DC-DC Converters Bus Converter . Power Module Value-added Type SNDHS50A Ordering information SNDH S 1 2 50 3 A 05 4 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 A : DC60-160V 5 Output voltage 6 Optional C : with Coating R : with Remote ON/OFF R Please refer to Instruction manual 7. MODEL SNDHS50A05 SNDHS50A12 SNDHS50A15 SNDHS50A24 MAX OUTPUT WATTAGE[W] 50.0 50.4 51.0 50.4 DC OUTPUT 5V 10A 12V 4.2A 15V 3.4A 24V 2.1A MODEL SNDHS50A05 SNDHS50A12 SNDHS50A15 SNDHS50A24 VOLTAGE[V] DC60 - 160 SPECIFICATIONS INPUT CURRENT[A] *1 0.55typ 0.55typ 0.55typ 0.55typ EFFICIENCY[%] *1 83.0typ 85.0typ 85.0typ 85.0typ VOLTAGE[V] 5 12 15 24 CURRENT[A] 10 4.2 3.4 2.1 LINE REGULATION[mV] 10max 24max 30max 48max LOAD REGULATION[mV] 150max 100max 100max 100max 0 to +95C *2 80max 120max 120max 120max -20 to 0C *2 120max 150max 150max 150max 0 to 15% Load*2 160max 240max 240max 240max 0 to +95C *2 160max 200max 200max 200max -20 to 0C *2 250max 280max 280max 280max 0 to 15% Load*2 300max 300max 300max 300max 0 to +50C 50max 120max 150max 240max -20 to +95C 100max 240max 300max 480max 40max 60max 90max RIPPLE[mVp-p] OUTPUT RIPPLE NOISE[mVp-p] TEMPERATURE REGULATION[mV] DRIFT[mV] *3 200max (DCIN 110V, Io=100%) START-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 20max *4 OUTPUT VOLTAGE SETTING[V] 4.50 - 5.50 10.80 - 13.20 13.50 - 16.50 21.60 - 26.40 5.00 - 5.15 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 17.25 - 21.75 27.60 - 34.80 OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically SNDHS PROTECTION OVERVOLTAGE PROTECTION[V] 6.30 - 7.60 13.90 - 17.55 CIRCUIT AND REMOTE SENSING None OTHERS Optional (Required external power source) REMOTE ON/OFF (RC) INPUT-OUTPUT, RC ISOLATION ENVIRONMENT SAFETY OTHERS *1 *2 *3 *4 *5 *6 *5 INPUT-FG AC3,000V 1minute, Cutoff current = 15mA, DC500V 50MW min (2015C) AC2,000V 1minute, Cutoff current = 15mA, DC500V 50MW min (2015C) OUTPUT, RC-FG *5 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (2015C) OUTPUT-RC *5 AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (2015C) OPERATING TEMP.,HUMID.AND ALTITUDE *6 -20 to +95C (Aluminum base plate of the power module), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +95C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis AGENCY APPROVALS UL60950-1, C-UL, EN60950-1 CONDUCTED NOISE (at only DC input) Complies with FCC-A, VCCI-A, CISPR22-A, EN55011-A, EN55022-A CASE SIZE/WEIGHT 61.5X44.5X150mm [2.42X1.75X5.91 inches] (WXHXD) / 270g max COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) At rated input(DC110V) and rated load. Ripple and ripple noise is measured by using measuring board with capacitor of 22mF at 150mm [5.91 inches] from output terminal. Refer to the instruction manual 3.2. Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Refer to the instruction manual 4.6. Applicable when remote control (optional) is added. Refer to the instruction manual 6.2. SNDHS-2 SNDHS50A External view 10 [0.39] 20.75 10 [0.82] [0.39] 4-f4.5 [4-f0.177] Mounting hole Terminal cover M4 8.6 Connector for remote ON/OFF (optional) [0.34] +Vin -Vin FG TB1 [0.66] Voltage adjust [5.23] 132.81 [5.510.02] 139.84 0.5 16.75 CN2 PointB 2 [1.51] TB2 8.7 -Vout 8.6 [0.34] 25.65 10 [0.39] [1.01] 5.08 51.34 0.5 [0.20] [2.020.02] PointA Terminal cover M4 61.5 [2.42] [1.75 max] Power module (DHS50A) 44.5 max [0.2] +Vout [0.34] 38.25 1 5.08 150 [5.91] Name plate Tolerance : 1 [0.04] Weight : 270g max Dimensions in mm, [ ]=inches PCB material/thickness : FR-4 / 1.6mm [0.06] Base plate material/thickness : Alminum / 3.0mm[0.12] Mounting torque : 1.6N-m (16.9kgf-cm) max Component positions and sizes are for your reference if they have no dimensions. Please connect safety ground to the base plate in f4.5 [f0.177] hole. Base plate SNDHS SNDHS-3 DC-DC Converters Bus Converter . Power Module Value-added Type SNDHS100A Ordering information SNDH S 1 2 100 3 A 05 4 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 A : DC60-160V 5 Output voltage 6 Optional C : with Coating R : with Remote ON/OFF R Please refer to Instruction manual 7. MODEL SNDHS100A05 SNDHS100A12 SNDHS100A15 SNDHS100A24 MAX OUTPUT WATTAGE[W] 100.0 100.8 100.5 100.8 DC OUTPUT 5V 20A 12V 8.4A 15V 6.7A 24V 4.2A MODEL SNDHS100A05 SNDHS100A12 SNDHS100A15 SNDHS100A24 VOLTAGE[V] DC60 - 160 SPECIFICATIONS INPUT CURRENT[A] *1 1.1typ 1.1typ 1.1typ 1.1typ EFFICIENCY[%] *1 84.0typ 87.0typ 87.0typ 87.0typ VOLTAGE[V] 5 12 15 24 CURRENT[A] 20 8.4 6.7 4.2 LINE REGULATION[mV] 10max 24max 30max 48max LOAD REGULATION[mV] 150max 100max 100max 100max 0 to +95C *2 80max 120max 120max 120max -20 to 0C *2 120max 150max 150max 150max 0 to 15% Load*2 160max 240max 240max 240max 0 to +95C *2 160max 200max 200max 200max -20 to 0C *2 250max 280max 280max 280max 0 to 15% Load*2 300max 300max 300max 300max 0 to +50C 50max 120max 150max 240max -20 to +95C 100max 240max 300max 480max 40max 60max 90max RIPPLE[mVp-p] OUTPUT RIPPLE NOISE[mVp-p] TEMPERATURE REGULATION[mV] DRIFT[mV] *3 200max (DCIN 110V, Io=100%) START-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 20max *4 OUTPUT VOLTAGE SETTING[V] 4.50 - 5.50 10.80 - 13.20 13.50 - 16.50 21.60 - 26.40 5.00 - 5.15 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 17.25 - 21.75 27.60 - 34.80 OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically SNDHS PROTECTION OVERVOLTAGE PROTECTION[V] 6.30 - 7.60 13.90 - 17.55 CIRCUIT AND REMOTE SENSING None OTHERS Optional (Required external power source) REMOTE ON/OFF (RC) INPUT-OUTPUT, RC ISOLATION ENVIRONMENT SAFETY OTHERS *1 *2 *3 *4 *5 *6 *5 INPUT-FG AC3,000V 1minute, Cutoff current = 15mA, DC500V 50MW min (2015C) AC2,000V 1minute, Cutoff current = 15mA, DC500V 50MW min (2015C) OUTPUT, RC-FG *5 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (2015C) OUTPUT-RC *5 AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (2015C) OPERATING TEMP.,HUMID.AND ALTITUDE *6 -20 to +95C (Aluminum base plate of the power module), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +95C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis AGENCY APPROVALS UL60950-1, C-UL, EN60950-1 CONDUCTED NOISE (at only DC input) Complies with FCC-A, VCCI-A, CISPR22-A, EN55011-A, EN55022-A CASE SIZE/WEIGHT 61.5X44.5X150mm [2.42X1.75X5.91 inches] (WXHXD) / 270g max COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) At rated input(DC110V) and rated load. Ripple and ripple noise is measured by using measuring board with capacitor of 22mF at 150mm [5.91 inches] from output terminal. Refer to the instruction manual 3.2. Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Refer to the instruction manual 4.6. Applicable when remote control (optional) is added. Refer to the instruction manual 6.2. SNDHS-4 SNDHS100A External view 10 [0.39] 20.75 10 [0.82] [0.39] 4-f4.5 [4-f0.177] Mounting hole M4 8.6 Connector for remote ON/OFF (optional) [0.34] +Vin -Vin FG Terminal cover TB1 [0.66] Voltage adjust [5.23] 132.81 [5.510.02] 139.84 0.5 16.75 CN2 PointB 2 [1.51] TB2 -Vout 8.7 [0.2] +Vout 8.6 [0.34] 25.65 10 [0.39] [1.01] 5.08 51.34 0.5 [0.2] [2.020.02] PointA Terminal cover M4 61.5 [2.42] [1.75 max] Power module (DHS100A) 44.5 max [0.34] 38.25 1 5.08 150 [5.91] Name plate Tolerance : 1 [0.04] Weight : 270g max Dimensions in mm, [ ]=inches PCB material/thickness : FR-4 / 1.6mm [0.06] Base plate material/thickness : Alminum / 3.0mm[0.12] Mounting torque : 1.6N-m (16.9kgf-cm) max Component positions and sizes are for your reference if they have no dimensions. Please connect safety ground to the base plate in f4.5 [f0.177] hole. Base plate SNDHS SNDHS-5 DC-DC Converters Bus Converter . Power Module Value-added Type SNDHS200A Ordering information SNDH S 1 2 200 3 A 05 4 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 A : DC60-160V 5 Output voltage 6 Optional C : with Coating R : with Remote ON/OFF R Please refer to Instruction manual 7. MODEL SNDHS200A05 SNDHS200A12 SNDHS200A15 SNDHS200A24 MAX OUTPUT WATTAGE[W] 200.0 200.4 201.0 201.6 DC OUTPUT 5V 40A 12V 16.7A 15V 13.4A 24V 8.4A MODEL SNDHS200A05 SNDHS200A12 SNDHS200A15 SNDHS200A24 VOLTAGE[V] DC60 - 160 SPECIFICATIONS INPUT CURRENT[A] *1 2.1typ 2.1typ 2.1typ 2.1typ EFFICIENCY[%] *1 87.0typ 87.0typ 87.0typ 87.0typ VOLTAGE[V] 5 12 15 24 CURRENT[A] 40 16.7 13.4 8.4 LINE REGULATION[mV] 10max 24max 30max 48max LOAD REGULATION[mV] 150max 100max 100max 100max 0 to +95C *2 80max 120max 120max 120max -20 to 0C *2 120max 150max 150max 150max 0 to 15% Load*2 160max 240max 240max 240max 0 to +95C *2 160max 200max 200max 200max -20 to 0C *2 250max 280max 280max 280max 0 to 15% Load*2 300max 300max 300max 300max 0 to +50C 50max 120max 150max 240max -20 to +95C 100max 240max 300max 480max 40max 60max 90max RIPPLE[mVp-p] OUTPUT RIPPLE NOISE[mVp-p] TEMPERATURE REGULATION[mV] DRIFT[mV] *3 200max (DCIN 110V, Io=100%) START-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 20max *4 OUTPUT VOLTAGE SETTING[V] 4.50 - 5.50 10.80 - 13.20 13.50 - 16.50 21.60 - 26.40 5.00 - 5.15 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 17.25 - 20.25 27.60 - 32.40 OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically SNDHS PROTECTION OVERVOLTAGE PROTECTION[V] 6.30 - 7.60 13.90 - 16.35 CIRCUIT AND REMOTE SENSING Provided OTHERS REMOTE ON/OFF (RC) Optional (Required external power source) INPUT-OUTPUT, RC ISOLATION ENVIRONMENT SAFETY OTHERS *1 *2 *3 *4 *5 *6 *5 INPUT-FG AC3,000V 1minute, Cutoff current = 15mA, DC500V 50MW min (2015C) AC2,000V 1minute, Cutoff current = 15mA, DC500V 50MW min (2015C) OUTPUT, RC-FG *5 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (2015C) OUTPUT-RC *5 AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (2015C) OPERATING TEMP.,HUMID.AND ALTITUDE *6 -20 to +95C (Aluminum base plate of the power module), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +95C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis AGENCY APPROVALS UL60950-1, C-UL, EN60950-1 CONDUCTED NOISE (at only DC input) Complies with FCC-A, VCCI-A, CISPR22-A, EN55011-A, EN55022-A CASE SIZE/WEIGHT 74.2X44.5X150mm [2.92X1.75X5.91 inches](WXHXD) / 390g max COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) At rated input(DC110V) and rated load. Ripple and ripple noise is measured by using measuring board with capacitor of 22mF at 150mm [5.91 inches] from output terminal. Refer to the instruction manual 3.2. Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Refer to the instruction manual 4.6. Applicable when remote control (optional) is added. Refer to the instruction manual 6.2. SNDHS-6 SNDHS200A External view 10 [0.39] 10 27 [1.06] [0.39] 8.6 Connector for remote ON/OFF (optional) M4 [0.34] +Vin -Vin FG [5.27] 133.9 [5.510.02] 1 TB2 -Vout 8.6 M4 [0.34] 22 10 [0.87] [0.39] 10 PointA Terminal cover 10 [0.39] [0.39] 5.08 64.04 0.5 [0.20] [2.520.02] 74.2 [2.92] Power module [1.75 max] (DHS200A) 44.5max 8.35 30.3 [1.19] PointB CN2 CN3 2 4 [0.33] 139.840.5 7 [0.28] +Vout 5.08 Name plate Voltage adjust [0.20] 150 [5.91] TB1 1 Terminal cover 4-f4.5 [4-f0.177] Mounting hole Tolerance : 1 [0.04] Weight : 390g max Dimensions in mm, [ ]=inches PCB material/thickness : FR-4 / 1.6mm [0.06] Base plate material/thickness : Alminum / 3.0mm[0.12] Mounting torque : 1.6N-m (16.9kgf-cm) max Component positions and sizes are for your reference if they have no dimensions. Please connect safety ground to the base plate in f4.5 [f0.177] hole. Base plate SNDHS SNDHS-7 DC-DC Converters Bus Converter . Power Module Value-added Type SNDHS50B Ordering information SNDH S 1 2 50 3 B 05 4 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 B : DC200-400V 5 Output voltage 6 Optional C : with Coating R : with a function not to need external power source R MODEL SNDHS50B03 SNDHS50B05 SNDHS50B12 SNDHS50B15 SNDHS50B24 SNDHS50B28 MAX OUTPUT WATTAGE[W] 33.0 50.0 50.4 51.0 50.4 50.4 DC OUTPUT 3.3V 10A 5V 10A 12V 4.2A 15V 3.4A 24V 2.1A 28V 1.8A MODEL SNDHS50B03 SNDHS50B05 SNDHS50B12 SNDHS50B15 SNDHS50B24 SNDHS50B28 VOLTAGE[V] DC200 - 400 (Prepare another power supply to the RC1 terminal *5) SPECIFICATIONS INPUT CURRENT[A] *1 0.15typ 0.22typ 0.22typ 0.22typ 0.22typ 0.22typ EFFICIENCY[%] *1 