Keysight Technologies
InniiVision 2000 X-Series Oscilloscopes
Data Sheet
Breakthrough technology for budget conscious customers
Overview of the Keysight InniiVision X-Series oscilloscopes
InniiVision
2000 X-Series
InniiVision
3000 X-Series
InniiVision
4000 X-Series
Analog channels 2 and 4 2 and 4 2 and 4
Bandwidth (upgradable) 70, 100, 200 MHz 100, 200, 350, 500 MHz, 1 GHz 200, 350, 500 MHz, 1 GHz, 1.5 GHz
Digital channels 8 (MSO models or upgrade)* 16 (MSO models or upgrade) 16 (MSO models or upgrade)
Maximum sample rate 2 GSa/s 5 GSa/s (1-GHz models)
4 GSa/s (100-500 MHz models)
5 GSa/s
Maximum memory depth 100 kpts/channel (standard)
1 Mpt/channel (optional)
2 Mpts (standard), 4 Mpts (op-
tion)
4 Mpts (standard)
Waveform update rate > 50,000 waveforms per
second
> 1,000,000 waveforms per
second
> 1,000,000 waveforms per second
Display 8.5-inch display 8.5-inch display 12.1-inch capacitive touch display
InniiScan Zone touch trigger No No Standard
WaveGen 20-MHz function/
arbitrary waveform generator
Single-channel function only
(option)
Single-channel AWG (option) Dual-channel AWG (option)
Integrated digital voltmeter Yes (option) Yes (option) Yes (option)
Search and navigate Yes (serial) Yes Yes
Serial protocol analysis Yes (optional: CAN, LIN, I²C,
SPI, RS232/UART)*
Yes (optional: ARINC 429, CAN
FlexRay, I2C, I2S, LIN, MIL-
STD-1553, SPI, UART/RS232)
Yes (optional: ARINC 429, CAN,
FlexRay, I2C, I2S, LIN, MIL-STD-1553,
SPI, UART/RS232, USB 2.0)
Segmented memory Yes (option) Yes (option) Standard
Mask/limit testing Yes (option) Yes (option) Yes (option)
Power analysis No Yes (option) Yes (option)
USB 2.0 signal quality test No No Yes (option)
HDTV analysis No Yes (option) Yes (option)
Advanced waveform math No Yes (option) Standard
Connectivity Standard USB 2.0 (LAN/Video
option) (GPIB option)
Standard USB2.0 (LAN/Video
option) (GPIB option)
Standard USB2.0, LAN, video out
(GPIB option)
* The digital channels and serial protocol analysis cannot be used simultaneously on 2000 X-Series.
Need bigger display and state-of-the-art usability?
See the InniiVision 4000 X-Series, which redenes the
oscilloscope experience.
Industry’s rst 12.1-inch capacitive touch display
InniiScan Zone touch trigger capability
200 MHz - 1.5 GHz DSO and MSO models
1,000,000 wfms/sec
Standard segmented memory
Fully upgradable 5 instrument in 1
Digital channels (MSO)
Protocol analysis including USB 2.0
20 MHz Dual-channel WaveGen with arbitrary waveform
and modulation support
Digital voltmeter (DVM)
Application analysis including power analysis, Xilinx FPGA,
and USB 2.0 signal quality
N8900A Inniium Ofine software support
Standard LAN, USB, and video out connectivity See www.keysight.com/nd/4000X-Series for more details.
2 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
With more scope, you can:
See more of your signal more of the time with the
largest screen in its class, the deepest memory
and the fastest waveform update rates
Do more with the power of 5 instruments in 1:
oscilloscope, logic timing analyzer, WaveGen
built-in 20 MHz function generator (optional), se-
rial protocol triggering and decode (optional), and
digital voltmeter (optional)
Get more investment protection with the classes
only fully upgradable scope, including memory
and bandwidth, and a standard 5 year warranty.*
The InniiVision 2000 X-Series offers entry-level price
points to t your budget with superior performance and
optional capabilities that are not available in any other
oscilloscope in its class. This Keysight Technologies, Inc.
breakthrough technology delivers more scope for the
same budget.
*5-year warranty applies to all orders on or after 1/1/2013.
More scope
3 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
How does Keysight do that?
Keysight-designed MegaZoom IV custom ASIC technology
combines the capabilities of an oscilloscope, logic analyzer,
and WaveGen built-in function generator in a compact form
factor at an affordable price. 4th generation MegaZoom
technology enables the industry’s fastest waveform update
rate with responsive deep memory acquisitions.
Largest display
Engineering for the best signal visibility starts with the
largest display. Our 8.5-inch WVGA display offers 50%
more viewing area with 3.5 times the resolution (WVGA
800 x 480 versus 7-inch WQVGA 480 x 234).
Fastest update rate
With Keysight-designed MegaZoom IV custom ASIC
technology, the InniiVision 2000 X-Series family delivers
up to 50,000 waveforms per second. With this speed you
can see signal detail and infrequent anomalies more of the
time.
Notice that the Keysight 2000 X-Series allows you to see more of your signals, and captures the infrequent glitch that you are unable to
see on other oscilloscopes in this class.
See more of your signal, more of the time
4 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
Industrys rst economy-class mixed signal
oscilloscope (MSO)
The 2000 X-Series is the rst instrument in its class to of-
fer an integrated logic timing analyzer. Digital content is
everywhere in today’s designs and with an additional 8
integrated digital timing channels, you now have up to
12 channels of time-correlated triggering, acquisition
and viewing on the same instrument. Buy a 2 or 4 chan-
nel DSO and at any time, upgrade it yourself to a MSO
with a license to turn on those integrated 8 digital timing
channels.
