Overview SITOP power supplies SITOP UPS1600 / UPS1100 Manual SITOP UPS1600 10 A 6EP4134-3AB00-0AY0 6EP4134-3AB00-1AY0 6EP4134-3AB00-2AY0 SITOP UPS1600 20 A 6EP4136-3AB00-0AY0 6EP4136-3AB00-1AY0 6EP4136-3AB00-2AY0 SITOP UPS1600 40 A 6EP4137-3AB00-0AY0 6EP4137-3AB00-1AY0 6EP4137-3AB00-2AY0 SITOP UPS1100 Battery module 1.2 Ah 6EP4131-0GB00-0AY0 Battery module 2.5 Ah 6EP4132-0GB00-0AY0 Battery module 3.2 Ah 6EP4133-0GB00-0AY0 Battery module 5 Ah 6EP4133-0JB00-0AY0 Battery module 7 Ah 6EP4134-0GB00-0AY0 Battery module 12 Ah 6EP4135-0GB00-0AY0 04.2017 A5E37775406-8-76 Safety instructions 1 Description, device design, dimension drawing 2 Engineering and remote access 3 Troubleshooting 4 Mounting/removing 5 Mounting position, mounting clearances 6 Installation 7 Technical data 8 Safety, approvals, EMC 9 Environmental conditions 10 Environment 11 Service & Support 12 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Trademarks All names identified by (R) are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Process Industries and Drives Postfach 48 48 90026 NURNBERG GERMANY Document order number: A5E37775406 05/2017 Subject to change Copyright (c) Siemens AG 2017. All rights reserved Overview Description The DC-UPS modules augment the SITOP 24 V power supply units for uninterruptible rated currents up to 40 A from the UPS1100 battery modules based on maintenance-free lead or LiFePo batteries. SITOP UPS1600 with its integrated electronics automatically detects the battery type that it charges with the optimum temperature-controlled charging characteristic curve. The intelligent battery management monitors all relevant data, also for parallelconnected battery modules. The Ethernet/PROFINET interface is used to output the battery status and various actual values, such as voltage and current. Thanks to the integrated web server, remote diagnosis is also possible. The low profile SITOP UPS1600 DC-UPS module provides a dynamic overload behavior, for example, to switch on industrial PCs. The high charging current quickly restores the buffer readiness after a supply system failure. And for the deployment in stand-alone operation, the UPS can be activated from the battery for missing supply system voltage, e.g. to start the generators. The key benefits of the product include: Compact SITOP UPS1600 24 V/10 A, 20 A and 40 A DC-UPS modules with digital inputs/outputs, optional with USB or two Ethernet/PROFINET interfaces SITOP UPS1100 24 V/1.2 Ah, 2.5 Ah, 3.2 Ah, 7 Ah and 12 Ah battery modules with maintenance-free lead-gel batteries or 5 Ah with LiFePo batteries and integrated electronics Intelligent battery management with automatic detection of the battery modules, and selection of the optimum temperature-controlled charging characteristic; monitoring of readiness for operation, aging and charge status. All diagnostic data and alarm messages are available via USB and Ethernet/PROFINET High dynamic overload capability: 3-fold rated current for 30 ms and 1.5-fold rated current for 5 seconds per minute High charging currents Start from battery modules for missing supply system voltage SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 3 Overview OPC UA server with encrypted interface Remote monitoring via the integrated web server SITOP UPS Manager (free software download) supports the configuration and monitoring for PC-based systems Completely integrated in TIA: user-friendly engineering in SIMATIC STEP 7 and SIMATIC STEP 7 in the TIA Portal, S7 function blocks for integration in the user programs and WinCC faceplates Ordering data The following device options are available: SITOP UPS1600 uninterruptible power supply Type Order number Input 24 V DC 6EP4134-3AB00-0AY0 Output 24 V DC / 10 A Input 24 V DC 6EP4134-3AB00-1AY0 Output 24 V DC / 10 A With USB interface Input 24 V DC 6EP4134-3AB00-2AY0 Output 24 V DC / 10 A With PROFINET (PN) interface Input 24 V DC 6EP4136-3AB00-0AY0 Output 24 V DC / 20 A Input 24 V DC 6EP4136-3AB00-1AY0 Output 24 V DC / 20 A With USB interface Input 24 V DC 6EP4136-3AB00-2AY0 Output 24 V DC / 20 A With PROFINET (PN) interface Input 24 V DC, 6EP4137-3AB00-0AY0 Output 24 V DC / 40 A Input 24 V DC, 6EP4137-3AB00-1AY0 Output 24 V DC / 40 A With USB interface Input 24 V DC, 6EP4137-3AB00-2AY0 Output 24 V DC / 40 A With PROFINET (PN) interface SITOP UPS1600 / UPS1100 4 Manual, 04.2017, A5E37775406-8-76 Overview SITOP UPS1100 battery module Type Order number Battery module 1.2 Ah (lead) 6EP4131-0GB00-0AY0 Battery module 2.5 Ah (pure lead) 6EP4132-0GB00-0AY0 Battery module 3.2 Ah (lead) 6EP4133-0GB00-0AY0 Battery module 5 Ah (LiFePO4) 6EP4133-0JB00-0AY0 Battery module 7 Ah (lead) 6EP4134-0GB00-0AY0 Battery module 12 Ah (lead) 6EP4135-0GB00-0AY0 Accessory for SITOP UPS1600 Type Order number Device identification labels 20 mm x 7 mm, pastel turquoise 3RT1900-1SB20 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 5 Overview SITOP UPS1600 / UPS1100 6 Manual, 04.2017, A5E37775406-8-76 Table of contents Overview................................................................................................................................................. 3 1 Safety instructions ................................................................................................................................. 13 2 Description, device design, dimension drawing...................................................................................... 15 3 2.1 2.1.1 2.1.2 Device description...................................................................................................................15 SITOP UPS1600 .....................................................................................................................15 SITOP UPS1100 .....................................................................................................................18 2.2 2.2.1 2.2.1.1 2.2.1.2 2.2.1.3 2.2.1.4 2.2.2 2.2.2.1 Connections and terminal designation....................................................................................20 SITOP UPS1600 .....................................................................................................................20 Power terminals ......................................................................................................................20 Signal terminal ........................................................................................................................21 USB port .................................................................................................................................22 PROFINET/Ethernet connection .............................................................................................23 SITOP UPS1100 .....................................................................................................................24 Power terminals ......................................................................................................................24 2.3 2.3.1 2.3.1.1 2.3.1.2 2.3.1.3 2.3.2 2.3.2.1 Operator controls ....................................................................................................................25 SITOP UPS1600 .....................................................................................................................25 Rotary coding switch, switch-in threshold ...............................................................................25 Rotary coding switch, backup time .........................................................................................25 Jumper variants ......................................................................................................................26 SITOP UPS1100 .....................................................................................................................30 Buttons for battery replacement ..............................................................................................30 2.4 2.4.1 2.4.1.1 2.4.1.2 2.4.2 2.4.2.1 Operating displays and signaling ............................................................................................31 SITOP UPS1600 .....................................................................................................................31 LEDs .......................................................................................................................................31 Relay outputs ..........................................................................................................................34 SITOP UPS1100 .....................................................................................................................36 LEDs .......................................................................................................................................36 2.5 2.5.1 2.5.2 Block diagram .........................................................................................................................37 SITOP UPS1600 .....................................................................................................................37 SITOP UPS1100 .....................................................................................................................38 2.6 2.6.1 2.6.2 Dimensions and weight ...........................................................................................................39 SITOP UPS1600 .....................................................................................................................39 SITOP UPS1100 .....................................................................................................................42 Engineering and remote access ............................................................................................................ 47 3.1 General ...................................................................................................................................47 3.2 Overview of application examples ..........................................................................................48 3.3 3.3.1 3.3.2 3.3.3 SIMATIC STEP 7 in the TIA Portal .........................................................................................49 Introduction .............................................................................................................................49 Installing the Hardware Support Package (HSP) ...................................................................50 Installing the generic station description file (GSD) ................................................................52 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 7 Table of contents 3.3.4 3.3.5 3.3.6 3.3.7 3.3.8 3.3.9 3.3.10 3.3.11 Inserting SITOP UPS1600 into a project ............................................................................... 53 Assigning the SITOP UPS1600 to a controller ...................................................................... 54 Assigning a battery module SITOP UPS1100 to the basic device SITOP UPS1600 ............ 55 Parameterizing the UPS1600 ................................................................................................ 58 Loading the configuration (commissioning) ........................................................................... 63 Diagnostics ............................................................................................................................. 67 Firmware update .................................................................................................................... 69 Restore factory settings ......................................................................................................... 72 3.4 3.4.1 3.4.2 3.4.3 3.4.4 3.4.4.1 3.4.4.2 3.4.5 3.4.6 3.4.7 3.4.8 SIMATIC STEP 7 ................................................................................................................... 73 Introduction ............................................................................................................................ 73 Installing the generic station description file (GSD) ............................................................... 73 Inserting SITOP UPS1600 into a project ............................................................................... 74 Parameter assignment ........................................................................................................... 77 Parameters of the basic device and battery module.............................................................. 77 Parameterizing SITOP UPS1600........................................................................................... 77 Loading the configuration to the SITOP UPS1600 (commissioning) ..................................... 82 Diagnostics ............................................................................................................................. 85 Firmware update .................................................................................................................... 85 Restore factory settings ......................................................................................................... 89 3.5 3.5.1 3.5.2 3.5.2.1 Cyclic and acyclic data ........................................................................................................... 90 Input and output data ............................................................................................................. 90 Reading and writing data sets................................................................................................ 91 Data sets ................................................................................................................................ 93 3.6 3.6.1 3.6.2 3.6.3 3.6.4 3.6.5 3.6.6 3.6.7 3.6.7.1 3.6.7.2 3.6.8 3.6.9 3.6.10 3.6.11 SITOP UPS Manager ........................................................................................................... 109 Functions of the SITOP UPS Manager ................................................................................ 109 The user interface of the SITOP UPS Manager .................................................................. 110 Installation/uninstallation ...................................................................................................... 111 Options of establishing a connection to the SITOP UPS1600 ............................................. 113 Establishing a connection via Ethernet ................................................................................ 113 Establishing a connection via USB ...................................................................................... 118 Configuration in the SITOP UPS Manager .......................................................................... 118 General settings ................................................................................................................... 119 Configuring the SITOP UPS1600 ........................................................................................ 119 Behavior of the SITOP UPS Manager ................................................................................. 122 Display and visualization ...................................................................................................... 128 Determining the firmware version ........................................................................................ 132 Firmware update .................................................................................................................. 133 3.7 3.7.1 3.7.2 3.7.3 3.7.4 3.7.5 3.7.6 3.7.7 3.7.7.1 3.7.7.2 3.7.7.3 3.7.7.4 3.7.8 Web server ........................................................................................................................... 135 Accessing the web server .................................................................................................... 135 The web server user interface ............................................................................................. 138 Functions of the web server ................................................................................................. 139 Determining the firmware version ........................................................................................ 140 Firmware update with web server ........................................................................................ 140 Loading the configuration ..................................................................................................... 141 Diagnostics ........................................................................................................................... 141 Alarm monitoring .................................................................................................................. 141 View the data of the SITOP UPS1600 (basic device).......................................................... 143 Viewing the energy storage data ......................................................................................... 144 Online functions ................................................................................................................... 145 HW configuration.................................................................................................................. 146 SITOP UPS1600 / UPS1100 8 Manual, 04.2017, A5E37775406-8-76 Table of contents 4 3.7.8.1 3.7.8.2 3.7.8.3 3.7.8.4 3.7.8.5 3.7.8.6 3.7.8.7 3.7.8.8 General .................................................................................................................................146 Web server ............................................................................................................................148 OPC UA server .....................................................................................................................149 NTP client .............................................................................................................................150 Improved PN security............................................................................................................151 User administration ...............................................................................................................151 Device configuration .............................................................................................................153 Load / Save ...........................................................................................................................157 3.8 3.8.1 3.8.2 3.8.3 3.8.4 3.8.5 3.8.5.1 3.8.5.2 3.8.5.3 3.8.6 3.8.6.1 3.8.6.2 3.8.6.3 3.8.6.4 3.8.6.5 3.8.6.6 3.8.6.7 3.8.6.8 3.8.6.9 3.8.6.10 3.8.6.11 3.8.6.12 3.8.6.13 3.8.6.14 3.8.6.15 3.8.6.16 3.8.6.17 3.8.6.18 3.8.6.19 3.8.6.20 3.8.6.21 3.8.6.22 3.8.6.23 3.8.6.24 3.8.7 3.8.8 OPC UA server .....................................................................................................................158 Introduction ...........................................................................................................................158 Preconditions ........................................................................................................................158 Activating the OPC UA server via the SITOP UPS1600 web server ....................................159 Establishing a connection to the OPC UA server of the SITOP UPS1600 ...........................160 Working with the OPC UA client ...........................................................................................164 Displaying SITOP UPS1600 parameters ..............................................................................164 Changing the value of a node ...............................................................................................165 Calling a method ...................................................................................................................167 SITOP UPS1600 parameters in the OPC UA client .............................................................168 Introduction ...........................................................................................................................168 ActualBatteryState ................................................................................................................168 ActualBufferState ..................................................................................................................169 ActualChargingState .............................................................................................................169 ActualState ............................................................................................................................169 ActualUpdateState ................................................................................................................170 Alarm .....................................................................................................................................170 Battery ...................................................................................................................................172 Buffering ................................................................................................................................172 Charging ...............................................................................................................................173 General .................................................................................................................................173 Hardware ..............................................................................................................................173 Identification ..........................................................................................................................174 Lock.......................................................................................................................................174 MethodSet .............................................................................................................................174 Network .................................................................................................................................175 NTP .......................................................................................................................................175 OPC UA ................................................................................................................................176 ParameterSet ........................................................................................................................176 PROFINET ............................................................................................................................176 SubDevices ...........................................................................................................................176 UserManagement .................................................................................................................179 Web server ............................................................................................................................180 Additional ..............................................................................................................................180 OPC UA performance ...........................................................................................................181 Recommissioning after a basic device has been replaced - or after restoring the factory settings ......................................................................................................................181 Troubleshooting .................................................................................................................................. 183 4.1 Hardware fault .......................................................................................................................186 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 9 Table of contents 5 6 7 8 Mounting/removing ..............................................................................................................................187 5.1 5.1.1 5.1.2 5.1.3 SITOP UPS1600 .................................................................................................................. 187 Signal connector .................................................................................................................. 188 USB connector ..................................................................................................................... 189 PROFINET/Ethernet connector ........................................................................................... 190 5.2 SITOP UPS1100 .................................................................................................................. 191 Mounting position, mounting clearances ...............................................................................................193 6.1 6.1.1 6.1.2 6.1.2.1 6.1.2.2 6.1.2.3 SITOP UPS1600 .................................................................................................................. 193 Standard mounting position ................................................................................................. 193 Other mounting positions ..................................................................................................... 195 6EP4134-3AB00-... .............................................................................................................. 195 6EP4136-3AB00-... .............................................................................................................. 197 6EP4137-3AB00-... .............................................................................................................. 199 6.2 6.2.1 6.2.2 SITOP UPS1100 .................................................................................................................. 201 Standard mounting position ................................................................................................. 201 Other mounting positions ..................................................................................................... 201 6.3 Altitude derating ................................................................................................................... 202 Installation ...........................................................................................................................................203 7.1 Connecting the SITOP UPS1600 at its input ....................................................................... 205 7.2 Connecting the SITOP UPS1600 at its output ..................................................................... 205 7.3 Connecting the BAT SITOP UPS1600 ................................................................................ 206 7.4 USB interface ....................................................................................................................... 206 7.5 PROFINET/Ethernet connection .......................................................................................... 206 7.6 SITOP UPS1100 connections.............................................................................................. 207 7.7 7.7.1 7.7.2 Maintenance......................................................................................................................... 208 Battery .................................................................................................................................. 208 Battery replacement ............................................................................................................. 208 Technical data .....................................................................................................................................211 8.1 8.1.1 8.1.2 Input data ............................................................................................................................. 211 SITOP UPS1600 .................................................................................................................. 211 SITOP UPS1100 .................................................................................................................. 212 8.2 8.2.1 8.2.2 Output data .......................................................................................................................... 213 SITOP UPS1600 .................................................................................................................. 213 SITOP UPS1100 .................................................................................................................. 214 8.3 Backup times........................................................................................................................ 215 8.4 Efficiency .............................................................................................................................. 215 8.5 Protection and monitoring .................................................................................................... 216 8.6 MTBF ................................................................................................................................... 216 8.7 8.7.1 8.7.2 Mechanical system .............................................................................................................. 217 SITOP UPS1600 .................................................................................................................. 217 SITOP UPS1100 .................................................................................................................. 218 SITOP UPS1600 / UPS1100 10 Manual, 04.2017, A5E37775406-8-76 Table of contents 8.8 9 Dimension drawing ...............................................................................................................220 Safety, approvals, EMC....................................................................................................................... 221 9.1 Safety ....................................................................................................................................221 9.2 Test voltage ..........................................................................................................................222 9.3 Approvals ..............................................................................................................................223 9.4 EMC ......................................................................................................................................223 10 Environmental conditions .................................................................................................................... 225 11 Environment........................................................................................................................................ 229 12 Service & Support ............................................................................................................................... 231 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 11 Table of contents SITOP UPS1600 / UPS1100 12 Manual, 04.2017, A5E37775406-8-76 Safety instructions 1 WARNING Correct handling of the devices When operating electrical devices, it is inevitable that certain components will carry dangerous voltages. Therefore, failure to handle the units properly can result in death or serious physical injury as well as extensive property damage. Only appropriately qualified personnel may work on or in the vicinity of this equipment. Perfect, safe, and reliable operation of this equipment is dependent on proper transportation, storage, installation and mounting. Before installation or maintenance work can begin, the system's main switch must be switched off and measures taken to prevent it being switched on again. If this instruction is not observed, touching live parts can result in death or serious injury. Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines, and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement - and continuously maintain - a holistic, state-of-the-art industrial security concept. Siemens' products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks. Systems, machines and components should only be connected to the enterprise network or the internet if and to the extent necessary and with appropriate security measures (e.g. use of firewalls and network segmentation) in place. Additionally, Siemens' guidance on appropriate security measures should be taken into account. For more information about industrial security, please visit: http://www.siemens.com/industrialsecurity. Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends to apply product updates as soon as available and to always use the latest product versions. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer's exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under http://www.siemens.com/industrialsecurity. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 13 Safety instructions SITOP UPS1600 / UPS1100 14 Manual, 04.2017, A5E37775406-8-76 Description, device design, dimension drawing 2.1 Device description 2.1.1 SITOP UPS1600 2 The SITOP UPS1600 10 A, 20 A and 40 A are built-in devices of the SITOP series for mounting on TH35-15/7.5 standard mounting rails (EN 60715). When installing the SITOP UPS1600 devices and SITOP UPS1100 battery modules, the relevant DIN/VDE regulations or country-specific regulations (e.g. VDE 0510 Teil 2 / EN 50272-2) must be carefully complied with. See Section Installation (Page 203) In combination with the SITOP UPS1100 battery modules, they are used to buffer the load current from the 24 V load power supplies of the SITOP series. With their high dynamic overload capability up to the 300 % rated current for 30 ms or up to the 150 % rated current for 5 seconds per minute, they are suitable for applications with programmable logic controllers (PLCs) and industrial PCs, because they permit high switchon currents even in buffer operation. The input of the SITOP UPS1600 DC-UPS module must be connected with the output of the supplying 24 V DC power supply unit. The UPS1100 battery module is connected to the BAT terminals. The loads to be buffered are supplied via the output of the SITOP UPS1600 DCUPS module with the voltage connected at the input. The Energy Storage Link is new. This is an additional two-wire connection between the SITOP UPS1600 base device and the coded SITOP UPS1100 battery modules. Furthermore, the base device detects and manages as many as six battery modules and selects the optimum, temperature-controlled charging characteristic curve. The latter provides the basis for the long service life of the battery modules. The Energy Storage Link also monitors the operational readiness as well as the supply cables (wire breakage) and the charge state (voltage, current) of the rechargeable batteries. The connection to the SITOP UPS1100 battery module is checked every 20 seconds (for voltage, reverse polarity protection). A test with a defined load of the lead or LiFePo batteries is also performed automatically every four hours (basic setting). Battery modules of other type series and manufacturers can also be used, although with limited diagnostic functions, such as the display of the charging current or the end-of-charge voltage and without the possibility of temperature-controlled charging. In the event of failure of the 24 V DC supply voltage or voltage dip below the set switch-in threshold, the loads are supplied by switching over to the battery module. Buffering is realized until the line supply returns or until the buffer time, set using the rotary coding switch, has expired. If the buffer time has been set to MAX, then shutdown is realized when the exhaustive discharge threshold is reached. Using the output voltage interrupt function you can select as to whether the output voltage is interrupted once the set buffer time expires if, in the meantime, the input voltage returns (status when the device is delivered: the output voltage is not interrupted). For devices SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 15 Description, device design, dimension drawing 2.1 Device description without interface, the interruption lasts 5 s. For devices with interface, the interruption duration can be adjusted. For devices with software release up to V2.0.1, this function is only available for devices with interface, as the output voltage is only interrupted after a shutdown signal is received. For software version > V2.0.1, the interruption of the output voltage is independent of receiving a shutdown signal. For the "Maximum buffer time" setting, the output voltage is only interrupted by the UPS Manager. In this case, the rotary coding switch "Connection threshold" must be set to REN. Rotary switches can be used to set the battery module switch-in threshold and the buffer time. The charging current for the battery modules is set automatically, and can be changed using the interface (only for types -1AY0 and -2AY0), as well as via the signal connector. Eight LEDs, two potential-free changeover contacts and one floating NO contact indicate the SITOP UPS1600 status. The USB interface (only -1AY0) or PROFINET/Ethernet interface (only -2AY0) handles the communication to the PC/controllers. For details, see Sections Connections and terminal designation (Page 20) and Operator controls (Page 25). Operating data and diagnostic data can be transferred using two integrated Industrial Ethernet/PROFINET ports and visualized or further processed externally as an alternative to the proven USB connection. An integrated web server allows authorized users to export relevant data remotely via a web browser without requiring any additional software to be installed on the remote system. When delivered, the web server is not active (applies from version V2.1 and higher). Using the two rotary coding switches, the web server can be activated, and a temporary Internet address assigned, see SITOP UPS1600 (Page 25). The free-of-charge SITOP UPS Manager, which runs on Windows XP and Windows 7 systems (32 and 64 bit), allows full access. This allows the overall DC-UPS installation to be configured and monitored easily using a PC. The software tool provides many possibilities for the visualization of operating and diagnostic information, such as in the form of alarm lists or easily understandable trend diagrams which, for example, provide a view of the chronological change of the charging current or load current of the DC-UPS at a glance. The SITOP UPS1600 is fully integrated in Totally Integrated Automation (TIA), the Siemens open system architecture for integrated automation solutions. The engineering is performed in the TIA Portal and reduces to just a few clicks for the user. The UPS modules can be selected directly in the hardware catalog and transferred into the graphic network representation. For applications without network connection, the SITOP UPS1600 is available in the variants with USB interface or digital inputs/outputs. For stand-alone operation, the DC-UPS can be activated without input voltage from the battery, for example, to start a generator via a directly supplied controller. (see Chapter Jumper variants (Page 26)) SITOP UPS1600 / UPS1100 16 Manual, 04.2017, A5E37775406-8-76 Description, device design, dimension drawing 2.1 Device description DC input X1 DC output X1 BAT X1 Signal connector X2 PROFINET (Ethernet) interface X3 (only for ... - 2AY0) USB interface X3 (only for ... - 1AY0) Rotary coding switch, switch-in threshold Rotary coding switch, buffer time Signaling (LEDs) DIN rail slider Convection Clearance above/below Figure 2-1 SITOP UPS1600 design (example 6EP4136-3AB00-2AY0) SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 17 Description, device design, dimension drawing 2.1 Device description 2.1.2 SITOP UPS1100 The SITOP UPS1100 battery modules consist of a battery holder with two maintenance-free, closed lead or LiFePO batteries with terminals for the connection cables to the SITOP UPS1600 uninterruptible power supply. The UPS1100 contains a printed-circuit board for monitoring the battery functions and the communication with the SITOP UPS1600. A green LED lights continually to indicate that there is a communication connection to the SITOP UPS1600. The LED flashes when the batteries are being replaced or for faults and alarms. Note Battery module UPS1100 5 Ah with LiFePo batteries can only be used in conjunction with UPS1600 from software version V2.1. Up to 6 SITOP UPS1100 of the same type can be connected in parallel with a SITOP UPS1600. When replacing a battery, see Chapter Battery replacement (Page 208). DC input X1 Signal terminal X2 Fuses F1/F2 (F2 only for 7 Ah and 12 Ah) Signaling (LED) Mounting rail holder (not for the 7 Ah and 12 Ah versions) Natural convection Clearance above Figure 2-2 SITOP UPS1100 design (example 6EP4133-0GB00-0AY0) SITOP UPS1600 / UPS1100 18 Manual, 04.2017, A5E37775406-8-76 Description, device design, dimension drawing 2.1 Device description Note For the UPS1100, clearance is required above it in order to open the cover. Clearance below is not required for thermal reasons - however, space is required to feed in the cable. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 19 Description, device design, dimension drawing 2.2 Connections and terminal designation 2.2 Connections and terminal designation 2.2.1 SITOP UPS1600 2.2.1.1 Power terminals The input terminals can be used to establish the connection to the supply voltage. The output terminals are used to connect to the supplied loads. Cables must be used that are suitable for at least 90 C (only for applications for UL508). The UPS1100 battery modules are connected via BAT . (see also Chapter Installation (Page 203)) Connections and terminal designations (see Figure 2-1 SITOP UPS1600 design (example 6EP4136-3AB00-2AY0) (Page 17)) DC input IN+, IN- One screw terminal each DC output OUT+, OUT- One screw terminal each BAT+, BAT- One screw terminal each Signal connector Connector with 14 screw terminals PROFINET (Ethernet) connection RJ45 plug-in contact (only for ...-2AY0) USB connection USB-B plug-in contact (only for...-1AY0) Figure 2-3 Terminal data SITOP UPS1600 10 A, 20 A SITOP UPS1600 / UPS1100 20 Manual, 04.2017, A5E37775406-8-76 Description, device design, dimension drawing 2.2 Connections and terminal designation Figure 2-4 2.2.1.2 Terminal data SITOP UPS1600 40 A Signal terminal Signal connector Wire jumper Figure 2-5 Signal connector Figure 2-6 Signal connector connection schematic SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 21 Description, device design, dimension drawing 2.2 Connections and terminal designation Pin Terminal designation Function 1 BAT. 24 V DC OK / BAT 2 - 3 OK REL1 (changeover contact): Energized state: Normal operation Quiescent state: Buffer mode or off 4 ALARM Ready for buffer operation / alarm 5 - 6 RDY TO BUFFER REL2 (changeover contact): Energized state: Buffer mode is possible Quiescent state: Not ready for buffering Cycle 0.25 Hz: Defective battery 7 BAT. > 85 % Battery > 85% 8 - REL3 (NO contact): Energized state: Buffering of the selected buffer time is possible, or charge state > 85 % 9 ON/OFF On/Off (buffer operation permitted/prevented) 10 - - 11 BAT. X2.1 Battery communication or charging current setting 12 BAT. X2.2 Battery supply or charging current setting 13 INTERRUPT Interrupt (interruption of the output voltage) 14 START Start from the battery Relay contact: Contact rating, max. AC 30 V/0.5 A; DC 60 V/0.3 A; DC 30 V/1 A The jumper (4a) (see Figure Signal connector (Page 21)) between pin 9 and 10 is necessary to operate the device in buffer mode. Delivery state: Jumper between pin 9 and 10 2.2.1.3 USB port Figure 2-7 USB port The USB interface (type B) fully conforms to the USB 2.0 standard (12 MBd). Strain relief (see Section USB connector (Page 189)) is implemented using a defined cable/connector (Y-Con USB - Yamaichi). SITOP UPS1600 / UPS1100 22 Manual, 04.2017, A5E37775406-8-76 Description, device design, dimension drawing 2.2 Connections and terminal designation 2.2.1.4 PROFINET/Ethernet connection Figure 2-8 PROFINET/Ethernet connection The Ethernet interface corresponds to the standard full duplex up to 100 Mbit/s electrical (100BASE-TX) according to IEEE 802.3.. Properties of the Ethernet interface: Transfer rate 10/100 Mbit/s Two RJ45 sockets, i.e. integrated switch, for RJ45 connector Cable type 100Base-TX (CAT5) Auto negotiation Auto crossover communication via TCP/IP and PROFINET The strain relief (see Section PROFINET/Ethernet connector (Page 190)) is implemented using a Siemens IE FastConnect RJ45. The physics of the Ethernet interface is implemented so that PROFINET IO according to standards IEC 61158 and IEC 61784-2 is possible. For PROFINET, conformance class B must be maintained as a minimum. The Ethernet/PROFINET interface permits: Configuration and monitoring using the SITOP UPS Manager Monitoring via the Web server Integration and communication of the DC-UPS with other automation components from Siemens and the open environment, e.g. IPC, PLC, HMI, OPC UA Firmware update of the device via UPS Manager, web server or STEP 7 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 23 Description, device design, dimension drawing 2.2 Connections and terminal designation 2.2.2 SITOP UPS1100 2.2.2.1 Power terminals Input terminals and signal terminal can be used to establish the connection to SITOP UPS1600. (also see Chapter Installation (Page 203)). Connections and terminal designations (see Figure 2-2 SITOP UPS1100 design (example 6EP41330GB00-0AY0) (Page 18)) DC input +, - One screw terminal each Signal terminal 1, 2 One screw terminal each Figure 2-9 Terminal data for 6EP4131-0GB00-0AY0, 6EP4132-0GB00-0AY0, 6EP4133-0GB00 and 6EP4133-0JB00-0AY0 Figure 2-10 Terminal data for 6EP4134-0GB00-0AY0 and 6EP4135-0GB00-0AY0 SITOP UPS1600 / UPS1100 24 Manual, 04.2017, A5E37775406-8-76 Description, device design, dimension drawing 2.3 Operator controls 2.3 Operator controls 2.3.1 SITOP UPS1600 2.3.1.1 Rotary coding switch, switch-in threshold The switch-in threshold can be set using the rotary coding switch on the device front between 21.0 V and 25.0 V (21 - 21.5 - 22 - 22.5 - 23 - 24 - 25 volt). The delivery state is 22.5 V For devices with an interface (...-1AY0, ...-2AY0), the coding switch has an additional REN position. If this is selected, the software settings (for the switch-in threshold and the backup time) apply rather than the hardware settings. In the switch position REN, the connection X2.13 (INTERRUPT - reset after buffer operation) of the signal terminal (see Section Signal terminal (Page 21)) has no effect. Figure 2-11 Rotary coding switch, switch-in threshold Note It is only permissible to operate the rotary switch using an insulated screwdriver. For notes on actuating the rotary coding switch (screwdriver, torque), see Figure 2-3 Terminal data SITOP UPS1600 10 A, 20 A (Page 20). 2.3.1.2 Rotary coding switch, backup time The buffer time is set using the rotary coding switch on the device front between 30 seconds and MAX in steps of 0.5 minute (30 s), 1 minute, 2 minutes, 5 minutes, 10 minutes, 20 minutes and MAX. The MAX setting means that buffering is realized for as long as possible. The device only shuts down when the battery has discharged down to the stop buffering voltage (factory setting, 18.5 V). Delivery state is MAX The rotary coding switch has an additional setting OFF (see following diagram). If this is selected and the additional threshold rotary coding switch is not set to REN, then buffering is deactivated. If the buffer time is to be set using the software (only for devices with an interface (...-1AY0, ...-2AY0)) (possible setting range, see Section Parameterizing SITOP UPS1600 (Page 77)), the rotary coding switch for the connection threshold must be set to REN (see Section Rotary coding switch, switch-in threshold (Page 25)). SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 25 Description, device design, dimension drawing 2.3 Operator controls Figure 2-12 Rotary coding switch, buffer time Note It is only permissible to operate the rotary switch using an insulated screwdriver. For notes on actuating the rotary coding switch (screwdriver, torque), see Figure 2-3 Terminal data SITOP UPS1600 10 A, 20 A (Page 20) 2.3.1.3 Jumper variants On/Off (pin 9) The wire jumper on the signal connector between pin 9 and pin 10 is used to enable/disable the buffer mode (see Figure 2-5 Signal connector (Page 21)). Buffer operation is only possible if the ON/OFF wire jumper is connected. The ON/OFF wire jumper has priority over the position of the switch-in threshold rotary coding switch. Delivery state: Wire jumper is connected between pin 9 and 10 As a consequence, buffer operation can be enabled or prevented using a floating contact (e.g. a contact in the plant or system). The contact is switched instead of the ON/OFF wire jumper. Note The contact in the switched-on state must have a resistance of < 10 Ohm, contact load must be a minimum of 15 V / 5 mA. Note The external circuit must meet the requirements relating to SELV circuits according to EN60950-1. SITOP UPS1600 / UPS1100 26 Manual, 04.2017, A5E37775406-8-76 Description, device design, dimension drawing 2.3 Operator controls Changes are also effective in the buffer mode. Table 2- 1 With interface (up to firmware release less than V1.20) Rotary coding switch, buffer time Rotary coding switch, connection threshold Wire jumper ON/OFF with respect to - OFF 21 - 25 Yes Buffering not permitted 0,5 - MAX 21 - 25 Yes Buffer mode permitted (buffer time corresponding to the settings or maximum buffer time) OFF, 0,5 - MAX 21 - 25 No Buffering not permitted OFF, 0,5 - MAX REN Not relevant Table 2- 2 Result The software settings apply With interface (from firmware release V1.20 up to V2.0.x) Rotary coding switch, buffer time Rotary coding switch, connection threshold Wire jumper ON/OFF with respect to - Result OFF 21 - 25 Yes Buffering not permitted 0,5 - MAX 21 - 25 Yes Buffer mode permitted (buffer time corresponding to the settings or maximum buffer time) OFF, 0,5 - MAX 21 - 25, REN No Buffering not permitted OFF, 0,5 - MAX REN Yes The software settings apply Table 2- 3 With interface (from firmware release V2.1) Rotary coding switch buffer time Rotary coding switch switch-in threshold Wire jumper ON/OFF with respect to - Result OFF 21 - 25 Yes Buffering not permitted 0,5 - MAX 21 - 25 No Buffering not permitted 0,5 - MAX 21 - 25 Yes Buffer mode permitted (buffer time corresponding to the settings or maximum buffer time) OFF, 0,5 - MAX 21 - 25 REN No Buffering not permitted SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 27 Description, device design, dimension drawing 2.3 Operator controls Rotary coding switch buffer time Rotary coding switch switch-in threshold Wire jumper ON/OFF with respect to - 0,5 - MAX REN Yes OFF REN Not relevant The web server can be activated, and a temporary Internet address assigned (precondition: IP address is 0.0.0.0 (when delivered)) Result Table 2- 4 Result The software settings apply Without interface Rotary coding switch, buffer time Rotary coding switch, connection threshold Wire jumper ON/OFF with respect to - OFF 21 - 25 Yes Buffering not permitted OFF 21 - 25 No Buffering not permitted 0,5 - MAX 21 - 25 Yes Buffer mode permitted (buffer time corresponding to the settings or maximum buffer time) 0,5 - MAX 21 - 25 No Buffering not permitted Interruption of the output voltage (pin 13) A wire jumper on the signal connector between pin 13 and pin 10 is used to enable/disable the interruption of the output voltage, after the set buffer time expires, for the parameterized time (default value 5 seconds) when the line supply returns during the buffer time. The default value can only be changed for devices with USB or Ethernet/PROFINET interface. To prevent data losses, PCs must be shut down in time before the buffer time ends. If the input voltage returns after the shutdown has already started, the SITOP UPS1600 terminates the buffer mode and transitions into normal operation. The PC will be shut down, however, it is not switched off. PCs, which do not have an on/off switch, can only be rebooted by switching off the power and switching on again. When the "Interrupt output voltage" jumper is inserted, the UPS generates this pulse. Start from the battery (pin 14) The start from the battery is initiated by connecting pin 14 to pin 10. This jumper must not provide a permanent connection, but must be controlled using a button. The input is designed so that a single lamp with a permissible supply voltage of between 12 and 30 V and 8 to 15 mA can be switched in series to the switching contact. If the button is actuated when the input voltage is not available, and if buffering is permitted, then the UPS goes into the buffer mode. The UPS1600 shuts down if, at the end of the selected buffer time, an input voltage is still not available. The SITOP UPS1600 starts in normal operation if the input voltage is available. SITOP UPS1600 / UPS1100 28 Manual, 04.2017, A5E37775406-8-76 Description, device design, dimension drawing 2.3 Operator controls This can occur if the UPS was remotely shut down via the interface. Note From UPS Manager Version V4.71.13 and UPS1600 Version V2.1.0, when starting from the battery, buffer operation is identified when powering up. After the set time "Shut down PC on power failure" the PC is correctly powered down and switched off. For earlier versions of the UPS Manager and the UPS1600 Version, when starting from the battery after the buffer time expires, the output of the UPS1600 is switched off without first having powered-down the PC. Charge current setting (pin 10 / 11 / 12) For uncoded batteries, the size of the charge current can be changed by placing jumpers between terminals X2.10 (-) and X2.11 or X2.12. These settings are only effective if the "Connection threshold" rotary coding switch is not set to REN. Table 2- 5 Charge current SITOP UPS1600 10 A SITOP UPS1600 20 A and 40 A Terminal X2.11 Terminal X2.12 0.3 A 0.8 A open open 0.8 A 1.75 A open connected with X2.10 Max. Max. connected with X2.10 open Remark The charge current can be automatically reduced if the charge current plus the load current at the UPS1600 results in an overload of the feeding power supply. The charge current can also be reduced if the ambient temperature of the UPS1600 is higher than 40 C - or if the input voltage at the UPS1600 is less than 24 V. Derating: 10 A: 3 A-->2 A 20 A: 4 A-->3 A 40 A: 5 A-->3 A SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 29 Description, device design, dimension drawing 2.3 Operator controls 2.3.2 SITOP UPS1100 2.3.2.1 Buttons for battery replacement For the SITOP UPS1100, below the cover there is a button for battery replacement, see Battery replacement (Page 208) Figure 2-13 Buttons for battery replacement SITOP UPS1600 / UPS1100 30 Manual, 04.2017, A5E37775406-8-76 Description, device design, dimension drawing 2.4 Operating displays and signaling 2.4 Operating displays and signaling 2.4.1 SITOP UPS1600 2.4.1.1 LEDs 6EP4134-3AB00- ... 6EP4136-3AB00- ... 6EP4137-3AB00- ... Status display * LED 1: Operating mode DC-UPS LED 2: Charge state LED 3: Buffer readiness LED 4: Battery test LED 5: for PROFINET-specific diagnostic displays LED 6: for PROFINET-specific diagnostic displays LED 7: Connection status Ethernet port 1 LED 8: Connection status Ethernet port 2 Remark LEDs 5 to 8 are only active for... -2AY0 LEDs Labeling, just the same as at the housing Description LED 1 O.K./BAT. Operating mode DC-UPS LED 2 BAT. > 85 % Charge state LED 3 ALARM Ready for buffering LED 4 BAT. FAULT Battery test LED 5 SF for PROFINET-specific diagnostic displays LED 6 RUN for PROFINET-specific diagnostic displays LED 7 P2 Connection status Ethernet port 1 LED 8 P1 Connection status Ethernet port 2 Figure 2-14 Operating displays Legend: LED off LED lights up 0.5/3 LED flashes in the interval: 0.5 s on - 3 s off SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 31 Description, device design, dimension drawing 2.4 Operating displays and signaling LED 1 (O.K./BAT) Signaling 6EP4134-3AB00- ... 6EP4136-3AB00- ... 6EP4137-3AB00- ... Off DC-UPS off Red DC-UPS defect (severe hardware fault) Flashing red (0.5/0.5) Firmware update Flashing red (1/1) Software corrupted Flashing yellow (0.5/0.5) Critical temperature identified, overtemperature or overvoltage at the input Flashing yellow (0.5/3) Buffer mode, output off Yellow Buffer mode, output on Flashing green (0.5/3) DC-UPS OK, output off Green DC-UPS OK, output on LED 2 (BAT>85 %) Signaling 6EP4134-3AB00- ... 6EP4136-3AB00- ... 6EP4137-3AB00- ... Flashing green (0.5/0.5) Firmware update Off Battery charge state <85 % Green Battery charge state >85 % The LED and the relay contact (see Chapter Relay outputs (Page 34)) have two meanings: 1. If no other settings have been made, then the LED lights up after reaching a charge state greater than 85 %. The LED goes dark if the charge state falls below 85 %. 2. If an expected buffer current and a buffer time are set under the hardware configuration, then the LEDs and the relay contact serve as an indicator when buffering is possible with the two parameters - or is no longer possible. Note From the instant in time when the SITOP UPS1600 is switched over into the buffer mode, for the evaluation, instead of the expected buffer current, the actually measured buffer current is used. As a consequence, the status of the LEDs and the relay can also change. SITOP UPS1600 / UPS1100 32 Manual, 04.2017, A5E37775406-8-76 Description, device design, dimension drawing 2.4 Operating displays and signaling LED 3 (alarm) Signaling 6EP4134-3AB00- ... 6EP4136-3AB00- ... 6EP4137-3AB00- ... Red Output off for 45 seconds because of overcurrent, overtemperature or buffer operation not possible Off Buffer operation possible LED 4 (battery/BAT.Fault) Signaling 6EP4134-3AB00- ... 6EP4136-3AB00- ... 6EP4137-3AB00- ... Off Battery O.K. or uncoded battery modules connected or buffer time rotary coding switch at position MAX Flashing yellow (0.5/0.5) Battery outside the permitted temperature range Red Battery defective Yellow Selected buffer time cannot be attained LED 5 and LED 6 (PROFINET LEDs) Signaling 6EP4134-3AB00-2AY0 6EP4136-3AB00-2AY0 6EP4137-3AB00-2AY0 LED 5 (SF) LED 6 (RUN) Off Off No connection to a PROFINET IO controller Off Flashing green (0.5/0.5) Configuration by the PROFINET IO controller Off Green Application started successfully, module O.K. Red Green Application started successfully, module not O.K. Flashing red (0,1/0,1) Green Application in progress, diagnosis can be called Flashing red (0.5/0.5) Flashing green (0.5/0.5) Self-test running (flashing alternately every 3 s) Flashing red (0.5/0.5) Off DCP requires device identification (LED flashes for 3 seconds) Flashing red (0.5/0.5) Flashing green (0.5/0.5) Firmware update LEDs 5 and 6 are active only for ... -2AY0. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 33 Description, device design, dimension drawing 2.4 Operating displays and signaling LED 7 (Ethernet LED / P2) Signaling 6EP4134-3AB00-2AY0 6EP4136-3AB00-2AY0 6EP4137-3AB00-2AY0 Off Device not connected with controller Green Device connected with controller, no activity Green/orange alternately Device connected with controller, send/receive data (RX/TX) LED 7 is active only for ... -2AY0 LED 8 (Ethernet LED / P1) Signaling 6EP4134-3AB00-2AY0 6EP4136-3AB00-2AY0 6EP4137-3AB00-2AY0 Off Device not connected with controller Green Device connected with controller, no activity Green/orange alternately Device connected with controller, send/receive data (RX/TX) LED 8 is active only for ... -2AY0 2.4.1.2 Relay outputs Figure 2-15 Signal connector connection schematic REL1 (changeover contact): Energized state: Normal operation (X2.2 - X2.3) Deenergized state: Buffer mode or off REL2 (changeover contact): Energized state: Buffer operation is possible (X2.5 - X2.6) Deenergized state: Not ready for buffering Cycle 0.25 Hz: Battery defective or different - or more than 6 battery modules connected - or the selected buffer time is not reached. REL3 (NO contact): Energized state: Buffering of the selected buffer time is possible, or charge state > 85 %. SITOP UPS1600 / UPS1100 34 Manual, 04.2017, A5E37775406-8-76 Description, device design, dimension drawing 2.4 Operating displays and signaling Contact rating: 30 V AC/0.5 A 60 V DC/0.3 A 30 V DC/1 A Note From the instant in time when the SITOP UPS1600 is switched over into the buffer mode, for the evaluation, instead of the expected buffer current, the actually measured buffer current is used. As a consequence, the status of the LEDs and the relay can also change. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 35 Description, device design, dimension drawing 2.4 Operating displays and signaling 2.4.2 SITOP UPS1100 2.4.2.1 LEDs 6EP4131-0GB00-0AY0 (1.2 Ah) 6EP4132-0GB00-0AY0 (2.5 Ah) 6EP4133-0GB00-0AY0 (3.2 Ah) 6EP4133-0JB00-0AY0 (5 Ah) 6EP4134-0GB00-0AY0 (7 Ah) 6EP4135-0GB00-0AY0 (12 Ah) Status display LED battery Figure 2-16 Table 2- 6 6EP4131-0GB00-0AY0 example LED battery Signaling 6EP4131-0GB00-0AY0 (1.2 Ah) 6EP4132-0GB00-0AY0 (2.5 Ah) 6EP4133-0GB00-0AY0 (3.2 Ah) 6EP4133-0JB00-0AY0 (5 Ah) 6EP4134-0GB00-0AY0 (7 Ah) 6EP4135-0GB00-0AY0 (12 Ah) Flashing green (0.5/0.5) Error or alarm, battery replacement initiated Off Battery off, no communication Green Battery OK SITOP UPS1600 / UPS1100 36 Manual, 04.2017, A5E37775406-8-76 Description, device design, dimension drawing 2.5 Block diagram 2.5 Block diagram 2.5.1 SITOP UPS1600 Figure 2-17 Block diagram SITOP UPS1600 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 37 Description, device design, dimension drawing 2.6 Dimensions and weight 2.5.2 SITOP UPS1100 Figure 2-18 Block diagram SITOP UPS1100 SITOP UPS1600 / UPS1100 38 Manual, 04.2017, A5E37775406-8-76 Description, device design, dimension drawing 2.6 Dimensions and weight 2.6 Dimensions and weight 2.6.1 SITOP UPS1600 Figure 2-19 6EP4134-3AB00-0AY0, 6EP4134-3AB00-1AY0, 6EP4136-3AB00-0AY0,6EP41363AB00-1AY0 dimensioned drawing Figure 2-20 6EP4134-3AB00-2AY0, 6EP4136-3AB00-2AY0 dimensioned drawing SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 39 Description, device design, dimension drawing 2.6 Dimensions and weight Figure 2-21 Dimension drawing 6EP4137-3AB00-0AY0, 6EP4137-3AB00-1AY0 Figure 2-22 Dimension drawing 6EP4137-3AB00-2AY0 SITOP UPS1600 / UPS1100 40 Manual, 04.2017, A5E37775406-8-76 Description, device design, dimension drawing 2.6 Dimensions and weight 6EP4134-3AB00-0AY0 6EP4134-3AB00-1AY0 6EP4134-3AB00-2AY0 Dimensions (W x H x D) in mm 50 x 138.7 x 125 50 x 138.7 x 125 50 x 138.7 x 125 Weight Approx. 0.38 kg Approx. 0.4 kg Approx. 0.45 kg 6EP4136-3AB00-0AY0 6EP4136-3AB00-1AY0 6EP4136-3AB00-2AY0 Dimensions (W x H x D) in mm 50 x 138.7 x 125 50 x 138.7 x 125 50 x 138.7 x 125 Weight Approx. 0.39 kg Approx. 0.41 kg Approx. 0.45 kg 6EP4137-3AB00-0AY0 6EP4137-3AB00-1AY0 6EP4137-3AB00-2AY0 Dimensions (W x H x D) in mm 70 x 138.7 x 150 70 x 138.7 x 150 70 x 138.7 x 150 Weight Approx. 0.65 kg Approx. 0.65 kg Approx. 0.7 kg SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 41 Description, device design, dimension drawing 2.6 Dimensions and weight 2.6.2 SITOP UPS1100 Figure 2-23 6EP4131-0GB00-0AY0 dimensioned drawing Figure 2-24 Dimension drawing 6EP4132-0GB00-0AY0 SITOP UPS1600 / UPS1100 42 Manual, 04.2017, A5E37775406-8-76 Description, device design, dimension drawing 2.6 Dimensions and weight Figure 2-25 6EP4133-0GB00-0AY0 dimensioned drawing Figure 2-26 Dimension drawing 6EP4133-0JB00-0AY0 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 43 Description, device design, dimension drawing 2.6 Dimensions and weight Figure 2-27 6EP4134-0GB00-0AY0 dimensioned drawing Figure 2-28 Dimension drawing 6EP4135-0GB00-0AY0 SITOP UPS1600 / UPS1100 44 Manual, 04.2017, A5E37775406-8-76 Description, device design, dimension drawing 2.6 Dimensions and weight 6EP4131-0GB00-0AY0 (1.2 Ah) 6EP4132-0GB00-0AY0 (2.5 Ah) 6EP4133-0GB00-0AY0 (3.2 Ah) Dimensions (W x H x D) in mm 89 x 130.3 x 106.7 265 x 115 x 76 190 x 169.3 x 78.7 Weight Approx. 1.9 kg Approx. 3.7 kg Approx. 3.8 kg 6EP4133-0JB00-0AY0 (5 Ah) 6EP4134-0GB00-0AY0 (7 Ah) 6EP4135-0GB00-0AY0 (12 Ah) Dimensions (W x H x D) in mm 189 x 185.5 x 112.7 186 x 186 x 110.3 253 x 186 x 110 Weight Approx. 3.4 kg Approx. 6.1 kg Approx. 9.8 kg SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 45 Description, device design, dimension drawing 2.6 Dimensions and weight SITOP UPS1600 / UPS1100 46 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.1 3 General This section describes the software tools offered by Siemens that are compatible with SITOP UPS1600 . The software tools are introduced with their functions, the associated requirements and the operation. The software products are: SIMATIC STEP 7 in the TIA Portal SIMATIC STEP 7 SITOP UPS Manager Web server OPC UA Functions of the individual software products SIMATIC STEP 7 in the TIA Portal The SITOP UPS1600 can be used with STEP 7 in the TIA portal from version 12 with service pack 1 (SP1). From SW version V2.2, STEP 7 can be used in the TIA Portal from version 13 with service pack 1. After SITOP UPS1600 has been saved in the hardware catalog of STEP 7 in the TIA Portal , it can be integrated in the project, parameterized and diagnosed. SIMATIC STEP 7 SITOP UPS1600 can be used with SIMATIC STEP 7 from Version 5.4. After SITOP UPS1600 has been integrated in the hardware catalog of STEP 7 it can be integrated in projects, parameterized and diagnosed. SITOP UPS Manager Using the SITOP UPS Manager , theSITOP UPS1600 can be parameterized. In addition, the protection of individual computers or computer networks can be determined by shutdown conditions after the failure of the supply voltage. Web server The web server is used to monitor the SITOP UPS1600. It operates independently of the UPS Manager and the PROFINET access. Note SIMATIC STEP 7 and the SITOP UPS Manager cannot simultaneously access the SITOP UPS1600. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 47 Engineering and remote access 3.2 Overview of application examples 3.2 Overview of application examples At our support web site you can find the following application example to parameterize the SITOP UPS1600 uninterruptible power supply: "SITOP UPS1600: Graphic blocks and STEP 7 communication blocks" to integrate SITOP UPS1600 into an automation system : (https://support.industry.siemens.com/cs/ww/en/view/78817848) SITOP UPS1600 / UPS1100 48 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal 3.3 SIMATIC STEP 7 in the TIA Portal 3.3.1 Introduction The uninterruptible power supply SITOP UPS1600 can be used with SIMATIC STEP 7 in the TIA Portal from Version 12 with service pack 1 (SP1). From SW version V2.2, STEP 7 can be used in the TIA Portal from Version 13 with service pack 1. In SIMATIC STEP 7 in the TIA Portal , the basic device SITOP UPS1600 and its battery modules SITOP UPS1100 can be integrated in projects, parameterized and diagnosed. Note If you wish to use SIMATIC STEP 7 V13 in the TIA Portal, then you must install the appropriate Hardware Support Package (HSP) or the appropriate generic station description file (GSD) in order to use the SITOP UPS1600 and the supplementary modules. This step is not required from SIMATIC STEP 7 V14 in the TIA Portal. Using SITOP UPS1600 with HSP is only possible from TIA Version V13; in TIA Version12, only using GSD. You can find additional information at Installing the Hardware Support Package (HSP) (Page 50) or Installing the generic station description file (GSD) (Page 52). Note TIA and SITOP UPS Manager cannot simultaneously access SITOP UPS1600. The service of the SITOP UPS Managers may not run while the system is accessed via TIA. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 49 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal 3.3.2 Installing the Hardware Support Package (HSP) Note SIMATIC STEP 7 V13 service pack 1 The following step is only relevant for SIMATIC STEP 7 V13 with service pack 1 in the TIA Portal. The HSP is available at our SITOP-homepage (http://www.siemens.com/sitop-ups1600) or directly at (https://support.industry.siemens.com/cs/ww/en/view/75854606). Procedure To install the Hardware Support Package, proceed as follows: 1. Start STEP 7 in the TIA Portal. 2. In the "Options" menu, click on "Support Packages". Dialog "Detailed information" opens. All Support Packages from the directory that you specified as storage location for Support Packages in the settings are listed in a table. 3. You have the following possibilities to install the Hardware Support Package: - If the Support Package is already present on your computer or on the supplied DVD, you can add it to the list from the "Add from the file system". - If you want to add a Support Package from the "Service & Support" page in the Internet, download it with "Load from the Internet". You can then add it to the file system. 4. Select the support package that you want to install. 5. Click on "Install", and follow the instructions of the installation program. During the installation you will be prompted to close all TIA Portal instances. 6. Close all TIA Portal instances and click on "Continue". 7. After the Support Package has been installed, the TIA Portal is reinitialized by clicking on "Restart". The installed devices are imported into the module catalog and can then be integrated in the project. You can find the SITOP UPS1600 in the hardware catalog under "Power Supplies\SITOP UPS\UPS1600". SITOP UPS1600 / UPS1100 50 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal Note You can find additional information on installing hardware support packages in the manual of your STEP 7 software. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 51 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal 3.3.3 Installing the generic station description file (GSD) Note SIMATIC STEP 7 V13 The following step is only relevant for SIMATIC STEP 7 V13 in the TIA Portal. The GSD is available at our SITOP-homepage (http://www.siemens.com/sitop-ups1600) or directly at (https://support.industry.siemens.com/cs/ww/en/view/75854605). Preconditions You know where the GSD file is saved. Procedure To install the generic station description file, proceed as follows: 1. Download the GSD file from the Internet. 2. Start SIMATIC STEP 7 V13 in the TIA Portal. 3. In the project view, click in the menu "Options" on "Install general station description file (GSD)" or "Manage general station description file (GSD)". The "Manage general station description file (GSD)" dialog is opened. 4. Select the source path under which you locally saved the GSD file that you downloaded. 5. Select the GSD file. 6. Click on "Install", and follow the instructions of the installation program. The installed devices are imported into the module catalog and can then be integrated in the project. You can find the UPS1600 in the hardware catalog at "Other field devices\PROFINET IO\I/O\Siemens AG\UPS1600". SITOP UPS1600 / UPS1100 52 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal 3.3.4 Inserting SITOP UPS1600 into a project To be able to use the SITOP UPS1600, you must assign it as IO device to an IO controller (SIMATIC S7 control). Further, SITOP UPS1600 can be equipped in the project with one or several SITOP UPS1100 battery modules. The main views used to configure the SITOP UPS1600 are the Network view and the Device view. Note Additional information on the Network view and Device view, as well as the Topology view is available in the manual for your STEP 7 software. Preconditions The hardware support package or the general station description file of the SITOP UPS1600 has been installed. STEP 7 in the TIA Portal has been opened, and a project with an IO controller (SIMATIC S7 control) has been created. Inserting SITOP UPS1600 from the hardware catalog 1. Open the network view. 2. Open the "Hardware catalog" task card. 3. If you use the SITOP UPS1600 with the hardware support package: In the "Catalog" palette, navigate to SITOP UPS1600 under Power Supplies\SITOP UPS\UPS1600. 4. If you use the SITOP UPS1600 with the generic station description file: In the "Catalog" palette, navigate to the SITOP UPS1600 under "Other devices\PROFINET IO\I/O\Siemens AG\UPS1600". SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 53 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal 5. Select the required SITOP UPS1600 using a mouse click. In the "Information" area you can see information about the selected SITOP UPS1600, and if necessary change the preselected version. 6. Drag the SITOP UPS1600 and drop it into the Network view. Alternatively, you can add the module to the Network view by double-clicking on the entry in the hardware catalog. You have now inserted the SITOP UPS1600 into the project. The rectangle displayed in the network view symbolizes the SITOP UPS1600. 3.3.5 Assigning the SITOP UPS1600 to a controller To be able to use the SITOP UPS1600 you must assign an IO controller as IO device. 1. Click in the network view on the blue lettering "Not assigned" at the left next to the symbol of the SITOP UPS1600. A menu opens with the available controllers. 2. Select a controller in the menu. SITOP UPS1600 / UPS1100 54 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal 3. Select the connection between the controller and SITOP UPS1600. 4. Make the required settings in the "Network data". 5. Double-click on SITOP UPS1600 to display it in the device view. 6. Select the PROFINET-interface. 7. Under "Ethernet addresses" in the inspector window enter the IP address of the SITOP UPS1600, which was already assigned in theTIA Portal. You have assigned a controller to the SITOP UPS1600. 