N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Features * * * * * CAS Latency and Frequency CAS Latency 2 2.5 3 Maximum Operating Frequency (MHz) DDR400 DDR333 DDR266B (5T) (6K) (-75B) 133 100 166 166 133 200 - * * * * * * * * * * DDR 256M bit, die C, based on 110nm design rules * Double data rate architecture: two data transfers per clock cycle * Bidirectional data strobe (DQS) is transmitted and received with data, to be used in capturing data at the receiver * DQS is edge-aligned with data for reads and is centeraligned with data for writes Differential clock inputs (CK and CK) Four internal banks for concurrent operation Data mask (DM) for write data DLL aligns DQ and DQS transitions with CK transitions Commands entered on each positive CK edge; data and data mask referenced to both edges of DQS Burst lengths: 2, 4, or 8 CAS Latency: 2/2.5(DDR333) , 2.5/3(DDR400) Auto Precharge option for each burst access Auto Refresh and Self Refresh Modes 7.8s Maximum Average Periodic Refresh Interval 2.5V (SSTL_2 compatible) I/O VDD = VDDQ = 2.5V 0.2V (DDR333) VDD = VDDQ = 2.6V 0.1V (DDR400) Available in Halogen and Lead Free packaging Description N2DS25640CT, N2DS25680CT and N2DS25616CT, N2DS25640CS, N2DS25680CS and N2DS25616CS are die C of 256Mb SDRAM devices based using DDR interface. They are all based on Nanya's 110 nm design process. The DDR SDRAM provides for programmable Read or Write burst lengths of 2, 4, or 8 locations. An Auto Precharge function may be enabled to provide a self-timed row precharge that is initiated at the end of the burst access. The 256Mb DDR SDRAM uses a double-data-rate architecture to achieve high-speed operation. The double data rate architecture is essentially a 2n prefetch architecture with an interface designed to transfer two data words per clock cycle at the I/O pins. A single read or write access for the 256Mb DDR SDRAM effectively consists of a single 2n-bit wide, one clock cycle data transfer at the internal DRAM core and two corresponding n-bit wide, one-half-clock-cycle data transfers at the I/O pins. As with standard SDRAMs, the pipelined, multibank architecture of DDR SDRAMs allows for concurrent operation, thereby providing high effective bandwidth by hiding row precharge and activation time. A bidirectional data strobe (DQS) is transmitted externally, along with data, for use in data capture at the receiver. DQS is a strobe transmitted by the DDR SDRAM during Reads and by the memory controller during Writes. DQS is edgealigned with data for Reads and center-aligned with data for Writes. The functionality described and the timing specifications included in this data sheet are for the DLL Enabled mode of operation. An auto refresh mode is provided along with a power-saving Power Down mode. All inputs are compatible with the JEDEC Standard for SSTL_2. All outputs are SSTL_2, Class II compatible. The 256Mb DDR SDRAM operates from a differential clock (CK and CK; the crossing of CK going high and CK going LOW is referred to as the positive edge of CK). Commands (address and control signals) are registered at every positive edge of CK. Input data is registered on both edges of DQS, and output data is referenced to both edges of DQS, as well as to both edges of CK. Read and write accesses to the DDR SDRAM are burst oriented; accesses start at a selected location and continue for a programmed number of locations in a programmed sequence. Accesses begin with the registration of an Active command, which is then followed by a Read or Write command. The address bits registered coincident with the Active command are used to select the bank and row to be accessed. The address bits registered coincident with the Read or Write command are used to select the bank and the starting column location for the burst access. REV 1.1 Jun 29, 2005 1 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Ordering Information Speed Org. Part Number Package N2DS25640CT-5T 64M x 4 32M x 8 16M x 16 3-3-3 DDR400 166 2.5-3-3 DDR333 N2DS25640CT-75B 133 2.5-3-3 DDR266 N2DS25680CT-5T 200 3-3-3 DDR400 166 2.5-3-3 DDR333 N2DS25680CT-75B 133 2.5-3-3 DDR266 N2DS25616CT-5T 200 3-3-3 DDR400 166 2.5-3-3 DDR333 133 2.5-3-3 DDR266 200 3-3-3 DDR400 166 2.5-3-3 DDR333 133 2.5-3-3 DDR266 200 3-3-3 DDR400 166 2.5-3-3 DDR333 133 2.5-3-3 DDR266 200 3-3-3 DDR400 166 2.5-3-3 DDR333 133 2.5-3-3 DDR266 N2DS25640CT-6K N2DS25680CT-6K N2DS25616CT-6K TSOP2 TSOP2 TSOP2 N2DS25640CS-5T N2DS25640CS-6K TSOP2 Green Packing N2DS25640CS-75B N2DS25680CS-5T 32M x 8 N2DS25680CS-6K TSOP2 Green Packing N2DS25680CS-75B N2DS25616CS-5T 16M x 16 Comments 200 N2DS25616CT-75B 64M x 4 Clock (MHz) CL-tRCD-tRP N2DS25616CS-6K TSOP2 Green Packing N2DS25616CS-75B Note: 1. At the present time, there are no plans to support DDR SDRAMs with the QFC function. All reference to QFC are for information only Green Packing are Lead and Halogen free products REV 1.1 Jun 29, 2005 2 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Pin Configuration - 400mil TSOP II (x4 / x8 / x16) VDD VDD VDD 1 66 VSS VSS VSS NC DQ0 DQ0 2 65 DQ15 DQ7 NC VDDQ VDDQ VDDQ 3 64 VSSQ VSSQ VSSQ NC NC DQ1 4 63 DQ14 NC NC DQ0 DQ1 DQ13 DQ6 DQ3 VSSQ VSSQ VSSQ 6 61 VDDQ VDDQ VDDQ NC NC DQ3 7 60 DQ12 NC NC NC DQ2 DQ4 8 59 DQ11 DQ5 NC VDDQ VDDQ VDDQ 9 58 VSSQ VSSQ VSSQ NC NC DQ5 10 57 DQ10 NC NC DQ1 DQ3 DQ6 11 56 DQ9 DQ4 DQ2 VSSQ VSSQ VSSQ 12 55 VDDQ VDDQ VDDQ NC NC DQ7 13 54 DQ8 NC NC NC NC NC 14 53 NC NC NC VDDQ VDDQ 15 52 VSSQ VSSQ VSSQ NC NC VDDQ LDQS 16 51 UDQS DQS DQS NC NC NC 17 50 NC NC NC VDD VDD VDD 18 49 VREF VREF VREF NU NU NU 19 48 VSS VSS VSS NC NC LDM* 20 47 UDM* DM* DM* WE CAS WE CAS WE CAS 21 46 22 45 CK CK CK CK CK CK RAS RAS RAS 23 44 CKE CKE CKE CS CS CS 24 NC NC NC NC NC NC 25 43 42 A12 A12 A12 BA0 BA0 BA1 26 41 A11 A11 A11 BA1 BA0 BA1 27 40 A10/AP A10/AP A10/AP 28 39 A9 A8 A9 A8 A9 A8 A0 A0 A0 29 38 A7 A7 A7 A1 A1 A1 30 37 A6 A6 A6 A2 A2 A2 31 36 A5 A5 A5 A3 A3 A3 A4 A4 A4 VDD VDD VDD VSS VSS VSS DQ2 5 62 32 33 35 34 66-pin Plastic TSOP-II 400mil 16Mb x 16 32Mb x 8 64Mb x 4 Column Address Table Organization Column Address 64Mb x 4 A0-A9, A11 32Mb x 8 A0-A9 16Mb x 16 A0-A8 *DM is internally loaded to match DQ and DQS identically. REV 1.1 Jun 29, 2005 3 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Input/Output Functional Description Symbol Type Function Input Clock: CK and CK are differential clock inputs. All address and control input signals are sampled on the crossing of the positive edge of CK and negative edge of CK. Output (read) data is referenced to the crossings of CK and CK (both directions of crossing). Input Clock Enable: CKE HIGH activates, and CKE Low deactivates, internal clock signals and device input buffers and output drivers. Taking CKE Low provides Precharge Power Down and Self Refresh operation (all banks idle), or Active Power Down (row Active in any bank). CKE is synchronous for power down entry and exit, and for self refresh entry. CKE is asynchronous for self refresh exit. CKE must be maintained high throughout read and write accesses. Input buffers, excluding CK, CK and CKE are disabled during Power Down. Input buffers, excluding CKE, are disabled during self refresh. The standard pinout includes one CKE pin. Optional pinouts might include CKE1 on a different pin, in addition to CKE0, to facilitate independent power down control of stacked devices. CS, CS0, CS1 Input Chip Select: All commands are masked when CS is registered high. CS provides for external bank selection on systems with multiple banks. CS is considered part of the command code. The standard pinout includes one CS pin. Optional pinouts might include CS1 on a different pin, in addition to CS0, to allow upper or lower deck selection on stacked devices. RAS, CAS, WE Input Command Inputs: RAS, CAS and WE (along with CS) define the command being entered. DM Input Input Data Mask: DM is an input mask signal for write data. Input data is masked when DM is sampled high coincident with that input data during a Write access. DM is sampled on both edges of DQS. Although DM pins are input only, the DM loading matches the DQ and DQS loading. During a Read, DM can be driven high, low, or floated. BA0, BA1 Input Bank Address Inputs: BA0 and BA1 define to which bank an Active, Read, Write or Precharge command is being applied. BA0 and BA1 also determines if the mode register or extended mode register is to be accessed during a MRS or EMRS cycle. A0 - A12 Input Address Inputs: Provide the row address for Active commands, and the column address and Auto Precharge bit for Read/Write commands, to select one location out of the memory array in the respective bank. A10 is sampled during a Precharge command to determine whether the Precharge applies to one bank (A10 low) or all banks (A10 high). If only one bank is to be precharged, the bank is selected by BA0, BA1. The address inputs also provide the op-code during a Mode Register Set command. DQ Input/Output Data Input/Output: Data bus. DQS, LDQS, UDQS Input/Output Data Strobe: Output with read data, input with write data. Edge-aligned with read data, centered in write data. Used to capture write data. For the x16, LDQS corresponds to the data on DQ0DQ7; UDQS corresponds to the data on DQ8-DQ15 CK, CK CKE, CKE0, CKE1 NC No Connect: No internal electrical connection is present. NU Electrical connection is present. Should not be connected at second level of assembly. VDDQ Supply DQ Power Supply: 2.5V 0.2V. VSSQ Supply DQ Ground VDD Supply Power Supply: 2.5V 0.2V. VSS Supply Ground VREF Supply SSTL_2 reference voltage: (VDDQ / 2) 1%. REV 1.1 Jun 29, 2005 4 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Control Logic 2 Bank2 Bank3 CK, CK DLL 2 8192 4 8 8 1024 (x8) Write FIFO & Drivers 1 1 DQS Generator Input Register 1 Mask 1 1 1 4 4 4 clk clk out in Data 4 2 8 10 Column-Address Counter/Latch 4 COL0 I/O Gating DM Mask Logic Column Decoder 11 Drivers 8 Sense Amplifiers Data 4 MUX Bank0 Memory Array (8192 x 1024 x 8) Read Latch 8192 CK, CK COL0 DQS DQ0-DQ3, DM DQS 1 Receivers 15 Refresh Counter 13 A0-A12, BA0, BA1 13 Address Register 15 13 Bank Control Logic Mode Registers Bank0 Row-Address Latch & Decoder Bank1 Row-Address MUX CKE CK CK CS WE CAS RAS Command Decode Block Diagram (64Mb x 4) 4 COL0 1 Note: This Functional Block Diagram is intended to facilitate user understanding of the operation of the device; it does not represent an actual circuit implementation. Note: DM is a unidirectional signal (input only), but is internally loaded to match the load of the bidirectional DQ and DQS signals. REV 1.1 Jun 29, 2005 5 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Control Logic CK, CK DLL 16 Sense Amplifiers 2 Data 8 8 16 16 512 (x16) Write FIFO & Drivers 1 Input Register 1 Mask 1 1 1 8 8 8 clk clk out in Data 8 9 Column-Address Counter/Latch 1 DQS Generator 2 16 Column Decoder 10 8 COL0 I/O Gating DM Mask Logic CK, CK COL0 Drivers Bank0 Memory Array (8192 x 512 x 16) MUX 8192 DQS DQ0-DQ7, DM DQS 1 Receivers 2 Bank3 Read Latch Refresh Counter 13 15 Address Register A0-A12, BA0, BA1 Bank2 8192 13 15 13 Bank Control Logic Mode Registers Bank0 Row-Address Latch & Decoder Bank1 Row-Address MUX CKE CK CK CS WE CAS RAS Command Decode Block Diagram (32Mb x 8) 8 COL0 1 Note: This Functional Block Diagram is intended to facilitate user understanding of the operation of the device; it does not represent an actual circuit implementation. Note: DM is a unidirectional signal (input only), but is internally loaded to match the load of the bidirectional DQ and DQS signals. REV 1.1 Jun 29, 2005 6 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Control Logic CK, CK DLL 32 Sense Amplifiers 2 Data 16 16 32 32 256 (x32) Write FIFO & Drivers 1 Input Register 1 Mask 1 1 1 16 16 16 clk clk out in Data 16 8 Column-Address Counter/Latch 1 DQS Generator 2 32 Column Decoder 9 16 COL0 I/O Gating DM Mask Logic CK, CK COL0 Drivers Bank0 Memory Array (8192 x 256 x 32) MUX 8192 DQS DQ0-DQ15, LDM, UDM LDQS,UDQS 1 Receivers 2 Bank3 Read Latch Refresh Counter 13 15 Address Register A0-A12, BA0, BA1 Bank2 8192 13 15 13 Bank Control Logic Mode Registers Bank0 Row-Address Latch & Decoder Bank1 Row-Address MUX CKE CK CK CS WE CAS RAS Command Decode Block Diagram (16Mb x 16) 16 COL0 1 Note: This Functional Block Diagram is intended to facilitate user understanding of the operation of the device; it does not represent an actual circuit implementation. Note: DM is a unidirectional signal (input only), but is internally loaded to match the load of the bidirectional DQ and DQS signals. REV 1.1 Jun 29, 2005 7 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Functional Description The 256Mb DDR SDRAM is a high-speed CMOS, dynamic random-access memory containing 268, 435, 456 bits. The 256Mb DDR SDRAM is internally configured as a quad-bank DRAM. The 256Mb DDR SDRAM uses a double-data-rate architecture to achieve high-speed operation. The double-data-rate architecture is essentially a 2n prefetch architecture, with an interface designed to transfer two data words per clock cycle at the I/O pins. A single read or write access for the 256Mb DDR SDRAM consists of a single 2n-bit wide, one clock cycle data transfer at the internal DRAM core and two corresponding n-bit wide, one-half clock cycle data transfers at the I/O pins. Read and write accesses to the DDR SDRAM are burst oriented; accesses start at a selected location and continue for a programmed number of locations in a programmed sequence. Accesses begin with the registration of an Active command, which is then followed by a Read or Write command. The address bits registered coincident with the Active command are used to select the bank and row to be accessed (BA0, BA1 select the bank; A0-A12 select the row). The address bits registered coincident with the Read or Write command are used to select the starting column location for the burst access. Prior to normal operation, the DDR SDRAM must be initialized. The following sections provide detailed information covering device initialization, register definition, command descriptions and device operation. Initialization Only one of the following two conditions must be met. * No power sequencing is specified during power up or power down given the following criteria: VDD and VDDQ are driven from a single power converter output VTT meets the specification A minimum resistance of 42 ohms limits the input current from the VTT supply into any pin and VREF tracks VDDQ /2 or * The following relationships must be followed: VDDQ is driven after or with VDD such that VDDQ < VDD + 0.3V VTT is driven after or with VDDQ such that VTT < VDDQ + 0.3V VREF is driven after or with VDDQ such that VREF < VDDQ + 0.3V The DQ and DQS outputs are in the High-Z state, where they remain until driven in normal operation (by a read access). After all power supply and reference voltages are stable, and the clock is stable, the DDR SDRAM requires a 200s delay prior to applying an executable command. Once the 200s delay has been satisfied, a Deselect or NOP command should be applied, and CKE must be brought HIGH. Following the NOP command, a Precharge ALL command must be applied. Next a Mode Register Set command must be issued for the Extended Mode Register, to enable the DLL, then a Mode Register Set command must be issued for the Mode Register, to reset the DLL, and to program the operating parameters. 