CARLINGSWITCH V-Series CONTURA II & III CONTURA X CONTURA XI The V-Series CONTURA rocker switches offer countless unique options including choices for ratings, colors, illuminations and symbols. These switches feature removable actuators in a choice of actuator styles and colors, are available in single or double pole configurations, and can be illuminated with either square or bar shaped lenses. An optional plug-in terminal connector enables pre- wiring of wire harness. All CONTURA switches, with sealed front panel components, are certified to IP66 and IP68, signifying complete protection against dust and prolonged spray and submersion under pressure, and are recognized to UL1500 - Ignition Protection for Marine Products. These switches are vibration, shock, thermo- shock, moisture and salt spray resistant. The CONTURA II and III actuators are available with optional soft-touch surfaces, optional lock-on terminal connector, and actuator removal tools. The CONTURA X and XI versions are available with one-piece bar lenses, or square lenses in either one or two part construction with back-lit legends, for increased durability of lens symbols. In addition, the CONTURA X and XI actuators also fit on the CONTURA II and CONTURA III base. Thus, actuators and square lenses may be purchased and stocked separately from the base assembly. The CONTURA X and XI versions include a raised bracket/bezel which helps prevent inadvertent actuation of the rocker. A-25-15 CONTURA Rocker Switches Specifications * Certifications*: UL, CSA, VDE, DEMKO, SEMKO, NEMKO, FIMKO, BEAB * Dielectric Strength: 2,000 V RMS opposite polarity; 4,000 V RMS between live parts & operator accessible surface. * Insulation Resistance: 50 Megohms * Function: SPST, DPST, SPDT, DPDT, SP8T. other circuits available, consult factory. * Operation: Two & three positions - maintained & momentary * Lighted: incandescent rated 10,000 hours; Neon rated 25,000 hours; LED rated 100,000 hours 1/2 life (LED is internally ballasted for voltages to 24VDC. * Seals: available with internal seal & optional external gasket panel seal. * Mounting: Snap-in mounting with flexible mounting wings suitable for panel thickness ranges of 0.30 tp 0.187 (0.76mm to 4.75 mm). Mounting hole dimensions are 1.450 by 0.830 (36.83 x 21.08mm). Base Material: Polyester * Actuator Material: CONTURA II and III: Underlay/Lens: Polycarbonate Hard overlay: Type 66 Nylon Soft overlay: Thermoplastic elastomer CONTURA X and XI: Nylon Lens Material: Polycarbonate * Bracket/Bezel Material: Type 66 Nylon * Temperature Ratings: -40C to 85C CONTURA switches are designed and tested in accordance with requirements of specification MILSTD 202F as follows: *Vibration: Method 204D, Test Condition A 0.06 DA or 10Gs. 10-500 Hz. Tested with VCH connector. Test criteria - No loss of circuit during test and pre and post test contact resistance. *Shock: Method 213B, Test Condition K@ 30 Gs. Tested with VCH connector. Test criteria - No loss of circuit