POMEREX Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Powerex, Europe, S.A. 428 Avenue G. Durand, BP107, 72003 Le Mans, France (43) 41.14.14 C180__ X500 Phase Control SCR 190 Amperes Average 600 Volts K DIA. HOLE H DIA, HOLE~_ r ~ CATHODE POTENTIAL RED = GATE WHITE E DIA. ~ MARKING 1.245 7 31.62 MM ' A ' ACROSS FLATS [ +- .750-16 UNF - 2A THD. ! CASE NUMBER T60 STRIKE DISTANCE = .65 INCH / 16.5 MM MIN. NOMINAL DIMENSIONS CREEPAGE DISTANCE = 65 INCH / 16.5 MM MIN. SYM. A B c [ 6b E FT 6 H 3 [kK INCHES || 1.06 55 450 [225 [ 07 [797 | 63 2e1 | 7.91 | 146 MM 26.9 | 14.0 | 38.1 [57.2 [27.2 [200.9 | 6.0 [7.14 | 2009 | a7 | ALL DIMENSIONS ARE REFERENCE C180__X500 (Outline Drawing) Ordering Information: Select the complete nine digit part number you desire from the table, i.e. C180MX500 is a 600 Volt, 190 Ampere Phase Contro! SCR. Voltage Current Vonm Type VARM Code | '(ay) C180__X500 | 100 A | 190 200 B 300 c 400 D 500 E 600 M C180__X500 Phase Control SCR 190 Amperes Average, 600 Volts Description: Powerex Silicon Controlled Rectifiers (SCR) are designed for phase control applications. These are all-diffused, compression bonded encapsulated (CBE) devices employing the field-proven amplifying (di/namic) gate. Features: Low On-State Voltage High di/dt High dv/dt Hermetic Packaging OOO00 Excellent Surge and |2t Ratings Applications: ] Power Supplies [] Battery Chargers [] Motor Control P-43POWEREX Powerex, inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Powerex, Europe, S.A. 428 Avenue G. Durand, BP107, 72003 Le Mans, France (43) 41.14.14 c180__X500 Phase Control SCR 190 Amperes Average, 600 Volts Absolute Maximum Ratings Symbei C180__X500 Units RMS On-State Current @ Tc = 92C _hews, 300 Amperes Average On-State Current @ Tc = 92C bray 190 Amperes Peak One-Cycle Surge (Non Repetitive) On-State Current (60Hz) Irsaa 5500 Amperes Peak One-Cycle Surge (Non-Repetitive) On-State Current (50H2) Its 5000 Amperes Critical Rate-of-Rise of On-State Current (Non-Repetitive) di/dt 800 Amperes/ps Critical Rate-of-Rise of On-State Current (Repetitive) di/dt 150 Amperes/ ps lt (for Fusing), 8.3 milliseconds Pt 125,000 Asec Peak Gate Power Dissipation Pom 10 Watts Average Gate Power Dissipation Poway 2 Watts Storage Temperature Tste 40 to 150 C Operating Temperature Ty 40 to 125 C Mounting Torque 250 to 300 in.-Ib. Mounting Torque 28 to 34 N-M Electrical and Thermal Characteristics Characteristics Symbol Test Conditions c180__x5a0 Units VoltageBlocking State Maximums Forward Leakage, Peak loam T, = 125C, Voaw = Rated 20 mA Reverse Leakage,.Peak Ihr T, = 125C, Vanw = Rated 20 mA CurrentConducting State Maximums Peak On-State Voltage Vim T, = 25C, ly = 900A Peak 1.75 Volts Switching Typical Turn-Off Time ty I; = 150A, T) = 125C, dip/dt = 12.5A/psec 100 psec Reapplied dv/dt = 20V/jsec, Linear to 0.8 Voam Va = 50V Typical Delay Time ty ly = 100A, Voam = rated; 1.0 psec . Gate supply: 10V, open circuit; AR, = 250, 0.1psec rise time Min. Critical dv/dt exponential to Vorm dv/dt T, = 125C, Gate Open 200 V/psec Thermal : Maximum Thermal Resistance Junction to Case Rasc 0.14 *C/Watt Case to Sink, Lubricated Recs 0.075 *C/Watt GateMaximum Parameters Gate Current to Trigger ler T. = 25C; Vp = 6Vde, R_ = 30 150 mA Gate Voltage to Trigger Ver Te = 40C to 125C, Vp = 6Vdeo, R_ = 32 3.0 Volts Non-Triggering Gate Voltage Voom T, = 125C, Rated Vorm, Ai. = 10000 0.15 Volts Peak Forward Gate Current lotw 10 Amperes Peak Reverse Gaie Voltage Vorm 5 Volts P-44POWEREX Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697- 1800 (412) 925-7272 Powerex, Europe, S.A. 428 Avenue G. Durand, BP107, 72003 Le Mans, France (43) 41.14.14 C180__ X500 Phase Control SCR 190 Amperes Average, 600 Volts MAXIMUM ON-STATE CHARACTERISTICS ny RN > @ oOo tlm + NY Oo INSTANTANEOUS ON-STATE VOLTAGE, Vn, (VOLTS) oO 10! 102 108 104 INSTANTANEOUS ON-STATE CURRENT, In, (AMPERES) MAXIMUM ALLOWABLE CASE TEMPERATURE (SINUSOIDAL WAVEFORM) MAXIMUM ALLOWABLE CASE TEMPERATURE, Tc, (Cc) 200 300 400 AVERAGE ON-STATE CURRENT, lie, (AMPERES) MAXIMUM ALLOWABLE CASE TEMPERATURE (RECTANGULAR WAVEFORM) Duty Cycle= loo(t/T 80-400 MAXIMUM ALLOWABLE CASE TEMPERATURE, Tc, re) AVERAGE ON-STATE CURRENT, Ita: (AMPERES) TRANSIENT THERMAL IMPEDANCE, Zeer ((C/WATT) MAXIMUM POWER DISSIPATION, Parsi. (WATTS) MAXIMUM POWER DISSIPATION, Pavaiecy (WATTS) TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (JUNCTION TO CASE) 001 Oi 0.1 1.0 9 100 TIME, t, (SECONDS) MAXIMUM ON-STATE POWER DISSIPATION (SINUSOIDAL WAVEFORM) 1 60 9 _ 10 20 40 6080100 200 4006001000 AVERAGE ON-STATE CURRENT, hry, (AMPERES) MAXIMUM ON-STATE POWER DISSIPATION (RECTANGULAR WAVEFORM) =1 33148 ** > 1623 Percent Duty Cycle = 81/3- 10 20 40 6080100 200 4006001000 AVERAGE ON-STATE CURRENT, Iria, (AMPERES) P-45Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Powerex, Europe, S.A. 428 Avenue G. Durand, BP107, 72003 Le Mans, France (43) 41.14.14 c180__xX500 Phase Control SCR 190 Amperes Average, 600 Volts SUB-CYCLE SURGE AND It RATINGS (RATED LOAD CONDITIONS) GATE CHARACTERISTICS a ye Ft RATING, + (A RMS, > SEG x 1000 > s < INSTANTANEOUS GATE VOLTAGE, Ver, (VOLTS) HALF SINEWAVE ON-STATE PEAK CURRENT (AMPERES x 1000) I+ 1.6 4 - PULSE WIDTH, t,, (msec) INSTANTANEOUS GATE CURRENT, Isr, (AMPERES) NOTES: 1, Maximum allowable gate power dissipation = 2 watts. 2. The locus of possible DC trigger points lie outside the boundaries shown at various case temperatures. 3. Tp = rectangular gate current pulse width. P-46