| 17 A-Series Rocker UL Recognized – Ordering Scheme
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
6
Frequency
& Delay
7
Current Rating
8
Terminal
9
Actuator
Color
10
Mounting/
Barriers
11
Agency
Approval
4
Circuit
A F B 2 11 0 3 D24 630
1 SERIES
A
2 ACTUATOR1
Two Color Visi-Rocker
C Indicate ON, vertical legend
D Indicate ON, horizontal legend
E Indicate ON, no legend
F Indicate OFF, vertical legend
G Indicate OFF, horizontal legend
H Indicate OFF, no legend
Push-To-Reset, Visi-Rocker
N Indicate OFF,
vertical legend
O Indicate OFF,
horizontal legend
P Indicate OFF,
no legend
Single color
J Vertical legend
K Horizontal legend
L No legend
Push-To-Reset , Single color
R Vertical legend
U Horizontal legend
V No legend
10 MOUNTING/BARRIERS20
STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole BARRIERS
1 6-32 x 0.195 inches no
A 6-32 X 0.195 inches (multi-pole units only) yes
2 ISO M3 x 5mm no
B ISO M3 x 5mm (multi-pole units only) yes
ROCKERGUARD & PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole
3 6-32 x 0.195 inches no
C 6-32 x 0.195 inches (multi-pole units only) yes
4 ISO M3 x 5mm no
D ISO M3 x 5mm (multi-pole units only) yes
FRONT PANEL SNAP-IN BRACKET, 0.744” wide bezel
8 without Rockerguard (single pole units only) no
H with Rockerguard (single pole units only) no
FRONT PANEL SNAP-IN BRACKET, 0.96” wide bezel
9 without Rockerguard (single pole units only) no
J with Rockerguard (single pole units only) no
3 POLES
1 One 2 Two 3 Three
6 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
10 DC Instantaneous
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
20 50/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
30 DC, 50/60Hz Instantaneous
31 DC, 50/60Hz Ultra Short
32 DC, 50/60Hz Short
34 DC, 50/60Hz Medium
36 DC, 50/60Hz Long
429 50/60Hz Short, Hi-Inrush
449 50/60Hz Medium, Hi-Inrush
469 50/60Hz Long, Hi-Inrush
529 DC, Short,Hi-Inrush
549 DC, Medium, Hi-Inrush
569 DC, Long, Hi-Inrush
11 AGENCY APPROVAL
C UL Recognized & CSA Accepted
D VDE Certied, UL Recognized & CSA Accepted
E TUV Certied, UL Recognized & CSA Accepted
I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted
9 ACTUATOR COLOR & LEGEND
Actuator or Marking: Marking Color
Visi-Color12 I-O ON-OFF Dual12 Single Color Visi-Rocker
White A B 1 Black White
Black C D 2 White n/a
Red F G 3 White Red
Green H J 4 White Green
Blue K L 5 White Blue
Yellow M N 6 Black Yellow
Gray P Q 7 Black Gray
Orange R S 8 Black Orange
Notes:
1 Push-To-Reset actuators have OFF portion of rocker shrouded.
2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed
poles, and have one rocker per breaker.
3 Switch Only circuits, rated up to 50 amps & 3 poles, are available only when tied to a protected
pole (Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630.
For 35 - 50 amps, select Current Code 650.
4 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
5 Consult factory for Dual Coil options, as special catalog number is required.
With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require
30VA minimum power to trip and are rated for intermittent duty only.
6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with
standard half shells. 30-50A are supplied with extended boat (B-Style) half shells.
7 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole.
8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes
10 and 20.
9 Available with Circuit Codes B & D only. VDE Certied to 30 amps. UL Recognized, CSA
Accepted & TUV Certied to 50 amps.
10 Series Trip current ratings: VDE Certication available with single pole breakers with DC Delay
only. UL Recognition & CSA Accepted available in one and two pole breakers.
11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are
only available with Terminal Codes 5, 9, G, H, M and Q.
12 Terminal Code 1: VDE Certication up to 25 amps and UL Recognition and CSA Accepted up to
30 amps, but not recommended over 20 amps.
13 Terminal Codes 3, 5 E & H (Bus Type) with VDE, are supplied with Lock Washers; Terminal Code
M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are
only VDE Certied when the washers are used.
14 VDE Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps.
15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps
with VDE Certication and 50 amps with UL Recognition and CSA Accepted, with Circuit Codes
A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to
40 amps with UL Recognition and CSA Certication with Circuit Codes A, B and C.
16 Terminal Code Q not available with VDE.
17 Terminal Code S used on voltage coil circuit constructions only.
18 Color shown is visi and legend with remainder of rocker black.
19 Dual = ON-OFF/I-O legend with actuator. None = no legend on actuator
20 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R, & U. Legend
on Push-to-reset bezel/shroud matches Visi-color of rocker with actuator codes N & O.
Rockerguard available with actuator codes C through L.
4 CIRCUIT
A3 Switch Only (No Coil)
B Series Trip (Current)
C Series Trip (Voltage)
D4 Shunt Trip (Current)
E4 Shunt Trip (Voltage)
F4 Relay Trip (Current)
G4 Relay Trip (Voltage)
H4,5 Dual Coil with Shunt Trip
Voltage Coil
K4,5 Dual Coil with Relay Trip
Voltage Coil
5 AUXILIARY/ALARM
SWITCH6,7
0 w/o Aux Switch
1 S.P.D.T., 0.093 Q.C. Term.
2 S.P.D.T., 0.110 Q.C. Term.
3 S.P.D.T., 0.139 Solder Lug
4 S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
5 S.P.S.T., 0.093 Q.C. Term.
(Gold Contacts)
6 S.P.S.T., 0.139 Solder Lug
7 S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
8 S.P.S.T., 0.187 Q.C. Term.
9 S.P.D.T., 0.187 Q.C. Term.
7 CURRENT RATING (AMPERES)
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)8
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
63510 35.000
64010 40.000
64510 45.000
65010 50.000
CODE AMPERES
A06 6 DC
A12 12 DC
A18 18 DC
A24 24 DC
A32 32 DC
A48 48 DC
A65 65 DC
J06 6 AC
J12 12 AC
J18 18 AC
J24 24 AC
J48 48 AC
J65 65 AC
K20 120 AC
L40 240 AC
8 TERMINAL11
112 Push-On 0.250 Tab (Q.C.)
2 Screw 8-32 w/upturned lugs
313 Screw 8-32 (Bus Type)
4 Screw 10-32 w/upturned lugs
513 Screw 10-32 (Bus Type)
6 Screw 8-32 w/upturned lugs
and 30° bend
7 Screw 8-32 (Bus Type) and
30° bend
8 Screw 10-32 w/upturned lugs
and 30° bend
9 Screw 10-32 (Bus Type) and
30° bend
B Screw M5 w/upturned lugs
C Screw M4 w/upturned lugs
E13 Screw M4 (Bus Type)
F Screw M5 w/upturned lugs
and 30° bend
G Screw M5 (Bus Type)
and 30° bend
H13 Screw M5 (Bus Type)
L14 0.250 Q.C./ Solder Lug
M13 M6 Threaded Stud
P15 Printed Circuit BoardTerminals
Q16 Push-In Stud
R Screw M4 w/upturned lugs
and 30° bend
S17 Push-On 0.110 Tab (Q.C.)
T Screw M4 (Bus Type)
and 30° bend