during test and pre and post test contact resistance. *Salt Spray: Method 101D, Test Cond. A, 48 Hrs. Sealed Version only. *Thermal Shock: Method 107F, Test Cond. A, -55 to + 85C. Test Criteria - pre and post contact resistance. Moisture Resistance: Method 106E. Test criteria - pre and post test contact resistance. * Due to ongoing technological advances, consult factory far certification specifics. ObF MB 1920506 0001225 0b4 mw Carlingswitch,Inc. (860) 793-9281 Carlingswitch, LTD. Int + 44 1392-364422 Carlingswitch Asia-Pacific, LTD. Int + 852-2737-2277CARLINGSWITCH CONTURA Rocker Switches Dimensional Specifications: in. [mm] CONTURA II STYLE SHOWN WITH SQUARE LENS r 1.933[49.09] UL -505[12.83] 1,079[27.40] 2506.35] 1.550[39.37] 031.78] -390{9.90] -960[24.38] BASE W/BARRIERS 2.029[51.53} SWITCH SHOWN WITH VCH CONNECTOR CONTURA Ill STYLE SHOWN WITH LOCKING ROCKER 583[14.80] RELEASE MOTION re .080[2.03] + 1.479[37.57} | | -820[20.82] BASE W/O BARRIERS -960[24.38] QO mM = @ on &~A BOTTOM VIEW TERMINAL ARRANGEMENT D ObF M@ 1920506 OO0lecb TTO x= 6 Carlingswitch,Inc. (860) 793-9281 Carlingswitch, LTD. Int + 44 1392-364422 Carlingswitch Asia-Pacific, LTD. Int + 852-2737-2277CARLINGSWITCH CONTURA Rocker Switches Circuit Diagrams circuit | CIRCUIT DIAGRAM circuit; CIRCUIT DIAGRAM circuit | CIRCUIT DIAGRAM circuit | CIRCUIT DIAGRAM LP 819 Lp 661818 illo: oO 6 Of O c |jor/ A/o L Or FO ) 9 9 9 9 9 9 9 T T I { t f I T [ I | I [ I 2 2 2 5 2 5 | 3 i | 3 | i) Ft Ff | fF 4 ot 3 ott 8 of 6 4 o TL 6 2 11I0\*4: O 7 orf Oo pd jios/ fo H |Jov7: Wo 9 9 9 9 9 9 9 9 T I I I I I ] T I I | { | | 2 2 2 2 5 | 3 l || 3 | #4 F, , fF ot 6 of o of ae oo fe 3 |lOv/: Oo 8 ||OWlW: O F |lOv/ w/O ec ||joW: WoO 9 9 ) 9 9 9 9 ; 9 I I T I I I I T I T | | J | 2 2 2 5 2 5 je 3 8, 134 8 , oh = rr ers ob ba Be Su a }lo \ O ajlo\l: fo J oy fo mM |IOM-A' WO 9 9 9 9 9 9 9 9 I T T T T T ] I I | I ] T T 1 2 2 5 2 5 5 je _ 3 4 134 8 134 4 og 6 an -, po oo be Lo oto } ' ' i! ' ' 5 110% O B |lO\-k: \4O K Of fo E |\low } DESIGNATES TWO POSITION CONNECTION ____| DESIGNATES EXTERNAL JUMPER PROVIDED BY CUSTOMER D OBF Mf 1920506 0001228 473 x= = _______ 8 Carlingswitch,Inc. (860) 793-9281 Carlingswitch, LTD. Int + 44 1392-364422 Carlingswitch Asia-Pacific, LTD. Int + 852-2737-2277CARLINGSWITCH Lamp Circuits CONTURA Rocker Switches cna | CIRCUIT DIAGRAM taut, | CIRCUIT DIAGRAM dat, | CIRCUIT DIAGRAM tai; | CIRCUIT DIAGRAM +8 +8 4643-6 36 Aft F/6 L/g ISPECIAL : #3 T 7 43 48 +3 +3 -6 L | 1 t | B/2 G/7 M/R ISPECIAL ? ; #4 T T -7 -7 3 ie cis @ HZ | |@ , @ N/T T T 7 -7 i148 fs +6 D/4 } 6 J/8 b e P/V q T -7 7 +1 18 +8 +6 +3 +6 td) E/5 @ KAW 6 : 6 ISPECIAL #1 T T t , 7 (-)7 -7 SYMBOL LEGEND SYM DEFINITION DESIGNATES TERMINALS AND CONTACTS OTHER CIRCUITS AVAILABLE. oO DESIGNATES LAMP LOCATION CONSULT FACTORY. Carlingswitch,Inc. (860) 793-9281* Carlingswitch, LTD. Int + 44 1392-364422 * Carlingswitch Asia-Pacific, LTD. Int + 852-2737-2277 D ObF MM 1920506 0001225 70T a 9CARLINGSWITCH CONTURA II & III Rocker Switches B 6 0 B - T | L L LT 1 SERIES 5 ILLUMINATION & SWITCH SEALING Lamp #1 located above terminals 1 & 4 end of switch. v Lamp #2 located above terminals 3 & 6 end of switch. 