MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 General Description The MAX17047/MAX17050 incorporate the Maxim ModelGaugeTM m3 algorithm that combines the excellent short-term accuracy and linearity of a coulomb counter with the excellent long-term stability of a voltage-based fuel gauge, along with temperature compensation to provide industry-leading fuel-gauge accuracy. ModelGauge m3 cancels offset accumulation error in the coulomb counter, while providing better short-term accuracy than any purely voltage-based fuel gauge. Additionally, the ModelGauge m3 algorithm does not suffer from abrupt corrections that normally occur in coulomb-counter algorithms, since tiny continual corrections are distributed over time. The device automatically compensates for aging, temperature, and discharge rate and provides accurate state of charge (SOC) in mAh or %, as well as time-to-empty over a wide range of operating conditions. The device provides two methods for reporting the age of the battery: reduction in capacity and cycle odometer. The device provides precision measurements of current, voltage, and temperature. Temperature of the battery pack is measured using an external thermistor supported by ratiometric measurements on an auxiliary input. A 2-wire (I2C) interface provides access to data and control registers. The MAX17047 is available in a lead(Pb)-free, 3mm x 3mm, 10-pin TDFN package. The MAX17050 is available in a 0.4mm pitch 9-bump WLP package. Applications Smartphones, Tablets Health and Fitness Monitors Digital Still, Video and Action Cameras Medical Devices Handheld Computers and Terminals Wireless Speakers Features Accurate Battery-Capacity and Time-To-Empty Estimation * Temperature, Age, and Rate Compensated * Does Not Require Empty, Full, or Idle States to Maintain Accuracy Precision Measurement System * No Calibration Required ModelGauge m3 Algorithm * Long-Term Influence by Voltage Fuel Gauge Cancels Coulomb-Counter Drift * Short-Term Influence by Coulomb Counter Provides Excellent Linearity * Adapts to Cell Characteristics External Temperature-Measurement Network * Actively Switched Thermistor Resistive Divider Reduces Current Consumption Low Quiescent Current * 25A Active, < 0.5A Shutdown Alert Indicator for SOC, Voltage, Temperature, and Battery Removal/Insertion Events AtRate Estimation of Remaining Capacity 2-Wire (I2C) Interface Tiny, Lead(Pb)-Free, 3mm x 3mm, 10-Pin TDFN Package or Tiny 0.4mm Pitch 9-Bump WLP Package Ordering Information appears at end of data sheet. Simple Fuel-Gauge Circuit Diagram SYSTEM BATTERY PACK PK+ VBATT THRM T PROTECTION OPTIONAL 10k NTC THERMISTOR PK- OPTIONAL 10k AIN SDA MAX17047 MAX17050 SCL REG OPTIONAL 10nF 0.1F ModelGauge is a trademark of Maxim Integrated Products, Inc. 19-6008; Rev 7; 11/16 VTT (MAX17047 ONLY) ALRT 0.1F CSP EP 10m RSNS CSN HOST P MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Absolute Maximum Ratings VBATT, SDA, SCL, ALRT to CSP.............................-0.3V to +6V REG to CSP..........................................................-0.3V to +2.2V VTT to CSP...............................................................-0.3V to +6V THRM, AIN to CSP.....................................-0.3V to (VTT + 0.3V) CSN to CSP................................................................-2V to +2V Continuous Sink Current (VTT)...........................................20mA Continuous Sink Current (SCL, SDA, ALRT)......................20mA Continuous Power Dissipation (TA = +70C) TDFN (derate 24.4mW/C above +70C)................1951.2mW WLP (derate 11.9mW/C above +70C)....................952.0mW Operating Temperature Range............................ -40C to +85C Junction Temperature.......................................................+150C Storage Temperature Range............................. -55C to +125C Lead Temperature (soldering 10s)...................................+300C Soldering Temperature (reflow)........................................+260C Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Package Thermal Characteristics (Note 1) TDFN Junction-to-Ambient Thermal Resistance (JA)...........41C/W Junction-to-Case Thermal Resistance (JC)..................9C/W WLP Junction-to-Ambient Thermal Resistance (JA)...........84C/W Note 1: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a four-layer board. For detailed information on package thermal considerations, refer to www.maximintegrated.com/thermal-tutorial. Electrical Characteristics (VBATT = 2.5V to 4.5V, TA = -20C to +70C, unless otherwise noted. Typical values are at TA = +25C.) (Note 2) PARAMETER Supply Voltage Supply Current REG Regulation Voltage Measurement Error, VBATT Measurement Resolution, VBATT VBATT Measurement Range SYMBOL VBATT IDD0 IDD1 VREG VGERR CONDITIONS (Note 3) MIN Shutdown mode, TA +50C Active mode, average current TA = +25C VLSb TYP 2.5 MAX UNITS 4.5 V 0.5 2 25 42 1.5 1.9 -7.5 +7.5 -20 +20 0.625 A V mV mV VFS 2.5 Ratiometric Measurement Accuracy, AIN TGERR -0.5 Ratiometric Measurement Resolution, AIN TLSb 0.0244 Current Register Resolution ILSb 1.5625 V 51.2 mV IOERR 1.5 Input Resistance CSN, AIN Current Full-Scale Magnitude Current Offset Error Current Gain Error Time-Base Accuracy www.maximintegrated.com 15 IFS IGERR tERR 4.98 VDD = 3.6V at TA = +25C TA = 0C to +50C TA = -20C to +70C V M +0.5 % % Full Scale V -1 +1 -1 +1 -2.5 +2.5 -3.5 +3.5 % of Reading % Maxim Integrated 2 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Electrical Characteristics (continued) (VBATT = 2.5V to 4.5V, TA = -20C to +70C, unless otherwise noted. Typical values are at TA = +25C.) (Note 2) PARAMETER SYMBOL THRM Output Drive THRM Precharge Time tPRE SDA, SCL, ALRT Input Logic High VIH SDA, SCL, ALRT Input Logic Low SDA, ALRT Output Logic Low SDA, ALRT Pulldown Current ALRT Leakage VIL VOL IPD CONDITIONS IOUT = 0.5mA MIN TYP MAX VTT - 0.1 V 8.48 ms 1.5 V 0.5 IOL = 4mA Active mode, VSDA = 0.4V, VALRT = 0.4V THRM Operating Range UNITS 0.05 0.2 2.5 V 0.4 V 0.4 A 1 A VTT V Battery-Removal Detection Threshold--VAIN Rising VDETR VTHRM - VAIN 40 125 200 mV Battery-Removal Detection Threshold--VAIN Falling VDETF VTHRM - VAIN 70 150 230 mV Battery-Removal Detection Comparator Delay tTOFF VAIN step from 70% to 100% of VTHRM to ALRT falling; Alrtp = logic 0; EnAIN = logic 1; FTHRM = logic 1 100 s RTHM = 10k NTC 100 nF MAX UNITS 400 kHz External AIN Capacitance Electrical Characteristics (2-Wire Interface) (2.5V VBATT 4.5V, TA = -20C to +70C.) (Note 2) PARAMETER SYMBOL SCL Clock Frequency fSCL Bus Free Time Between a STOP and START Condition tBUF Hold Time (Repeated) START Condition Low Period of SCL Clock tHD:STA CONDITIONS (Note 4) (Note 5) MIN 0 TYP 1.3 s 0.6 s tLOW 1.3 s tHIGH 0.6 s Setup Time for a Repeated START Condition tSU:STA 0.6 s Data Hold Time tHD:DAT High Period of SCL Clock Data Setup Time Rise Time of Both SDA and SCL Signals www.maximintegrated.com tSU:DAT tR (Notes 6, 7) (Note 6) 0 0.9 100 20 + 0.1CB s ns 300 ns Maxim Integrated 3 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Electrical Characteristics (2-Wire Interface) (continued) (2.5V VBATT 4.5V, TA = -20C to +70C.) (Note 2) PARAMETER SYMBOL CONDITIONS MIN Fall Time of Both SDA and SCL Signals tF 20 + 0.1CB Setup Time for STOP Condition tSU:STO 0.6 Spike Pulse Widths Suppressed by Input Filter tSP (Note 8) Capacitive Load for Each Bus Line CB (Note 9) SCL, SDA Input Capacitance CBIN TYP MAX UNITS 300 ns s 0 50 ns 400 pF 60 pF Note 2: Specifications are 100% tested at TA = +25C. Limits over the operating range are guaranteed by design and characterization. Note 3: All voltages are referenced to CSP. Note 4: Timing must be fast enough to prevent the device from entering shutdown mode due to bus low for a period > 45s minimum. Note 5: fSCL must meet the minimum clock low time plus the rise/fall times. Note 6: The maximum tHD:DAT has only to be met if the device does not stretch the low period (tLOW) of the SCL signal. Note 7: This device internally provides a hold time of at least 100ns for the SDA signal (referred to the minimum VIH of the SCL signal) to bridge the undefined region of the falling edge of SCL. Note 8: Filters on SDA and SCL suppress noise spikes at the input buffers and delay the sampling instant. Note 9: CB--total capacitance of one bus line in pF. I2C Bus Timing Diagram SDA tF tLOW tSU:DAT tR tSP tF tR tBUF tHD:STA SCL tHD:STA S tHD:DAT tSU:STA tSU:STO Sr P S Figure 1. I2C Bus Timing Diagram www.maximintegrated.com Maxim Integrated 4 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Typical Operating Characteristics (TA = +25C, unless otherwise noted.) 0.3 0.2 0 25 20 15 0 1 2 3 TA = -20C 10 TA = -20C 0.1 5 4 0 5 0 1 3 4 5 TA = +70C -10 -2 -1 0 1 4.0 3.8 TIME (Hr) www.maximintegrated.com 3.2 3.0 2.8 3 MAX17047 toc03 4.2 0 TA = +25C -0.4 TA = -20C -0.6 -0.8 CAPACITY (mAh); CURRENT (mA) FUEL GAUGE CHANGES TRAJECTORY AFTER TEMPERATURE CHANGE 10 TEMPERATURE 0 1 2 0 20 3.7 TA = +70C -0.2 7 3.4 SOCREP 3.2 0.2 4.2 3.6 EMPTY VOLTAGE SOCAV 2.7 0.4 8 50 30 2.2 0.6 4.4 60 40 -6 0 10 20 30 40 50 60 70 80 90 100 AIN RATIO TO VTT (%) VCELL (V) SOC (%), TEMPERATURE (C) VCELL RISES WITH TEMPERATURE DURING CONSTANT LOAD MAX17047 toc06 100 70 TA = +25C -4 0.8 -1.0 2 RESPONSE TO TEMPERATURE TRANSIENT AT CONSTANT-CURRENT LOAD 80 -2 AUXILIARY INPUT ADC ERROR vs. TEMPERATURE CURRENT FORCED (A) 90 0 VBATT (V) AUXILIARY INPUT ADC ERROR (%) MAX17047 toc04 CURRENT ADC ERROR (mA) 0 -15 2 1.0 TA = -20C TA = +25C 2 VBATT (V) 10 -50 TA = +70C 4 -10 CURRENT ADC ERROR vs. TEMPERATURE 5 TA = -20C 6 -8 VBATT (V) 15 8 END OF CHARGE DETECTION FULLCAP VALID END-OF-CHARGE DETECTION EVENT 6 VCELL 5 REMCAPREP 4 2 4.5 4.3 4.1 NEAR-FULL FALSE CHARGE TERMINATION EVENTS REJECTED 3 4.7 3.9 3.7 3.5 1 3.3 0 3.1 2.6 -1 2.4 -2 2.9 CURRENT 0 2 4 6 VCELL (V) TA = +25C 0.4 TA = +25C MAX17047 toc05 0.5 30 10 VOLTAGE ADC ERROR vs. TEMPERATURE AND SUPPLY VOLTAGE MAX17047 toc07 0.6 TA = +70C VOLTAGE ADC ERROR (mV) SHUTDOWN CURRENT (uA) 0.7 ACTIVE CURRENT vs. SUPPLY VOLTAGE MAX17047 toc02 TA = +70C 35 ACTIVE CURRENT (uA) 0.8 MAX17047 toc01 SHUTDOWN CURRENT vs. SUPPLY VOLTAGE 8 2.7 TIME (Hr) Maxim Integrated 5 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Typical Operating Characteristics (continued) (TA = +25C, unless otherwise noted.) 60 4 2 ERROR 50 80 0 70 60 -2 30 -4 20 -6 20 -8 10 -10 0 SOCREP 0 0 2 4 6 10 8 40 TIME (Hr) 90 8 80 6 SOCREP C/2 DISCHARGE 4 REFERENCE SOC 60 50 2 ERROR 0 -2 40 30 20 -6 C/7 DISCHARGE C/9 DISCHARGE 10 0 -4 C/4 DISCHARGE 0 5 10 TIME (Hr) www.maximintegrated.com -8 15 -10 ERROR (%) STATE OF CHARGE (%) 10 STATE OF CHARGE (%) OR TEMPERATURE (C) MAX17047 toc10 70 0 -2 -4 -6 SOCREP 0 2 -8 4 6 8 10 -10 TIME (Hr) CHARGE AND DISCHARGE AT +20C 100 6 2 REFERENCE SOC 30 8 4 ERROR 50 40 10 C/4 DISCHARGE C/7 DISCHARGE C/9 DISCHARGE CHARGE AND DISCHARGE IN ACTUAL SYSTEM MAX17047 toc11 100 4.2 90 4.1 80 4.0 70 50 3.8 3.7 TEMPERATURE 40 30 3.6 SOCREP (%) 20 REFERENCE SOC (%) 10 0 3.9 VCELL 60 0 5 10 VCELL (V) 70 90 6 10 ERROR (%) REFERENCE SOC 8 DISCHARGE AT +40C MAX17047 toc09 80 100 ERROR (%) STATE OF CHARGE (%) 90 10 STATE OF CHARGE (%) MAX17047 toc08 COLD DISCHARGE (0C) 100 3.5 3.4 3.3 3.2 TIME (Hr) Maxim Integrated 6 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Pin/Bump Configurations MAX17050 TOP VIEW 1 2 3 A AIN SCL CSN B VBATT ALRT REG C SDA THRM CSP + VTT 1 AIN + 10 VBATT 2 9 THRM SCL 3 8 ALRT SDA 4 7 REG CSN 5 6 CSP MAX17047 EP WLP TDFN Pin/Bump Descriptions PIN BUMP TDFN WLP 1 -- VTT Supply Input for Thermistor Bias Switch (MAX17047 Only.) VTT is connected internally to VBATT on the MAX17050. Connect to supply for ratiometric AIN pin-voltage measurements. In most applications, connect VTT to VBATT. 2 A1 AIN Auxiliary Voltage Input. Auxiliary voltage input from external thermal-measurement network. AIN also provides battery insertion/removal detection. Connect to VBATT, if not used. NAME FUNCTION 3 A2 SCL Serial Clock Input. 2-wire clock line. Input only. 4 C1 SDA Serial Data Input/Out. 2-wire data line. Open-drain output driver. 5 A3 CSN Sense Resistor Connection. System ground connection and sense resistor input. 6 C3 CSP Chip Ground and Sense Resistor Input 7 B3 REG Voltage Regulator Bypass. Connect a 0.1F capacitor from REG to CSP. 8 B2 ALRT Alert Indication. An open-drain n-channel output used to indicate specified condition thresholds have been met. A 200k pullup resistor to power rail is required for use as an output. Alternatively, ALRT can operate as a shutdown input with the output function disabled. 9 C2 THRM Thermistor Bias Connection. Supply for thermistor resistor-divider. Connect to the high side of the thermistor/resistor-divider. THRM connects internally to VTT during temperature measurement. 