3.3.6 Assigning a battery module SITOP UPS1100 to the basic device SITOP UPS1600 The basic functions of the uninterruptible power supply are available with all of the battery modules that are compatible with the SITOP UPS1600. The SITOP UPS1100 5 Ah LiFePo battery is first supported by the UPS1600 with SW version V2.1. Additional functions are available with the SITOP UPS1100 battery module: Automatic detection of the battery module rated values Automatic management of up to six battery modules Temperature-controlled charging Battery fast test Diagnostics using the SITOP UPS Manager and the web server SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 55 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal Using an example, in the following steps, it is shown how the SITOP UPS1600 is assigned a SITOP UPS1100 battery module. Note Only SITOP UPS1100 battery modules of the same type can be inserted into the slots of a SITOP UPS1600. The number of battery modules that can be configured is limited to six. The description is only applicable to devices that were linked to via the HSP. Preconditions STEP 7 in the TIA Portal has been opened and a project has been created. A SITOP UPS1600 has been integrated in the project. Procedure The procedure is only applicable for devices integrated via HSP. For GSD devices, values can be manually specified for a (third-party) battery module; however, it is not necessary to add a battery module to the configuration. 1. In the device view, select the SITOP UPS1600 basic device. 2. In the Hardware catalog , navigate to the SITOP UPS1100 battery module under Power Supplies\SITOP UPS\UPS1100. 3. Select the required battery module in the hardware catalog. In the "Information" area you can see information about the expansion module, and when necessary you can change the preselected (default) version. 4. Drag the battery module and drop it into the Device view. Alternatively, the battery module can be added by double-clicking on the entry in the hardware catalog. SITOP UPS1600 / UPS1100 56 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal 5. Drag the battery module and drop at the first free slot to the right next to the SITOP UPS1600. The battery module is inserted at the selected slot. 6. Save the hardware configuration. You have assigned a battery module to the basic device SITOP UPS1600. How you change the number and type of SITOP UPS1100 battery modules used is described under Parameterizing UPS1600 with STEP 7 in the TIA Portal (Page 58). SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 57 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal 3.3.7 Parameterizing the UPS1600 The adjustable parameters of the SITOP UPS1600 can be found in STEP 7 in the TIA Portal in the inspector window under Properties when the appropriate device was selected. For parameterization, in the area navigation, the settings under "Base Unit", "Energy storage" and "Webserver" are relevant. Navigation area Profinet security Description Profinet security DCP write protection activated Buffering All parameters, which involve the behavior of SITOP UPS1600 when buffering Navigation area Base Unit Description Signaling Setting of the alarm signaling and the wait time for stable input voltage. Energy storage - Parameters for the battery modules used Web server General information Define as to whether the SITOP UPS1600 may be accessed via web server (yes / no) Activate web server on this module Enable automatic logoff Access with HTTPS only. Automatic update Navigation area OPC UA server Description OPC UA server activated Here, activate the OPC UA server. Unencrypted access activated You have the option of activating unencrypted access to the OPC UA server. However, this option is not recommended. OPC UA server port Specify which port should be used. Navigation area NTP client Activate automatic update / Activation interval Description NTP client activated Here, activate the NTP client. NTP server address 1 ... 4 Enter up to 4 addresses for an NTP server. A detailed description of the individual parameters of the subgroups is contained in the associated section under Parameterizing the UPS in STEP 7 in the TIA Portal (Page 58). The procedure is the same for all parameters. This section describes the general procedure to reach the configuration dialog, using as example the parameters for buffering. The individual parameters and their possible values are described in the following subsections. Each parameter has a start value. A click on "Reset to initial values" resets all parameters of a subgroup to the associated start value. Preconditions The SITOP UPS1600 was integrated in the opened project. SITOP UPS1600 / UPS1100 58 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal Proceed as follows 1. Select the SITOP UPS1600 in the Device view. 2. In the inspector window select "Properties > General > Device configuration". Entries for parameterization are provided in the navigation area. "Buffering" parameters Parameter Value range Initial value Buffering allowed Yes / No Yes Connection threshold 21 - 25 V 22.5 V Buffer time 1 - 32767 s 600 s Maximum buffer time 1) Yes / No No 1 - 300 s 60 s 0 - 40 A 0A 18 - 23 V 18.5 V Additional buffer time after PC shutdown. Expected buffer current 3) 1) Stop buffering voltage Enable reset Yes / No No Reset time 1 - 120 s 5s Battery test interval 2) 1 - 65535 h 4h 1) Parameter only available from SW version V2.0 and higher 2) Parameter only available from SW version V2.1 and higher 3) valid from V2.0.4 or V2.1 Buffering permitted When the connection threshold is fallen below, selects whether the system is buffered or the output is shut down. Switch-in threshold Setting the switch-in threshold. Buffer time Length of time during which the system should be buffered by the SITOP UPS1600. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 59 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal Maximum buffer time The setting means that buffering is realized for as long as possible. The device only shuts down when the battery has discharged down to the defined stop buffering voltage. The value entered for the "Buffer time" parameter is not relevant in this case. Additional buffer time after PC shutdown Time during which the system should be buffered by the SITOP UPS1600 after the PC was shut down. Expected buffer current Load current, which is expected at the device output during buffer operation. Please adjust the correct application load current required. For current settings between 0 A and rated current, the display in the diagram "Remaining buffer time" is adapted. If a value of 0 A is entered, then for this parameter, the average value of the actual load current measured at the output over the last 10 min is assumed. The value of this parameter is used when calculating the remaining buffer time. The entered value may not exceed the rated device current. Note From the instant in time when the SITOP UPS1600 is switched over into the buffer mode, to determine the expected buffer time, instead of the expected buffer current, the actually measured buffer current is used. Stop buffering voltage The voltage at which battery discharge is terminated. The stop buffering voltage defined for this type is always used for a coded battery (UPS1100). Enable reset If the value is set to "Yes" then the output voltage is interrupted after the selected buffer time expires if, in the meantime, the input voltage returns. This option is useful, when, for example, computer networks are protected by the UPS that can be activated by a reset when the power supply is restored. For buffer time "MAX", the output voltage is not interrupted. Reset time Here, you define the interrupt duration. Battery test interval The time interval between battery tests can be set using the parameter. "Signaling" parameter Parameter Value range Default setting Downtime alarm 0 - 20,000 ms 100 ms Wait time for stable input voltage 0.2 - 65 s 1.0 s SITOP UPS1600 / UPS1100 60 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal Downtime alarm The time in which no alarm is issued to the system although it is buffered. Wait time for a stable input voltage Time where the input voltage must continually lie above the connection threshold so that buffering is exited and a transition is made into normal operation. "Energy storage" parameter The "energy storage" has two different areas that depend on the battery type being used. First select whether you are using a SITOP UPS1100 battery module or some other energy storage device. Possible parameters when using a SITOP UPS1100 battery module Parameter Value range Module Drop-down menu with the SITOP UPS1100 battery modules saved by the HSP Number of modules 0-6 Total capacity 0 - 72 Ah Module Type of SITOP UPS1100 battery module. Number of modules Number of installed modules. Total capacity Total capacity of the installed battery modules. Possible parameters for the deployment of a different battery module Parameter Value range Default setting Total capacity 0.1 - 3,200 Ah 10 Ah End-of-charge voltage 24 - 30 V 27.3 V Charge current 0.001 - 3 or 4 or 5 A 0.3 A Faulty battery voltage 1 - 18 V 6V SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 61 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal Total capacity Total capacity of the installed batteries. End of charge voltage Maximum voltage up to which the battery may be charged. Charge current The battery is not charged with more than the selected charge current. The manufacturer's details for the permitted battery charge current must be observed. Further, the following, device-dependent values apply: - SITOP UPS1600 10 A: Maximum permissible charge current 3,000 mA Derating for Tu > 40 C or Uin < 24 V: 2,000 mA - SITOP UPS1600 20 A: Maximum permissible charge current 4,000 mA Derating for Tu > 40 C or Uin < 24 V: 3,000 mA - SITOP UPS1600 40 A: Maximum permissible charge current 5,000 mA Derating for Tu > 40 C or Uin < 24 V: 3,000 mA Faulty battery voltage If the battery voltage undershoots this value, it is considered as being faulty by the SITOP UPS1600 and is not charged. "Web server" parameters Parameter Value range Default setting Activate web server on this module Yes / No Yes (up to V2.0) No (from V2.1) Permit access only with HTTPS Yes / No Yes Log off automatically after 15 minutes Yes / No No Update interval 0 / 5 s / 10 s / 20 s / 30 s / 60 s 30 s Enable automatic update Yes / No No Set here whether access to the UPS via web server is permitted. Activate web server on this module Define whether this device can be accessed via the web server. Permit access only with HTTPS Define whether access is only permissible via HTTPS. Log off automatically after 15 minutes You define whether a user should be automatically logged off after closing the web server. Update interval You define in which intervals the actual values are sent to the web server. Enable automatic update When you enable "Automatic update" then the actual values of the SITOP UPS1600 and connected supplementary modules are sent to the web server. SITOP UPS1600 / UPS1100 62 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal 3.3.8 Loading the configuration (commissioning) In the delivered state, the SITOP UPS1600 has not yet been assigned an IP address and the DHCP protocol is deactivated. When the SITOP UPS1600 is first connected with a controller (SIMATIC S7- control system), it must be assigned a device name and an IP address by the controller. A new configuration can be loaded to the device using STEP 7 in the TIA Portal . Identifying a SITOP UPS1600 in the network From the STEP 7 in the TIA Portal , you can get the LED "SF" at the SITOP UPS1600 to flash. This means that you can clearly identify a module in the network, e.g. if several SITOP UPS1600 are installed in the network. Preconditions The SITOP UPS1600 has been correctly connected and linked with the network. PG/PC with STEP 7 in the TIA Portal is connected with the network. Proceed as follows 1. Open the "Online > Accessible nodes" menu. 2. As type of PG/PC interface, select "PN/IE". 3. Select the PG/PC interface connected with the system. 4. Select the connection with the subnet, in which the SITOP UPS1600 is located. All of the available SITOP UPS1600 devices in the selected subnet are displayed. 5. Select the required SITOP UPS1600. 6. Activate the "Flash LED" checkbox. 7. Check at which SITOP UPS1600 in the network the "SF" LED flashes. By checking the flashing LEDs, you can uniquely identify all SITOP UPS1600 in a network. Note the device name and the IP address of the required SITOP UPS1600 in order to load a configuration. Changing the device name of the SITOP UPS1600 1. In STEP 7 , in the tabular area of the Network view, select the "Network overview" table. 2. Overwrite the name in the "Device" column in the row of the PROFINET device involved. You have changed the name of the SITOP UPS1600 device. The name is adapted in the graphical area of the network view. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 63 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal Changing the PROFINET device name of the SITOP UPS1600 via the properties of the PROFINET interface You can change the PROFINET device name using the properties of the PROFINET interface. 1. In the Network or Device view of the Hardware and Network editor of STEP 7, select the PROFINET interface of a PROFINET device. 2. In the Inspector window navigate to "Ethernet addresses" in the "PROFINET" area. 3. Deactivate the "Generate automatically the PROFINET device name" checkbox. 4. Enter the new PROFINET device name in the appropriate field. Changing the IP address of a SITOP UPS1600 1. In the Network or Device view of the hardware and network editor from STEP 7 in the TIA Portal , select the PROFINET interface of a PROFINET device. 2. In the Inspector window, navigate to "Ethernet addresses" in the "IP protocol" area. 3. Check whether the "Set IP address in the project" option is activated. 4. Enter the new IP address in the appropriate field. Loading the configuration to the SITOP UPS1600 To commission the UPS, you must load the project data that you created offline into the connected SITOP UPS1600. This project data results from the configuration of the hardware, networks and connections in STEP 7. Initially, the complete project data is loaded. Only the changes are loaded for subsequent load actions. Preconditions The project data is consistent. The device name must be identical offline and online. The SITOP UPS1600 is accessible online. The SITOP UPS1600 is located in the PROFINET IO system of an IO controller. The PG/PC is connected to the same network to which the SITOP UPS1600 and the controller are connected. The interface of the PG/PC must be set to TCP/IP. SITOP UPS1600 / UPS1100 64 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal Note Ensure that the article number of the SITOP UPS1600 configured offline matches the article number of the device connected online. The following response is obtained after loading the configuration into the device: Figure 3-1 Online / offline SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 65 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal Procedure 1. In the "Project tree", right-click on the SITOP UPS1600 controller. The shortcut menu opens. 2. In the shortcut menu, in submenu "Download to device", select option "Hardware configuration". The project data are compiled. The "Load" button is activated as soon as loading is possible. 3. Click on "Load". Data is loaded. The "Result of the load operation" dialog window is then opened. In this dialog, you can check whether the load task was successful and select any further actions. 4. Click on the "Finish" button. Result The set parameters have been loaded to the SITOP UPS1600 via the controller. SITOP UPS1600 / UPS1100 66 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal 3.3.9 Diagnostics The following data can be retrieved using the online and diagnostics function: Navigation area General Value Module Short designation Article number Hardware Firmware Module information Device name Module name Plant designation Location ID Manufacturer information Description of manufacturer Serial number Copyright entry Profile Profile details PROFINET interface Ethernet address / network connection MAC address Ethernet address / IP parameter IP address Subnet mask Default router IP settings IP setting time Functions Ports List of ports Assign an IP address MAC address IP address Subnet mask Router address Firmware update / UPS1600 Article number Firmware Name Rack Slot Firmware file Firmware version Suitable for modules with Status Activate firmware after update Assign name PROFINET device name Type Reset to factory settings MAC address IP address SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 67 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal Navigation area Value PROFINET device name Retrieve the online and diagnostics data of SITOP UPS1600 Proceed as follows to start the online and diagnostics view of the particular module: Project tree: 1. Open the device folder of the SITOP UPS1600 in the Project tree. This is located (after the assignment to the control system) in the folder of the control system under "Distributed I/O " > [name of the PROFINET connection]. 2. Double-click on "Online & diagnostics". Alternatively: 3. Select the device folder of the SITOP UPS1600 in the Project tree. 4. In the shortcut menu or in the "Online" main menu, select the "Online & diagnostics" . Device view: 1. Open the device view of the device configuration. 2. Select the SITOP UPS1600. 3. In the shortcut menu or in the "Online" main menu, select the "Online & diagnostics" . Network view: 1. Open the network view of the device configuration. 2. Select the SITOP UPS1600. 3. In the shortcut menu or in the "Online" main menu, select the "Online & diagnostics" . 4. Click on "Connect online". The information is displayed under "Diagnostics / General". SITOP UPS1600 / UPS1100 68 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal 3.3.10 Firmware update WARNING The SITOP UPS1600 is reset while updating the firmware. For safety reasons, the output is switched off. Ensure that no damage is caused to the plant or system. Ensure that the PG/PC and/or all switches, routers and gateways that are used have an independent power supply during the firmware update. WARNING Firmware update with UPS-Manager If for the firmware update, the UPS Manager is used, please note that for a firmware update from version V2.1 to V2.2 or higher, then a UPS Manager with version V4.72 or higher must be used. This also applies to firmware updates from V2.2.0 to higher versions. Note Install the current version of the SITOP UPS Managers, before you start the firmware update. It is possible that an older version (less than V4.5X) of the SITOP UPS Managers does not support this firmware update. The installation file for the SITOP UPS Manager is available at no charge on the SITOP home page (http://www.siemens.com/sitop) or directly (https://support.industry.siemens.com/cs/ww/en/view/75854607). Note Do not switch-off the devices during the firmware update. The files for updating the firmware (firmware updates) are available online under (http://support.automation.siemens.com/WW/view/en/79207181). Different firmware updates are offered depending on the amp rating of the SITOP UPS1600. Note Observe the compatibility of the firmware! Other firmware updates are not compatible. Determine the amp rating of your SITOP UPS1600 and download the appropriate firmware update. Note It is not possible to downgrade the device firmware to a release with a version number lower than the firmware installed in the device itself. Information on how to read out the firmware release from the device is provided in Section Diagnostics (Page 67). SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 69 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal Note "Reset to Factory" function: All configuration parameters are reset to the default setting; 0.0.0.0 is used for the IP address. A new IP address must then be assigned, as otherwise there is no connection to the UPS Manager or TIA Portal. Preconditions The SITOP UPS1600 has been correctly connected and linked with the system. PG/PC with STEP 7 in the TIA Portal is connected with the system. Online connection is established. Procedure The firmware update consists of several files, which are combined in a zip file. 1. Download the firmware update. 2. Unpack the ZIP file into a temporary directory. 3. In the network view, select the components whose firmware is to be updated. 4. Change to the device view. 5. Click on "Go online". 6. In the shortcut menu of the SITOP UPS1600, select "Online & Diagnostics". The "Online access" menu opens. 7. In the "Functions" folder, select the "Firmware update" group. 8. Click on the "Browse" button in the "Firmware loader" area to select the path to the directory with the unzipped files. 9. Select the appropriate file "*.upd". All SITOP UPS1600 are displayed in the table, for which an update is possible with the selected firmware file. 10.Click on the "Start update" button. If the selected file can be interpreted by the module, it will be loaded into the module. For version V2.1 - depending on the UPS1600 type - the firmware file is called "ups20a.upd", for example. If this requires changing the operating state of the CPU, you will be prompted to do this with dialogs. 11.Confirm the notes that are displayed. The firmware is sent from the controller to the component . While sending, LED 4 ("SF") and LED 6 ("RUN") flash at the SITOP UPS1600. SITOP UPS1600 / UPS1100 70 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal 12.Confirm the message from the TIA Portal that the data was successfully sent by pressing "OK". The firmware is saved in the internal component memory. The following LEDs flash while saving: - LED 1 ("OK/Bat") - LED 2 (">85%") Note It can take several minutes to save the firmware in the component. Do not switch-off the devices. 13.The device is automatically restarted after the LEDs no longer flash. Note During the firmware update, if the power supply of the SITOP UPS1600, or PG/PC or intermediate switches, routers or gateways is interrupted, then under certain circumstances, a fallback firmware is activated. If the SITOP UPS1600 can then no longer be accessed remotely, you must assign the a new IP address, or under the menu item "Assign name" you must enter a new name in the field "PROFINET device names" (see the manual for the particular unit). 14.The firmware has been updated. Only now is it permissible to switch off the SITOP UPS1600. Note After updating the firmware, in the hardware configuration of your project, you must replace the SITOP UPS1600 involved by SITOP UPS1600 with the current firmware version. The configured configuration then matches the actual configuration again. Note For GSD, the SITOP UPS1600 must be deleted, and newly integrated; this means that parameters, addresses and names must be newly set - and it is also possible that a new GSD file must first be installed. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 71 Engineering and remote access 3.3 SIMATIC STEP 7 in the TIA Portal 3.3.11 Restore factory settings A reset to the factory settings deletes all configurations of the PROFINET interface saved in the SITOP UPS1600 and restores the factory settings. This affects, for example: IP address Device name The parameter values for SITOP UPS1600 and the energy storage device are kept. Proceed as follows to reset the SITOP UPS1600 factory settings: 1. Select SITOP UPS1600 in the Network view and change to the Device view. 2. Click on "Go online". 3. In the SITOP UPS1600 shortcut menu, select "Online & diagnostics". 4. In the "Functions" folder, select the "Reset to factory settings" group. 5. Click on the "Reset" button. 6. Respond to the confirmation prompt with "OK". SITOP UPS1600 / UPS1100 72 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.4 SIMATIC STEP 7 3.4 SIMATIC STEP 7 3.4.1 Introduction The uninterruptible power supply SITOP UPS1600 can be used with SIMATIC STEP 7 from Version 5.4 and higher. In SIMATIC STEP 7 , the basic device SITOP UPS1600 and its SITOP UPS1100 battery modules can be integrated in the project, parameterized and diagnosed. Note SIMATIC STEP 7 and the SITOP UPS Manager cannot simultaneously access the SITOP UPS1600. It is not permissible that the SITOP UPS Manager service runs while the system is being accessed via SIMATIC STEP 7. 3.4.2 Installing the generic station description file (GSD) To use the SITOP UPS1600 and the SITOP UPS1100 battery modules in SIMATIC STEP 7, you must install the corresponding generic station description file (GSD). The GSD file is available at our SITOP-homepage (http://www.siemens.com/sitop-ups1600) or directly at (https://support.industry.siemens.com/cs/ww/en/view/75854605). Preconditions SIMATIC STEP 7 has been opened and a project has been created. At least one station has been added. You know where the GSD data have been saved. Procedure 1. Download the GSD file from the Internet. 2. Close all stations in HW Config. 3. Click on "Browse ...", and select the folder in which the GSD file is located. 4. Select the GSD file and click on "Install". Note If the file was not able to be installed, or if errors occurred during installation, then SIMATIC STEP 7 creates a report file. You can open this log file by clicking on the "Display log" button. 5. In the "Options" menu, click on "Update Catalog". The installed devices are imported into the module catalog and can then be integrated in the project. You can find SITOP UPS1600 in the hardware catalog under "PROFINET IO\I/O\UPS1600". SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 73 Engineering and remote access 3.4 SIMATIC STEP 7 3.4.3 Inserting SITOP UPS1600 into a project To be able to use the SITOP UPS1600 it must be assigned as IO device to an IO controller (SIMATIC S7 control) . Preconditions The GSD file of the SITOP UPS1600 has been correctly installed. SIMATIC STEP 7 has been opened, and a project with an IO controller (SIMATIC S7 control) has been created. Creating a subnet 1. Open the Hardware view "HW Config". 2. Call the shortcut menu of line "PN-IO" 3. Select "Insert PROFINET IO system". 4. In dialog field "Properties - Ethernet interface PN-IO", select the "Parameters" tab. 5. Set the IP address of the PROFINET interface. SITOP UPS1600 / UPS1100 74 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.4 SIMATIC STEP 7 6. Create a new subnet. 7. Confirm the properties of the new subnet. 8. Close the "Properties - Ethernet interface PN-IO" dialog box. The subnet is displayed as a horizontal line in the hardware view. Inserting SITOP UPS1600 from the hardware catalog 1. Select the subnet. 2. Open the "Catalog" window using the "View > Catalog" menu command. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 75 Engineering and remote access 3.4 SIMATIC STEP 7 3. In the hardware catalog, navigate to the SITOP UPS1600 under "PROFINET IO \ I/O \ UPS1600". 4. Click the desired SITOP UPS1600; keep the left mouse button pressed and drag the SITOP UPS1600 to the subnet. 5. Double-click on "SITOP UPS1600". 6. In the open dialog Device name, enter the device number and IP address in the Ethernet. 7. Save the hardware configuration. You have now inserted the SITOP UPS1600 into the project. The rectangle displayed in the editor symbolizes the SITOP UPS1600. SITOP UPS1600 / UPS1100 76 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.4 SIMATIC STEP 7 3.4.4 Parameter assignment 3.4.4.1 Parameters of the basic device and battery module The adjustable parameters of the basic device SITOP UPS1600 and the SITOP UPS1100 battery modules are structured according to subgroups in SIMATIC STEP 7. These subgroups are shown in the table below. Subgroup Description Buffer parameters All parameters, which involve the behavior of SITOP UPS1600 when buffering. Battery parameters Parameterizing the battery being used. Charging parameters Parameters for the charging behavior: * End-of-charge voltage * Charge current Reset parameters Activate interruption of the output voltage for supply system restoration. Buffering parameters Load current that is expected at the device output during buffer operation. Maintenance R test - the battery state is determined by subjecting it to a load. Identification Definition of the location and contact data to be able to identify the SITOP UPS1600. Web server Definition as to whether the SITOP UPS1600 may be accessed via web server (yes / no). A detailed description of the individual parameters of the subgroups is contained in the associated section under Parameterizing SITOP UPS1600 (Page 77). 3.4.4.2 Parameterizing SITOP UPS1600 The procedure is the same for all parameters. This section describes the general procedure to reach the configuration dialog. The individual parameters and their possible values are described in the following subsections. Each parameter has a start value. A click on "Reset to initial values" resets all parameters of a subgroup to the associated start value. Preconditions The SITOP UPS1600 has been integrated in the opened project and networked. Proceed as follows 1. Open Network view "NetPro" ("Tools > Configure network"). The controller and the networked SITOP UPS1600 are displayed. 2. In the Network view click on SITOP UPS1600. The hardware configuration opens. 3. Double click in the hardware configuration on the SITOP UPS1600 entry in the station window for slot 0.1. 4. In the configuration dialog click on the "Parameters" tab. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 77 Engineering and remote access 3.4 SIMATIC STEP 7 5. Click the desired subgroup. The subgroup opens. 6. Enter the values. 7. Confirm your entry by clicking on "OK". The parameters are stored in the project. Buffer parameters Parameter Buffer time Additional buffer time after the PC was powered Default setting 1 ... 32767 s 600 s 1 ... 300 s 60 s Connection threshold 21 ... 25 V 22.5 V Stop buffering voltage 18 ... 23 V 18.5 V Wait time for stable input voltage 200 ... 65,000 ms 1000 ms Downtime alarm 0 ... 20.000 ms 125 ms Buffering allowed Yes / No Yes Enable reset after buffering Yes / No No 1) down1) Value range valid from V2.0.4 or V2.1 SITOP UPS1600 / UPS1100 78 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.4 SIMATIC STEP 7 Buffer time Time where the system is to be buffered by SITOP UPS1600. The "Buffering allowed" parameter is used to specify whether buffering should be performed. If a value of 32767 is entered, then the SITOP UPS1600 interprets this as MAX, and only shuts down the buffering when the stop buffering voltage is reached. Additional backup time after the PC has been shutdown The time to be buffered by the SITOP UPS1600 once the PC has been shut down. Connection threshold If the connection threshold value is fallen below, the SITOP UPS1600 starts buffering. If the value of the connection threshold is subsequently exceeded again, then the SITOP UPS1600 stops buffering. Stop buffering voltage The voltage at which battery discharge is terminated. Wait time for a stable input voltage Time where the input voltage must continually lie above the connection threshold so that buffering is exited and a transition is made into normal operation. Downtime alarm The time in which no alarm is issued to the system although it is buffered. Buffering allowed Select between buffers with the specified values or passive measurement of the power supply by the SITOP UPS1600. Activate reset after buffering If the value is set to "yes", then, in the meantime, if the input voltage returns after the buffer time has expired, the SITOP UPS1600 shuts down the output for the selected interrupt time. Battery parameters Parameter Value range Default setting Faulty battery voltage 1 ... 18 V 6V Battery capacity 0.1 ... 3,200 Ah 10 Ah: Ignore data of coded battery Yes / No No Battery defective voltage If the battery voltage undershoots this value, it is considered as being defective by the SITOP UPS1600 and is not charged. Battery capacity If no UPS1100 battery modules are being used: Enter the total capacity of the installed batteries. Ignore data of coded battery Set the value to "Yes" if you define the parameters for the UPS1100 yourself. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 79 Engineering and remote access 3.4 SIMATIC STEP 7 Charging parameters Parameter Value range Default setting End-of-charge voltage 24 ... 30 V 26 V Charge current 1 ... 4,000 mA 800 mA End-of-charge voltage The end-of-charge voltage is the maximum voltage up to which the battery is charged. Charge current The battery is not charged with more than the selected charge current. The manufacturer's details for the permitted charge current of the battery must be observed. Note When UPS1100 battery modules are used, both parameters are automatically set, and do not have to be defined. The following, device-dependent maximum values apply: - SITOP UPS1600 10 A: Maximum permissible charge current 3,000 mA Derating for Tu > 40 C or Uin < 24 V: 2,000 mA - SITOP UPS1600 20 A: Maximum permissible charge current 4,000 mA Derating for Tu > 40 C or Uin < 24 V: 3,000 mA - SITOP UPS1600 40 A: Maximum permissible charge current 5,000 mA Derating for Tu > 40 C or Uin < 24 V: 3,000 mA Reset parameters Parameter Value range Default setting Reset time 1 ... 120 s 5s Here, you define the interrupt duration for the "Interrupt output voltage" function (reset after buffering) Buffering parameters (2) Parameter Value range Default setting Expected buffer current 0 ... 40 A 0A Load current, which is expected at the device output during buffer operation. Please adjust the correct application load current required. For current settings between 0 A and rated current, the display in the diagram "Remaining buffer time" is adapted. SITOP UPS1600 / UPS1100 80 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.4 SIMATIC STEP 7 If a value of 0 A is entered, then for this parameter, the average value of the actual load current measured at the output over the last 10 min is assumed. The value of this parameter is used when calculating the remaining buffer time. The entered value may not exceed the rated device current. Note From the instant in time when the SITOP UPS1600 is switched over into the buffer mode, to determine the expected buffer time, instead of the expected buffer current, the actually measured buffer current is used. Maintenance Parameter Value range Default setting R test interval 1 ... 65535 h 4h R test: The battery state is determined by subjecting it to a cyclic load. Identification Parameter Value range Contact Free text Location Free text Contact Enter, for example, a contact address or the name of a staff member. Location Enter a description of the location that can be used to locate the SITOP UPS1600. Web server Parameter Value range Default setting Activate web server on this module Yes / No No Permit access only with HTTPS Yes / No Yes Log off automatically after 15 minutes Yes / No No Enable automatic update Yes / No Yes Update interval 0 / 5 s / 10 s / 20 s / 30 s / 60 s 10 s Set here whether access to the SITOP UPS1600 via web server is permitted. Activate web server on this module Define whether this device can be accessed via the web server. Permit access only with HTTPS Define whether access is only permissible via HTTPS. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 81 Engineering and remote access 3.4 SIMATIC STEP 7 Log off automatically after 15 minutes You define whether a user should be automatically logged off after closing the web server. Update interval You define in which intervals the actual values are sent to the web server. 3.4.5 Loading the configuration to the SITOP UPS1600 (commissioning) In the delivered state, the SITOP UPS1600 has not yet been assigned any IP address and the DHCP protocol is deactivated. When the SITOP UPS1600 is first connected with an IO controller (SIMATIC S7 control system), it must be assigned a device name and an IP address by the IO controller. STEP 7 can be used to load a new configuration to the device. Preconditions The SITOP UPS1600 has been correctly connected and linked with the system. PG/PC with SIMATIC STEP 7 is connected with the network. Displaying accessible nodes Note If nodes can only be accessed via interposed switches or routers (with protocol conversion), they are not displayed in the list of the accessible nodes. 1. Click in menu "Target system" on "Display accessible nodes". The "Accessible nodes" window is opened with the following displays: - Station - SITOP UPS1600 The following table shows which information is displayed in the "Object name" column. Accessible nodes Object name Description S7-CPU, PC station Name of the station The "Details" view also shows the operating state, module type and, if available, information from the associated STEP 7 project (station name, CPU name, system identification). Loading the IO controller for the first time Once you have configured the SITOP UPS1600 and the station, you must load this configuration to the IO controller (SIMATIC S7 control system). This is the way that the IO controller is assigned its configured IP addresses. Before loading, carry out a consistency test to check the configuration for duplicate addresses, identical names, etc. SITOP UPS1600 / UPS1100 82 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.4 SIMATIC STEP 7 Inform yourself whether the IO controller to be loaded can also be initially loaded via the PROFINET interface. If not, you must first load the hardware configuration via the MPI interface . 1. Select in the "Target system > Load" menu. 2. Select the module to be loaded. 3. In the "Select node address" dialog, if necessary, click the "Display" button to display the actual accessible modules (these include the IO controller to be loaded with its current IP address or its MAC address, if no IP address is yet available). 4. Select the IO controller to be loaded from the accessible modules. This module is displayed in the "Enter connection to target station" dialog box. 5. Start loading by clicking on the "OK" button. The IO controller is assigned the configured IP address. Note Ensure that the article number of the SITOP UPS1600 configured offline matches the article number of the device connected online. The following response is obtained after loading the configuration into the device: SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 83 Engineering and remote access 3.4 SIMATIC STEP 7 Figure 3-2 Online / offline Allocating the SITOP UPS1600 a device name (online) In order that the configured IO controller can address the SITOP UPS1600, you must assign each individual IO device (including SITOP UPS1600) the configured device name. For the procedure described below, the SITOP UPS1600 and the station for the PG/PC must be accessible online on the Ethernet. 1. Open HW Config. 2. In the "Target system > Ethernet" menu, click on "Assign device name". 3. In the "Assign device name" dialog, in the "Device name" field, select SITOP UPS1600. 4. In the "Available devices" select the SITOP UPS1600. Using the "Flash" button, you can flash the LED on the SITOP UPS1600 so that the device can be uniquely identified. 5. Click on the "Assign name" button. After the name assignment, you can bring the IO controller into the RUN operating state. When powering up, the IO controller distributes the configuration information to the SITOP UPS1600 and then goes into cyclic operation. SITOP UPS1600 / UPS1100 84 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.4 SIMATIC STEP 7 3.4.6 Diagnostics The following data can be fetched using the Diagnostics function: Group Value SITOP UPS1600 general Article number Serial number Fetching diagnostics data You can use the "Station > Open online" menu command in "HW Config" to select the SITOP UPS1600 and view the diagnostics data. 3.4.7 Firmware update WARNING The SITOP UPS1600 is reset while updating the firmware. For safety reasons, the output is switched off. Ensure that no damage is caused to the plant or system. Ensure that the PG/PC and/or all switches, routers and gateways that are used have an independent power supply during the firmware update. WARNING Firmware update with UPS-Manager If for the firmware update, the UPS Manager is used, please note that for a firmware update from version V2.1 to V2.2 or higher, then a UPS Manager with version V4.72 or higher must be used. This also applies to firmware updates from V2.2.0 to higher versions. Note Install the current version of the SITOP UPS Managers, before you start the firmware update. It is possible that an older version (less than V4.5X) of the SITOP UPS Managers does not support this firmware update. The installation file for the SITOP UPS Manager is available at no charge on the SITOP home page (http://www.siemens.com/sitop) or directly (https://support.industry.siemens.com/cs/ww/en/view/75854607). Note Do not switch-off the devices during the firmware update. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 85 Engineering and remote access 3.4 SIMATIC STEP 7 The files for updating the firmware (firmware updates) are available online under (http://support.automation.siemens.com/WW/view/en/79207181). Different firmware updates are offered depending on the amp rating of the SITOP UPS1600. Note Observe the compatibility of the firmware! Other firmware updates are not compatible. Determine the amp rating of your SITOP UPS1600 and download the appropriate firmware update. Note It is not possible to downgrade the device firmware to a release with a version number lower than the firmware installed in the device itself. Information on how to read out the firmware release from the device is provided in Section Determining the firmware version (Page 132). Note "Reset to Factory" function: All configuration parameters are reset to the default setting; 0.0.0.0 is used for the IP address. A new IP address must then be assigned, as otherwise there is no connection to the UPS Manager or TIA Portal. See also Diagnostics (Page 85) Preconditions The SITOP UPS1600 has been correctly connected and linked with the PROFINET IO system. PG/PC with STEP 7 is connected with the network. Procedure The firmware update consists of several files, which are combined in a zip file. 1. Download the firmware update. 2. Unpack the ZIP file into a temporary directory. 3. Open the "Accessible nodes" window with the "Target system > Display accessible nodes" menu command. Note For an online connection via the "Accessible nodes" window, PG/PC and "Accessible nodes" must be connected to the same physical Ethernet subnet. 4. Select the "Target system > Update firmware" menu command. SITOP UPS1600 / UPS1100 86 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.4 SIMATIC STEP 7 5. Select the SITOP UPS1600 whose firmware is to be updated. 6. In the open "Update firmware" dialog, press the "Browse" button to select the path to the directory with the unzipped files. In this directory, select the corresponding "*.upd" file. 7. After you have selected a file, the information in the bottom fields of the "Update firmware" dialog box indicate the components for which the file is suitable and from which firmware version. 8. Click the "Run" button. 9. STEP 7 checks whether the selected file can be interpreted by the module; if the check is positive, then the file is loaded to the module. 10.If this requires changing the operating state of the IO controller, then you will be prompted to do this in the relevant dialog boxes. 11.The module then automatically updates the firmware. Note A separate connection is established to the CPU for the firmware update, if available. In this case, the task can be interrupted. If no resources are available for another connection, an existing connection will be used automatically. In this case, the task cannot be interrupted; the "Cancel" button in the transfer dialog is grayed-out and cannot be operated. 12.Confirm the notes that are displayed. The firmware is sent from the IO controller to the component, and saved in the internal component memory. The following LEDs flash while saving: - LED 1 ("OK/Bat") - LED 2 (">85%") Note It can take several minutes to save the firmware in the component. Do not switch-off the devices. Note During the firmware update, if the power supply of the SITOP UPS1600, or PG/PC or intermediate switches, routers or gateways is interrupted, then under certain circumstances, a fallback firmware is activated. If the SITOP UPS1600 can then no longer be accessed remotely, you must assign the SITOP UPS1600 a new IP address, or under the menu item "Assign name" you must enter a new name in the field "PROFINET device names" (see the manual for the particular device). 13.The SITOP UPS1600 automatically updates the firmware. 14.The firmware has been updated. Only now is it permissible to switch off the SITOP UPS1600. 15.Using STEP 7 (read out the diagnostics buffer of the IO controller), check whether SITOP UPS1600 successfully starts with the new firmware. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 87 Engineering and remote access 3.4 SIMATIC STEP 7 Note After updating the firmware, in the hardware configuration of your project, you must replace the SITOP UPS1600 involved by the SITOP UPS1600 with the current firmware version. The configured configuration then matches the actual configuration again. SITOP UPS1600 / UPS1100 88 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.4 SIMATIC STEP 7 3.4.8 Restore factory settings With STEP 7 Version 5.5, it is possible to restore the factory setting of modules using the "Target system -> Edit Ethernet node". 1. To select the MAC address of the SITOP UPS1600, which should be reset to the factory setting, click in dialog "Edit Ethernet node" on "Browse". 2. Click on the "Reset" button. This deletes the IP address and the device name from the module. The parameter values for SITOP UPS1600 and the energy storage device are kept. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 89 Engineering and remote access 3.5 Cyclic and acyclic data 3.5 Cyclic and acyclic data The data communicated between SITOP UPS1600 and the PROFINET IO-Controller can be viewed in SIMATIC STEP 7 or SIMATIC STEP 7 in the TIA Portal. Here, a distinction is made between cyclic data (input/output data) and acyclic data (reading/writing data sets). Input/output data SITOP UPS1600 sends, in cyclic intervals (1 ms - 512 ms for IRT or 1 ms - 2048 ms for RT), data about the actual operating states to the PROFINET IO-Controller. You will find more information on this at Input and output data (Page 90). Reading and writing data sets Reading and writing data sets are sent acyclically from the SITOP UPS1600 to the PROFINET IO-Controller or from the PROFINET IO-Controller to the SITOP UPS1600. Additional information can be found at Reading and writing data sets (Page 91). 3.5.1 Input and output data An overview of the input and output data, which is cyclically sent from the SITOP UPS1600 to the PROFINET IO controller is provided in the following tables. Slot Subslot Data Description Data size 0 2 Input voltage Input voltage is present: Unsigned8 Buffer mode Ready for buffering Charge sufficient * 0: NOT OK * 255: OK Buffer mode: The load connected to the SITOP UPS1600 is supplied via the energy storage device connected to the SITOP UPS1600: * 0: inactive * 255: active Ready for buffer operation as the energy storage device of the buffer component has been sufficiently charged. * 0: NOT OK * 255: OK Charge level sufficient: When this flag is set, the required charge level has been achieved: * 0: NOT OK * 255: OK Unsigned8 Unsigned8 Unsigned8 SITOP UPS1600 / UPS1100 90 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.5 Cyclic and acyclic data Slot Subslot Data Description Data size Battery change recommended Battery replacement recommended: Battery capacity is insufficient to achieve the specified buffer time: Unsigned8 0: no * 255: yes Not used - Unsigned8 Battery charge level Battery charge level in %: Unsigned8 Battery connection maintenance from V2.1 3.5.2 * * 0-100: 0-100% * 255: unknown battery Connection to the battery interrupted: Check the connection and fuse: * 0: no maintenance required * 255: maintenance required Unsigned8 Reading and writing data sets An overview of all data sets, which are communicated between the SITOP UPS1600 and the PROFINET IO-Controller is provided in the following table. Here, a distinction is made between the following data sets: Reading data sets: Data which is sent from the SITOP UPS1600 to the PROFINET IO-Controller . Writing data sets: Data which is sent from the PROFINET IO-Controller to the SITOP UPS1600. Index Slot Subslot Data set Type Description Data size 0x0001 0 1 Buffering parameters Reading / writing Buffer parameters. 14 bytes 0x0002 0 1 Battery parameters Reading / writing Parameters of the connected battery modules 5 bytes 0x0003 0 1 Charging parameters Reading / writing Charge parameters of the connected battery modules 4 bytes 0x0004 0 1 Reset parameters Reading / writing Reset parameters. 1 byte 0x0005 0 1 Battery information parameters Reading Information about the connected battery 1024 bytes modules SITOP UPS1100. This information is available via the link "Energy Storage". 0x0006 0 1 Device information Parameters Reading Information about the SITOP UPS1600. 148 bytes 0x0007 0 1 Hardware settings parameters Reading Hardware settings of the SITOP UPS1600 (settings that were made at the front of the device). 8 bytes SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 91 Engineering and remote access 3.5 Cyclic and acyclic data Index Subslot Data set Type Description Data size 0x0008 0 Slot 1 Buffering parameters from V2.0 Reading / writing Buffer parameters of the SITOP UPS1600 2 bytes 0x0009 0 1 Maintenance parameters from V2.1 Reading / writing Maintenance parameters of the SITOP UPS1600 2 bytes 0x0010 0 1 DC-UPS command Writing Sends special commands to the SITOP UPS1600 4 bytes 0x0010 0 1 Result of DC-UPS command Reading Response to the previously sent 4 bytes 0x0011 0 1 Battery 1 information parameters Reading Information regarding the connected battery module 1 SITOP UPS1100. This information is available via the link "Energy Storage". 68bytes (from V2.2) 0x0012 0 1 Battery 2 information parameters Reading Information regarding the connected battery module 2 SITOP UPS1100. This information is available via the link "Energy Storage". 68bytes (from V2.2) 0x0013 0 1 Battery 3 information parameters Reading Information regarding the connected battery module 3 SITOP UPS1100. This information is available via the link "Energy Storage". 68bytes (from V2.2) 0x0014 0 1 Battery 4 information parameters Reading Information regarding the connected battery module 4 SITOP UPS1100. This information is available via the link "Energy Storage". 68bytes (from V2.2) 0x0015 0 1 Battery 5 information parameters Reading Information regarding the connected battery module 5 SITOP UPS1100. This information is available via the link "Energy Storage". 68bytes (from V2.2) 0x0016 0 1 Battery 6 information parameters Reading Information regarding the connected battery module 6 SITOP UPS1100. This information is available via the link "Energy Storage". 68bytes (from V2.2) 0x0020 0 1 State information Reading Status information about SITOP UPS1600 and the connected battery modules SITOP UPS1100. Information about the SITOP UPS1100 battery modules is available via the link "Energy Storage". 64 bytes 70 bytes (from V2.1) 0x0040 0 1 Identification value parameters Reading / writing Device identification parameters. 80 bytes 108 bytes (from V2.1) 0x0041 0 1 Web server parameters Reading / writing Web server settings of the SITOP UPS1600. 1 byte 6 bytes (from V2.1) 0x0042 0 1 OPC UA server Reading/ writing OPC UA settings of the SITOP UPS1600. 4 bytes (from V2.2) 0x0043 0 1 NTP client parameters Reading/ writing Setting for connection to NTP servers 66 bytes (from V2.2) "DC-UPS command" SITOP UPS1600 / UPS1100 92 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.5 Cyclic and acyclic data Index Subslot Data set Type Description Data size 0x0044 0 Slot 1 NTP client status parameters Reading Status NTP client 40 bytes (from V2.2) 0x0045 0 1 PROFINETSecurity Reading/ writing Setting for DCP write protection 2 bytes (from V2.2) You can find detailed information about the individual data sets in Section Data sets (Page 93) 3.5.2.1 Data sets In this section you can find detailed information about the individual data sets that are sent from the PROFINET IO-Controller to the SITOP UPS1600 - and which can be read from the SITOP UPS1600. 0x0001: Buffering parameters (reading/writing) Data Description Data type Buffer time [1 s] Buffer time: After the selected buffer time has expired, the SITOP UPS1600 switches off the load output. The actual buffer time that can be achieved depends on the connected loads and energy storage devices. Unsigned16 Buffer time 2 [1 s] Additional buffer time after the PC was shut down. (only valid in conjunction with PC software SITOP UPS Manager) Unsigned16 Buffer threshold [0.01 V] Connection threshold: Switching voltage for buffering. Buffering is active below this value. Unsigned16 Stop buffering voltage [0.01 V] Buffer operation is exited if the battery voltage is below this value. Unsigned16 Input voltage OK time [1 ms] Wait time for stable input voltage: Minimum time during which the input voltage during buffer operation must be available at the SITOP UPS1600 to exit buffer operation of the SITOP UPS1600 and to again supply the connected loads via the input voltage (normal operation). Unsigned16 Downtime alarm [1 ms] Downtime alarm: Alarm filter: An alarm is only sent if it is active for longer than the set time. Unsigned16 Buffering allowed Activate or deactivate buffer operation. The setting is only accepted in operating mode Remote Enable (REN) of the SITOP UPS1600. Unsigned8 Enable reset after buffering Enable reset after buffering: If, during buffer operation, the input voltage becomes available again, then the output is switched off for a selectable time in order to reset the connected devices. Unsigned8 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 93 Engineering and remote access 3.5 Cyclic and acyclic data 0x0002: Battery parameters (reading/writing) Data Description Data type Battery defect voltage [0.01 V] Battery defect voltage: If the battery voltage falls below the set value, then the battery is identified to be defective. Unsigned16 Battery capacity [0.1 Ah] Battery capacity: Total battery capacity of all energy storage devices connected to the SITOP UPS1600. Unsigned16 Ignore battery coding Ignore data of the coded battery: When this parameter is set to "1", then data of the coded battery is ignored. Instead, data is taken from the parameterization ("Battery Parameters", "Charging Parameters"). Unsigned8 0x0003: Charging parameters (reading/writing) Data Description Data type End of charge voltage [0.01 V] End of charge voltage: Battery voltage when charging changes to trickle charging. The connected energy storage device is then charged up to 100 %. Unsigned16 Charge current [1 mA] Charge current: Current magnitude used to charge the connected battery modules during the constant charging process. Unsigned16 0x0004: Reset parameters (reading/writing) Data Description Data type Reset time [1 s] Reset time: Time during which the SITOP UPS1600 output is shutdown if the connected devices are reset. Unsigned8 0x0005: Battery information parameters (reading) Data Description Data type Number of batteries Number of connected battery modules. Here, only the SITOP UPS1100 battery modules (coded batteries) are counted. Unsigned8 Fill byte(s) - 3 x Unsigned8 Batt 1: Standby time [1 s] Standby time Unsigned32 Batt 1: Buffer time [1 s] Required buffer time, after which the SITOP UPS1600 shuts down in the buffer mode. Unsigned32 Batt 1: Total charging current [1 mAh] Total charge level (battery-specific data): Total charge within the service lifetime of the SITOP UPS1600. Unsigned32 Batt 1: Total culled current [1 mAh] Total charge level used (battery-specific data): Total discharge over the lifetime of the SITOP UPS1600. Unsigned32 Batt 1: EOCV [0.01 V] "End-of-charge voltage": Battery voltage when charging changes to trickle charging. The energy storage device is then charged up to 100 %. Unsigned16 Batt 1: Charge current [1 mA] Charge current: Current magnitude used to charge the connected battery modules during the constant charging process. Unsigned16 SITOP UPS1600 / UPS1100 94 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.5 Cyclic and acyclic data Data Description Data type Batt 1: Battery capacity [0.1 Ah] Battery capacity: Total battery capacity of all energy storage devices connected to the SITOP UPS1600. Unsigned16 Batt 1: Stop buffering voltage [0.01 V] Stop buffering voltage: Buffer operation is exited if the battery voltage is below this value. Unsigned16 Batt 1: Battery type Battery type Unsigned8 Batt 1: Minimal temperature [1 C] Lowest specified operating temperature of the battery module being used SITOP UPS1100. Signed8 Batt 1: Maximal temperature [1 C] Highest specified operating temperature of the battery module being used SITOP UPS1100. Signed8 Fill byte(s) - 3 x Unsigned8 Batt 1: Order number Order number (Article number). VisibleString(30) Batt 1: Serial number Serial number VisibleString(30) Batt 1: Manufacturing date Manufacturing date VisibleString(30) Batt 1: Version number Version number VisibleString(50) Batt 2: Standby time [1 s] Standby time Unsigned32 Batt 2 Buffer time [1 s] Required buffer time, after which the SITOP UPS1600 shuts down in the buffer mode. Unsigned32 Batt 2: Total charging current [1 mAh] Total charge level (battery-specific data): Total charge within the service lifetime of the SITOP UPS1600. Unsigned32 Batt 2: Total culled current [1 mAh] Total charge level used (battery-specific data): Total discharge over the lifetime of the SITOP UPS1600. Unsigned32 Batt 2: EOCV [0.01 V] "End-of-charge voltage": Battery voltage when charging changes to trickle charging. The energy storage device is then charged up to 100 %. Unsigned16 Batt 2: Charge current [1 mA] Charge current: Current magnitude used to charge the connected battery modules during the constant charging process. Unsigned16 Batt 2: Battery capacity [0.1 Ah] Battery capacity: Total battery capacity of all energy storage devices connected to the SITOP UPS1600. Unsigned16 Batt 2 Stop buffering voltage [0.01 V] Stop buffering voltage: Buffer operation is exited if the battery voltage is below this value. Unsigned16 Batt 2: Battery type Battery type Unsigned8 Batt 2: Minimal temperature [1 C] Lowest specified operating temperature of the battery module being used SITOP UPS1100. Signed8 Batt 12 Maximal temperature [1 C] Highest specified operating temperature of the battery module being used SITOP UPS1100. Signed8 Fill byte(s) - 3 x Unsigned8 Batt 2: Order number Order number (Article number). VisibleString(30) Batt 2: Serial number Serial number VisibleString(30) Batt 2: Manufacturing date Manufacturing date VisibleString(30) Batt 2: Version number Version number VisibleString(50) Batt 3: Standby time [1 s] Standby time Unsigned32 Batt 3: Buffer time [1 s] Required buffer time, after which the SITOP UPS1600 shuts down in the buffer mode. Unsigned32 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 95 Engineering and remote access 3.5 Cyclic and acyclic data Data Description Data type Batt 3: Total charging current [1 mAh] Total charge level (battery-specific data): Total charge within the service lifetime of the SITOP UPS1600. Unsigned32 Batt 3: Total culled current [1 mAh] Total charge level used (battery-specific data): Total discharge within the service life of the SITOP UPS1600. Unsigned32 Batt 3: EOCV [0.01 V] "End-of-charge voltage": Battery voltage when charging changes to trickle charging. The energy storage device is then charged up to 100 %. Unsigned16 Batt 3: Charge current [1 mA] Charge current: Current magnitude used to charge the connected battery modules during the constant charging process. Unsigned16 Batt 3: Battery capacity [0.1 Ah] Battery capacity: Total battery capacity of all energy storage devices connected to the SITOP UPS1600. Unsigned16 Batt 3: Stop buffering voltage [0.01 V] Stop buffering voltage: Buffer operation is exited if the battery voltage is below this value. Unsigned16 Batt 3: Battery type Battery type Unsigned8 Batt 3: Minimal temperature [1 C] Lowest specified operating temperature of the battery module being used SITOP UPS1100. Signed8 Batt 3: Maximal temperature [1 C] Highest specified operating temperature of the battery module being used SITOP UPS1100. Signed8 Fill byte(s) - 3 x Unsigned8 Batt 3: Order number Order number (Article number). VisibleString(30) Batt 3 Serial number Serial number VisibleString(30) Batt 3: Manufacturing date Manufacturing date VisibleString(30) Batt 3: Version number Version number VisibleString(50) Batt 4: Standby time [1 s] Standby time Unsigned32 Batt 4: Buffer time [1 s] Required buffer time, after which the SITOP UPS1600 shuts down in the buffer mode. Unsigned32 Batt 4: Total charging current [1 mAh] Total charge level (battery-specific data): Total charge within the service lifetime of the SITOP UPS1600. Unsigned32 Batt 4: Total culled current [1 mAh] Total charge level used (battery-specific data): Total discharge over the lifetime of the SITOP UPS1600. Unsigned32 Batt 4: EOCV [0.01 V] "End-of-charge voltage": Battery voltage when charging changes to trickle charging. The energy storage device is then charged up to 100 %. Unsigned16 Batt 4: Charge current [1 mA] Charge current: Current magnitude used to charge the connected battery modules during the constant charging process. Unsigned16 Batt 4: Battery capacity [0.1 Ah] Battery capacity: Total battery capacity of all energy storage devices connected to the SITOP UPS1600. Unsigned16 Batt 4: Stop buffering voltage [0.01 V] Stop buffering voltage: Buffer operation is exited if the battery voltage is below this value. Unsigned16 Batt 4: Battery type Battery type Unsigned8 Batt 4: Minimal temperature [1 C] Lowest specified operating temperature of the battery module being used SITOP UPS1100. Signed8 Batt 4: Maximal temperature [1 C] Highest specified operating temperature of the battery module being used SITOP UPS1100. Signed8 Fill byte(s) - 3 x Unsigned8 SITOP UPS1600 / UPS1100 96 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.5 Cyclic and acyclic data Data Description Data type Batt 4: Order number Order number (Article number). VisibleString(30) Batt 4: Serial number Serial number VisibleString(30) Batt 4: Manufacturing date Manufacturing date VisibleString(30) Batt 4: Version number Version number VisibleString(50) Batt 5: Standby time [1 s] Standby time Unsigned32 Batt 5: Buffer time [1 s] Required buffer time, after which the SITOP UPS1600 shuts down in the buffer mode. Unsigned32 Batt 5: Total charging current [1 mAh] Total charge level (battery-specific data): Total charge within the service lifetime of the SITOP UPS1600. Unsigned32 Batt 5: Total culled current [1 mAh] Total charge level used (battery-specific data): Total discharge within the service life of the SITOP UPS1600. Unsigned32 Batt 5: EOCV [0.01 V] "End-of-charge voltage": Battery voltage when charging changes to trickle charging. The energy storage device is then charged up to 100 %. Unsigned16 Batt 5: Charge current [1 mA] Charge current: Current magnitude used to charge the connected battery modules during the constant charging process. Unsigned16 Batt 5: Battery capacity [0.1 Ah] Battery capacity: Total battery capacity of all energy storage devices connected to the SITOP UPS1600. Unsigned16 Batt 5: Stop buffering voltage [0.01 V] Stop buffering voltage: Buffer operation is exited if the battery voltage is below this value. Unsigned16 Batt 5: Battery type Battery type Unsigned8 Batt 5: Minimal temperature [1 C] Lowest specified operating temperature of the battery module being used SITOP UPS1100. Signed8 Batt 5: Maximal temperature [1 C] Highest specified operating temperature of the battery module being used SITOP UPS1100. Signed8 Fill byte(s) - 3 x Unsigned8 Batt 5: Order number Order number (Article number). VisibleString(30) Batt 5: Serial number Serial number VisibleString(30) Batt 5: Manufacturing date Manufacturing date VisibleString(30) Batt 5: Version number Version number VisibleString(50) Batt 6: Standby time [1 s] Standby time Unsigned32 Batt 6 Buffer time [1 s] Required buffer time, after which the SITOP UPS1600 shuts down in the buffer mode. Unsigned32 Batt 6: Total charging current [1 mAh] Total charge level (battery-specific data): Total charge within the service lifetime of the SITOP UPS1600. Unsigned32 Batt 6: Total culled current [1 mAh] Total charge level used (battery-specific data): Total discharge within the service life of the SITOP UPS1600. Unsigned32 Batt 6: EOCV [0.01 V] "End-of-charge voltage": Battery voltage when charging changes to trickle charging. The energy storage device is then charged up to 100 %. Unsigned16 Batt 6: Charge current [1 mA] Charge current: Current magnitude used to charge the connected battery modules during the constant charging process. Unsigned16 Batt 6: Battery capacity [0.1 Ah] Battery capacity: Total battery capacity of all energy storage devices connected to the 'SITOP UPS1600. Unsigned16 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 97 Engineering and remote access 3.5 Cyclic and acyclic data Data Description Data type Batt 6: Stop buffering voltage [0.01 V] Stop buffering voltage: Buffer operation is exited if the battery voltage is below this value. Unsigned16 Batt 6: Battery type Battery type Unsigned8 Batt 6: Minimal temperature [1 C] Lowest specified operating temperature of the battery module being used SITOP UPS1100. Signed8 Batt 6: Maximal temperature [1 C] Highest specified operating temperature of the battery module being used SITOP UPS1100. Signed8 Fill byte(s) - 3 x Unsigned8 Batt 6: Order number Order number (Article number). VisibleString(30) Batt 6: Serial number Serial number VisibleString(30) Batt 6: Manufacturing date Manufacturing date VisibleString(30) Batt 6: Version number Version number VisibleString(50) 0x0006: Device information parameters (reading) Data Description Data type HW revision Hardware version Unsigned16 SW revision Software release Unsigned16 Boot loader version Boot loader version Unsigned16 Max output current [1 A] Maximum output current Unsigned8 Fill byte(s) - Unsigned8 MLFB/Order number MLFB/order number (Article number) VisibleString(30) Serial number Serial number VisibleString(30) Device name Device name VisibleString(30) Version number Version number VisibleString(50) 0x0007: Hardware setting parameters (reading) Data Description Data type Buffer time [1 s] Buffer time: After the selected buffer time has expired, the SITOP UPS1600 switches off the load output. The actual buffer time that can be achieved depends on the connected loads and energy storage devices. Unsigned16 Buffer threshold [0.01 V] Connection threshold: Switching voltage for buffering. Buffering is active below this value. Unsigned16 Buffering allowed Activate or deactivate buffer operation. The setting is only accepted in operating mode Remote Enable (REN) of the SITOP UPS1600. Unsigned8 Enable reset Enable reset: If, during buffer operation, the input voltage becomes available again, then the output of the SITOP UPS1600 is switched off for a selectable time in order to reset connected loads. Unsigned8 SITOP UPS1600 / UPS1100 98 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.5 Cyclic and acyclic data Data Description Data type Start from battery Start from battery: Setting at the signal terminal for function "Start from battery". Unsigned8 Selected battery profile Profile of the selected battery: The battery charging behavior is set Unsigned8 at the signal terminals. The setting is only used, if the SITOP UPS1600 is not in the "Remote Enable" (REN) mode 0x0008: Buffering parameters (reading/writing) Data Description Data type Expected buffer current [0.1 Ah] from V2.0 and higher Expected buffer current: Estimated average load current during buffer operation. Unsigned16 0x0009: Maintenance parameters (reading/writing) Data Description Data type Resistor test interval [1 h] from V2.1 R test interval Unsigned16 0x0010: DC-UPS command (writing) Data Description Data type CommandID Remote reset: 8195 Unsigned16 Parameter 1 Not used Unsigned8 Parameter 2 Toff : output voltage down time [s] Unsigned8 >= V1.0 Data Description Data type CommandID Remote reset 2: 8207 Unsigned16 Parameter 1 Td: Waiting time after end of communication [s] Unsigned8 Toff : output voltage down time [s] Unsigned8 Parameter 2 >= V2.0.0 Data Description Data type CommandID Output ON/OFF: 8200 Unsigned16 Parameter 1 0 Unsigned8 Parameter 2 0: output OFF Unsigned8 1: output ON SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 99 Engineering and remote access 3.5 Cyclic and acyclic data Data Description Data type CommandID Reset to Factors-Values: 8209 Unsigned16 Parameter 1 Not used Unsigned8 Parameter 2 Not used Unsigned8 >= V2.1.0 0x0010: Result of DC-UPS command (reading) Data Description Data type CommandID CommandID (of the previously sent command) Unsigned16 Parameter 1 0: OK Unsigned16 > 0: Error 0x0011: Battery 1 information parameters (reading) Data Description Data type Number of batteries Number of batteries Unsigned8 from V2.2 Battery 1 available 0 ... not available 1 ... available Unsigned8 from V2.2 Minimal temperature Minimal temperature Signed8 from V2.2 Maximal temperature Maximal temperature Signed8 from V2.2 Standby time Standby time Unsigned32 from V2.2 Buffer time Buffer time Unsigned32 from V2.2 Total charging current Total charging current Unsigned32 from V2.2 Total culled current Total culled current Unsigned32 from V2.2 EOCV End-of-charge voltage Unsigned16 from V2.2 Charge current Charge current Unsigned16 from V2.2 Battery capacity Battery capacity Unsigned16 from V2.2 Stop buffering voltage Stop buffering voltage Unsigned16 from V2.2 Battery type Battery type Unsigned8 from V2.2 Order number Order number VisibleString(19) from V2.2 SITOP UPS1600 / UPS1100 100 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.5 Cyclic and acyclic data Data Description Data type Serial number Serial number VisibleString(15) from V2.2 Manufacturing date Manufacturing date 3 x Unsigned8 from V2.2 Version number Version number 2 x Unsigned8 from V2.2 0x0012: Battery 2 information parameters (reading) Data Description Data type Number of batteries Number of batteries Unsigned8 from V2.2 Battery 2 available 0 ... not available 2 ... available Unsigned8 from V2.2 Minimal temperature Minimal temperature Signed8 from V2.2 Maximal temperature Maximal temperature Signed8 from V2.2 Standby time Standby time Unsigned32 from V2.2 Buffer time Buffer time Unsigned32 from V2.2 Total charging current Total charging current Unsigned32 from V2.2 Total culled current Total culled current Unsigned32 from V2.2 EOCV End-of-charge voltage Unsigned16 from V2.2 Charge current Charge current Unsigned16 from V2.2 Battery capacity Battery capacity Unsigned16 from V2.2 Stop buffering voltage Stop buffering voltage Unsigned16 from V2.2 Battery type Battery type Unsigned8 from V2.2 Order number Order number VisibleString(19) from V2.2 Serial number Serial number VisibleString(15) from V2.2 Manufacturing date Manufacturing date 3 x Unsigned8 from V2.2 Version number Version number 2 x Unsigned8 from V2.2 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 101 Engineering and remote access 3.5 Cyclic and acyclic data 0x0013: Battery 3 information parameters (reading) Data Description Data type Number of batteries Number of batteries Unsigned8 from V2.2 Battery 3 available 0 ... not available 3 ... available Unsigned8 from V2.2 Minimal temperature Minimal temperature Signed8 from V2.2 Maximal temperature Maximal temperature Signed8 from V2.2 Standby time Standby time Unsigned32 from V2.2 Buffer time Buffer time Unsigned32 from V2.2 Total charging current Total charging current Unsigned32 from V2.2 Total culled current Total culled current Unsigned32 from V2.2 EOCV End-of-charge voltage Unsigned16 from V2.2 Charge current Charge current Unsigned16 from V2.2 Battery capacity Battery capacity Unsigned16 from V2.2 Stop buffering voltage Stop buffering voltage Unsigned16 from V2.2 Battery type Battery type Unsigned8 from V2.2 Order number Order number VisibleString(19) from V2.2 Serial number Serial number VisibleString(15) from V2.2 Manufacturing date Manufacturing date 3 x Unsigned8 from V2.2 Version number Version number 2 x Unsigned8 from V2.2 0x0014 Battery 4 information parameters (reading) Data Description Data type Number of batteries Number of batteries Unsigned8 from V2.2 Battery 4 available 0 ... not available 4 ... available Unsigned8 from V2.2 Minimal temperature Minimal temperature Signed8 from V2.2 SITOP UPS1600 / UPS1100 102 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.5 Cyclic and acyclic data Data Description Data type Maximal temperature Maximal temperature Signed8 from V2.2 Standby time Standby time Unsigned32 from V2.2 Buffer time Buffer time Unsigned32 from V2.2 Total charging current Total charging current Unsigned32 from V2.2 Total culled current Total culled current Unsigned32 from V2.2 EOCV End-of-charge voltage Unsigned16 from V2.2 Charge current Charge current Unsigned16 from V2.2 Battery capacity Battery capacity Unsigned16 from V2.2 Stop buffering voltage Stop buffering voltage Unsigned16 from V2.2 Battery type Battery type Unsigned8 from V2.2 Order number Order number VisibleString(19) from V2.2 Serial number Serial number VisibleString(15) from V2.2 Manufacturing date Manufacturing date 3 x Unsigned8 from V2.2 Version number Version number 2 x Unsigned8 from V2.2 0x0015: Battery 5 information parameters (reading) Data Description Data type Number of batteries Number of batteries Unsigned8 from V2.2 Battery 5 available 0 ... not available 5 ... available Unsigned8 from V2.2 Minimal temperature Minimal temperature Signed8 from V2.2 Maximal temperature Maximal temperature Signed8 from V2.2 Standby time Standby time Unsigned32 from V2.2 Buffer time Buffer time Unsigned32 from V2.2 Total charging current Total charging current Unsigned32 from V2.2 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 103 Engineering and remote access 3.5 Cyclic and acyclic data Data Description Data type Total culled current Total culled current Unsigned32 from V2.2 EOCV End-of-charge voltage Unsigned16 from V2.2 Charge current Charge current Unsigned16 from V2.2 Battery capacity Battery capacity Unsigned16 from V2.2 Stop buffering voltage Stop buffering voltage Unsigned16 from V2.2 Battery type Battery type Unsigned8 from V2.2 Order number Order number VisibleString(19) from V2.2 Serial number Serial number VisibleString(15) from V2.2 Manufacturing date Manufacturing date 3 x Unsigned8 from V2.2 Version number Version number 2 x Unsigned8 from V2.2 0x0016: Battery 6 information parameters (reading) Data Description Data type Number of batteries Number of batteries Unsigned8 from V2.2 Battery 6 available 0 ... not available 6 ... available Unsigned8 from V2.2 Minimal temperature Minimal temperature Signed8 from V2.2 Maximal temperature Maximal temperature Signed8 from V2.2 Standby time Standby time Unsigned32 from V2.2 Buffer time Buffer time Unsigned32 from V2.2 Total charging current Total charging current Unsigned32 from V2.2 Total culled current Total culled current Unsigned32 from V2.2 EOCV End-of-charge voltage Unsigned16 from V2.2 Charge current Charge current Unsigned16 from V2.2 Battery capacity Battery capacity Unsigned16 from V2.2 SITOP UPS1600 / UPS1100 104 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.5 Cyclic and acyclic data Data Description Data type Stop buffering voltage Stop buffering voltage Unsigned16 from V2.2 Battery type Battery type Unsigned8 from V2.2 Order number Order number VisibleString(19) from V2.2 Serial number Serial number VisibleString(15) from V2.2 Manufacturing date Manufacturing date 3 x Unsigned8 from V2.2 Version number Version number 2 x Unsigned8 from V2.2 0x0020: State information (reading) Data Description Data type Remaining buffer time [1 s] Probable remaining buffer time. The remaining buffer time is calculated based on the present battery charge and the average current over a 10 minute period. Unsigned32 Total operating time [1 h] Total operating time. Unsigned32 Total calculated battery capacity [0.1 Ah] Total calculated battery capacity Unsigned16 Calculated battery 1 capacity [0.1 Ah] Battery 1: Calculated battery capacity Unsigned16 Calculated battery 2 capacity [0.1 Ah] Battery 2: Calculated battery capacity Unsigned16 Calculated battery 3 capacity [0.1 Ah] Battery 3: Calculated battery capacity Unsigned16 Calculated battery 4 capacity [0.1 Ah] Battery 4: Calculated battery capacity Unsigned16 Calculated battery 5 capacity [0.1 Ah] Battery 5: Calculated battery capacity Unsigned16 Calculated battery 6 capacity [0.1 Ah] Battery 6: Calculated battery capacity Unsigned16 Input voltage [0.01 V] Input voltage: Measured rms value of the supply voltage at the input of the SITOP UPS1600. Unsigned16 Input current [5 mA] Current measured at the input of the SITOP UPS1600. Unsigned16 Output voltage [0.01 V] Voltage measured at the output of the SITOP UPS1600. Unsigned16 Load current [5 mA] Load current measured at the output of the SITOP UPS1600. Unsigned16 Measured charge current [1 mA] Measured battery charge current of the SITOP UPS1600. Unsigned16 Battery voltage [0.01 V] Measured battery voltage of the connected battery modules Unsigned16 Output current [5 mA] Load current measured at the output of the SITOP UPS1600. Unsigned16 Charge voltage [0.01 V] Voltage used to charge the batteries during the constant charging process. Unsigned16 Fill byte(s) - 3 x Unsigned8 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 105 Engineering and remote access 3.5 Cyclic and acyclic data Data Description Valid configuration Valid configuration: Indicates whether the software parameters or Unsigned8 the parameters at the rotary switches are used. The corresponding setting should be made at the rotary switch for the buffer threshold. Data type Number of batteries Number of connected battery modules. Here, only the SITOP UPS1100 battery modules (coded batteries) are counted. Unsigned8 Fill byte(s) - 7 x Unsigned8 Battery 1 change recommended Battery 1: Battery replacement recommended: The battery capacity is not sufficient for the defined buffer time. Unsigned8 Battery 2 change recommended Battery 2: Battery replacement recommended: The battery capacity is not sufficient for the defined buffer time. Unsigned8 Battery 3 change recommended Battery 3: Battery replacement recommended: The battery capacity is not sufficient for the defined buffer time. Unsigned8 Battery 4 change recommended Battery 4: Battery replacement recommended: The battery capacity is not sufficient for the defined buffer time. Unsigned8 Battery 5 change recommended Battery 5: Battery replacement recommended: The battery capacity is not sufficient for the defined buffer time. Unsigned8 Battery 6 change recommended Battery 6: Battery replacement recommended: The battery capacity is not sufficient for the defined buffer time. Unsigned8 Battery 1 Connection Fault Battery1: Connection fault Unsigned8 Battery 2 Connection Fault Battery 2: Connection fault Unsigned8 Battery 3 Connection Fault Battery 3: Connection fault Unsigned8 Battery 4 Connection Fault Battery 4: Connection fault Unsigned8 Battery 5 Connection Fault Battery 5: Connection fault Unsigned8 Battery 6 Connection Fault Battery 6: Connection fault Unsigned8 Battery 1 temperature [1 C] Battery 1: Battery temperature Integer8 Battery 2 temperature [1 C] Battery 2: Battery temperature Integer8 Battery 3 temperature [1 C] Battery 3: Battery temperature Integer8 Battery 4 temperature [1 C] Battery 4: Battery temperature Integer8 Battery 5 temperature [1 C] Battery 5: Battery temperature Integer8 Battery 6 temperature [1 C] Battery 6: Battery temperature Integer8 Device temperature [1 C] Temperature in the housing Integer8 LED pattern Status of LEDs 1 to 4 for the SITOP UPS1600 1) Unsigned8 1) Object structure LED pattern SITOP UPS1600 / UPS1100 106 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.5 Cyclic and acyclic data 0x0040: Identification value parameters (reading/writing) Data Description Data type Contact Name of the contact person. You can change the name to suit your requirements (maximum 22 characters). VisibleString(40) VisibleString(64) from V2.1 Location Location designation: Indicates the unique location of the SITOP UPS1600 (max. 22 characters). VisibleString(40) VisibleString(44) from V2.1 0x0041: Web server parameters (reading/writing) Data Description Data type WebserverEnabled Enable/disable the web server of the SITOP UPS1600: Unsigned8 AutoReloadEnabled from V2.1 ReloadTime from V2.1 * 0: disable * 255. enable Enable/disable automatic update: * 0: disable * 255. enable Update interval: * AutoLogout from V2.1 Unsigned8 0: Off * 5: 5s * 10: 10s * 20: 20s * 30: 30s * 60: 60s Enable/disable automatic logoff: * Unsigned8 Unsigned8 0: disable * 255. enable When automatic logoff is activated, the logged on user ("Guest" or "Admin") is automatically logged off when the SITOP UPS1600 web server is inactive for 15 minutes. HttpAccessEnable from V2.1 Fill byte(s) from V2.1 Enable/disable HTTP access: * 0: disable * 255: enable - Unsigned8 Unsigned8 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 107 Engineering and remote access 3.5 Cyclic and acyclic data 0x0042: OPC UA server (reading/writing) Data Description Data type OPCServerEnabled Activate/deactivate the OPC UA interface of the SITOP UPS1600: Unsigned8 OPCUnencrypdedAccessEnable OPCPort * 0: disable * 255: enable Activate/deactivate unencrypted access via the OPC UA interface of the SITOP UPS1600: * 0: disable * 255: enable Set port for OPC UA interface (1 to 65535) Unsigned8 Unsigned16 0x0043: NTP client parameters (reading/writing) Data Description Data type NTPServerEnabled Activate/deactivate NTP server: Unsigned8 from V2.2 * 0: disable * 255: enable Fill byte(s) - Unsigned8 from V2.2 NTPServer1 IP address of NTP server 1 Unsigned8 from V2.2 NTPServer2 IP address of NTP server 2 Unsigned8 from V2.2 NTPServer3 IP address of NTP server 3 Unsigned8 from V2.2 NTPServer4 IP address of NTP server 4 Unsigned8 from V2.2 0x0044: NTP client status parameters (reading) Data Description Data type Last synchronization time Time that the last synchronization took place VisibleString(20) from V2.2 Next synchronization time Time of the next planned synchronization VisibleString(20) from V2.2 0x0045: PROFINETSecurity (reading/writing) Data Description Data type DCPReadonlyIfConnected Setting for DCP write protection Unsigned8 from V2.2 Fill byte(s) - Unsigned8 from V2.2 SITOP UPS1600 / UPS1100 108 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.6 SITOP UPS Manager 3.6 SITOP UPS Manager Note Ensure that only the UPS Manager accesses the SITOP UPS1600. Note Install the current version of the SITOP UPS Manager so that you can use the full functional scope of the SITOP UPS1600. The installation file for the SITOP UPS Manager is available at no charge on the SITOP home page (http://www.siemens.com/sitop-ups1600) or directly (https://support.industry.siemens.com/cs/ww/en/view/75854607). 3.6.1 Functions of the SITOP UPS Manager You can fulfill the following tasks using the SITOP UPS Manager : Configuration of the SITOP UPS1600 uninterruptible power supply and the battery modules (see Chapter Configuring the SITOP UPS1600 (Page 119)) Protect a computer or a computer network provided by the uninterruptible power supply with the master-slave technique Data backup by controlled shutdown Alarm-controlled starting of any application (SMS, e-mail) New functions from V4.71: OPC UA server as non-proprietary software interface. Sitting IP address and name in the SITOP UPS1600. Identifying SITOP UPS1600 by flashing LED SF. By specifying additional applications and alarms, you define a comprehensive protection of your computer or computer network. The applications can be started depending on the following events: Supply voltage failure Restoration of the supply voltage State of the buffer readiness by the UPS: - General buffer readiness - Remaining buffer time Status of the UPS battery: - Battery replacement required - Battery charge SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 109 Engineering and remote access 3.6 SITOP UPS Manager 3.6.2 The user interface of the SITOP UPS Manager Tabs for selecting the submenus Language selection Save bar Connection lamps Use the tab to reach the individual submenus. The language selection is used to select the user interface language of the SITOP UPS Manager. The German, English, French, Italian, Spanish, and Chinese languages are available. You use the functions of the save bar to load the configuration into or from the SITOP UPS1600 - and open or save the configurations to a data medium. The colors of the connection lamps indicate the status of the incoming and outgoing connection. Both lamps must light green. Left-hand connection lamp: Connection status SITOP UPS Manager application - SITOP UPS Manager service Right-hand connection lamp: Connection status SITOP UPS Manager service - SITOP UPS1600 SITOP UPS1600 / UPS1100 110 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.6 SITOP UPS Manager 3.6.3 Installation/uninstallation The installation file for the SITOP UPS Manager is available at no charge on the SITOP home page (http://www.siemens.com/sitop-ups1600) or directly (https://support.industry.siemens.com/cs/ww/en/view/75854607). Operational requirements Operating systems The Windows XP and Windows 7 (32 bit and 64 bit) operating systems are supported. Ethernet or USB interface To install and use the SITOP UPS Manager in conjunction with the SITOP UPS1600, the computer must be connected with the SITOP UPS1600 via Ethernet or USB port. Windows user group Users of the SITOP UPS Manager must be members of the Windows user group "power users". Installation preconditions Administration rights You require administrator rights to install the SITOP UPS Manager. Installation paths without blanks Note Paths must not contain any blanks! The path names of the directories for SITOP UPS Manager and batch files must not contain any blanks. Installation steps Procedure when installing for the first time 1. Close all applications before you start the installation. 2. Double-click on the "Setup_SITOP-UPSManager_x.xx.x" file. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 111 Engineering and remote access 3.6 SITOP UPS Manager 3. Follow the installation instructions. Enter the requested information in the dialogs: - Installer language, English or German - Agreement declaration with the license conditions - Installation scope: Activate option "USB driver" if your SITOP UPS1600 has a USB interface. You can select between application and service. - Installation path: Use the recommended target directory "C:\Program Files\x68\SITOPUPSManager" or select another one. If you select another target directory, please note that spaces are not permissible in the path name (to be taken into consideration up to version 4.61). - Start menu folder Select the folder structure under which the SITOP UPS Manager should appear in the start menu. 4. If you are using a SITOP UPS1600 with USB interface, then connect the SITOP UPS1600 to the computer using this interface. 5. Click "Finish" to complete the installation. Procedure for an already existing installation Note The procedure described below is only necessary if a SITOP UPS Manager with version number less than 4.50 is to be installed. These steps are automatically executed for versions from V4.50 and higher. 1. Back up the file "dcups.ini", which is located in directory "ini" in the installation directory of the SITOP UPS Managers. 2. Carry out steps 1 to 5 of the procedure described above when installing for the first time. 3. Replace file "dcups.ini", which is located in directory "ini" in the installation directory of the SITOP UPS Managers, as a result of the file backed up in Step 1. Result After the successful installation, the SITOP "UPS Manager" is contained in the start menu under the selected start menu folder. No further installations are required to operate the SITOP UPS Manager. Uninstallation The UPS Manager can be uninstalled using "Start All programs SITOPUPS Manager Uninstall". SITOP UPS1600 / UPS1100 112 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.6 SITOP UPS Manager 3.6.4 Options of establishing a connection to the SITOP UPS1600 Depending on the type, the SITOP UPS1600 provides either a USB interface or an Ethernet interface. Depending on the type, the SITOP UPS1600 communicates via USB or Ethernet with the SITOP UPS Manager. The SITOP UPS Manager supports the master-slave operation only for an existing Ethernet connection. This permits, for example, a controlled shutdown of the computers in the network by the applications started with the SITOP UPS Manager. 3.6.5 Establishing a connection via Ethernet The SITOP UPS1600 requires an IP address for communication with the UPS Manager. This is assigned by the network administrator. Use the Primary Setup Tool to configure the SITOP SITOP UPS1600 interface. Configuring the SITOP UPS1600 with the Primary Setup Tool The Primary Setup Tool is a Siemens product that is free of charge, and which is used to identify and configure network-capable devices. You can download the Primary Setup Tool at (http://support.automation.siemens.com/WW/view/en/19440762). From SW Version V2.1.0, the Primary Setup Tool is already integrated in the UPS Manager (from Version V4.71.x). The following procedure is then required: "Device configuration" tab Select network adapter Device configuration DC-UPS Update list Additional information is contained in the Primary Setup Tool manual. This manual and further links can be found at (http://support.automation.siemens.com/WW/view/en/19440762). Preconditions The SITOP UPS1600 is connected with the client (PG/PC) via the Ethernet interface. The Primary Setup Tool is installed on the client. Firewall settings that are necessary: - Communication via 5000 is permitted. - Echo request (ping) is permitted. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 113 Engineering and remote access 3.6 SITOP UPS Manager Procedure 1. Start the Primary Setup Tool. 2. Select the "Settings > Select interface" menu command. The "Set PG/PC interface" dialog opens. 3. Select the interface with which the client is connected with the SITOP UPS1600. Click "OK" to close the "Set PG/PC interface" dialog. SITOP UPS1600 / UPS1100 114 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.6 SITOP UPS Manager 4. Select the menu command "Network > Search". SITOP UPS1600 appears in the tree view as "DC-UPS :" with its MAC address and its IP address. 5. Open the SITOP UPS1600 entry and select "Ind. Ethernet interface". In the right-hand section, the configuration menu for the Ethernet interface of the SITOP UPS1600 opens. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 115 Engineering and remote access 3.6 SITOP UPS Manager 6. Configure the Ethernet interface as specified by the network administrator. 7. Select the SITOP UPS1600 in the Tree view. Loading to the device is not possible while an interface is selected. 8. Select menu command "Module > Download", to load the configuration to the device. Alternatively, you can start loading using the "Load" button in the toolbar. Configuring the connection in the SITOP UPS Manager A basic setting is the configuration of the client (PC/PG) as master or slave. The consideration of possible application situations can help here: The local computer is the only computer at the SITOP UPS1600. Local computer = master PC The local computer is one of several computers and performs the master function. Local computer = master PC The local computer is one of several computers at the SITOP UPS1600 and operates as slave. Local computer = slave PC In the master-slave configuration, the SITOP UPS1600, the master PC and the slave PC are connected at the same physical Ethernet. Only the master PC communicates directly with the SITOP UPS1600. The slave PC receives the control signals from the SITOP UPS Manager of the master PC. Note Up to SITOP UPS Manager Version 4.12, the master PC can only manage 1 slave PC. From version 4.12.5 and higher, up to 8 slaves can be managed. SITOP UPS1600 / UPS1100 116 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.6 SITOP UPS Manager Configuring the local computer as master PC 1. Select "General settings > Device configuration". 2. Activate the "Ethernet" checkbox and the "Master-PC" checkbox. 3. If the message appears as to whether you wish to restart the SITOP UPS Manager, confirm this with "Yes". The SITOP UPS Manager is restarted. 4. Select "Hardware configuration > Ethernet configuration". 5. Enter the IP address of the master PC in the field "IP address of the master PC". A selection box is displayed next to field "IP address of the master PC", which lists all of the available IP addresses of the client (PC/PG). Selecting an IP address automatically inserts this address in field "IP address of the master PC". Note Also at the local computer, the IP address of the master PC must be specified in the SITOP UPS Manager if a master-slave configuration is to be used. 6. Enter the IP address of the SITOP UPS1600 in the "IP address of the DC-UPS" field. 7. If the message appears as to whether you wish to restart the SITOP UPS Manager, confirm this with "Yes". The SITOP UPS Manager is restarted. The connection lamps light up green, the connection as master PC to the SITOP UPS1600 is established, if the (local) PC is connected as master PC to the SITOP UPS1600. Configuring the client as slave PC 1. Select "General settings > Device configuration". 2. Activate the "Ethernet" checkbox and the "Slave PC" checkbox. 3. If the message appears as to whether you wish to restart the SITOP UPS Manager, confirm this with "Yes". The SITOP UPS Manager is restarted. 4. Select "Hardware configuration > Ethernet configuration". 5. Enter the IP address of the master PC in the field "IP address of the master PC". 6. If the message appears as to whether you wish to restart the SITOP UPS Manager, confirm this with "Yes". The SITOP UPS Manager is restarted. The connection lamps light up green, the connection as slave PC to the master PC is established, if the (local) PC is connected as master PC to the SITOP UPS1600. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 117 Engineering and remote access 3.6 SITOP UPS Manager 3.6.6 Establishing a connection via USB 1. Connect the SITOP UPS1600 using a USB cable with the client (PC/PG). 2. Select "General settings > Device configuration". 3. Activate the "USB (UPS1600)" checkbox. 4. If, in the lower area, a blue bar with the message "Configuration changed, restart application now." appears, click on the bar to restart the UPS. Clicking on "x" only minimizes the UPS Manager. You can maximize the UPS Manager again by clicking on the associated symbol in the task bar. The SITOP UPS Manager is restarted. 5. Check that the connection lamps light green. The connection lamps light green, the connection to the SITOP UPS1600 via USB has been established, if the (local) PC is connected as master PC to the SITOP UPS1600. 3.6.7 Configuration in the SITOP UPS Manager Once you have connected the SITOP UPS1600 and the SITOP UPS Manager, you have the following configuration options: Create a new configuration. Load a configuration from a data medium or from a device. Change a configuration. Store a configuration on a data medium or load it into a device. Procedure 1. Make the required hardware configuration in SITOP UPS Manager. 2. Click in the save bar "Configurations" on the "Download" button. The configuration is loaded to the SITOP UPS1600 . 3. Change the hardware configuration in the SITOP UPS Manager to address your specific requirements. 4. Click in the save bar "Configurations" on the "Download" button to transfer the configuration to the SITOP UPS1600. Click on "Save file", to save the configuration to a file. This means that you can restore the SITOP UPS1600 configuration at a later point in time - or transfer the configuration to other devices. SITOP UPS1600 / UPS1100 118 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.6 SITOP UPS Manager Note When saving or loading a HW configuration, the entry in "Base unit > Location" is not accepted/changed. 3.6.7.1 General settings Under "Software configuration > General settings", specify the maximum size of the log file in Kbytes and where it is saved. From SITOP UPS Manager V4.12.5 and higher, under "Software configuration > General settings" you can also specify as to whether the window of the SITOP UPS Manager should always be in the foreground. Log file 1. Select "Software configuration > General settings". 2. Enter the maximum file size in kbytes in the "Size of log file" dialog box. 3. Click on "Browse" 4. Select the directory in which the log file should be stored. 5. Confirm with "Select folder". The maximum size and the storage location of the log file has been saved. 3.6.7.2 Configuring the SITOP UPS1600 Using the SITOP UPS Manager, you can configure the SITOP UPS1600 and its energy storage device, and then load to the device (if it is an uncoded battery - for UPS1100, the values are automatically identified). To change the charge parameters switch-in threshold or buffer time, you must set the corresponding rotary coding switch to the "REN" position. 1. To do this, select "Hardware configuration > Base device" or "Hardware configuration > Energy storage". 2. Enter the desired values. 3. Click on "Download" Configuring the basic device (base unit) The following parameters are available under "Hardware configuration> Base unit". Parameter Value range Default setting Location Free text - Connection threshold 21 - 25 V 22.5 V 1 - 32767 s 600 s Yes / No No Buffer time Maximum buffer time 1) SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 119 Engineering and remote access 3.6 SITOP UPS Manager Parameter Value range Default setting Additional buffer time after the PC was powered down 3) 1 - 300 s 60 s Expected buffer current 0 - 40 A 0A Reset time 1 - 120 s 5s Enable reset after buffering Yes / No No Downtime alarm 0 - 20000 ms 100 ms Wait time for stable input voltage 0.2 - 65 s 1.0 s R test interval 1 - 65535 h 4h 1) 2) 1) Parameter only available from V2.0.0 and higher 2) Parameter only available from V2.1 and higher 3) valid from V2.0.4 or V2.1 Location: Details of the location identification where the SITOP UPS1600 is installed. Connection threshold: If the connection threshold value is fallen below, the SITOP UPS1600 starts buffering. If the value of the connection threshold is reached or undershot again later, the SITOP UPS1600 stops buffering. Buffer time: Length of time during which the system should be buffered by the SITOP UPS1600. Maximum buffer time: The MAX setting means that buffering is realized for as long as possible. The device only shuts down when the battery has discharged down to the defined stop buffering voltage. The value entered for the "Buffer time" parameter is not relevant in this case. Additional buffer time after PC shutdown: The time in which the system is buffered by the SITOP UPS1600 once the PC has been shut down. Expected buffer current: Load current, which is expected at the device output during buffer operation. Please adjust the correct application load current required. For current settings between 0 A and rated current, the display in the diagram "Remaining buffer time" is adapted. If a value of 0 A is entered, then for this parameter, the average value of the actual load current measured at the output over the last 10 min is assumed. The value of this parameter is used when calculating the remaining buffer time. The entered value may not exceed the rated device current. Note From the instant in time when the SITOP UPS1600 is switched over into the buffer mode, to determine the expected buffer time, instead of the expected buffer current, the actually measured buffer current is used. Reset time: Time, in which the output voltage of the SITOP UPS1600 is switched off, although in the meantime the input voltage has returned. This function allows IPCs to automatically restart. Enable reset time after buffering: If the value is set to "Yes", the SITOP UPS1600 shuts down the output for the selected interrupt time if, in the meantime, the input voltage returns after the buffer time has expired. Using this function, after the SITOP UPS1600 has been powered down, an IPC can be switched on again, for example. SITOP UPS1600 / UPS1100 120 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.6 SITOP UPS Manager Downtime alarm: The time in which no alarm is issued to the system although it is buffered. Wait time for stable input voltage: The time in which no alarm is issued to the system although the connection threshold has been undershot. R test interval: The time interval between battery tests can be set using the parameter. To reset the parameters to their initial value, click the "Reset to initial values" button. All parameters for the base device will be reset to their initial value. Configuring the energy storage The characteristic values of a SITOP UPS1100 battery module are automatically read by the coding. If a SITOP UPS1100 battery module is used, activate the "SITOP UPS1100 battery" checkbox. If you are using a different battery, activate the "Use third-party battery" checkbox. Enter the rated values of the other battery. The following parameters are available under "Hardware configuration> Energy storage". Parameter Value range Battery capacity 0.1 - 3,200 Ah End-of-charge voltage 24 - 30 V Charge current 0.001 - 5 A Faulty battery voltage 1 - 18 V Battery capacity: Total capacity of the installed batteries End-of-charge voltage: The charging completes when the selected end-of-charge voltage is reached. Charge current: The battery is not charged with more than the selected charge current. The manufacturer's details for the permitted charge current of the battery must be observed. If several batteries are connected, the smallest permitted charge current applies. Faulty battery voltage: If the battery voltage falls below this value, it will be considered as being defective by the SITOP UPS1600 and is not charged. To reset the parameters to their initial value, click the "Reset to initial values" button. All parameters for the energy storage will be reset to their initial value. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 121 Engineering and remote access 3.6 SITOP UPS Manager 3.6.8 Behavior of the SITOP UPS Manager The monitoring of the uninterruptible power supply by the SITOP UPS Manager permits other applications to be started event driven. In the event of a power failure, the SITOP UPS Manager can use the network to perform a controlled shutdown of the devices connected to the uninterruptible power supply in the specified order, or place them in a defined standby state. Alarms and notifications can also be sent to the system or to users (SMS, e-mail). The applications can be started depending on the following events and factors: Power failure Power return State of the buffer readiness by the SITOP UPS1600: - General buffer readiness - Remaining buffer time State of the SITOP UPS1600 battery: - Battery charge - for recommended battery replacement State of the communication interface: - Connection established/interrupted System alarm status - At least one alarm is active/no longer active Storing an application In the various submenus, you can store applications that will be started depending on the above-mentioned events and factors. Examples of such applications are: Batch scripts or runnable files, for example, to shut down a computer in the network. Applications that inform the user about the state of the power supply. Applications that protect licenses assigned to computers (floating licenses) from being lost because of power failure. Procedure 1. Open the appropriate submenu under "Software configuration". 2. Activate the checkbox to start the application for the desired event. 3. Click on "Browse" to select an application. 4. Select the required application in a directory. The application path is displayed. SITOP UPS1600 / UPS1100 122 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.6 SITOP UPS Manager 5. To check whether the application will performed correctly, click the "Start" button. 6. Enter the time in minutes and seconds after which the application should be started. Note It is recommended that only applications without user interface - or those that automatically exit themselves without any manual intervention - are started. Behavior during buffer mode Make the settings under "Software configuration > Buffer operation" vor. The following options are available: Start application on power failure. Start application after power return. Show SITOP UPS Manager on power failure. Show SITOP UPS Manager after power return. Shut down PC on power failure. NOTICE If the buffer time (see Section Configuring the SITOP UPS1600 (Page 119)) is set shorter than this time, the SITOP UPS1600 switches off before the PC has been shut down. The PC is then no longer protected. In master-slave operation, the time required to run down the master must be longer than the time required for the slave. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 123 Engineering and remote access 3.6 SITOP UPS Manager Use the "upsshutdown.exe" program After installing UPS-Managers (from version V4.71 and higher), file "upsshutdown.exe" is located under the following path: C:\Users\Public\Documents\SitopUPSManager\commands\shutdown SITOP UPS1600 / UPS1100 124 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.6 SITOP UPS Manager In the settings for the UPS Manager under SW configuration, activate the following: 1. Activate "Switch off UPS after manual shutdown"under "General settings" 2. Under buffer operation, activate "Start application on power failure" and specify the path to your batch data, e.g. to C:\Users\Public\Documents\SitopUPSManager\commands\shutdown\runupsshutdown.ba t. (adapt to the specific requirements) 3. Under buffer operation, deactivate "Shut down PC on power failure" SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 125 Engineering and remote access 3.6 SITOP UPS Manager Description of the program arguments "upsshutdown.exe": upsshutdown.exe -[c][r][s] c: PC is shut down s: S command is sent to the UPS. The UPS is shut down without any additional delay. r: R command is sent to the UPS. After the PC has been shut down (no response to ping), the UPS shuts down after waiting for time "Additional buffer time after PC shutdown". Example for runupsshutdown.bat: @echo off set var = C:\Users\Public\Documents\SitopUPSManager\commands\shutdown echo "% var %" cd "% var %" dir > info.txt upsshutdown.exe -cr Behavior for missing buffer readiness Make the settings under "Software configuration > Not ready for buffering". The following options are available: Start the application if buffer mode is not possible. Start the application when buffer readiness returns Open the SITOP UPS Manager if buffer mode is not possible Open the SITOP UPS Manager when buffer readiness returns. SITOP UPS1600 / UPS1100 126 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.6 SITOP UPS Manager Behavior when battery replacement required Make the settings under "Software configuration > Battery replacement". The following options are available: Start the application if battery replacement is recommended (from SITOP UPS Manager V4.12.5 and higher). Start the application once the battery has been replaced. Open the SITOP UPS Manager if battery replacement is recommended (from SITOP UPS Manager V4.12.5 and higher). Open the SITOP UPS Manager once the battery has been replaced. Behavior depending on the battery charge Make the settings under "Software configuration > Battery charge". The following options are available: Start the application when the battery charge is > 85 % of the maximum. Start the application when the battery charge is < 85 % of the maximum. Open SITOP UPS Manager when the battery charge is > 85 % of the maximum. Open SITOP UPS Manager when the battery charge is < 85 % of the maximum. Note From UPS Manager Version V4.71, a percentage value of the battery charge can be programmed where an action should be initiated. Behavior depending on the remaining buffer time Make the settings under "Software configuration > Remaining buffer time". Specify the minimum buffer time under "Hardware configuration > Base Unit" in entry "Buffer time". The following options exist in the "Remaining buffer time" submenu: Start the application if the desired buffer time cannot be achieved. Start the application if the desired buffer time can be achieved again. Display the SITOP UPS Manager if the desired buffer time cannot be achieved. Display the SITOP UPS Manager if the desired buffer time can be achieved again. Response when communication to the SITOP UPS1600 is interrupted Make the settings under "Software configuration > Communication interface". The following options are available: Start the application if there is a connection to the SITOP UPS1600. Start the application if the connection to the SITOP UPS1600 is interrupted. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 127 Engineering and remote access 3.6 SITOP UPS Manager Open the SITOP UPS Manager if there is a connection to the SITOP UPS1600. Open the SITOP UPS Manager if the connection to the SITOP UPS1600 was interrupted. Behavior for pending system alarms Make the settings under "Software configuration > System alarms". Reasons for a system alarm are contained in the alarms list (see Section Troubleshooting (Page 183)). The following options exist in the "System alarms" submenu: Start the application if at least one system alarm is active. Start the application if no system alarm is active. Open the SITOP UPS Manager if at least one system alarm is active. Open the SITOP UPS Manager if no system alarm is active. 3.6.9 Display and visualization The "Display" menu item shows information about the device data and parameters as well as the state of the power supply. The following display options exist: Active alarms Alarm history Operating data: Data and parameters of the basic device and the energy storage device Trend charts: - Load current over time - Input voltage over time - Remaining buffer time over time Note From the instant in time when the SITOP UPS1600 is switched over into the buffer mode, to determine the expected buffer time, instead of the expected buffer current, the actually measured buffer current is used. - Battery temperature over time - Battery charge over time - Charge current over time Online functions: - Updating the firmware SITOP UPS1600 / UPS1100 128 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.6 SITOP UPS Manager Displaying pending alarms 1. Select "Display > Pending alarms". The pending alarms are displayed in a tabular form. The individual columns contain the following information: Name: A descriptive name of the alarm Time: The time and date of the alarm arrival Help: Description of the alarm Displaying the alarm history 1. Select "Display > Alarm history". The alarm history is displayed in a tabular form. The individual columns contain the following information: Name: A descriptive name of the alarm Time: The time and date when the alarm comes and goes Alarm: - incoming: Occurrence of the alarm event - outgoing: Rectification of the alarm event Data and parameters SITOP UPS1600 1. Select "Display > Operating data". 