not exceed the rated voltage.
Excess voltage may result in malfunction or
fire.
Do not use an AC power supply.
Using an AC power supply may result in
rupturing.
High-temperature environments may result in
burn injury.
The following precautions must be observed to ensure safety.
1. Do not use the product in locations where flammable or
explosive gas is present.
2. Do not use the product in locations subject to splashing
water, oil, or chemicals, or in locations subject to steam.
3. Do not attempt to disassemble, repair, or modify the
product.
4. Do not apply voltage or current in excess of the rated
ranges.
5. Do not use the product in atmospheres or environments
that exceed product ratings.
6. Do not wire the product incorrectly, such as using incorrect
power supply polarity.
7. Connect the load properly.
8. Do not short-circuit both ends of the load.
9. Do not use the product if the case is damaged.
10. When disposing of the product, dispose of it as industrial
waste.
11. Do not use the product in locations subject to direct
sunlight.
12. The surface temperature of the product may rise as a
result of the ambient temperature, power supply, or other
usage conditions. Use caution when performing
maintenance and washing. Failure to do so may result in
burn injury.
Incident level
indicators
Lock lever
Operation Keys
Sensitivity adjustment
(UP/DOWN or teaching)
TEACH/RUN Mode Selector
Used to select TEACH or RUN mode.
Operation Indicator
Operation Selector
Use to switch between
Light-ON and Dark-ON
Timer switch
OFF/D: OFF-delay timer
ON/D: ON-delay timer
OFF: Timer function is OFF.
Amplifier Units
E3X-SD@
WARNING
Caution
Precautions for Safe Use
E3X-SD
8
Do not use the product in atmospheres or environments that
exceed product ratings.
Amplifier Units
Designing
Communications Hole
The hole on the side of the Amplifier Unit is a communications
hole for preventing mutual interference when Amplifier Units
are mounted side-by-side. The E3X-MC11 Mobile Console
(order separately) cannot be used.
If an excessive amount of light is received via the Sensor, the
mutual interference prevention function may not work. In this
case, make the appropriate adjustments using the sensitivity
adjuster.
The mutual interference prevention function will not operate
when the E3X-SD/NA is used side-by-side with E3X-DA-N
models.
Mounting
DIN Track Mounting/Removal
Mounting Amplifier Units
1. Mount the Amplifier Units one at a time onto the DIN track.
2. Slide the Amplifier Units together, line up the clips, and
press the Amplifier Units together until they click into place.
Removing Amplifier Units
Slide Amplifier Units away from each other, and remove from
the DIN track one at a time. (Do not attempt to remove
Amplifier Units from the DIN track without separating them
first.)
Fiber Connection and Disconnection
The E3X Amplifier Unit has a lock lever. Connect or
disconnect the fibers to or from the E3X Amplifier Unit using
the following procedures:
1. Connection
Open the Protective Cover, insert the fibers according to the
fiber insertion marks on the side of the Amplifier Unit, and
lower the lock lever.
2. Disconnection
Remove the Protective Cover and raise the lock lever to pull
out the fiber.
Note:To maintain the fiber properties, confirm that the lock is
released before removing the fiber.
3. Precautions for Fiber Connection/Disconnection
Be sure to lock or unlock the lock lever within an ambient
temperature range between 10°C and 40°C.
Operating Environment
Ambient Conditions
If dust or dirt adhere to the hole for optical communications, it
may prevent normal communications. Be sure to remove any
dust or dirt before using the Units.
Other
Protective Cover
Be sure to mount the Protective Cover before use.
Precautions for Correct Use
Note 1. The specifications for ambient temperature will vary according to the
number of Amplifier Units used together. For details, refer to Ratings
and Specifications.
2. Always turn OFF the power supply before mounting or removing
Amplifier Units.
Click into
place
Clip
Lock lever
Fiber Fiber insertion mark
10.7 mm
Insertion position
Locked Unlocked
Protective Cover
E3X-SD
9
Amplifier Units with Connectors
Mounting
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit
until it clicks into place.
2. Join Amplifier Units together as required after all the Master
and Slave Connectors have been inserted.
3. Attach the stickers (provided as accessories) to the sides of
Master and Slave Connectors that are not connected to
other Connectors.