10 B1 VBATT Power-Supply and Battery Voltage-Sense Input. Kelvin connect to positive terminal of battery pack. Bypass with a 0.1F capacitor to CSP. -- -- EP www.maximintegrated.com Exposed Pad (TDFN Only). Connect to CSP. Maxim Integrated 7 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Block Diagram VBATT 0.1F PK- 32kHz OSCILLATOR PK+ REG VTT (MAX17047 ONLY) OCV CALCULATION OUT MAX17047 MAX17050 P VTHRM - VDETR/VDETF BATTERY REMOVAL VBATT DETECT AIN MUX 10nF CSP PK- CSP REF THRM REF ADC 12-BIT ADC SDA I 2C INTERFACE SCL CSN 10m RSNS PK- Detailed Description The MAX17047/MAX17050 incorporate the Maxim ModelGauge m3 algorithm that combines the excellent short-term accuracy and linearity of a coulomb counter with the excellent long-term stability of a voltage-based fuel gauge, along with temperature compensation to provide industry-leading fuel-gauge accuracy. ModelGauge m3 cancels offset accumulation error in the coulomb counter, while providing better short-term accuracy than any purely voltage-based fuel gauge. Additionally, the ModelGauge m3 algorithm does not suffer from abrupt corrections that normally occur in coulomb-counter algorithms, since tiny continual corrections are distributed over time. The device automatically compensates for aging, temperature, and discharge rate and provides accurate state-of-charge (SOC) in mAh or % over a wide range of operating conditions. The device provides two methods for reporting the age of the battery: reduction in capacity and cycle odometer. The device provides precision measurements of current, voltage, and temperature. Temperature of the battery www.maximintegrated.com ModelGauge m3 ALGORITHM 2V LDO PK- 0.1F ALRT IN PK+ SYSTEM GROUND pack is measured using an external thermistor supported by ratiometric measurements on an auxiliary input. A 2-wire (I2C) interface provides access to data and control registers. The MAX17047 is available in a 3mm x 3mm, 10-pin TDFN package. The MAX17050 is available in a 0.4mm pitch 9-bump WLP package. ModelGauge m3 Algorithm The ModelGauge m3 algorithm combines a high-accuracy coulomb counter with a voltage fuel gauge (VFG) as represented in Figure 2. Classical coulomb-counter-based fuel gauges have excellent linearity and short-term performance. However, they suffer from drift due to the accumulation of the offset error in the current-sense measurement. Although the offset error is often very small, it cannot be eliminated, causes the reported capacity error to increase over time, and requires periodic corrections. Corrections are usually performed at full or empty. Some other systems also use the relaxed battery voltage to perform corrections. These systems determine the SOC based on the battery voltage after a long time of no current flow. Both have the same limitation: if the correction condition is not observed over Maxim Integrated 8 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 VOLTAGE FUEL GAUGE VOLTAGE RELAXED CELL DETECTION OCV TEMPERATURECOMPENSATION LEARN OCV CALCULATION OCV OUTPUT OCV TABLE LOOKUP % REMAINING OUTPUT COULOMB COUNTER mAh OUTPUT CURRENT TIME CAPACITY LEARN mAh PER % MIXING ALGORITHM mAh OUTPUT EMPTY DETECTION CURRENT TEMPERATURE RemCapMIX SOCMIX APPLICATION EMPTY COMPENSATION APPLICATION OUTPUTS: END-OF-CHARGE DETECTION SOCREP RemCapREP SOCAV RemCapAV TTE FullCAP CELL CHEMISTRY OUTPUTS: OCV CYCLES RCELL FullCAPNom AGE Figure 2. ModelGauge m3 Overview time in the actual application, the error in the system is boundless. The performance of classic coulomb counters is dominated by the accuracy of such corrections. Classical voltage-measurement-based SOC estimation has poor accuracy due to inadequate cell modeling, but does not accumulate offset error over time. The device includes an advanced VFG, which estimates open-circuit voltage (OCV), even during current flow, and simulates the nonlinear internal dynamics of a lithium-ion (Li+) battery to determine the SOC with improved accuracy. The model considers the time effects of a battery caused by the chemical reactions and impedance in the battery to determine SOC based on table lookup. This SOC estimation does not accumulate offset error over time. The ModelGauge m3 algorithm combines a high-accuracy coulomb counter with a VFG. The complementary www.maximintegrated.com combined result eliminates the weaknesses of both the coulomb counter and the VFG, while providing the strengths of both. A mixing algorithm combines the VFG capacity with the coulomb counter and weighs each result so that both are used optimally to determine the battery state. In this way, the VFG capacity result is used to continuously make small adjustments to the battery state, canceling the coulomb-counter drift. The ModelGauge m3 algorithm uses this battery state information and accounts for temperature, battery current, age, and application parameters to determine the remaining capacity available to the system. The ModelGauge m3 algorithm continually adapts to the cell and application through independent learning routines. As the cell ages, its change in capacity is monitored and updated and the VFG dynamics adapt based on cellvoltage behavior in the application. Maxim Integrated 9 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 OCV Estimation and Coulomb-Count Mixing The resulting output from the mixing algorithm does not suffer drift from current measurement offset error and is more stable than a stand-alone OCV estimation algorithm; see Figure 4. Initial accuracy depends on the relaxation state of the cell. The highest initial accuracy is achieved with a fully relaxed cell. The core of the ModelGauge m3 algorithm is a mixing algorithm that combines the OCV state estimation with the coulomb counter. After power-on reset of the IC, coulomb-count accuracy is unknown. The OCV state estimation is weighted heavily compared to the coulombcount output. As the cell progresses through cycles in the application, coulomb-counter accuracy improves and the mixing algorithm alters the weighting so that the coulombcounter result is dominant. From this point forward, the IC switches to servo mixing. Servo mixing provides a fixed magnitude continuous error correction to the coulomb count, up or down, based on the direction of error from the OCV estimation. This allows differences between the coulomb count and OCV estimation to be corrected quickly. See Figure 3. Fuel-Gauge Empty Compensation As the temperature and discharge rate of an application changes, the amount of charge available to the application also changes. The ModelGauge m3 algorithm distinguishes between remaining capacity of the cell (RemCapMIX) and remaining capacity of the application (RemCapAV) and reports both results to the user. Fuel-Gauge Learning and Age Support The device periodically makes internal adjustments to cell characterization and application information to remove initial error and maintain accuracy as the cell ages. These adjustments always occur as small undercorrections to prevent instability of the system and prevent any noticeable jumps in the fuel-gauge outputs. Learning occurs automatically without any input from the host. To maintain learned accuracy through power loss, the host must periodically save learned information and then restore after power is returned. See the Power-Up and Power-On Reset section for details: OCV AND COULOMB-COUNT MIXING RATIO 100% 0% COULOMB-COUNT INFLUENCE SERVO MIXING * OCV INFLUENCE 0 0.50 1.00 1.50 2.00 CELL CYCLES Full Capacity Available to Application (FullCAP). This is the total capacity available to the application at full. FullCAP is updated near the end of charging when termination is detected. See the End-of-Charge Detection section. Figure 3. ModelGauge m3 OCV and Coulomb-Count Mixing TYPICAL OCV ESTIMATION ERROR AS CELL IS CYCLED STATE-OF-CHARGE ERROR MAXIMUM COULOMB-COUNTER ERROR (SHADED AREA) ModelGauge m3 OCV + COULOMB-COUNT MIXING MAXIMUM ERROR RANGE TIME Figure 4. ModelGauge m3 Algorithm Mixing Conceptual Illustration www.maximintegrated.com Maxim Integrated 10 MAX17047/MAX17050 * * * Cell Capacity (FullCapNom). This is the total cell capacity at full, according to the VFG. This includes some capacity that is not available to the application at high loads and/or low temperature. The device periodically compares percent change based on OCV measurement vs. coulomb-count change as the cell charges and discharges. This information allows the device to maintain an accurate estimation of the cell's capacity in mAh as the cell ages. Voltage Fuel-Gauge Adaptation. The device observes the battery's relaxation response and adjusts the dynamics of the VFG. This adaptation adjusts the RCOMP0 register during qualified cell relaxation events. Empty Learning. The device updates internal data whenever cell empty is detected (VCELL < V_empty) to account for cell age or other cell deviations from the characterization information. This maintains SOC accuracy as the battery ages. Determining Fuel-Gauge Accuracy To determine the true accuracy of a fuel gauge, as experienced by end users, the battery should be exercised in a dynamic manner. The end-user accuracy cannot be understood with only simple cycles. To challenge a correction-based fuel gauge, such as a coulomb counter, test the battery with partial loading sessions. For example, a typical user may operate the device for 10min and then stop use for an hour or more. A robust test method includes these kinds of sessions many times at various loads, temperatures, and duration. Refer to Application Note 4799: Cell Characterization Procedure for a ModelGauge m3 Fuel Gauge. Initial Accuracy The device uses the first voltage reading after power-up or after cell insertion to determine the starting output of the fuel gauge. It is assumed that the cell is fully relaxed prior to this reading; however, this is not always the case. If the cell was recently charged or discharged, the voltage measured by the device may not represent the true state of charge of the cell, resulting in initial error in the fuel gauge outputs. In most cases, this error is minor and is quickly removed by the fuel gauge algorithm during normal operation. www.maximintegrated.com 1-Cell Fuel Gauge with ModelGauge m3 Typical Operating Circuit The device is designed to mount outside the cell pack that it monitors. Voltage of the battery pack is measured directly at the pack terminals by the VBATT and CSP connections. Current is measured by an external sense resistor placed between the CSP and CSN pins. An external resistor-divider network allows the device to measure temperature of the cell pack by monitoring the AIN pin. The THRM pin provides a strong pullup for the resistordivider that is internally disabled when temperature is not being measured. Communication to the host occurs over a standard I2C interface. SCL is an input from the host, and SDA is an open-drain I/O pin that requires an external pullup. The ALRT pin is an output that can be used as an external interrupt to the host processor if certain application conditions are detected. ALRT can also function as an input, allowing the host to shut down the device. This pin is also open drain and requires an external pullup resistor. Figure 5 is the typical operating circuit. Multicell Circuit The MAX17047 can be used in multicell pack applications. A resistor-divider network divides the pack voltage down so that the IC monitors the equivalent voltage of a single cell. The MAX9910 buffers the divider output so that loading by the MAX17047 does not affect accuracy. VTT must be connected to a regulated supply in the system to prevent overloading the MAX9910. Contact the factory for a MAX17050 multicell application circuit. See Figure 6. Thermistor Sharing Circuit The MAX17047 can share the cell thermistor circuit with the system charger. In this circuit, there is a single thermistor inside the cell pack and a single bias resistor external to the cell pack. The device shares the same external bias as the charger circuit and measurement point on the thermistor. In this configuration, each device can measure temperature individually or simultaneously without interference. Alternatively, if the bias voltage in the charger circuit is not available to the device, a separate bias voltage on the VTT pin can be used. For proper operation, the separate bias voltage must be larger than the minimum operating voltage of the device, but no larger than one diode drop above the charger circuit bias voltage. The MAX17050 cannot be operated in his configuration. See Figure 7. Maxim Integrated 11 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 SYSTEM BATTERY PACK PK+ VBATT VTT (MAX17047 ONLY) OPTIONAL 200k ALRT THRM THERMISTOR MEASUREMENT OPTIONAL OPTIONAL 10k SDA MAX17047 MAX17050 AIN T OPTIONAL 5k HOST P SCL REG OPTIONAL 10k NTC THERMISTOR PROTECTION IC OPTIONAL 10nF 0.1F CSP 0.1F EP CSN 10m RSNS PK- Figure 5. Typical Operating Circuit BATTERY PACK SYSTEM PK+ CELL N 4.5V-5.5V REGULATOR N-1 M CELL 1 PROTECTOR MAX9910 1M 100 PK- 3.3nF 47k THRM 0.1F PK- HOST P SDA MAX17047 OPTIONAL 10k SCL AIN OPTIONAL 10nF PK- OPTIONAL 5k ALRT VBATT T OPTIONAL 10k NTC THERMISTOR OPTIONAL 200k VTT VB CSP 0.1F EP CSN 10m SYSTEM GROUND Figure 6. Multicell Application Circuit www.maximintegrated.com Maxim Integrated 12 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Recommended Layout Proper circuit layout (see Figure 8) is essential for measurement accuracy when using the MAX17047/ MAX17050 ModelGauge m3 ICs. The recommended layout guidelines are as follows: 1) Mount RSNS as close as possible to PACK-. The device shares both voltage and current measurements on the CSP pin. Therefore, it is important to limit the amount of trace resistance between the current-sensing resistor and PACK-. 2) VBATT trace should make a Kelvin connection to PACK+. The device shares the VBATT pin for both voltage measurement and IC power. Limiting the voltage loss through this trace is important to voltagemeasurement accuracy. PCB resistance that cannot be removed can be compensated for during characterization of the application cell. 3) CSN and CSP traces should make Kelvin connections to RSNS. The device measures current differentially through the CSN and CSP pins. Any shared high-current paths on these traces will affect currentmeasurement gain accuracy. PCB resistance that cannot be removed can be compensated for during characterization of the application cell. 4) VBATT capacitor trace loop area should be minimized. The device shares the VBATT pin for both voltage measurement and IC power. Limiting noise at the VBATT pin is important to current-measurement accuracy. 