Universal AC input / Full range
Built-in active PFC function
High efficiency up to 90%
Protections: Short circuit / Overload / Over voltage
Protections: Over temperature (optional)
Built-in remote ON-OFF control
5 years warranty
Withstand 300VAC surge input for 5 seconds
Cooling by free air convection
1U low profile 38mm
No load power consumption<0.5W
All using 105 long life electrolytic capacitors
SPECIFICATION
HRP-100-3.3 HRP-100-5 HRP-100-7.5 HRP-100-12 HRP-100-15 HRP-100-24 HRP-100-36 HRP-100-48
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
RIPPLE&NOISE(max.) Note.2
OUTPUT VOLTAGE ADJ.RANGE
VOLTAGETOLERANCE Note.3
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE Note.5
FREQUENCY RANGE
POWERFACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
OVERTEMPERATURE
SAFETY STANDARDS
HARMONICCURRENT
EMICONDUCTION&RADIATION
SAFETY &
EMSIMMUNITY
EMC
(Note4)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
WORKINGTEMP.
REMOTECONTROL
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
PROTECTION
ACCURRENT (Typ.)
3.3V 5V 7.5V 12V 15V 24V 36V 48V
20A 17A 13.5A 8.5A 7A 4.5A 2.9A 2.2A
0~20A 0~17A 0~13.5A 0~8.5A 0~7A 0~4.5A 0~2.9A 0~2.2A
66W 85W 101.3W 102W 105W 108W 104.4W 105.6W
80mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p
3.1~3.8V 4.75~5.8V 7.1~9V 11.4~13.8V 14.25~18V 22.8~28.8V 34.2~39.6V 45.6~55.2V
0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2%
2.0% 2.0% 1.5% 0.8% 0.8% 0.5% 0.5% 0.5%
2500ms,100ms/230VAC 2500ms,100ms/115VACatfullload
50ms/230VAC20ms/115VACatfullload
85~264VAC120~370VDC
47~63Hz
PF>0.95/230VACPF>0.98/115VACatfullload
78% 83%
6~7V 9.4~10.9V 14.4~16.8V 18.8~21.8V 30~34.8V 41.4~48.6V 57.6~67.2V
84% 87.5% 88% 88.5% 89% 90%
1.2A/115VAC0.6A/230VAC
35A/115VAC65A/230VAC
<1mA /240VAC
105~135%ratedoutputpower
Protectiontype:ConstantcurrentlimitingforVo=50~100%ofratedvoltage,recoversautomaticallyafterfaultconditionisremoved
3.96~4.62V
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
Protectiontype: o/pvoltage,recoversautomaticallyaftertemperaturegoesdownShutdown
UL60950-1, TUVEN60950-1approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2, heavyindustrylevel,criteria A
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
-40~+60 (Refertooutputloadderatingcurve)
RC+/RC-:0~0.8V=poweron;4~10V=poweroff
20~90%RHnon-condensing
-40~+85 ,10~95%RH
0.04%/ (0~50
10~500Hz,5G10min./1cycle,60min.eachalongX, Y,Zaxes
295.7Khrsmin.MIL-HDBK-217F(25 )
159*97*38mm(L*W*H)
FileName:HRP-100-SPEC2010-11-29
Features :
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
HRP-100 series
100WSingleOutputwithPFCFunction
FUNCTION
0.38Kg;24pcs/10.1Kg/0.76CUFT
+2.5,-3.5% 2.5% 2.5% 1.5% 1.5% 1.5% 1.5% 1.5%
90 (3.3V~7.5V),85 (12V~48V)(TSW1:detectonheatsinkQ101ofpowertransistor)(optional)
http://store.iiic.cc/
MechanicalSpecification CaseNo.901IUnit:mm
TerminalPinNo. Assignment
PinNo. PinNo.
1
2
4,5
3
6,7
Assignment Assignment
DCOUTPUT -V
DCOUTPUT +V
FG
AC/L
AC/N
4.5
9
152.5
7
1506.5
18.5
78
97
84.5
65
3.5
24
159
22 117
9
28.5
3.5
3.5
18
3.5
38
6-M3(BothSides)L=6
2-M3L=4
DETECTION
CIRCUIT
SVR1
10max.
1
2
3
4
5
6
7
9.5
8.2
CN100
II
RemoteON/OFF(CN100):JST B-XHorequivalent
PinNo.
1
2
Assignment
RC+
RC-
MatingHousing
JST XHP JST SXH-001T
orequivalent orequivalent
Terminal
12
20
40
60
80
100
100WSingleOutputwithPFCFunction
FileName:HRP-100-SPEC2010-11-29
DeratingCurve OutputDeratingVSInputVoltage
AMBIENTTEMPERATURE( ) INPUTVOLTAGE(V)60Hz
Ta=25
85 100 125 135 155 264
100
90
80
70
60
50
40
LOAD(%)
LOAD(%)
-40 0 10 20 30 40 50 60 70 (HORIZONTAL)
O.L.P.
O.T.P.
EMI INRUSH
ACTIVE
FILTER CURRENT
LIMITING
RECTIFIERS
&
PFC
I/P
FG
PWMPFC
POWER
SWITCHING FILTER
&
RECTIFIERS +V
CONTROLCONTROL
O.V.P.
REMOTE
CONTROL
-V
RC+
RC-
HRP - 100 s e r i es
BlockDiagram
http://store.iiic.cc/