TWO PEARL BUCK COURT
l
BRISTOL, PA 19007-6812
l
TEL 215-781-6400
l
FAX 215-781-6403
l
www.pulsespecialty.com
Low Power Pulse Transformers — 18
These non-QPL interface transformers are built and tested in ISO
9002 approved facilities. They conform to all electrical and physi-
cal parameters of MIL-PRF-21038/27. Choose one of three operat-
ing temperature ranges including 0Oto +70OC, -40Oto +85OC, or
-55Oto +125OC.
ndual ratio, single interface (see schematic)
nthrough the board package
nfor use in MIL-STD-1553 applications
nstandard height, 0.250 in.
nperformance to MIL-PRF-21038/27 requirements
nbuilt in ISO 9002 facility
Value Series (COTS)
through the board MIL-PRF-21038
Interface Transformers
SUMMARY PERFORMANCE SPECIFICATIONS
Impedance.................................................................................. see table, next page
Droop.............................................................................................................. <20%
Overshoot.................................................................................................. +1V max
Common mode rejection (CMR)................................................................. >45 dB
Frequency range (no load)............................................................. 75 kHz to 1MHz
Operating temperature range......................................... see table, next page
Weight....................................................................................................... <5 grams
Insulation resistance (min)........................................... 10K megohms @ 250 Vdc
Dielectric withstanding voltage................................................................ 100 Vrms
0Oto 70OC
-40Oto +85OC
-55O to +125OC
prefix
operating temp.
N
C
TQ
The transformer package shown
on this page is also available fully
qualified to MIL-PRF-21038/27
requirements.
APPLICABLE SPECIFICATIONS
nMIL-STD-1553B
nMIL-STD-202
nMIL-T-10727
nMIL-PRF-21038
nISO 9002