5) REG capacitor trace loop area should be minimized. The helps filter any noise from the internal regulated supply. 6) There are no limitations on any other IC connection. Connections to THRM, ALRT, SDA, SCL, VTT, and AIN, as well as any external components mounted to these pins, have no special layout requirements. VBIAS 2.8V < VBIAS < VINTERNAL + 0.6V CHARGER WITH VTT + THRM AVAILABLE P CHARGER WITH INTERNAL BIAS MAX17047 VBIAS MAX17047 VTT VOLTAGE BASED ON EXISTING CHARGER REQUIREMENTS VTT VBATT P THRM AIN THERMISTOR INSIDE CELL PACK VSYSTEM VINTERNAL ON DURING CHARGE OFF DURING DISCHARGE AIN THERMISTOR INSIDE CELL PACK PK- VSYSTEM THRM CSP MAX17047 + CHARGER WITH EXTERNAL BIAS VBATT P CSP MAX17047 + CHARGER WITH INTERNAL BIAS PK- Figure 7. Operating Circuits that Share Pack Thermistor with System Charger www.maximintegrated.com Maxim Integrated 13 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 POSITIVE POWER BUS POSITIVE POWER BUS PACK+ VBATT VTT AIN SCL THRM MAX17047 SDA CSN PACK+ EP CVBATT ALRT REG SDA VBATT AIN THRM ALRT SCL CSP REG CSN + CVBATT CREG REG MAX17050 CSP CREG NEGATIVE POWER BUS NEGATIVE POWER BUS RSNS PACK- PACK- RSNS Figure 8. Proper Board Layout ModelGauge m3 Registers To calculate accurate results, ModelGauge m3 requires information about the cell, the application, and real-time information measured by the device. Figure 9 shows all inputs and outputs to the algorithm grouped by category. Analog input registers are the real-time measurements of voltage, temperature, and current performed by the device. Application-specific registers are programmed by the customer to reflect the operation of the application. The Cell Characterization Information registers hold characterization data that models the behavior of the cell over the operating range of the application. The Algorithm Configuration registers allow the host to adjust performance of the device for its application. The Save and Restore registers allow an application to maintain accuracy of the algorithm after the device has been power cycled. The following sections describe each register in detail. www.maximintegrated.com ModelGauge Algorithm Output Registers The following registers hold the output results from the ModelGauge m3 algorithm. SOCMIX Register (0Dh) The SOCMIX register holds the calculated present state of charge of the cell before any empty compensation adjustments are performed. The register value is stored as a percentage with a resolution of 0.0039% per LSb. If an 8-bit state-of-charge value is desired, the host can discard the lower byte and use only the upper byte of the register with a resolution of 1.0%. Figure 10 shows the SOCMIX register format. Maxim Integrated 14 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 VCELL SOCMIX CURRENT RemCapMIX TEMPERATURE SOCREP AverageVCELL RemCapREP AverageCurrent SOCAV AverageTemperature RemCapAV ANALOG INPUTS DesignCap AGE ICHGTerm APPLICATION SPECIFIC CYCLES FullSOCThr OCV V_empty FullCAP ModelGauge ALGORITHM FullCapNom CHARACTERIZATION TABLE FSTAT QResidual Table FullCAP FCTC CELL CHARACTERIZATION INFORMATION ModelGauge ALGORITHM OUTPUTS TTE RCOMP0 LearnCFG CYCLES TempCo FilterCFG QResidual Table TempNom RelaxCFG TempLim MiscCFG V_empty AtRate ALGORITHM CONFIGURATION RCOMP0 TempCo SAVE AND RESTORE INFORMATION dQacc dPacc FullCapNom Iavg_empty Figure 9. ModelGauge m3 Register Map MSB--ADDRESS 0Dh 27 26 25 24 23 22 MSb LSB--ADDRESS 0Dh 21 20 2-1 LSb MSb 2-2 2-3 2-4 2-5 2-6 2-7 2-8 LSb 2-8 UNITS: 0.0039% 20 UNITS: 1.0% Figure 10. SOCMIX Register Format (Output) www.maximintegrated.com Maxim Integrated 15 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 RemCapMIX Register (0Fh) The RemCapMIX register holds the calculated remaining capacity of the cell before any empty compensation adjustments are performed. The value is stored in terms of Vh and must be divided by the application sense-resistor value to determine remaining capacity in mAh. Figure 11 shows the RemCapMIX register format. SOCREP Register (06h) SOCREP is a filtered version of the SOCAV register that prevents large jumps in the reported value caused by changes in the application such as abrupt changes in load current. The register value is stored as a percentage with a resolution of 0.0039% per LSb. If an 8-bit SOC value is desired, the host can discard the lower byte and use only the upper byte of the register with a resolution of 1.0%. Figure 12 shows the SOCREP register format. RemCapREP Register (05h) RemCapREP is a filtered version of the RemCapAV register that prevents large jumps in the reported value caused by changes in the application such as abrupt changes in load current. The value is stored in terms of Vh and must be divided by the application sense-resistor value to determine remaining capacity in mAh. During application idle periods where the AverageCurrent Register value is less than 6 LSbs, RemCapREP does not change. The measured current during this period is still accumulated into RemCapMIX and is slowly reflected in RemCapREP once cell loading or charging occurs. Figure 13 shows the RemCapREP register format. MSB--ADDRESS 0Fh 215 214 213 212 211 210 LSB--ADDRESS 0Fh 29 MSb 28 27 LSb MSb 26 25 24 23 22 21 20 LSb 20 UNITS: 5.0Vh/RSENSE (0.5mAh WHEN RSENSE = 0.010) Figure 11. RemCapMIX Register Format (Output) MSB--ADDRESS 06h 27 26 25 24 23 22 LSB--ADDRESS 06h 21 MSb 20 2-1 LSb MSb 2-2 2-3 2-4 2-5 2-6 2-7 2-8 LSb 2-8 UNITS: 0.0039% 20 UNITS: 1.0% Figure 12. SOCREP Register Format (Output) MSB--ADDRESS 05h 215 214 213 212 211 210 MSb LSB--ADDRESS 05h 29 28 27 LSb MSb 26 25 24 23 22 21 20 LSb 20 UNITS: 5.0Vh/RSENSE (0.5mAh WHEN RSENSE = 0.010) Figure 13. RemCapREP Register Format (Output) www.maximintegrated.com Maxim Integrated 16 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 SOCAV Register (0Eh) The SOCAV register holds the calculated present state of charge of the cell based on all inputs from the ModelGauge m3 algorithm including empty compensation. The register value is stored as a percentage with a resolution of 0.0039% per LSb. If an 8-bit state-of-charge value is desired, the host can discard the lower byte and use only the upper byte of the register with a resolution of 1.0%. The SOCAV register value is an unfiltered calculation. Jumps in the value can be caused by changes in the application such as abrupt changes in load current. Figure 14 shows the SOCAV register format. RemCapAV Register (1Fh) The RemCapAV register holds the calculated remaining capacity of the cell based on all inputs from the ModelGauge m3 algorithm including empty compensation. The value is stored in terms of Vh and must be divided by the application sense-resistor value to determine the remaining capacity in mAh. The register value is an unfiltered calculation. Jumps in the value can be caused by changes in the application such as abrupt changes in load current. Figure 15 shows the RemCapAV register format. SOCVF Register (FFh) The SOCVF register holds the calculated present SOC of the battery according to the voltage fuel gauge. The register value is stored as a percentage with a resolution of 0.0039% per LSb. If an 8-bit SOC value is desired, the host can discard the lower byte and use only the upper byte of the register with a resolution of 1.0%. Figure 16 shows the SOCVF register format. TTE Register (11h) The TTE register holds the estimated time to empty for the application under present conditions. The TTE value is determined by dividing the RemCapAV register by the AverageCurrent register. The result is stored in the TTE register with a resolution of 5.625s per LSb. MSB--ADDRESS 0Eh 27 26 25 24 23 22 LSB--ADDRESS 0Eh 21 MSb 20 2-1 LSb MSb 2-2 2-3 2-4 2-5 2-6 2-7 2-8 LSb 2-8 UNITS: 0.0039% 20 UNITS: 1.0% Figure 14. SOCAV Register Format (Output) MSB--ADDRESS 1Fh 215 214 213 212 211 210 LSB--ADDRESS 1Fh 29 MSb 28 27 LSb MSb 26 25 24 23 22 21 20 LSb 20 UNITS: 5.0Vh/RSENSE (0.5mAh WHEN RSENSE = 0.010) Figure 15. RemCapAV Register Format (Output) MSB--ADDRESS FFh 27 26 25 24 23 MSb 22 LSB--ADDRESS FFh 21 20 2-1 LSb MSb 2-2 2-3 2-4 2-5 2-6 2-7 2-8 LSb 2-8 UNITS: 0.0039% 20 UNITS: 1.0% Figure 16. SOCVF Register Format (Output) www.maximintegrated.com Maxim Integrated 17 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Alternatively, the TTE register can be used to estimate time to empty for any given current load. Whenever the AtRate register is programmed to a negative number, representing a discharge current, the TTE register displays the estimated time to empty for the application based on the AtRate register value. Figure 17 shows the TTE register format. Age Register (07h) The Age register contains a calculated percentage value of the application's present cell capacity compared to its expected capacity. The result can be used by the host to gauge the cell's health as compared to a new cell of the same type. The result is displayed as a percentage value from 0 to 256% with a 0.0039% LSb. Figure 18 shows the Age register format. The equation for the register output is: Age Register = 100% x (FullCAP Register/ DesignCap Register) Cycles Register (17h) The Cycles register accumulates total percent change in the cell during both charging and discharging. The result is stored as a total count of full charge/discharge cycles. For example, a full charge/discharge cycle results in the Cycles register incrementing by 100%. The Cycles register has a full range of 0 to 65535% with a 1% LSb. This register is reset to 0% at power-up. To maintain the lifetime cycle count of the cell, this register must be periodically saved by the host and rewritten to the device at power-up. See the Save and Restore Registers section for details. See Figure 19 for the Cycles register format. VFOCV Register (FBh) The VFOCV register contains the raw open-circuit voltage output of the voltage fuel gauge. This value is used in other internal calculations and can be read for debug purposes. The result is a 12-bit value ranging from 2.5V to 5.119V where 1 LSb is 1.25mV. The bottom 4 bits of this register are don't care bits. See Figure 20 for the VFOCV register format. MSB--ADDRESS 11h 210 29 28 27 26 25 LSB--ADDRESS 11h 24 MSb 23 22 LSb MSb 21 20 2-1 2-2 2-3 2-4 2-5 LSb 20 UNITS: 3.0min Figure 17. TTE Register Format (Output) MSB--ADDRESS 07h 27 26 25 24 23 22 LSB--ADDRESS 07h 21 MSb 20 2-1 LSb MSb 2-2 2-3 2-4 2-5 2-6 2-7 2-8 LSb 20 UNITS: 1.0% 2-8 UNITS: 0.0039% Figure 18. Age Register Format (Output) MSB--ADDRESS 17h 215 214 213 212 211 MSb 210 LSB--ADDRESS 17h 29 28 27 LSb MSb 26 25 24 23 22 21 20 LSb 20 UNITS: 1.0% Figure 19. Cycles Register Format (Output) www.maximintegrated.com Maxim Integrated 18 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 FullCAP Register (10h) This register holds the ModelGauge m3 algorithm calculated full capacity of the cell under best-case conditions (light load, hot). A new full-capacity value is calculated after the end of every charge cycle in the application. The value is stored in terms of Vh and must be divided by the application sense-resistor value to determine capacity in mAh. Figure 21 is the FullCAP register format. See the End-of-Charge Detection section. FullCapNom Register (23h) This register holds the calculated full capacity of the cell, not including temperature and charger tolerance. New full capacity values are calculated periodically by the IC during operation. The value is stored in terms of Vh and must be divided by the application sense resistor value to determine capacity in mAh. This register is used to calculate the outputs of the ModelGauge m3 algorithm and is available to the user only for debug. Figure 22 is the FullCapNom register format. MSB--ADDRESS FBh 211 210 29 28 27 26 LSB--ADDRESS FBh 25 MSb 24 23 LSb MSb 22 21 20 X X X X LSb 20 UNITS: 1.25mV X = DON'T CARE Figure 20. VFOCV Register Format (Output) MSB--ADDRESS 10h 215 214 213 212 211 210 LSB--ADDRESS 10h 29 MSb 28 27 LSb MSb 26 25 24 23 22 21 20 LSb 20 UNITS: 5.0Vh/RSENSE (0.5mAh WHEN RSENSE = 0.010) Figure 21. FullCAP Register Format (Output) MSB--ADDRESS 23h 215 214 213 212 211 210 MSb LSB--ADDRESS 23h 29 28 27 LSb MSb 26 25 24 23 22 21 20 LSb 20 UNITS: 5.0Vh/RSENSE (0.5mAh WHEN RSENSE = 0.010) Figure 22. FullCapNom Register Format (Output) www.maximintegrated.com Maxim Integrated 19 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 QH Register (4Dh) The QH register displays the raw coulomb count generated by the device. This register is used internally as an input to the mixing algorithm. Monitoring changes in QH over time can be useful for debugging device operation. The QH register is set to 0000h at power-up. The QH register format is shown in Figure 23. of the cell by comparing against the calculated present capacity stored in the FullCAP register. DesignCap has an LSb equal to 5.0Vh and a full range of 0 to 327.68mVh. The user should multiply the mAh capacity of the cell by the sense resistor value to determine the Vh value to store in the DesignCap register. The DesignCap register format is shown in Figure 24. FullSOCThr Register (13h) Application-Specific Registers The following registers define the behavior of the application. They must be programmed by the user before the