76.0typ 79.0typ 82.0typ 82.0typ 82.0typ 82.0typ VOLTAGE[V] 3.3 5 12 15 24 28 CURRENT[A] 10 10 4.2 3.4 2.1 1.8 LINE REGULATION[mV] 10max 10max 24max 30max 48max 56max LOAD REGULATION[mV] 150max 150max 100max 100max 100max 100max 0 to +95C *2 80max 80max 120max 120max 120max 120max -20 to 0C *2 120max 120max 150max 150max 150max 150max 0 to 15% Load*2 160max 160max 240max 240max 240max 240max 0 to +95C *2 160max 160max 200max 200max 200max 200max -20 to 0C *2 250max 250max 280max 280max 280max 280max 0 to 15% Load*2 300max 300max 300max 300max 300max 300max 0 to +50C 35max 50max 120max 150max 240max 280max -20 to +95C 66max 100max 240max 300max 480max 560max 20max 40max 60max 90max 90max RIPPLE[mVp-p] OUTPUT RIPPLE NOISE[mVp-p] TEMPERATURE REGULATION[mV] DRIFT[mV] *3 16max 200max (DCIN 280V, Io=100%) START-UP TIME[ms] 2.97 - 3.63 4.50 - 5.50 10.80 - 13.20 13.50 - 16.50 21.60 - 26.40 25.20 - 30.80 3.30 - 3.40 5.00 - 5.15 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 28.00 - 29.12 PROTECTION OVERVOLTAGE PROTECTION[V] 4.20 - 5.70 6.30 - 7.60 13.90 - 17.55 17.25 - 21.75 CIRCUIT AND REMOTE SENSING None OTHERS REMOTE ON/OFF (RC1) *6 Provided (Logic H : ON, L :OFF) Required external power source 27.60 - 34.80 32.20 - 40.60 OUTPUT VOLTAGE ADJUSTMENT RANGE[V] *4 OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically SNDHS INPUT-OUTPUT, RC2 ISOLATION ENVIRONMENT SAFETY OTHERS *1 *2 *3 *4 *5 *8 INPUT-FG AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) OUTPUT, RC2-FG *8 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (2015C) OUTPUT-RC2 *8 AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (2015C) OPERATING TEMP.,HUMID.AND ALTITUDE *7 -20 to +95C (Aluminum base plate of the power module), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +95C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis AGENCY APPROVALS UL60950-1, C-UL, EN60950-1 CASE SIZE/WEIGHT 61.5X44.5X127mm [2.42X1.75X5.0 inches] (WXHXD) / 220g max COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) At rated input(DC280V) and rated load. Ripple and ripple noise is measured by using measuring board with capacitor of 22mF at 150mm [5.91 inches] from output terminal. Refer to the instruction manual 3.2. Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Refer to the instruction manual 4.6. Refer to the instruction manual 2, 4.4 SNDHS-8 *6 *7 *8 Refer to the instruction manual 4.4 Refer to the instruction manual 6.2 "RC2" is applicable to an option not to need external power source. SNDHS50B External view Connector for remote ON/OFF (optional) 4-f4.5 [4-f0.177] Mounting hole 4 4 2 1 2 1 +Vin -Vin RC1 CN2 CN1 Name plate 1 8.7 CN3 1 2 PointB [0.34] Voltage adjust [1.69] [4.600.02] [0.74] 43 116.84 0.5 2 18.7 TB1 -Vout M4 8.6 PointA Terminal cover [0.34] 26.2 10 [1.03] [0.39] 5.08 51.34 0.5 [0.20] [2.020.02] 61.5 [2.42] [1.75 max] Power module (DHS50B) 44.5 max 5.08 +Vout [0.20] 127 [5.00] CN4 Base plate Tolerance : 1 [0.04] Weight : 220g max Dimensions in mm, [ ]=inches PCB