Slim Incremental 50-mm-dia. Rotary Encoder E6C2-C CSM_E6C2-C_DS_E_6_1 General-purpose Encoder with External Diameter of 50 mm * Incremental model * External diameter of 50 mm. * Resolution of up to 2,000 ppr. * IP64 (improved oil-proof construction with sealed bearings) * Side or back connections are possible. Pre-wired Models with cable connected at an angle. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Be sure to read Safety Precautions on page 4. Ordering Information Encoders [Refer to Dimensions on page 4.] Power supply voltage Output configuration 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600 Open-collector output (NPN) 5 to 24 VDC 12 to 24 VDC Resolution (pulses/rotation) 720, 800, 1,000, 1,024, 1,200, 1,500, 1,800, 2,000 100, 200, 360, 500, 600 Open-collector output (PNP) Model E6C2-CWZ6C (resolution) 2M Example: E6C2-CWZ6C 10P/R 2M E6C2-CWZ5B (resolution) 2M Example: E6C2-CWZ5B 100P/R 2M 1,000, 2,000 5 to 12 VDC Voltage output 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600 E6C2-CWZ3E (resolution) 2M Example: E6C2-CWZ3E 10P/R 2M 720, 800, 1,000, 1,024, 1,200, 1,500, 1,800, 2,000 5 VDC Line-driver output 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600 E6C2-CWZ1X (resolution) 2M Example: E6C2-CWZ1X 10P/R 2M 720, 800, 1,000, 1,024, 1,200, 1,500, 1,800, 2,000 Accessories (Order Separately) [Refer to Dimensions on Rotary Encoder Accessories.] Name Couplings Flanges Servo Mounting Bracket Model Remarks E69-C06B --- E69-C68B Different end diameter E69-C610B Different end diameter E69-C06M Metal construction E69-FCA --- E69-FCA02 E69-2 Servo Mounting Bracket provided. E69-2 Provided with E69-FCA02 Flange. Refer to Accessories for details. 1 E6C2-C Ratings and Specifications Item Model E6C2-CWZ6C E6C2-CWZ5B E6C2-CWZ3E 5 VDC -5% to 12 VDC +10%, ripple (p-p): 5% max. E6C2-CWZ1X Power supply voltage 5 VDC -5% to 24 VDC +15%, ripple (p-p): 5% max. 12 VDC -10% to 24 VDC +15%, ripple (p-p): 5% max. Current consumption*1 80 mA max. 100 mA max. Resolution (pulses/rotation) 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600, 720, 800, 1,000, 1,024, 1,200, 1,500, 1,800, 2,000 100, 200, 360, 500, 600, 1,000, 2,000 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600, 720, 800, 1,000, 1,024, 1,200, 1,500, 1,800, 2,000 Output phases Phases A, B, and Z Output configuration NPN open-collector output PNP open-collector output Voltage output (NPN output) Line driver output*2 AM26LS31 equivalent Output voltage: High level: IO = -20 mA Low level: IS = 20 mA Output voltage: VO = 2.5 V min. VS = 0.5 V max. 160 mA max. Phases A, A, B, B, Z, and Z Output capacity Applied voltage: 30 VDC max. Sink current: 35 mA max. Residual voltage: 0.4 V max. (at sink current of 35 mA) Applied voltage: 30 VDC max. Source current: 35 mA max. Residual voltage: 0.4 V max. (at source current of 35 mA) Output resistance: 2 k Output current: 20 mA max. Residual voltage: 0.4 V max. (at sink current of 20 mA) Maximum response frequency*3 100 kHz 50 kHz 100 kHz Phase difference between outputs 9045 between A and B (1/4 T 1/8 T) Rise and fall times of output 1 s max. (Control output voltage: 5 V, Load resistance: 1 k, Cable length: 2 m) Starting torque 10 mN*m max. 1 s max. (Cable length: 2 m, Sink current: 10 mA) 0.1 s max. (Cable length: 2 m, IO = -20 mA, IS = 20 mA) 1x10-6 kg*m2 max.; 3 x 10-7 kg*m2 max. at 600 P/R max. Moment of inertia Shaft loading 5 VDC 5%, ripple (p-p): 5% max. Radial 50 N Thrust 30 N Maximum permissible speed 6,000 r/min Protection circuits Power supply reverse polarity protection, Load short-circuit protection Ambient temperature range Operating: -10 to 70C (with no icing), Storage: -25 to 85C (with no icing) Ambient humidity range Operating/Storage: 35% to 85% (with no condensation) Insulation resistance 20 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance Destruction: 10 to 500 Hz, 150 m/s2 or 2-mm double amplitude for 11 min 3 times each in X, Y, and Z directions Shock resistance Destruction: 1,000 m/s2 3 times each in X, Y, and Z directions Degree of protection IEC 60529 IP64, in-house standards: oilproof Connection method Pre-wired Models (Standard cable length: 2 m) Material Case: Zinc alloy, Main unit: Aluminum, Shaft: SUS420J2 Weight (packed state) Approx. 