200 clock cycles are required between the DLL reset and any read command. A Precharge ALL command should be applied, placing the device in the "all banks idle" state Once in the idle state, two auto refresh cycles must be performed. Additionally, a Mode Register Set command for the Mode Register, with the reset DLL bit deactivated (i.e. to program operating parameters without resetting the DLL) must be performed. Following these cycles, the DDR SDRAM is ready for normal operation. DDR SDRAM's may be reinitialized at any time during normal operation by asserting a valid MRS command to either the base or extended mode registers without affecting the contents of the memory array. The contents of either the mode register or extended mode register can be modified at any valid time during device operation without affecting the state of the internal address refresh counters used for device refresh. REV 1.1 Jun 29, 2005 8 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Register Definition Mode Register The Mode Register is used to define the specific mode of operation of the DDR SDRAM. This definition includes the selection of a burst length, a burst type, a CAS latency, and an operating mode. The Mode Register is programmed via the Mode Register Set command (with BA0 = 0 and BA1 = 0) and retains the stored information until it is programmed again or the device loses power (except for bit A8, which is self-clearing). Mode Register bits A0-A2 specify the burst length, A3 specifies the type of burst (sequential or interleaved), A4-A6 specify the CAS latency, and A7-A12 specify the operating mode. The Mode Register must be loaded when all banks are idle, and the controller must wait the specified time before initiating the subsequent operation. Violating either of these requirements results in unspecified operation. Burst Length Read and write accesses to the DDR SDRAM are burst oriented, with the burst length being programmable. The burst length determines the maximum number of column locations that can be accessed for a given Read or Write command. Burst lengths of 2, 4, or 8 locations are available for both the sequential and the interleaved burst types. Reserved states should not be used, as unknown operation or incompatibility with future versions may result. When a Read or Write command is issued, a block of columns equal to the burst length is effectively selected. All accesses for that burst take place within this block, meaning that the burst wraps within the block if a boundary is reached. The block is uniquely selected by A1-Ai when the burst length is set to two, by A2-Ai when the burst length is set to four and by A3-Ai when the burst length is set to eight (where Ai is the most significant column address bit for a given configuration). The remaining (least significant) address bit(s) is (are) used to select the starting location within the block. The programmed burst length applies to both Read and Write bursts. REV 1.1 Jun 29, 2005 9 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Mode Register Operation BA1 BA0 0* 0* A12 - A9 A8 A12 A11 A10 A9 A8 A7 A5 A4 CAS Latency Operating Mode A7 A6 A6 - A0 Operating Mode 0 0 0 Valid Normal operation Do not reset DLL 0 1 0 Valid Normal operation in DLL Reset 0 0 1 VS** Vendor-Specific Test Mode - - - A3 A2 BT A1 Burst Length A3 Burst Type 0 Sequential 1 Interleave A0 Address Bus Mode Register Reserved CAS Latency Burst Length A6 A5 A4 Latency A2 A1 A0 Burst Length 0 0 0 Reserved 0 0 0 Reserved 0 0 1 Reserved 0 0 1 2 0 1 0 2 0 1 0 4 0 1 1 3 (Option) 0 1 1 8 1 0 0 Reserved 1 0 0 Reserved 1 0 1 1.5 (Option) 1 0 1 Reserved 1 1 0 2.5 1 1 0 Reserved 1 1 1 Reserved 1 1 1 Reserved VS** Vendor Specific * BA0 and BA1 must be 0, 0 to select the Mode Register (vs. the Extended Mode Register). REV 1.1 Jun 29, 2005 10 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Burst Definition Burst Length Starting Column Address A2 A1 A0 Type = Sequential Type = Interleaved 0 0-1 0-1 1 1-0 1-0 0 0 0-1-2-3 0-1-2-3 0 1 1-2-3-0 1-0-3-2 1 0 2-3-0-1 2-3-0-1 1 1 3-0-1-2 3-2-1-0 0 0 0 0-1-2-3-4-5-6-7 0-1-2-3-4-5-6-7 0 0 1 1-2-3-4-5-6-7-0 1-0-3-2-5-4-7-6 0 1 0 2-3-4-5-6-7-0-1 2-3-0-1-6-7-4-5 0 1 1 3-4-5-6-7-0-1-2 3-2-1-0-7-6-5-4 1 0 0 4-5-6-7-0-1-2-3 4-5-6-7-0-1-2-3 1 0 1 5-6-7-0-1-2-3-4 5-4-7-6-1-0-3-2 1 1 0 6-7-0-1-2-3-4-5 6-7-4-5-2-3-0-1 1 1 1 7-0-1-2-3-4-5-6 7-6-5-4-3-2-1-0 2 4 8 Order of Accesses Within a Burst Notes: 1. For a burst length of two, A1-A i selects the two-data-element block; A0 selects the first access within the block. 2. For a burst length of four, A2-A i selects the four-data-element block; A0-A1 selects the first access within the block. 3. For a burst length of eight, A3-A i selects the eight-data- element block; A0-A2 selects the first access within the block. 4. Whenever a boundary of the block is reached within a given sequence above, the following access wraps within the block. Burst Type Accesses within a given burst may be programmed to be either sequential or interleaved; this is referred to as the burst type and is selected via bit A3. The ordering of accesses within a burst is determined by the burst length, the burst type and the starting column address, as shown in Burst Definition on page 11. Read Latency The Read latency, or CAS latency, is the delay, in clock cycles, between the registration of a Read command and the availability of the first burst of output data. The latency can be programmed 2 or 2.5 clocks. If a Read command is registered at clock edge n, and the latency is m clocks, the data is available nominally coincident with clock edge n + m. Reserved states should not be used as unknown operation or incompatibility with future versions may result. REV 1.1 Jun 29, 2005 11 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Operating Mode The normal operating mode is selected by issuing a Mode Register Set Command with bits A7-A12 to zero, and bits A0-A6 set to the desired values. A DLL reset is initiated by issuing a Mode Register Set command with bits A7 and A9-A12 each set to zero, bit A8 set to one, and bits A0-A6 set to the desired values. A Mode Register Set command issued to reset the DLL should always be followed by a Mode Register Set command to select normal operating mode. All other combinations of values for A7-A12 are reserved for future use and/or test modes. Test modes and reserved states should not be used as unknown operation or incompatibility with future versions may result. CAS Latencies CAS Latency = 2, BL = 4 CK CK Command Read NOP NOP NOP NOP NOP CL=2 DQS DQ CAS Latency = 2.5, BL = 4 CK CK Command Read NOP NOP NOP NOP NOP CL=2.5 DQS DQ Don't Care Shown with nominal tAC, tDQSCK, and tDQSQ. REV 1.1 Jun 29, 2005 12 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Extended Mode Register The Extended Mode Register controls functions beyond those controlled by the Mode Register; these additional functions include DLL enable/disable, bit A0; output drive strength selection, bit A1; and QFC output enable/disable, bit A2 (NTC optional). These functions are controlled via the bit settings shown in the Extended Mode Register Definition. The Extended Mode Register is programmed via the Mode Register Set command (with BA0 = 1 and BA1 = 0) and retains the stored information until it is programmed again or the device loses power. The Extended Mode Register must be loaded when all banks are idle, and the controller must wait the specified time before initiating any subsequent operation. Violating either of these requirements result in unspecified operation. DLL Enable/Disable The DLL must be enabled for normal operation. DLL enable is required during power up initialization, and upon returning to normal operation after having disabled the DLL for the purpose of debug or evaluation. The DLL is automatically disabled when entering self refresh operation and is automatically re-enabled upon exit of self refresh operation. Any time the DLL is enabled, 200 clock cycles must occur to allow time for the internal clock to lock to the externally applied clock before a Read command can be issued. This is the reason for introducing timing parameter tXSRD for DDR SDRAM's (Exit Self Refresh to Read Command). Non- Read commands can be issued 2 clocks after the DLL is enabled via the EMRS command (tMRD) or 10 clocks after the DLL is enabled via self refresh exit command (tXSNR, Exit Self Refresh to Non-Read Command). Output Drive Strength The normal drive strength for all outputs is specified to be SSTL_2, Class II. QFC Enable/Disable The QFC signal is an optional DRAM output control used to isolate module loads (DIMMs) from the system memory bus by means of external FET switches when the given module (DIMM) is not being accessed. The QFC function is an optional feature for NANYA and is not included on all DDR SDRAM devices. REV 1.1 Jun 29, 2005 13 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Extended Mode Register Definition BA1 BA0 0* 1* A12 A11 A10 A8 A9 A7 A6 A5 A4 A3 Operating Mode A2 A1 A0 Address Bus QFC DS DLL Extended Mode Register Drive Strength A12 - A3 A2 - A0 Operating Mode 0 Valid Normal Operation - - All other states Reserved A2 QFC 0 Disable 1 Enable (Optional) * BA0 and BA1 must be 1, 0 to select the Extended Mode Register (vs. the base Mode Register) REV 1.1 Jun 29, 2005 A1 Drive Strength 0 Normal 1 Reserved A0 DLL 0 Enable 1 Disable 14 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Commands Truth Tables 1a and 1b provide a reference of the commands supported by DDR SDRAM devices. A verbal description of each commands follows. Truth Table 1a: Commands Name (Function) CS RAS CAS WE Address MNE Notes Deselect (Nop) H X X X X NOP 1, 9 No Operation (Nop) L H H H X NOP 1, 9 Active (Select Bank And Activate Row) L L H H Bank/Row ACT 1, 3 Read (Select Bank And Column, And Start Read Burst) L H L H Bank/Col Read 1, 4 Write (Select Bank And Column, And Start Write Burst) L H L L Bank/Col Write 1, 4 Burst Terminate L H H L X BST 1, 8 Precharge (Deactivate Row In Bank Or Banks) L L H L Code PRE 1, 5 Auto Refresh Or Self Refresh (Enter Self Refresh Mode) L L L H X AR / SR 1, 6, 7 Mode Register Set L L L L Op-Code MRS 1, 2 1. CKE is high for all commands shown except Self Refresh. 2. BA0, BA1 select either the Base or the Extended Mode Register (BA0 = 0, BA1 = 0 selects Mode Register; BA0 = 1, BA1 = 0 selects Extended Mode Register; other combinations of BA0-BA1 are reserved; A0-A12 provide the op-code to be written to the selected Mode Register.) 3. BA0-BA1 provide bank address and A0-A12 provide row address. 4. BA0, BA1 provide bank address; A0-Ai provide column address (where i = 9 for x8 and 9, 11 for x4); A10 high enables the Auto Precharge feature (non-persistent), A10 low disables the Auto Precharge feature. 