K-75
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Weekly/Yearly Timer
LE7M-2
Ordering information
Specifications
W72×H72mm, Weekly/Yearly timer
● Easy to check and change the program setting
● Customizable weekly or yearly unit time setting
and control by user
● Includes daylight saving time function
● Built-in 2 independent control output (relay)
● Flush and surface mounting are in one unit
● Enable to mount on DIN rail with base plate
Model LE7M-2
Power supply 100-240VAC 50/60Hz
Allowable voltage range 90 to 110% of rated voltage
Power consumption Max. 4.2VA
RETURN input Short-circuit or open by switch or relay
Timing program 48 steps for weekly, 24 steps for yearly
Operation mode ON/OFF mode, cycle mode, pulse mode
Mounting Front panel, surface, DIN rail
Time deviation ±15sec./month(ambient temperature: 25) (±4sec. /week)
Temperature error ±0.01% ±0.05sec.(ratio by set time)
Memory protection Over 5 years(at 25)
Control
Output
Contact type SPDT(Single Pole Double Throw)
Contact capacity 250VAC 10A resistive load
Output number Independent 2 output(1c × 2)
Relay
life cycle
Mechanical Min. 5,000,000 operations(switching capacity: 30 times/min)
Electrical Min. 50,000 operations<switching capacity: 20 times/min, 250VAC 10A(resistive load)>
Insulation resistance Min. 100MΩ(at 500VDC megger)
Dielectric strength 2000VAC 50/60Hz for 1minute
Noise strength ±2kV the square wave noise(pulse width: 1) by the noise simulator
Environ
-ment
Ambient temperature -10 to 55, storage: -25 to 65
Ambient humidity 35 to 80%RH
Unit weight Approx. 272g
Item
Size
Output
LE7 M 2
2 2 Relay outputs
M DIN W72×H7mm
LE7 Weekly/Yearly timer
Features
Environment resistance is rated at no freezing or condensation.
Please read “Caution for your safety” in operation
manual before using.
K-76
LE7M-2
N.C.
N.C.
N.C. N.C.
OUT2
OUT1 SOURCE
SOURCE
SOURCE
[Single phase] [Three phase]
COM
COM
COM COM
N.O.
N.O. N.O.
Power of
single
phase
Load Load
Magnetic
Switch
Magnetic
Switch
Power of
three
phase
N.O.
RETURN
INPUT
CONTACT OUT
250VAC 10A
RESISTIVE LOAD
100-240VAC
50/60 4.2VA
6
1
7
2
8
3
9
4
10
5
1 12 23 34 45 5
Connections
Load connection
You must connect a surge absorber to the both ends of the load to prevent from damage or malfunction of this unit when
controlling non-resistive load (ex: magnetic switch, etc).
● In case of controlling the load directly
● In case of controlling the load by using a magnetic switch
S/A
: Surge Absorber
S/A : Surge Absorber
S/A
S/A
N.C.
SOURCE
Power circuit for
load operation
COM
N.O.
부부
12345
Load
K-77
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Weekly/Yearly Timer
86
64
55
64
76.5
DIN rail
67.6 9
55
95 85
95
85
95
9.5
13.5 Panel
67
4-M3 TAP
Base plate
7 60
Min. 91
67.5
Min. 91
72
Unscrew 4 bolts from terminal block.
(Front panel mounting)
(Surface mounting)
Detach terminal block from case and then rotate it 180 degree.
Assemble terminal block to case by using the 4 bolts.
Dimensions & Mounting
How to switch from the ush mounting to surface mounting type
(unit: mm)
68+0.7
0
68+0.7
0
Remove terminals from the body after unscrewing terminal screws, and then assemble terminals to the body after rotating
terminals as shown below.
1) Front panel mounting
2) Surface mounting
3) DIN rail mounting
● Panel cut-out
● Panel hole cut-out
● Base Plate
K-78
LE7M-2
1
2
14
15
5
16
3
4
6
17
18
9
20
19
7
8
10
21
22
11
12
13
ON time OFF time
Parts description
Functions
1. Day indicator
2. Day display
● Light : Day is selected.
● Light-out : Day is not selected.
3. Current time setting mode indicator
4. DST display(Daylight saving time)
5. AM/PM display
6. Season display
7. Program display
8. Display ON time/day, OFF time/day, ON time width,
OFF time width
9. AM/PM display
10. YEAR display
: It turns ON when set, check, modify, delete yearly
program, set yearly holidays and operate yearly
program.
11. Yearly START/STOP day display
12. Main display
13. Remaining step display
14. Operation mode display
15. Power restore input display
16. Output mode display
17. Year, month, date display
18. Unit of pulse width display
19. Sub-display
20. CHECK key
21. MODE key
22. Operation key
23. Output selection switch
AUTO : Control output according to the set program.
● ON : Output is ON.(Operation)
● OFF : Output is OFF.
Output 1(OUT1) and Output 2(OUT2) are selected
independently.
24. SET key
Program setting and output operation
Output1/Output2 operates according to Program1 and
Program2.
Definitions
● Record : A part of program that controls output operation.
● Step : Basic component of record.
Operation modes
If the operation mode of Program1(Program2) is set on
pulse mode initially, the pulse mode is xed for additional
programs.
If the operation mode of Program1(Program2) is set on
ON/OFF or cycle mode initially, pulse mode cannot be
used for additional programs.
● Weekly ON/OFF mode
Output operation by ON/OFF set time.
• Min. time setting unit : 1 min.
• It is able to set ON/OFF day separately.
• One record in two Steps(ON day/ON time, OFF day/OFF
time)
● Weekly Cycle mode
Output turns ON for ON time and turns OFF for OFF time.
And the ON/OFF cycle is repeated.
23
24
K-79
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Weekly/Yearly Timer
ON time
ON Time
ON width
Pulse width
(1 to 59sec., 1 to 60min.)
OFF time
OFF width
Weekly setting 1 of Program1
Weekly setting 2 of Program1
Yearly setting 1 of Program1
Program1 mode
● Yearly ON/OFF mode
Output turns ON at ON time on START date and turns OFF
at OFF time on STOP date.
• One record in three steps(START/STOP date, ON/OFF
time)
● Yearly pulse mode
Output turns ON at ON time on START date and turns
OFF at OFF time on STOP time for a specied pulse width
repeatedly.(Pulse width : 1 to 59sec., 1 to 60min.).
• One record in three steps(START/STOP date, ON time,
pulse width)
Program operation
① to ② : Operated by weekly setting 1 of Program 1.
② to ③ : Operated by weekly setting 2 of Program 1.
④ to ⑤ : Operated by weekly setting 1 of Program 1.
⑤ to ⑥ : Operated by yearly setting 1 of Program 1.
(During weekly program operation at 12:00 AM on
START date, the weekly program operation stops, and it
changes to yearly program operation mode. The yearly
program operation stops at 12:00 AM on the next day of
STOP date.)
Display and change of next mode
● The day of next mode in Program1 or Program2 is
displayed on the day indicator, and the time of next mode
is displayed on the lower row of screen. Press +
in RUN mode it is changed from program1 to
program2 or from program2 to program1.
● In ON/OFF operation mode, set ON time and OFF time
to next mode. In Pulse operation mode, set Pulse ON
time to next mode.
Power restore mode
In setting group 2-Level 2(Power restore), select auto [AT]
or normal [NOR] by or key, and press key to set.
Auto [AT] power restore mode
Output(OUT1, OUT2) operates according to program when
power turns on again after power failure.
● Normal [NOR] power restore mode
When power turns on again after power failure, output is
kept OFF and RET.IN ashes on the panel. When power
restore input is detected, RET.IN turns off and output
operates according to program.
• Power restore input
Input contact signal in external "Return input terminals (
to )" by switch or relay, or press key for 3sec. in
RUN mode.
Please use reliable contacts enough to ow 0.1mA of
current at 5VDC when use switch or relay.
