Electrical Characteristics
(VIN = 5.5V, CIN = 1μF, COUT = 1μF, TA = 25°C, unless otherwise specified)
Parameter Symbol Test Conditions Min Typ Max Unit
Inpu t Volta ge Range V IN 2 -- 6 V
Output Voltage Accuracy ΔVOUT I
L = 1mA -2 -- +2 %
Maximum Output Current IMAX V
IN = VOUT + 0.6V, VIN ≥ 3.6V 100 -- -- mA
Current Limit ILIM I
L = 100mA 150 250 -- mA
No Load -- 4 7 μA
GND Pin Cu rrent IG IOUT = 100mA 4 10 μA
IOUT = 1 mA, VIN ≥ 3.6V -- 4 10
IOUT = 50 mA, VIN ≥ 3.6V -- 200 300 Dropout Voltage VDROP
IOUT = 100mA, VIN ≥ 3.6V -- 450 600
mV
Line Regulation ΔVLINE VIN = (VOUT + 0.3V) to 6V,
VIN ≥ 3.6V , IOUT = 1mA -0.2 -- +0.2 %/V
Load Re gulation ΔVLOAD I
LOUT = 0mA to 100mA -- 0.01 0.04 %/mA
Output Noise eNO BW = 10 0 Hz to 50 kHz
COUT = 10μF -- 250 -- μV
Ripple Re jec tion PSRR F = 1kHz, COUT = 1μF -- 30 -- dB
S tandby
Current RT 9 169/H (SOT-23-5) EN = V IN or E N = 0 -- 0.1 1 μA
Logic High VIL 0.6 -- --
EN/EN
Threshold Logic Low VIH -- -- 2 V
Thermal Shutdown Protection 125 -- -- °C
Application Information
A 1μF (or larger) capacitor is recommended between VOUT and GND for stability. The part may oscillate without the
ca pacitor. Any type of ca pacitor can be used, but not Aluminum electrolytes when operating below –25°C. The ca pacitance
may be increased without li mit.
A 1μF ca pacitor (or larger) should be pla ced between VIN to GND.
Note 1. Stresses listed as the above "Absolute Maximum Ratings" may cause permanent damage to the device. These are for
stress ratings. Functional operation of the device at these or any other conditions beyond those indicated in the
operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended
periods may remain possibility to affect device reliability.
Note 2. θJA is measured in the natural convection at TA = 25°C on a low effective thermal conductivity test board of
JEDEC 51-3 thermal measurement standard.
Note 3. Devices are ESD sensitive. Handling precaution is highly recommended.