400 g Accessories Instruction manual Note: Coupling, mounting bracket and hex-head spanner are sold separately. --- Note: Origin Indication The following illustration shows the relationship between phase Z and the origin. Set cut face D to the phase Z origin as shown in the illustration. Phase Z origin Origin Cut face D 120 120 38 dia. *1. An inrush current of approximately 9 A will flow for approximately 0.3 ms when the power is turned ON. *2. The line driver output is a data transmission circuit compatible with RS-422A and long-distance transmission is possible with a twisted-pair cable.(AM26LS31 equivalent) *3. The maximum electrical response speed is determined by the resolution and maximum response frequency as follows: Maximum response frequency x 60 Maximum electrical response speed (rpm) = Resolution This means that the E6C2-C Rotary Encoder will not operate electrically if its speed exceeds the maximum electrical response speed. 2 E6C2-C I/O Circuit Diagrams Model/Output Circuits Output mode Connection E6C2-CWZ6C 5 VDC -5% to 24 VDC +15% Black, white, orange Output signal E6C2-C main circuit 3.3 NPN transistor 35 mA max. 30 VDC max. (Black: phase A, White: phase B, Orange: phase Z) Blue E6C2-CWZ6C NPN Open-collector Output Model E6C2-CWZ5B PNP Open-collector Output Model Direction of rotation: CW (as viewed from end of shaft) 0V Shield T(360) GND Phase A Phase B E6C2-CWZ5B Phase Z Brown 12 VDC 24 VDC 3.3 35 mA max. E6C2-C main circuit PNP transistor -10% to +15% Black, white, orange Blue Output signal (Black: phase A, White: phase B, Orange: phase CW ON OFF ON OFF ON OFF Direction of rotation: CCW (as viewed from end of shaft) T(360) Phase A ON OFF ON Phase B OFF 1/41/8T(9045) ON Phase Z OFF Note: Phase A is 1/4 T 1/8 T faster than phase B. CCW 1/41/8T (9045) Note: Phase A is 1/4 T 1/8 T slower than phase B. The ONs in the above timing chart mean that the output transistor is ON and the OFFs mean that the output transistor is OFF. Brown Black White Orange 0V Shield Color GND Blue Terminal Power supply (+Vcc) Output phase A Output phase B Output phase Z 0 V (common) E6C2-CWZ3E E6C2-CWZ3E Voltage Output Model Brown 2 k 5 VDC -5% to 12 VDC +10% Black, white, orange E6C2-C main circuit NPN transistor 3.3 Direction of rotation: CW (as viewed from end of shaft) Output signal (Black: phase A, White: phase B, Orange: phase Z) T(360) H L H Phase B L H Phase Z L Phase A 20mA max. Blue Shield 0V GND Direction of rotation: CCW (as viewed from end of shaft) CW T(360) H L H Phase B L 1/41/8T (9045) H Phase Z L CCW Phase A Note: Phase A is 1/4 T 1/8 T faster than phase B. 1/41/8T (9045) Note: Phase A is 1/4 T 1/8 T slower than phase B. "H" and "L" in the diagrams are the output voltage levels of phases A, B, and Z. E6C2-CWZ1X Color E6C2-CWZ1X Line Driver Output Model Brown 5 VDC 5% Black, white, orange E6C2-C main circuit AM26 LS31 equivalent Non-reversed output (Black: phase A, White: phase B, Black, White, Orange Orange: phase Z) Direction of rotation: CW (as viewed from end of shaft) T(360) (with red stripe) Reversed output (Black/red: Phase A, White/red: Phase B, Orange/red: Phase Z) Blue Shield 0V GND Phase A Phase Z CW H L H Phase B L H Phase Z L H Phase A L H Phase B