2. Under "Base Unit" you can find data and parameters of the SITOP UPS1600. The following data are displayed: Order number Serial number SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 129 Engineering and remote access 3.6 SITOP UPS Manager SW version HW product version The following parameters are displayed: Buffer mode Remaining buffer time Note From the instant in time when the SITOP UPS1600 is switched over into the buffer mode, to determine the expected buffer time, instead of the expected buffer current, the actually measured buffer current is used. Input voltage Load current Ready for buffering Energy storage data and parameters 1. Select "Display > Operating data". 2. The data and parameters of the energy storage device can be found under "Energy storage". The following data are displayed: Order number Serial number SW version The following parameters are displayed: Battery capacity Battery charge level Battery temperature Measured charge current SITOP UPS1600 / UPS1100 130 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.6 SITOP UPS Manager Trend charts You have the possibility of graphically displaying values about the power supply under "Display> Trend chart", for instance the load current over time: The following trend charts can be selected: Load current over time Input voltage over time Remaining buffer time Note From the instant in time when the SITOP UPS1600 is switched over into the buffer mode, to determine the expected buffer time, instead of the expected buffer current, the actually measured buffer current is used. Battery temperature over time Battery charge over time Charge current over time SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 131 Engineering and remote access 3.6 SITOP UPS Manager Procedure 1. Select "Display > Trend diagram". 2. Select "Base Unit" to display trend diagrams for SITOP UPS1600 values or select "Energy storage" to display trend diagrams for the energy storage device values. 3 diagrams are available below both points. 3. Click the appropriate button to display the required trend diagram. 3.6.10 Determining the firmware version The firmware version of the SITOP UPS1600 can be determined as follows using the UPS Manager: Precondition The SITOP UPS1600 is connected to your PC via USB. Also possible for a connection via Ethernet with software version> V2.0 - and manager version > 4.60.1 SITOP UPS1600 / UPS1100 132 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.6 SITOP UPS Manager Procedure 1. Start the UPS Manager. 2. Using the menu command "Display > Operating data > Base unit" the firmware version of the SITOP UPS1600 is displayed. In the example shown, firmware version V2.0.1 is installed on the SITOP UPS1600. 3.6.11 Firmware update WARNING The SITOP UPS1600 is reset while updating the firmware. For safety reasons, the output is switched off. Ensure that no damage is caused to the plant or system. Ensure that the PG/PC and/or all switches, routers and gateways that are used have an independent power supply during the firmware update. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 133 Engineering and remote access 3.6 SITOP UPS Manager WARNING Firmware update with UPS-Manager If for the firmware update, the UPS Manager is used, please note that for a firmware update from version V2.1 to V2.2 or higher, then a UPS Manager with version V4.72 or higher must be used. This also applies to firmware updates from V2.2.0 to higher versions. Note Install the current version of the SITOP UPS Managers, before you start the firmware update. It is possible that an older version (less than V4.5X) of the SITOP UPS Managers does not support this firmware update. The installation file for the SITOP UPS Manager is available at no charge on the SITOP home page (http://www.siemens.com/sitop) or directly (https://support.industry.siemens.com/cs/ww/en/view/75854607). Note Do not switch-off the devices during the firmware update. The files for updating the firmware (firmware updates) are available online under (http://support.automation.siemens.com/WW/view/en/79207181). Different firmware updates are offered depending on the amp rating of the SITOP UPS1600. Note Observe the compatibility of the firmware! Other firmware updates are not compatible. Determine the amp rating of your SITOP UPS1600 and download the appropriate firmware update. Note It is not possible to downgrade the device firmware to a release with a version number lower than the firmware installed in the device itself. Information on how to read out the firmware release from the device is provided in Section Determining the firmware version (Page 132). Note "Reset to Factory" function: All configuration parameters are reset to the default setting; 0.0.0.0 is used for the IP address. A new IP address must then be assigned, as otherwise there is no connection to the UPS Manager or TIA Portal. See also Display and visualization (Page 128) SITOP UPS1600 / UPS1100 134 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.7 Web server Preconditions The SITOP UPS1600 has been correctly connected and linked with the system. PG/PC with SITOP UPS Manager is connected with the system. Procedure 1. Select "Display > Online functions". 2. Select "Update firmware". 3. To select the path to the directory with the unzipped files, click on the "Browse" button. In this directory, select the "ups10a.upd", "ups20a.upd" or "ups40a.upd" file. 4. Click on the "Start" button. The firmware is updated. 5. A message appears in the window area after the successful update. 6. Manually restart the SITOP UPS1600 by interrupting the SITOP UPS1600 power supply. Restore the power supply to the SITOP UPS1600. The firmware update has been performed successfully. 3.7 Web server The web server is used to monitor the SITOP UPS1600. It operates independently of UPS Manager and PROFINET access. New functions of the web server from V2.1 and higher: Write access User administration Access via https 3.7.1 Accessing the web server A Web browser is used for the access and operation. The following Web browsers are suitable: Internet Explorer V8 (on MS Windows XP) Internet Explorer V10 (on MS Windows 7) Internet Explorer V11 (on MS Windows 7) Mozilla Firefox from V40 (on MS Windows 7) Google Chrome from V44 (on MS Windows 7) SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 135 Engineering and remote access 3.7 Web server Preconditions The computer with installed web browser is connected with the SITOP UPS1600 via Ethernet. The Web browser can display SVG graphics. From version V2.1 and higher, it is no longer necessary that SVG graphics are supported. If your web browser cannot display SVG graphics, then "Please install the SVG viewer for a correct display" message appears on the start screen. To permit the correct display, perform the following steps: - Download the SVG update at (http://www.savarese.com/software/svgplugin). - Install the SVG update. - If required, restart your computer. The SITOP UPS1600 has an IP address that you know. Web server access is activated. The following sections explain how to activate access to the web server: - For SIMATIC STEP 7 in the TIA Portal at Parameterizing the UPS1600 (Page 58). - For SIMATIC STEP 7 at Parameter assignment (Page 77). - Users without SIMATIC STEP 7, must proceed as follows (for software version V2.1.1): Device in the state when supplied: 1. Turn both rotary coding switches into the REN and OFF positions. 2. Switch the device off and on again. Please wait approximately 1 minute as a new certificate is created due to the IP address change. The device can now be accessed via https://192.168.20.220. 4. Login with name "admin" and password "admin". 5. Under "HW Configuration -> General -> Web server -> Settings" the web server must be permanently activated. ("Activate web server on this module"). 6. Under "HW Configuration -> General -> Communication interface", IP address, subnet mask and router address can be set. 7. To transfer changes to the device, the "Download to device" button must be pressed. 8. Now turn the rotary coding switches to the required position and switch the device off and on again. Please wait approximately 1 minute as a new certificate is created due to the IP address change. The device can now be accessed at the new IP address. If the IP address was already changed, then the state when originally shipped must be restored. You can do this, for example, using the Primary Setup Tool and function "Reset" under "Module" - or using the PRONETA tool and function "Reset network parameters". - Users without SIMATIC STEP 7, must proceed as follows (from software version V2.1.2 and higher): 1. Turn both rotary coding switches into the REN and OFF positions. The device is now accessible via https://192.168.20.220 (if the device was SITOP UPS1600 / UPS1100 136 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.7 Web server previously in the state when originally shipped with IP address 0.0.0.0) - or using the already set IP address. Under certain circumstances you must wait approximately 1 minute because a new certificate must be created due to the IP address change. 3. Login with name "admin" and password "admin". 4. Under "HW Configuration -> General -> Web server -> Settings" the web server must be permanently activated. ("Activate web server on this module"). 5. Under "HW Configuration -> General -> Communication interface", IP address, subnet mask and router address can be set. 6. To transfer changes to the device, the "Download to device" button must be pressed. Under certain circumstances you must wait approximately 1 minute because a new certificate must be created due to the IP address change. 7. Now turn the rotary coding switches to the required position. The device can now be accessed at the previously set IP address or the new IP address. Procedure 1. Connect the client (PG, PC) via the PROFINET interface with the CPU. 2. Open the web browser. In the address dialog box of the web browser, enter the IP address of the SITOP UPS1600 in the form http://ww.xx.yy.zz (input example: http://192.168.0.14). The start page of SITOP UPS1600 is opened. You can navigate to further menus from the start page. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 137 Engineering and remote access 3.7 Web server 3.7.2 The web server user interface Menu selection Navigation submenus "License information" button "Logout" button Language selection "Download to device" button Editor area The menu selection allows you to access menus "Diagnostics" and "HW configuration" and the various submenus. The functions of the menus are described in the following sections. You access the submenus from the navigation submenus . The associated settings possible in the selected submenu are made in the editor area . You load the configuration to the devices by pressing button . The language selection is used to select the user interface language of the web server. The German, English, French, Italian, Spanish, and Chinese languages are available. Click on the "Logout" button to log out from the current web server session. The web server can only be accessed by logging in again. You can download the license information of the UPS1600 system using the "License information" button. SITOP UPS1600 / UPS1100 138 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.7 Web server Grayed out menus If the SITOP UPS1600 was assigned a SIMATIC S7 control as I/O device, or the SITOP UPS Manager is connected to the SITOP UPS1600, then the web server is in the read-only mode. The following applies in the read-only mode: No write access is possible; the parameter settings can only be read (input values shown in gray, valid for software version up to V2.0) Firmware cannot be updated, the item is hidden. 3.7.3 Functions of the web server The functions of the web server are split up between the two menus "Diagnostics" and "HW Configuration". Use the "Download to device" function to load changes that you have made to the device, see Loading the configuration (Page 141). Diagnostics You can find the following submenus here: Alarms: For an overview of past and active alarms, see Alarm monitoring (Page 141). Operating data: For an overview of the operating data, see View the data of the SITOP UPS1600 (basic device) (Page 143) and Viewing the energy storage data (Page 144) Online functions with the options: - Firmware update - Reset to factory setting For the online functions, see Online functions (Page 145). HW configuration Here, in the following areas you can make changes: Configuring the PROFINET interface, see General (Page 146) Changing the web server settings, see Web server (Page 148) Configuring the OPC UA interface, see OPC UA server (Page 149). Making PN security settings, see Improved PN security (Page 151). Managing users, see User administration (Page 151). Configuring basic devices and energy storage devices, see Device configuration (Page 153) You can save the configurations and load the existing configurations into the device, see Load / Save (Page 157). SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 139 Engineering and remote access 3.7 Web server 3.7.4 Determining the firmware version The firmware version of the SITOP UPS1600 can be determined as follows via Ethernet using the web server: Using the menu command "Diagnostics > Operating data > Base unit" the firmware version of the SITOP UPS1600 is displayed. In the example shown, firmware version V2.2.0 is installed on the SITOP UPS1600. 3.7.5 Firmware update with web server Precondition The SITOP UPS1600 has been correctly connected and linked with the system. PG/PC with the actual web browser is connected to the system and is logged on. SITOP UPS1600 / UPS1100 140 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.7 Web server Note Administrator rights for the web server are required in order to update the firmware. Procedure 1. Select "Diagnostics > Online function > Firmware update" 2. Click on button "Select file". Select the appropriate update file. 3. Click on button "Run update". Firmware update starts. A message is displayed after the successful update. 4. Manually restart the SITOP UPS1600 by interrupting the SITOP UPS1600 power supply. 5. Reconnect the SITOP UPS1600 power supply. The firmware update has been performed successfully. 3.7.6 Loading the configuration You can download the actual configuration from the web server directly to the device using the "Download to device" button. Procedure for saving the configuration 1. Click on the "OK" button to load the configuration. 2. Acknowledge the confirmation prompt. 3.7.7 Diagnostics 3.7.7.1 Alarm monitoring You can use the web server to obtain information about active alarms and the history of the alarms. Every alarm that concerns the SITOP UPS1600 and the connected battery modules is recorded. You can display active alarms using "Diagnostics > Alarms > Pending alarms". SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 141 Engineering and remote access 3.7 Web server Pending alarms The currently pending system alarms are provided in this list. Displaying the alarm history 1. Select menu "Diagnostics". 2. Select the "Alarm history" entry under "Alarms" in the navigation. The alarm history is displayed in a tabular form. The individual columns contain the following information: Name: A descriptive name of the alarm Date and time: The time and date when the alarm comes and goes Incoming/outgoing: - incoming: Occurrence of the alarm event - outgoing: Rectification of the alarm event Note The alarm history is displayed only when no further communications relationships to the SITOP UPS1600 have been established. Examples for further communications relationships are communication relationships via STEP 7 or the SITOP UPS Manager. SITOP UPS1600 / UPS1100 142 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.7 Web server 3.7.7.2 View the data of the SITOP UPS1600 (basic device) 1. Select menu "Diagnostics" 2. Select the "Base unit" entry under "Operating data" in the navigation. Here, you can find the following information: Data of the SITOP UPS1600: - Order number - Serial number - SW version - HW product version Operating mode (normal or buffer mode) Ready for buffering SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 143 Engineering and remote access 3.7 Web server Remaining buffer time Note From the instant in time when the SITOP UPS1600 is switched over into the buffer mode, to determine the expected buffer time, instead of the expected buffer current, the actually measured buffer current is used. Current input voltage Output voltage Load current 3.7.7.3 Viewing the energy storage data Figure 3-3 Diagnostics energy storage devices 1. Select menu "Diagnostics" 2. Select the "Energy storage" entry under "Operating data" in the navigation. Here, you can find the following information about the connected energy storage devices: Order number Serial number SW version HW product version Battery charge level Battery temperature Measured charge current Battery voltage SITOP UPS1600 / UPS1100 144 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.7 Web server 3.7.7.4 Online functions Firmware update The firmware update process is described in detail in the "Firmware update readme", which is provided with the firmware update download package. Follow the instructions provided there carefully. The files for updating the firmware are available online at: (https://support.industry.siemens.com/cs/ww/en/view/79207181) Refer also to Section Firmware update with web server (Page 140). Reset to factory settings A reset to the factory settings deletes all hardware and software configurations stored in the SITOP UPS1600 and restores the factory settings. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 145 Engineering and remote access 3.7 Web server This affects, for example: IP address Device name Parameter values for the SITOP UPS1600 and assigned supplementary modules. "Web server activated" setting. Web server is de-activated. Procedure 1. Select menu "Diagnostics". 2. Select submenu "Online functions". 3. Select entry "Reset to factory setting". 4. In the editor area, click on "Reset to factory settings". 5. Acknowledge the confirmation prompt with "OK". 3.7.8 HW configuration 3.7.8.1 General You have the following options under menu item "HW Configuration > General": Configuring the PROFINET interface Making settings for the web server Making settings for the OPC UA server Making settings for the NTP client Making settings for PROFINET security Managing users SITOP UPS1600 / UPS1100 146 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.7 Web server PROFINET interface You have the option of configuring the PROFINET interface regarding the following points: General I&M (identification & maintenance) - Defining the location ID - Defining the contact - Defining the device name Defining whether the IP address is dynamically assigned (activate DHCP) or whether it should be fixed. Procedure 1. Select the "Hardware configuration" menu. 2. Select submenu "General". 3. Select the "Communication interface" entry. 4. In the editor area, under "Device name" enter the required device name. 5. To dynamically assign the IP address: Activate checkbox "Source IP address via DHCP". SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 147 Engineering and remote access 3.7 Web server 6. To assign a fixed IP address: Activate checkbox "Fixed IP address" and enter the appropriate parameters in the editor area. 7. Load the data to the device, see Loading the configuration (Page 141). 3.7.8.2 Web server Here, you can make general settings and define which actions should be automatically executed. Settings Parameters Value range Default setting Activate web server on this module Yes/no No Permit access only with HTTPS Yes/no Yes Log off automatically after 15 minutes Yes/no No Update interval 0 / 5 s / 10 s / 20 s / 30 s / 60 s 0 = no automatic update Activate web server on this module Define as to whether the device may be accessed via the web server. Permit access only with HTTPS Define whether access is only permissible via HTTPS. SITOP UPS1600 / UPS1100 148 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.7 Web server Download certificate You can download the certificate for encrypted connection via HTTPS by pressing the "Download certificate" button. Log off automatically after 15 minutes Define whether a user should be automatically logged off after closing the web server. Update interval Define the interval in which the actual values are sent to the web server. 3.7.8.3 OPC UA server Here, you configure the OPC UA server. Settings SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 149 Engineering and remote access 3.7 Web server General OPC UA server activated Define as to whether device can be accessed via the OPC UA interface. If the option is activated, then the SITOP PSU8600 acts as OPC UA server. Unencrypted access activated If the option is activated, then unencrypted access via the OPC UA client is possible. Activating the option is not recommended. OPC UA server port The preset port number is 4840. You can enter another port number. 3.7.8.4 NTP client You configure the NTP client under "HW configuration > General > OPC UA server > Settings". If the NTP client is activated, then the local time is synchronized with the specified time of the specified NTP server. The NTP update interval is automatically and dynamically adapted between 64 seconds and 68 minutes 16 seconds. SITOP UPS1600 / UPS1100 150 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.7 Web server The time of the last synchronization and the next scheduled synchronization are displayed. NTP client activated Here, activate the NTP client. NTP server address 1 ... 4 Enter up to 4 IP addresses of NTP servers. 3.7.8.5 Improved PN security Settings Activate these options in order to protect the system against changes initiated externally. AR configuration locked DCP write protection activated 3.7.8.6 User administration You can access user administration under "HW configuration > General >Improved PN security > User administration ". SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 151 Engineering and remote access 3.7 Web server User administration Here, you can change the administrator password and set up the system so that guests can access the system - and up to 14 additional user accounts with different authorization levels. Procedure for changing the administrator password Note Users "admin" and "guest" are preset and cannot be deleted. 1. Select the "Hardware configuration" menu. 2. Select submenu "General > Improved PN security". 3. Select entry "User administration". 4. Enter the new password in the editor area, in line "admin" under "Password". Note The password must satisfy the following minimum requirements: * min. 8 characters * min. 1 uppercase letter * min. 1 lowercase letter * min. 1 digit * min. 1 special character The following characters are possible: ^[a-z0-9A-Z\\-_]+$ 5. Enter the new password again under "Confirm password". 6. Load the data to the device, see Loading the configuration (Page 141). SITOP UPS1600 / UPS1100 152 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.7 Web server Note For security reasons, when installing for the first time, the default password should be changed. Further, it is recommended that passwords are regularly changed. Procedure for setting up a guest access 1. Select the "Hardware configuration" menu. 2. Select submenu "General > Improved PN security". 3. Select entry "User administration". 4. Enter a password in the editor area under "guest" and select the individual access rights for guest access. 5. Enter the password again under "Confirm password". 6. Load the data to the device. Procedure for setting up a user account 1. Select the "Hardware configuration" menu. 2. Select submenu "General > Improved PN security". 3. Select entry "User administration". 4. In the editor area, click on "Add new user" and in this line enter the name for the new user. 5. Select the individual access rights for the new user. 6. Enter a password for the new user - and repeat this to confirm the password. 7. Load the data to the device. 3.7.8.7 Device configuration You set the parameters for basic devices and energy storage devices under menu item "HW Configuration > Device configuration". SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 153 Engineering and remote access 3.7 Web server Basic device configuration "Buffering" parameters Parameter Value range Initial value Connection threshold 21 - 25 V 22.5 V Buffer time 1 - 32767 s 600 s Maximum buffer time 1) Yes / No No 1 - 300 s 60 s 0 - 40 A 0A Additional buffer time after PC shutdown. 3) Expected buffer current 1) Reset time: Enable reset after buffering 1) Parameter only available from SW version V2.0 and higher 2) Parameter only available from SW version V2.1 and higher 3) Valid from V2.0.4 or V2.1 5s Yes / No No SITOP UPS1600 / UPS1100 154 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.7 Web server Switch-in threshold Setting the switch-in threshold. Buffer time Length of time during which the system should be buffered by the SITOP UPS1600. Maximum buffer time The setting means that buffering is realized for as long as possible. The device only shuts down when the battery has discharged down to the defined stop buffering voltage. The value entered for the "Buffer time" parameter is not relevant in this case. Additional buffer time after PC shutdown Time during which the system should be buffered by the SITOP UPS1600 after the PC was shut down. Expected buffer current Load current, which is expected at the device output during buffer operation. Please adjust the correct application load current required. For current settings between 0 A and rated current, the display in the diagram "Remaining buffer time" is adapted. If a value of 0 A is entered, then for this parameter, the average value of the actual load current measured at the output over the last 10 min is assumed. The value of this parameter is used when calculating the remaining buffer time. The entered value may not exceed the rated device current. Note From the instant in time when the SITOP UPS1600 is switched over into the buffer mode, to determine the expected buffer time, instead of the expected buffer current, the actually measured buffer current is used. Enable reset after buffering If the value is set to "Yes" then the output voltage is interrupted after the selected buffer time expires if, in the meantime, the input voltage returns. This option is useful, when, for example, computer networks are protected by the UPS that can be activated by a reset when the power supply is restored. For buffer time "MAX", the output voltage is not interrupted. "Signaling" parameter Parameter Value range Default setting Downtime alarm 0 - 20,000 ms 100 ms Wait time for stable input voltage 0.2 - 65 s 1s Downtime alarm The time in which no alarm is issued to the system although it is buffered. Wait time for a stable input voltage Time where the input voltage must continually lie above the connection threshold so that buffering is exited and a transition is made into normal operation. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 155 Engineering and remote access 3.7 Web server "Maintenance" Parameter Value range Default setting R test interval 1 ... 65535 h 4h R test: The battery state is determined by subjecting it to a cyclic load. Energy storage device configuration "Energy storage" has two different areas that depend on the battery type being used. First select whether you are using a SITOP UPS1100 battery module or some other energy storage. Using a SITOP UPS1100 battery module No additional parameterization. Using a different battery module Parameter Value range Default setting Battery capacity 0.1 - 3,200 Ah 10 Ah End-of-charge voltage 24 - 30 V 27.3 V Charge current 0.001 - 3 or 4 or 5 A 0.3 A Faulty battery voltage 1 - 18 V 6V Battery capacity Total capacity of the installed batteries. End-of-charge voltage Maximum voltage up to which the battery may be charged. Charge current The battery is not charged with more than the selected charge current. The SITOP UPS1600 / UPS1100 156 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.7 Web server manufacturer's details for the permitted battery charge current must be observed. Further, the following, device-dependent values apply: - SITOP UPS1600 10 A: Maximum permissible charge current 3,000 mA Derating for Tu > 40 C or Uin < 24 V: 2,000 mA - SITOP UPS1600 20 A: Maximum permissible charge current 4,000 mA Derating for Tu > 40 C or Uin < 24 V: 3,000 mA - SITOP UPS1600 40 A: Maximum permissible charge current 5,000 mA Derating for Tu > 40 C or Uin < 24 V: 3,000 mA Faulty battery voltage If the battery voltage falls below this value, it is considered as being faulty by the SITOP UPS1600 and is not charged. 3.7.8.8 Load / Save Configurations made in the web server can be saved as zip file. Saved configurations can be loaded back to the web server. Procedure for saving the configuration 1. Select the "Hardware configuration" menu. 2. Select submenu "Load/Save". 3. The zip file now displayed can be saved as a file using the "Save target as" function of the shortcut menu (call by pressing the right-hand mouse key). 4. Enter a file name. 5. Click on "OK" to save the configuration as zip file. Procedure for loading the configuration 1. Select the "Hardware configuration" menu. 2. Select submenu "Load/Save". SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 157 Engineering and remote access 3.8 OPC UA server 3. In the editor area, click on "Browse", and in the file dialog, select the path where the configuration file should be saved. 4. Click on the "OK" button to load the configuration. 3.8 OPC UA server 3.8.1 Introduction OPC UA (Open Platform Communications - Unified Architecture) for non-proprietary communication in automation systems. You can find information in the Internet at opcfoundation.org (https://opcfoundation.org/about/opc-technologies/opc-ua/). 3.8.2 Preconditions Note Example of an installation Using "UaExpert" as example, this section describes how, using a client, you access SITOP UPS1600 data. UaExpert V1.4.4 is installed. The OPC UA client for Microsoft Windows can be downloaded from the Internet site of Unified Automation: https://www.unified-automation.com/downloads/opc-ua-clients.html (https://www.unifiedautomation.com/downloads/opc-ua-clients.html) Main module SITOP UPS1600 operates with firmware version v2.2.0 or higher. The IP address of SITOP UPS1600 is configured. The OPC UA server of the SITOP UPS1600 is activated. Note For OPC UA, every device is assigned a profile, which describes the capability of the particular device. The OPC UA server of the SITOP UPS1600 corresponds to the "Micro Embedded Device Server" profile. SITOP UPS1600 / UPS1100 158 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.8 OPC UA server Note Additional information on the OPC UA client is provided in the online documentation in menu "Help > UaExpert Manual". 3.8.3 Activating the OPC UA server via the SITOP UPS1600 web server Start the web server of the SITOP UPS1600 in the MANUAL mode Note The MANUAL mode permits read access operations and restricted write access operations. Preconditions: * The settings of the SITOP UPS1600 correspond to the factory settings ("out-of-the-box"). * The SITOP UPS1600 web server is activated, see "Accessing the web server (Page 135)". * The required IP address is already configured, see "Functions of the web server (Page 139)". Changing the IP address 1. Navigate to "HW configuration > General > Communication interface". 2. Activate "Fixed IP address" 3. Under "Fixed IP address" enter the preferred IP address and the subnet mask. 4. Click on "Download to device". Note New IP address is immediately activated. The connection to the web server is immediately interrupted. 5. Wait at least 2 minutes. 6. In the web browser, call the web server again by entering the new IP address. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 159 Engineering and remote access 3.8 OPC UA server 7. On the web server homepage, select "Login". 8. As login, enter admin - and as password, also admin. Note For security reasons, the default password should be immediately changed. Further, it is recommended that passwords are regularly changed. The password must satisfy the following minimum requirements: * min. 8 characters * min. 1 uppercase letter * min. 1 lowercase letter * min. 1 digit * min. 1 special character The following characters are possible: ^[a-z0-9A-Z\\-_]+$ Activating the OPC-UA server and starting the web server for REMOTE operation 1. Navigate to "HW Configuration > General > OPC UA server > Settings". 2. Activate option "OPC UA server activated". 3. Click on "Download to device". The OPC UA server is activated. 3.8.4 Establishing a connection to the OPC UA server of the SITOP UPS1600 Note The "Ua Expert" program is displayed in English. 1. Launch the "Ua Expert" program. 2. In the main menu, select "Server > Add". 3. In the "Add Server" dialog box, click on "Double click to Add Server ...". SITOP UPS1600 / UPS1100 160 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.8 OPC UA server 4. In dialog "Enter Url", enter the protocol being used, the IP address of the SITOP UPS1600 and the number of ports. The preset port number for OPC UA is 4840. Another port number can be set using the web server, PROFINET or OPC UA. 5. In dialog "Add Server" in area "Authentication Settings", enter the logon information for the SITOP UPS1600. 6. Click on the newly created server link "opc.tcp:\\...". SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 161 Engineering and remote access 3.8 OPC UA server 7. Select the connection type and enter the appropriate login data. For security reasons we recommend using an encrypted connection type (Basic128Rsa15 or Basic256). Default Username: admin Default password: admin 8. Select SITOP UPS1600 in the project tree. 9. Click on symbol "Connect Server". In area "Address Space", the data objects available for the SITOP UPS1600 are shown in a tree structure. SITOP UPS1600 / UPS1100 162 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.8 OPC UA server SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 163 Engineering and remote access 3.8 OPC UA server 3.8.5 Working with the OPC UA client 3.8.5.1 Displaying SITOP UPS1600 parameters Browse nodes - display parameters Input and output data - as well as the operating states of the SITOP UPS1600 - are displayed in area "Address Space" in a tree-like structure as nodes. The properties of a marked node are displayed in area "Attributes". Subscribe to a node The actual values of a subscribed node are permanently displayed in area "Data Access View". To subscribe to a node, drag the appropriate node from area "Address Space" - and drop into area "Data Access View". SITOP UPS1600 / UPS1100 164 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.8 OPC UA server A subscription can only be made to nodes of NodeClass "Variable" 3.8.5.2 . Changing the value of a node Write access operations to values are not permitted in order to avoid making undesirable changes. Write access is made possible by calling method "InitLock". After 10 seconds, access is automatically blocked again. Permitting write access Note Write access only for devices with PROFINET interface Write access via OPC UA is not supported by devices with USB interface (... - 1AY0). SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 165 Engineering and remote access 3.8 OPC UA server 1. In the "Address Space" select . 2. Right click on method "InitLock" and in the shortcut menu, select "Call ...". 3. In the "Call InitLock" dialog box, click on "Call". Figure 3-4 "Call InitLock on Lock" dialog SITOP UPS1600 / UPS1100 166 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.8 OPC UA server 3.8.5.3 Calling a method Calling a method from the "MethodSet" The call is described using example "SynchronizeSystem". Note Methods are shown in the UA client with the symbol . 1. In "Address Space" select . 2. Right click on method "SynchronizeSystem" and in the shortcut menu, select "Call ...". The result of the method call is displayed in a dialog. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 167 Engineering and remote access 3.8 OPC UA server 3.8.6 SITOP UPS1600 parameters in the OPC UA client 3.8.6.1 Introduction The OPC UA client uses the following symbols: Object Object (supported modules) Method Variable with other attributes (EURange, EngineeringUnits, EnumStrings) Variable Information on the selected object is displayed in area "Attributes". Relationships to other objects are displayed in area "References". A dialog is displayed when calling a method. "InputArguments" and "OutputArguments" can be entered here. Values that can be changed (e.g. IP addresses or path data) can be directly edited in area "Attributes". 