IEC inlet filters
FN 329
Performance IEC inlet filter
Approvalsn Rated currents up to 6A
n Integrated earth line choke
n Optional medical versions (B type)
Typical applications
The FN 321 IEC inlet filter combines an
IEC inlet and mains filter with excellent filter
attenuation in a small form factor. The FN 329
performance power entry module offers
additional EMI suppression for the earth line.
Choosing the FN 329 compact power entry
module brings you the rapid availability of a
standard filter associated with the necessary
safety acceptances. Standard IEC connector
filters are a practical solution helping you to
pass EMI system approval in a short time. A
wide selection on current ratings, output
connections and low leakage versions for
medical applications helping you to select the
desired solution for your application.
n High conducted attenuation performance,
based on chokes with high saturation
resistance and excellent thermal behavior.
n Integrated earth line choke.
n Rear or front flange mounting.
n Optional low leakage current versions for
medical applications.
n Faston or solder terminal connections.
n Rated currents up to 6A.
n Custom-specific versions are available on
request.
n Portable electrical and electronic
equipment
n Small to medium-sized machines and
household equipment
n Single-phase power supplies, switch mode
power supplies
n Consumer goods
n Test and measurement equipment
n EDP and office equipment
n Medical equipment
n Rack mounting equipment
Features and benefits
Technical specifications
Maximum continuous operating voltage: 250VAC, 50/60Hz
Operating frequency: dc to 400Hz
Rated currents: 1 to 6A @ 50°C max.
High potential test voltage: P –> E 2000VAC for 2 sec (standard types)
P –> E 2500VAC for 2 sec (B types)
P –> N 760VAC for 2 sec
Protection category: IP40 according to IEC 60529
Temperature range (operation and storage): -25°C to +85°C (25/85/21)
Design corresponding to: UL 1283, CSA 22.2 No. 8 1986, EN 60939
Flammability corresponding to: UL 94V-2 or better
MTBF @ 40°C/230V (Mil-HB-217F): 600,000 hours
Typical electrical schematic
N
E
P
Line
L2
Cx R 2xL1 2xCy
N‘
E‘
P‘
Load
> Components > FN 329
Per CISPR 17; A = 50Ω/50Ω sym; B = 50Ω/50Ω asym; C = 0.1Ω/100Ω sym; D = 100Ω/0.1Ω sym
Typical filter attenuation
1A types 3 and 6A types
Filter selection table
FN 329-1-.. 1 (1.2) 560 6.3 0.4 47 3.3 -01 -05 55
FN 329-3-.. 3 (3.5) 560 1.25 0.4 47 3.3 -01 -05 55
FN 329-6-.. 6 (7.2) 560 0.48 0.4 47 3.3 -01 -05 55
FN 329B-1-.. 1 (1.2) 2 6.3 0.4 47 1000 -05 55
FN 329B-3-.. 3 (3.5) 2 1.25 0.4 47 1000 -05 55
FN 329B-6-.. 6 (7.2) 2 0.48 0.4 47 1000 -05 55
* Max. leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level.
Filter Rated current Leakage current* Inductance Capacitance Resistance Output connections Weight
@ 40°C (25°C) @ 230VAC/50Hz L1 L2 Cx Cy R
[A] [µA] [mH] [mH] [nF] [nF] [kΩ] [g]
Product selector
FN 329x-yy-..
01: Solder lug
05: Faston 6.3 x 0.8mm
1 to 6: Rated current
Blank: Standard version
B: Medical version (with bleed resistor and without Y2-capacitor)
For example: FN 329-1-01, FN 329-3-05, FN 329B-6-05
> Components > FN 329
Your local partner: To find your local partner within Schaffner’s global network, please go to www.schaffner.com January 2007
All dimensions in mm; 1 inch = 25.4mm
Tolerances according: ISO 2768 / EN 22768
FN 329 FN 329 Tolerances
Connection style -01 Connection style -05
Dimensions
A 51.5 51.5 ±0.5
B 26 26 ±0.3
C 40 40 ±0.2
D 46.6 46.6 ±0.3
E 27.9 27.9 +0.5
F 5.5 5.5 ±0.3
G 20.1 20.1
H Ø3.3 Ø3.3
I 11.4 13.4
J 10.9 10.9 ±0.5
M R ≤ 3 R ≤ 3
N 21.5 21.5 ±0.2
P 28.5 28.5 ±0.2
R M3 M3
S 90° 90°
Mechanical data
Connection style -01 Connection style -05
Panel cut out
A
C
B
E
G
S
FDI
J
H
C
PR
M
N
A
C
B
E
G
S
FDI
6.3 x 0.8
J
H