1
Products and specifications subject to change without notice.
Consult factory for application assistance.
204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-25
SOLID STATE RELAYS
INPUT SPECIFICATIONS:
84132000 84132100
84132010 84132110
84132400(9) 84132500
Model Number 84132410(9) 84132510 Units
Parameter
Control Voltage 4-15 4-15 VDC
Drop Out Voltage 1.0 1.0 VDC
Maximum Input Current (1) 32 32 mA
Maximum Turn-On Time 8.33 0.1 ms
Maximum Turn-Off Time 8.33 8.33 ms
Type Zero Crossing Random Turn-On
Wire Size
OUTPUT SPECIFICATIONS:
Model Number
84132000 84132010 84132400 84132410
84132100 84132110 84132500 84132510
Parameter Units
Line Voltage 24-280 24-280 36-530 36-530 Vrms
Peak Off-State Voltage (2) 600 600 800 800 Vpeak
Maximum Off-State Leakage (3) 0.1 0.1 0.1 0.1 mArms
Static Off-State dv/dt 250 250 250 250 V/Sec
Minimum On-State Current 0.1 0.1 0.1 0.1 Arms
Maximum On-State Current (4) 12 20 12 20 Arms
Maximum 1-Cycle Surge (5) 120 200 120 200 Apeak
Maximum 1-Second Surge (6) 36 60 36 60 Apeak
Peak On-State Voltage Drop (7) 1.65 1.55 1.65 1.55 Vpeak
l2t (60 Hz, Half-Cycle) 50 50 50 50 A2sec
Rjb 3.0 2.2 3.0 2.2 °C/W
Notes:
(1) At 15Vdc.
(2) Do not apply continuously for over 1 minute.
(3) At maximum rated voltage.
(4) Mounted in free air, Ta = 45°C.
(5) Non-repetitive 60 Hz, Resistive load, Ta = 25°C.
(6) Non-repetitive 50 or 60 Hz, Resistive load, Ta = 25°C.
(7) At maximum rated current.
(8) Limited to 1 mA for 1 second, Ta = 25°C.
(9) Input current is 63 mA Max.
GZ SERIES SSR
GENERAL SPECIFICATIONS:
Parameter All Devices
Operating Temperature Range -20 to 80°C
Storage Temperature Range -40 to 100°C
Input to Output Isolation Voltage (8) 4000 Vrms
I/O to Ground Isolation Voltage (8) 2500 Vrms
Capacitance (Input to Output) 8 pF
Line Frequency Range 47 to 63 Hz