Product Information Page 2 of 3
ÖLFLEX® VFD with Signal Valid: 04.04.2011
• Class 1, Div. 2 per NEC "National Electrical Code" Art. 336, 392, 501
Product features
• Oil resistant according to UL OIL RES I & II
• Flame retardant according to CSA FT4 UL Vertical-Tray Flame Test
• Water resistant UL Wet Approval 75 °C
• Stationary application
• Occasional flexing
Technical Data
Core identification code
Black with white numbers
Approvals
USA: UL MTW, TC-ER, WTTC 1000V, DP-1, AWM
105°C
Canada: c(UL) CIC/TC FT4, CSA AWM I/II A/M
FT4
Based on
VDE 0245, 250, 281
Specific insulation resistance
> 20 GOhm x cm
Conductor stranding
Fine wire
Minimum bending radius
Occasional flexing: 10 x cable diameter
Static: 4 x cable diameter
Rated voltage
UL/CSA: 600 V (TC, MTW, CIC), WTTC 1000V
IEC U0/U: 600/1000V
Test voltage
7500 V
Protective conductor
G = with protective conductor GN/YE
Range of temperature
Flexing: -5°C up to +90°C(AWM: +105°) Fixed installation:
-25°C up to +90°C(AWM: +105°)
Article List
Part
number
Number
of cores and AWG per
conductor
Outer
diameter in mm
Copper
index kg/km
Weight
kg/km
7416048 4 G 16 + (2 x 18) 13,1 125.0 262
7414048 4 G 14 + (2 x 18) 14,1 160.0 372
7414044 4 G 14 + (2 x 14) 14,8 186.0 402
7412048 4 G 12 + (2 x 18) 15,5 210.0 438
7412044 4 G 12 + (2 x 14) 16,1 239.0 467
7410044 4 G 10 + (2 x 14) 18,4 347.0 705
7408044 4 G 8 + (2 x 14) 24,2 494.0 903