3/10/2013
IFRR 18N17T1/S14L-9
Inductive proximity switch
Inductive sensors
www.baumer.com
general data
mounting type quasi-flush
special type Washdown design
nominal sensing distance Sn 8 mm
hysteresis 2 ... 15 % of Sr
output indicator LED red
approvals/certificates Ecolab
electrical data
switching frequency < 500 Hz
voltage supply range +Vs 10 ... 30 VDC
current consumption max. (no load) 10 mA
output circuit NPN make function (NO)
voltage drop Vd < 2 VDC
output current < 200 mA
output current (at cleaning temperature) < 100 mA
short circuit protection yes
reverse polarity protection yes
mechanical data
type cylindrical threaded
material (sensing face) LCP
housing material stainless steel 1.4404 (V4A); LSR
dimension 18 mm
housing length 60 mm
connection types connector M12
ambient conditions
operating temperature -40 ... +80 °C
cleaning temperature 80 ... +100 °C (30 min/day)
protection class IP 68/69K & proTect+
photo
dimension drawing
SW 24
LED
43
60
M18 x 1
M12 x 1
connection diagram
output
+VS
BU (3) 0 V
BN (1)
NPN BK (4) Z
Sensor FDA compliant and Ecolab
approved
LSR = Liquid Silicon Rubber