Season switching mode
This feature uses for setting seasonal weekly operation
mode.
To operate this mode, save starting month and date,
ending month and date of each season which displays S1,
S2, S3, S4 then set day and time of each season in weekly
program setting. It is also able to operate only in summer
and winter season. (S1: set summer season, S2: set winter
season, S3/S4: do not set)
At the season switching selection LEVEL 2 status in setting
2 group (SEN turns ON, OFF ashes), select ON [ON] by
pressing or key and press key to complete the
season switching.
Be sure that if changing season switching from OFF to ON
or, ON to OFF, the weekly program 1(P1) and the weekly
program 2 (P2) which are set before are deleted.
● ON [ON] mode
Weekly program is switched automatically by season
switching.
• Period setting per season
At the season switching selection LEVEL 2 status in
setting 2 group (SEN ashes, the set season turns ON,
START and STOP turn ON), press key.
Advance to the ashing position of season selection
among S1, S2, S3, S4 by or key and press
key.
After set START month, date per season and press
key.
key is pressed after set STOP month, date per season,
it is advanced to LEVEL1 of period setting per season.
Add or adjust the period setting by key.
● It is disable to use when it is OFF [OFF].
● If season terms are overlapped, these are prioritized in
S4>S3>S2>S1 order.
• Set range for ON/OFF time width
: 1min. to 12 hour 59min.
• One record in 3 steps(ON day/ON time, OFF day/OFF
time, ON time width/OFF time width)
● Weekly pulse mode
Output turns ON at ON time for a specied pulse width.
(Pulse width : 1 to 59sec., 1 to 60min.)
• One record in two steps(ON day/ON time, pulse width)
K-80
LE7M-2
Daylight saving time
To utilize daylight during the summer season, daylight
saving time is adjusted forward one hour from standard
time.
In setting group 2-LEVEL 2(DST turns ON, AT or NOR
ashes.), select Auto [AT] or Normal [NOR] by or key
and press key to set.
Auto[AT] Daylight Saving Time mode
Current time will be faster as an hour when it is started and
slower as an hour when it is nished.
Automatic Daylight Saving Time period setting
Automatic Daylight Saving Time period setting LEVEL 1
of setting group 2. (DST ashes and START and STOP
turn ON.)
Set START date(Month, date) of automatic Daylight
Saving Time mode and press key.
Set START time(AM/PM, Hour) of automatic Daylight
Saving Time mode and press key.
But, the minute will be xed as 00.
Set STOP date(Month, date) of automatic Daylight
Saving Time mode and press key.
Set STOP time(AM/PM, Hour) of automatic Daylight
Saving Time mode and press key. But, the minute
will be xed as 00.
● Normal [NOR] daylight saving time mode
Press key over 3sec. in RUN mode, +1h turns ON
and current time is faster as an hour and +1h turns ON out
or vice versa, when press key over 3sec. again.
Current time setting
(Ex) Set the current time as 10, Mar, 2008, 5:10 PM.
SUN MON TUE WED THU FRI SAT
Advance to the current time setting mode
+ keys are
pressed over 3sec. in
RUN mode, it is advanced
to current time setting of
setting group 2 and clock
will be ashed and tAJ will
be lighted in second display
part, press key.
SUN MON TUE WED THU FRI SAT
Year, month, date setting
Press or key to set
08 (year 2008) and move
the ashing digit to position
month by key.
Press key after press
or key to set date 10.
SUN MON TUE WED THU FRI SAT
Current time(AM, PM) setting
Press or key to select
PM and move the ashing
digit to position hour by
key.
SUN MON TUE WED THU FRI SAT
Current time(Hour, Min.) setting
Press or key to set 5
PM and move the ashing
digit to position min. by
key. Press or key to
set 10min. and press
key and it is returned to
RUN mode when press
key over 3sec.
● It advances to "Current time setting mode" in ON
status and set current time as shown above to by
key.
● Current time is set up to 31, Dec., 2099.