5. A10 LOW: BA0, BA1 determine which bank is precharged. A10 HIGH: all banks are precharged and BA0, BA1 are "Don't Care." 6. This command is auto refresh if CKE is high; Self Refresh if CKE is low. 7. Internal refresh counter controls row and bank addressing; all inputs and I/Os are "Don't Care" except for CKE. 8. Applies only to read bursts with Auto Precharge disabled; this command is undefined (and should not be used) for read bursts with Auto Precharge enabled or for write bursts 9. Deselect and NOP are functionally interchangeable. Truth Table 1b: DM Operation Name (Function) DM DQs Notes Write Enable L Valid 1 Write Inhibit H X 1 1. Used to mask write data; provided coincident with the corresponding data. REV 1.1 Jun 29, 2005 15 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Deselect The Deselect function prevents new commands from being executed by the DDR SDRAM. The DDR SDRAM is effectively deselected. Operations already in progress are not affected. No Operation (NOP) The No Operation (NOP) command is used to perform a NOP to a DDR SDRAM. This prevents unwanted commands from being registered during idle or wait states. Operations already in progress are not affected. Mode Register Set The mode registers are loaded via inputs A0-A12, BA0 and BA1 while issuing the Mode Register Set Command. See mode register descriptions in the Register Definition section. The Mode Register Set command can only be issued when all banks are idle and no bursts are in progress. A subsequent executable command cannot be issued until tMRD is met. Active The Active command is used to open (or activate) a row in a particular bank for a subsequent access. The value on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0-A12 selects the row. This row remains active (or open) for accesses until a Precharge (or Read or Write with Auto Precharge) is issued to that bank. A Precharge (or Read or Write with Auto Precharge) command must be issued and completed before opening a different row in the same bank. Read The Read command is used to initiate a burst read access to an active (open) row. The value on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0-Ai, Aj (where [i = 9, j = don't care] for x8; where [i = 9, j = 11] for x4) selects the starting column location. The value on input A10 determines whether or not Auto Precharge is used. If Auto Precharge is selected, the row being accessed is precharged at the end of the Read burst; if Auto Precharge is not selected, the row remains open for subsequent accesses. Write The Write command is used to initiate a burst write access to an active (open) row. The value on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0-Ai, Aj (where [i = 9, j = don't care] for x8; where [i = 9, j = 11] for x4) selects the starting column location. The value on input A10 determines whether or not Auto Precharge is used. If Auto Precharge is selected, the row being accessed is precharged at the end of the Write burst; if Auto Precharge is not selected, the row remains open for subsequent accesses. Input data appearing on the DQs is written to the memory array subject to the DM input logic level appearing coincident with the data. If a given DM signal is registered low, the corresponding data is written to memory; if the DM signal is registered high, the corresponding data inputs are ignored, and a Write is not executed to that byte/column location. Precharge The Precharge command is used to deactivate (close) the open row in a particular bank or the open row(s) in all banks. The bank(s) will be available for a subsequent row access a specified time (tRP) after the Precharge command is issued. Input A10 determines whether one or all banks are to be precharged, and in the case where only one bank is to be precharged, inputs BA0, BA1 select the bank. Otherwise BA0, BA1 are treated as "Don't Care." Once a bank has been precharged, it is in the idle state and must be activated prior to any Read or Write commands being issued to that bank. A precharge command is treated as a NOP if there is no open row in that bank, or if the previously open row is already in the process of precharging. REV 1.1 Jun 29, 2005 16 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Auto Precharge Auto Precharge is a feature which performs the same individual-bank precharge function described above, but without requiring an explicit command. This is accomplished by using A10 to enable Auto Precharge in conjunction with a specific Read or Write command. A precharge of the bank/row that is addressed with the Read or Write command is automatically performed upon completion of the Read or Write burst. Auto Precharge is non-persistent in that it is either enabled or disabled for each individual Read or Write command. Auto Precharge ensures that the precharge is initiated at the earliest valid stage within a burst. This is determined as if an explicit Precharge command was issued at the earliest possible time without violating tRAS(min). The user must not issue another command to the same bank until the precharge (tRP) is completed. The NTC DDR SDRAM devices supports the optional tRAS lockout feature. This feature allows a Read command with Auto Precharge to be issued to a bank that has been activated (opened) but has not yet satisfied the tRAS(min) specification. The tRAS lockout feature essentially delays the onset of the auto precharge operation until two conditions occur. One, the entire burst length of data has been successfully prefetched from the memory array; and two, tRAS(min) has been satisfied. As a means to specify whether a DDR SDRAM device supports the tRAS lockout feature, a new parameter has been defined, tRAP (RAS Command to Read Command with Auto Precharge or better stated Bank Activate to Read Command with Auto Precharge). For devices that support the tRAS lockout feature, tRAP = tRCD(min). This allows any Read Command (with or without Auto Precharge) to be issued to an open bank once tRCD(min) is satisfied. tRAP Definition CL=2, tCK=10ns CK CK Command NOP ACT NOP RD A NOP NOP DQ (BL=2) DQ0 tRASmin Command NOP ACT NOP RD A NOP NOP DQ (BL=4) Command DQ0 NOP ACT NOP RD A NOP NOP DQ (BL=8) DQ0 NOP NOP NOP NOP ACT NOP NOP NOP ACT NOP DQ1 * tRPmin NOP DQ1 NOP DQ2 * NOP DQ1 DQ3 tRPmin NOP DQ2 tRCDmin tRAPmin ACT * DQ3 * DQ4 DQ5 DQ6 DQ7 tRPmin Indicates Auto Precharge begins here The above timing diagrams show the effects of tRAP for devices that support tRAS lockout. In these cases, the Read with Auto Precharge command (RDA) is issued with tRCD(min) and dataout is available with the shortest latency from the Bank Activate command (ACT). The internal precharge operation, however, does not begin until after tRAS(min) is satisfied. Burst Terminate The Burst Terminate command is used to truncate read bursts (with Auto Precharge disabled). The most re-cently registered Read command prior to the Burst Terminate command is truncated, as shown in the Operation section of this data sheet. Write burst cycles are not to be terminated with the Burst Terminate command. REV 1.1 Jun 29, 2005 17 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Auto Refresh Auto Refresh is used during normal operation of the DDR SDRAM and is analogous to CAS Before RAS (CBR) Refresh in previous DRAM types. This command is nonpersistent, so it must be issued each time a refresh is required. The refresh addressing is generated by the internal refresh controller. This makes the address bits "Don't Care" during an Auto Refresh command. The 256Mb DDR SDRAM requires Auto Refresh cycles at an average periodic interval of 7.8s (maximum). Self Refresh The Self Refresh command can be used to retain data in the DDR SDRAM, even if the rest of the system is powered down. When in the self refresh mode, the DDR SDRAM retains data without external clocking. The Self Refresh command is initiated as an Auto Refresh command coincident with CKE transitioning low. The DLL is automatically disabled upon entering Self Refresh, and is automatically enabled upon exiting Self Refresh (200 clock cycles must then occur before a Read command can be issued). Input signals except CKE (low) are "Don't Care" during Self Refresh operation. The procedure for exiting self refresh requires a sequence of commands. CK (and CK) must be stable prior to CKE returning high. Once CKE is high, the SDRAM must have NOP commands issued for tXSNR because time is required for the completion of any internal refresh in progress. A simple algorithm for meeting both refresh and DLL requirements is to apply NOPs for 200 clock cycles before applying any other command. REV 1.1 Jun 29, 2005 18 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Operations Bank/Row Activation Before any Read or Write commands can be issued to a bank within the DDR SDRAM, a row in that bank must be "opened" (activated). This is accomplished via the Active command and addresses A0-A12, BA0 and BA1 (see Activating a Specific Row in a Specific Bank), which decode and select both the bank and the row to be activated. After opening a row (issuing an Active command), a Read or Write command may be issued to that row, subject to the tRCD specification. A subsequent Active command to a different row in the same bank can only be issued after the previous active row has been "closed" (precharged). The minimum time interval between successive Active commands to the same bank is defined by tRC. A subsequent Active command to another bank can be issued while the first bank is being accessed, which results in a reduction of total row-access overhead. The minimum time interval between successive Active commands to different banks is defined by tRRD. Activating a Specific Row in a Specific Bank CK CK CKE HIGH CS RAS CAS WE REV 1.1 Jun 29, 2005 A0-A12 RA BA0, BA1 BA RA = row address. BA = bank address. Don't Care 19 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM tRCD and tRRD Definition CK CK NOP ACT NOP ACT A0-A12 ROW ROW COL BA0, BA1 BA x BA y BA y tRRD NOP RD/WR Command NOP NOP tRCD Don't Care Reads Subsequent to programming the mode register with CAS latency, burst type, and burst length, Read bursts are initiated with a Read command. The starting column and bank addresses are provided with the Read command and Auto Precharge is either enabled or disabled for that burst access. If Auto Precharge is enabled, the row that is accessed starts precharge at the completion of the burst, provided tRAS has been satisfied. For the generic Read commands used in the following illustrations, Auto Precharge is disabled. During Read bursts, the valid data-out element from the starting column address is available following the CAS latency after the Read command. Each subsequent data-out element is valid nominally at the next positive or negative clock edge (i.e. at the next crossing of CK and CK). The following timing figure entitled "Read Burst: CAS Latencies (Burst Length=4)" illustrates the general timing for each supported CAS latency setting. DQS is driven by the DDR SDRAM along with output data. The initial low state on DQS is known as the read preamble; the low state coincident with the last data-out element is known as the read postamble. Upon completion of a burst, assuming no other commands have been initiated, the DQs and DQS goes High-Z. Data from any Read burst may be concatenated with or truncated with data from a subsequent Read command. In either case, a continuous flow of data can be maintained. The first data element from the new burst follows either the last element of a completed burst or the last desired data element of a longer burst which is being truncated. The new Read command should be issued x cycles after the first Read command, where x equals the number of desired data element pairs (pairs are required by the 2n prefetch architecture). This is shown in timing figure entitled "Consecutive Read Bursts: CAS Latencies (Burst Length =4 or 8)". A Read command can be initiated on any positive clock cycle following a previous Read command. Nonconsecutive Read data is shown in timing figure entitled "Non-Consecutive Read Bursts: CAS Latencies (Burst Length = 4)". Full-speed Random Read Accesses: CAS Latencies (Burst Length = 2, 4 or 8) within a page (or pages) can be performed as shown on page 25. REV 1.1 Jun 29, 2005 20 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Read Command CK CK CKE HIGH CS RAS CAS WE x4: A0-A9, A11 x8: A0-A9 CA EN AP A10 DIS AP BA0, BA1 BA CA = column address BA = bank address EN AP = enable Auto Precharge DIS AP = disable Auto Precharge Don't Care REV 1.1 Jun 29, 2005 21 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Read Burst: CAS Latencies (Burst Length = 4) CAS Latency = 2 CK CK Command Address Read NOP NOP NOP NOP NOP BA a,COL n CL=2 DQS DQ DOa-n tQCS QFC (Optional) tQCH CAS Latency = 2.5 CK CK Command Address Read NOP NOP NOP NOP NOP BA a,COL n CL=2.5 DQS DQ QFC DOa-n tQCS (Optional) tQCH Don't Care DO a-n = data out from bank a, column n. 3 subsequent elements of data out appear in the programmed order following DO a-n. Shown with nominal tAC, tDQSCK, and tDQSQ. QFC is an open drain driver. The output high level is achieved through an external pull up resistor connected to VDDQ. REV 1.1 Jun 29, 2005 22 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Consecutive Read Bursts: CAS Latencies (Burst Length = 4 or 8) CAS Latency = 2 CK CK Command Address Read NOP Read BAa, COL n NOP NOP NOP BAa, COL b CL=2 DQS DQ DOa-b DOa-n CAS Latency = 2.5 CK CK Command Address Read NOP Read BAa, COL n NOP NOP NOP BAa,COL b CL=2.5 DQS DQ DOa- n DOa- b DO a-n (or a-b) = data out from bank a, column n (or bank a, column b). When burst length = 4, the bursts are concatenated. When burst length = 8, the second burst interrupts the first. 3 subsequent elements of data out appear in the programmed order following DO a-n. 3 (or 7) subsequent elements of data out appear in the programmed order following DO a-b. Shown with nominal tAC, tDQSCK, and tDQSQ. REV 1.1 Jun 29, 2005 Don't Care 23 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Non-Consecutive Read Bursts: CAS Latencies (Burst Length = 4) CAS Latency = 2 CK CK Read Command Address NOP NOP Read BAa, COL n NOP NOP BAa, COL b CL=2 DQS DO a-n DQ DOa- b CAS Latency = 2.5 CK CK Command Address Read NOP NOP Read BAa, COL n NOP NOP NOP BAa, COL b CL=2.5 DQS DQ DO a-n DOa- b DO a-n (or a-b) = data out from bank a, column n (or bank a, column b). 