Industrys rst WaveGen built-in 20 MHz function
generator with a modulation capability
An industry rst, the 2000 X-Series offers an integrated
20 MHz function generator, now available with the signal
modulation capability. Ideal for educational or design labs
where bench space and budget are at a premium, the
integrated function generator provides stimulus output
of sine, square, ramp, pulse, DC and noise waveforms to
your device under test. No need to buy a separate function
generator when you can get one integrated in your new
oscilloscope. Turn on WaveGen at any time by ordering the
DSOX2WAVEGEN option and install the license yourself.
Best-in-class oscilloscope
The InniiVision 2000 X-Series features Keysight’s patented
MegaZoom IV smart memory technology that is always
enabled and always responsive providing the industry’s fast-
est update rate at up to 50,000 waveforms per second, with
no compromise if you turn on measurements or add digital
channels. In addition, the 2000 X-Series offers 23 automated
measurements such as voltage, time, and frequency as well
as ve waveform math functions including add, subtract,
multiply, divide, and FFT.
Do more with the power of 5 instruments in 1
Hardware-based serial protocol decode and
triggering
Embedded serial triggering and analysis (I²C, SPI)
Computer serial triggering and analysis
(RS232/422/485/UART)
Automotive and industrial serial triggering and
analysis (CAN,LIN)
Keysight’s InniiVision Series oscilloscopes are the indus-
try’s rst scopes to use hardware-based serial protocol
decoding. Other vendors’ oscilloscopes use software
post-processing techniques that slow down both wave-
form and decode update rate. That’s especially true when
using deep memory, which is often required to capture
multiple packetized serial bus signals. Faster decoding
with hardware-based technology enhances scope us-
ability and, more importantly, the probability of capturing
infrequent serial communication errors. After capturing a
serial bus communication, you can easily perform a search-
and-navigation operation based on specic criteria of your
interest. Sometimes it may be necessary to correlate data
from one serial bus to another. You can turn on the serial
trigger and decode or digital channels simultaneously on the
2000 X-Series.
Integrated digital voltmeter
An industry rst, the 2000 X-Series offers an integrated
3-digit voltmeter (DVM) and 5-digit frequency counter inside
the oscilloscopes. The voltmeter operates through the same
probes as the oscilloscope channels, however, the mea-
surements are de-coupled from the oscilloscope triggering
system so that both the DVM and triggered oscilloscope
measurements can be made with the same connection. The
voltmeter results are always displayed, keeping these quick
characterization measurements at your ngertips. Turn on
DVM at any time by ordering the DSOXDVM option.
5 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
Upgradability:
Project needs change, but traditional oscilloscopes are xed
– you get what you pay for at the time of purchase. With the
2000 X-Series, your investment is protected. If you need
more bandwidth (up to 200 MHz), digital channels, memory,
WaveGen, integrated digital voltmeter, or measurement
applications in the future, you can easily add them all after
the fact.
Add at the time of your purchase or upgrade later:
Bandwidth
Digital channels (MSO)
Memory
WaveGen built-in 20 MHz function generator
Integrated digital voltmeter (DVM)
Serial protocol analysis
Measurement applications
Mask testing
Segmented memory
Educators’ lab kit
Mask testing
Whether performing pass/fail tests to specied standards
in manufacturing or testing for infrequent signal anoma-
lies in R&D debug, the mask test option can be a valuable
productivity tool. The 2000 X-Series features hardware-
based mask testing and can perform up to 50,000 tests
per second.
Segmented memory
When capturing low-duty cycle pulses or data bursts,
you can use segmented memory acquisition to optimize
acquisition memory. Segmented memory acquisition lets
you selectively capture and store important segments of
signals without capturing unimportant signal idle/dead-
time. Segmented memory acquisition is ideal for applica-
tions including packetized serial pulses, pulsed laser, radar
bursts and high-energy physics experiments. Up to 250
segments can be captured on the 2000 X-Series models
with a minimum re-arm time under 19 µs.
Get more investment protection with the industrys only fully upgradable
oscilloscope
See page 21 for more information on upgradable products.
30-day trial license
The 2000 X-Series comes with a one-time 30-day all-
optional-features trial license. You can choose to start
the 30-day trial at any time. In addition you can redeem
individual optional feature 30-day trial licenses at any
time by visiting www.keysight.com/nd/30daytrial. This
enables you to receive in effect 60 days of trial license of
each optional feature.
6 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
Reference waveforms
Store up to two waveforms in the scope’s non-volatile
reference waveform memory locations. Compare these
reference waveforms with live waveforms, and perform
post analysis and measurements of stored data. You can
also store waveform data on a removable USB memory
device that can be recalled back into one of the available
two reference memories of the scope for full waveform
measurement and analysis. Save and/or transfer wave-
forms as XY data pairs in a comma-separated values for-
mat (*.csv) for PC analysis. Save screen images to a PC for
documentation purposes in a variety of formats including:
8-bit bitmaps (*.bmp), 24-bit bitmaps (*.bmp), and PNG
24-bit images (*.png).
Localized GUI and help
Operate the scope in the language most familiar to you.
