C1300 PXO
Vectron International · www.vectron.com
v.2009-09-15-05 · page 1 of 4 SEM
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
Vectron Asia Pacific Sales Office
Unit 3119 31st Floor, Jin Mao Tower, 88
Century Boulevard, Shanghai,
P.R. China 200120
+86 21 28909740 tel.
+86 21 28909240 fax
Frequency Range 1 to 800 MHz (ACMOS and TTL outputs
available up to 125 MHz. LVPECL and LVDS
output frequencies above 220 MHz are achieved
through the use of a PLL multiplier.)
Standard Frequencies 19.44, 32.768, 44.736, 51.84, 77.76, 155.52, 622.08 MHz
Frequency Stabilities
1
Parameter Min Typ Max Units Condition Ordering Code
5
Operating temperature range -100 +100 ppm 0 … +70°C C104
(referenced to +25°C) -50 +50 ppm 0 … +70°C
C505
-25 +25 ppm 0 … +70°C
C255
-15 +15 ppm 0 … +70°C
C155
-100 +100 ppm -40 … +85°C F104
-50 +50 ppm -40 … +85°C F505
-25 +25 ppm -40 … +85°C F255
-100 +100 ppm -55 … +125°C M104
-50 +50 ppm -55 … +125°C M505
Initial accuracy (do not use with -15 +15 ppm @ 25°C
T155
overall tolerance code below) -25 +25 ppm @ 25°C
T255
-50 +50 ppm @ 25°C
T505
-100 +100 ppm @ 25°C
T104
Parameter
Min Typ Max Units Condition Ordering Code
5
Overall tolerance (includes operating -100 +100 ppm 0 … +70°C TC104
temperature and initial accuracy)
7
-50 +50 ppm 0 … +70°C TC505
-25 +25 ppm 0 … +70°C TC255
-20 +20 ppm 0 … +70°C TC205
-100 +100 ppm -40 … +85°C TF104
-50 +50 ppm -40 … +85°C TF505
-25 +25 ppm -40 … +85°C TF255
-100 +100 ppm -55 … +125°C TM104
-65 +65 ppm -55 … +125°C TM605
Additional stability parameters:
vs. Supply voltage change
vs. Load change
vs. Aging / 1st year
vs. Aging / year (following years)
-2
-1
-3
-1
+2
+1
+3
+1
ppm
ppm
ppm
ppm
V
S
± 5%
Load ± 5%
Supply Voltage (Vs)
Parameter Min Typ Max Units Condition Ordering Code
5
Supply voltage 4.75 5.0 5.25 VDC SV050
Current consumption 15 mA ACMOS or TTL 1.0 to 23.9 MHZ
(+5 VDC) 20 mA ACMOS or TTL 24 to 49.9 MHz
40 mA ACMOS or TTL 50 to 125.00 MHz
Supply voltage 3.135 3.3 3.465 VDC SV033
Supply voltage 2.375 2.5 2.625 VDC SV025
Current consumption 6 mA ACMOS 1.0 to 14.90 MHZ
(+3.3 VDC or +2.5 VDC) 8 mA ACMOS 15.0 to 39.9 MHz
12 mA ACMOS 40.0 to 59.9 MHz
16 mA ACMOS 60.0 to 84.9 MHz
40 mA ACMOS 85.0 to 125.0 MHz
75 mA LVPECL or LVDS No load <200 MHz
Typical Applications Features
Military Systems 9X14 J Leaded Surface Mount Package
Avionics and Instrumentation Reflow Process Compatible
Test Equipment ACMOS, TTL, LVPECL and LVDS
Medical Equipment MIL-PRF-55310 Class B Screening (optional)
Military Operating Temperature Range (optional)