3 subsequent elements of data out appear in the programmed order following DO a-n (and following DO a-b). Shown with nominal tAC, tDQSCK, and tDQSQ. REV 1.1 Jun 29, 2005 Don't Care 24 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Random Read Accesses: CAS Latencies (Burst Length = 2, 4 or 8) CAS Latency = 2 CK CK Command Address Read Read Read Read NOP BAa, COL n BAa, COL x BAa, COL b BAa, COL g NOP CL=2 DQS DQ DOa-n DOa-n' DOa-x DOa-x' DOa-b DOa-b' DOa-g CAS Latency = 2.5 CK CK Command Address Read Read Read Read BAa, COL n BAa, COL x BAa, COL b BAa, COL g NOP NOP CL=2.5 DQS DQ DOa-n DO a-n, etc. = data out from bank a, column n etc. n' etc. = odd or even complement of n, etc. (i.e., column address LSB inverted). Reads are to active rows in any banks. Shown with nominal tAC, tDQSCK, and tDQSQ. REV 1.1 Jun 29, 2005 DOa-n' DOa-x DOa-x' DOa-b DOa-b' Don't Care 25 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Data from any Read burst may be truncated with a Burst Terminate command, as shown in timing figure entitled Terminating a Read Burst: CAS Latencies (Burst Length = 8) on page 27. The Burst Terminate latency is equal to the read (CAS) latency, i.e. the Burst Terminate command should be issued x cycles after the Read command, where x equals the number of desired data element pairs. Data from any Read burst must be completed or truncated before a subsequent Write command can be issued. If truncation is necessary, the Burst Terminate command must be used, as shown in timing figure entitled Read to Write: CAS Latencies (Burst Length = 4 or 8) on page 28. The example is shown for tDQSS(min). The tDQSS(max) case, not shown here, has a longer bus idle time. tDQSS(min) and tDQSS(max) are defined in the section on Writes. A Read burst may be followed by, or truncated with, a Precharge command to the same bank (provided that Auto Precharge was not activated). The Precharge command should be issued x cycles after the Read command, where x equals the number of desired data element pairs (pairs are required by the 2n prefetch architecture). This is shown in timing figure Read to Precharge: CAS Latencies (Burst Length = 4 or 8) on page 29 for Read latencies of 2 and 2.5. Following the Precharge command, a subsequent command to the same bank cannot be issued until tRP is met. Note that part of the row precharge time is hidden during the access of the last data elements. In the case of a Read being executed to completion, a Precharge command issued at the optimum time (as described above) provides the same operation that would result from the same Read burst with Auto Precharge enabled. The disadvantage of the Precharge command is that it requires that the command and address busses be available at the appropriate time to issue the command. The advantage of the Precharge command is that it can be used to truncate bursts. REV 1.1 Jun 29, 2005 26 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Terminating a Read Burst: CAS Latencies (Burst Length = 8) CAS Latency = 2 CK CK Command Address Read NOP BST NOP NOP NOP BAa, COL n CL=2 DQS DQ DOa-n No further output data after this point. DQS tristated. CAS Latency = 2.5 CK CK Command Address Read NOP BST NOP NOP NOP BAa, COL n CL=2.5 DQS DQ DOa-n No further output data after this point. DQS tristated. DO a-n = data out from bank a, column n. Cases shown are bursts of 8 terminated after 4 data elements. 3 subsequent elements of data out appear in the programmed order following DO a-n. Shown with nominal tAC, tDQSCK, and tDQSQ. REV 1.1 Jun 29, 2005 Don't Care 27 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Read to Write: CAS Latencies (Burst Length = 4 or 8) CAS Latency = 2 CK CK Command Address Read BST NOP BAa, COL n Write NOP NOP BAa, COL b CL=2 tDQSS (min) DQS DQ DI a-b DOa-n DM CAS Latency = 2.5 CK CK Command Address Read BST NOP NOP BAa, COL n Write NOP BAa, COL b CL=2.5 tDQSS (min) DQS DQ Dla-b DOa-n DM DO a-n = data out from bank a, column n .DI a-b = data in to bank a, column b 1 subsequent elements of data out appear in the programmed order following DO a-n. Data In elements are applied following Dl a-b in the programmed order, according to burst length. Shown with nominal tAC, tDQSCK, and tDQSQ. REV 1.1 Jun 29, 2005 Don't Care 28 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Read to Precharge: CAS Latencies (Burst Length = 4 or 8) CAS Latency = 2 CK CK Command Read NOP PRE NOP NOP ACT tRP Address BA a or all BA a, COL n BA a, ROW CL=2 DQS DQ DOa-n CAS Latency = 2.5 CK CK Command Read NOP PRE NOP NOP ACT tRP Address BA a or all BA a, COL n BA a, ROW CL=2.5 DQS DQ DOa-n DO a-n = data out from bank a, column n. Cases shown are either uninterrupted bursts of 4 or interrupted bursts of 8. 3 subsequent elements of data out appear in the programmed order following DO a-n. Shown with nominal tAC, tDQSCK, and tDQSQ. REV 1.1 Jun 29, 2005 Don't Care 29 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Read with Auto Precharge: CAS Latencies (Burst Length = 4) CAS Latency = 2 CK CK Command Read with Auto Precharge NOP NOP NOP NOP tRP Address CL=2 DQS DQ DOa-n CAS Latency = 2.5 CK CK Command Read NOP PRE NOP NOP ACT tRP Address BA a or all BA a, COL n BA a, ROW CL=2.5 DQS DQ DOa-n DO a-n = data out from bank a, column n. Cases shown are either uninterrupted bursts of 4 or interrupted bursts of 8. 3 subsequent elements of data out appear in the programmed order following DO a-n. Shown with nominal tAC, tDQSCK, and tDQSQ. REV 1.1 Jun 29, 2005 Don't Care 30 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Writes Write bursts are initiated with a Write command, as shown in timing figure Write Command on page 32. The starting column and bank addresses are provided with the Write command, and Auto Precharge is either enabled or disabled for that access. If Auto Precharge is enabled, the row being accessed is precharged at the completion of the burst. For the generic Write commands used in the following illustrations, Auto Precharge is disabled. During Write bursts, the first valid data-in element is registered on the first rising edge of DQS following the write command, and subsequent data elements are registered on successive edges of DQS. The Low state on DQS between the Write command and the first rising edge is known as the write preamble; the Low state on DQS following the last data-in element is known as the write postamble. The time between the Write command and the first corresponding rising edge of DQS (tDQSS) is specified with a relatively wide range (from 75% to 125% of one clock cycle), so most of the Write diagrams that follow are drawn for the two extreme cases (i.e. tDQSS(min) and tDQSS(max)). Timing figure Write Burst (Burst Length = 4) on page 33 shows the two extremes of tDQSS for a burst of four. Upon completion of a burst, assuming no other commands have been initiated, the DQs and DQS enters High-Z and any additional input data is ignored. Data for any Write burst may be concatenated with or truncated with a subsequent Write command. In either case, a continuous flow of input data can be maintained. The new Write command can be issued on any positive edge of clock following the previous Write command. The first data element from the new burst is applied after either the last element of a completed burst or the last desired data element of a longer burst which is being truncated. The new Write command should be issued x cycles after the first Write command, where x equals the number of desired data element pairs (pairs are required by the 2n prefetch architecture). Timing figure Write to Write (Burst Length = 4) on page 34 shows concatenated bursts of 4. An example of nonconsecutive Writes is shown in timing figure Write to Write: Max DQSS, Non-Consecutive (Burst Length = 4) on page 35. Fullspeed random write accesses within a page or pages can be performed as shown in timing figure Random Write Cycles (Burst Length = 2, 4 or 8) on page 36. Data for any Write burst may be followed by a subsequent Read command. To follow a Write without truncating the write burst, tWTR (Write to Read) should be met as shown in timing figure Write to Read: Non-Interrupting (CAS Latency = 2; Burst Length = 4) on page 37. Data for any Write burst may be truncated by a subsequent (interrupting) Read command. This is illustrated in timing figures "Write to Read: Interrupting (CAS Latency =2; Burst Length = 8)", "Write to Read: Minimum DQSS, Odd Number of Data (3 bit Write), Interrupting (CAS Latency = 2; Burst Length = 8)", and "Write to Read: Nominal DQSS, Interrupting (CAS Latency = 2; Burst Length = 8)". Note that only the data-in pairs that are registered prior to the tWTR period are written to the internal array, and any subsequent data-in must be masked with DM, as shown in the diagrams noted previously. Data for any Write burst may be followed by a subsequent Precharge command. To follow a Write without truncating the write burst, tWR should be met as shown in timing figure Write to Precharge: Non-Interrupting (Burst Length = 4) on page 41. Data for any Write burst may be truncated by a subsequent Precharge command, as shown in timing figures Write to Precharge: Interrupting (Burst Length = 4 or 8) on page 42 to Write to Precharge: Nominal DQSS (2 bit Write), Interrupting (Burst Length = 4 or 8) on page 44. Note that only the data-in pairs that are registered prior to the tWR period are written to the internal array, and any subsequent data in should be masked with DM. Following the Precharge command, a subsequent command to the same bank cannot be issued until tRP is met. In the case of a Write burst being executed to completion, a Precharge command issued at the optimum time (as described above) provides the same operation that would result from the same burst with Auto Precharge. The disadvantage of the Precharge command is that it requires that the command and address busses be available at the appropriate time to issue the command. The advantage of the Precharge command is that it can be used to truncate bursts. REV 1.1 Jun 29, 2005 31 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Write Command CK CK CKE HIGH CS RAS CAS WE x4: A0-A9, A11 x8: A0-A9 CA EN AP A10 DIS AP BA0, BA1 BA CA = column address BA = bank address EN AP = enable Auto Precharge DIS AP = disable Auto Precharge Don't Care REV 1.1 Jun 29, 2005 32 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Write Burst (Burst Length = 4) Maximum DQSS T1 T2 T3 T4 CK CK Command Address Write NOP NOP NOP BA a, COL b tDQSS (max) DQS DQ Dla-b DM tQCSW(max) QFC (Optional) tQCHW(min) Minimum DQSS T1 T2 T3 T4 CK CK Command Address Write NOP NOP NOP BA a, COL b tDQSS (min) DQS DQ Dla-b DM QFC tQCSW(max) tQCHW(max) DI a-b = data in for bank a, column b. 3 subsequent elements of data in are applied in the programmed order following DI a-b. A non-interrupted burst is shown. A10 is Low with the Write command (Auto Precharge is disabled). QFC is an open drain driver. Its output high level is achieved through an externally connected pull up resistor connected to VDDQ. Don't Care REV 1.1 Jun 29, 2005 33 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Write to Write (Burst Length = 4) Maximum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Address Write NOP Write BAa, COL b NOP NOP NOP BAa, COL n tDQSS (max) DQS DQ DI a-b DI a-n DM Minimum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Address Write NOP BA, COL b Write NOP NOP NOP BA, COL n tDQSS (min) DQS DQ DI a-b DI a-n DM DI a-b = data in for bank a, column b, etc. 3 subsequent elements of data in are applied in the programmed order following DI a-b. 3 subsequent elements of data in are applied in the programmed order following DI a-n. A non-interrupted burst is shown. Each Write command may be to any bank. REV 1.1 Jun 29, 2005 Don't Care 34 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Write to Write: Max DQSS, Non-Consecutive (Burst Length = 4) T1 T2 T3 T4 T5 CK CK Command Address Write NOP NOP BAa, COL b Write NOP BAa, COL n tDQSS (max) DQS DQ DI a-b DI a-n DM DI a-b, etc. = data in for bank a, column b, etc. 3 subsequent elements of data in are applied in the programmed order following DI a-b. 3 subsequent elements of data in are applied in the programmed order following DI a-n. A non-interrupted burst is shown. Each Write command may be to any bank. REV 1.1 Jun 29, 2005 Don't Care 35 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Random Write Cycles (Burst Length = 2, 4 or 8) Maximum DQSS T1 T2 T3 T4 T5 CK CK Command Address Write Write BAa, COL b Write BAa, COL x Write BAa, COL n Write BAa, COL a BAa, COL g tDQSS (max) DQS DQ DI a-b DI a-b' DI a-x DI a-x' DI a-n DI a-n' DI a-a DI a-a' DM Minimum DQSS T1 T2 T3 T4 T5 CK CK Command Address Write Write BAa, COL b Write BAa, COL x Write BAa, COL n Write BAa, COL a BAa, COL g tDQSS (min) DQS DQ DI a-b DI a-b' DI a-x DI a-x' DI a-n DI a-n' DI a-a DI a-a' DI a-g DM DI a-b, etc. = data in for bank a, column b, etc. b', etc. = odd or even complement of b, etc. (i.e., column address LSB inverted). Each Write command may be to any bank. REV 1.1 Jun 29, 2005 Don't Care 36 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Write to Read: Non-Interrupting (CAS Latency = 2; Burst Length = 4) Maximum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tWTR Address BAa, COL b BAa, COL n CL = 2 tDQSS (max) DQS DQ DI a-b DM Minimum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tWTR Address BAa, COL n BAa, COL b CL = 2 tDQSS (min) DQS DQ DI a-b DM DI a-b = data in for bank a, column b. 3 subsequent elements of data in are applied in the programmed order following DI a-b. A non-interrupted burst is shown. tWTR is referenced from the first positive CK edge after the last data in pair. A10 is Low with the Write command (Auto Precharge is disabled). The Read and Write commands may be to any bank. REV 1.1 Jun 29, 2005 Don't Care 37 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Write to Read: Interrupting (CAS Latency = 2; Burst Length = 8) Maximum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tWTR Address BAa, COL n BAa, COL b CL = 2 tDQSS (max) DQS DQ DIa- b 1 DM 1 Minimum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tWTR Address BAa, COL n BAa, COL b CL = 2 tDQSS (min) DQS DQ DI a-b 1 DM 1 DI a-b = data in for bank a, column b. An interrupted burst is shown, 4 data elements are written. 