C171 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708 www.turck.com
Inductive
Sensors
For detailed sensor specifications see Section A.
Normally Closed versions available upon request, consult factory.
Housing Style Part Number ID Number Features
Sensing
Range (mm)
Output
30 mm - Embeddable,
Terminal Chamber
Bi10-G30SK-AN6X2 T4648500 10
3-Wire DC
NPN
Bi10U-EG30SK-AN6X M1636420 Uprox 10
Bi10-G30SK-AP6X2 T4648400 10
3-Wire DC
PNP
Bi10U-EG30SK-AP6X M1636400 Uprox 10
Bi10-G30SK-AZ3X2 T4346400 10
2-Wire AC/DC
30 mm - Nonembeddable,
Terminal Chamber
Ni15-G30SK-AN6X2 T4648700 15
3-Wire DC
NPN
Ni20U-EG30SK-AN6X M1646420 Uprox 20
Ni15-G30SK-AP6X2 T4648600 15
3-Wire DC
PNP
Ni20U-EG30SK-AP6X M1646400 Uprox 20
Ni15-G30SK-AZ3X2 T4346500 15
2-Wire AC/DC
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708 www.turck.com C172
Industrial
Automation
Barrels
For material descriptions see page A34.
Industrial
Automation
TURCK mold-on connectors available
on all cable sensors. See page A5.
Voltage
Switching
Freq. (Hz)
Operating
Current (mA)
AC/DC
Operating
Temp. (°C)
Protection
Housing
Face
End Cap
Power LED
Output LED
Cable Length/
Cable Mat.
Wiring
Diagram #
Wiring Diagrams
10-30 VDC
500 200 -25 to +70 IP 67 CPB PA 12 N/A GN YE - - - - 1
2000 200 -30 to +85 IP 68 SS PA 12 N/A N/A YE - - - - 1
10-30 VDC
500 200 -25 to +70 IP 67 CPB PA 12 N/A GN YE - - - - 2
2000 200 -30 to +85 IP 68 SS PA 12 N/A N/A YE - - - - 2
20-250 VAC
10-300 VDC
20 400/300 -25 to +70 IP 67 CPB PA 12 N/A GN Rd - - - - 3
10-30 VDC
500 200 -25 to +70 IP 67 CPB PA 12 N/A GN YE - - - - 1
1500 200 -30 to +85 IP 68 SS PA 12 N/A N/A YE - - - - 1
10-30 VDC
500 200 -25 to +70 IP 67 CPB PA 12 N/A GN YE - - - - 2
1500 200 -30 to +85 IP 68 SS PA 12 N/A N/A YE - - - - 2
20-250 VAC
10-300 VDC
20 400/300 -25 to +70 IP 67 CPB PA 12 N/A GN Rd - - - - 3
Diagram 1
Diagram 2
Diagram 3