2 CIRCUIT Positive (+) and negative (-) symbols apply to LED lamps only. Terminal Connections as viewed from bottom of switch: ACTUATOR LENS LAMP 8- -7 POSITION WHEN WIRED TO 5 SEALED UNSEALED LAMPS ILLUMINATED TERMINALS 3. 6 Ss 0 None SP - single pole - uses terminals 1, 2 & 3. A 1 #1 Independent 8+ DP - double pole uses terminals 1, 2, 3, 4,5 & 6. B 2 #1 Down 3+ 7 Terminals 7 & 8 for lamp circuit only. Cc 3 #2 Up 3+ 7- _. D 4 #1 Down 34+ = 7- Position 3 GONNECTED i &2 and #2 Down uo SP DP 5&6 TERMINALS 4&5 x 5 re ue Oe ; a ON | NONE : OFF F 6 #1 Independent 8+ 7- (ON) NONE OFF and #2U. 34 6 3 C ON NONE (OFF) G 7 fl olga ae 4D ON NONE ON ndependent 8+ 7- 5 F ON NONE (ON) and #2 Up a+ 7 6 J ON OFF ON. H Z #2 Independent 8+ 7- 7 =K ON OFF (ON) Selections for Single Pole Switches Only: 8 L (ON) OFF (ON) J 8 #1 Down 3+ 8- and #2 Independent 6+ 7- wee cmc 2&35&4 5&4 K WwW #1 Independent 8+ 7- G* 2&3.5&6 2& 3 OFF and #2 Independent 6+ 7- Me (2&3,5&6) 2&3 OFF Selections for Double Pole Switches Only: E* 5&6 5&3 5&1 L 9 #1 Down 3+ 6 M R #2 Up 3+ 6- * Jumper between terminals 2 & 5 for circuits H, G,& M to N Tp #1 Down 34 6- be specified in selection 4. External jumper between and #2 Down 14 4 terminals 2 & 4 for circuit E are to be provided by customer. P Vv #1 Up leo 4 Circuit E may be used for SP OFF-ON-ON circuit. Special and#2 U. 34 & circuits H, M and E not available with ratings 5 through 9. P 3 RATING 6, 7 LAMP Selection 6: above terminals 1 & 4 4 110A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP Selection 7: above terminals 3 & 6 5 ne Agen Histings IBA 125 VAC 1/2 HP USE SAME CODING FOR BOTH SELECTIONS UL Recognized, CSA Certified 0- NO LAMP THIS LOCATION 6* 15A 125VAC 1/2 HP, 12(2)A 125 VAC p T85 NEON INCANDESCENT 1-125VAC 4- 3V * 7 15A 125VAC 1/2 HP, 12(6)A 125 VAC T85 2-250VAC 5- 6V 8* 10A 250VAC, 15A 125VAC, 1/2 HP 125-250 VAC, 12(2)A 250 VAC p T85 gi 9* 10A 250VAC, 15A 125VAC, 1/2 HP 125-250 VAC, 8 - 24V 12(6)A 250 VAC T85 B 15A 24V LED SUPERBRIGHT SUPERBRIGHT C 204 18V RED AMBER GREEN RED D 90A 12V 2VDC A L F R G 20A GV 6VDC B M G Ss H 20A 3V 12VDC Cc N H T 24VDC D P J Vv * Ratings 6, 7, 8 & 9 are UL, CSA, VDE, DEMKO, SEMKO, NEMKO, FIMKO and BEAB certified. Rating 6 & 8 available 8 BRACKET COLOR, PANEL SEAL with circuits 2, 3, 5, 6, 7, 8, B, C, F, J, K, Lonly. Rating 8 is FLUSH BRACKET 1/2 HP, 250VAC only for circuits 2, 3, 5, 7, 8, K, L. Ratings 7 4 OF SEALS: (CONTURA IL. IID) & 9 available with circuits 1, 4, A, D. Ratings 6 & 7 only BRACKET = = available with lamp code 1 (125VAC neon). Ratings 8 & 9 only COLOR: available with lamp code 2 (250VAC neon). BLACK. B Cc . WHITE Ww Y 4 TERMINATION & JUMPER GRAY G H TERMINATION JUMPER 1 = .250TAB (QC) NO BARRIERS NO Mounting Hole Size: 1.450" x 0,830" A .250TAB (QC) WITH BARRIERS NO 36.83mm 21.08mm J .250TAB (QC) NO BARRIERS YES T2 TO 5 To mount multiple switches in single panel cut-out order optional NOTE: Base will not have terminal insulating barriers when interlocking mounting panels. connector and/or jumpers are used. Code J is optional for #OF GASKETS ACCEPTABLE PANEL THICKNESS RANGE circuits H, G and M. Customer may provide externally wired 0 .030" to .250 jumper to connect terminals 2 and 5. 