FFD Series
FFD Series
DC Feedthrough Filters – Class Y4
231
Corcom Product Guide
Feedthrough Filters and Capacitors
5
Rated Voltage (max): 130 VDC
Rated Current: 10 to 200A
Test Voltage (two seconds): 2500 VDC
Capacitor Class (EN133200): Designed to meet Y4
Pulse Test (EN133200): 2500V Peak
Insulation Resistance (within 1 minute):
For C < 0.33F, R> 15000M
For C > 0.33F, RC(M*F)>5000s
Operating Ambient Temperature Range
(at rated current Ir):
10 to 100A: -40°C to +60°C
200A: -40°C to +50°C
Category Temperature Range: -40°C to +85°C
Current Derating Above Ambient:
10-100A: For temperature,
= R (85-)/25
200A: For temperature,
= R (85-)/35
Climatic Category: 40/85/21
MTBF: > 5 million hours typical
Insulating Materials Flammability Rating: UL94V-0
Case & Terminal Material: Nickel Plated Brass
• DC feedthrough filters
• Current ratings from 10 to 200A
• Designed to meet the very stringent safety
requirements of EN133200 class Y4 including
the 2500V pulse test
• Custom versions available
Ordering Information
10 FFD6 – CA
Filter ID
See Table
FFD Series Screw Terminals
Current Rating (in A)
Specifications
Electrical Schematic
Filter ID Value (nF)
Inductance
(nH)
DC
Resistance
(m) Max.
CA 2 x 10 70 6
HB 2 x 100 80 3
HE 2 x 100 140 8
NC 2 x 470 90 2
ND 2 x 470 120 1
NH 2 x 470 180 3
PK 2 x 1000 240 2
RP 2 x 4700 330 2
Filter Options / Specifications
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
Component Recognized by
UL to US and Canadian Requirements