The graphical user interface, built-in help system, front
panel overlays, and user’s manual are available in 13
languages. Choose from: English, Japanese, simplied
Chinese, traditional Chinese, Korean, German, French,
Spanish, Russian, Portuguese, Thai, Polish and Italian.
During operation, access the built-in help system just by
pressing and holding any button.
Probe solutions
Get the most out of your 2000 X-Series scope, by us-
ing the right probes and accessories for your application.
Keysight offers a complete family of innovative probes and
accessories for the InniiVision 2000 X-Series scopes.
For the most up-to-date and complete information about
Keysight’s probes and accessories, please visit our Web site
at www.keysight.com/nd/scope_probes.
Other productivity tools
Autoscale
Quickly display any active signals and automatically set the
vertical, horizontal and trigger controls for optimal viewing
with the press of the autoscale button. (This feature can
be disabled or enabled for the education environment via a
USB thumb drive le with a SCPI remote command).
7 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
Other productivity tools (continued)
Secure erase
The secure erase feature comes standard with all
InniiVision X-Series models. At the press of a button,
internal nonvolatile memory is clear of all setup, reference
waveforms, and user preferences, ensuring the highest
level of security in compliance with National Industrial
Security Program Operation Manual (NISPOM) Chapter 8
requirements.
Virtual front panel
In addition to the traditional VNC virtual front panel remote
operation through your favorite PC Web browser, the
InniiVision X-Series supports remote oscilloscope control
from your tablet devices. The tablet virtual front panel looks
and acts as the real front panel on the oscilloscope. Control
the setting, save/recall data, get image, and more.
Connectivity and LXI compatibility
Built-in USB host (one front, one back) and USB device
ports make PC connectivity easy. Operate the scope from
your PC and save and recall stored waveforms as well as
set-up les via LAN. An optional LAN/VGA module gives
you network connectivity and complete LXI class C support
as well as the ability to connect to an external monitor. An
optional GPIB module is also available. Only one module
may be used at a time.
34840B BenchVue lets you visualize the 3000 X-Series
and multiple measurements simultaneously. Save time with
the ability to export measurement data to Excel, Word and
MATLAB in three clicks. Monitor and control your 3000 X-
Series with a mobile device from anywhere. Learn more at
www.keysight.com/nd/BenchVue.
View Scope enables simple and free time-correlated me
asurements between a 2000 X-Series oscilloscope and a
Keysight 16900, 16800, 1690 or 1680 Series logic analyzer.
8 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
Other productivity tools (continued)
Inniium Ofine oscilloscope analysis software
(N8900A)
Keysight’s Inniium Ofine PC-based analysis oscilloscope
software allows you to do additional signal viewing, analysis
and documentation tasks away from your scope. Capture
waveforms on your scope, save to a le, and recall the
waveforms into Inniium Ofine. The application supports a
variety of popular waveform formats from multiple
oscilloscope vendors and includes the following features: View and analyze away from your scope and target system
Navigate
Pan and zoom to anywhere in the data record. Navi-
gate in time, or between bookmarks.
View
Up to 8 waveforms simultaneously, 1, 2, or 4 grids
(stacked, side by side, custom layout, zoom)
Measurements
Over 50 automated measurements
View up to 20 simultaneously
User-customizable result window (size, position, information)
X & Y markers with dynamic delta values
Analyze
20 math operators including FFT and lters
Up to four independent/cascaded math functions
Measurement histogram
View windows
Analog, math, spectral, measurement results
(simultaneous, tabbed, or undocked)
Documentation
Right-click to copy
Up to 100 bookmarks
Annotated axis values
Markers with dynamic delta value updates when moved
One step save/load setup and all waveforms
Analysis upgrades (optional)
Protocol decode for I2C/SPI, RS232/UART, CAN/ LIN/
FlexRay, SATA, 8B/10B, digRF v4, JTAG , MIPI D-Phy,
SVID, Ethernet 10G KR, PCIe 1, 2, 3, USB 2, 3, HSIC
Jitter analysis
Serial data analysis
Use familiar scope controls to quickly navigate and zoom in to
any event of interest.
Add bookmarks and call outs to produce friendly and useful
documentation.
9 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
Other productivity tools (continued)
Keysight Spectrum Visualizer (ASV) software
This PC-based software package connects to the scope
via USB or ethernet connection and uses the Keysight
I/O libraries to communicate. It provides advanced FFT
frequency domain analysis at a cost-effective price as well
as spectrum and spectrogram analysis with an intuitive user
interface that RF engineers are familiar with.
Tools include:
Spectrum measurements
Power (dBm) vs. frequency
Horizontal (x-axis): Specify center frequency and
frequency span, or start and stop frequencies
Vertical (y-axis): Specify reference level (dBm) and
scale (dB/div)
Settable resolution bandwidth
Flat top, Gaussian, or Hanning windows applied to the
time domain data for the FFT analysis
Marker to peak amplitude, and marker to center
frequency.
Marker peak search can be enabled for time-varying
signals
Multiple marker, with delta X and delta Y readouts
Acquisition and display modes
Free Run (continuous ), Triggered, Stop, Single, Preset
Triggered mode: specify trigger power level (dBm),
single or continuous sweep
Enable/disable y-axis label
Enable/disable main trace display
Max hold display mode
Gated Measurements
Multiple viewing options
- Spectrogram
- waterfall
- 3D
Changeable scaling settings on main window
Local language support
Multiple oscilloscopes can be congured to allow user
to rapidly switch between multiple instruments
Arbitrary waveform generator source control
20 MHz sine wave
10 MHz square wave
Pulsed waveform
WaveGen source settings can be altered while ASV
is running for interactive signal source and analysis
capability
Waterfall View for ASV Spectrogram Measurement
Close-Up Detail on Frequency Shift Keying (FSK) Characteristics
with the ASV Spectrogram Measurement
10 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
Quickly and easily set up or upgrade a
teaching lab
Teach your students what an oscilloscope is and how to
perform basic measurements with the Educator’s Oscil-
loscope Training Kit (DSOXEDK). It includes training tools
created specically for electrical engineering and physics
undergraduate students and professors. It contains an
array of built-in training signals, a comprehensive oscil-
loscope lab guide and tutorial written specically for the
undergraduate student, and an oscilloscope fundamentals
PowerPoint slide set for professors and lab assistants. For
more information, refer to www.keysight.com/nd/EDK.
Also available are DreamCatcher’s full semester applica-
tion-specic courseware written around Keysight test and
measurement equipment: www.dreamcatcher.asia/cw.
With features such as the ability to disable autoscale and
the 50- Ohm input data path, the InniiVision X-Series is a
perfect choice for education.
Get your students to quickly put the scope to work
Intuitive localized front panel design with pushable knobs
for quick access to commonly used oscilloscope functions
helps students spend more time learning the concepts and
less time learning how to use the oscilloscope. Enable your
students to answer their own questions with the localized
built-in help system that provides quick access by simply
pressing and holding any button.
Stretch your budget over the long term
Save money with an industry-exclusive built-in 20 MHz
WaveGen, instead of a separate function generator. Buy
what you need today and protect your investment in the
future with the only oscilloscopes in this class with up-
gradable bandwidth, 8 digital channels (MSO), WaveGen,
integrated digital voltmeter and measurement applica-
tions. Get long scope life and keep repair costs to a mini-
mum with a standard 5-year warranty*, and an instrument
reliability you’ve come to expect from the leader in test
and measurement equipment.
*Applies to all orders on or after 1/1/2013.
Optimize lab bench space
With 5 instruments in 1, you will save on precious lab
bench space by getting an oscilloscope, logic timing ana-
lyzer, serial protocol analyzer, WaveGen function genera-
tor and integrated digital voltmeter all in one innovative
instrument with a footprint that is only 5.57 inches deep.
With the large 8.5-inch WVGA display, you can easily view
all signals on one screen with enough viewing area for
more than one student to view.
Designed with education in mind
Keysight Technologies
DSOXEDK Educator’s
Oscilloscope Training Kit
Lab Guide and Tutorial for
Undergraduate Electrical
Engineering and Physics
Students
11 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
8.5‑inch high resolution
wide screen display
reveals subtle details
that most scopes
don’t show you
Get up to eight integrated
digital channels
WaveGen –
Industry first
built‑in function
generator
Built‑in USB port
makes it easy to
save your work and
update your system
software quickly
Oscilloscope shown actual size
www.keysight.com/nd/BenchVue
8.5-inch high
resolution wide
screen display
reveals subtle details
that most scopes
don’t show you
Oscilloscope shown actual size
WaveGen –
Industry first
built-in
function
generator
Get up to eight integrated
digital channels
Built-in USB port
makes it easy to
save your work and
update your system
software quickly
12 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
Quick summary
display of
sample rate,
channel
settings and
measurements
Demo and
training
signals
Quickly pan and
zoom for analysis
with MegaZoom
IVs instant
response and
optimum resolution
Dedicated
keys for
quick access
to digital
channels,
serial analysis,
math functions
and reference
waveforms
Navigation front
panel controls
make it easy to
play, stop, rewind
and fast forward
through waveforms
Autoscale lets you
quickly display any
analog or digital
active signals,
automatically
setting the vertical,
horizontal and
trigger controls for
the best display,
while optimizing
memory
Integrated
digital
voltmeter
13 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
Step 1. Choose your bandwidth and channel count.
InniiVision 2000 X-Series scopes
2002A 2004A 2012 A 2014A 2022A 2024A
Bandwidth* (–3 dB) 70 MHz 100 MHz 200 MHz
Calculated rise time (10-90%) ≤ 5 ns ≤ 3.5 ns ≤ 1.75 ns
Input channels DSOX 2 4 2 4 2 4
MSOX 2 + 8 4 + 8 2 + 8 4 + 8 2 + 8 4 + 8
* For example, if you chose 100 MHz, 2+8 channels, the model number will be MSOX2014A.
Step 2. Tailor your scope with measurement applications to save time and money.1
Application 2000 X-Series
1 Megapoint memory upgrade DSOX2MEMUP (-010)
Embedded serial triggering and analysis (I²C, SPI) DSOX2EMBD (-LSS)*
Computer serial triggering and analysis (RS232/422/485/UART) DSOX2COMP (-232)*
Automotive serial triggering and analysis (CAN, LIN) DSOX2AUTO (-AMS)*
WaveGen (built-in function generator) DSOX2WAVEGEN (-001)
Integrated digital voltmeter DSOXDVM (-DVM)
Educator’s kit DSOXEDK (-EDK)
Mask testing DSOX2MASK (-LMT)
Segmented memory DSOX2SGM (-SGM)
InniView oscilloscope analysis software N8900A
Keysight spectrum visualizer (ASV) 64997A
1. See pages 20-21 for more detailed information on upgradability, and installation process.
* Serial trigger and decode application will not run simultaneously with digital channels.