● Check current year/month/date in RUN mode When
key is pressed over 3sec. in RUN mode, it advances to
current year/month/date display. After display current
year/month/ date for 3sec., it returns to RUN mode
displaying current display.
K-81
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Weekly/Yearly Timer
RUN mode RUN mode
SET SET
Press MODE key
for 3sec.
Press MODE key
for 3sec.
Press MODE key
for 3sec. Press MODE + SET key
for 3sec.
(Setting group 1)
1
2
(Setting group 2)
Program1 weekly
programsetting mode
(PROG P1 ashes)
Program1 weekly
program setting
Current time setting mode
(Clock icon ashes)
Power failure return selection mode
(RET ashes,
AT or NOR turns ON)
Season switching selection mode
(SEN ashes,
ON or OFF turns ON)
Period setting for season mode
(SEN ashes, period-set
season turns ON and
START or STOP turns ON)
Daylight saving time mode
(DST ashes,
AT or NOR turns ON)
Automatic[AT] daylight
saving time period
setting mode [DST] ashes,
START or STOP turns ON)
Current time
setting
Power failure
return selection
Season switching
selection
Period setting
per season
Daylight saving
time selection
Automatic daylight
saving time period setting
Program2 weekly
programsetting mode
(PROG P2 ashes)
Program2 weekly
program setting
Program1 Yearly
programsetting mode
(PROG P1, YEAR ash)
Program2 yearly program
setting mode
(PROG P2, YEAR ash)
Program1 weekly program
delete mode
(PROG P1, CLR ash)
Program1 weekly program
delete mode
(PROG P2, CLR ash)
Program1 yearly program
delete mode
(PROG P1, YEAR, CLR
ash)
Program2 yearly program
delete mode
(PROG P2, YEAR, CLR
ash)
Weekly day change mode
(cDY ashes)
Yearly holiday operation mode
(hDY, YEAR ash)
Program1 yearly
program setting
Program2 yearly
program setting
All Program1 weekly
program delete
All Program2 weekly
program delete
All Program1 yearly
program delete
All Program2 yearly
program delete
Standard day,
change day setting
Yearly holiday
operation mode setting
Program setting
Setting group 1 Setting group 2
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
SET SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
● When it advances to setting group 1 in RUN mode,
output (OUT1, OUT2) will be OFF.
● It returns to previous setting group 1 when power of time
switch is ON again in setting group 1.
● When MODE key is pressed in LEVEL2 of setting group 1,
current setting will be canceled and it returns to previous
LEVEL1.
1: Season switching selection is OFF.
2: Automatic switching selection of Daylight Saving Time
is Normal [NOR].
● When it advances to setting group 2 in RUN mode,
output (OUT1, OUT2) will be OFF.
● When power of time switch is ON again in setting group 2,
it returns to previous setting group 1.
● Front MODE key is pressed in LEVEL2 of setting group 2,
it returns to previous LEVEL1.
● When season switching selection is changed from OFF
to ON or ON to OFF, previous set weekly program will be
deleted.
K-82
LE7M-2
SUN MON TUE WED THU FRI SAT
8:00
AM
8:00
AM
8:00
AM
8:00
AM
8:00
AM
6:10
PM
6:10
PM
6:10
PM
6:10
PM
6:10
PM
8:00
AM
8:00
AM
8:00
AM
8:00
AM
8:00
AM
8:00
AM
ON for 10sec.
8:00 AM
Weekly program setting
Weekly ON/OFF mode
(Ex) Output1(OUT1) is ON from Monday to Friday at 8:00
AM and OFF at 6:10 PM.
● Weekly pulse mode
Output2(OUT2) is ON for 10sec. at 8:00AM from monday
to friday during S2 season in case, period of S1, S2, S3,
S4 is set.
Advance to program1(P1) weekly program
setting mode
MODE key is pressed over
3sec. in RUN mode, PROG
P1 ashes and press SET
key.
SUN MON TUE WED THU FRI SAT
Mode type setting
Press SET key in ON/OFF
mode.
SUN MON TUE WED THU FRI SAT
ON day setting
Press key to move the
indicator to monday, it will
be lighted when or key
are pressed and move it to
tuesday by key.
Press SET key after
tuesday, wednesday,
thursday, friday turn ON.
SUN MON TUE WED THU FRI SAT
ON time setting(AM, PM)
key is pressed, move the
ashing to hour position and
select PM by or key
when ON time is afternoon.
SUN MON TUE WED THU FRI SAT
ON time setting(Hour, Min.)
Set 8:00 by or key
and press SET key.
SUN MON TUE WED THU FRI SAT
OFF day setting
Press SET key to check
ON/OFF day.
SUN MON TUE WED THU FRI SAT
OFF time setting(AM, PM)
Select PM by or key
and move the ashing to
hour position by key.
SUN MON TUE WED THU FRI SAT
OFF time setting(Hour, Min.)
Move the ashing to minute
position after set 6:00 by
or key and set the minute
as 10 and press SET key.
SUN MON TUE WED THU FRI SAT
Complete to set
Press SET key to set
additional program.
SUN MON TUE WED THU FRI SAT
Program2(P2) advance to weekly program
setting mode
MODE key is pressed for
3sec.in RUN mode, PROG
P1 is ashed and press
MODE key again, PROG P2
ashes and press SET key.
SUN MON TUE WED THU FRI SAT
Mode type setting
Press or key when
ON /OFF ashes, Pulse
ashes and press SET
key.
SUN MON TUE WED THU FRI SAT
Season selection
Press or key to select
season S2 and press SET
key.
SUN MON TUE WED THU FRI SAT
SUN MON TUE WED THU FRI SAT
K-83
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Weekly/Yearly Timer
ON day setting
Press key to move the
indicator to Monday, it will
be lighted when or key
is pressed and move it to
Tuesday by key.
Press SET key after light
Tuesday, Wednesday,
Thursday and Friday.
SUN MON TUE WED THU FRI SAT
Press key, move the
ashing to hour position
and select PM by or
ON time setting(AM, PM)
SUN MON TUE WED THU FRI SAT
Set 8:00 by or key
and press SET key.
ON time setting(Hour, Min.)
SUN MON TUE WED THU FRI SAT
Press or key to select
pulse duration as 10s and
press SET key.
Pulse width setting
SUN MON TUE WED THU FRI SAT
Press SET key to set
additional program.
Complete to set
SUN MON TUE WED THU FRI SAT
6:00 AM
Start Cycle mode
5:30
PM
ON for 10min.
OFF for 5min.
● Weekly cycle mode
(Ex) Output1(OUT1) is ON for 10min and OFF for 5min from
monday 6:00AM to saturday 5:30PM.
SUN MON TUE WED THU FRI
SAT
Advance to program1(P1) weekly program
setting mode
In RUN mode, press MODE
key for 3 sec. and PROG
P1 ashes. Press SET key.
SUN MON TUE WED THU FRI SAT
③ to ⑧
Refer to ③ to ⑧ of "●Weekly ON/OFF mode" to set ON
day, ON time, OFF day and OFF time.
Mode type setting
Press or key when
ON/OFF ashes, CYCLE
ashes and press SET key.
SUN MON TUE WED THU FRI SAT
ON time width setting
Press key to move the
ashing to minute position
and set as 10min. by or
key and press SET key
SUN MON TUE WED THU FRI SAT
OFF time width setting
Press key to move the
ashing to minute position
and set as 5min. by or
key and press SET key.
SUN MON TUE WED THU FRI SAT
Complete to set
Press SET key to set
additional program.
SUN MON TUE WED THU FRI SAT
K-84
LE7M-2
Yearly holiday mode
It operates to off the output without program adjustment
during previously set yearly holiday period available from
present year to 31, Dec. of the next year.
Designate the start date of yearly holiday and year of end
date as every year [--] to repeat the holiday mode for
specied in every year.