Note: Attach the stickers to the sides with grooves.
Removing Connectors
1. Slide the slave Amplifier Unit for which the Connector is to
be removed away from the rest of the group.
2. After the Amplifier Unit has been separated, press down on
the lever on the Connector and remove it. (Do not attempt
to remove Connectors without separating them from other
Amplifier Units first.)
Mounting End Plate (PFP-M)
Depending on how it is mounted, an Amplifier Unit may move
during operation. In this case, use an End Plate.
Before mounting an End Plate, remove the clip from the
master Amplifier Unit using a nipper or similar tool.
The clip can also be removed using the following mechanism,
which is incorporated in the construction of the section
underneath the clip.
1. Insert the clip to be removed into the slit underneath the clip
on another Amplifier Unit.
2. Remove the clip by rotating the Amplifier Unit.
Pull Strengths for Connectors (Including Cables)
E3X-CN11: 30 N max.
E3X-CN12: 12 N max.
Insert
Sticker
Sticker
Remove
Lever
Press down
Clip
Rotate
E3X-SD
10
Dimensions (Unit: mm)
Amplifier Units
18
4.3
8
10.7
1010
3.4
22.4
4.4
13
64.364.3
16
10.75
16
8
10.7
3128.95
128.95
3128.95128.95
2.4
4
2.4
4
10.75
16
10 10
L
(16.5)
3.4
31.531.5
(16.5)
3.4
31.531.5
(9.4)
18
93.7593.75
1010
15
93.7593.75
13
12.430.4
64.364.3
Operation indicator
Two,
2.4 dia.
Two,
2.4 dia.
Hole for optical communications
Hole for optical communications
Center of DIN track
DIN track
(sold separately)
PFP-@N
Fiber Attachment mounted (E39-F9)
End Plate
(sold separately)
PFP-M
Mounting Bracket (E39-L143)
SUS304 stainless steel
Fiber Attachment mounted (E39-F9)
Two, M3
Mounting Holes
With Mounting Bracket Attached
Multiple connection diagram
DIN track mounting
Vinyl-insulated round cable
4 dia. cable / 3 conductors / Standard length: 2 m
(Conductor cross section: 0.2 mm2 (AWG24),
Insulator diameter: 1.1 mm)
Two, 3.2 dia. holes
Amplifier Units with Cables
E3X-SD11
E3X-SD41
The number of
expansion L (mm)
110
220
330
440
550
660
770
880
990
10 100
E3X-SD
11
Amplifier Units with Connectors
E3X-SD6
E3X-SD8
4.3
8
10.7
1010
3.4
22.4
4.4
13
64.364.3
16
16
8
10.7
3128.95
128.95
3128.95128.95
16
10 10
L
(16.5)
3.4
31.531.5
(16.5)
3.4
31.531.5
(9.4)
18
93.7593.75
1010
15
93.7593.75
13
12.430.4
64.364.3
Operation indicator
Two,
2.4 dia.
Two,
2.4 dia.
Hole for optical communications
Center of DIN track
DIN track
(sold separately)
PFP-@N
Fiber Attachment mounted (E39-F9)
End Plate
(sold separately)
PFP-M
Mounting Bracket (E39-L143)
SUS304 stainless steel
Fiber Attachment mounted (E39-F9)
Two, M3
Mounting Holes
With Mounting Bracket Attached
Multiple connection diagram
DIN track mounting
Two, 3.2 dia. holes
18
A dia.
12.95
Hole for optical communications
A dia.
12.95
* Cable Diameters
E3X-CN11 (3 conductors) 4.0-mm dia.
E3X-CN12 (1 conductor) 2.6-mm dia.
The number of
expansion L (mm)
110
220
330
440
550
660
770
880
990
10 100
E3X-SD
12
Amplifier Unit Connectors
Accessories (Order Separately)
For information on Fiber Units, refer to the E32 Series Fiber Sensor Best Selection (Cat. No. E353).
Master Connector
E3X-CN11
(7)
2,000
+50
0
*
* E3X-CN11: 4 dia.