material/thickness : FR-4 / 1.6mm [0.06] Base plate material/thickness : Alminum / 3.0mm[0.12] Screw tightening torque : 1.6N-m (16.9kgf-cm) max Component positions and sizes are for your reference if they have no dimensions. Please connect safety ground to the base plate in f4.5 [f0.177] hole. SNDHS SNDHS-9 DC-DC Converters Bus Converter . Power Module Value-added Type SNDHS100B Ordering information SNDH S 1 2 100 3 B 05 4 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 B : DC200-400V 5 Output voltage 6 Optional C : with Coating R : with a function not to need external power source R MODEL SNDHS100B03 SNDHS100B05 SNDHS100B12 SNDHS100B15 SNDHS100B24 SNDHS100B28 MAX OUTPUT WATTAGE[W] 66.0 100.0 100.8 100.5 100.8 100.8 DC OUTPUT 3.3V 20A 5V 20A 12V 8.4A 15V 6.7A 24V 4.2A 28V 3.6A MODEL SNDHS100B03 SNDHS100B05 SNDHS100B12 SNDHS100B15 SNDHS100B24 SNDHS100B28 VOLTAGE[V] DC200 - 400 (Prepare another power supply to the RC1 terminal *5) SPECIFICATIONS INPUT CURRENT[A] *1 0.30typ 0.44typ 0.42typ 0.42typ 0.42typ 0.42typ EFFICIENCY[%] *1 78.0typ 81.0typ 84.0typ 85.0typ 85.0typ 85.0typ VOLTAGE[V] 3.3 5 12 15 24 28 CURRENT[A] 20 20 8.4 6.7 4.2 3.6 LINE REGULATION[mV] 10max 10max 24max 30max 48max 56max LOAD REGULATION[mV] 150max 150max 100max 100max 100max 100max 0 to +95C *2 80max 80max 120max 120max 120max 120max -20 to 0C *2 120max 120max 150max 150max 150max 150max 0 to 15% Load*2 160max 160max 240max 240max 240max 240max 0 to +95C *2 160max 160max 200max 200max 200max 200max -20 to 0C *2 250max 250max 280max 280max 280max 280max 0 to 15% Load*2 300max 300max 300max 300max 300max 300max 0 to +50C 35max 50max 120max 150max 240max 280max -20 to +95C 66max 100max 240max 300max 480max 560max 20max 40max 60max 90max 90max RIPPLE[mVp-p] OUTPUT RIPPLE NOISE[mVp-p] TEMPERATURE REGULATION[mV] DRIFT[mV] *3 16max 200max (DCIN 280V, Io=100%) START-UP TIME[ms] 2.97 - 3.63 4.50 - 5.50 10.80 - 13.20 13.50 - 16.50 21.60 - 26.40 25.20 - 30.80 3.30 - 3.40 5.00 - 5.15 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 28.00 - 29.12 PROTECTION OVERVOLTAGE PROTECTION[V] 4.20 - 5.70 6.30 - 7.60 13.90 - 17.55 17.25 - 21.75 CIRCUIT AND REMOTE SENSING None OTHERS REMOTE ON/OFF (RC1) *6 Provided (Logic H : ON, L :OFF) Required external power source 27.60 - 34.80 32.20 - 40.60 OUTPUT VOLTAGE ADJUSTMENT RANGE[V] *4 OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically SNDHS INPUT-OUTPUT, RC2 ISOLATION ENVIRONMENT SAFETY OTHERS *1 *2 *3 *4 *5 *8 INPUT-FG AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) OUTPUT, RC2-FG *8 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (2015C) OUTPUT-RC2 *8 AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (2015C) OPERATING TEMP.,HUMID.AND ALTITUDE *7 -20 to +95C (Aluminum base plate of the power module), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +95C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis AGENCY APPROVALS UL60950-1, C-UL, EN60950-1 CASE SIZE/WEIGHT 61.5X44.5X127mm [2.42X1.75X5.0 inches] (WXHXD) / 220g max COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) At rated input(DC280V) and rated load. Ripple and ripple noise is measured by using measuring board with capacitor of 22mF at 150mm [5.91 inches] from output terminal. Refer to the instruction manual 3.2. Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Refer to the instruction manual 4.6. Refer to the instruction manual 2, 4.4 SNDHS-10 *6 *7 *8 Refer to the instruction manual 4.4 Refer to the instruction manual 6.2 "RC2" is applicable to an option not to need external power source. SNDHS100B External view Connector for remote ON/OFF (optional) 4-f4.5 [4-f0.177] Mounting hole 4 4 2 1 2 1 +Vin -Vin RC1 CN2 CN1 Name plate 1 8.7 CN3 1 2 PointB [0.34] [1.69] [4.600.02] [0.74] Voltage adjust 43 116.84 0.5 18.7 TB1 -Vout M4 8.6 PointA Terminal cover [0.34] 26.2 10 [1.03] [0.39] 5.08 51.34 0.5 [0.20] [2.020.02] 61.5 [2.42] [1.75 max] Power module (DHS100B) 44.5 max 5.08 +Vout [0.20] 127 [5.00] CN4 2 Base plate Tolerance : 1 [0.04] Weight : 220g max Dimensions in mm, [ ]=inches PCB material/thickness : FR-4 / 1.6mm [0.06] Base plate material/thickness : Alminum / 3.0mm[0.12] Screw tightening torque : 1.6N-m (16.9kgf-cm) max Component positions and sizes are for your reference if they have no dimensions. Please connect safety ground to the base plate in f4.5 [f0.177] hole. SNDHS SNDHS-11 DC-DC Converters Bus Converter . Power Module Value-added Type Ordering information SNDHS250B SNDH S 1 2 250 3 B 05 4 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 B : DC200-400V 5 Output voltage 6 Optional C : with Coating R : with a function not to need external power source R MODEL SNDHS250B03 SNDHS250B05 SNDHS250B07 SNDHS250B12 SNDHS250B15 SNDHS250B24 SNDHS250B28 SNDHS250B48 MAX OUTPUT WATTAGE[W] 165.0 250.0 247.5 252.0 247.5 252.0 252.0 249.6 DC OUTPUT 3.3V 50A 5V 50A 7.5V 33A 12V 21A 15V 16.5A 24V 10.5A 28V 9.0A 48V 5.2A SPECIFICATIONS INPUT MODEL SNDHS250B03 SNDHS250B05 SNDHS250B07 SNDHS250B12 SNDHS250B15 SNDHS250B24 SNDHS250B28 SNDHS250B48 VOLTAGE[V] DC200 - 400 (Prepare another power supply to the RC1 terminal *5) CURRENT[A] *1 0.67typ 1.0typ 1.0typ 1.0typ 1.0typ 1.0typ 1.0typ 1.0typ EFFICIENCY[%] *1 86.0typ 88.0typ 86.0typ 86.0typ 86.0typ 86.0typ 86.0typ 87.0typ VOLTAGE[V] 3.3 5 7.5 12 15 24 28 48 CURRENT[A] 50 50 33 21 16.5 10.5 9.0 5.2 LINE REGULATION[mV] 10max 10max 20max 24max 30max 48max 56max 96max LOAD REGULATION[mV] 150max 150max 150max 100max 100max 100max 100max 100max 0 to +95C *2 80max 80max 100max 120max 120max 120max 120max 200max -20 to 0C *2 120max 120max 130max 150max 150max 150max 150max 250max 0 to 15% Load*2 160max 160max 200max 240max 240max 240max 240max 400max 0 to +95C *2 160max 160max 200max 200max 200max 200max 200max 250max -20 to 0C *2 250max 250max 280max 280max 280max 280max 280max 400max 0 to 15% Load*2 300max 300max 300max 300max 300max 300max 300max 500max 0 to +50C 35max 50max 70max 120max 150max 240max 280max 480max -20 to +95C 66max 100max 140max 240max 300max 480max 560max 960max 20max 30max 