● Setting example
Set every year 5, May to off the output(OUT1, OUT2).
Advance to weekly day change mode
Press MODE key over 3sec.
to move to the setting
group1 in RUN mode and
press it repeatedly until cDY
is ashed in second display
part and press SET key.
SUN MON TUE WED THU FRI SAT
Press key until month
position ashes and set
May by or key and
press key until date posi-
tion ashes. Press SET key
after set 5th by key.
Start date of yearly holiday setting
SUN MON TUE WED THU FRI SAT
The ashing is moved to
month position directly and
press or key to set
May and press key until
date position ashes.
Press SET key after set 5th
by or key.
End date of yearly holiday setting
SUN MON TUE WED THU FRI SAT
Press MODE key to nish the
additional yearly holiday
setting and press SET key
to set .
It is able to set yearly
holiday up to 12 times.
Complete to yearly holiday
SUN MON TUE WED THU FRI SAT
Standard day selection
Press key to move the
indicator to saturday and
press SET key. after select
saturday as standard day
(Sat turns ON) by or
key.
SUN MON TUE WED THU FRI SAT
Change day selection
Press key to move the
indicator to monday and
select monday to change
(Mon turns ON) by or
key and repeat the
procedure to select tuesday
to change (Tue turns ON)
and press SET key to
complete.
SUN MON TUE WED THU FRI SAT
Advance to yearly holiday mode
Press MODE key over 3sec.
to move to the setting
group1 in RUN mode and
press it repeatedly until hDY
ashes in second display
part and press SET key.
SUN MON TUE WED THU FRI SAT
Yearly holiday No. display
Press SET key after check
yearly holiday No.
SUN MON TUE WED THU FRI SAT
Weekly day change
It operates when the specied day mode is required
to install in other day from the set day and it returns to
previous program setting automatically when it is nished.
It is applied to program1(P1) and program2(P2).
● Weekly day change cancellation
Change current year, month, date in current time setting
mode
Change standard day
Delete all program in program1(P1) and program2 (P2)
Season switching
● Setting example
Output1(OUT1) is ON in Saturday at 9:00AM and OFF at
12:00PM and it is ON 8:30AM and OFF at 6:00PM from
Monday to Friday and the mode of Monday and Tuesday is
operated temporarily as Saturday(standard) program.
K-85
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Weekly/Yearly Timer
Mode type setting
or key is pressed when
ON/OFF ashes to set
pulse mode and press SET
key.
SUN MON TUE WED THU FRI SAT
Start date setting
Press or key twice to
set 08(year 2008) and move
to month position by key.
Set Oct. by or key and
move to date position by
key and press SET key
after set 2nd by or key.
SUN MON TUE WED THU FRI SAT
End date setting
The ashing is moved to
month position directly by
key and set 4th by or
key after move it to date
position by key, then
press SET key.
SUN MON TUE WED THU FRI SAT
End date setting
The ashing is moved to
month position directly and
press or key to set
April and press or key
until date position ashes.
Press key after set 7th by
SET key.
SUN MON TUE WED THU FRI SAT
ON time setting(AM, PM)
key is pressed, move the
ashing to hour position
and select PM by or key
when ON time is afternoon.
SUN MON TUE WED THU FRI SAT
ON time setting(Hour, Minute)
Press or key to set 9
and press SET key after
check 00min.
SUN MON TUE WED THU FRI SAT
OFF time setting(AM, PM)
Select PM by or key
and move the ashing to
hour position by key.
SUN MON TUE WED THU FRI SAT
OFF time setting(Hour, Minute)
Move the ashing to minute
position after set 5:00 by
or
key and set the minute
as 10
and press SET key.
SUN MON TUE WED THU FRI SAT
Complete to set
Press SET key to set ad-
ditional program.
SUN MON TUE WED THU FRI SAT
2, Oct 3, Oct 4, Oct
8:00
AM
8:00
AM
8:00
AM
ON for 5sec.
