1461-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
DTM165-C Series
Features
CEC, ErP and EISA(1) level V Compliant Models
Wide Range AC Input
Medical Certifi cations
> 87% Average Effi ciency
160W to 165W Medical AC-DC External Power Supplies
Model DTM165PWxxx-C
Input Voltage range VAC 90 - 264VAC (47 - 63Hz)
Inrush Current A <130A at 230VAC input, 25°C ambient cold start
Input Current A 2.5A at 90VAC, Full Load
Power Factor - Meets EN61000-3-2. >0.9 PF
Leakage Current (264VAC 60Hz) uA <300uA
Hold Up Time (Typ) ms >10ms
Temperature Coeffi cient %/°C ±0.05%/°C
Voltage Accuracy % ±1%
Adjustment Range V None
Minimum Load A None
Total Regulation % 12V to 19V Models:±5%, >19V models ±3%
Ripple & Noise % 1%
Short Circuit Protection - <160% - hiccup mode
Overvoltage Protection V 120 - 150% of nominal (Cycle input power to reset)
Effi ciency % >87% average effi ciency
Operating Temperature °C 0 to +60°C, derate linearly 50% load from 40 to 60°C
Storage Temperature °C -10 to +80°C
Humidity (non condensing) %RH 0 - 90%RH
Cooling - Convection
Withstand Voltage VAC Input to Ground 1.5kVAC, Input to Output 4kVAC (Reinforced)(2 x MOPPs)
(Output is isolated from Ground)
Vibration (non operating) - 23.52m/s2 (10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour)
Shock - < 196.1 m/s2 (20G)
Safety Agency Certifi cation - UL60601-1, EN60601-1, IEC60601-1, CE Mark
Effi ciency Level - CEC, ErP, EISA level V
Offl oad Power Consumption W < 0.5W
Conducted & Radiated EMI - EN55011, FCC Part 18 Class B
Immunity - EN55011:2007+A2:2007
Weight (Typ) g 790
Size (WxLxH) in 3.35 x 6.7 x 1.73”
Cable Length mm 1050mm
AC Input Connector - IEC 320-C14 (Accepts IEC 320-C13)
Output Connector - Kycon KPPx-4P or equivalent
Pins 1 & 2: -Vout, Pins 3 & 4: +Vout
Warranty yrs Two Years
Specifi cations
(1) EISA - Energy Independence and Security Act of 2007
Key Market Segments & Applications