CUSTOMER DRAWING
SOLDERSLEEVE SHIELD TERMINATOR WITH PRE-
INSTALLED BRAID, 200 DEG C, ROHS COMPLIANT
Unless otherwise specified dimensions are in millimeters.
[Inches dimensions are shown in brackets]
Tyco Electronics reserves the right to amend
this drawing at any time. Users should
evaluate the suitability of the product for
their application.
© 2007-2016 Tyco Electronics Corporation. All rights reserved.
If this document is printed it becomes uncontrolled. Check for the latest revision.
MATERIALS
1. INSULATION SLEEVE: Heat-shrinkable, transparent blue, radiation cross-linked modified fluoropolymer.
2. SOLDER PREFORM WITH FLUX AND THERMAL INDICATOR:
SOLDER: TYPE Sn96 per ANSI / J-STD-006.
FLUX: TYPE ROM1 per ANSI / J-STD-004.
THERMAL INDICATOR: Fusible ring with melt temp of 242C
3. MELTABLE SEALING RINGS: Environment resistant modified thermoplastic fluoropolymer. Color: light blue.
4. PRE-INSTALLED BRAID: Ni-plated copper strands per ASTM B355, Class 4. CMA= 1200
APPLICATION
1. These parts are designed to provide an environment protected shield termination on cables, rated for 150C minimum, meeting the
dimensional criteria listed, and having silver or nickel-plated shields, and insulations compatible with the insert material. For
compatible insulations consult Tyco Electronics/Raychem.
2. Install using Tyco Electronics approved convection or infrared heating tools in accordance with Tyco Electronics process standard
RCPS-100-71. When installed with approved convection or infrared heating tools, assemblies will meet the performance
requirements of SAE AS83519. Infrared tools are not recommended for use with black cable jackets.
3. Parts shall be marked with identification code per table.
4. Temperature range: -65C to +200C.
5. For best results, prepare the cable as shown: