G 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2003 TELEDYNE RELAYS
G\032003\Q1
SURGE CURRENT
Figure 4 — G relays output current
ENVIRONMENTAL SPECIFICATION
Min Max Units
Operating Temperature –40 100 °C
Storage Temperature –40 100 °C
Input-Output Isolation 4000 Vrms
Output-Case Isolation 4000 Vrms
Rated Impulse Voltage 4000 Vi
THERMAL CHARACTERISTICS
Figure 5 — G relays output current
NOTES:
1. Maximum voltage limited by MOV.
2. Electrical specifications at 25°C unless otherwise specified.
3. For 800Hz applications, contact factory.
4. For additional/custom options, contact factory.
Series G
OUTPUT (LOAD) SPECIFICATION
Min Max Units
Operating Range (See Note 1) 12 320 Vrms
MOV Clamping Voltage @ 1mA 520 V
Output Current Range .001 12 Arms
Maximum Surge Current Rating (Non-Repetitive)
See Figure 4 260 A
On-State Voltage Drop 0.75(Ie)+0.02(Ie)2V
Zero-Cross Window (Typical)
G24R R NA
G24D D ±12 Vac
Off-State Leakage Current (60Hz) 0.1 mA
Turn-On Time (60 Hz)
FS24R 0.1 ms
FS24D 8.3 ms
Turn-Off Time (60 Hz) 8.3 ms
Off-State dv/dt 500 V/µs
Maximum di/dt (Non-Repetitive) 50 A/µs
Operating Frequency Range 0.1 440 Hz
I2t for Match Fusing (<8.3ms) 340 A2S
Thermal Resistance Junction to Case 5.6 °C/W
1100.10.01
0
50
100
150
200
250
t(s)
Apeak
Repetitive with initial Tj = 70°C
Non-Repetitive
20
15
10
5
0
Ambient Temperature (°C)
Load Current (Arms)
1.2K/W heat sink
2.6K/W heat sink
4K/W heat sink
0102030405060708090100
Figure 3 — G relays
TYPICAL APPLICATION
Control
12-30 Vdc
Line protection
12-280 Vac
–
+
• 1-2 can be changed
• SSR must be mounted on a heat sink
LOAD
1~
2~
4–
3+