L Brown Direction of rotation: CCW (as viewed from end of shaft) T(360) Phase A Phase B 1/41/8T (9045) Phase Z H L Note: Phase A is 1/4 T 1/8 T faster than phase B. Phase A Phase B Phase Z CCW H L H L H 1/41/8T (9045) L H L H L H L Terminal Power supply (+Vcc) Output phase A Output phase B Output phase Z Black White Orange Black/red Output phase A stripes White/red Output phase B stripes Orange/ Output phase Z red stripes Blue 0 V (common) Note: Receiver: AM26LS32 equivalent Note: Phase A is 1/4 T 1/8 T slower than phase B. "H" and "L" in the diagrams are the output voltage levels of phases A, B, and Z. Note: 1. The shielded cable outer core (shield) is not connected to the inner area or to the case. 2. The phase A, phase B, and phase Z circuits are all identical. 3. Normally, connect GND to 0 V or to an external ground. 3 E6C2-C Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Precautions for Correct Use Do not use the Encoder under ambient conditions that exceed the ratings. Wiring Cable Extension Characteristics * When the cable length is extended, the output waveform startup time is lengthened and it affects the phase difference characteristics of phases A and B. Conditions will change according to frequency, noise, and other factors. As a guideline, use a cable length of 10 m* or less. If the cable must be more than 2 m, use a Model with a Line-driver Output (max. length for linedriver output: 100 m). * The output waveform startup time changes not only according to the length of the cable, but also according to the load resistance and the cable type. * Extending the cable length not only changes the startup time, but also increases the output residual voltage. Connection Spurious pulses may be generated when power is turned ON and OFF. Wait at least 0.1 s after turning ON the power to the Encoder before using the connected device, and stop using the connected device at least 0.1 s before turning OFF the power to the Encoder. Also, turn ON the power to the load only after turning ON the power to the Encoder. * Recommended Cable Conductor cross section: 0.2 mm2 Spiral shield Conductor resistance: 92 /km max. (20C) Insulation resistance: 5 /km min. (20C) (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified. Encoder E6C2-CWZ@@ (60) Origin of Phase Z Three, M4 holes; Depth: 7 mm 1.6 15 10 5 40 (6.59) 0 6 -0.021 dia. 1 0 25 -0.021 50 dia. dia. 120 120 38 dia. 5-dia. oil-resistant PVC-insulated shielded cable with 5 conductors (line driver: 8 conductors) (Conductor cross section: 0.2 mm2, Insulator diameter: 1.0 mm), Standard length: 2 m Accessories (Order Separately) Couplings E69-C06B E69-C68B E69-C610B E69-C06M Flanges E69-FCA E69-FCA02 Servo Mounting Bracket E69-2 (Three brackets in a set.) Refer to Accessories for details. 4 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2014.1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2014 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: E6C2-CWZ3E 1000P/R 2M E6C2-CWZ3E 100P/R 2M E6C2-CWZ3E 10P/R 2M E6C2-CWZ3E 1200P/R 2M E6C2CWZ3E 1500P/R 2M E6C2-CWZ3E 2000P/R 2M E6C2-CWZ3E 200P/R 2M E6C2-CWZ3E 20P/R 2M E6C2-CWZ3E 300P/R 2M E6C2-CWZ3E 30P/R 2M E6C2-CWZ3E 360P/R 2M E6C2-CWZ3E 400P/R 2M E6C2-CWZ3E 40P/R 2M E6C2-CWZ3E 500P/R 2M E6C2-CWZ3E 50P/R 2M E6C2-CWZ3E 600P/R 2M E6C2-CWZ3E 60P/R 2M E6C2CWZ5B 100P/R 2M E6C2-CWZ5B 2000P/R 2M E6C2-CWZ5B 360P/R 2M E6C2-CWZ5B 500P/R 2M E6C2-CWZ5B 600P/R 2M E6C2-CWZ6C 1000P/R 2M E6C2-CWZ6C 100P/R 2M E6C2-CWZ6C 1024P/R 2M E6C2-CWZ6C 1200P/R 2M E6C2-CWZ6C 1500P/R 2M E6C2-CWZ6C 1800P/R 2M E6C2-CWZ6C 200P/R 2M E6C2-CWZ6C 20P/R 2M E6C2-CWZ6C 30P/R 2M E6C2-CWZ6C 400P/R 2M E6C2-CWZ6C 40P/R 2M E6C2-CWZ6C 500P/R 2M E6C2CWZ6C 60P/R 2M E6C2-CWZ6C 720P/R E6C2-CWZ6C 800P/R 2M E6C2-CWZ1X 1024P/R 2M