Hour meter 24 x 48 digital hours meters Types FSA01, FSA02 * 8-digit LCD display * 8 mm digits * Reset button with locking function * 8 years battery lifetime * Electrical or manual reset input * Setting time mode (through electical control) * For front panel mounting * 24 x 48 mm housing Product Description Ordering Key 24 x 48 mm hour meters for flush mounting. 10 to 260 V AC or DC input. The front key, which can be locked, allows fast and easy input Housing Function Type Item number Output Input range reset. NPN input to set the time range (Mode) and to enable the device reset. FSA 01 X W24 Type Selection Mounting Input Model Time range Front panel Front panel 10 to 260 V DC/AC 10 to 260 V DC/AC FSA01XW24 FSA02XW24 99999h 59m 9999h 59m 59s Input Specifications Input timer Input type Low level High level Input resistance Reset Input type or or 99999.99h 9999999.9s General Specifications Power supply Optocoupler (10 to 260 V AC/DC) 0 to 2 V AC/DC 10 to 260 V AC/DC 160 k Optocoupler (10 to 260 V AC/DC) 0 to 2V AC/DC 10 to 260 V AC/DC 16 ms 30 Hz 160 k Low level Hight level Min pulse time Max frequency Input resistence Electrical locking of the reset key Input type NPN open collector or voltage free contact 0 to 0,7 VDC Low level High level 3 to 5 VDC Input resistance 2,2 M Time range switching Input type NPN open collector or voltage free contact 0 to 0,7 V DC Low level 3 to 30 V DC High level Input resistance 2,2 M Specifications are subject to change without notice (12.09.06) Display Counting range Digit height Environment Degree of protection Pollution degree Operating temperature Storage temperature Housing dimesions Weight Panel cut out Screw terminals Tightening torque Accuracy Approvals CE Marking EMC Immunity Emission Non-reaplaceable lithium battery (lifetime up to 8 years at 20C) 0 to 99999999 (with zero suppresion) 8 mm (EN 60529) IP 65 front 2 -10 to +55C, R.H.<85% -20 to +70C 24 x 48 mm 50 g 22,2+0,3 x 45+0,6 mm Max. 0.5 Nm according to IEC EN 60947 <100 ppm UL Yes Electromagnetic Compatibillity According to EN 61000-6-2 According to EN 61000-6-3 1 FSA01, FSA02 Pin assigment and adjustable operating modes Screw terminal Designation Model FSA01XW24 FSA02XW24 1 2 3 4 5 6 7 8 INP A Common INP B Reset Enable Time range control input (Mode) GND - - Conctact with Common Reset key Not active= 99999h 59m GND= 99999,99h Timer connection Reset locking No 0 VDC input for INP A input function input Conctact with Not active= and INP B (NPN) 9999h 59m 59s GND= 9999999,9s No function Wiring Diagram FSA01XW24 - FSA02XW24 (Reset enable and Mode: voltage free contact inputs) FSA01XW24 - FSA02XW24 (Reset enable and Mode: NPN inputs) Dimensions 2 Specifications are subject to change without notice (12.09.06)