ModelGauge m3 algorithm is accurate. Any changes to these register values require recharacterization of the cell. DesignCap Register (18h) The DesignCap register holds the expected capacity of the cell. This value is used to determine age and health The FullSOCThr register gates detection of end-of-charge. SOCVF must be larger than the FullSOCThr value before ICHGTerm is compared to the AverageCurrent register value. The recommended FullSOCThr register setting for most applications is 95%. See the ICHGTerm register description for details. The FullSOCThr register is 70% at power-up. Figure 25 is the FullSOCThr register format. MSB--Address 4Dh 215 214 213 212 211 210 LSB--ADDRESS 4Dh 29 MSb 28 27 LSb MSb 26 25 24 23 22 21 20 LSb 20 UNITS: 5.0Vh/RSENSE (0.5mAh WHEN RSENSE = 0.010) Figure 23. QH Register Format (Output) MSB--ADDRESS 18h 215 214 213 212 211 210 LSB--ADDRESS 18h 29 MSb 28 27 LSb MSb 26 25 24 23 22 21 20 LSb 20 UNITS: 5.0Vh/RSENSE (0.5mAh WHEN RSENSE = 0.010) Figure 24. DesignCap Register Format (Input) MSB--ADDRESS 18h 27 26 25 24 23 22 MSb LSB--ADDRESS 18h 21 20 2-1 LSb MSb 2-2 2-3 2-4 2-5 2-6 2-7 2-8 LSb 2-8 UNITS: 0.0039% 20 UNITS: 1.0% Figure 25. FullSOCThr Register Format (Input) www.maximintegrated.com Maxim Integrated 20 MAX17047/MAX17050 End-of-Charge Detection 1-Cell Fuel Gauge with ModelGauge m3 The device detects the end of a charge cycle when the application current falls into the band set by the ICHGTerm register value. By monitoring both the Current and AverageCurrent registers, the device can reject false end-of-charge events such as application load spikes or early charge-source removal. See the End-of-Charge Detection graph in the Typical Operating Characteristics and Figure 26. AVERAGE CURRENT CURRENT CHARGING 1.25 x ICHGTerm 0.125 x ICHGTerm 0mA HIGH-CURRENT LOAD SPIKES DO NOT GENERATE END-OF-CHARGE DETECTION BECAUSE CURRENT AND AVERAGE CURRENT READINGS DO NOT FALL INTO THE DETECTION AREA AT THE SAME TIME. DISCHARGING AVERAGE CURRENT CURRENT CHARGING 1.25 x ICHGTerm 0.125 x ICHGTerm 0mA DISCHARGING EARLY CHARGER REMOVAL DOES NOT GENERATE END-OF-CHARGE DETECTION BECAUSE CURRENT AND AVERAGE CURRENT READINGS DO NOT FALL INTO THE DETECTION AREA AT THE SAME TIME. Figure 26. False End-of-Charge Events www.maximintegrated.com Maxim Integrated 21 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 When a proper end-of-charge event is detected, the device learns a new FullCAP register value based on the RemCapREP output. If the old FullCAP value was too high, it is adjusted downward after the last valid endof-charge detection. If the old FullCAP was too low, it is adjusted upward to match RemCapREP. This prevents the calculated state of charge from ever reporting a value greater than 100%. See Figure 27. ICHGTerm Register (1Eh) The ICHGTerm register allows the device to detect when a charge cycle of the cell has completed. The host should set the ICHGTerm register value equal to the exact charge termination current used in the application. The device detects end of charge if all the following conditions are met: * SOCVF > FullSOCThr * AND ICHGTerm x 0.125 < Current < ICHGTerm x 1.25 * AND ICHGTerm x 0.125 < AverageCurrent < ICHGTerm x 1.25 Values are stored in V. Multiply the termination current by the sense resistor to determine the desired register value. This register has the same range and resolution as the Current register. Figure 28 shows the ICHGTerm register format. ICHGTerm defaults to 150mA (03C0h) at power-up. AVERAGE CURRENT CURRENT CHARGING 1.25 x ICHGTerm 0.125 x ICHGTerm 0mA HIGH-CURRENT LOAD SPIKES DO NOT GENERATE END-OF-CHARGE DETECTION BECAUSE CURRENT AND AVERAGE CURRENT READINGS DO NOT FALL INTO THE DETECTION AREA AT THE SAME. TIME DISCHARGING AVERAGE CURRENT CURRENT CHARGING 1.25 x ICHGTerm 0.125 x ICHGTerm 0mA DISCHARGING EARLY CHARGER REMOVAL DOES NOT GENERATE END-OF-CHARGE DETECTION BECAUSE CURRENT AND AVERAGE CURRENT READINGS DO NOT FALL INTO THE DETECTION AREA AT THE SAME TIME. Figure 27. FullCAP Learning at End of Charge www.maximintegrated.com Maxim Integrated 22 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 V_empty Register (3Ah) The V_empty register sets thresholds related to empty detection during operation. Figure 29 is the V_empty register format. VE8:VE0--Empty Voltage. Sets the voltage level for detecting empty. A 10mV resolution gives a 0 to 5.11V range. This value is written to 3.12V at power-up. Table 1. Cell Characterization Information Registers REGISTER ADDRESS Characterization Table (48 words) 80h to AFh FullCap 10h VR6:VR0--Recovery Voltage. Sets the voltage level for clearing empty detection. Once the cell voltage rises above this point, empty voltage detection is reenabled. A 40mV resolution gives a 0 to 5.08V range. This value is written to 3.68V at power-up. Cell Characterization Information Registers Proper cell characterization is required to achieve accuracy. The following registers (Table 1) hold information that must be generated through a cell-characterization procedure. Maxim provides a cell-characterization service. Contact the factory for details. DesignCap 18h ICHGTerm 1Eh FullCapNom 23h RCOMP0 38h lavg_empty 36h TempCo 39h QResidual 00 12h QResidual 10 22h QResidual 20 32h QResidual 30 42h MSB--ADDRESS 1Eh S 214 213 212 211 210 LSB--ADDRESS 1Eh 29 MSb 28 27 LSb MSb 26 25 24 23 22 21 20 LSb UNITS: 1.5625V/RSENSE Figure 28. ICHGTerm Register Format (Input) MSB--ADDRESS 3Ah VE8 VE8 VE6 VE5 VE4 VE3 MSb LSB--ADDRESS 3Ah VE2 VE1 VE0 LSb MSb VR6 VR5 VR4 VR3 VR2 VR1 VR0 LSb VR0 UNITS: 40mV VE0 UNITS: 10mV Figure 29. V_empty Register Format (Input) www.maximintegrated.com Maxim Integrated 23 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Mixing Period = 175.8ms x 2(5+MIX) Algorithm Configuration Registers TEMP2:TEMP0--Sets the time constant for the AverageTemperature register. The default POR value of 1h gives a time constant of 12min. The equation setting the period is: The following registers allow operation of the ModelGauge m3 algorithm to be adjusted for the application. It is recommended that the default values for these registers be used. FilterCFG Register (29h) AvergeTemperature time constant = 175.8ms x 2(8 + TEMP) The FilterCFG register sets the averaging time period for all A/D readings, for mixing OCV results and coulombcount results. It is recommended that these values are not changed unless absolutely required by the application. Figure 30 shows the FilterCFG register format: X--Reserved. Do not modify. RelaxCFG Register (2Ah) The RelaxCFG register defines how the device detects if the cell is in a relaxed state. See Figure 32. For a cell to be considered relaxed, current flow through the cell must be kept at a minimum while the change in the cell's voltage over time, dV/dt, shows little or no change. If AverageCurrent remains below the Load threshold while VCELL changes less than the dV threshold over two consecutive periods of dt, the cell is considered relaxed. Figure 31 shows the RelaxCFG register format: CURR3:CURR0--Sets the time constant for the AverageCurrent register. The default POR value of 4h gives a time constant of 11.25 seconds. The equation setting the period is: AverageCurrent time constant = 175.8ms x 2(2+CURR) VOLT2:VOLT0--Sets the time constant for the AverageVCELL register. The default POR value of 2h gives a time constant of 45.0s. The equation setting the period is: Load6:Load0--Sets the threshold, which the AverageCurrent register is compared against. The AverageCurrent register must remain below this threshold value for the cell to be considered unloaded. Load is an unsigned 7-bit value where 1 LSb = 50V. The default value is 800V. AverageVCELL time constant = 175.8ms x 2(6+VOLT) MIX3:MIX0--Sets the time constant for the mixing algorithm. The default POR value of Dh gives a time constant of 12.8 hours. The equation setting the period is: MSB--ADDRESS 29h X X LSB--ADDRESS 29h TEMP TEMP TEMP MIX3 MIX2 MIX1 2 1 0 MSb LSb MIX0 VOLT2 VOLT1 VOLT0 CURR CURR CURR CURR 3 2 1 0 MSb LSb Figure 30. FilterCFG Register Format (Input) MSB--ADDRESS 2Ah LSB--ADDRESS 2Ah Load6 Load5 Load4 Load3 Load2 Load1 Load0 dV4 dV3 MSb LSb MSb dV2 dV1 dV0 dt3 dt2 dt1 dt0 LSb LOAD0 UNITS: 50V/RSENSE (5.0mAh WHEN RSENSE = 0.010) Figure 31. RelaxCFG Register Format (Input) www.maximintegrated.com Maxim Integrated 24 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 dV4:dV0--Sets the threshold, which VCELL is compared against. If the cell's voltage changes by less than dV over two consecutive periods set by dt, the cell is considered relaxed; dV has a range of 0 to 40mV where 1 LSb = 1.25mV. The default value is 1.75mV. dt3:dt0--Sets the time period over which change in VCELL is compared against dV. If the cell's voltage changes by less than dV over two consecutive periods set by dt, the cell is considered relaxed. The default value is 6 minutes. The comparison period is calculated as: Relaxation Period = 2dt x 0.1758s LearnCFG Register (28h) The LearnCFG register controls all functions relating to adaptation during operation. The LearnCFG register default values should not be changed unless specifically required by the application. Figure 33 is the LearnCFG register format: 0--Bit must be written 0. Do not write 1. 1--Bit must be written 1. Do not write 0. Filt Empty--Empty Detect Filter. This bit selects whether empty is detected by a filtered or unfiltered voltage reading. Setting this bit to 1 causes the empty detection algorithm to use the AverageVCELL register. Setting this bit to 0 forces the empty detection algorithm to use the VCELL register. This bit is written to 0 at power-up. 0 RELAXATION LOAD THRESHOLD AVERAGE CURRENT DISCHARGING dV6 dV5 dV4 CELL VOLTAGE dV3 dV2 dt1 dt2 dt3 dt4 CELL UNLOADED (RELAXATION BEGINS) 48 TO 96 MINUTES dt5 dt6 FIRST READING BELOW dv/dt THRESHOLD SECOND READING BELOW dV/dt THRESHOLD LONG RELAXATION RelDt2 BIT SET CELL IS RELAXED RelDt BIT SET CELL CAPACITY IS LEARNED Figure 32. Cell Relaxation Detection MSB--ADDRESS 0 0 1 0 0 LSB--ADDRESS 1 1 MSb 0 0 LSb MSb LS2 LS1 LS0 0 Filt Empty 1 EL LSb Figure 33. LearnCFG Register Format (Input/Output) www.maximintegrated.com Maxim Integrated 25 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 LS2:LS0--Learn Stage. See Figure 3 The Learn Stage value controls the influence of the VFG on the mixing algorithm. At power-up, Learn Stage defaults to 0h, making the voltage fuel gauge dominate. Learn Stage then advances to 7h over the course of two full cell cycles to make the coulomb counter dominate. Host software can write the Learn Stage value to 7h to advance to the final stage at any time. Writing any value between 1h and 6h is ignored. Learn Stage reflects the D5, D6, and D7 bits of the Cycles register. Update the Cycles register to advance to an intermediate state. For example, set Cycles = 160% to advance to Learn Stage 5. EL--Empty Learning. Set this bit to 1 to turn on the Empty Learning feature. When enabled, the QResidual table is automatically adjusted at each empty event to compensate for the age of battery. MiscCFG Register (2Bh) The MiscCFG control register enables various other functions of the device. The MiscCFG register default values should not be changed unless specifically required by the application. Figure 34 is the MiscCFG register format: 0--Bit must be written 0. Do not write 1. 1--Bit must be written 1. Do not write 0. X--Don't Care. Bit may read 0 or 1. SACFG1:SACFG0--SOC Alert Config. SOC Alerts can be generated by monitoring any of the SOC registers as follows. SACFG defaults to 00 at power-up: 0 0 SOC Alerts are generated based on the SOCREP register. 0 1 SOC Alerts are generated based on the SOCAV register. 1 0 SOC Alerts are generated based on the SOCMIX register. 