AFL Sensors
- 1 -
www.nve.com phone: 952-829-9217 fax: 952-829-9189
AFL-Series Sensors—Low Power, Low Voltage Digital Switches
Features:
Low voltage operat i o n t o 0. 9 V
Low current consumption
Digital switch output
Precise detection of low magnetic fields
Ultra-small packages (MSOP8 and TDFN 6)
Available in millimeter-scale die
Cannot be damaged by la rge magnetic fields
Description:
NVE’s AFL-Series Sensors are digital switches designed to run at very low voltages and currents. The
parts can operate from a single battery. The output is configured as a switch to detect magnetic fields,
switching on at a specified magnetic field, and off when the field is removed. Current-sinking or
current-sourcing output configurations are available. Both configurations supply up to 100 µA. An
external pull-up or pull-down resistor is required. The devices are available in MSOP8 or TDFN6
packages, or in die form.
AFL Product Selection Guide
AFL-Series part numbers follow the general form below. The first “x” in the part number specifies the
voltage range, the second “x” denotes the output configuration, the third “x” specifies the magnetic
operate point, and the last character pair specifies the package. The following sections define these
options.
Voltage
Range of
Operation
Package Type
Magnetic
Operate Point
Output
-xAFLxxxx
AFL Sensors
- 2 -
www.nve.com phone: 952-829-9217 fax: 952-829-9189
Voltage Range of Operation
The first numeric digit of the part number in the form AFLxxx-xx specifies the operating voltage
range. Four ranges are available:
NVE AFL xxx-xx
Number Voltage Range of Operation
0 0.9 V – 1.3 V
1 1.8 V – 2.5 V
2 2.7 V – 3.6 V
3 4.5 V – 5.5 V
The quiescent supply current specifications apply within these ranges. Parts may be operated at higher
voltage than shown up to a maximum of 7 V, but the quiescent current will increase. For example, a
“1xx-xx” part can be operated up to 3.0 V although it might it exceed the quiescent current
specification.
NVE can supply custom parts for different voltage ranges. Minimum order quantities, special pricing,
NRE charges, and lead times may apply. Please contact NVE with your requirements.
Output
The second digit of the part number specifies the output configuration. Four output types are available:
NVE AFL xxx-xx
Number Output Type
0 Normally Off, Current Sink
1 Normally On, Current Sink
2 Normally On, Current Source
3 Normally Off, Current Source
“Normally Off” means that with no magnetic field applied the output will not provide current; when
the magnetic field is applied, the output current will turn on. “Normally On” is op posite. Parts will sink
or source up to 100 µA. Output current is not included in the quiescent current specification.
AFL Sensors
- 3 -
www.nve.com phone: 952-829-9217 fax: 952-829-9189
Magnetic Operate Point and Direction of Sensitivity
Standard magnetic operate points are shown in the table below. Non-standard magnetic operate points
are available, but special pricing, minimum order quantities, NRE charges, and lead times may apply.
NVE AFL xxx-xx
Number Magnetic Operate Point
0 10 Oe
1 20 Oe
2 28 Oe
3 40 Oe
4 80 Oe
5 7 Oe
All AFL-Series parts feature cross-axis sensitivity as shown in the following diagrams:
Package Types
AFL-Series parts are available in two different packages: an 8-pin Micro Small Outline Package
(MSOP) and a 6-pin ultra-miniature leadless TDFN package. Parts are also available in die form.
Package type part numbers are shown in the table below; drawings are at the end of this specification.
NVE AFL xxx-xx
Number Package
Type
00 MSOP8
01 IC Only
10 TDFN6
Available Parts
The following parts in this series are currently available:
AFL000-00E AFL000-10E AFL000-01
AFL001-10E AFL002-10E AFL005-10E
AFL020-00E AFL030-00E AFL100-00E
AFL100-10E AFL103-01 AFL200-00E
AFL300-00E
Notes:
1. Part types are continuosly added. Contact factory for
current part availability.
2. The “E” suffix indicates a lead-free, RoHS-compliant
package.
3. All die versions (-01 suffix) are lead-free and RoHS
compliant.
Cro ss Axi s
MSOP 8
VCC
Test
Tes
t
Tes
t
Outpu
t
Ground
N/C
Tes
t
Cro ss Axi s
TDFN 6
VCC
Tes
t
Tes
t
Ground
Tes
t
Outpu
t
AFL Sensors
- 4 -
www.nve.com phone: 952-829-9217 fax: 952-829-9189
Electrical and Magnetic Specifications
Paramete
r
Min. Typ. Max. Units
Magnetic Operate Point (AFLxx0-xx) 7 10 13 |Oersteds|
Operate/Release Differential ( AFLxx0-xx) 1 6 |Oersteds|
Magnetic Operate Point (AFLxx1-xx) 15 20 25 |Oersteds|
Operate/Release Differential ( AFLxx1-xx) 3 10 |Oersteds|
Magnetic Operate Point (AFLxx2-xx) 21 28 34 |Oersteds|
Operate/Release Differential ( AFLxx2-xx) 3 10 |Oersteds|
Magnetic Operate Point (AFLxx5-xx) 4 7 10 |Oersteds|
Operate/Release Differential ( AFLxx5-xx) 1 6 |Oersteds|
Operating Voltage (AFL0x x-xx) 0.9 1.1 1.3 Volts
Operating Voltage (AFL1x x-xx) 1.8 2.2 2.5 Volts
Operating Voltage (AFL2x x-xx) 2.7 3.2 3.6 Volts
Operating Voltage (AFL3x x-xx) 4.5 5.0 5.5 Volts
Quiescent Current (AFL000-xx) 20 35 55 μA
Quiescent Current (AFL020-xx) 30 50 75 μA
Quiescent Current (AFL030-xx) 15 35 55 μA
Quiescent Current (AFL100-xx) 25 35 45 μA
Quiescent Current (AFL200-xx) 30 35 45 μA
Quiescent Current (AFL300-xx) 30 40 50 μA
Maximum Output Drive Current (Sink or Source) 100 μA
VOL at 100 μA Output Drive Current 0.200 Volts
VOH at 100 μA Output Drive Current VCC
0.150 Volts
Frequency Respons e 100 KHz
Temperature Range of Operation 20 85
°C
Notes:
1. Large magnetic fields WILL NOT damage NVE GMR Sensors
2. One Oersted (Oe) = 1 G auss in air = 0.1 mT
AFL Sensors
- 5 -
www.nve.com phone: 952-829-9217 fax: 952-829-9189
Operation
The magnetic field must be applied planar to the package in the direction of sensitivity. When the
magnetic field reaches the magnetic operate point, the output will turn on. There should be a pull-up or
pull-down resistor on the output terminal.
Fuctional Diagrams and Pinout
VCC
(Pin 1)
Test
N/C
Test
Output
Test
Ground
Test
AFL000-00
GMR Bridge
Direction of Sensitivity
VCC
(Pin 1)
Test
Test
Output
Test
Ground
AFL000-10
GMR
Bridge
AFL Sensors
- 6 -
www.nve.com phone: 952-829-9217 fax: 952-829-9189
IC Drawing and Layout
The IC is approximately 1.45 mm x 1.5 mm. A die drawing is shown below:
Direction of Se nsi t ivi t y
AFL Sensors
- 7 -
www.nve.com phone: 952-829-9217 fax: 952-829-9189
Package Drawings and Specifications
MSOP8
Notes:
1. The MSOP8 package has thermal power dissipation of 320°C/Watt in free air.
2. Thermal performance is improved when the package is soldered to a circuit board.
2.5 mm x 2.5 mm TDFN6
Notes:
1. The TDFN6 package has thermal power dissipation of 320°C/Watt in free air.
2. Thermal performance is improved when the package is soldered to a circuit board.
Dimensions: inches (mm)
.118 (3.00)
.021 (.533)
.154 (3.91)
.034 (.86) .040 (1.02)
.004 (.102) min
.012 (.305) max
.0256 (.65) X 6
NVE
XXX
.118 (3.00)
.193 (4.90)
.012 TYP.
.118
(3.00)
dimensions in mm
AFL Sensors
- 8 -
www.nve.com phone: 952-829-9217 fax: 952-829-9189
The complete part number will not fit on TDFN6 or MSOP8 pack ages, so a three-digit code is used. The package codes are
listed below:
Part Numbe
r
Marking Code
AFL000-00E
AFL000-10E
AFL001-10E
AFL002-10E
AFL005-10E
AFL020-00E
AFL030-00E
AFL100-00E
AFL100-10E
AFL200-00E
AFL300-00E
PBBe
QBBe
QBXe
QBLe
QBKe
PBCe
PBDe
PBFe
QBFe
PBGe
PBHe
©NVE Corporation
All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner.
SB-00-015 February 2012
AFL Sensors
- 9 -
www.nve.com phone: 952-829-9217 fax: 952-829-9189
Datasheet Limitations
The information and data provided in datasheets shall define the specification of the product as agreed between NVE and its customer, unless NVE
and customer have explicitly agreed otherwise in writin g. All specifications are based on NVE test protocols. In no event however, shall an
agreement be valid in which the NVE product is deemed to offer functions and qualities beyond those described in the datasheet.
Limited Warranty and Liability
Information in this document is believed to be accurate and reliable. However, NVE does not give any representations or warranties, expressed or
implied, as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information.
In no event shall NVE be liable for any indirect, incidental, punitive, special or consequential damages (including, without limitation, lost profits,
lost savings, business interruption, costs related to the removal or replacement of any products or rework charges) whether or not such damages are
based on tort (including negligence), warranty, breach of contract or any other legal theory.
Right to Make Changes
NVE reserves the right to make changes to information published in this document including, without limitation, specifications and product
descriptions at any time and without notice. This document supersedes and replaces all information supplied prior to its publication.
Use in Life-Critical or Safety-Critical Applications
Unless NVE and a customer explicitly agree otherwise in writing, NVE products are not designed, authorized or warranted to be suitable for use in
life support, life-critical or safety-critical devices or equipment. NVE accepts no liability for inclusion or use of NVE products in such applications
and such inclusion or use is at the customer’s own risk. Should the customer use NVE products for such application whether authorized by NVE or
not, the customer shall indemnify and hold NVE harmless against all claims and damages.
Applications
Applications described in this datasheet are illustrative only. NVE makes no representation or warranty that such applications will be suitable for
the specified use without further testing or modification.
Customers are responsible for the design and operation of their applications and products using NVE products, and NVE accepts no liability for
any assistance with applications or customer product design. It is customer’s sole responsibility to determine whether the NVE product is suitable
and fit for the customer’s applications and products planned, as well as for the planned application and use of customer’s third party customers.
Customers should provide appropriate design and operating safeguards to minimize the risks associated with their applications and products.
NVE does not accept any liability related to any default, damage, costs or problem which is based on any weakness or default in the customer’s
applications or products, or the application or use by customer’s third party customers. The customer is responsible for all necessary testing for the
customer’s applications and products using NVE products in order to avoid a default of the applications and the products or of the application or
use by customer’s third party customers. NVE accepts no liability in this respect.
Limiting Values
Stress above one or more limiting values (as defined in the Absolute Maximum Ratings System of IEC 60134) will cause permanent damage to the
device. Limiting values are stress ratings only and operation of the device at these or any other conditions above those given in the recommended
operating conditions of the datasheet is not warranted. Constant or repeated exposure to limiting values will permanently and irreversibly affect the
quality and reliability of the device.
Terms and Conditions of Sale
In case an individual agreement is concluded only the terms and conditions of the respective agreement shall apply. NVE hereby expressly objects
to applying the customer’s general terms and conditions with regard to the purchase of NVE products by customer.
No Offer to Sell or License
Nothing in this document may be interpreted or construed as an offer to sell products that is open for acceptance or the grant, conveyance or
implication of any license under any copyrights, patents or other industrial or intellectual property rights.
Export Control
This document as well as the items described herein may be subject to export control regulations. Export might require a prior authorization from
national authorities.
Automotive Qualified Products
Unless the datasheet expressly states that a specific NVE product is automotive qualified, the product is not suitable for automotive use. It is
neither qualified nor tested in accordance with automotive testing or application requirements. NVE accepts no liability for inclusion or use of non-
automotive qualified products in automotive equipment or applications.
In the event that customer uses the product for design-in and use in automotive applications to automotive specifications and standards, customer
(a) shall use the product without NVE’s warranty of the product for such automotive applications, use and specifications, and (b) whenever
customer uses the product for automotive applications beyond NVE’s specifications such use shall be solely at customer’s own risk, and
(c) customer fully indemnifies NVE for any liability, damages or failed product claims resulting from customer design and use of the product for
automotive applications beyond NVE’s standard warranty and NVE’s product specifications.