Step 3. Choose your probes2
Probes 2000 X-Series
N2862B 150 MHz 10:1 passive probe Standard one per channel for 70 and 100 MHz models
N2863B 300 MHz, 10:1 passive probe Standard one per channel for 200 MHz models
N6459-60001 8-channel logic probe and accessory kit Standard on MSO models or with DSOX2MSO upgrade
N2889A 350 MHz 10:1/1:1 passive probe Optional
10070D 20 MHz 1:1 passive probe with probe ID Optional
10076A 250 MHz 100:1, 4 kV high-voltage passive probe with probe ID Optional
N2791A 25 MHz, ±700 V high-voltage differential probe Optional
N2792A 200 MHz 10:1 differential probe Optional
1146A 100 kHz, 100 A, AC/DC current probe Optional
2. See page 20 for probe compatibilty table. For more information on probes and accessories, see the Keysight literature 5968-8153EN
Step 4. Add the nal touches.
Recommended accessories 2000 X-Series
LAN/VGA connection module DSOXLAN
GPIB connection module DSOXGPIB
Rack mount kit N6456A
Soft carrying case and front panel cover N6457A
Hard copy manual N6458A
Front panel cover (only) N2747A
Conguring your InniiVision X-Series oscilloscope
14 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
Performance characteristics
* Denotes warranted specications, all others are typical.
Specications are valid after a 30-minute warm-up period and from ±10 °C rmware calibration temperature.
** 1 mV/div and 2 mV/div is a magnication of 4 mV/div setting. For vertical accuracy calculations, use full scale of 32 mV for 1 mV/div
and 2 mV/div sensitivity setting.
Specication overview
2002A 2004A 2012 A 2014A 2022A 2024A
Bandwidth * (–3 dB) 70 MHz 100 MHz 200 MHz
“Calculated rise time (10-90%)” ≤ 5 ns ≤ 3.5 ns ≤ 1.75 ns
Input channels DSOX 2 4 2 4 2 4
MSOX 2 + 8 4 + 8 2 + 8 4 + 8 2 + 8 4 + 8
Maximum sample rate 2 GSa/s half-channel interleaved, 1 GSa/s per channel
Maximum memory depth 100 kpts per channel (standard), 1 Mpt per channel (optional with DSOX2MEMUP)
Display size and type 8.5-inch WVGA with 64 levels of intensity grading
Waveform update rate > 50,000 waveforms per second
Vertical system analog channels
Input coupling AC, DC
Input sensitivity range 1 mV/div to 5 V/div**
Input impedance 1 MΩ ± 2% (11 pF)
Vertical resolution 8 bits (measurement resolution is 12 bits with averaging)
Dynamic range ±8 divisions from center screen
Maximum input voltage CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk
CAT II 300 Vrms, 400 Vpk; with N2862B or N2863B 10:1 probe: 300 Vrms
DC vertical accuracy ±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale] **
DC vertical gain accuracy* ±3% full scale (≥ 10 mV/div); ±4% full scale (< 10 mV/div) **
DC vertical offset accuracy ±0.1 div ± 2mV ±1% of offset setting
Channel-to-channel isola-
tion
200 MHz ~ 1 GHz ≥ 40 dB from DC to maximum specied bandwidth of each model
1.5 GHz ≥ 40 dB from DC to 1 GHz, ≥ 35 dB from 1 GHz to 1.5 GHz
Position/offset range 1 MΩ 1 mV to 200 mV/div: ±2 V, > 200 mV to 5 V/div: ± 50V
Hardware bandwidth limits Approximately 20 MHz (selectable)
Horizontal system analog channels
2002A 2004A 2012 A 2014A 2022A 2024A
Time base range 5 ns/div to 50 s/div 2 ns/div to 50 s/div
Horizontal resolution 2.5 ps
Time base accuracy* 25 ppm ±5 ppm per year (aging)
Time base delay time range Pre-trigger Greater of 1 screen width or 200 μs (400 μs in interleaving mode)
Post-trigger 1 s to 500 s
Channel-to-channel deskew range ± 100 ns
Δ Time accuracy (using cursors) ± (time base accuracy* reading) ± (0.0016 * screen width) ± 100 ps
15 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
Acquisition modes
Normal
Peak detect Capture glitch as narrow as 500 ps at all timebase settings.
Averaging Select from 2,4,8,16, 64... to 65,536
High resolution mode 12 bits of resolution when ≥ 20 µs/div
Segmented Re‑arm time= 19 µs (minimum time between trigger events)
Trigger system
Trigger modes Normal (triggered): requires trigger event for scope to trigger
Auto: triggers automatically in absence of trigger event
Single: triggers only once on a trigger event, press [Single] again for scope to nd another trigger
event, or press [Run] to trigger continuously in either Auto or Normal mode
Force: front panel button that forces a trigger
Trigger coupling Coupling selections: AC, DC, noise reject, LF reject and HF reject.