3.8.6.2 ActualBatteryState Display name Data type Definition Description BatteryChange Recommended Boolean PropertyType Battery capacity is insufficient to achieve the specified buffer time. BatteryCharge Byte AnalogItemType Battery charge level in percent BatteryChargeVoltage Float AnalogItemType Voltage used to charge battery during the constant charging phase. SITOP UPS1600 / UPS1100 168 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.8 OPC UA server Display name Data type Definition Description BatteryConnection Fault Boolean PropertyType The connection to the battery has been interrupted or has a high impedance. BatteryCount Byte PropertyType Number of connected batteries. Only coded batteries are counted. BatteryVoltage Float AnalogItemType Current battery voltage 3.8.6.3 ActualBufferState Display name Data type Definition Description BufferMode Enumeration MultiState DiscreteType Indicates buffer mode BufferReady Boolean PropertyType Sufficient buffer readiness BufferRemainingTime UInt32 AnalogItemType Estimated remaining buffer time. The remaining buffer time is calculated using the current battery charge level and average current over 10 minutes. 3.8.6.4 ActualChargingState Display name Data type Definition ChargeMeasured Current Float AnalogItemType Measured battery charge current ChargeSufficient Boolean PropertyType When this flag is set, the required charge level has been achieved 3.8.6.5 Description ActualState Display name Data type Definition Description DeviceAlarmLed Object Sitop_1600_ LedType Status of LED "Alarm" DeviceBatteryFaultLed Object Sitop_1600_ LedType Status of LED "BatteryFault" DeviceBattery Over85Led Object Sitop_1600_ LedType Status of LED "BatteryOver85" DeviceCalculated Capacity Float AnalogItemType Available battery capacity DeviceCalculated Health Byte AnalogItemType State of health (SoS) as percentage of the rated capacity DeviceInputCurrent Float AnalogItemType Measured input current of SITOP UPS1600 DeviceInputVoltage Float AnalogItemType Input voltage DeviceInputVoltageOK Boolean PropertyType DeviceLoadCurrent AnalogItemType Measured output current of SITOP UPS1600 Float Input voltage has exceeded the configured threshold voltage. Connected devices are powered with the input supply. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 169 Engineering and remote access 3.8 OPC UA server Display name Data type Definition DeviceMaxCurrent Float AnalogItemType Maximum output current supported by the SITOP UPS1600 Description DeviceOutputCurrent Float AnalogItemType Measured output current of SITOP UPS1600 DeviceOutputVoltage Float AnalogItemType Maximum output voltage DeviceP1LinkLed Object Sitop_1600_ LedType Status of LED "P1" DeviceP2LinkLed Object Sitop_1600_ LedType Status of LED "P2" DeviceRunLed Object Sitop_1600_ LedType Status of LED "RUN" DeviceSFLed Object Sitop_1600_ LedType Status of LED "SF" DeviceSWSettings Valid Boolean PropertyType This object provides information about whether the SW parameters or the parameters at the rotary switches are used. The desired setting is selected on rotating switch for threshold voltage. DeviceStateLed Object Sitop_1600_ LedType Status of LED "OK": Device status DeviceTemperature Sbyte AnalogItemType Device temperature DeviceTotalOperating Time UInt32 AnalogItemType Battery-specific data: Total time for which battery was in buffer mode during its service life 3.8.6.6 ActualUpdateState Display name Data type Definition Description UpdateProgress Integer PropertyType Update progress UpdateState Enumeration MultiState DiscreteType Update status Display name Data type Definition Description AlarmBattery ConnectionBroken Boolean PropertyType Connection to battery interrupted - check connection and fuse AlarmBattery ConnectionHigh Resistive Boolean PropertyType High-resistance connection to battery - check battery power cable AlarmBatteryDeep Discharge Boolean PropertyType Battery is deep discharged - no buffering possible AlarmBatteryDeep DischargeNoCharging Possible Boolean PropertyType Battery is deep discharged - replace battery AlarmBatteryDefekt Boolean PropertyType Battery defective - check fuse and battery voltages AlarmBatterySOHTest Boolean PropertyType Battery 'state of health' (SOH) tests are in progress 3.8.6.7 Alarm SITOP UPS1600 / UPS1100 170 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.8 OPC UA server Display name Data type Definition Description AlarmBatteryTest Boolean PropertyType Battery 'state of health' (SOH) tests are in progress. Output of SITOP UPS1600 is connected to the battery to detect the actual capacity of the battery. AlarmBufferMode NotPossible Boolean PropertyType Buffer mode not possible - check settings, cabling, fuse, and battery voltages AlarmBuffer TimerReset Boolean PropertyType PC is shutting down AlarmBuffering Boolean PropertyType Device is in buffer mode AlarmCommunication ToDeviceFailed Boolean PropertyType PROFINET connection available - SITOP UPS1600 is defective AlarmDevice Failure Boolean PropertyType Device failure AlarmDevice Overtemperature Boolean PropertyType Output and battery charging is switched off to prevent damage to the device. AlarmDevice ParameterCorrupt Boolean PropertyType SITOP UPS1600 parameters corrupt - try to update the software AlarmDevice PoweredUp Boolean PropertyType Device powered up AlarmDevice TemperatureHigh Boolean PropertyType Device temperature is very high! Provide cooling or turn off unnecessary consumers. AlarmDevice TemperatureLow Boolean PropertyType Device temperature is very low. Care for higher ambient temperature. AlarmDevice TurnedOff Boolean PropertyType SITOP UPS1600 off - buffer time exceeded or PC was shut down AlarmFirmware UpdateOK Boolean PropertyType Previous software update was successful - SITOP UPS1600 is operational again. AlarmFuseBroken Boolean PropertyType Fuse is defective. AlarmInpu tVoltageHigh Boolean PropertyType Input voltage exceeds 30 V. SITOP UPS1600 is not operational. Alarm InsufficientCharge Boolean PropertyType Set buffer time can currently not be achieved due to low battery charge. AlarmLow VoltageMode Boolean PropertyType Input voltage of SITOP UPS1600 is too low. SITOP UPS1600 Buffer is not ready for buffering. AlarmOutputTurnedOff Boolean PropertyType Output of SITOP UPS1600 has been switched off due to the execution of a command or because an error situation has occurred (e.g. temperature or output current too high). AlarmOutputTurnedOn Boolean PropertyType Output of SITOP UPS1600 has been switched on again due to the execution of a command or because an error situation has been remedied. AlarmOverCurrent Boolean PropertyType Output current of SITOP UPS1600 is too high. Output will be switched off for 20s. The output will be switched on again after 20 s. AlarmResetExecuted Boolean PropertyType Input voltage to SITOP UPS1600 was OK again before the buffer time expired. Connected devices are reset by switching off the SITOP UPS1600 outputs for the configured time. AlarmSurplusBattery Boolean PropertyType More than 6 batteries are connected. Connect only up to 6 batteries at the Energy Storage Link. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 171 Engineering and remote access 3.8 OPC UA server Display name Data type Definition Description AlarmUnknownBattery Boolean PropertyType Data from the battery cannot be read correctly. Battery is defective or not supported by SIEMENS. AlarmWrongBattery Configuration Boolean PropertyType Different battery types connected. Only batteries of the same type can be operated together. AlarmWrongBattery Polarity Boolean PropertyType Wrong battery polarity - check battery connections. Description 3.8.6.8 Battery Display name Data type Definition BatteryCapacity Setpoint Float AnalogItemType Total battery capacity in Ah BatteryDefectVoltage Setpoint Float AnalogItemType If battery voltage is lower than this value, the battery is considered defective BatteryIgnoreCoding Setpoint Boolean PropertyType When this parameter is set to '1', data from the coded battery is ignored. The data is taken from the parameter assignment in this case. Description 3.8.6.9 Buffering Display name Data type Definition BufferExpected CurrentSetpoint Float AnalogItemType Estimated average output current during buffer mode BufferThreshold Setpoint Float PropertyType BufferTime2Setpoint UInt16 AnalogItemType Additional buffer time after PC shutdown (valid only in conjunction with SITOP UPS Manager) BufferTimeSetpoint UInt16 AnalogItemType Desired buffering time before device switches off BufferingEnableSetpoint Boolean PropertyType BufferingEndVoltage Setpoint Float AnalogItemType When battery voltage is lower than this voltage, the battery charge is no longer sufficient. Buffering is stopped. BufferingValid SupplyVoltage TimeSetpoint Float AnalogItemType When the SITOP UPS1600 is in buffer mode, time for which the input voltage must be OK again before SITOP UPS1600 buffering is stopped and connected devices are operated again with input supply. Trigger voltage for buffering - buffering is activated below this value Enable buffering SITOP UPS1600 / UPS1100 172 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.8 OPC UA server 3.8.6.10 Charging Display name Data type Definition ChargingCurrent Setpoint Float AnalogItemType Charge current ChargeEndVoltage Setpoint Float AnalogItemType Battery voltage when charging changes to trickle charging. Battery is charged 100 %. 3.8.6.11 Description General Display name Data type Definition AlarmInvalidSupply VoltageTimeSetpoint Float AnalogItemType Alarm filter: an alarm is only sent if it is pending for longer than the configured time DeviceOutputEnable Setpoint Boolean PropertyType DeviceOutputEnableSetpoint ResetEnableSetpoint Boolean PropertyType When input voltage returns during buffering, the output is switched off for a configurable time in order to reset connected devices ResetTimerSetpoint Byte AnalogItemType Time for which the output of SITOP UPS1600 is switched off when connected devices are reset. ResistorTestInterval Setpoint Byte AnalogItemType Battery test interval 3.8.6.12 Description Hardware Display name Data type Definition Description HardwareBattery ProfileClamp Enumeration MultiState DiscreteType The charge characteristic for batteries on signal terminals is set. This setting is only applied if hardware settings are effective. HardwareBuffer ThresholdSwitch Enumeration MultiState DiscreteType Trigger voltage for buffering - buffering is activated below this value HardwareBuffer TimeSwitch Enumeration MultiState DiscreteType Desired buffering time before device switches off HardwareBuffering EnableClamp Boolean PropertyType Enable buffering HardwareEnable ResetClamp Boolean PropertyType When input voltage returns during buffering, the output is switched off for a configurable time in order to reset connected devices HardwareStartFrom BatteryClamp Boolean PropertyType Setting for 'Start from battery' on signal terminal SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 173 Engineering and remote access 3.8 OPC UA server 3.8.6.13 Identification Display name Data type Definition Description IdentificationContact Setpoint String[64] PropertyType Contact IdentificationDevice NameSetpoint String[32] PropertyType PROFINET device name IdentificationLocation Setpoint String[44] PropertyType Location ID Data type Definition Description BreakLock Method Method ExitLock Method Method InitLock Method Method Locked Boolean PropertyType Locked LockingClient String[16] PropertyType LockingClient LockingUser Unsigned PropertyType LockingUser RemainingLockTime Duration PropertyType RemainingLockingTime RenewLock Method Method 3.8.6.14 Lock Display name 3.8.6.15 MethodSet Display name Data type Definition Description AddUser Method Method Adds a user. ChangeUserPassword Method Method Changes a user password. ClearAlarmHistory Method Method Deletes the alarm history. DeleteUser Method Method Removes a user. DownloadDevice Configuration Method Method Downloads the device configuration. RemoteReset Method Method Executes a remote reset. RemoteReset2 Method Method Executes a remote reset. ResetSystem Method Method Resets the system to the initial state. ResetToFactory Settings Method Method Reset to factory settings. SetNetworkParameter Method Method Sets the network parameters. ShowAlarmHistory Method Method Shows the alarm history. ShowPending AlarmList Method Method Shows the list of active alarms. UpdateFirmware Method Method Updates the firmware. UploadAlarmHistory Method Method Uploads the alarm history. UploadCertificate Method Method Uploads a certificate. SITOP UPS1600 / UPS1100 174 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.8 OPC UA server Display name Data type Definition Description UploadDevice Configuration Method Method Uploads the device configuration. UploadLicence Information Method Method Uploads license information. UploadPendingAlarm List Method Method Uploads the list of active alarms. 3.8.6.16 Network Display name Data type Definition Description NetworkDHCPEnable Boolean PropertyType DHCP enable NetworkGateway String[16] PropertyType Router address NetworkIP String[16] PropertyType IP address NetworkSubnetmask String[16] PropertyType Subnet mask Display name Data type Definition Description NTPEnableSetpoint Boolean PropertyType NTP client activated NTPServer1Setpoint String PropertyType NTP server address 1 NTPServer2Setpoint String PropertyType NTP server address 2 NTPServer3Setpoint String PropertyType NTP server address 3 NTPServer4Setpoint String PropertyType NTP server address 4 NTPUpdateIntervall Setpoint UInt32 AnalogItemType Data type Definition Description NTPLastSynchronisationTime 1) PropertyType Last synchronization instant NTPNextSynchronisationTime 1) PropertyType Next synchronization instant 3.8.6.17 NTP NTP client status Display name 1) read only SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 175 Engineering and remote access 3.8 OPC UA server 3.8.6.18 OPC UA Display name Data type Definition Description OPCUAServerEnable Setpoint Boolean PropertyType OPC UA server activated OPCUAServerPort Setpoint Integer PropertyType OPC UA server port OPCUAUnencrypted AccessEnable Setpoint Boolean PropertyType Unencrypted access activated 3.8.6.19 ParameterSet / All variables of the SITOP UPS1600 are listed together under the "ParameterSet" node. 3.8.6.20 PROFINET Display name Data type Definition Description PNARSetupLocked Setpoint Boolean PropertyType AR configuration locked PNDCPReadonly EnableSetpoint Boolean PropertyType ODCP write protection activated 3.8.6.21 SubDevices In folder "SupportedTypes", variables and methods are listed, which are available for the buffer modules. SITOP UPS1100 ActualBufferState Display name Data type Definition BufferTime UInt32 AnalogItemType Desired buffering time before device switches off Description BufferingEndVoltage Float AnalogItemType When battery voltage is lower than this voltage, the battery charge is no longer sufficient. Buffering is stopped. SITOP UPS1600 / UPS1100 176 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.8 OPC UA server ActualChargingState Display name Data type Definition ChargeCurrent Float AnalogItemType Actual charging current used to charge battery. Description ChargeEndVoltage Float AnalogItemType Battery voltage when charging changes to trickle charging. Battery is charged 100 %. ChargeTotalCurrent Float AnalogItemType Battery-specific data: Total charge to the battery during its service life ActualState Display name Data type Definition ModuleCalculated Capacity Float AnalogItemType Available battery capacity Description ModuleCalculated Health Byte AnalogItemType State of health (SoS) as percentage of the rated capacity ModuleCapacity Float AnalogItemType Capacity ModuleChange Recommended Boolean PropertyType Battery capacity is insufficient to achieve the specified buffer time. ModuleCompound Enumeration MultiState DiscreteType Connected device ModuleConnection Fault Boolean PropertyType Connection to battery interrupted - check connection and fuse ModuleManufactoring Date Date PropertyType Manufacturing date of the battery modules. ModuleMax Temperature Sbyte AnalogItemType Maximum specified operating temperature of the battery. ModuleMin Temperature Sbyte AnalogItemType Minimum specified operating temperature of the battery. ModuleStandbyTime UInt32 AnalogItemType Battery-specific data: Time for which battery was connected but no power was consumed. ModuleStateLed Object Sitop_1600_ LedType ModuleTemperature Sbyte AnalogItemType Battery temperature ModuleTotalCulled Current Float AnalogItemType Battery-specific data: Time for which battery was connected and power was consumed. ModuleStateLed Alarm Display name Data type Definition Description AlarmBatteryChange Canceled Boolean PropertyType Battery replacement canceled - battery parameters are not reset AlarmBatteryChange FInished Boolean PropertyType Battery replacement finished - counters have been reset AlarmBatteryChange Started Boolean PropertyType Battery replacement started by user AlarmBattery CommunicationFault Boolean PropertyType Communication with formerly known battery is no longer possible - check communication SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 177 Engineering and remote access 3.8 OPC UA server Display name Data type Definition Description AlarmBatteryDefect Boolean PropertyType Battery defective - check fuse and battery voltages AlarmBattery ParametersCorrupt Boolean PropertyType Battery defective - replace battery AlarmBattery TemperatureHigh Boolean PropertyType Battery temperature too high - battery life will be shortened AlarmBattery TemperatureLow Boolean PropertyType Battery temperature too low - reduced output current AlarmFuseBroken Boolean PropertyType Fuse is defective. AlarmNewBattery Detected Boolean PropertyType A new battery was connected. The battery will be included in the calculation of the total capacity and the charge parameters. Additional parameters Display name Data type Definition DeviceManual String PropertyType HardwareRevision String PropertyType Manufacturer LocalizedText PropertyType Model LocalizedText PropertyType OrderNumber String[20] PropertyType RevisionCounter Int32 PropertyType SerialNumber String[16] PropertyType SlotId UInt16 PropertyType SoftwareRevision Integer PropertyType MaxModuleCount Byte PropertyType Description Product state Order number/MLFB Serial number Software version/SWD ParameterSet / All variables of the SITOP UPS1100 buffer module are listed together under the "ParameterSet" node. Display name Data type Definition Description AlarmBatteryChange Canceled Boolean PropertyType Battery replacement canceled - battery parameters are not reset AlarmBatteryChange FInished Boolean PropertyType Battery replacement finished - counters have been reset AlarmBatteryChange Started Boolean PropertyType Battery replacement started by user AlarmBattery CommunicationFault Boolean PropertyType Communication with formerly known battery is no longer possible - check communication AlarmBatteryDefect Boolean PropertyType Battery defective - check fuse and battery voltages AlarmBattery ParametersCorrupt Boolean PropertyType Battery defective - replace battery AlarmBattery TemperatureHigh Boolean PropertyType Battery temperature too high - battery life will be shortened SITOP UPS1600 / UPS1100 178 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.8 OPC UA server Display name Data type Definition Description AlarmBattery TemperatureLow Boolean PropertyType Battery temperature too low - reduced output current AlarmFuseBroken Boolean PropertyType Fuse is defective. AlarmNewBattery Detected Boolean PropertyType A new battery was connected. The battery will be included in the calculation of the total capacity and the charge parameters. BufferTime UInt32 AnalogItemType Desired buffering time before device switches off BufferingEndVoltage Float AnalogItemType When battery voltage is lower than this voltage, the battery charge is no longer sufficient. Buffering is stopped. ChargeCurrent Float AnalogItemType Actual charging current used to charge battery. ChargeEndVoltage Float AnalogItemType Battery voltage when charging changes to trickle charging. Battery is charged 100%. ChargeTotalCurrent Float AnalogItemType Battery-specific data: Total charge to the battery during its service life ModuleCalculated Capacity Float AnalogItemType Available battery capacity ModuleCalculated Health Byte AnalogItemType State of health (SoS) as percentage of the rated capacity ModuleCapacity Float AnalogItemType Capacity ModuleChange Recommended Boolean PropertyType Battery capacity is insufficient to achieve the specified buffer time. ModuleCompound Enumeration MultiState DiscreteType Connected device ModuleConnection Fault Boolean PropertyType Connection to battery interrupted - check connection and fuse ModuleMax Temperature Sbyte AnalogItemType Maximum specified operating temperature of the battery. ModuleMin Temperature Sbyte AnalogItemType Minimum specified operating temperature of the battery. ModuleStandbyTime UInt32 AnalogItemType Battery-specific data: Time for which battery was connected but no power was consumed. ModuleStateLed Object Sitop_1600_ LedType ModuleTemperature Sbyte AnalogItemType Battery temperature ModuleTotal CulledCurrent Float AnalogItemType Battery-specific data: Time for which battery was connected and power was consumed. 3.8.6.22 ModuleStateLed UserManagement Display name Data type Definition Description AddUser Method Method Adds a user. ChangeUserPassword Method Method Changes the password for the user. DeleteUser Method Method Deletes the user. UsermanagementUser SitopUserType 1 ... 16 SitopUserType SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 179 Engineering and remote access 3.8 OPC UA server Display name Data type Definition Description AccessLevel1Setpoint Boolean PropertyType Can read data AccessLevel2Setpoint Boolean PropertyType Can read device configuration AccessLevel3Setpoint Boolean PropertyType Can write device configuration to device AccessLevel4Setpoint Boolean PropertyType Can read device settings AccessLevel5Setpoint Boolean PropertyType Can write device configuration to device AccessLevel6Setpoint Boolean PropertyType Can read alarm list AccessLevel7Setpoint Boolean PropertyType Can delete and save alarm list AccessLevel8Setpoint Boolean PropertyType Can change operating mode AccessLevel9Setpoint Boolean PropertyType Can perform firmware update AccessLevel10S etpoint Boolean PropertyType Can call special functions AccessLevel11 Setpoint Boolean PropertyType Can administer users UserName String[16] PropertyType User name [1 ... 16] 3.8.6.23 Web server Display name Data type Definition Description WebserverAutoLogout EnableSetpoint Boolean PropertyType Log off automatically after 15 minutes WebserverAutoReload Boolean EnableSetpoint PropertyType Activate automatic update. WebserverEnable Setpoint Boolean PropertyType Activate web server on this module. Webserver HttpAccessEnable Setpoint Boolean PropertyType Permit access only with HTTPS WebserverReload TimeSetpoint Enumeration MultiState DiscreteType Update interval: 3.8.6.24 Additional These nodes are listed at the first level in the object tree Display name Data type Definition Description DeviceManual String PropertyType Address (path in the file system or URL / web address) of the operating instructions for the device. Hardware Revision String PropertyType Revision status of the device hardware. Manufacturer LocalizedText PropertyType Name of the company that manufactured the device Model LocalizedText PropertyType ModuleItemNumber UInt32 PropertyType OrderNumber String[20] PropertyType RevisionCounter Int32 PropertyType Incremental counter that specifies how often the static data in the device was modified. SITOP UPS1600 / UPS1100 180 Manual, 04.2017, A5E37775406-8-76 Engineering and remote access 3.8 OPC UA server Display name Data type Definition Description SerialNumber String PropertyType ID, which uniquely identifies the device for the device manufacturer SoftwareRevision String PropertyType Revision status of the device software. 3.8.7 OPC UA performance OPC UA provides the option of collectively transferring modified actual values in the form of a subscription. The minimum pole interval of such a subscription is 100 ms. A maximum of 150 data nodes can be simultaneously monitored, independent of whether these data nodes are assigned one or various subscriptions. OPC UA does not support any type of realtime communication, neither for actual values (read data) nor for setpoints (written data). As a consequence, it is not possible to specify an update/refresh rate or a maximum data flow rate. 3.8.8 Recommissioning after a basic device has been replaced - or after restoring the factory settings If, for service reasons it is necessary to replace the basic device - or store the factory settings, then please observe the following notes: 1. Brand new basic devices or basic devices, where the factory settings have been restored, have no IP address. However, this is generally necessary so that the device can be accessed using OPC UA. Proceed as described in Chapter General (Page 146), Section "communication interface" to assign the device a certain IP address. 2. The configuration must be loaded to the device. This can be done in the following ways: Proceed as described in Chapter Load / Save (Page 157) to load a valid configuration into the device (previously saved via web server). Load a valid configuration to the device via OPC UA. Ensure that the necessary user account is available in the device for access via OPC UA. The latter can be created using a web server, see Chapter Web server (Page 148). SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 181 Engineering and remote access 3.8 OPC UA server SITOP UPS1600 / UPS1100 182 Manual, 04.2017, A5E37775406-8-76 4 Troubleshooting You can obtain additional information on an active alarm from the help text. The extended error type is used to interpret alarms in S7 function blocks that you have programmed yourself. The severity indicates the severity of the alarm: D = diagnostics MD = Maintenance Demanded MR = Maintenance Required F = Failure (module has failed) Error Type Extended Error Type Severity Alarm Text Help Text 256 1 F Software corrupted Software is corrupt - try to update the software 256 2 256 3 MR Wrong checksum Internal error: Communication disrupted MR Parameter corrupt Attempting to write to an unknown or read-only object. 256 4 MR Unknown parameter Attempting to set a parameter that is not known by UPS1600. 256 5 MR Wrong message length Internal error: Communication disrupted 256 6 MR Wrong parameter Parameter value is not within the specified range 256 7 MR Command not accepted An incorrect command was sent to the UPS1600 256 8 MR Communication error: Wrong length field Syntax error in command 256 9 MR Wrong request Error in sent message: Unknown request sent. 256 10 MR Cannot write to object Attempting to write a parameter that is "read-only" 256 11 MR Object pending UPS1600 cannot provide data for the requested object. 256 12 MR Battery not available Attempting to access a battery that is not available. Either the battery with the requested number was never connected or communication with this battery was interrupted. 256 13 MR EEPROM write error Saving UPS1600 parameters failed. Device is defective. 256 14 MR Unknown alarm Internal error: Wrong parameter at execution of test command. 256 15 MR Command outside range An incorrect command was sent to the UPS1600 256 16 MR Software update is being performed The command sent cannot be executed as long as the program is running. 256 17 MR No software update Cannot execute the sent command because no software update has been started. 256 18 MR Wrong battery number Attempting to retrieve data about a battery which does not exist or is not connected. 256 19 MR Wrong address Wrong Flash address in software update - software update file is corrupt. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 183 Troubleshooting Error Type Extended Error Type Severity Alarm Text Help Text 256 20 MR Write error Cannot write to Flash - hardware may be defective 256 21 MR Read error Unable to read EEPROM. Device is defective. 256 22 MR Wrong device ID An attempt was made to update the software with an update file that is not suitable for the UPS1600. 256 23 MR Corrupt data record Error during software update - try to update the software again 256 24 MR Wrong update An attempt was made to update the software with an invalid update file. The update file is probably too old. 256 25 MR Too much data An entry in the software update cannot contain more than 32 bytes of reference data. 256 26 F Device failure Device failure 256 27 F No boot loader available No boot loader available 257 1 MD Buffer mode is not possible Buffer mode is not possible - check settings, cabling, fuse, and battery voltages 257 2 MD Device temperature critical (too high) Device temperature is very high! Ensure adequate cooling or disconnect unnecessary loads. 257 3 MD Device temperature critical (too low) Device temperature is very low! Ensure a higher ambient temperature. 257 4 F High-resistance connection to battery High-resistance connection to battery - check battery power cable 257 5 F Connection to battery interrupted Connection to battery interrupted - check connection and fuse 257 6 MD Unknown battery Data from the battery cannot be read correctly. Battery is defective or not supported by SIEMENS. 257 7 MR Overcurrent Output current of UPS1600 is too high. Output will be switched off for 20s. The output will be switched on again after 20s. 257 8 MR Reset buffer timer PC is shutting down 257 9 MR UPS1600 off UPS1600 off - buffer time exceeded or PC was shut down 257 10 MR Output switched off The UPS1600 output was shut down as result of executing an instruction or an error situation (e.g. overtemperature, excessive output current). 257 11 MR Output switched on The UPS1600 output was switched on again as result of executing an instruction or the correction of an error situation. 257 12 MR Reset executed Input voltage at UPS1600 was OK again before the buffer time expired. Connected devices are reset by switching off the UPS1600 outputs for the configured time. 257 13 MR Battery test A cyclic battery test will be performed Remark: For firmware versions from V2.2 - and for versions V2.0.x from version V2.0.5, the alarm is deactivated. 257 14 MR Software update successful Previous software update was successful - UPS1600 is operational again. 257 15 MR Input voltage is too high Input voltage exceeds 30 V. UPS1600 is not operational. 257 16 MD Surplus battery More than 6 batteries are connected. Connect a maximum of 6 batteries to the Energy Storage Link. SITOP UPS1600 / UPS1100 184 Manual, 04.2017, A5E37775406-8-76 Troubleshooting 4.1 Hardware fault Error Type Extended Error Type Severity Alarm Text Help Text 257 17 F UPS1600 parameters corrupt UPS1600-parameters corrupt - try to update the software. 257 18 F Device overtemperature Output and battery charging is switched off to prevent damage to the device. 257 20 MR Low voltage mode Input voltage of UPS1600 is too low. UPS1600 is not ready for buffering. 257 21 MR Buffering Device is in the buffer mode. 257 22 MR Communication with device failed PROFINET connection available - UPS1600 is defective 257 23 MR Device powered up Device powered up 257 24 F Wrong battery polarity Wrong battery polarity - check battery connections. 257 26 MR Insufficient charge level Set buffer time can currently not be achieved due to low battery charge. 257 27 MR Deep discharge battery Battery is deep discharged - no buffering possible 258 1 F Battery defective (battery index: {1:d}) Battery defective - check the fuse and the battery voltages 258 2 F Deep discharge battery, no charging possible (battery index: {1:d}). Battery is deep discharged - replace battery 258 3 MD Battery temperature high (battery index: {1:d}) Battery temperature too high - battery life will be shortened 258 4 MD Battery temperature low (battery index: {1:d}). Battery temperature too low - reduced output current 258 5 F Communication with battery fault (battery index: {1:d}) Communication with formerly known battery is no longer possible - check communication 258 6 MR New battery detected (battery index: {1:d}) A new battery was connected. The battery will be included in the calculation of the total capacity and the charge parameters. 258 7 F Wrong battery configuration (battery index: {1:d}) Different battery types connected. Only batteries of the same type can be operated together. 258 8 MD Battery parameters corrupt (battery index: {1:d}). Battery defective - replace battery Remark: Alarm is deactivated. 258 9 MR Battery replacement started (battery index: {1:d}) Battery replacement started by user 258 10 MR Battery replacement finished (battery index: {1:d}) Battery replacement finished - counters have been reset 258 11 MD Battery replacement canceled (battery index: {1:d}) Battery replacement canceled - battery parameters are not reset 258 12 F Fuse is defective (battery index: {1:d}) Fuse is defective. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 185 Troubleshooting 4.1 Hardware fault 4.1 Hardware fault For an internally identified software or hardware fault/error, the following response occurs: * LED 1 (O.K./BAT.) lights up red * LED 2/3/4 are dark * Alarm 13 (Device failure) is sent * UPS1600 output shuts down Response from V2.0.4 or V2.1 and higher: The output is only shut down for a software error (internal software error, software update not completed, software checksum is incorrect). SITOP UPS1600 / UPS1100 186 Manual, 04.2017, A5E37775406-8-76 Mounting/removing 5.1 5 SITOP UPS1600 WARNING Installing the device in a housing or a control cabinet The SITOP UPS1600s are built-in units. They must be installed in a housing or control cabinet where only qualified personnel have access. The device can be mounted in a control cabinet on standard TH35x7.5/15 mounting rails (according to EN 60715). WARNING Use in hazardous zones If the device is to be used in a hazardous zone (II 3G Ex nA nC IIC T4 Gc) it must be installed in a distribution box with degree of protection IP54 or higher. This distribution box must comply with the requirements of EN 60079-15. Mounting To mount the device, position it with the mounting rail guide at the upper edge of the standard mounting rail and press down to lock it into place. If this is too difficult, press slider at the same time, as described under "Removal". Removal To remove, carefully open the slider using a screwdriver or by hand (see Figure 5-1 Removal (example 6EP4136-3AB00-2AY0) (Page 188)) and disengage the device at the bottom edge of the standard mounting rail. Then you can remove the device from the upper edge of the standard mounting rail. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 187 Mounting/removing 5.1 SITOP UPS1600 Figure 5-1 5.1.1 Removal (example 6EP4136-3AB00-2AY0) Signal connector Mounting Push connector on socket in the housing. Removal To remove the signal connector, press the release lever (4b) (see Figure 5-2 Mounting/removal: Signal connector (Page 188)) and then remove the connector. Figure 5-2 Mounting/removal: Signal connector SITOP UPS1600 / UPS1100 188 Manual, 04.2017, A5E37775406-8-76 Mounting/removing 5.1 SITOP UPS1600 5.1.2 USB connector For deployment in an explosion-endangered environment, a USB connector with strain relief must be used. Mounting Push the connector onto the socket in the housing until the strain relief (6b) snaps into the housing (6a). Removal To remove the USB connector, press to release the strain relief (6b) (see Figure 5-3 Mounting/removal: USB connector (Page 189)) and then remove the connector. Figure 5-3 Mounting/removal: USB connector SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 189 Mounting/removing 5.1 SITOP UPS1600 5.1.3 PROFINET/Ethernet connector For use in a hazardous zone, a PROFINET/Ethernet connector with strain relief must be used. Mounting Push the connector onto the socket in the housing until the strain relief (5b) snaps into the housing (5a). Removal To remove the PROFINET/Ethernet connector, press to release the strain relief (5b) (see Figure 5-4 Mounting/removal: Ethernet (Page 190)) and then remove the connector. Figure 5-4 Mounting/removal: Ethernet SITOP UPS1600 / UPS1100 190 Manual, 04.2017, A5E37775406-8-76 Mounting/removing 5.2 SITOP UPS1100 5.2 SITOP UPS1100 WARNING Mounting the device in a housing or a control cabinet The SITOP UPS1100 battery modules are built-in units. They must be mounted in a housing or control cabinet where only qualified personnel have access. All devices are suitable for direct wall mounting. Devices 6EP4131-0GB00-0AY0 (1.2 Ah), 6EP4132-0GB00-0AY0 (2.5 Ah), 6EP41330GB00-0AY0 (3.2 Ah) and 6EP4133-0JB00-0AY0 (5 Ah) can also be snapped onto a standard mounting rail TH35x15 (EN 60715), and device 6EP4131-0GB00-0AY0 (1.2 Ah) also onto a standard mounting rail TH35x7.5 (EN 60715). The lower part of the control cabinet or the coolest location in the control cabinet should be chosen as mounting location. WARNING Use in hazardous zones When the device is installed in a hazardous zone (II 3G nA IIC T4 Gc), not permissible for 6EP4133-0JB00-0AY0 (5 Ah), then this must be installed in a distribution box with degree of protection IP54 or higher. This distribution box must comply with the requirements of EN 60079-15. Mounting See Chapter Dimensions and weight for the holes for wall mounting SITOP UPS1100 (Page 42). To mount the device on a standard mounting rail, place it with the standard mounting rail guide at the upper edge of the standard mounting rail and snap it in downwards. If this is too difficult, push the device downwards while pressing on the rail as described for "Removal". Note The fuses should be inserted in the fuse holder only when commissioning the device (charged batteries). Note The lead acid batteries are fully charged when the device is delivered. The LiFePo battery (5 Ah) is only charged up to a maximum of 30 % of the nominal charge (to comply with transport regulations). Removal To remove the device, pull it forcibly downwards while removing it from the lower edge of the standard mounting rail (see Figure 5-5 Removal (example 6EP4133-0GB00-0AY0 (3,2 Ah)) SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 191 Mounting/removing 5.2 SITOP UPS1100 (Page 192)). Then you can remove the device from the upper edge of the standard mounting rail. Figure 5-5 Removal (example 6EP4133-0GB00-0AY0 (3,2 Ah)) SITOP UPS1600 / UPS1100 192 Manual, 04.2017, A5E37775406-8-76 Mounting position, mounting clearances 6.1 SITOP UPS1600 6.1.1 Standard mounting position 6 The device is mounted on standard mounting rails EN 60715 35x7.5/15. The device must be mounted vertically in such a way that the input terminals and the output terminals are at the bottom to ensure correct cooling. A clearance of at least 50 mm should be maintained above and below the device. No clearance is required at the side. Output current as a function of the ambient temperature Figure 6-1 6EP4134-3AB00-... Output current in the standard mounting position Figure 6-2 6EP4136-3AB00-... Output current in the standard mounting position SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 193 Mounting position, mounting clearances 6.1 SITOP UPS1600 Figure 6-3 6EP4137-3AB00-... Output current in the standard mounting position SITOP UPS1600 / UPS1100 194 Manual, 04.2017, A5E37775406-8-76 Mounting position, mounting clearances 6.1 SITOP UPS1600 6.1.2 Other mounting positions For mounting positions that deviate from the standard mounting position, derating factors (reduction of the output power or the permissible ambient temperature) must be observed in accordance with the following diagrams. Note In the case of mounting positions that deviate from the standard mounting position, reduced mechanical resistance of the devices against vibration and shock must be expected. Particularly when installing on a vertically fastened standard mounting rail, additional measures may be required, e.g. to prevent the device from slipping on the standard mounting rail. 6.1.2.1 6EP4134-3AB00-... Figure 6-4 6EP4134-3AB00-... Mounting position 1 Figure 6-5 6EP4134-3AB00-... Mounting position 2 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 195 Mounting position, mounting clearances 6.1 SITOP UPS1600 Figure 6-6 6EP4134-3AB00-... Mounting position 3 Figure 6-7 6EP4134-3AB00-... Mounting position 4 Figure 6-8 6EP4134-3AB00-... Mounting position 5 SITOP UPS1600 / UPS1100 196 Manual, 04.2017, A5E37775406-8-76 Mounting position, mounting clearances 6.1 SITOP UPS1600 6.1.2.2 6EP4136-3AB00-... Figure 6-9 6EP4136-3AB00-... Mounting position 1 Figure 6-10 6EP4136-3AB00-... Mounting position 2 Figure 6-11 6EP4136-3AB00-... Mounting position 3 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 197 Mounting position, mounting clearances 6.1 SITOP UPS1600 Figure 6-12 6EP4136-3AB00-... Mounting position 4 Figure 6-13 6EP4136-3AB00-... Mounting position 5 SITOP UPS1600 / UPS1100 198 Manual, 04.2017, A5E37775406-8-76 Mounting position, mounting clearances 6.1 SITOP UPS1600 6.1.2.3 6EP4137-3AB00-... Figure 6-14 6EP4137-3AB00-... Mounting position 1 Figure 6-15 6EP4137-3AB00-... Mounting position 2 Figure 6-16 6EP4137-3AB00-... Mounting position 3 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 199 Mounting position, mounting clearances 6.1 SITOP UPS1600 Figure 6-17 6EP4137-3AB00-... Mounting position 4 Figure 6-18 6EP4137-3AB00-... Mounting position 5 SITOP UPS1600 / UPS1100 200 Manual, 04.2017, A5E37775406-8-76 Mounting position, mounting clearances 6.2 SITOP UPS1100 6.2 SITOP UPS1100 6.2.1 Standard mounting position The device is suitable for the direct wall mounting. Devices 6EP4131-0GB00-0AY0 (1.2 Ah), 6EP4132-0GB00-0AY0 (2.5 Ah), 6EP4133-0GB00-0AY0 (3.2 Ah) and 6EP4133-0JB000AY0 (5 Ah) can also be snapped onto a standard mounting rail TH35x15 (EN 60715), and device 6EP4131-0GB00-0AY0 (1.2 Ah), also onto a standard mounting rail TH35x7.5 (EN 60715). It should also be mounted at the coolest point in the control cabinet (e.g. in the lower part of the control cabinet). The device must be mounted vertically in such a way that the terminals are at the bottom. No clearance is required at the side. 6.2.2 Other mounting positions Note In the case of mounting positions that deviate from the standard mounting position, reduced mechanical resistance of the devices against vibration and shock must be expected. Particularly when installing on a vertically fastened standard mounting rail, additional measures may be required, e.g. to prevent the device from slipping on the rail. All mounting positions have been released, except the following: For UPS1100 1.2 Ah: Mounting position (2) (see the following diagram) all other UPS1100: Mounting position (5) (see the following diagram) Figure 6-19 Mounting positions forbidden for the UPS1100 SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 201 Mounting position, mounting clearances 6.3 Altitude derating 6.3 Altitude derating Output current as a function of the altitude derating Figure 6-20 Altitude derating Details see chapter Environmental conditions (Page 225) Note Only applies to the UPS1600. For UPS1100 (with the exception of UPS1100 2.5 Ah) operation at altitudes of 4000 m above sea level is not permissible. SITOP UPS1600 / UPS1100 202 Manual, 04.2017, A5E37775406-8-76 Installation 7 Note When installing the devices, the relevant country-specific regulations must be complied with. The 24 V supply voltage must be SELV in accordance with EN60950-1 and EN50178. Only qualified personnel are allowed to install the device/system and set it into operation. It is not permissible that the connections are attached or detached in operation. Note for SITOP UPS1100 It is recommended that the batteries are only stored fully charged. The lead acid batteries are fully charged when the device is delivered. The LiFePo battery (5 Ah) is only supplied charged up to a maximum of 30 % of the nominal charge (to comply with transport regulations). The self-discharge rate of the batteries is approx. 3%/month for a temperature of 20 C. This value is temperature dependent and becomes more unfavorable for an increasing temperature, and more favorable for a decreasing temperature. The fuses should only be inserted in the fuse holder when commissioning the device. When storing UPS1100 battery modules and completely cabled/wired systems (with UPS1600 and fuse inserted in the UPS1100), it should be taken into account that an additional discharge current of 300 A flows. SITOP UPS1100 1.2 Ah is only recommended in conjunction with SITOP UPS1600 10 A. SITOP UPS1100 2.5 Ah, 3.2 Ah and 5 Ah are only recommended in conjunction with SITOP UPS1600 10 A and 20 A. When using battery modules without Energy Storage Link, it must be ensured that the selected batteries match the data of the UPS1600 (static and dynamic load current, charge current). SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 203 Installation Figure 7-1 Wiring SITOP UPS1600 / UPS1100 204 Manual, 04.2017, A5E37775406-8-76 Installation 7.1 Connecting the SITOP UPS1600 at its input 7.1 Connecting the SITOP UPS1600 at its input SITOP UPS1600 is designed to be connected to a 24 V DC supply. The 24 V supply voltage must be SELV in accordance with EN60950-1 and EN50178. Figure 7-2 Input side connection The 24 V power supply is connected at the "IN+", and "IN-" terminals (see Figure Input side connection (Page 205)). Cables must be used that are suitable for at least 90 C (only for applications for UL508). 7.2 Connecting the SITOP UPS1600 at its output The output of the SITOP UPS1600 is no-load, overload and short-circuit proof. If an overload occurs, the electronic current limiting function limits the output current to a maximum value (see Section Technical data (Page 211)). Figure 7-3 Output-side connection The output voltage is connected at the "OUT+" and "OUT-" terminals (see Figure Outputside connection (Page 205)). Ensure that the output cables are dimensioned correctly for the maximum output current rms value and fused accordingly. The deployed cables must be suitable for temperatures of at least 90 C. (only for applications for UL508) SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 205 Installation 7.3 Connecting the BAT SITOP UPS1600 7.3 Connecting the BAT SITOP UPS1600 Figure 7-4 BAT connection The "BAT+" and "BAT-" connections (see Figure BAT connection (Page 206)) are used to connect the SITOP UPS1600 with one or more SITOP UPS1100 battery modules. Ensure that the cables are dimensioned correctly for the maximum output current rms value of the SITOP UPS1600. For wiring, see Figure Wiring (Page 204). Cables must be used that are suitable for at least 90 C (only for applications for UL508). Maximum cable length 3 m 7.4 USB interface Maximum USB cable length 5 m 7.5 PROFINET/Ethernet connection Maximum length of the PROFINET/Ethernet cable 100 m (90 m BASIC- Link plus 2 x 5 m CHANNEL- Link) SITOP UPS1600 / UPS1100 206 Manual, 04.2017, A5E37775406-8-76 Installation 7.6 SITOP UPS1100 connections 7.6 SITOP UPS1100 connections Connections 1.2 Ah/2.5 Ah/3.2 Ah/5 Ah Connections 7/12 Ah Connection X1 The connections "X1+" and "X1-" are used to transfer power between the SITOP UPS1600 and the SITOP UPS1100. 1. Ensure that the cables are dimensioned corresponding to the fuses in the SITOP UPS1100 and the impedances between SITOP UPS1600 and SITOP UPS1100 are the same. 2. Only connect charged batteries with one another. Connection X2 Connections "X2-1" and "X2-2" serve to transfer data between SITOP UPS1600 and SITOP UPS1100 (see Figure Wiring (Page 204)). When several battery modules are used, note the following: Up to 6 battery modules of the same type can be connected together in parallel. If different battery modules are connected in parallel, the relay REL2 is energized and deenergized at regular intervals (battery defective). No calculations with regard to charge and remaining buffer time are performed. The battery modules are not charged, but buffering is possible. If more than 6 battery modules are connected in parallel, the relay REL2 is energized and de-energized at regular intervals (battery defective). No calculations with regard to charge and remaining buffer time are performed. Charging and buffering, however, is possible. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 207 Installation 7.7 Maintenance 7.7 Maintenance 7.7.1 Battery SITOP UPS1100 devices contain 2 maintenance-free batteries. Device type Battery type 6EP4131-0GB00-0AY0 (1.2 Ah) YUASA NP1,2-12 6EP4132-0GB00-0AY0 (2.5 Ah) Hawker Energy CYCLON 0810-0075 2.5-12 6EP4133-0GB00-0AY0 (3.2 Ah) YUASA NP3,2-12 or B.B.Battery BP3,6-12 6EP4133-0JB00-0AY0 (5 Ah) NEC ALM12V7s 6EP4134-0GB00-0AY0 (7 Ah) YUASA NP7-12 or B.B.Battery BP7-12 6EP4135-0GB00-0AY0 (12 Ah) YUASA NP12-12 or B.B.Battery BP12-12 When replacing the batteries, always use batteries with the same batch number (approximately the same charge state). The rechargeable batteries must be disposed of, discharged according to the applicable regulations. When storing, installing and operating the buffer batteries, the regulations of VDE 0510 Part 2 / EN 50272-2 or the applicable national regulations must be observed. The self-discharge rate of the batteries is approx. 3%/month for a temperature of 20 C. This value is temperature dependent and becomes more unfavorable for an increasing temperature, and more favorable for a decreasing temperature. 7.7.2 Battery replacement See Figure 7-5 Maintenance (Page 209) and Figure 7-6 Wiring schematic (Page 209) 1. Remove the screws using a Torx T10 screwdriver. 2. Open the cover. 3. Press button for at least 2 s. LED flashes 4. Remove fuse 5. Replace the batteries. 6. Press the button for at least 2 s LED stops flashing and lights continuously. 7. Insert the fuse. 8. Close the cover (screw). SITOP UPS1600 / UPS1100 208 Manual, 04.2017, A5E37775406-8-76 Installation 7.7 Maintenance Pressing the button resets the following functions: Operating hours counter Buffer time counter Summed charge current Summed load current Calculated capacity Note Replace the battery only in normal operation, not in backup operation. Figure 7-5 Maintenance Figure 7-6 Wiring schematic SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 209 Installation 7.7 Maintenance SITOP UPS1600 / UPS1100 210 Manual, 04.2017, A5E37775406-8-76 8 Technical data Note Technical data apply for a rated input voltage, rated load and 25 C ambient temperature if nothing else is specified. 8.1 Input data 8.1.1 SITOP UPS1600 6EP4134-3AB00- ... (10 A) Input voltage Uin rated/range 6EP4136-3AB00- ... (20 A) 6EP4137-3AB00- ... (40 A) 24 V DC/21 - 29 V Connection threshold for 22.5 V DC 3 % (factory setting), buffering setting range: 21 V DC, 21.5 V DC, 22 V DC, 22.5 V DC, 23 V DC, 24 V DC, 25 V DC or via software. * Remark The connection (switch-in) threshold must be at least 0.5 V lower than the input voltage (measured at the input terminal under load). After reaching the minimum input voltage at the DC UPS module, the module cannot buffer for a maximum of 1.5 seconds. Input current Iin rated Approx. 14 A at the maximum charge current (3 A) Reverse polarity protection Yes Approx. 25 A at the maximum charge current (4 A) Approx. 46 A at the maximum charge current (5 A) SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 211 Technical data 8.1 Input data 8.1.2 SITOP UPS1100 Charge current The charge current is limited by the maximum permissible charge current of the UPS1600 (see Chapter SITOP UPS1600 (Page 213)) When a battery module is connected, the charge current is max. 0.3C A. For several battery modules connected in parallel, the max. charge current is 0.3C A multiplied by the number of batteries connected in parallel. Recommended end-of-charge voltage (standby use), dependent on the battery temperature 6EP4131-0GB00- ... (1.2 Ah) 6EP4133-0GB00- ... (3.2 Ah) 6EP4134-0GB00- ... (7 Ah) 6EP4135-0GB00- ... (12 Ah) 6EP4132-0GB00- ... (2.5 Ah) 6EP4133-0JB00- ... (5 Ah) At -10 C - 29.0 V 29.28 V At 0 C - 28.6 V 29.52 V At 10 C 27.8 V 28.3 V 29.16 V At 20 C 27.3 V 27.9 V 28.8 V At 30 C 26.8 V 27.5 V 28.8 V At 40 C 26.6 V 27.2 V 28.8 V At 50 C - 26.8 V 27.8 V At 60 C - 26.4 V - Note Battery module UPS1100 5 Ah with LiFePo batteries can only be used in conjunction with UPS1600 from software version V2.1 and higher. See also SITOP UPS1600 (Page 213) Output data (Page 213) SITOP UPS1600 / UPS1100 212 Manual, 04.2017, A5E37775406-8-76 Technical data 8.2 Output data 8.2 Output data 8.2.1 SITOP UPS1600 6EP4134-3AB00- ... (10 A) Output voltage for normal operation Output voltage for buffer mode 6EP4136-3AB00- ... (20 A) 6EP4137-3AB00- ... (40 A) Input voltage Uin approx. - 0.2 V 27 V DC (no-load); 24 V (50 % rated battery current); 22 V (100 % rated battery current); 18.5 V (deep discharge protection) Power-up characteristics Start delay < 1 s Typical voltage increase: < 60 ms Output +BAT/-BAT for normal operation I-U charging characteristic (initially fast charge current, then charge retention). * Remark For one connected battery module the max. charge current is 0.3C A, for several battery modules connected in parallel, the charge current is 0.3C A multiplied by the number of batteries connected in parallel, however, limited by the maximum permissible charge current of the UPS1600. End-of-charge voltage Automatic temperature-controlled setting with the SITOP UPS1100 battery modules Output current - rated value 10 A 20 A 40 A Power boost for 30 ms 30 A 60 A 120 A Extra power for 5 s/min 15 A 30 A 60 A * Remark Charge current * Remark When using the UPS1100 5 Ah, Extra Power is permissible for 1 s/min. Max. 3 A Automatic setting for UPS1100; otherwise 0.3 A, 0.8 A or 3 A can be selected (by software or jumper (see Table 2-5 Charge current (Page 29))) Max. 4 A Automatic setting for UPS1100; otherwise 0.8 A, 1.75 A, 4 A can be selected (by software or jumper (see Table 2-5 Charge current (Page 29))) Max. 5 A Automatic setting for UPS1100; otherwise 0.8 A, 1.75 A, 4 A can be selected (by software or jumper (see Table 2-5 Charge current (Page 29))) The charge current can be automatically reduced if the charge current plus the load current at the UPS1600 results in an overload of the feeding power supply. The charge current can also be reduced if the ambient temperature of the UPS1600 is higher than 40 C - or if the input voltage at the UPS1600 is less than 24 V. Derating: 10 A: 3 A2 A 20 A: 4 A3 A 40 A: 5 A3 A SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 213 Technical data 8.2 Output data 8.2.2 SITOP UPS1100 6EP41310GB00-... (1.2 Ah) 6EP41320GB00-... (2.5 Ah) 6EP41330GB00-... (3.2 Ah) 6EP41330JB00-... (5 Ah) 6EP41340GB00-... (7 Ah) 6EP41350GB00-... (12 Ah) Output voltage rated value 24 V DC Rated voltage range 22 - 27 V DC 22 - 27 V DC 22 - 27 V DC 22 - 28.8 V DC 22 - 27 V DC 22 - 27 V DC Output current rated value 10 A 20 A 20 A 20 A 40 A 40 A Power boost for 30 ms 30 A 60 A 60 A 60 A 120 A 120 A Extra Power for 5 s/min 15 A 30 A 30 A - 60 A 60 A Extra Power for 1 s/min - - - 30 A - - Battery fuse (pluggable) 15 A / 32 V 25 A / 32 V 25 A / 32 V 25 A/32 V 2 x 25 A/32 V 2 x 25 A/32 V Remark: The lead acid batteries are fully charged when the device is delivered. The LiFePo battery (5 Ah) is only supplied charged up to a maximum of 30 % of the nominal charge (to comply with transport regulations). SITOP UPS1600 / UPS1100 214 Manual, 04.2017, A5E37775406-8-76 Technical data 8.3 Backup times 8.3 Backup times Output current 6EP41310GB00- 6EP41320GB00- 6EP41330GB00- 6EP41330JB00- 6EP41340GB00- 6EP41350GB00- ... (1.2 Ah) ... (2.5 Ah) ... (3.2 Ah) ... (5 Ah) ... (7 Ah) ... (12 Ah) 1A 34 minutes 1.7 h 2.5 h 5.2 h 5.4 h 10.3 h 2A 11 minutes 54.6 minutes 1h 2.5 h 2.6 h 4.8 h 3A 9 minutes 32.9 minutes 39 minutes 1.7 h 1.6 h 3h 4A 6 min 20.6 minutes 27 minutes 1.25 h 1.2 h 2.3 h 6A 3.5 minutes 14.3 minutes 17.5 minutes 50.6 minutes 41 minutes 1.4 h 8A 2 minutes 10.5 minutes 12 minutes 37.8 minutes 28 minutes 1h 10 A 1 minute 7.2 minutes 9 minutes 30.2 minutes 22 minutes 48.6 minutes 12 A - 6 minutes 7 minutes 25.1 minutes 17 minutes 40.3 minutes 14 A - 4.5 minutes 5 minutes 21.6 minutes 15 minutes 33.6 minutes 16 A - 4.1 minutes 4 minutes 18.8 minutes 12.5 minutes 26 minutes 20 A - 2.9 minutes 1 minute 12.9 minutes 9 minutes 19.6 minutes 30 A - - - - 4.6 min 12.1 min 40 A - -- - - 2.8 min 8.5 min 8.4 Table 8- 1 Efficiency SITOP UPS1600 6EP4134-3AB00-0AY0 (10 A) 6EP4134-3AB00-2AY0 (10 A) 6EP4134-3AB00-1AY0 (10 A) Efficiency at Uin rated, Iout rated, approx. 97.5 % 97.3 % Power loss at Uin rated, Iout rated, approx. 6W 7W 6EP4136-3AB00-0AY0 (20 A) 6EP4136-3AB00-2AY0 (20 A) 6EP4136-3AB00-1AY0 (20 A) Efficiency at Uin rated, Iout rated, approx. 97.7 % 97.5 % Power loss at Uin rated, Iout rated, approx. 10 W 11 W 6EP4137-3AB00-0AY0 (40 A) 6EP4137-3AB00-2AY0 (40 A) 6EP4137-3AB00-1AY0 (40 A) Efficiency at Uin rated, Iout rated, approx. 98.5 % 98.3 % Power loss at Uin rated, Iout rated, approx. 15 W 17 W SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 215 Technical data 8.5 Protection and monitoring 8.5 Table 8- 2 Protection and monitoring SITOP UPS1600 Current limitation 6EP4134-3AB00- ... (10 A) 6EP4136-3AB00- ... (20 A) 6EP4137-3AB00- ... (40 A) 30 A 60 A 120 A Typ. * Power boost with 300 % Iout rated Power boost with 300 % Iout rated Power boost with 300 % Iout rated for typ. 30 ms for typ. 30 ms for typ. 30 ms Remark Short-circuit protection Shutdown after 30 ms Reverse polarity protection With respect to the input voltage Uin and with respect to batteries Overload/short-circuit Yes, restart in normal operation indicator Table 8- 3 SITOP UPS1100 6EP41310GB00-... (1.2 Ah) Short-circuit protection Yes, fuse Reverse polarity protection Yes 8.6 6EP41320GB00-... (2.5 Ah) 6EP41330GB00-... (3.2 Ah) 6EP41330JB00-... (5 Ah) 6EP41340GB00-... (7 Ah) 6EP41350GB00-... (12 Ah) MTBF 6EP4134-3AB00- ... (10 A) 6EP4136-3AB00- ... (20 A) 6EP4137-3AB00- ... (40 A) Mean Time Between Failures SN29500: > 320000 h at 40 C, rated load, 24h operation SITOP UPS1600 / UPS1100 216 Manual, 04.2017, A5E37775406-8-76 Technical data 8.7 Mechanical system 8.7 Mechanical system 8.7.1 SITOP UPS1600 Table 8- 4 SITOP UPS1600 10 A / 20 A 6EP4134-3AB00- ... (10 A) ... -0AY0 ... -1AY0 6EP4136-3AB00- ... (20 A) ... -2AY0 ... -0AY0 ... -1AY0 ... -2AY0 Connection system Screw-type terminal Connections / DC input IN+, IN-: 1 screw terminal each for 0.2 - 6 (4) mm solid (finely stranded) Connections / DC output OUT+, OUT-: 1 screw terminal each for 0.2 - 6 (4) mm solid (finely stranded) Connections / BAT BAT+, BAT-: 1 screw terminal each for 0.2 - 6 (4) mm solid (finely stranded) Connections / signal connector X2 (1 - 14): 1 screw terminal each for 0.2 - 1.5 mm solid/finely stranded Width of the housing 50 mm 50 mm 50 mm 50 mm 50 mm 50 mm Height of the housing 138.7 mm 138.7 mm 138.7 mm 138.7 mm 138.7 mm 138.7 mm Depth of the housing 125 mm 125 mm 125 mm 125 mm 125 mm 125 mm Installation width 50 mm 50 mm 50 mm 50 mm 50 mm 50 mm Mounting height 238.7 mm 238.7 mm 238.7 mm 238.7 mm 238.7 mm 238.7 mm Weight, approx. 0.38 kg 0.4 kg 0.44 kg 0.39 kg 0.41 kg 0.45 kg Product feature / of the housing / housing that can be lined up next to one another Yes Type of mounting / wall mounting No Type of mounting / rail mounting Yes Type of mounting / S7-300 rail mounting No Mounting Can be snapped onto standard TH35x7,5/15 mounting rails (EN 60715) Table 8- 5 SITOP UPS1600 40 A 6EP4137-3AB00- ... (40 A) ... -0AY0 ... -1AY0 ... -2AY0 Connection system Screw-type terminal Connections / DC input IN+, IN-: 1 screw terminal each for 0.5 - 16 (4) mm solid (finely stranded) Connections / DC output OUT+, OUT-: 1 screw terminal each for 0.5 - 16 (4) mm solid (finely stranded) Connections / BAT BAT+, BAT-: 1 screw terminal each for 0.5 - 16 (4) mm solid (finely stranded) SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 217 Technical data 8.7 Mechanical system 6EP4137-3AB00- ... (40 A) ... -0AY0 ... -1AY0 ... -2AY0 Connections / signal connector X2 (1 - 14): 1 screw terminal each for 0.2 - 1.5 mm solid/finely stranded Width of the housing 70 mm 70 mm 70 mm Height of the housing 138.7 mm 138.7 mm 138.7 mm Depth of the housing 150 mm 150 mm 150 mm Installation width 70 mm 70 mm 70 mm Mounting height 238.7 mm 238.7 mm 238.7 mm Weight, approx. 0.65 Kg 0.65 Kg 0.7 kg Product feature / of the housing / housing that can be lined up next to one another Yes Type of mounting / wall mounting No Type of mounting / rail mounting Yes Type of mounting / S7-300 rail mounting No Mounting Can be snapped onto standard TH35x7,5/15 mounting rails (EN 60715) 8.7.2 Table 8- 6 SITOP UPS1100 SITOP UPS1100 1.2 Ah / 2.5 Ah / 3.2 Ah 6EP4131-0GB00- ... (1.2 Ah) 6EP4132-0GB00- ... (2.5 Ah) 6EP4133-0GB00- ... (3.2 Ah) Connection system Screw-type terminal Connections / DC input X1-1, X1-2: 1 screw terminal each for 0.2 - 6 (4) mm solid (finely stranded) Connections / signal terminal X2-1, X2-2: 1 screw terminal each for 0.14 - 4 (2.5) mm solid (finely stranded) Width of the housing 89 mm 265 mm 190 mm Height of the housing 130.3 mm 115 mm 169.3 mm Depth of the housing 106.7 mm 76 mm 78.7 mm Installation width 89 mm 265 mm 190 mm Mounting height 145.3 mm 130 mm 184.3 mm Weight, approx. 1.9 kg 3.7 kg 3.8 kg Product feature / of the housing / housing that can be lined up next to one another Yes Type of mounting / wall mounting Yes SITOP UPS1600 / UPS1100 218 Manual, 04.2017, A5E37775406-8-76 Technical data 8.7 Mechanical system 6EP4131-0GB00- ... (1.2 Ah) 6EP4132-0GB00- ... (2.5 Ah) 6EP4133-0GB00- ... (3.2 Ah) Type of mounting / rail mount- Yes ing Type of mounting / S7-300 rail mounting No Mounting Wall mounting, can be snapped onto standard TH35x7,5/15 mounting rails (EN 60715) Table 8- 7 Wall mounting, can be snapped onto standard TH35x15 mounting rails (EN 60715) SITOP UPS1100 7 Ah / 12 Ah 6EP4133-0JB00- ... (5 Ah) 6EP4134-0GB00- ... (7 Ah) 6EP4135-0GB00- ... (12 Ah) Connection system Screw-type terminal Screw-type terminal Connections / DC input X1-1, X1-2: 1 screw terminal X1-1, X1-2: 1 screw terminal each for 0.2 - 16 mm soleach for 0.2 - 6 (4) mm solid id/finely stranded (finely stranded) Connections / signal terminal X2-1, X2-2: 1 screw terminal each for 0.14 - 4 (2.5) mm solid (finely stranded) X2-1, X2-2: 1 screw terminal each for 0.14 - 4 (2.5) mm solid (finely stranded) Width of the housing 189 mm 186 mm 253 mm Height of the housing 186 mm 186 mm 186 mm Depth of the housing 112.7 mm 110.3 mm 110 mm Installation width 189 mm 186 mm 253 mm Mounting height 201 mm 201 mm 201 mm Weight, approx. 3.4 kg 6.1 kg 9.3 kg Product feature / of the housing / housing that can be lined up next to one another Yes Type of mounting / wall mounting Yes Type of mounting / rail mounting Yes Type of mounting / S7-300 rail mounting No Mounting Wall mounting, can be snapped onto standard TH35x15 mounting rails (EN 60715) Wall mounting SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 219 Technical data 8.8 Dimension drawing 8.8 Dimension drawing see Section Dimensions and weight (Page 39) CAD data that can be downloaded from the Internet: 6EP4134-3AB00-0AY0 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00813) 6EP4134-3AB00-1AY0 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00816) 6EP4134-3AB00-2AY0 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00819) 6EP4136-3AB00-0AY0 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00810) 6EP4136-3AB00-1AY0 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00807) 6EP4136-3AB00-2AY0 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00804) 6EP4137-3AB00-0AY0 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_01019) 6EP4137-3AB00-1AY0 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_01022) 6EP4137-3AB00-2AY0 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_01025) 6EP4131-0GB00-0AY0 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00829) 6EP4132-0GB00-0AY0 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_01013) 6EP4133-0GB00-0AY0 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00832) 6EP4134-0GB00-0AY0 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00835) 6EP4135-0GB00-0AY0 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_01016) 6EP4133-0JB00-0AY0 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_01105) SITOP UPS1600 / UPS1100 220 Manual, 04.2017, A5E37775406-8-76 Safety, approvals, EMC 9.1 9 Safety 6EP4134-3AB00- ..., 6EP4136-3AB00- ..., 6EP4137-3AB00- ... 6EP4131-0GB00- ..., 6EP4132-0GB00- ..., 6EP4133-0GB00- ..., 6EP4134-0GB00- ..., 6EP4135-0GB00- ..., 6EP4133-0JB00- ... Protection class Class III Degree of protection (EN 60529) IP20 Test voltage See Table 9-1 Test voltage (Page 222) SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 221 Safety, approvals, EMC 9.2 Test voltage 9.2 Test voltage Figure 9-1 Test voltage diagram Only applicable for UPS1600 with PROFINET (-2AY0). Only the manufacturer can perform the type test and production test; users can also perform the field test. Preconditions for performing the field test: Test (A) Connect the input, output, BAT and signaling contact with one another and measure with respect to PE Test (B) Connect all PROFINET cables and measure with respect to PE (input, output, BAT signal connector and PE are connected with each other) Table 9- 1 Test voltage Type test Production test Field test Test time Input, output, BAT PE (A) PROFINET PE (B) 60 s 700 VDC 2200 VDC 60 s 500 VAC 1500 VAC 1s 200 VDC 1s 140 VAC 1s 200 VDC 2200 VDC 1s 140 VAC 1500 VAC Remark: Tripping current for DC measurement: 0 mA Tripping current for AC measurement: <100 mA SITOP UPS1600 / UPS1100 222 Manual, 04.2017, A5E37775406-8-76 Safety, approvals, EMC 9.3 Approvals 9.3 Approvals 6EP4134-3AB00- ... 6EP4131-0GB00-0AY0 6EP4136-3AB00- ... 6EP4132-0GB00-0AY0 6EP4137-3AB00- ... 6EP4133-0GB00-0AY0 6EP4133-0JB00-0AY0 6EP4134-0GB00-0AY0 6EP4135-0GB00-0AY0 CE marking Yes, (2004/108/EG) Yes, (2004/108/EG and 2006/66/EG) UL/cUL approval cULus-listed (UL 508, CSA 22.2 No. 107.1), File E197259 cURus-Recognized (UL 1778, CSA C22.2 No. 107.1), File E219627 Explosion protection EPS 13 ATEX 1 607 X IECEx EPS 14.0063X II 3G Ex nA nC IIC T4 Gc; cCSAus HazLoc Class I, Div 2, Group A,B,C,D T4; cULus HazLoc Class I, Div 2, Group A,B,C,D T4 EPS 13 ATEX 1 607 X IECEx EPS 14.0063X II 3G Ex nA IIC T4 Gc; cCSAus HazLoc Class I, Div 2, Group A,B,C,D T4; cURus HazLoc Class I, Div 2, Group A,B,C,D T4 6EP4133-0JB00-0AY0: No explosion protection certification CB certification Yes, (IEC 60950-1) Yes, (IEC 60950-1) Marine approvals GL GL 9.4 EMC 6EP4134-3AB00- ... (10 A) 6EP4133-0JB00-0AY0 6EP4136-3AB00- ... (20 A) (5 Ah) 6EP4137-3AB00- ... (40 A) 6EP4131-0GB00-0AY0 (1.2 Ah) 6EP4132-0GB00-0AY0 (2.5 Ah) 6EP4133-0GB00-0AY0 (3.2 Ah) 6EP4134-0GB00-0AY0 (7 Ah) 6EP4135-0GB00-0AY0 (12 Ah) Electrostatic discharge EN 61000-4-2 6 kV contact, 8 kV air Electromagnetic fields EN 61000-4-3 80 - 1000 MHz 10 V/m 5 kV contact, 8 kV air 1400 - 2000 MHz 10 V/m 2000 - 2700 MHz 10 V/m 895 - 905 MHz and 1.89 GHz 10 V/m High-speed transient disturbance variables (burst) EN 61000-4-4 2 kV at DC input/output Surge voltages EN 61000-4-5 500 V symmetrical/unsymmetrical at the DC input/output, 1 kV unsymmetrical at signal connections SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 223 Safety, approvals, EMC 9.4 EMC 6EP4134-3AB00- ... (10 A) 6EP4133-0JB00-0AY0 6EP4136-3AB00- ... (20 A) (5 Ah) 6EP4137-3AB00- ... (40 A) 6EP4131-0GB00-0AY0 (1.2 Ah) 6EP4132-0GB00-0AY0 (2.5 Ah) 6EP4133-0GB00-0AY0 (3.2 Ah) 6EP4134-0GB00-0AY0 (7 Ah) 6EP4135-0GB00-0AY0 (12 Ah) High-frequency fields EN 61000-4-6 10 V; 0.15 - 80 MHz Magnetic fields EN 61000-4-8 Not applicable Emitted interference EN 55022 Class B Generic standards EN 61000-6-2 Immunity for industrial environments EN 61000-6-3 Emission for residential areas SITOP UPS1600 / UPS1100 224 Manual, 04.2017, A5E37775406-8-76 10 Environmental conditions Table 10- 1 UPS1600 6EP4134-3AB00- ... (10 A) Ambient temperature 6EP4136-3AB00- ... (20 A) 6EP4137-3AB00- ... (40 A) -25 ... 70 C for natural convec- -25 ... 60 C for natural convec- -25 ... 60 C for natural convection (self convection) tion (self convection) tion (self convection) 15 A (derating) at 60 ... 70 C 30 A (derating) at 60 ... 70 C Tested according to: * EN 60068-2-1 cold * EN 60068-2-2 dry heat * EN 60068-2-78 humid heat, constant * EN 60068-2-14 temperature change Remark: The service life of the UPS1100 battery modules (decrease to 50 % of the original capacity) depends on the battery temperature, at approximately 20 C: 4 years, 30 C: 2 years, 40 C: 1 year Transport and storage temperature -40 ... 85 C Tests (packed for shipping) according to: * EN 60068-2-1 cold * EN 60068-2-2 dry heat * EN 60068-2-30 humid heat, cyclic Humidity class Climatic class 3K3 according to EN 60721, 5 - 95 % no condensation Degree of pollution 2 Mechanical stress in operation Tested according to: Damaging gases Air pressure * EN 60068-2-6 Vibration, test Fc: 3.5 mm deflection in the range 5 - 9 Hz 1 g acceleration in the range 9 - 150 Hz * EN 60068-2-27 shock, test Ea: acceleration 150 m/s2 , test duration 11 ms Tested according to: * EN 60068-2-42 sulfur dioxide * EN 60068-2-43 hydrogen sulfide Operation: * 1080 - 795 hPa (-1000 - 2000 m) For operation at altitudes of 2000 m up to 6000 m above sea level: output must be derated by -7.5 % / 1000 m or the ambient temperature must be reduced by 5 K / 1000 m see Figure 6-20 Altitude derating (Page 202) Storage: * * 1080 - 660 hPa (-1000 - 3500 m) SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 225 Environmental conditions Table 10- 2 UPS1100 6EP4131-0GB00-0AY0 (1.2 Ah) 6EP4132-0GB00-0AY0 (2.5 Ah) 6EP4133-0JB00-0AY0 (5 Ah) -20 ... 60 C for natural convection (self convection) -20 ... 50 C for natural convection (self convection) 6EP4133-0GB00-0AY0 (3.2 Ah) 6EP4134-0GB00-0AY0 (7 Ah) 6EP4135-0GB00-0AY0 (12 Ah) Ambient temperature 0 ... 40 C for natural convection (self convection) 1.2 / 3.2 / 7 Ah: From product version 3: -15 ... 50 C for natural convection (self convection) 12 Ah: From product version 2: -15 ... 50 C for natural convection (self convection) Tested according to: * EN 60068-2-1 cold * EN 60068-2-2 dry heat * EN 60068-2-78 humid heat, constant * EN 60068-2-14 temperature change Remark: The service life of the UPS1100 battery modules (decrease to 50 % of the original capacity) depends on the battery temperature, at approximately 20 C: 4 years, 30 C: 2 years, 40 C: 1 year Transport and storage temperature -20 ... 50 C -40 ... 60 C -40 ... 60 C Tests (packed for shipping) according to: * EN 60068-2-1 cold * EN 60068-2-2 dry heat * EN 60068-2-30 humid heat, cyclic Humidity class Climatic class 3K3 according to EN 60721, 5 - 95 % no condensation Degree of pollution 2 Mechanical stressing in operation Tested according to: * EN 60068-2-6 Vibration, test Fc: 3.5 mm deflection in the range 5 - 9 Hz 1 g acceleration in the range 9 - 150 Hz * EN 60068-2-27 shock, test Ea: acceleration 150 m/s2 , test duration 11 ms SITOP UPS1600 / UPS1100 226 Manual, 04.2017, A5E37775406-8-76 Environmental conditions 6EP4131-0GB00-0AY0 (1.2 Ah) 6EP4132-0GB00-0AY0 (2.5 Ah) 6EP4133-0JB00-0AY0 (5 Ah) 6EP4133-0GB00-0AY0 (3.2 Ah) 6EP4134-0GB00-0AY0 (7 Ah) 6EP4135-0GB00-0AY0 (12 Ah) Damaging gases Air pressure Tested according to: * EN 60068-2-42 sulfur dioxide * EN 60068-2-43 hydrogen sulfide Operation: * 1080 - 795 hPa (-1000 - 2000 m) * Operation at altitudes of 4000 m above sea level and higher is not permissible (exception, 2.5 Ah). Operation at installation altitudes of 2000 - 6000 m above sea level: output power derating of -7.5 % / 1000 m - or reduction of the ambient temperature by 5 K / 1000 m see Figure 6-20 Altitude derating (Page 202) Storage: * * 1080 - 660 hPa (-1000 - 3500 m) SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 227 Environmental conditions SITOP UPS1600 / UPS1100 228 Manual, 04.2017, A5E37775406-8-76 Environment 11 The devices are in conformance with RoHS. As a rule, only non-silicon precipitating materials are used. Disposal guidelines Packaging and packaging aids can and should always be recycled. The product itself may not be disposed of as domestic refuse. Note The rechargeable batteries must be disposed of, discharged according to the applicable regulations. SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 229 Environment SITOP UPS1600 / UPS1100 230 Manual, 04.2017, A5E37775406-8-76 Service & Support 12 Technical support Technical support for all IA/DT products can be accessed through the following communication channels: Telephone: + 49 (0) 911 895 7222 Internet: Online support request form (http://www.siemens.de/automation/support-request) Technical documentation on the Internet Operating instructions and manuals for SITOP are available in the Internet: Operating instructions/manuals (http://www.siemens.com/sitop/manuals) SITOP power supply homepage General news about our power supplies is available in the Internet at the SITOP home page: SITOP (http://www.siemens.com/sitop) Information material SITOP information can be downloaded from the Internet: Information and download center (http://www.siemens.com/sitop-infomaterial) CAx data 2D/3D data and circuit diagram macros can be downloaded from the Internet: Siemens image database (http://www.siemens.com/sitop-cax) Request all CAx data via the CAx download manager: CAx shopping cart (http://www.siemens.com/cax) SITOP Selection Tool Simply and quickly select the optimum the power supply or DC-UPS: SITOP Selection Tool (http://www.siemens.com/sitop-selection-tool) Online catalog and ordering system The online catalog and the online ordering system are available through the Industry Mall homepage: Industry Mall (http://www.siemens.com/industrymall/de) SITOP UPS1600 / UPS1100 Manual, 04.2017, A5E37775406-8-76 231 Service & Support Contact persons If you have any questions regarding the use of our products, then contact the Siemens contact person in your regional Siemens sales office. You can find these addresses as follows: On the Internet (http://www.automation.siemens.com/partner) In Catalog CA 01 SITOP UPS1600 / UPS1100 232 Manual, 04.2017, A5E37775406-8-76