PRELIMINARY CY28SRC01
Document #: 001-00058 Rev. *A Page 6 of 10
Crystal Recommendations
The CY28SRC01 requires a Parallel Resonance Crystal.
Substituting a series resonance crystal will cause the
CY28SRC01 to operate at the wrong frequency and violate the
ppm specification. For most applications there is a 300-ppm
frequency shift between series and parallel crystals due to
incorrect loading.
Crystal Loading
Crystal loading plays a critical role in achieving low ppm perfor-
mance. To realize low ppm performance, the total capacitance
the crystal will see must be considered to calculate the appro-
priate capacitive loading (CL).
Figure 1 shows a typical crystal configuration using the two
trim capacitors. An important clarification for the following
discussion is that the trim capacitors are in series with the
crystal not parallel. It’s a common misconception that load
capacitors are in parallel with the crystal and should be
approximately equal to the load capacitance of the crystal.
This is not true.
Calculating Load Capacitors
In addition to the standard external trim capacitors, trace
capacitance and pin capacitance must also be considered to
correctly calculate crystal loading. As mentioned previously,
the capacitance on each side of the crystal is in series with the
crystal. This means the total capacitance on each side of the
crystal must be twice the specified crystal load capacitance
(CL). While the capacitance on each side of the crystal is in
series with the crystal, trim capacitors (Ce1,Ce2) should be
calculated to provide equal capacitive loading on both sides.
As mentioned previously, the capacitance on each side of the
crystal is in series with the crystal. This means the total capac-
itance on each side of the crystal must be twice the specified
load capacitance (CL). While the capacitance on each side of
the crystal is in series with the crystal, trim capacitors
(Ce1,Ce2) should be calculated to provide equal capacitance
loading on both sides.
Use the following formulas to calculate the trim capacitor
values for Ce1 and Ce2.
CL....................................................Crystal load capacitance
CLe......................................... Actual loading seen by crystal
using standard value trim capacitors
Ce..................................................... External trim capacitors
Cs ..............................................Stray capacitance (terraced)
Ci .......................................................... Internal capacitance
(lead frame, bond wires etc.)
4 1 Revision Code Bit 0
3 1 Vendor ID Bit 3
2 0 Vendor ID Bit 2
1 0 Vendor ID Bit 1
0 0 Vendor ID Bit 0
Byte 7: Control Register 7 (continued)
Bit @Pup Name Description
Table 4. Crystal Recommendations
Frequency
(Fund) Cut Loading Load Cap Drive
(max.)
Shunt Cap
(max.)
Tolerance
(max.)
Stability
(max.)
Aging
(max.)
14.31818 MHz AT Parallel 12pF - 16pF 1mW 7 pF + 50ppm + 50ppm 5 ppm
Figure 1. Crystal Capacitive Clarification
XTAL
Ce2
Ce1
Cs1 Cs2
X1 X2
Ci1 Ci2
Clock Chip
Trace
2.8pF
Trim
27pF
Pin
3 to 6p
Figure 2. Crystal Loading Example
Load Capacitance (each side)
Total Capacitance (as seen by the crystal)
Ce = 2 * CL – (Cs + Ci)
Ce1 + Cs1 + Ci1
1+Ce2 + Cs2 + Ci2
1
()
1
=
CLe