Trigger source Each analog channel, each digital channel (MSO models or DSOX2MSO upgrade, Ext, WaveGen, line)
Trigger sensitivity (internal)* < 10 mV/div: greater of 1 div or 5 mV; ≥ 10 mV/div: 0.6 div
Trigger sensitivity (external)* 200 mV (DC to 100 MHz); 350 mV (100 MHz ‑ 200 MHz)
External trigger input Included on all models
Trigger type selections
All 2000 X-Series models
Edge Trigger on a rising, falling, alternating or either edge of any source
Pulse width Trigger on a pulse on a selected channel, whose time duration is less than a value, greater than a value,
or inside a time range
Minimum duration setting: 2 ns- 10 ns (depends on bandwidth)
Maximum duration setting: 10 s
Pattern Trigger when a specified pattern of high, low, and don’t care levels on any combination of analog, digital,
or trigger channels is [entered | exited]. Pattern must have stabilized for a minimum of 2 ns to qualify as
a valid trigger condition.
Video Trigger on all lines or individual lines, odd/even or all fields from composite video, or broadcast
standards (NTSC, PAL, SECAM, PAM‑M)
I²C (optional) Trigger on I²C (Inter‑IC bus) serial protocol at a start/stop condition or user defined frame with address
and/or data values. Also trigger on missing acknowledge, address with no accq, restart, EEPROM read,
and 10‑bit write.
SPI (optional) Trigger on SPI (Serial Peripherial Interface) data pattern during a specific framing period. Supports positive
and negative Chip Select framing as well as clock Idle framing and userspecified number of bits per frame.
CAN (optional) Trigger on CAN (controller area network) version 2.0A and 2.0B signals. Trigger on the start of frame
(SOF) bit (standard). Remote frame ID (RTR), data frame ID (~RTR), remote or data frame ID, data frame
ID and data, error frame, all errors, acknowledge error and overload frame.
LIN (optional) Trigger on LIN (Local Interconnect Network) sync break, sync frame ID, or frame ID and data.
RS232/422/485/UART
(optional)
Trigger on Rx or Tx start bit, stop bit or data content
Performance characteristics (continued)
* Denotes warranted specications, all others are typical.
Specications are valid after a 30-minute warm-up period and from ±10 °C rmware calibration temperature.
16 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
Waveform math
Operators Add, subtract, multiply, FFT
FFT Windows: Hanning, at top, rectangular; Blackman-Harris - up to 64 kpts resolution
Sources Math functions available between any two channels
Display characteristics
Display 8.5-inch WVGA
Resolution 800 (H) x 480 (V) pixel format (screen area)
Interpolation Sin(x)/x interpolation (using FIR lter; used when there is less than one sample per column of the display)
Persistence Off, innite, variable persistence (100ms-60s)
Intensity gradation 64 intensity levels
Modes Normal
XY - XY mode changes the display from voltage versus time scale to a volts versus volts scale
Roll – Displays the waveform moving across the screen from right to left much like a strip chart recorder
MSO (digital channels)
Upgradable from DSO Yes
MSO channels 8 channels (D0 to D7)
Maximum sample rate 1 GSa/s
Maximum record length 500 kpts per channel (digital channels only)
125 kpts per channel (analog and digital channels)
Threshold selections TTL (+1.4 V), CMOS (+2.5 V), ECL (-1.3 V), User-denable (±8.0 V in 10 mV stops)
Threshold accuracy* ± (100 mV + 3% of threshold settings)
Maximum input dynamic
range
±10 V about threshold
Minimum voltage swing 500 mVpp
Input impedance 100 kΩ ± 2% at probe tip, ~8 pF
Minimum detectable pulse
width
5 ns
Channel-to-channel skew 2 ns (typical), 3 ns (maximum)
Performance characteristics (continued)
* Denotes warranted specications, all others are typical.
Specications are valid after a 30-minute warm-up period and from ±10 °C rmware calibration temperature.
** 1 mV/div and 2 mV/div is a magnication of 4 mV/div setting. For vertical accuracy calculations, use full scale of 32 mV for
2 mV/div sensitivity setting.
Cursors
Types Amplitude, time , frequency (FFT), manual, tracking, binary, HEX
Measurements ΔT, 1/ΔT, ΔV/X, 1/ΔX, ΔY, Phase and Ratio
Cursors** Single cursor accuracy:
±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]
Dual cursor accuracy:
±[DC vertical gain accuracy + 0.5% full scale]*
Automatic waveforms measurements
Voltage Snapshot all, maximum, minimum, peak-to-peak, top, base, amplitude, overshoot, preshoot, average- N
cycles, average-full screen, DC RMS- N cycles, DC RMS- full screen, AC RMS- N cycles
Time Period, frequency, rise time, fall time, + width, – width, duty cycle, delay AB (rising edge),
delay AB (falling edge), phase AB (rising edge,) and phase AB (falling edge)
17 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
WaveGen – built-in function generator (specications are typical)
Waveforms Sine, square, pulse, triangle, ramp, noise, DC
Sine Frequency range: 0.1 Hz to 20 MHz
Amplitude atness: ±0.5 dB (relative to 1 kHz)
Harmonic distortion: –40 dBc
Spurious (non harmonics): –40 dBc
Total harmonic distortion: 1%
SNR (50 ohm load, 500 MHz BW) : 40 dB (Vpp ≥ 0.1 V); 30 dB (Vpp <0.1 V)
Square wave/pulse Frequency range: 0.1 Hz to 10 MHz
Duty cycle: 20 to 80%
Duty cycle resolution: Larger of 1% or 10 ns
Pulse width: 20 ns minimum
Pulse width resolution: 10 ns or 5 digits, whichever is larger
Rise/fall time: 18 ns (10 to 90%)
Overshoot: < 2%
Asymmetry (at 50% DC): ±1% ± 5 ns
Jitter (TIE RMS): 500 ps
Ramp/triangle wave Frequency range: 0.1 Hz to 100 kHz
Linearity: 1%
Variable symmetry: 0 to 100%
Symmetry resolution: 1%
Noise Bandwidth: 20 MHz typical
Frequency Sine wave and ramp accuracy:
130 ppm (frequency < 10 kHz)
50 ppm (frequency > 10 kHz)
Square wave and pulse accuracy:
[50+frequency/200] ppm (frequency < 25 kHz)
50 ppm (frequency ≥ 25 kHz)
Resolution: 0.1 Hz or 4 digits, whichever is larger
Amplitude Range:
20 mVpp to 5 Vpp into Hi-Z
10 mVpp to 2.5 Vpp into 50 ohms
Resolution: 100 µV or 3 digits, whichever is larger
Accuracy: 2% (frequency = 1 kHz)
DC offset Range:
±2.5 V into Hi-Z
±1.25 V into 50 ohms
Resolution: 100 μV or 3 digits, whichever is larger
Accuracy: ±1.5% of offset setting ±1.5% of amplitude ±1 mV
Trigger output Trigger output available on Trig out BNC
Performance characteristics (continued)
18 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
Integrated Digital Voltmeter
Functions ACrms, DC, DCrms, Frequency
Resolution ACV/DCV: 3 digits Frequency: 5.5 digits
Measuring rate 100 times/ second
Autoranging Automatic adjustment of vertical amplication to maximize the dynamic range of measurements.