4 dia.
cable / 3 conductors
3 conductors
/ Standard length: 2 m (Conductor cross section: 0.2 mm
2
(AWG24), Insulator diameter: 1.1 mm)
Edge of amplifier
Slave Connector
E3X-CN12
(7)
2,000 +50
0
*
* E3X-CN12: 2.6 dia.2.6 dia. cable / 1 conductor 1 conductor / Standard length: 2 m (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
Edge of amplifier
Mounting Brackets
E39-L143
Four, R1.7
7
3.4
1
3163
10 max. 710.3
7.3
5.3
(10.3) 2.5
34.8
22
16
26.8
3
Two, 3.2 dia.
3.4
1
Two, M3
16±0.1
Mounting Holes
Material: Stainless steel
(SUS304)
End Plates
PFP-M
50
11.5
10
M4 × 8
panhead screw
M4 spring washer
4.8
1.3
1.8
1.8
1
6.2 10
35.5
35.3
E3X-SD
13
Operating Procedure
E3X-SD@
A 7-segment display showing excess gain is provided in
addition to the orange operation indicator.
Use these when adjusting the light axis and setting the
sensitivity at setup.
The sensitivity can be set with the UP and DOWN Keys similar
to using an adjuster knob. The sensitivity can also be easily
set by using the following three teaching functions.
The sensitivity can be set to the maximum. This is the optimal
setting for resistance against the effects of dust.
Two points (one with the workpiece and the other without) are
detected, and the operating level is set to the midpoint.
Changes within a time are detected, and the operating level is
set to the midpoint between the maximum and the minimum
values of the changes. This setting is optimal for when the
workpieces cannot be stopped.
Display/indicator status (for L/ON) Excess gain Description
999%
(10 times)
110% min.
Stable incident
light
100%
90% to 110%
Unstable
incident light or
Unstable
interrupted light
0%
90% max.
Stable
interrupted light
Displays1
Operation indicator
Excess gain display
Operation description Switch/Key Display
Set the TEACH/RUN selector
switch to TEACH.
Press the UP Key for 3 s min.
Set the TEACH/RUN selector
switch to RUN (start of mea-
surement).
Operation description Switch/Key Display
Set the TEACH/RUN selector
switch to TEACH.
Press the UP Key with the
workpiece present.
Press the UP Key with the
workpiece not present.
Set the TEACH/RUN selector
switch to RUN (start of mea-
surement).
Operation description Switch/Key Display
Set the TEACH/RUN selector
switch to TEACH.
Press the UP Key.
Hold down the UP Key during
detection. Let the workpiece
pass while the key is held down.
Set the TEACH/RUN selector
switch to RUN (start of mea-
surement).
Sensitivity Setting2
2-1. Maximum Sensitivity Setting
RUN
TEACH
UP
RUN
TEACH
2-2. Teaching with/without a Workpiece
RUN
TEACH
UP
UP
RUN
TEACH
2-3. Automatic Teaching
RUN
TEACH
UP
UP
RUN
TEACH
MEMO
14
E3X-SD
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or
comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING
SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH
PURPOSES. Please refer to separate catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the
customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply
to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end
product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may
represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject
to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or
reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in
its entirety.
This document provides information mainly for selecting suitable models. Please read the Instruction sheet carefully for information that the user
must understand and accept before purchase, including information on warranty, limitations of liability, and precautions.
Authorized Distributor:
In the interest of product improvement,
specifications are subject to change without notice.
Cat. No. E388-E1-02 0410
© OMRON Corporation 2009 All Rights Reserved.
OMRON Corporation Industrial Automation Company
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
Contact: www.ia.omron.com
Tokyo, JAPAN
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
CSM_2_1_0114
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
E32-D24 E32-D32 E32-D61 E32-DC200E E32-T14L E32-CC200 E32-DC200 E32-TC200A E32-C42 E32-D11R
E32-D12 E32-D12F E32-D14L E32-D73 E32-DC200B E32-DC200B4 E32-DC200F E32-DC200F4 E32-G14
E32-L25 E32-L25A E32-L25L E32-R21 E32-T11L E32-T14 E32-T17L E32-T21R E32-T24S E32-TC200B E32-
TC200F E32-C41 E32-CC200R E32-T22B E3X-SD6 E3X-SD8 E3X-SD11 2M E3X-SD41 2M E32-R16 E32-D21R
E32-T22S