40max 60max 90max 90max 180max RIPPLE[mVp-p] OUTPUT RIPPLE NOISE[mVp-p] TEMPERATURE REGULATION[mV] DRIFT[mV] *3 16max 200max (DCIN 280V, Io=100%) START-UP TIME[ms] 2.97 - 3.63 4.50 - 5.50 6.75 - 8.25 10.80 - 13.20 13.50 - 16.50 21.60 - 26.40 25.20 - 30.80 43.20 - 52.80 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 28.00 - 29.12 48.00 - 49.92 PROTECTION OVERVOLTAGE PROTECTION[V] 4.20 - 4.85 6.30 - 7.30 8.70 - 10.20 13.90 - 16.35 17.25 - 20.25 CIRCUIT AND REMOTE SENSING Provided OTHERS REMOTE ON/OFF (RC1) *6 Provided (Logic H : ON, L :OFF) Required external power source 27.60 - 32.40 32.20 - 37.80 55.20 - 64.80 OUTPUT VOLTAGE ADJUSTMENT RANGE[V] *4 OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically SNDHS INPUT-OUTPUT, RC2 ISOLATION ENVIRONMENT SAFETY OTHERS *1 *2 *3 *4 *5 *8 INPUT-FG AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) OUTPUT, RC2-FG *8 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (2015C) OUTPUT-RC2 *8 AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (2015C) OPERATING TEMP.,HUMID.AND ALTITUDE *7 -20 to +95C (Aluminum base plate of the power module), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +95C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis AGENCY APPROVALS UL60950-1, C-UL, EN60950-1 CASE SIZE/WEIGHT 74.2X44.5X127mm [2.92X1.75X5.0 inches](WXHXD) / 310g max COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) At rated input(DC280V) and rated load. Ripple and ripple noise is measured by using measuring board with capacitor of 22mF at 150mm [5.91 inches] from output terminal. Refer to the instruction manual 3.2. Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Refer to the instruction manual 4.6. Refer to the instruction manual 2, 4.4 SNDHS-12 *6 *7 *8 Refer to the instruction manual 4.4 Refer to the instruction manual 6.2 "RC2" is applicable to an option not to need external power source. SNDHS250B External view Connector for remote ON/OFF (optional) 4-f4.5 [4-f0.177] Mounting hole 4 4 2 1 2 1 CN1 2 +Vin -Vin RC1 CN2 1 CN5 0.5 [4.600.02] 116.84 7.4 [0.29] Voltage adjust PointB CN3 12 8.4 [0.33] 31.8 [1.25] 4 CN4 1 TB1 -Vout 8.6 M4 PointA Terminal cover [0.34] 22 10 [0.87] [0.39] 10 10 [0.39] [0.39] 5.08 64.04 [0.20] [2.520.02] 0.5 74.2 [2.92] 44.5 max Power module (DHS250B) [1.75 max] 5.08 +Vout [0.20] 127 [5.00] Name plate Base plate Tolerance : 1 [0.04] Weight : 310g max Dimensions in mm, [ ]=inches PCB material/thickness : FR-4 / 1.6mm [0.06] Base plate material/thickness : Alminum / 3.0mm[0.12] Screw tightening torque : 1.6N-m (16.9kgf-cm) max Component positions and sizes are for your reference if they have no dimensions. Please connect safety ground to the base plate in f4.5 [f0.177] hole. SNDHS SNDHS-13 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Cosel: SNDHS100B15 SNDHS250B48 SNDHS50B28 SNDHS250B12 SNDHS50B12 SNDHS50B05 SNDHS250B24 SNDHS250B05 SNDHS100B24 SNDHS50B03 SNDHS50B15 SNDHS100B03 SNDHS250B28 SNDHS100B28 SNDHS50B24 SNDHS250B07 SNDHS250B15 SNDHS250B03 SNDHS100B12 SNDHS100B05