3 subsequent elements of data in are applied in the programmed order following DI a-b. tWTR is referenced from the first positive CK edge after the last data in pair. The Read command masks the last 2 data elements in the burst. A10 is Low with the Write command (Auto Precharge is disabled). The Read and Write commands are not necessarily to the same bank. 1 = These bits are incorrectly written into the memory array if DM is low. REV 1.1 Jun 29, 2005 Don't Care 38 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Write to Read: Minimum DQSS, Odd Number of Data (3 bit Write), Interrupting (CAS Latency = 2; Burst Length = 8) T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tWTR Address BAa, COL n BAa, COL b CL = 2 tDQSS (min) DQS DQ DI a-b DM 1 2 2 DI a-b = data in for bank a, column b. An interrupted burst is shown, 3 data elements are written. 2 subsequent elements of data in are applied in the programmed order following DI a-b. tWTR is referenced from the first positive CK edge after the last desired data in pair (not the last desired data in element) The Read command masks the last 2 data elements in the burst. A10 is Low with the Write command (Auto Precharge is disabled). The Read and Write commands are not necessarily to the same bank. 1 = This bit is correctly written into the memory array if DM is low. Don't Care 2 = These bits are incorrectly written into the memory array if DM is low. REV 1.1 Jun 29, 2005 39 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Write to Read: Nominal DQSS, Interrupting (CAS Latency = 2; Burst Length = 8) T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tWTR Address BAa, COL n BAa, COL b CL = 2 tDQSS (nom) DQS DQ DI a-b DM 1 1 DI a-b = data in for bank a, column b. An interrupted burst is shown, 4 data elements are written. 3 subsequent elements of data in are applied in the programmed order following DI a-b. tWTR is referenced from the first positive CK edge after the last desired data in pair. The Read command masks the last 2 data elements in the burst. A10 is Low with the Write command (Auto Precharge is disabled). The Read and Write commands are not necessarily to the same bank. 1 = These bits are incorrectly written into the memory array if DM is low. REV 1.1 Jun 29, 2005 Don't Care 40 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Write to Precharge: Non-Interrupting (Burst Length = 4) Maximum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP NOP PRE tWR Address BA (a or all) BA a, COL b tRP tDQSS (max) DQS DQ DI a-b DM Minimum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP NOP PRE tWR Address BA (a or all) BA a, COL b tRP tDQSS (min) DQS DQ DI a-b DM DI a-b = data in for bank a, column b. 3 subsequent elements of data in are applied in the programmed order following DI a-b. A non-interrupted burst is shown. tWR is referenced from the first positive CK edge after the last data in pair. A10 is Low with the Write command (Auto Precharge is disabled). REV 1.1 Jun 29, 2005 Don't Care 41 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Write to Precharge: Interrupting (Burst Length = 4 or 8) Maximum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP PRE NOP tWR Address BA (a or all) BA a, COL b tDQSS (max) tRP 2 DQS DQ DI a-b 3 DM 1 3 1 Minimum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP PRE NOP tWR Address BA a, COL b BA (a or all) tDQSS (min) tRP 2 DQS DQ DM DI a-b 3 3 1 1 DI a-b = data in for bank a, column b. An interrupted burst is shown, 2 data elements are written. 1 subsequent element of data in is applied in the programmed order following DI a-b. tWR is referenced from the first positive CK edge after the last desired data in pair. The Precharge command masks the last 2 data elements in the burst, for burst length = 8. A10 is Low with the Write command (Auto Precharge is disabled). 1 = Can be don't care for programmed burst length of 4. 2 = For programmed burst length of 4, DQS becomes don't care at this point. 3 = These bits are incorrectly written into the memory array if DM is low. REV 1.1 Jun 29, 2005 Don't Care 42 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Write to Precharge: Minimum DQSS, Odd Number of Data (1 bit Write), Interrupting (Burst Length = 4 or 8) T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP PRE NOP tWR Address BA (a or all) BA a, COL b tDQSS (min) tRP 2 DQS DQ DM DI a-b 3 4 4 1 1 DI a-b = data in for bank a, column b. An interrupted burst is shown, 1 data element is written. tWR is referenced from the first positive CK edge after the last desired data in pair. The Precharge command masks the last 2 data elements in the burst. A10 is Low with the Write command (Auto Precharge is disabled). 1 = Can be don't care for programmed burst length of 4. 2 = For programmed burst length of 4, DQS becomes don't care at this point. 3 = This bit is correctly written into the memory array if DM is low. 4 = These bits are incorrectly written into the memory array if DM is low. REV 1.1 Jun 29, 2005 Don't Care 43 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Write to Precharge: Nominal DQSS (2 bit Write), Interrupting (Burst Length = 4 or 8) T1 T2 T3 T4 T5 T6 CK CK Write Command NOP NOP NOP PRE NOP tWR Address BA (a or all) BA a, COL b tDQSS (nom) tRP 2 DQS DQ DM DI a-b 3 3 1 1 DI a-b = Data In for bank a, column b. An interrupted burst is shown, 2 data elements are written. 1 subsequent element of data in is applied in the programmed order following DI a-b. tWR is referenced from the first positive CK edge after the last desired data in pair. The Precharge command masks the last 2 data elements in the burst. A10 is Low with the Write command (Auto Precharge is disabled). 1 = Can be don't care for programmed burst length of 4. 2 = For programmed burst length of 4, DQS becomes don't care at this point. 3 = These bits are incorrectly written into the memory array if DM is low. REV 1.1 Jun 29, 2005 Don't Care 44 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Precharge Command CK CK CKE HIGH CS RAS CAS WE A0-A9, A11, A12 All Banks A10 BA0, BA1 One Bank BA BA = bank address (if A10 is Low, otherwise Don't Care). Don't Care Precharge The Precharge command is used to deactivate the open row in a particular bank or the open row in all banks. The bank(s) is available for a subsequent row access some specified time (tRP) after the Precharge command is issued. Input A10 determines whether one or all banks are to be precharged, and in the case where only one bank is to be precharged, inputs BA0, BA1 select the bank. When all banks are to be precharged, inputs BA0, BA1 are treated as "Don't Care." Once a bank has been precharged, it is in the idle state and must be activated prior to any Read or Write commands being issued to that bank. REV 1.1 Jun 29, 2005 45 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Power Down Power Down is entered when CKE is registered low (no accesses can be in progress). If Power Down occurs when all banks are idle, this mode is referred to as Precharge Power Down; if Power Down occurs when there is a row active in any bank, this mode is referred to as Active Power Down. Entering Power Down deactivates the input and output buffers, excluding CK, CK and CKE. The DLL is still running in Power Down mode, so for maximum power savings, the user has the option of disabling the DLL prior to entering Power Down. In that case, the DLL must be enabled after exiting Power Down, and 200 clock cycles must occur before a Read command can be issued. In Power Down mode, CKE Low and a stable clock signal must be maintained at the inputs of the DDR SDRAM, and all other input signals are "Don't Care". However, Power Down duration is limited by the refresh requirements of the device, so in most applications, the self refresh mode is preferred over the DLL-disabled Power Down mode. The Power Down state is synchronously exited when CKE is registered high (along with a Nop or Deselect command). A valid, executable command may be applied one clock cycle later. Power Down CK CK tIS CKE Command VALID tIS NOP No column access in progress Exit power down mode Enter Power Down mode (Burst Read or Write operation must not be in progress) REV 1.1 Jun 29, 2005 VALID NOP tPDEX Don't Care 46 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Truth Table 2: Clock Enable (CKE) 1. 2. 3. 4. CKE n is the logic state of CKE at clock edge n: CKE n-1 was the state of CKE at the previous clock edge. Current state is the state of the DDR SDRAM immediately prior to clock edge n. Command n is the command registered at clock edge n, and action n is a result of command n. All states and sequences not shown are illegal or reserved. CKE n-1 CKEn Current State Previous Cycle Current Cycle Command n Self Refresh L L X Self Refresh L H Deselect or NOP Power Down L L X Power Down L H Deselect or NOP Exit Power Down All Banks Idle H L Deselect or NOP Precharge Power Down Entry All Banks Idle H L Auto Refresh Bank(s) Active H L Deselect or NOP H H See "Truth Table 3: Current State Bank n - Command to Bank n (Same Bank)" on page 48 Action n Notes Maintain Self-Refresh Exit Self-Refresh 1 Maintain Power Down Self Refresh Entry Active Power Down Entry 1. Deselect or NOP commands should be issued on any clock edges occurring during the Self Refresh Exit (tXSNR) period. A minimum of 200 clock cycles are needed before applying a read command to allow the DLL to lock to the input clock. REV 1.1 Jun 29, 2005 47 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Truth Table 3: Current State Bank n - Command to Bank n (Same Bank) Current State Any Idle Row Active Read (Auto Precharge Disabled) Write (Auto Precharge Disabled) CS RAS CAS WE Command Action Notes H X X X Deselect NOP. Continue previous operation 1-6 L H H H No Operation NOP. Continue previous operation 1-6 L L H H Active Select and activate row 1-6 L L L H Auto Refresh L L L L Mode Register Set L H L H Read Select column and start Read burst 1-6, 10 L H L L Write Select column and start Write burst 1-6, 10 L L H L Precharge Deactivate row in bank(s) 1-6, 8 L H L H Read Select column and start new Read burst 1-6, 10 L L H L Precharge Truncate Read burst, start Precharge 1-6, 8 L H H L Burst Terminate Burst Terminate 1-6, 9 L H L H Read Select column and start Read burst 1-6, 10, 11 L H L L Write Select column and start Write burst 1-6, 10 L L H L Precharge 1-7 1-7 Truncate Write burst, start Precharge 1-6, 8, 11 1. This table applies when CKE n-1 was high and CKE n is high (see Truth Table 2: Clock Enable (CKE) and after tXSNR / tXSRD has been met (if the previous state was self refresh). 2. This table is bank-specific, except where noted, i.e., the current state is for a specific bank and the commands shown are those allowed to be issued to that bank when in that state. Exceptions are covered in the notes below. 3. Current state definitions: Idle: The bank has been precharged, and tRP has been met. Row Active: A row in the bank has been activated, and tRCD has been met. No data bursts/accesses and no register accesses are in progress. Read: A Read burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated. Write: A Write burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated. 4. The following states must not be interrupted by a command issued to the same bank. Precharging: Starts with registration of a Precharge command and ends when tRP is met. Once tRP is met, the bank is in the idle state. Row Activating: Starts with registration of an Active command and ends when tRCD is met. Once tRCD is met, the bank is in the "row active" state. Read w/Auto Precharge Enabled: Starts with registration of a Read command with Auto Precharge enabled and ends when tRP has been met. Once tRP is met, the bank is in the idle state. Write w/Auto Precharge Enabled: Starts with registration of a Write command with Auto Precharge enabled and ends when tRP has been met. Once tRP is met, the bank is in the idle state. Deselect or NOP commands, or allowable commands to the other bank should be issued on any clock edge occurring during these states. Allowable commands to the other bank are determined by its current state and according to Truth Table 4. 5. The following states must not be interrupted by any executable command; Deselect or NOP commands must be applied on each positive clock edge during these states. Refreshing: Starts with registration of an Auto Refresh command and ends when tRFC is met. Once tRFC is met, the DDR SDRAM is in the "all banks idle" state. Accessing Mode Register: Starts with registration of a Mode Register Set command and ends when tMRD has been met. Once tMRD is met, the DDR SDRAM is in the "all banks idle" state. Precharging All: Starts with registration of a Precharge All command and ends when tRP is met. Once tRP is met, all banks is in the idle state. 