10:00AM
● Yearly pulse mode
(Ex)Output2(OUT2) is ON from 2, Oct, 2008 to 4, Oct, 2008
at 10:00AM and OFF after 5sec. (Present is 2007.)
Advance to program2(P2) yearly program
setting mode
MODE key is pressed for
3sec.in RUN mode, PROG
P1 is ashed and press
MODE key again, PROG P2
YEAR is ashed and press
SET key.
SUN MON TUE WED THU FRI SAT
Yearly program setting
● Yearly ON/OFF mode
(Ex) Output1(OUT1) is ON from every 5, Apr to 7, Apr at
9:00AM and OFF 5:10PM.
Advance to program1(P1) yearly program
setting mode
Press MODE key for 3sec.
in RUN mode, PROG P1 is
ashed and press MODE key
3 times more until PROG
P2 YEAR ashes and press
SET key.
SUN MON TUE WED THU FRI SAT
Mode type setting
Press SET key when ON/
OFF ashes.
SUN MON TUE WED THU FRI SAT
Start date setting
Press key until month po-
sition ashes and set April
by or key and press
key until date position
ashes. Press SET key after
set 5th by or key.
SUN MON TUE WED THU FRI SAT
K-86
LE7M-2
RUN mode
Program1 Yearly program
record No.1 [r01]
setting check
Program1 Yearly program
record No.1
[r01]
setting
modify and delete
Program1 Yearly program
record No.2
[r02]
setting
modify and delete
Program2 Yearly program
record No.1
[r01]
setting
modify and delete
Program1 Yearly program
record No.2 [r02]
setting check
Program2 Yearly program
record No.1 [r01]
setting check
CHECK
CHECK
CHECK
Yearly program check, modify and delete
YEAR turns ON when check, modify or delete yearly
program.
● If any key is untouched for 60sec, it is returned to RUN
mode in weekly or yearly program check.
● In weekly or yearly program check, it controls output
according to program setting and output is OFF in
modify or delete mode.
● When MODE key is pressed in weekly or yearly
programrecord modify, delete stand by or delete mode,
current work is cancelled and it is returned to check
mode.
● Weekly or yearly program record modify and delete
(1) Program record modify
When press SET key over 3sec. in program check, EDT
ashes in second display part, press SET key.
It returns to check mode when nish the modify same
as the above procedure.
(2) Program record delete
When press SET key over 3sec. in program check, EDT
ashes in second display part, press or key until
CLR ashes in second display part and press SET key.
Press CLR key over 3sec. when SET turns ON in second
display part, it returns to program check.
RUN mode
Program1 weekly program
record No.1 [r01]
setting check
Program1 weekly program
record No.1
[r01]
setting
modify and delete
Program1 weekly program
record No.2
[r02]
setting
modify and delete
Program2 weekly program
record No.1
[r01]
setting
modify and delete
Program1 weekly program
record No.2 [r02]
setting check
Program2 weekly program
record No.1 [r01]
setting check
Program check, modify and delete
Press CHECK
key for 1sec.
CHECK
CHECK
CHECK
Weekly program check, modify and delete
Press
MODE
key
for 3sec.
Press SET
key for 3sec.
Press SET
key for 3sec.
Press SET
key for 3sec.
Press CHECK
key for 1sec.
Press
MODE
key
for 3sec.
Press SET
key for 3sec.
Press SET
key for 3sec.
Press SET
key for 3sec.
It is able to set year of start/end date in yearly program
setting up to 2 years later from the present year.
key is pressed, move the
ashing to hour position and
select PM by or key
when ON time is afternoon.
ON time setting(AM, PM)
SUN MON TUE WED THU FRI SAT
Complete to set
Press SET key to set
additional program.
SUN MON TUE WED THU FRI SAT
Pulse width setting
Press or key 4 times
to select pulse width as 5s
and press SET key.
SUN MON TUE WED THU FRI SAT
ON time setting(Hour, Minute)
Press or key twice to
set 10 and press SET key
after check 00min.
SUN MON TUE WED THU FRI SAT