1 1 SOC Alerts are generated based on the SOCVF register. MR4:MR0--Mixing Rate. This value sets the strength of the servo mixing rate after the final mixing state has been reached (> 2.08 complete cycles). The units are MR0 = 6.25V, giving a range up to 19.375mA with a standard 0.010 sense resistor. Setting this value to 00000b disables servo mixing and the IC continues with timeconstant mixing indefinitely. The default setting is 18.75V or 1.875mA with a standard sense resistor. enBi1--Enable reset on battery-insertion detection. Set this bit to 1 to force a reset of the fuel gauge whenever a battery insertion is detected based on AIN pin monitoring. This bit is written to 1 at power-up. FSTAT Register (3Dh) The FSTAT register is a read-only register that monitors the status of the ModelGauge algorithm. Do not write to this register location. Figure 35 is the FSTAT register format: RelDt--Relaxed cell detection. This bit is set to a 1 whenever the ModelGauge m3 algorithm detects that the cell is in a fully relaxed state. This bit is cleared to 0 whenever a current greater than the Load threshold is detected. See Figure 32. MSB--ADDRESS 2Bh 0 0 X X enBi1 0 MSb LSB--ADDRESS 2Bh MR4 MR3 LSb MR2 MR1 MR0 1 0 0 SACFG SACFG 1 0 MSb LSb MR0 UNITS: 6.25V Figure 34. MiscCFG Register Format (Input) MSB--ADDRESS 3Dh X X X X X MSb X LSB--ADDRESS 3Dh RelDt EDet LSb X MSb RelDt2 X X X X X DNR LSb Figure 35. FSTAT Register Format (Output) www.maximintegrated.com Maxim Integrated 26 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 RelDt2--Long Relaxation. This bit is set to a 1 whenever the ModelGauge m3 algorithm detects that the cell has been relaxed for a period of 48 to 96 minutes or longer. This bit is cleared to 0 whenever the cell is no longer in a relaxed state. See Figure 32. DNR--Data Not Ready. This bit is set to 1 at cell insertion and remains set until the output registers have been updated. Afterwards, the IC clears this bit indicating the fuel gauge calculations are now up to date. This takes between 445ms and 1.845s depending on whether the IC was in a powered state prior to the cell-insertion event. EDet--Empty Detection. This bit is set to 1 when the IC detects that the cell empty point has been reached. This bit is reset to 0 when the cell voltage rises above the recovery threshold. See the V_empty register for details. X--Don't Care. This bit is undefined and can be logic 0 or 1. AtRate Register (04h) The AtRate register allows host software to estimate remaining capacity, SOC, and time to empty for a theoretical load current. Whenever the AtRate register is programmed to 0 or a positive value, the device uses A/D measurements for determining the SOCAV, RemCapAV, and TTE register values. Whenever the AtRate register is programmed to a negative value indicating a hypothetical discharge current, the SOCAV, RemCapAV, and TTE registers calculate their values for the AtRate register theoretical current instead. The AtRate register holds a two's-complement 16-bit value. Do not write 8000h to this register. Figure 36 shows the AtRate register format. Power-Up and Power-On Reset Any power-on reset (POR) of the device resets all memory locations to their default POR value. This removes any custom cell characterization and application data, affects ALRT interrupt and shutdown mode settings, and resets all learned adjustments made by the fuel gauge. To maintain accuracy of the fuel gauge and reset operation settings of the device, the host must reload all application memory data and restore all learned fuelgauge information. Note that the device may take up to 445ms to completely reset operation after a POR event occurs. See Figure 37. Saved data should not be restored until after this period is over. The following procedure is recommended: 1) Read Status register. If POR = 0, exit. 2) Wait 600ms for POR operation to fully complete. 3) Restore all application register values. 4) Restore fuel gauge learned-value information (see the Save and Restore Registers section). 5) Clear POR bit. MSB--ADDRESS 04h S 214 213 212 211 MSb 210 LSB--ADDRESS 04h 29 28 27 LSb MSb 26 25 24 23 22 21 20 LSb 20 UNITS: 1.5625V/RSENSE X = DON'T CARE Figure 36. AtRate Register Format (Input) www.maximintegrated.com Maxim Integrated 27 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 VBATT 1.4s UNTIL NEXT TEMPERATURE READING AIN 270ms A/D READINGS 175ms OUTPUT REGISTERS CELL INSERTION VBATT > VDDMIN A/D MEASUREMENTS COMPLETE SOC VALUES UPDATED Figure 37. Power-Up Operation Save and Restore Registers The device is designed to operate outside the battery pack and can therefore be exposed to power loss when in the application. To prevent the loss of learned information during power cycles, a save-and-restore procedure can be used to maintain register values in nonvolatile memory external to the device. The registers (Table 2) must be stored externally and then rewritten to the device after power-up to maintain a learned state of operation. Note that some registers are application outputs, some registers are for internal calculations, and some are characterization setup registers. Registers that are not internal are described in their own sections. These values should be stored by the application at periodic intervals. Some recommended back-up events are: * End-of-charge * End-of-discharge * Prior to application entering shutdown state The host is responsible for loading the default characterization data at first power-up of the device, and restoring the default characterization data plus learned information on subsequent power-up events. www.maximintegrated.com Table 2. Save and Restore Registers REGISTER ADDRESS FullCap 10h Cycles 17h RCOMP0 38h TempCo 39h QResidual 00 12h QResidual 10 22h QResidual 20 32h QResidual 30 42h dQacc 45h dPacc 46h Battery Removal and Insertion The device detects when a cell has been removed or inserted into the application. This allows the device to adjust to the new cell to maintain accuracy. The removaldetection feature also allows the device to quickly warn the host processor through interrupt of impending power loss if enabled. Maxim Integrated 28 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Detection occurs by monitoring the AIN pin voltage compared to the THRM pin. Whenever a cell is present, the external resistor-divider network sets the voltage of AIN. When the cell is removed, the remaining external resistor pulls AIN to the THRM pin voltage level. Whenever VAIN < VTHRM - VDETF, the device determines that a cell is present in the application. If VAIN > VTHRM - VDETR, the device determines that no cell is present at that time. inserted cell. This process can take up to 1.845s (FTHRM = 0) or 620ms (FTHRM = 1) from time of insertion. Note that the device uses the cell voltage as a starting point for the fuel gauge. If the cell voltage is not fully relaxed at time of insertion, the fuel gauge begins with some initial error. See the Fuel-Gauge Learning and Age Support section for details. The host can disable this feature by clearing the enBi1 bit in the MiscCFG register. Cell Insertion (IC Already Powered) The device can also be configured to alert the host when cell insertion occurs. When Bei = 1 in the CONFIG register, the device generates an interrupt on the ALRT pin at the start of the first temperature conversion after insertion. This could take up to 1.4s to occur. This feature is useful if the application uses more than one cell type and the IC must be reconfigured at each insertion. The device is ready to detect a cell insertion if either the ETHRM or FTHRM bits of the CONFIG register are set to enable the THRM pin output. See Figure 38. When a cell insertion is detected, the fuel gauge is reset and all fuelgauge outputs are updated to reflect the SOC of the newly CELL INSERTION FROM POWERED STATE (FTHRM = 0) VBATT UP TO 1.4s AIN 270ms A/D READINGS 175ms OUTPUT REGISTERS A/D CELL INSERTION MEASUREMENTS DETECTED COMPLETE CELL INSERTION SOC VALUES UPDATED CELL INSERTION FROM POWERED STATE (FTHRM = 1) VBATT UP TO 175ms AIN 270ms A/D READINGS 175ms OUTPUT REGISTERS CELL INSERTION CELL A/D INSERTION MEASUREMENTS DETECTED COMPLETE SOC VALUES UPDATED Figure 38. Operation After Cell Insertion www.maximintegrated.com Maxim Integrated 29 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Modes of Operation Cell Removal The device detects a cell removal if either the ETHRM or FTHRM bits of the CONFIG register are set to enable the THRM pin output. Cell removal does not affect IC operation. The device continues to update fuel-gauge outputs. The host should monitor the Br and Bst bits of the Status register to determine if the fuel-gauge outputs are valid. The device operates in one of two power modes: active and shutdown. While in active mode, the device operates as a high-precision battery monitor with temperature, voltage, auxiliary inputs, current, and accumulated current measurements acquired continuously, and the resulting values updated in the measurement registers. READ and WRITE access is allowed only in active mode. The device can also be configured to alert the host when cell removal occurs. When Ber = 1 in the CONFIG register, the device generates an interrupt on the ALRT pin at the start of the first temperature conversion after removal. This could take up to 1.4s to occur. This feature is useful if the application uses more than one cell type and the IC must be reconfigured at each insertion. In shutdown mode, the LDO is disabled and all activity stops, although volatile RAM contents remain preserved. All A/D register and fuel-gauge output values are maintained. There are several options for entering shutdown: Entering shutdown: Fast Detection of Cell Removal The device can be configured to quickly alert the host of impending power loss on cell removal. This fast response allows the system to quickly and gracefully hibernate to prevent power loss during battery swap. When Ber = 1, FTHRM = 1, and ALRTp = 0 in the CONFIG register, an interrupt on the ALRT pin is generated within 100s after VAIN becomes greater than VTHRM - VDETR. If fast detection is used, it is recommended that all other IC interrupts are disabled to prevent the host from spending time determining the cause of the interrupt. Fast detection of cell removal has no affect on fuel-gauge operation, but leaving the external resistor-divider active increases current consumption of the application. See Figure 39. VBATT * SHUTDOWN command--Write the CONFIG register SHDN = 1 through the I2C interface; wait for longer than the SHDNTIMER register value. * Pack removal--Pack removal detection is valid for longer than the SHDNTIMER register value and the CONFIG register AINSH = 1. * I2C shutdown--I2C lines both persist low for longer than the SHDNTIMER register value and the CONFIG register I2CSH = 1. * ALRT shutdown--Shutdown occurs when the ALRT line is externally driven low for longer than the SHDNTIMER register value (ALSH = 1 and ALRTp = 0), or the ALRT line is externally driven high for longer than the SHDNTIMER register value (ALSH = 1 and ALRTp = 1). See the CONFIG Register (1Dh) section. CELL REMOVAL (Ber = 1, FTHRM = 1) AIN < 100s ALRT OUTPUT CELL REMOVAL INTERRUPT GENERATED Figure 39. Fast Detection of Cell Removal www.maximintegrated.com Maxim Integrated 30 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 These shutdown entry modes are all programmable according to application. Shutdown events are gated by the SHDNTIMER register, which allows a long delay between the shutdown event and the actual shutdown. By behaving this way, the device takes the best reading of the relaxation voltage. if the pin is configured to be logic-low when inactive, the external pullup increases current drain. The ALRTp bit in the CONFIG register sets the polarity of the ALRT pin output. Alerts can be triggered by any of the following conditions: * Battery removal--(VAIN > VTHRM - VDETR) and battery removal detection enabled (Ber = 1). * Battery insertion--(VAIN < VTHRM - VDETF) and battery insertion detection enabled (Bei = 1). * Over-/undervoltage--VALRT threshold violation (upper or lower) and alerts enabled (Aen = 1). See the Status and Configuration section for detailed descriptions of the SHDNTIMER and CONFIG registers. * Over-/undertemperature--TALRT threshold violation (upper or lower) and alerts enabled (Aen = 1). The state of the device when returning to active mode differs depending on the triggering event. See Figure 40. Host software can monitor the POR and Bi status bits to determine what type of event has occurred. * Over/under SOC--SALRT threshold violation (upper or lower) and alerts enabled (Aen = 1). Exiting shutdown: * I2C Wakeup--Any edge on SCL/SDA. * ALRT Wakeup--Any edge on ALRT line and (ALSH = 1 or I2CSH = ALSH = 0). * Reset--IC is power cycled. ALRT Function The Alert Threshold registers allow interrupts to be generated by detecting a high or low voltage, a high or low temperature, or a high or low SOC. Interrupts are generated on the ALRT pin open-drain output driver. An external pullup is required to generate a logic-high signal. Note that EVENT BATTERY INSERTION DETECTED (THRM COMPARATOR RECOGNIZES CHANGE FROM REMOVAL TO INSERTED STATE) WAKE FROM SHUTDOWN STATE (I2C EDGE OR ALRT EDGE DETECTED) POWER-ON RESET (RECOVERY FROM POWER LOSS) To prevent false interrupts, the threshold registers should be initialized before setting the Aen bit. Alerts generated by battery insertion or removal can only be reset by clearing the corresponding bit in the Status register. Alerts generated by a threshold-level violation can be configured to be cleared only by software, or cleared automatically when the threshold level is no longer violated. See the CONFIG (1Dh) register description for details of the alert function configuration. ACTION FUEL GAUGE RESET MaxMinVoltage REGISTER (1Bh) RESET Cycles REGISTER (17h) RESET ALL OTHER RAM VALUES MAINTAINED ALL RAM VALUES MAINTAINED FUEL GAUGE RESTARTS FROM POINT MAINTAINED WHEN SHUTDOWN WAS ENTERED ALL RAM RESET TO DEFAULT VALUES FUEL GAUGE RESET STATUS INDICATORS DNR = 1 Bi = 1 POR = UNCHANGED DNR = 0 Bi = UNCHANGED POR = UNCHANGED DNR = 1 Bi = 0 POR = 1 Figure 40. Device State Based on Shutdown Exit Condition www.maximintegrated.com Maxim Integrated 31 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 VALRT Threshold Register (01h) The VALRT Threshold register (Figure 41) sets upper and lower limits that generate an ALRT pin interrupt if exceeded by the VCELL register value. The upper 8 bits set the maximum value and the lower 8 bits set the minimum value. Interrupt threshold limits are selectable with 20mV resolution over the full operating range of the VCELL register. At power-up, the thresholds default to their maximum settings--FF00h (disabled). TALRT Threshold Register (02h) The TALRT Threshold register sets upper and lower limits that generate an ALRT pin interrupt if exceeded by the Temperature register value. The upper 8 bits set the maximum value and the lower 8 bits set the minimum value. Interrupt threshold limits are stored in two's-complement format and are selectable with 1C resolution over the full operating range of the Temperature register. At power-up, the thresholds default to their maximum settings--7F80h (disabled). Figure 42 shows the TALRT Threshold register format. SALRT Threshold Register (03h) The SALRT Threshold register (Figure 43) sets upper and lower limits that generate an ALRT pin interrupt if exceeded by the selected SOCREP, SOCAV, SOCMIX, or SOCVF register values. See the SACFG bits in the MiscCFG register description for details. The upper 8 bits set the maximum value and the lower 8 bits set the minimum value. Interrupt threshold limits are selectable with 1% resolution over the full operating range of the selected SOC register. At power-up, the thresholds default to their maximum settings--FF00h (disabled). MSB--ADDRESS 01h LSB--ADDRESS 01h MAX7 MAX6 MAX5 MAX4 MAX3 MAX2 MAX1 MAX0 MIN7 MIN6 MIN5 MIN4 MIN3 MIN2 MIN1 MIN0 MSb MSb LSb LSb UNITS: 20mV Figure 41. VALRT Threshold Register Format (Input) MSB--ADDRESS 02h S LSB--ADDRESS 02h MAX6 MAX5 MAX4 MAX3 MAX2 MAX1 MAX0 MSb LSb S MIN6 MIN5 MIN4 MIN3 MIN2 MIN1 MIN0 MSb LSb UNITS: 1C Figure 42. TALRT Threshold Register Format (Input) MSB--ADDRESS 03h LSB--ADDRESS 03h MAX7 MAX6 MAX5 MAX4 MAX3 MAX2 MAX1 MAX0 MIN7 MIN6 MIN5 MIN4 MIN3 MIN2 MIN1 MIN0 MSb MSb LSb LSb UNITS: 1% Figure 43. SALRT Threshold Register Format (Input) www.maximintegrated.com Maxim Integrated 32 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Status and Configuration The following registers control operation of the ALRT interrupt feature, control transition between active and shutdown modes of operation, and provide status updates to the host processor. CONFIG Register (1Dh) The CONFIG register holds all shutdown enable, alert enable, and temperature enable control bits. Writing a bit location enables the corresponding function within a 175.8ms task period. Figure 44 shows the CONFIG register format. 