6. All states and sequences not shown are illegal or reserved. 7. Not bank-specific; requires that all banks are idle. 8. May or may not be bank-specific; if all/any banks are to be precharged, all/any must be in a valid state for precharging. 9. Not bank-specific; Burst terminate affects the most recent Read burst, regardless of bank. 10. Reads or Writes listed in the Command/Action column include Reads or Writes with Auto Precharge enabled and Reads or Writes with Auto Precharge disabled. 11. Requires appropriate DM masking. REV 1.1 Jun 29, 2005 48 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Truth Table 4: Current State Bank n - Command to Bank m (Different bank) (Part 1 of 2) Current State Any Idle Row Activating, Active, or Precharging Read (Auto Precharge Disabled) Write (Auto Precharge Disabled) CS RAS CAS WE Command Action Notes H X X X Deselect NOP/continue previous operation 1-6 L H H H No Operation NOP/continue previous operation 1-6 X X X X Any Command Otherwise Allowed to Bank m L L H H Active Select and activate row 1-6 L H L H Read Select column and start Read burst 1-7 L H L L Write Select column and start Write burst 1-7 L L H L Precharge L L H H Active Select and activate row 1-6 L H L H Read Select column and start new Read burst 1-7 L L H L Precharge L L H H Active Select and activate row 1-6 L H L H Read Select column and start Read burst 1-8 L H L L Write Select column and start new Write burst 1-7 L L H L Precharge 1-6 1-6 1-6 1-6 1. This table applies when CKE n-1 was high and CKE n is high (see Truth Table 2: Clock Enable (CKE) and after tXSNR / tXSRD has been met (if the previous state was self refresh). 2. This table describes alternate bank operation, except where noted, i.e., the current state is for bank n and the commands shown are those allowed to be issued to bank m (assuming that bank m is in such a state that the given command is allowable). Exceptions are covered in the notes below. 3. Current state definitions: Idle: The bank has been precharged, and tRP has been met. Row Active: A row in the bank has been activated, and tRCD has been met. No data bursts/accesses and no register accesses are in progress. Read: A Read burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated. Write: A Write burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated. Read with Auto Precharge Enabled: See note 10. Write with Auto Precharge Enabled: See note 10. 4. Auto Refresh and Mode Register Set commands may only be issued when all banks are idle. 5. A Burst Terminate command cannot be issued to another bank; it applies to the bank represented by the current state only. 6. All states and sequences not shown are illegal or reserved. 7. Reads or Writes listed in the Command/Action column include Reads or Writes with Auto Precharge enabled and Reads or Writes with Auto Precharge disabled. 8. Requires appropriate DM masking. 9. A Write command may be applied after the completion of data output. 10. The Read with Auto Precharge enabled or Write with Auto Precharge enabled states can each be broken into two parts: the access period and the precharge period. For Read with Auto Precharge, the precharge period is defined as if the same burst was executed with Auto Precharge disabled and then followed with the earliest possible Precharge command that still accesses all of the data in the burst. For Write with Auto Precharge, the precharge period begins when tWR ends, with tWR measured as if Auto Precharge was disabled. The access period starts with registration of the command and ends where the precharge period (or tRP) begins. During the precharge period of the Read with Auto Precharge Enabled or Write with Auto Precharge Enabled states, Active, Precharge, Read, and Write commands to the other bank may be applied; during the access period, only Active and Precharge commands to the other bank may be applied. In either case, all other related limitations apply (e.g. contention between Read data and Write data must be avoided). REV 1.1 Jun 29, 2005 49 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Truth Table 4: Current State Bank n - Command to Bank m (Different bank) (Part 2 of 2) Current State Read (With Auto Precharge) Write (With Auto Precharge) CS RAS CAS WE Command L L H H Active Select and activate row Action Notes L H L H Read Select column and start new Read burst L H L L Write Select column and start Write burst L L H L Precharge L L H H Active Select and activate row L H L H Read Select column and start Read burst 1-7,10 L H L L Write Select column and start new Write burst 1-7,10 L L H L Precharge 1-6 1-7,10 1-7,9,10 1-6 1-6 1-6 1. This table applies when CKE n-1 was high and CKE n is high (see Truth Table 2: Clock Enable (CKE) and after tXSNR / tXSRD has been met (if the previous state was self refresh). 2. This table describes alternate bank operation, except where noted, i.e., the current state is for bank n and the commands shown are those allowed to be issued to bank m (assuming that bank m is in such a state that the given command is allowable). Exceptions are covered in the notes below. 3. Current state definitions: Idle: The bank has been precharged, and tRP has been met. Row Active: A row in the bank has been activated, and tRCD has been met. No data bursts/accesses and no register accesses are in progress. Read: A Read burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated. Write: A Write burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated. Read with Auto Precharge Enabled: See note 10. Write with Auto Precharge Enabled: See note 10. 4. Auto Refresh and Mode Register Set commands may only be issued when all banks are idle. 5. A Burst Terminate command cannot be issued to another bank; it applies to the bank represented by the current state only. 6. All states and sequences not shown are illegal or reserved. 7. Reads or Writes listed in the Command/Action column include Reads or Writes with Auto Precharge enabled and Reads or Writes with Auto Precharge disabled. 8. Requires appropriate DM masking. 9. A Write command may be applied after the completion of data output. 10. The Read with Auto Precharge enabled or Write with Auto Precharge enabled states can each be broken into two parts: the access period and the precharge period. For Read with Auto Precharge, the precharge period is defined as if the same burst was executed with Auto Precharge disabled and then followed with the earliest possible Precharge command that still accesses all of the data in the burst. For Write with Auto Precharge, the precharge period begins when tWR ends, with tWR measured as if Auto Precharge was disabled. The access period starts with registration of the command and ends where the precharge period (or tRP) begins. During the precharge period of the Read with Auto Precharge Enabled or Write with Auto Precharge Enabled states, Active, Precharge, Read, and Write commands to the other bank may be applied; during the access period, only Active and Precharge commands to the other bank may be applied. In either case, all other related limitations apply (e.g. contention between Read data and Write data must be avoided). REV 1.1 Jun 29, 2005 50 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Simplified State Diagram Power Applied Power On Self Refresh Precharge Preall REFS REFSX MRS EMRS MRS CKEH Active Power Down Auto Refresh REFA Idle CKEL ACT Precharge Power Down CKEH CKEL Burst Stop Row Active Write Write A Write Read Read A Read Read Read A Write A PRE Write A PRE PRE PRE Read A Read A Precharge Preall Automatic Sequence Command Sequence PREALL = Precharge All Banks MRS = Mode Register Set EMRS = Extended Mode Register Set REFS = Enter Self Refresh REFSX = Exit Self Refresh REFA = Auto Refresh REV 1.1 Jun 29, 2005 CKEL = Enter Power Down CKEH = Exit Power Down ACT = Active Write A = Write with Autoprecharge Read A = Read with Autoprecharge PRE = Precharge 51 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Absolute Maximum Ratings Symbol VIN, VOUT Parameter Voltage on I/O pins relative to VSS Rating Units -0.5 to VDDQ+ 0.5 V VIN Voltage on Inputs relative to VSS -0.5 to +3.6 V VDD Voltage on VDD supply relative to VSS -0.5 to +3.6 V Voltage on VDDQ supply relative to VSS -0.5 to +3.6 V 0 to +70 C -55 to +150 C Power Dissipation 1.0 W Short Circuit Output Current 50 mA VDDQ TA TSTG PD IOUT Operating Temperature (Ambient) Storage Temperature (Plastic) Note: Stresses greater than those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress rating only, and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. DQS/DQ/DM Slew Rate Parameter DCS/DQ/DM input slew rate Symbol DCSLEW DDR400 (5T) DDR333 (6K) DDR266 (75B) Min Max Min Max Min Max TBD TBD TBD TBD TBD TBD Unit Notes V/ns 1, 2 1. Measured between V IH (DC), V IL (DC), and V IL (DC), V IH (DC). 2. DQS, DQ, and DM input slew rate is specified to prevent double clocking of data and preserve setup and hold times. Signal transition through the DC region must be monotonic. REV 1.1 Jun 29, 2005 52 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Capacitance Parameter Input Capacitance: CK, CK Delta Input Capacitance: CK, CK Symbol Min. Max. Units Notes CI1 2.0 3.0 pF 1 0.25 pF 1 3.0 pF 1 0.5 pF 1 5.0 pF 1, 2 0.5 pF 1 delta CI1 Input Capacitance: All other input-only pins (except DM) 2.0 CI2 Delta Input Capacitance: All other input-only pins (except DM) delta CI2 Input/Output Capacitance: DQ, DQS, DM CIO Delta Input/Output Capacitance: DQ, DQS, DM 4.0 delta CIO 1. VDDQ = VDD = 2.5V 0.2V (minimum range to maximum range), f = 100MHz, TA = 25C, VODC = VDDQ/2, VOPeak -Peak = 0.2V. 2. Although DM is an input-only pin, the input capacitance of this pin must model the input capacitance of the DQ and DQS pins. This is required to match input propagation times of DQ, DQS and DM in the system. DC Electrical Characteristics and Operating Conditions (0C TA 70xC; VDDQ = 2.5V 0.2V, VDD = + 2.5V 0.2V, see AC Characteristics) Symbol Min Max Units Notes Supply Voltage 2.3 2.7 V 1 VDDQ I/O Supply Voltage 2.3 2.7 V 1 VSS, VSSQ Supply Voltage I/O Supply Voltage 0 0 V I/O Reference Voltage 0.49 x VDDQ 0.51 x VDDQ V 1, 2 I/O Termination Voltage (System) VREF - 0.04 VREF + 0.04 V 1, 3 VIH(DC) Input High (Logic1) Voltage VREF + 0.15 VDDQ + 0.3 V 1 VIL(DC) Input Low (Logic0) Voltage - 0.3 VREF - 0.15 V 1 VIN(DC) Input Voltage Level, CK and CK Inputs - 0.3 VDDQ + 0.3 V 1 VID(DC) Input Differential Voltage, CK and CK Inputs 0.30 VDDQ + 0.6 V 1, 4 VIX(DC) Input Crossing Point Voltage, CK and CK Inputs 0.30 VDDQ + 0.6 V 1, 4 VIRatio V-I Matching Pullup Current to Pulldown Current Ratio 0.71 1.4 Input Leakage Current Any input 0V VIN VDD; (All other pins not under test = 0V) -5 5 A 1 Output Leakage Current (DQs are disabled; 0V Vout VDDQ -5 5 A 1 mA 1 VDD VREF VTT II IOZ IOH IOL Parameter Output Current: Nominal Strength Driver High current (VOUT= VDDQ -0.373V, min VREF, min VTT) Low current (VOUT= 0.373V, max VREF, max VTT) 5 - 16.8 16.8 1. Inputs are not recognized as valid until VREF stabilizes. 2. VREF is expected to be equal to 0.5 VDDQ of the transmitting device, and to track variations in the DC level of the same. Peak-to-peak noise on VREF may not exceed 2% of the DC value. 3. VTT is not applied directly to the device. VTT is a system supply for signal termination resistors, is expected to be set equal to VREF, and must track variations in the DC level of VREF. 4. VID is the magnitude of the difference between the input level on CK and the input level on CK. 5. The ratio of the pullup current to the pulldown current is specified for the same temperature and voltage, over the entire temperature and voltage range, for device drain to source voltages for 0.25 volts to 1.0 volts. For a given output, it represents the maximum difference between pullup and pulldown drivers due to process variation. REV 1.1 Jun 29, 2005 53 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM DC Electrical Characteristics and Operating Conditions (0C TA 70xC; VDDQ = 2.5V 0.2V, VDD = + 2.5V 0.2V, see AC Characteristics) Symbol IOHW IOLW Parameter Min Max Units Notes mA 1 - 9.0 Output Current: Half- Strength Driver High current (VOUT= VDDQ -0.763V, min VREF, min VTT) Low current (VOUT= 0.763V, max VREF, max VTT) 9.0 1. Inputs are not recognized as valid until VREF stabilizes. 2. VREF is expected to be equal to 0.5 VDDQ of the transmitting device, and to track variations in the DC level of the same. Peak-to-peak noise on VREF may not exceed 2% of the DC value. 3. VTT is not applied directly to the device. VTT is a system supply for signal termination resistors, is expected to be set equal to VREF, and must track variations in the DC level of VREF. 4. VID is the magnitude of the difference between the input level on CK and the input level on CK. 5. The ratio of the pullup current to the pulldown current is specified for the same temperature and voltage, over the entire temperature and voltage range, for device drain to source voltages for 0.25 volts to 1.0 volts. For a given output, it represents the maximum difference between pullup and pulldown drivers due to process variation. Normal Strength Driver Pulldown and Pullup Characteristics 1. The full variation in driver pulldown current from minimum to maximum process, temperature and voltage will lie within the outer bounding lines of the V-I curve. 