Range meter Graphical display of most recent measurement, plus extrema over the previous 3 seconds.
Measurement range (specications are typical)
Frequency Range Vertical Range Vertical Accuracy
ACRms 20 Hz - 100 KHz 100 MHz to 500 MHz: 1 mV/div to 5 V/
div** (1 MΩ and 50 Ohm)
1 GHz model: 1 mV/div to 5 V/div** (1
), 1mV/div to 1V/div (50 Ohm)
[
DC vertical gain accuracy + 0.5% full scale
DCRms 20 Hz - 100 KHz [DC vertical gain accuracy + DC vertical offset ac-
curacy + 0.25% full scale]
DC NA [DC vertical gain accuracy + DC vertical offset ac-
curacy + 0.25% full scale]
Frequency
counter
1Hz – BW of Scope <10 mV/div: greater of 1 div or 5 mV; ≥
10 mV/div: 0.6 div
25 ppm ± 5 ppm per year (aging)
WaveGen – built-in function generator (specications are typical) (Continued)
Modulation Modulation types: AM, FM, FSK
Carrier waveforms: sine, ramp
Modulation source: Internal (no external modulation capability)
AM:
Modulation waveform: sine, square, ramp
Modulation frequency (1Hz to 20 kHz)
Depth: 0% to 100%
FM:
Modulation: sine, square, ramp (1 Hz to 20 kHz)
Modulation frequency (1 Hz to 20 kHz)
Minimum carrier frequency: 10 kHz
Minimum deviation: 1 Hz
Maximum deviation: 100 kHz or (carrier frequency - 9 kHz), whichever is smaller.
FSK:
Modulation: 50% duty cycle square wave
FSK rate: 1 Hz to 20 kHz
Minimum carrier frequency: 10 kHz
Minimum hop frequency: 2 * FSK rate
Performance characteristics (continued)
19 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
Connectivity
Standard ports One USB 2.0 hi-speed device port on rear panel. Supports USBTMC protocol
Two USB 2.0 hi-speed host ports, front and rear panel
Supports memory devices, printers and keyboards
Optional ports GPIB, LAN, WVGA video out
General and environmental characteristics
Power line consumption 100 watts
Power voltage range 100-120V, 50/60/400 Hz; 100-240V, 50/60 Hz ±10% auto ranging
Temperature Operating: 0 to +55 °C
Non-operating: –30 to +71 °C
Humidity Operating: Up to 80% RH at or below +40 °C; up to 45% RH up to +50 °C
Non-operating: Up to 95% RH up to 40 °C; up to 45% RH up to 50 °C
Altitude Operating: up to 4,000 m, Non-operating 15,300 m
Electromagnetic compatibility Meets EMC Directive (2004/108/EC), meets or exceeds IEC 61326-1:2005/EN
61326-1:2006 Group 1 Class A requirement
CISPR 11/EN 55011
IEC 61000-4-2/EN 61000-4-2
IEC 61000-4-3/EN 61000-4-3
IEC 61000-4-4/EN 61000-4-4
IEC 61000-4-5/EN 61000-4-5
IEC 61000-4-6/EN 61000-4-6
IEC 61000-4-11/EN 61000-4-11
Canada: ICES-001:2004
Australia/New Zealand: AS/NZS
Safety UL61010-1 2nd edition, CAN/CSA22.2 No. 61010-1-04
Dimensions 381 mm (15 in) W x 204 mm (8 in) H x 142 mm (5.6 in) D
Weight Net: 3.9 kg (8.5 lbs), shipping: 4.1 kg (9.0 lbs)
Nonvolatile storage
Reference waveform display 2 internal waveforms or USB thumb drive
Waveform storage Set up, .bmp, .png, .csv, ASCII, XY, reference waveforms, .alb, .bin, lister, mask , HDFS
Max USB ash drive size Supports industry standard ash drives
Set ups without USB ash drive 10 internal setups
Set ups with USB ash drive Limited by size of USB drive
InniiVision X-Series physical characteristics
Included standard with oscilloscope
Standard 5-year warranty* (90 days for unserialized accessories)
Standard secure erase
Standard Probe
N2862B 150 MHz 10:1 passive probe Standard one per channel for 70 and 100 MHz models
N2863B 300 MHz, 10:1 passive probe Standard one per channel for 200 MHz models
N6459-60001 8-channel logic probe and accessory kit Standard on MSO models or with DSOX2MSO upgrade
Built-in help language support for English, Japanese, simplied Chinese, traditional Chinese, Korean, German, French, Spanish, Russian,
Portuguese and Italian, Certicate of Calibration, Documentation CD
Interface language support GUI menus: English, Japanese, simplied Chinese, traditional Chinese, Korean, German, French,
Spanish, Russian, Portuguese, Thai, Polish and Italian
Localized power cord
*Applies to all orders on or after 1/1/2013.
For MET/CAL procedures, click on the Cal Labs solutions link below Cal Labs Solutions
http://www.callabsolutions.com/products/Keysight/ These procedures are FREE to customers.
20 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
Bandwidth upgrade models
2000 X-Series
DSOX2BW12 70 MHz to 100 MHz, 2 ch, License only
DSOX2BW14 70 MHz to 100 MHz, 4 ch, License only
DSOX2BW22 100 MHz to 200 MHz, 2 ch, License only
DSOX2BW24 100 MHz to 200 MHz, 4 ch, License only
License-only bandwidth upgrades and measurement applications
Process description
Place order for a license only bandwidth upgrade or measure-
ment appliction product to a Keysight sales partner. If multiple
bandwidth upgrade steps are needed, order all the corresponding
upgrade products required to get from current bandwidth to de-
sired bandwidth. In the case where the new bandwidth requires
higher bandwidth passive probes, they are included with the
upgrade. For the DSOX2BW22 and DSOX2BW24, the N2863B
10:1 300 MHz passive probes (1 per channel) will be sent with the
upgrade.
Receive a paper or electronic .pdf Entitlement Certicate docu-
ment for any of the orderable measurement applications For
bandwidth upgrades only, you receive a stick-on label document
indicating upgraded bandwidth specication.
Use Entitlement Certicate or electronic .pdf document contain-
ing instructions and certicate number needed to generate a
license le for a particular 2000 or 3000 X-Series oscilloscope
model number and serial number unit.
Receive the licensed le and installation instructions via email.
Copy license le (.lic extension) from email to a
USB drive and follow instructions in email to install the
purchased bandwidth upgrade or measurement application on
the oscilloscope.
For bandwidth upgrades only, attach bandwidth upgraded
stick-on labels to front and rear panels of the oscilloscope. Model
number and serial number of the oscilloscope do not change.
Measurement applications
DSOX2MEMUP Upgrade to 1 Mpts per channel
DSOX2COMP Computer serial triggering and analysis
(RS232/422/485/UART)
DSOX2AUTO Automotive serial triggering and analysis
(CAN, LIN)
DSOX2EMBD Embedded serial triggering and analysis (I2C,
SPI)
DSOX2WAVEGEN WaveGen (built-in function generator)
DSOXDVM Integrated digital voltmeter
DSOXEDK Educator’s kit
DSOX2MASK Mask testing
DSOX2SGM Segmented memory
DSOX2MSO Upgrade to 8 digital timing channels
Process description
1
2
3
4
5
6
21 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
Keysight Technologies Oscilloscopes
Multiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful applications
22 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
www.axiestandard.org
AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an
open standard that extends the AdvancedTCA for general purpose and
semiconductor test. Keysight is a founding member of the AXIe consortium.
ATCA®, AdvancedTCA®, and the ATCA logo are registered US trademarks of
the PCI Industrial Computer Manufacturers Group.
www.lxistandard.org
LAN eXtensions for Instruments puts the power of Ethernet and the
Web inside your test systems. Keysight is a founding member of the LXI
consortium.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s commitment to superior product quality and lower total cost
of ownership. The only test and measurement company with three-year
warranty standard on all instruments, worldwide.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to five years of protection and no budgetary surprises to ensure your
instruments are operating to specification so you can rely on accurate
measurements.
www.keysight.com/go/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2008
Quality Management System
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
www.keysight.com/find/2000x-series
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada (877) 894 4414
Brazil 55 11 3351 7010
Mexico 001 800 254 2440
United States (800) 829 4444
Asia Pacic
Australia 1 800 629 485
China 800 810 0189
Hong Kong 800 938 693
India 1 800 112 929
Japan 0120 (421) 345
Korea 080 769 0800
Malaysia 1 800 888 848
Singapore 1 800 375 8100
Taiwan 0800 047 866
Other AP Countries (65) 6375 8100
Europe & Middle East
Austria 0800 001122
Belgium 0800 58580
Finland 0800 523252
France 0805 980333
Germany 0800 6270999
Ireland 1800 832700
Israel 1 809 343051
Italy 800 599100
Luxembourg +32 800 58580
Netherlands 0800 0233200
Russia 8800 5009286
Spain 800 000154
Sweden 0200 882255
Switzerland 0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
United Kingdom 0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-09-24-14)
23 | Keysight | InniiVision 2000 X-Series Oscilloscopes - Data Sheet
This information is subject to change without notice.