0--Bit must be written 0. Do not write 1. Ber--Enable alert on battery removal. When Ber = 1, a battery-removal condition, as detected by the AIN pin voltage, triggers an alert. Set to 0 at power-up. Note that if this bit is set to 1, the ALSH bit should be set to 0 to prevent an alert condition from causing the device to enter shutdown mode. Bei--Enable alert on battery insertion. When Bei = 1, a battery-insertion condition, as detected by the AIN pin voltage, triggers an alert. Set to 0 at power-up. Note that if this bit is set to 1, the ALSH bit should be set to 0 to prevent an alert condition from causing the device to enter shutdown mode. Aen--Enable alert on fuel-gauge outputs. When Aen = 1, violation of any of the alert threshold register values by temperature, voltage, or SOC triggers an alert. This bit affects the ALRT pin operation only. The Smx, Smn, Tmx, Tmn, Vmx, and Vmn bits are not disabled. This bit is set to 0 at power-up. Note that if this bit is set to 1, the ALSH bit should be set to 0 to prevent an alert condition from causing the device to enter shutdown mode. FTHRM--Force Thermistor Bias Switch. This allows the host to control the bias of the thermistor switch or enable fast detection of battery removal (see the Fast Detection of Cell Removal section). Set FTHRM = 1 to always enable the thermistor bias switch. With a standard 10k thermistor, this adds an additional ~200A to the current drain of the circuit. This bit is set to 0 at power-up. ETHRM--Enable Thermistor. Set to logic 1 to enable the automatic THRM output bias and AIN measurement every 1.4s. This bit is set to 1 at power-up. ALSH--ALRT Shutdown. Set to logic 1 and clear the Aen, Ber, and Bei bits to configure the ALRT pin as an input to control shutdown mode of the device. The device enters shutdown if the ALRT pin is held active for longer than timeout of the SHDNTIMER register. The device enters active mode immediately on the opposite edge of the ALRT pin. When set to logic 0, the ALRT pin can function as an interrupt output. This bit is set to 0 at power-up. Note that if this bit is set to 1, the Bei, Ber, and Aen bits should be set to 0 to prevent an alert condition from causing the device to enter shutdown mode. I2CSH--I2C Shutdown. Set to logic 1 to force the device to enter shutdown mode if both SDA and SCL are held low for more than timeout of the SHDNTIMER register. This also configures the device to wake up on a rising edge of either SDA or SCL. Set to 1 at power-up. Note that if I2CSH and AINSH are both set to 0, the device wakes up an edge of any of the SDA, SCL, or ALRT pins. SHDN--Shutdown. Write this bit to logic 1 to force a shutdown of the device after timeout of the SHDNTIMER register. SHDN is reset to 0 at power-up and upon exiting shutdown mode. Tex--Temperature External. When set to 1, the fuel gauge requires external temperature measurements to be written from the host. When set to 0, measurements on the AIN pin are converted to a temperature value and stored in the Temperature register instead. Tex is set to 1 at power-up. Ten--Enable Temperature Channel. Set to 1 and set ETHRM or FTHRM to 1 to enable measurements on the AIN pin. Ten is set to 1 at power-up. MSB--ADDRESS 1Dh 0 SS TS VS ALRTp AINSH MSb LSB--ADDRESS 1Dh Ten Tex SHDN I2CSH ALSH ETHRM FTHRM Aen LSb MSb Bei Ber LSb Figure 44. CONFIG Register Format (Input) www.maximintegrated.com Maxim Integrated 33 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 AINSH--AIN Pin Shutdown. Set to 1 to enable device shutdown when the battery is removed. The IC enters shutdown if the AIN pin remains high (AIN reading > VTHRM - VDETR) for longer than the timeout of the SHDNTIMER register. This also configures the device to wake up when AIN is pulled low on cell insertion. AINSH is set to 0 at power-up. Note that if I2CSH and AINSH are both set to 0, the device wakes up an edge of any of the SDA, SCL, or ALRT pins. SS--SOC ALRT Sticky. When SS = 1, SOC alerts can only be cleared through software. When SS = 0, SOC alerts are cleared automatically when the threshold is no longer exceeded. SS is set to 0 at power-up. ALRTp--ALRT Pin Polarity. Regardless if ALRT is being used as an input or output, if ALRTp = 0, the ALRT pin is active low; if ALRTp = 1, the ALRT pin is active high. ALRTp must be set to 0 to enable fast detection of cell removal. ALRTp is set to 0 at power-up. SHDNTIMER Register (3Fh) VS--Voltage ALRT Sticky. When VS = 1, voltage alerts can only be cleared through software. When VS = 0, voltage alerts are cleared automatically when the threshold is no longer exceeded. VS is set to 0 at power-up. CTR12:CTR0--Shutdown Counter. This register counts the total amount of elapsed time since the shutdown trigger event. This counter value stops and resets to 0 when the shutdown timeout completes. The counter LSb is 1.4s. TS--Temperature ALRT Sticky. When TS = 1, temperature alerts can only be cleared through software. When TS = 0, temperature alerts are cleared automatically when the threshold is no longer exceeded. TS is set to 1 at power-up. TIMER Register (3Eh) This register holds timing information for the fuel gauge. It is available to the user for debug purposes. Figure 45 shows the TIMER register format. The SHDNTIMER register sets the timeout period from when a shutdown event is detected until the device disables the LDO and enters low-power mode. Figure 46 shows the SHDNTIMER register format. THR2:THR0--Sets the shutdown timeout period from a minimum of 45s to a maximum of 1.6h. The default POR value of 7h gives a shutdown delay of 1.6h. The equation setting the period is: Shutdown Timeout Period = 175.8ms x 2(8+THR) MSB--Address 3Eh 215 214 213 212 211 LSB--Address 3Eh 210 29 MSb 28 LSb 27 26 25 24 23 22 MSb 21 20 LSb 20 UNITS: 175.8ms Figure 45. Timer Register Format (Output) MSB--ADDRESS 3Fh LSB--ADDRESS 3Fh THR2 THR1 THR0 CTR12 CTR11 CTR10 CTR9 CTR8 CTR7 CTR6 CTR5 CTR4 CTR3 CTR2 CTR1 CTR0 MSb MSb LSb LSb Figure 46. SHDNTIMER Register Format (Input/Output) www.maximintegrated.com Maxim Integrated 34 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Status Register (00h) The Status register maintains all flags related to alert thresholds and battery insertion or removal. Figure 47 shows the Status register format. POR--Power-On Reset. This bit is set to a 1 when the device detects that a software or hardware POR event has occurred. If the host detects that the POR bit has been set, the device should be reconfigured. See the Power-Up and Power-On Reset section. This bit must be cleared by system software to detect the next POR event. POR is set to 1 at power-up. Bst--Battery Status. This bit is set to 0 when a battery is present in the system and set to 1 when the battery is removed. Bst is set to 0 at power-up. Vmn--Minimum VALRT Threshold Exceeded. This bit is set to a 1 whenever a VCELL register reading is below the minimum VALRT value. This bit may or may not need to be cleared by system software to detect the next event. See VS in the CONFIG register. Vmn is set to 0 at power-up. Tmn--Minimum TALRT Threshold Exceeded. This bit is set to a 1 whenever a Temperature register reading is below the minimum TALRT value. This bit may or may not need to be cleared by system software to detect the next event. See TS in the CONFIG register. Tmn is set to 0 at power-up. Smn--Minimum SOCALRT Threshold Exceeded. This bit is set to a 1 whenever SOC falls below the minimum SOCALRT value. This bit may or may not need to be cleared by system software to detect the next event. See SS in the CONFIG register and SACFG in the MiscCFG register. Smn is set to 0 at power-up. Bi--Battery Insertion. This bit is set to a 1 when the device detects that a battery has been inserted into the system by monitoring the AIN pin. This bit must be cleared by system software to detect the next insertion event. Bi is set to 0 at power-up. Vmx--Maximum VALRT Threshold Exceeded. This bit is set to a 1 whenever a VCELL register reading is above the maximum VALRT value. This bit may or may not need to be cleared by system software to detect the next event. See VS in the CONFIG register. Vmx is set to 0 at power-up. Tmx--Maximum TALRT Threshold Exceeded. This bit is set to a 1 whenever a Temperature register reading is above the maximum TALRT value. This bit may or may not need to be cleared by system software to detect the next event. See TS in the CONFIG register. Tmx is set to 0 at power-up. Smx--Maximum SOCALRT Threshold Exceeded. This bit is set to a 1 whenever SOC rises above the maximum SOCALRT value. This bit may or may not need to be cleared by system software to detect the next event. See SS in the CONFIG register and SACFG in the MiscCFG register. Smx is set to 0 at power-up. Br--Battery Removal. This bit is set to a 1 when the device detects that a battery has been removed from the system. This bit must be cleared by system software to detect the next removal event. Br is set to 0 at power-up. X--Don't Care. This bit is undefined and can be logic 0 or 1. MSB--ADDRESS 00h Br Smx Tmx Vmx Bi Smn MSb LSB--ADDRESS 00h Tmn Vmn X LSb MSb X X X Bst X POR X LSb Figure 47. Status Register Format (Input/Output) www.maximintegrated.com Maxim Integrated 35 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Version Register (21h) The Version register holds a 16-bit value that indicates the version of the device. Figure 48 shows the Version register format. Voltage Measurement While in active mode, the device periodically measures the voltage between the VBATT and CSP pins over a 2.5V to 4.98V range. The resulting data is placed in the VCELL register every 175.8ms with an LSb value of 0.625mV. Additionally, the device maintains a record of the minimum and maximum voltage measured by the device, and an average voltage over a time period defined by the host. Contents of the VCELL and AverageVCELL registers are indeterminate for the first conversion cycle time period after device power-up. The last values of the VCELL and AverageVCELL registers are maintained when the device enters shutdown mode. VCELL Register (09h) While in active mode, the device periodically measures the voltage between the VBATT and CSP pins over a 0 to 4.98V range. The resulting data is placed in the VCELL register every 175.8ms with an LSb value of 0.625mV. Voltages above the maximum register value are reported as the maximum value. The lower 3 bits of the VCELL register are don't care bits. Figure 49 shows the VCELL register format. AverageVCELL Register (19h) The AverageVCELL register reports an average of VCELL register readings over a configurable 12s to 24min time period. See the FilterCFG register description for details on setting the time filter. The resulting average is placed in the AverageVCELL register with an LSb value of 0.625mV. The lower 3 bits of the AverageVCELL register are don't care bits. The first VCELL register reading after device powerup sets the starting point of the AverageVCELL filter. Note that when a cell relaxation event is detected, the averaging period for the AverageVCELL register changes to the period defined by dt3:dt0 in the RelaxCFG register. The AverageVCELL register reverts back to its normal averaging period when a charge or discharge current is detected. Figure 50 shows the AverageVCELL register format. MSB--ADDRESS 21h V15 V14 V13 V12 V11 V10 LSB--ADDRESS 21h V9 MSb V8 V7 LSb MSb V6 V5 V4 V3 V2 V1 V0 LSb Figure 48. Version Register Format (Output) MSB--ADDRESS 09h 212 211 210 29 28 27 LSB--ADDRESS 09h 26 MSb 25 24 LSb MSb 23 22 21 20 X X X LSb UNITS: 0.625mV Figure 49. VCELL Register Format (Output) MSB--ADDRESS 19h 212 211 210 29 28 27 LSB--ADDRESS 19h 26 MSb 25 24 LSb MSb 23 22 21 20 X X X LSb UNITS: 0.625mV Figure 50. AverageVCELL Register Format (Output) www.maximintegrated.com