2. It is recommended that the "typical" IBIS pulldown V-I curve lie within the shaded region of the V-I curve. Normal Strength Driver Pulldown Characteristics 140 IOUT (mA) Maximum Typical High Typical Low Minimum 0 0 2.7 VOUT (V) 3. The full variation in driver pullup current from minimum to maximum process, temperature and voltage will lie within the outer bounding lines of the V-I curve. 4. It is recommended that the "typical" IBIS pullup V-I curve lie within the shaded region of the V-I curve. REV 1.1 Jun 29, 2005 54 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Normal Strength Driver Pullup Characteristics 0 Minimum IOUT (mA) Typical Low Typical High Maximum -200 0 VOUT (V) 2.7 5. The full variation in the ratio of the maximum to minimum pullup and pulldown current will not exceed 1.7, for device drain to source voltages from 0.1 to 1.0. 6. The full variation in the ratio of the "typical" IBIS pullup to "typical" IBIS pulldown current should be unity + 10%, for device drain to source voltages from 0.1 to 1.0. This specification is a design objective only. It is not guaranteed. 7. These characteristics are intended to obey the SSTL_2 class II standard. 8. This specification is intended for DDR SDRAM only. REV 1.1 Jun 29, 2005 55 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Normal Strength Driver Pulldown and Pullup Currents Pulldown Current (mA) Pullup Current (mA) Voltage (V) Typical Low Typical High Min Max Typical Low Typical High Min Max 0.1 6.0 6.8 4.6 9.6 -6.1 -7.6 -4.6 -10.0 0.2 12.2 13.5 9.2 18.2 -12.2 -14.5 -9.2 -20.0 0.3 18.1 20.1 13.8 26.0 -18.1 -21.2 -13.8 -29.8 0.4 24.1 26.6 18.4 33.9 -24.0 -27.7 -18.4 -38.8 0.5 29.8 33.0 23.0 41.8 -29.8 -34.1 -23.0 -46.8 0.6 34.6 39.1 27.7 49.4 -34.3 -40.5 -27.7 -54.4 0.7 39.4 44.2 32.2 56.8 -38.1 -46.9 -32.2 -61.8 0.8 43.7 49.8 36.8 63.2 -41.1 -53.1 -36.0 -69.5 0.9 47.5 55.2 39.6 69.9 -43.8 -59.4 -38.2 -77.3 1.0 51.3 60.3 42.6 76.3 -46.0 -65.5 -38.7 -85.2 1.1 54.1 65.2 44.8 82.5 -47.8 -71.6 -39.0 -93.0 1.2 56.2 69.9 46.2 88.3 -49.2 -77.6 -39.2 -100.6 1.3 57.9 74.2 47.1 93.8 -50.0 -83.6 -39.4 -108.1 1.4 59.3 78.4 47.4 99.1 -50.5 -89.7 -39.6 -115.5 1.5 60.1 82.3 47.7 103.8 -50.7 -95.5 -39.9 -123.0 1.6 60.5 85.9 48.0 108.4 -51.0 -101.3 -40.1 -130.4 1.7 61.0 89.1 48.4 112.1 -51.1 -107.1 -40.2 -136.7 1.8 61.5 92.2 48.9 115.9 -51.3 -112.4 -40.3 -144.2 1.9 62.0 95.3 49.1 119.6 -51.5 -118.7 -40.4 -150.5 2.0 62.5 97.2 49.4 123.3 -51.6 -124.0 -40.5 -156.9 2.1 62.9 99.1 49.6 126.5 -51.8 -129.3 -40.6 -163.2 2.2 63.3 100.9 49.8 129.5 -52.0 -134.6 -40.7 -169.6 2.3 63.8 101.9 49.9 132.4 -52.2 -139.9 -40.8 -176.0 2.4 64.1 102.8 50.0 135.0 -52.3 -145.2 -40.9 -181.3 2.5 64.6 103.8 50.2 137.3 -52.5 -150.5 -41.0 -187.6 2.6 64.8 104.6 50.4 139.2 -52.7 -155.3 -41.1 -192.9 2.7 65.0 105.4 50.5 140.8 -52.8 -160.1 -41.2 -198.2 Normal Strength Driver Evaluation Conditions REV 1.1 Jun 29, 2005 Typical Minimum Maximum Temperature (Tambient) 25 C 70 C 0 C VDDQ 2.5V 2.3V 2.7V Process conditions typical process slow-slow process fast-fast process 56 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM AC Characteristics (Notes 1-5 apply to the following Tables; Electrical Characteristics and DC Operating Conditions, AC Operating Conditions, IDD Specifications and Conditions, and Electrical Characteristics and AC Timing.) 1. All voltages referenced to VSS. 2. Tests for AC timing, IDD, and electrical, AC and DC characteristics, may be conducted at nominal reference/supply voltage levels, but the related specifications and device operation are guaranteed for the full voltage range specified. 3. Outputs measured with equivalent load. Refer to the AC Output Load Circuit below. 4. AC timing and IDD tests may use a VIL to VIH swing of up to 1.5V in the test environment, but input timing is still referenced to VREF (or to the crossing point for CK, CK), and parameter specifications are guaranteed for the specified AC input levels under normal use conditions. The minimum slew rate for the input signals is 1V/ns in the range between VIL(AC) and VIH(AC). 5. The AC and DC input level specifications are as defined in the SSTL_2 Standard (i.e. the receiver effectively switches as a result of the signal crossing the AC input level, and remains in that state as long as the signal does not ring back above (below) the DC input low (high) level. AC Output Load Circuit Diagrams VTT 50 Output (VOUT) Timing Reference Point 30pF REV 1.1 Jun 29, 2005 57 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM AC Input Operating Conditions (0 C TA 70 C; VDDQ = VDD = 2.5V 0.2V (DDR333); VDDQ = VDD = 2.6V 0.1V (DDR400); See AC Characteristics) Symbol Parameter/Condition VIH(AC) Input High (Logic 1) Voltage, DQ, DQS, and DM Signals VIL(AC) Input Low (Logic 0) Voltage, DQ, DQS, and DM Signals VID(AC) Input Differential Voltage, CK and CK Inputs VIX(AC) Input Crossing Point Voltage, CK and CK Inputs 1. 2. 3. 4. Min Max Unit Notes V 1, 2 VREF - 0.31 V 1, 2 0.62 VDDQ + 0.6 V 1, 2, 3 0.5*VDDQ - 0.2 0.5*VDDQ + 0.2 V 1, 2, 4 VREF + 0.31 Input slew rate = 1V/ns. Inputs are not recognized as valid until VREF stabilizes. VID is the magnitude of the difference between the input level on CK and the input level on CK. The value of VIX is expected to equal 0.5*VDDQ of the transmitting device and must track variations in the DC level of the same. IDD Specifications and Conditions (0 C TA 70 C; VDDQ = VDD = 2.5V 0.2V (DDR333); VDDQ = VDD = 2.6V 0.1V (DDR400); See AC Characteristics) DDR400 DDR333 DDR266( (5T) (6K) 75B) tCK=5ns tCK=6ns tCK=75ns Unit Notes 57 mA 1 72 50 mA 1 4 4 3 mA 1 Idle Standby Current: CS VIH (min); all banks idle; CKE VIH (min); address and control inputs changing once per clock cycle 29 25 20 mA 1 IDD3P Active Power Down Standby Current: one bank active; Power Down mode; CKE VIL (max) 11 10 9 mA 1 IDD3N Active Standby Current: one bank; active / precharge; CS VIH (min); CKE VIH (min); tRC = tRAS (max); DQ, DM, and DQS inputs changing twice per clock cycle; address and control inputs changing once per clock cycle 46 39 27 mA 1 IDD4R Operating Current: one bank; Burst = 2; reads; continuous burst; address and control inputs changing once per clock cycle; DQ and DQS outputs changing twice per clock cycle; CL = 2.5; IOUT = 0mA 105 87 57 mA 1 IDD4W Operating Current: one bank; Burst = 2; writes; continuous burst; address and control inputs changing once per clock cycle; DQ and DQS inputs changing twice per clock cycle; CL = 2.5 119 98 63 mA 1 IDD5 Auto-Refresh Current: tRC = tRFC (min) 124 118 102 mA 1 IDD6 Self-Refresh Current: CKE 0.2V 2 2 1.3 mA 1, 2 IDD7 Operating current: four bank; four bank interleaving with BL = 4, address and control inputs randomly changing; 50% of data changing at every transfer; t RC = t RC (min); I OUT = 0mA. 246 207 157 mA 1 Symbol Parameter/Condition IDD0 Operating Current: one bank; active / precharge; tRC = tRC (min); DQ, DM, and DQS inputs changing twice per clock cycle; address and control inputs changing once per clock cycle 76 68 IDD1 Operating Current: one bank; active / read / precharge; Burst = 2; tRC = tRC (min); CL = 2.5; IOUT = 0mA; address and control inputs changing once per clock cycle 79 IDD2P Precharge Power Down Standby Current: all banks idle; Power Down mode; CKE VIL (max) IDD2N 1. IDD specifications are tested after the device is properly initialized. 2. Enables on-chip refresh and address counters. Device testing was performed with x16 wide devices. REV 1.1 Jun 29, 2005 58 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Electrical Characteristics & AC Timing - Absolute Specifications (0 C TA 70 C; VDDQ = VDD = 2.5V 0.2V (DDR333); VDDQ = VDD = 2.6V 0.1V (DDR400); See AC Characteristics) tAC tDQSCK DDR400 (5T) Parameter Symbol (Part 1 of 2) DDR333 (6K) DDR266 (75B) Unit Notes + 0.75 ns 1-4 - 0.75 + 0.75 ns 1-4 Min Max Min Max Min Max DQ output access time from CK/CK - 0.65 + 0.65 - 0.70 + 0.70 - 0.75 DQS output access time from CK/CK - 0.55 + 0.55 - 0.60 + 0.60 tCH CK high-level width 0.45 0.55 0.45 0.55 0.45 0.55 tCK 1-4 tCL CK low-level width 0.45 0.55 0.45 0.55 0.45 0.55 tCK 1-4 CL = 2 - - 6 12 7.5 12 CL = 2.5 5 12 6 8 10 8 ns 1-4 CL=3 5 8 - - - - Clock cycle time tCK tDH DQ and DM input hold time 0.40 0.45 0.5 ns 1-4, 15, 16 tDS DQ and DM input setup time 0.40 0.45 0.5 ns 1-4, 15, 16 tIPW Input pulse width 2.2 2.2 2.2 ns 2-4, 12 tDIPW DQ and DM input pulse width (each input) 1.75 1.75 1.75 ns 1-4 tHZ Data-out high-impedance time from CK/CK - 0.65 + 0.65 - 0.7 + 0.7 - 0.75 + 0.75 ns 1-4, 5 tLZ Data-out low-impedance time from CK/CK - 0.65 + 0.65 - 0.7 + 0.7 - 0.75 + 0.75 ns 1-4, 5 + 0.5 ns 1-4 tDQSQ + 0.40 DQS-DQ skew (DQS & associated DQ signals) + 0.45 tHP Minimum half clk period for any given cycle; defined by clk high (tCH) or clk low (tCL) time min (tCL, tCH) min (tCL, tCH) min (tCL, tCH) tCK 1-4 tQH Data output hold time from DQS tHP tQHS tHP tQHS tHP tQHS tCK 1-4 tQHS Data hold Skew Factor 0.75 tCK 1-4 tDQSS Write command to 1st DQS latching transition 0.75 1.25 tCK 1-4 tDQSH DQS input high pulse width (write cycle) 0.35 0.35 0.35 tCK 1-4 tDQSL DQS input low pulse width (write cycle) 0.35 0.35 0.35 tCK 1-4 tDSS DQS falling edge to CK setup time (write cycle) 0.2 0.2 0.2 tCK 1-4 tDSH DQS falling edge hold time from CK (write cycle) 0.2 0.2 0.2 tCK 1-4 tMRD Mode register set command cycle time 12 12 12 ns 1-4 Write preamble setup time 0 0 0 ns 1-4, 7 tCK 1-4, 6 tWPRES 0.5 1.25 0.55 0.75 1.25 0.75 tWPST Write postamble 0.40 tWPRE Write preamble 0.25 0.25 0.25 tCK 1-4 tIH Address and control input hold time (fast slew rate) 0.6 0.75 0.9 ns 2-4, 9, 11, 12 tIS Address and control input setup time (fast slew rate) 0.6 0.75 0.9 ns 2-4, 9, 11, 12 tIH Address and control input hold time (slow slew rate) 0.65 0.8 1.0 ns 2-4, 10, 11, 12, 14 REV 1.1 Jun 29, 2005 0.60 0.40 0.60 0.40 0.60 59 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Electrical Characteristics & AC Timing - Absolute Specifications (0 C TA 70 C; VDDQ = VDD = 2.5V 0.2V (DDR333); VDDQ = VDD = 2.6V 0.1V (DDR400); See AC Characteristics) DDR400 (5T) Parameter Symbol Min Max (Part 2 of 2) DDR333 (6K) Min DDR266 (75B) Max Min Unit Notes ns 2-4, 10, 11, 12, 14 Max Address and control input setup time (slow slew rate) 0.65 tRPRE Read preamble 4.5 5.5 0.9 1.1 0.9 1.1 ns 1-4 tRPST Read postamble 2.0 3.0 0.40 0.60 0.40 0.60 ns 1-4 tRAS Active to Precharge 42 ns 1-4 tRC Active to Active/Auto-refresh command period 55 60 65 ns 1-4 tRFC Auto-refresh to Active/Auto-refresh command period 65 72 75 ns 1-4 tRCD Active to Read or Write delay 15 18 20 ns 1-4 tRAP Active to Read Command with Autoprecharge min (tRCD, tRAS) min (tRCD, tRAS) min (tRCD, tRAS) ns 1-4 tRP Precharge command period 15 18 20 ns 1-4 tRRD Active bank A to Active bank B command 12 12 15 ns 1-4 tWR Write recovery time 15 15 15 ns 1-4 (tWR/tCK ) + (tRP/tCK) (tWR/tCK ) + (tRP/tCK) (tWR/tCK ) + (tRP/tCK) tCK 1-4, 13 tIS 0.8 40 0.9 42 tDAL Auto precharge write recovery + precharge time tWTR Internal write to read command delay 12 12 12 ns 1-4 tPDEX Power down exit time 6 6 6 ns 1-4 tXSNR Exit self-refresh to non-read command 75 75 75 ns 1-4 tXSRD Exit self-refresh to read command 200 200 200 tCK 1-4 tREFI Average Periodic Refresh Interval s 1-4, 8 REV 1.1 Jun 29, 2005 7.8 7.8 7.8 60 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Electrical Characteristics & AC Timing - Absolute Specifications Notes 1. Input slew rate = 1V/ns. 2. The CK/CK input reference level (for timing reference to CK/CK) is the point at which CK and CK cross; the input reference level for signals other than CK/CK is VREF. 3. Inputs are not recognized as valid until VREF stabilizes. 4. The Output timing reference level, as measured at the timing reference point indicated in AC Characteristics (Note 3) is VTT. 5. tHZ and tLZ transitions occur in the same access time windows as valid data transitions. These parameters are not referred to a specific voltage level, but specify when the device is no longer driving (HZ), or begins driving (LZ). 6. The maximum limit for this parameter is not a device limit. The device operates with a greater value for this parameter, but system performance (bus turnaround) degrades accordingly. 7. The specific requirement is that DQS be valid (high, low, or some point on a valid transition) on or before this CK edge. A valid transition is defined as monotonic and meeting the input slew rate specifications of the device. When no writes were previously in progress on the bus, DQS will be transitioning from Hi-Z to logic LOW. If a previous write was in progress, DQS could be HIGH, LOW, or transitioning from high to low at this time, depending on tDQSS. 8. A maximum of eight Autorefresh commands can be posted to any given DDR SDRAM device. 9. For command/address input slew rate 1.0V/ns. Slew rate is measured between VOH (AC) and VOL (AC). 10. For command/address input slew rate 0.5V/ns and < 1.0V/ns. Slew rate is measured between VOH (AC) and VOL (AC). 11. CK/CK slew rates are 1.0V/ns. 12. These parameters guarantee device timing, but they are not necessarily tested on each device, and they may be guaranteed by design or tester characterization. 13. For each of the terms in parentheses, if not already an integer, round to the next highest integer. tCK is equal to the actual system clock cycle time. For example, for DDR266 at CL = 2.5, tDAL = (15ns/7.5ns) + (20ns/7.5ns) = 2 + 3 = 5. REV 1.1 Jun 29, 2005 61 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM 14. An input setup and hold time derating table is used to increase tIS and tIH in the case where the input slew rate is below 0.5 V/ns. Input Slew Rate delta (tIS) delta (tIH) Unit Notes 0.5 V/ns 0 0 ps 1,2 0.4 V/ns +50 0 ps 1,2 0.3 V/ns +100 0 ps 1,2 1. Input slew rate is based on the lesser of the slew rates determined by either V IH (AC) to V IL (AC) or V IH (DC) to V IL (DC), similarly for rising transitions. 