76mm 4.76mm 1 .030" to .109" & .147" to .157" 16mm 2.77mm 3.73mm 3.98mm 10 Carlingswitch,Inc. (860) 793-9281 Carlingswitch, LTD. Int + 44 1392-364422 Carlingswitch Asia-Pacific, LTD. Int + 852-2737-2277 D ObF MI 1920506 0001230 4elCARLINGSWITCH A B T | J 9 ACTUATOR 0 - NO ACTUATOR (FURNISHED SEPARATELY) CONTURA II A CONTURA III c = a Actuator orientation above terminals: 10 LENS Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 0 - NO ACTUATOR Z-NO LENS Lens Location & Style: CLEAR WHITE AMBER GREEN RED BLUE: 1 6 B G M T 2 7 c wH nv U1) 3 8 pb Ss pv Ul} Square lens options available only for Contura II: 4 9 E K R wW a | 5 A F L s y (Il 11 ACTUATOR COLOR! AND TEXTURE 0-NO ACTUATOR SOFT SURFACE HARD SURFACE BLACK B Cc GRAY G H RED R s WHITE WwW Y 12 ACTUATOR LENS OR BODY LEGENDS" 00 - NO LEGEND THIS LOCATION/NO ACTUATOR ) | C 11. ON 145 oO oO F N OFF F 12. OFF 16 6 O 0 N F ON F 13 | 17. OO | 0 14 0 18 | QO FOR ADDITIONAL LEGEND OPTIONS & CODES, SEE PAGES 19 TO 25. NOTES: Shading indicates standard configurations. Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 Not available on Soft surface actuators. White imprinting is standard on black actuators. Black imprinting is standard on white, red and gray actuators. Custom colors are available. Consult factory. 18V bulbs recommended for 13.8 V applications for sharper illumination. For actuator only on CONTURA II with square lens; Orientation 1 & 2 only available with actuator A from selection 9; Orientation 3 & 4 only available with actuator B from selection 9. mo CONTURA II & III Rocker Switches 00 - 0 00 TL 13 LEGEND ORIENTATION! Field 13 must be 0 if legend code in selection 12 is 11 - 18. 0- NO LEGEND ORIENTATION OF ACTUATOR/LENS IN PANEL. ORIENTATION 1 Orientation 1 Orientation 2 Orientation 3 Orientation 4 moh on ORIENTATION 4 0: oo 2000 2000 AZCAC-100 * Additional orientations and locations for legends available, consult factory. 14 ACTUATOR LENS LEGENDS Field 14 must be 00 if legend code in selection 12 is 11 - 18. 00 - NO LEGEND THIS LOCATION/NO ACTUATOR Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14, FOR LEGEND OPTIONS & CODES, SEE PAGES 19 TO 25. V-Series Components: To order switch without actuator specify: V with code selections 2 through 8. (ex.) VIDABCOB-00000-000 To order actuator separately specify: VV with code A or C only for selection 9, and codes from above scheme for selections 10 through 14. (ex.) VVARBMA-100 Carlingswitch,Inc. (860) 793-9281 Carlingswitch, LTD. Int + 44 1392-364422 Carlingswitch Asia-Pacific, LTD. Int + 852-2737-2277 D ObF M@ 1920506 000123] 368 om