Maxim Integrated 36 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 MaxMinVCELL Register (1Bh) The MaxMinVCELL register maintains the maximum and minimum VCELL register values since the last fuel-gauge reset or until reset by the host software. Each time the VCELL register updates, it is compared against these values. If VCELL is larger than the maximum or less than the minimum, the corresponding value is replaced with the new reading. At power-up, the MaxVCELL value is set to 00h (the minimum) and the MinVCELL value is set to FFh (the maximum). Therefore, both values are changed to the VCELL register reading after the first update. Host software can reset this register by writing it to its powerup value of 00FFh. The maximum and minimum voltages are each stored as 8-bit values with a 20mV resolution. Figure 51 shows the MaxMinVCELL register format. Current Measurement While in active mode, the device periodically measures the voltage between the CSN and CSP pins over a 51.2mV range. The resulting data is stored as a signed two's-complement value in the Current register every 175.8ms with an LSb value of 1.5625V/RSENSE. All devices are calibrated for current-measurement accuracy at the factory. However, if the application requires, Current Register readings can be adjusted by changing the COFF and CGAIN register settings. Additionally, the device maintains a record of the minimum and maximum current measured by the device, and an average current over a time period defined by the host. Contents of the Current and AverageCurrent registers are 0000h until the first conversion cycle time period after IC power-up. The last values of the Current and AverageCurrent registers are maintained when the IC enters shutdown mode. Current Register (0Ah) While in active mode, the device periodically measures the voltage between the CSN and CSP pins over a 51.2mV range. The resulting data is stored as a two'scomplement value in the Current register every 175.8ms with an LSb value of 1.5625V/RSENSE. Voltages outside the minimum and maximum register values are reported as the minimum or maximum value. Figure 52 shows the Current register format and Table 3 shows the Sample Current register conversions. MSB--ADDRESS 1Bh LSB--ADDRESS 1Bh MAX7 MAX6 MAX5 MAX4 MAX3 MAX2 MAX1 MAX0 MIN7 MIN6 MIN5 MIN4 MIN3 MIN2 MIN1 MIN0 MSb MSb LSb LSb UNITS: 20mV Figure 51. MaxMinVCELL Register Format (Output) Table 3. Sample Current Register Conversions FUNCTION Adjusting sense resistor to meet range and accuracy requirements Adjusting CGAIN to keep units constant www.maximintegrated.com SENSE RESISTOR () CGAIN REGISTER CURRENT REGISTER RESOLUTION (A) CURRENT REGISTER RANGE (A) MAXIMUM CELL CAPACITY (Ah) 0.005 4000h 312.50 10.24 32.768 0.010 4000h 156.25 5.12 16.384 0.020 4000h 78.125 2.56 8.192 0.005 7FFFh 156.25 5.12 16.384 0.010 4000h 156.25 5.12 16.384 0.020 2000h 156.25 5.12 16.384 Maxim Integrated 37 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 AverageCurrent Register (0Bh) The AverageCurrent register reports an average of current-register readings over a configurable 0.7s to 6.4h time period. See the FilterCFG register description for details on setting the time filter. The resulting average is placed in the AverageCurrent register with an LSb value of 1.5625V/ RSENSE. The first Current register reading after device power-up sets the starting point of the AverageCurrent filter. The last value of the AverageCurrent register is maintained when the device enters shutdown mode. Figure 53 shows the AverageCurrent register format. MaxMinCurrent Register (1Ch) The MaxMinCurrent register maintains the maximum and minimum Current register values since the last fuel gauge reset or until cleared by host software. Each time the Current register updates, it is compared against these values. If the reading is larger than the maximum or less than the minimum, the corresponding value is replaced with the new reading. At power-up, the MaxCurrent value is set to 80h (the minimum) and the MinCurrent value is set to 7Fh (the maximum). Therefore, both values are changed to the Current register reading after the first update. Host software can reset this register by writing it to its power-up value of 807Fh. The maximum and minimum voltages are each stored as two's-complement 8-bit values with 0.4mV/RSENSE resolution. Figure 54 shows the MaxMinCurrent register format. CGAIN Register (2Eh)/COFF Register (2Fh) The CGAIN and COFF registers adjust the gain and offset of the current measurement result. The current measurement A/D is factory trimmed to data-sheet accuracy without the need for the user to make further adjustments. The default power-up settings for CGAIN and COFF apply no adjustments to the Current register reading. For specific application requirements, the CGAIN and COFF registers can be used to adjust readings as follows: Current Register = Current A/D Reading x (CGAIN Register/16384) + (2 x COFF Register) For easiest software compatibility between systems, configure CGAIN to keep current LSb resolution at 0.15625mA. A minimum sense resistance of 0.005 is required due to the maximum range of CGAIN. This preserves resolution of current readings and capacities. MSB--ADDRESS 0Ah S 214 213 212 211 210 LSB--ADDRESS 0Ah 29 MSb 28 27 LSb MSb 26 25 24 23 22 21 20 LSb UNITS: 1.5625V/RSENSE Figure 52. Current Register Format (Output) MSB--ADDRESS 0Bh S 214 213 212 211 210 LSB--ADDRESS 0BH 29 MSb 28 27 LSb MSb 26 25 24 23 22 21 20 LSb UNITS: 1.5625V/RSENSE Figure 53. AverageCurrent Register Format (Output) MSB--ADDRESS 1Ch S LSB--ADDRESS 1Ch MAX6 MAX5 MAX4 MAX3 MAX2 MAX1 MAX0 MSb LSb S MIN6 MIN5 MIN4 MIN3 MIN2 MIN1 MIN0 MSb LSb UNITS: 0.4mV/RSENSE Figure 54. MaxMinCurrent Register Format (Output) www.maximintegrated.com Maxim Integrated 38 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Both these registers are signed two's complement. The default values of 4000h for CGAIN and 0000h for COFF preserve factory calibration and unit values (1.5625V). Figure 55 shows the CGAIN register format and Figure 56 shows the COFF register format. Temperature Measurement While in active mode and Ten = 1 in the CONFIG register, the device periodically measures the voltage between the AIN and CSP pins and compares the result to the voltage of the THRM pin. The device stores the result, a ratiometric value from 0 to 100%. The resulting data is placed in the AIN register every 1.4s with an LSb of 0.0122%. Conversions are initiated by connecting the THRM and VTT pins internally. This enables the active pullup to the external voltage-divider network. After the pullup is enabled, the device waits for a settling period of tPRE prior to making measurements on the AIN pin. When ETHRM = 1, FTHRM = 0, the active pullup is disabled when temperature measurements are complete. This feature limits the time the external resistor-divider network is active and lowers the total amount of energy used by the system. When Tex = 0 and Ten = 1 in the CONFIG register, the device converts the AIN register to a temperature using the temperature gain (TGAIN) and temperature offset (TOFF) register values: Temperature Register = (AIN Register x TGAIN Register/16384) + (TOFF Register x 2) The resulting value is stored in the Temperature register each time the AIN register is updated. Additionally, the device maintains a record of the minimum and maximum temperature measured by the device, and an average temperature over a time period defined by the host. Table 4 lists the recommended TGAIN and TOFF register values for common NTC thermistors. MSB--ADDRESS 2Eh 20 S 2-1 2-2 2-3 2-4 LSB--ADDRESS 2Eh 2-5 MSb 2-6 2-7 LSb MSb 2-8 2-9 2-10 2-11 2-12 2-13 2-14 LSb 20 UNITS: 0.0061% Figure 55. CGAIN Register Format (Input) MSB--ADDRESS 2FH 214 S 213 212 211 210 MSb LSB--ADDRESS 2Fh 29 28 27 LSb MSb 26 25 24 23 22 21 20 LSb UNITS: 3.125V/RSENSE Figure 56. COFF Register Format (Input) Table 4. Recommended TGAIN and TOFF Register Values for Common NTC Thermistors THERMISTOR R25C (k) BETA RECOMMENDED TGAIN RECOMMENDED TOFF Semitec 103AT-2 10 3435 E3E1h 290Eh Fenwal 197-103LAG-A01 10 3974 E71Ch 251Ah TDK Type F 10 4550 E989h 22B1h www.maximintegrated.com Maxim Integrated 39 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 When Tex = 1 in the CONFIG register, the device does not update the Temperature register based on results from the AIN pin A/D. Instead, host software must periodically write the Temperature register with the known application temperature to keep the fuel gauge accurate. AIN Register (27h) While in active mode and Ten = 1 in the CONFIG register, the device periodically measures the voltage between pins AIN and CSP and compares the result to the voltage of the THRM pin. The device stores the result, a ratiometric value from 0 to 100%. The resulting data is placed in the AIN register every 1.4s with an LSb of 0.0122%. Contents of the AIN register are indeterminate for the first conversion cycle time period after device power-up. The last value of the AIN register is maintained when the device enters shutdown mode or if Ten = 0 in the CONFIG register. Figure 57 shows the AIN register format. Temperature Register (08h) While in active mode and Tex = 0 and Ten = 1 in the CONFIG register, the device converts the AIN register value into a signed two's-complement temperature value. See the TGAIN and TOFF configuration registers. The resulting data is placed in the Temperature register every 1.4s with a resolution of +0.0039C. If an 8-bit temperature reading is desired, the host can read only the upper byte of the Temperature register with a resolution of +1.0C. Contents of the Temperature register are indeterminate for the first conversion cycle time period after device power-up. The last value of the Temperature register is maintained when the device enters shutdown mode. Figure 58 shows the Temperature register format. AverageTemperature Register (16h) The AverageTemperature register reports an average of temperature register readings over a configurable 6min to 12h time period. See the FilterCFG register (29h) description for details on setting the time filter. The resulting average is placed in the AverageTemperature register with an LSb value of 0.0039C. The first Temperature register reading after device power-up sets the starting point of the AverageTemperature filter. The last value of the AverageTemperature register is maintained when the device enters shutdown mode. Figure 59 shows the AverageTemperature register format. MSB--ADDRESS 27h 2-1 2-2 2-3 2-4 2-5 2-6 LSB--ADDRESS 27h 2-7 MSb 2-8 2-9 LSb MSb 2-10 2-11 2-12 2-13 X X X LSb 2-13 UNITS: 0.0122% Figure 57. AIN Register Format (Output) MSB--ADDRESS 08h S 26 25 24 23 22 LSB--ADDRESS 08h 21 MSb 20 2-1 LSb MSb 2-2 2-3 2-4 2-5 2-6 2-7 2-8 LSb 2-8 UNITS: +0.0039C 20 UNITS: +1.0C Figure 58. Temperature Register Format (Input/Output) MSB--ADDRESS 16h S 26 25 MSb 24 23 22 LSB--ADDRESS 16h 21 20 2-1 LSb MSb 2-2 2-3 2-4 2-5 2-6 2-7 2-8 LSb 2-8 UNITS: +0.0039C 20 UNITS: +1.0C Figure 59. AverageTemperature Register Format (Output) www.maximintegrated.com Maxim Integrated 40 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 MaxMinTemperature Register (1Ah) The MaxMinTemperature register maintains the maximum and minimum Temperature register values since the last fuel-gauge reset or until cleared by host software. Each time the Temperature register updates, it is compared against these values. If the reading is larger than the maximum or less than the minimum, the corresponding values are replaced with the new reading. At power-up, the MaxTemperature value is set to 80h (minimum) and the MinTemperature value is set to 7Fh (maximum). Therefore, both values are changed to the Temperature register reading after the first update. Host software can reset this register by writing it to its power-up value of 807Fh. The maximum and minimum temperatures are each stored as two's complement 8-bit values with 1C resolution. Figure 60 shows the MaxMinTemperature register format. TGAIN Register (2Ch)/TOFF Register (2Dh) The TGAIN and TOFF registers adjust the gain and offset of the temperature measurement A/D on the AIN pin to convert the result to a temperature value by the following equation: Both these registers are signed two's complement. These registers allow for accurate temperature conversions when using a variety of external NTC thermistors (see Table 4). Figure 61 shows the TGAIN register format and Figure 62 shows the TOFF register format. IC Memory Map The device has a 256- word linear memory space containing all user-accessible registers. All registers are 16 bits wide and are read and written as 2-byte values. When the MSB of a register is read, the MSB and LSB are latched simultaneously and held for the duration of the Read Data command. This prevents updates to the LSB during the read, ensuring synchronization between the 2 register bytes. All locations are volatile RAM and lose their data in the event of power loss. Data is retained during device shutdown. Each register has a power-on-reset value that it defaults to at power-up. Word addresses designated as reserved return an undetermined when read. These locations should not be written. Temperature Register = (AIN Register x TGAIN Register/16384) + (TOFF Register x 2) MSB--ADDRESS 1Ah LSB--ADDRESS 1Ah MAX6 MAX5 MAX4 MAX3 MAX2 MAX1 MAX0 S MSb LSb S MIN6 MIN5 MIN4 MIN3 MIN2 MIN1 MIN0 MSb LSb UNITS: +1C Figure 60. MaxMinTemperature Register Format (Output) MSB--ADDRESS 2Ch S 214 213 212 