2. These derating parameters may be guaranteed by design or tester characterization and are not necessarily tested on each device. 15. An input setup and hold time derating table is used to increase tDS and tDH in the case where the I/O slew rate is below 0.5 V/ns. Input Slew Rate delta (tDS) delta (tDH) Unit Notes 0.5 V/ns 0 0 ps 1,2 0.4 V/ns +75 +75 ps 1,2 0.3 V/ns +150 +150 ps 1,2 1. I/O slew rate is based on the lesser of the slew rates determined by either V IH (AC) to V IL (AC) or V IH (DC) to V IL (DC), similarly for rising transitions. 2. These derating parameters may be guaranteed by design or tester characterization and are not necessarily tested on each device. 16. An I/O Delta Rise, Fall Derating table is used to increase tDS and tDH in the case where DQ, DM, and DQS slew rates differ. Input Slew Rate delta (tDS) delta (tDH) Unit Notes 0.0 V/ns 0 0 ps 1,2,3,4 0.25 V/ns +50 +50 ps 1,2,3,4 0.5 V/ns +100 +100 ps 1,2,3,4 1. Input slew rate is based on the lesser of the slew rates determined by either V IH (AC) to V IL (AC) or V IH (DC) to V IL (DC), similarly for rising transitions. 2. Input slew rate is based on the larger of AC to AC delta rise, fall rate and DC to DC delta rise, fall rate. 3. The delta rise, fall rate is calculated as: [1/(slew rate 1)] - [1/(slew rate 2)] For example: slew rate 1 = 0.5 V/ns; slew rate 2 = 0.4 V/ns Delta rise, fall = (1/0.5) - (1/0.4) [ns/V] = -0.5 ns/V Using the table above, this would result in an increase in t DS and t DH of 100 ps. 4. These derating parameters may be guaranteed by design or tester characterization and are not necessarily tested on each device. REV 1.1 Jun 29, 2005 62 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Data Input (Write) (Timing Burst Length = 4) tDSL tDSH DQS tDH tDS DI n DQ tDH tDS DM DI n = Data In for column n. 3 subsequent elements of data in are applied in programmed order following DI n. Data Output (Read) Don't Care (Timing Burst Length = 4) CK CK tHP tHP tHP tHP1 tHP2 tHP3 tHP4 DQS tDQSQ tQH2 tQH1 DQ tDQSQ tDQSQ tQH4 tQH3 tDQSQ tHP is the half cycle pulse width for each half cycle clock. tHP is referenced to the clock duty cycle only and not to the data strobe (DQS) duty cycle. Data Output hold time from Data Strobe is shown as tQH. tQH is a function of the clock high or low time (tHP) for that given clock cycle. Note correlation of tHP to tQH in the diagram above (tHP1 to tQH1, etc.). tDQSQ (max) occurs when DQS is the earliest among DQS and DQ signals to transition. REV 1.1 Jun 29, 2005 63 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. REV 1.1 Jun 29, 2005 tVTD High-Z High-Z 200s Power-up: VDD and CK stable LVCMOS LOW LEVEL Don't Care DQ DQS BA0, BA1 A10 A0-A9, A11 DM Command CKE CK CK VREF VTT (System*) VDDQ VDD tIH tIH NOP tIS tIS tCH tIS tIH PRE tCL tIH tIH tIH BA1=L BA0=H tIS CODE tIS CODE tIS EMRS BA1=L BA0=L CODE CODE MRS tIS tIH PRE tRP ALL BANKS tMRD Load Mode Register, Reset DLL tMRD Extended Mode Register Set ALL BANKS tCK AR tRFC AR BA1=L BA0=L CODE CODE MRS tMRD Load Mode Register (with A8 = L) tRFC 200 cycles of CK** The two Autorefresh commands may be moved to follow the first MRS, but precede the second Precharge All command. ** tMRD is required before any command can be applied and 200 cycles of CK are required before a Read command can be applied. * VTT is not applied directly to the device, however tVTD must be greater than or equal to zero to avoid device latchup. BA RA RA ACT N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Initialize and Mode Register Sets 64 NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. (c) NANYA TECHNOLOGY CORP. All rights reserved. REV 1.1 Jun 29, 2005 tIH tIH tIH VALID tIS VALID* tIS tIS tCK Enter Power Down Mode NOP tIS tCH tCL No column accesses are allowed to be in progress at the time power down is entered. * = If this command is a Precharge (or if the device is already in the idle state) then the power down mode shown is Precharge power down. If this command is an Active (or if at least one row is already active), then the power down mode shown is Active power down. DM DQ DQS ADDR Command CKE CK CK Exit Power Down Mode NOP tIS tPDEX Don't Care VALID VALID N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Power Down Mode 65 NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. (c) NANYA TECHNOLOGY CORP. All rights reserved. REV 1.1 Jun 29, 2005 tIH tIH NOP AR NOP AR NOP VALID tRFC NOP ACT tIH BANK(S) tIS ONE BANK PRE = Precharge; ACT = Active; RA = Row address; BA = Bank address; AR = Autorefresh. NOP commands are shown for ease of illustration; other valid commands may be possible at these times. DM, DQ, and DQS signals are all don't care/high-Z for operations shown. DM DQ DQS BA0, BA1 A10 Don't Care BA RA RA ALL BANKS NOP tRFC A9, A11,A12 PRE VALID tCL RA NOP tIS tIS tCK tRP A0-A8 Command CKE CK CK tCH N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Auto Refresh Mode 66 NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. (c) NANYA TECHNOLOGY CORP. All rights reserved. REV 1.1 Jun 29, 2005 DM DQ DQS ADDR Command CKE CK CK NOP tIH tIH tCH tCK tIS AR Enter Self Refresh Mode tCL * = Device must be in the all banks idle state before entering Self Refresh Mode. ** = tXSNR is required before any non-read command can be applied, and tXSRD (200 cycles of CK). are required before a Read command can be applied. tIS tIS tRP* Exit Self Refresh Mode NOP tXSRD, tXSRN tIS 200 cycles tIH Don't Care VALID tIS VALID Clock must be stable before exiting Self Refresh Mode N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Self Refresh Mode 67 NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. (c) NANYA TECHNOLOGY CORP. All rights reserved. REV 1.1 Jun 29, 2005 Case 2: tAC/tDQSCK = max Case 1: tAC/tDQSCK = min tIH tIH NOP tIS tIS tIH tIH tIH BA x tIS DIS AP tIS COL n tIS Read CL=2 tLZ (max) tLZ (max) tRPRE NOP DO n tAC (max) DO n tAC (min) BA x* ONE BANK ALL BANKS PRE tCL tLZ (min) tRPRE NOP tCH NOP tDQSCK (max) NOP commands are shown for ease of illustration; other commands may be valid at these times. DIS AP = Disable Auto Precharge. * = Don't care if A10 is High at this point. PRE = Precharge; ACT = Active; RA = Row address; BA = Bank address. BA x RA RA ACT tHZ (max) tRPST tHZ (min) tIH tDQSCK (min) tRPST tRP 3 subsequent elements of data out are provided in the programmed order following DO n. DO n = data out from column n. DQ DQS DQ DQS DM BA0, BA1 A10 A0-A9, A11, A12 Command CKE CK CK tCK NOP VALID NOP VALID Don't Care NOP VALID N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Read without Auto Precharge (Burst Length = 4) 68 NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. (c) NANYA TECHNOLOGY CORP. All rights reserved. REV 1.1 Jun 29, 2005 Case 2: tAC/tDQSCK = max Case 1: tAC/tDQSCK = min DQ DQS DQ DQS DM BA0, BA1 A10 A0-A9, A11, A12 Command CKE CK CK tIH tIH tIH tIH tIH BA x tIS EN AP tIS COL n tIS Read tLZ (max) tRPRE tLZ (max) CL=2 tHZ (min) NOP DO n tAC (max) DO n tAC (min) NOP tCL tLZ (min) tRPRE NOP tCH NOP BA x RA RA ACT tDQSCK (max) tHZ (max) tRPST tHZ (min) tIH tDQSCK (min) tRPST tRP NOP VALID DO n = data out from column n. 3 subsequent elements of data out are provided in the programmed order following DO n. EN AP = enable Auto Precharge. ACT = active; RA = row address. NOP commands are shown for ease of illustration; other commands may be valid at these times. NOP tIS tIS tCK NOP VALID Don't Care NOP VALID N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Read with Auto Precharge (Burst Length = 4) 69 NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. (c) NANYA TECHNOLOGY CORP. All rights reserved. REV 1.1 Jun 29, 2005 tIH tIH DQ DQS DQ BA x tIH tCK tRCD NOP tCH tIH tRAS BA x DIS AP tIS COL n Read tCL tLZ (max) NOP DO n tAC (max) DO n tAC (min) BA x* ONE BANK tLZ (max) tRPRE tLZ (min) CL=2 PRE ALL BANKS tRC tLZ (min) tRPRE NOP DO n = data out from column n. 3 subsequent elements of data out are provided in the programmed order following DO n. DIS AP = disable Auto Precharge. * = Don't care if A10 is High at this point. PRE = Precharge; ACT = Active; RA = Row address; BA = Bank address. NOP commands are shown for ease of illustration; other commands may be valid at these times. Case 2: tAC/tDQSCK = max Case 1: tAC/tDQSCK = min DQS DM BA0, BA1 tIS RA tIH A10 tIS ACT RA NOP tIS tIS A0-A9, A11, A12 Command CKE CK CK BA x RA RA ACT tHZ (max) tHZ (min) tRPST tDQSCK (max) tDQSCK (min) tRPST tRP NOP Don't Care NOP VALID N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Bank Read Access (Burst Length = 4) 70 NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. (c) NANYA TECHNOLOGY CORP. All rights reserved. REV 1.1 Jun 29, 2005 DM DQ DQS BA0, BA1 A10 A0-A9, A11, A12 Command CKE CK CK tIH tIH tIH tIH tWPRES tDQSS tIH BA x tIS DIS AP tIS COL n tIS Write DIn tDQSH tWPRE NOP tDQSL tCH tCL NOP tWPST tDSH NOP tIH NOP tWR PRE BA x* ONE BANK ALL BANKS tDQSS = min. DIn = Data in for column n. 3 subsequent elements of data in are applied in the programmed order following DIn. DIS AP = Disable Auto Precharge. * = Don't care if A10 is High at this point. PRE = Precharge; ACT = Active; RA = Row address; BA = Bank address. NOP commands are shown for ease of illustration; other valid commands may be possible at these times. NOP tIS tIS tCK NOP VALID tRP NOP Don't Care BA RA RA ACT N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Write without Auto Precharge (Burst Length = 4) 71 NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. (c) NANYA TECHNOLOGY CORP. All rights reserved. REV 1.1 Jun 29, 2005 DM DQ DQS BA0, BA1 A10 A0-A9, A11, A12 Command CKE CK CK tIH tIH tWPRE tWPRES tDQSS tIH BA x tIS EN AP tIS COL n tIS Write DIn tDQSH NOP tCH tDQSL NOP tCL tWPST tDSH NOP NOP VALID tWR DIn = Data in for column n. 3 subsequent elements of data in are applied in the programmed order following DIn. EN AP = Enable Auto Precharge. ACT = Active; RA = Row address; BA = Bank address. NOP commands are shown for ease of illustration; other valid commands may be possible at these times. tDQSS = min. tIH tIH NOP tIS tIS tCK NOP VALID tDAL NOP VALID tRP NOP Don't Care BA RA RA ACT N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Write with Auto Precharge (Burst Length = 4) 72 NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. (c) NANYA TECHNOLOGY CORP. All rights reserved. REV 1.1 Jun 29, 2005 tIH tIH DM DQ DQS BA0, BA1 tIH tIH tRCD NOP tCH tIH tWPRES BA x tDQSS DIS AP tIS Col n Write tCL DIn tDSH tDQSL tWPRE tDQSH NOP tRAS NOP tWPST NOP tDQSS = min. DI n = data in for column n. 3 subsequent elements of data in are applied in the programmed order following DI n. DIS AP = Disable Auto Precharge. * = don't care if A10 is High at this point. PRE = Precharge; ACT = Active; RA = Row address. NOP commands are shown for ease of illustration; other valid commands may be possible at these times. BA x tIS RA A10 tIS ACT RA NOP tIS tIS A0-A9, A11, A12 Command CKE CK CK tCK tWR NOP BA x ONE BANK ALL BANKS PRE Don't Care NOP VALID N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Bank Write Access (Burst Length = 4) 73 NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. (c) NANYA TECHNOLOGY CORP. All rights reserved. REV 1.1 Jun 29, 2005 DM DQ DQS BA0, BA1 A10 A0-A9, A11, A12 Command CKE CK CK tIH tIH tIH tIH tIH tWPRES BA x tIS tDQSS DIS AP tIS COL n tIS Write DIn tDQSH NOP tCH tDQSL tCL NOP tWPST tDSH NOP tWR NOP BA x* ONE BANK ALL BANKS PRE NOP VALID DI n = data in for column n. 3 subsequent elements of data in are applied in the programmed order following DI n (the second element of the 4 is masked). DIS AP = Disable Auto Precharge. * = Don't care if A10 is High at this point. PRE = Precharge; ACT = Active; RA = Row address; BA = Bank address. NOP commands are shown for ease of illustration; other valid commands may be possible at these times. tDQSS = min. NOP tIS tIS tCK tRP NOP Don't Care BA RA RA ACT N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Write DM Operation (Burst Length = 4) 74 NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. (c) NANYA TECHNOLOGY CORP. All rights reserved. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Package Dimensions (400mil; 66 lead; Thin Small Outline Package) Detail A 11.76 0.20 10.16 . 0.13 22.22 0.10 Lead #1 Seating Plane 0.10 0.65 Basic 0.30 + 0.03 - 0.08 0.71REF 1.20 Max Detail A 0.25 Basic Gage Plane 0.5 0.1 0.05 Min REV 1.1 Jun 29, 2005 75 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. N2DS25640CT / N2DS25680CT / N2DS25616CT N2DS25640CS / N2DS25680CS / N2DS25616CS 256Mb DDR SDRAM Revision Log Rev Date Modification 0.1 12/2003 Preliminary Release. 0.2 02/2004 Added Idd values for 5 and 6K speed grade. 0.3 April 1, 2004 Added updated IDD values. 0.4 May 7, 2004 Updated timing parameters for 5 and 6K speed grades. 0.5 Sep 15, 2004 Added lead & halogen free part numbers to spec. 1.0 Jun 22, 2005 Added AC timing for 75B speed grades. 1.1 Jun 29, 2005 Added IDD for 75B speed grades NANYA TECHNOLOGY CORPORATION HWA YA Technology Park 669, FU HSING 3rd Rd., Kueishan, Taoyuan, Taiwan, R.O.C. The NANYA TECHNOLOGY CORPORATION home page can be found at http:\\www.elixir-memory.com REV 1.1 Jun 29, 2005 76 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice.