OUTLET SIDE
INLET SIDE
mm
(INCH)
UNIT:
UNIT : (INCH)
mm
(12.992 0.394)
330.0 10.0
(0.394)
10.0
(4- 0.138 0.008)
4- 3.5 0.2
(0.787 0.020)
20.0 0.5
(0.118 0.012)
3.0 0.3
(0.118 0.012)
3.0 0.3
(1.575 0.020)
(1.260 0.012)
(1.260 0.012)
(1.575 0.020)
40.0 0.5
40.0 0.5
32.0 0.3
32.0 0.3
LABEL
32.0
37.6
(1.480)
(1.260)
(1.480)
37.6
(1.260)
32.0
( 1.555)
( 1.555)
39.5
39.5
32.0
(1.260)
37.6
(1.480)
(1.260)
(1.480)
37.6
32.0
(4- 0.138) (4- 0.138)
4- 3.5 4- 3.5
Air Pressure
0
0.08
0.16
0.24
0.32
0.40
(mm H O)
2
2
(IN H O)
0.48
(CFM)
12.89.66.43.20
Air Flow
3
(M /MIN)
EFB0405/12/24XD
0 .08 .16 .32.24 .40
12.0
10.0
8.0
4.0
2.0
0
6.0
VH
HH
H
M
L
58
http://www.deltaww.com
EFB 40 x 40 x 20 MM SERIES
* Bearing Type
Ball Bearings
* Material
Impeller & Frame : Plastic (UL 94V-0)
* Lead Wires :
UL 1007 AWG #24 OR Equivalent
Red Wire Positive (+)
Black Wire Negative (-)
* Weight : 33g (1.16 oz)
* Rib Type Only
■ DIMENSIONS DRAWING
■ P & Q CURVE (AT RATED VOLTAGE) ■ MOUNTING PANEL CUTOUT
MODEL Rated
Voltage
Operating
Voltage
Range
Input
Current
Input
Power Speed Maximum
Air Flow
Maximum
Air Pressure Noise
PART NO. FUNCTION VDC VDC Amp Watt R.P.M. m3 /min CFM mmH2O IN H2O dB-A
EFB0405LD -R00 / -F00 5 4.5 to 5.5 0.10 0.50
5000 0.157 5.54 3.45 0.136 22.0EFB0412LD -R00 / -F00 12 7.0 to 13.8 0.05 0.60
EFB0424LD -R00 / -F00 24 14.0 to 27.6 0.04 0.96
EFB0405MD -R00 / -F00 5 4.5 to 5.5 0.15 0.75
6300 0.203 7.17 5.54 0.218 24.0EFB0412MD -R00 / -F00 12 7.0 to 13.8 0.06 0.72
EFB0424MD -R00 / -F00 24 14.0 to 27.6 0.05 1.20
EFB0405HD -R00 / -F00 5 4.5 to 5.5 0.25 1.25
7600 0.242 8.54 7.69 0.303 28.5EFB0412HD -R00 / -F00 12 7.0 to 13.8 0.08 0.96
EFB0424HD -R00 / -F00 24 14.0 to 27.6 0.06 1.44
EFB0405HHD -R00 / -F00 5 4.5 to 5.5 0.30 1.50
8200 0.267 9.43 9.00 0.354 30.5EFB0412HHD -R00 / -F00 12 7.0 to 13.8 0.10 1.20
EFB0424HHD -R00 / -F00 24 14.0 to 27.6 0.07 1.68
EFB0405VHD -R00 / -F00 5 4.5 to 5.5 0.32 1.60
9000 0.286 10.10 10.57 0.416 32.5
EFB0412VHD -R00 / -F00 12 7.0 to 13.8 0.12 1.44
EFB0424VHD -R00 / -F00 24 14.0 to 27.6 0.09 2.16
* Function type is optional.
* The max. air ow and the speed are measured in free air ; max. air pressure is measured at zero air ow.
* Noise is measured in anechoic chamber in free air, one meter from intake side.
* All readings are typical values at rated voltage.
* Specications are subject to change without notice.