211 MSb 210 LSB--ADDRESS 2Ch 29 28 27 LSb MSb 26 25 24 23 22 21 20 LSb 20 UNITS: +1C/64 Figure 61. TGAIN Register Format (Input) www.maximintegrated.com Maxim Integrated 41 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 MSB--ADDRESS 2Dh S 27 26 25 24 23 LSB--ADDRESS 2Dh 22 MSb 21 20 LSb MSb 2-1 2-2 2-3 2-4 2-5 2-6 2-7 LSb 2-7 UNITS: +0.0078C Figure 62. TOFF Register Format (Input) Table 5. Device Memory Map ADDRESS (HEX) REGISTER NAME 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 10h 11h 12h 13h 14h-15h 16h 17h 18h 19h 1Ah 1Bh 1Ch 1Dh 1Eh 1Fh 20h 21h Status VALRT Threshold TALRT Threshold SALRT Threshold AtRate RemCapREP SOCREP Age Temperature VCELL Current AverageCurrent RESERVED SOCMIX SOCAV RemCapMIX FullCAP TTE QResidual 00 FullSOCThr RESERVED AverageTemperature Cycles DesignCap AverageVCELL MaxMinTemperature MaxMinVCELL MaxMinCurrent CONFIG ICHGTerm RemCapAV RESERVED Version www.maximintegrated.com A/D ALERT/ MG m3 MG m3 MG m3 MG m3 MG m3 POR APP CELL SAVE AND CONFIG OUTPUT VALUE RESTORE MEASURE STATUS DATA DATA u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u 0002h FF00h 7F80h FF00h 0000h 03E8h 3200h 6400h 1600h B400h 0000h 0000h -- 3200h 3200h 03E8h 07D0h 0000h 1E2Fh 4600h -- 1600h 0000h 07D0h B400h 807Fh 00FFh 807Fh 2350h 03C0h 03E8h -- 00ACh READ/ WRITE R/W R/W R/W R/W R/W R R R R/W R R R -- R R R R/W R R/W R/W -- R R/W R/W R R/W R/W R/W R/W R/W R -- R Maxim Integrated 42 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Table 5. Device Memory Map (continued) ADDRESS (HEX) REGISTER NAME 22h 23h 24h 25h 26h 27h 28h 29h 2Ah 2Bh 2Ch 2Dh 2Eh 2Fh 30h-31h 32h 33h-35h 36h 37h 38h 39h 3Ah 3Bh 3Ch 3Dh 3Eh 3Fh 40h-41h 42h 43h-44h 45h 46h 47h-4Ch 4Dh 4Eh-7Fh QResidual 10 FullCapNom TempNom TempLim RESERVED AIN LearnCFG FilterCFG RelaxCFG MiscCFG TGAIN TOFF CGAIN COFF RESERVED QResidual 20 RESERVED Iavg_empty FCTC RCOMP0 TempCo V_empty RESERVED RESERVED FSTAT TIMER SHDNTIMER RESERVED QResidual 30 RESERVED dQacc dPacc RESERVED QH RESERVED 80h-AFh Characterization Table B0h-FAh FBh FCh-FEh FFh RESERVED VFOCV RESERVED SOCVF www.maximintegrated.com A/D ALERT/ MG m3 MG m3 MG m3 MG m3 MG m3 POR APP CELL SAVE AND CONFIG OUTPUT VALUE RESTORE MEASURE STATUS DATA DATA u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u READ/ WRITE 1E00h 07D0h 1400h 2305h -- 88D0h 2602h 4EA4h 203Bh 0870h E3E1h 290Eh 4000h 0000h -- 1306h -- 0780h 05E0h 004Bh 262Bh 9C5Ch -- -- 0001h 0000h E000h -- 0C00h -- 007Dh 0C80h -- 0000h -- R/W R/W R/W R/W -- R R/W R/W R/W R/W R/W R/W R/W R/W -- R/W -- R/W R/W R/W R/W R/W -- -- R R R/W -- R/W -- R/W R/W -- R/W -- N/A R/W -- 0000h -- 0000h -- R -- R Maxim Integrated 43 MAX17047/MAX17050 2-Wire Bus System The 2-wire bus system supports operation as a slave-only device in a single or multislave, and single or multimaster system. Up to 128 slave devices may share the bus by uniquely setting the 7-bit slave address. The 2-wire interface consists of a serial data line (SDA) and serial clock line (SCL). SDA and SCL provide bidirectional communication between the IC (slave device) and a master device at speeds up to 400kHz. The device's SDA pin operates bidirectionally, that is, when the device receives data, SDA operates as an input, and when the device returns data, SDA operates as an open-drain output, with the host system providing a resistive pullup. The device always operates as a slave device, receiving and transmitting data under the control of a master device. The master initiates all transactions on the bus and generates the SCL signal, as well as the START and STOP bits, which begin and end each transaction. Bit Transfer One data bit is transferred during each SCL clock cycle, with the cycle defined by SCL transitioning low to high and then high to low. The SDA logic level must remain stable during the high period of the SCL clock pulse. Any change in SDA when SCL is high is interpreted as a START or STOP control signal. Bus Idle The bus is defined to be idle, or not busy, when no master device has control. Both SDA and SCL remain high when the bus is idle. The STOP condition is the proper method to return the bus to the idle state. START and STOP Conditions The master initiates transactions with a START condition (S), by forcing a high-to-low transition on SDA while SCL is high. The master terminates a transaction with a STOP condition (P), a low-to-high transition on SDA while SCL is high. A Repeated START condition (Sr) can be used in place of a STOP then START sequence to terminate one transaction and begin another without returning the bus to the idle state. In multimaster systems, a Repeated START allows the master to retain control of the bus. The START and STOP conditions are the only bus activities in which the SDA transitions when SCL is high. Acknowledge Bits Each byte of a data transfer is acknowledged with an Acknowledge bit (A) or a No Acknowledge bit (N). Both the master and the device slave generate acknowledge bits. www.maximintegrated.com 1-Cell Fuel Gauge with ModelGauge m3 To generate an Acknowledge, the receiving device must pull SDA low before the rising edge of the acknowledgerelated clock pulse (ninth pulse) and keep it low until SCL returns low. To generate a No Acknowledge (also called NACK), the receiver releases SDA before the rising edge of the acknowledge-related clock pulse and leaves SDA high until SCL returns low. Monitoring the acknowledge bits allows for detection of unsuccessful data transfers. An unsuccessful data transfer can occur if a receiving device is busy or if a system fault has occurred. In the event of an unsuccessful data transfer, the bus master should reattempt communication. Data Order A byte of data consists of 8 bits ordered most significant bit (MSb) first. The least significant bit (LSb) of each byte is followed by the Acknowledge bit. Device registers composed of multibyte values are ordered least significant byte (LSB) first. Slave Address A bus master initiates communication with a slave device by issuing a START condition followed by a Slave Address (SAddr) and the read/write (R/W) bit. When the bus is idle, the device continuously monitors for a START condition followed by its slave address. When the device receives a slave address that matches the value in its Programmable Slave Address register, it responds with an Acknowledge bit during the clock period following the R/W bit. The 7-bit Programmable Slave Address register is factory programmed and cannot be changed by the user. IC SLAVE ADDRESS 0110110 Read/Write Bit The R/W bit following the slave address determines the data direction of subsequent bytes in the transfer. R/W = 0 selects a write transaction, with the following bytes being written by the master to the slave. R/W = 1 selects a read transaction, with the following bytes being read from the slave by the master. Bus Timing The device is compatible with any bus timing up to 400kHz. No special configuration is required to operate at any speed. 2-Wire Command Protocols The command protocols involve several transaction formats. The simplest format consists of the master writing the START bit, slave address, R/W bit, and then monitor- Maxim Integrated 44 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 ing the acknowledge bit for presence of the device. More complex formats such as the write Data, read Data, and Function command protocols write data, read data, and execute device-specific operations, respectively. All bytes in each command format require the slave or the host system to return an Acknowledge bit before continuing with the next byte. Each function command definition outlines the required transaction format. Table 6 applies to the transaction formats. Basic Transaction Formats Write: S SAddr W A MAddr A DataL A DataH A P A write transaction transfers 1 or more data bytes to the device. The data transfer begins at the memory address supplied in the MAddr byte. Control of the SDA signal is retained by the master throughout the transaction, except for the Acknowledge cycles. Read: S SAddr W A MAddr A Sr SAddr R A DataL A DataH N P write Portion read Portion A read transaction transfers one or more words from the IC. Read transactions are composed of two parts, a write portion followed by a read portion, and are therefore inherently longer than a write transaction. The write portion communicates the starting point for the read operation. The read portion follows immediately, beginning with a Repeated START, Slave Address with R/W set to a 1. Control of SDA is assumed by the IC beginning with the Slave Address Acknowledge cycle. Control of the SDA signal is retained by the device throughout the transaction, except for the Acknowledge cycles. The master indicates the end of a read transaction by responding to the last Table 6. 2-Wire Protocol Key KEY S DESCRIPTION KEY DESCRIPTION START bit Sr Repeated START SAddr Slave Address (7 bit) W R/W bit = 0 FCmd Function Command byte R R/W bit = 1 MAddr Memory Address byte P STOP bit Data Data byte written by Master Data Data byte returned by Slave A Acknowledge bit-- Master A Acknowledge bit-- Slave N No Acknowledge-- Master N No Acknowledge-- Slave www.maximintegrated.com byte it requires with a No Acknowledge. This signals the device that control of SDA is to remain with the master following the Acknowledge clock. Write Data Protocol The write Data protocol is used to write to register and shadow RAM data to the IC starting at memory address MAddr. Data0 represents the data written to MAddr, Data1 represents the data written to MAddr + 1, and DataN represents the last data byte written to MAddr + N. The master indicates the end of a write transaction by sending a STOP or Repeated START after receiving the last acknowledge bit: S SAddr W A MAddr A DataL0 A DataH0 A DataL1 A DataH1 A ... DataLN A DataHN A P The MSb of the data to be stored at address MAddr can be written immediately after the MAddr byte is acknowledged. Because the address is automatically incremented after the least significant bit (LSb) of each byte is received by the device, the MSb of the data at address MAddr + 1 can be written immediately after the acknowledgment of the data at address MAddr. If the bus master continues an autoincremented write transaction beyond address FFh, the device ignores the data. Data is also ignored on writes to read-only addresses but not reserved addresses. Do not write to reserved address locations. Read Data Protocol The read data protocol is used to read register and shadow RAM data from the device starting at memory address specified by MAddr. Data0 represents the data byte in memory location MAddr, Data1 represents the data from MAddr + 1, and DataN represents the last byte read by the master: S SAddr W A MAddr A Sr SAddr R A DataL0 A DataH0 A DataL1 A DataH1 A ...DataLN N DataHN N P Data is returned beginning with the most significant bit (MSb) of the data in MAddr. Because the address is automatically incremented after the LSb of each byte is returned, the MSb of the data at address MAddr +1 is available to the host system immediately after the acknowledgment of the data at address MAddr. If the bus master continues to read beyond address FFh, the device outputs data values of FFh. Addresses labeled Reserved in the memory map return undefined data. The bus master terminates the read transaction at any byte boundary by issuing a No Acknowledge followed by a STOP or Repeated START. Maxim Integrated 45 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Ordering Information PART Package Information TEMP RANGE PIN-PACKAGE MAX17047G+ -40C to +85C 10 TDFN-EP* MAX17047G+T10 -40C to +85C 10 TDFN-EP* MAX17050X+ -40C to +85C 9 WLP MAX17050X+T10 -40C to +85C 9 WLP +Denotes a lead(Pb)-free/RoHS-compliant package. T = Tape and reel. *EP = Exposed pad. www.maximintegrated.com For the latest package outline information and land patterns (footprints), go to www.maximintegrated.com/packages. Note that a "+", "#", or "-" in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains to the package regardless of RoHS status. PACKAGE TYPE PACKAGE CODE OUTLINE NO. LAND PATTERN NO. 10 TDFN-EP T1033+1 21-0137 90-0003 9 WLP W91G1+1 21-0755 Refer to Application Note 1891 Maxim Integrated 46 MAX17047/MAX17050 1-Cell Fuel Gauge with ModelGauge m3 Revision History REVISION NUMBER REVISION DATE PAGES CHANGED 0 9/11 Initial release 1 12/11 Added MAX17050 and added multicell application circuit information, updated schematics, Ordering Information, layout guideline, and Thermistor Sharing Circuit section 2 4/12 Corrected error on TDFN layout diagram in Figure 8 and corrected error of hard-coded bits of the LearnCFG register 14, 25, 43 3 8/12 Corrected error with FullSOCThr register formatting in Figure 25; corrected error with TOFF register formatting in Figure 62; added clarification that ALRTp bit must equal 0 to enable fast detection of cell removal 20, 30, 34, 42 4 12/14 Updated Figure 6 5 4/15 Updated the Fuel-Gauge Learning and Age Support and LearnCFG Register (28h) sections and Figure 33 6 3/16 Corrected WLP package outline number 46 7 11/16 Updated front page title and applications 1 DESCRIPTION -- 1, 7, 8, 11-41, 43, 45 12 11, 12, 25, 26 For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim Integrated's website at www.maximintegrated.com. Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits) shown in the Electrical Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance. Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc. (c) 2016 Maxim Integrated Products, Inc. 47