A-Series Circuit Breaker Well known for their proven reliability, the A-Series hydraulic/ magnetic circuit breakers are compact, temperature stable and designed for precision operation in OEM markets requiring general purpose as well as full load amp applications. The A-Series circuit breakers are offered with ratings from 0.02 to 50 amps, up to 277VAC or 80VDC and are available with several choices of pole configurations, time delays, terminals, with a wide range of standard colors, imprinting and actuator styles. Actuator styles include handle for 1-6 poles and rocker for 1-3 pole construction. When front panel operation and aesthetics demand a clean, contemporary design, a two-color or solid color Visi-Rocker actuator, indicating either the ON mode or the TRIPPED/OFF mode, is ideally suitable. The new Rockerguard bezel and push-to-reset bezel, which help prevent inadvertent actuation, is also available. Features: Specially constructed version available for applications requiring CE markings The metal toggle option was tested to MIL-PRF-55629C for ingress protection when mounted in a panel, and also meets IP68 requirement. Applications: Marine Telecommunications Military Renewable Energy Systems Generators & Welder Carling Technologies, Inc. 60 Johnson Avenue * Plainville, CT 06062 Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 1 POLE - PUSH TO RESET 2 POLE - HANDLE 1 POLE - TOGGLE Agency Certifications: UL Recognized - UL Standard 508, 1077, 1500 UL Listed - UL Standard 489A CSA Accepted TUV Certified VDE Certified 2 | A-Series Circuit Breaker - General Specifications Electrical Mechanical Maximum Voltage Current Ratings Endurance 277VAC 50/60 Hz, 80VDC Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 35.0, 40.0, 50.0. Other ratings available - consult ordering scheme. Standard Voltage Coils DC-6V, 12V; AC-120V, Other ratings available, consult ordering scheme. Auxiliary Switch Rating SPDT; 10.1 A - 250VAC, 1.0 A-65VDC/0.5 A - 80 VDC, 0.1A - 125VAC (with gold contacts). Insulation Resistance Minimum: 100 Megohms at 500 VDC Dielectric Strength UL, CSA - 1500V 60 Hz for one minute between all electrically isolated terminals. A-Series rocker circuit breakers comply with the 8mm spacing & 3750V dielectric requirements from hazardous voltage to operator accessible surfaces per EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker. RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) Trip Free Trip Indication 10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage. All A-Series Circuit Breakers will trip on overload, even when the actuator is forcibly held in the ON position. The operating actuator moves positively to the OFF position when an overload causes the circuit breaker to trip. When mid-trip handle is specified, the handle moves to the mid position on electrical trip of the circuit breaker. When mid-trip handle with alarm switch is specified, the handle moves to the mid position & the alarm switch actuates when the circuit breaker is electrically tripped. Physical Number of Poles 1 - 6 Poles (handle) and 1-3 poles (rocker) at 30 Amps or less. 1 and 2 poles at 31 Amps thru 50 Amps. Internal Circuit Config. Series, (with or without auxiliary switch), Shunt and Relay with current or voltage trip coils, Dual Coil, Switch Only with or without auxiliary switch. Weight Approximately 65 grams/pole. (Approximately 2.32 ounces/pole) Standard Colors Housing - Black; Actuator- See Ordering Scheme. Environmental Pulse Tolerance Curves Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition "I". Instantaneous and ultra-short curves tested @ 90% of rated current. Vibration Withstands 0.060" excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D; ten 24-hour cycles @ + 25C to +65C, 80-98% RH.56 days @ +85C, 85% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55C to +25C to +85C to +25C). Operating Temperature -40 C to +85 C *Manufacturer reserves the right to change product specification without prior notice. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com A-Series Circuit Breaker - General Specifications | 3 Electrical Tables Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector. Handle Notes: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 2 Same as note 1, except that backup fuse is limited to 80 A maximum. 3 2 pole protector required (with one pole per power line) for: 125/250 VAC, 1 pole protector required for : 125 VAC, 1O Power System. 4 Satisfies the requirements of clause 11.2.8.2.5 of CSA STD C22.2 No 100 for the use of supplementary protectors with portable generators. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 4 | A-Series Circuit Breaker - General Specifications Electrical Tables Table B: Lists UL Recognized, CSA Accepted, VDE & TUV Certified configurations & performance capabilities as a Component Supplementary Protector. 1 3 2 3 2 3 2 Notes: 1 General Purpose Ratings for UL/CSA Only. 2 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 3 Same as note 2, except that backup fuse is limited to 80 A maximum. 4 Satisfies the requirements of clause 11.2.8.2.5 of CSA STD C22.2 No 100 for the use of supplementary protectors with portable generators. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com A-Series Circuit Breaker - General Specifications | 5 Electrical Tables Table C: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. A-SERIES TABLE C: UL1500 (Marine Ignition Protected) VOLTAGE CIRCUIT CONFIGURATION CURRENT RATING SHORT CIRCUIT CAPACITY (AMPS) APPLICATION CODES MAX. RATING FREQUENCY PHASE FULL LOAD AMPS WITHOUT BACKUP FUSE UL CSA 14 1 DC --- 0.02 - 50 5000 TC1,OL1,U1 TC1,OL1,U1 32 1 65 DC --- 0.02 - 50 5000 TC1,OL1,U2 TC1,OL1,U2 DC --- 0.02 - 50 3000 TC1,OL1,U1 TC1,OL1,U1 125 50 / 60 1 0.02 - 50 3000 TC1,OL1,U2 TC1,OL1,U2 125 / 250 50 / 60 12 0.02 - 50 3000 TC1,OL1,U2 TC1,OL1,U2 250 50 / 60 1 0.02 - 30 1500 TC1,OL1,U1 TC1,OL1,U1 SERIES Notes: Notes: 1 Available with special catalog number only (consult factory). 2 2 pole protector required (with one per Special power line) for 125 /Number 250 VAC.Only 1 pole(consult protectorfactory) required for 125 VAC 1 phase power system 1 Available with Catalog 2 2 pole protector required (with one per power line) for 125 / 250 VAC. 1 pole protector required for 125 VAC 1 phase power system Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (Guide DITT, File E189195), under UL489A. Notes: 1 Parallel Pole Construction Agency Certifications UL Recognized UL Standard 1077 Component Recognition Program as Protectors Supplementary (Guide CCN/QVNU2, File E75596) CSA Accepted Component Supplementary Protector under Class 3215 30, File 047848 0 000 CSA Standard C22.2 No. 235 UL Standard 508 Switches, Industrial Control (Guide CCN/NRNT2, File E148683) TUV Certified EN60934, under License No. R72040875 UL Standard 1500 Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection VDE Certified EN60934, VDE 0642 under File No. 10537 UL Listed UL Standard 489A Communications Equipment (Guide CCN/DITT, File E189195) 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 6 | A-Series Handle UL Recognized - Ordering Scheme A A 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 10 5 Aux/Alarm Switch 6 Frequency & Delay 1 SERIES A 2 ACTUATOR A B S T 1 Handle, one per pole Handle, one per multipole unit Mid-Trip Handle, one per pole Mid-Trip Handle, one per pole & Alarm Switch 3 4 One Two 5 6 Three Four Switch Only (No Coil) Series Trip (Current) Series Trip (Voltage) Shunt Trip (Current) Shunt Trip (Voltage) F3 G3 H3,4 K3,4 Five Six Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 095 210 215 220 5 AUXILIARY/ALARM SWITCH5 w/o Aux Switch S.P.D.T., 0.093 Q.C. Term. S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 03 10 11 12 14 16 20 21 22 24 26 10 Mounting/ Barriers DC 50/60Hz, Switch Only DC Instantaneous DC Ultra Short DC Short DC Medium DC Long 50/60Hz Instantaneous 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 50/60Hz Long 5 6 7 8 9 30 31 32 34 36 427 447 467 527 547 567 S.P.S.T., 0.093 Q.C. Term. (Gold Contacts) S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. DC, 50/60Hz Instantaneous DC, 50/60Hz Ultra Short DC, 50/60Hz Short DC, 50/60Hz Medium DC, 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units. B: Handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles 5 pole - three handles at center poles 6 pole - four handles at center poles S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C. 2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 50A amps maximum. 4 Consult factory for available Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 5 Auxiliary Switch breakers with Series Trip & Switch Only circuits: 30A - supplied with standard half shells. 35-50A - supplied with extended boat (B-Style) half shells. On multi-pole breakers, one auxilary switch is supplied, mounted in the extreme right pole. 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 8 VDE Certification available with single pole breakers with DC Delay only. UL Recognition and CSA Accepted available in one and two pole breakers. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q.. 10 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA Certification up to 30 amps, but not recommended over 20 amps. 11 Terminal Codes 3, 5, E and H (Bus Type) with VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used. 12 Terminal Code L: VDE Certified available up to 12A. UL Recognized & CSA Accepted available up to 30A. 13 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL Recognition and CSA Accepted, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Accepted with Circuit Codes A, B and C. 14 Terminal Code Q not available with VDE certification. 15 Single pole only. AMPERES 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.060 0.065 0.070 0.075 0.080 0.085 0.090 0.095 0.100 0.150 0.200 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 410 512 415 517 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 1.250 1.500 1.750 11 Agency Approval 420 522 527 430 435 440 445 450 455 460 465 470 475 480 485 490 495 610 710 2.000 2.250 2.750 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 611 711 612 712 613 614 615 616 617 618 620 622 624 625 630 6358 6408 6458 6508 J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC J65 65 AC K20 120 AC L40 240 AC OR VOLTAGE COIL (NORMAL RATED VOLTAGE)6 CODE 0 1 2 3 4 8 9 Terminal Actuator Color C 7 CURRENT RATING (AMPERES) 4 CIRCUIT A2 B C D3 E3 1 B 1 7 Current Rating CODE 3 POLES 1 2 450 AMPERES A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC 8 TERMINAL9 110 2 311 4 511 6 7 8 9 B C Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) Screw 10-32 w/upturned lugs Screw 10-32 (Bus Type) Screw 8-32 w/upturned lugs and 30 bend Screw 8-32 (Bus Type) and 30 bend Screw 10-32 w/upturned lugs and 30 bend Screw 10-32 (Bus Type) and 30 bend Screw M5 w/upturned lugs Screw M4 w/upturned lugs 9 ACTUATOR COLOR & LEGEND Actuator Color I-O White A Black C Red F Green H Blue K Yellow M Gray P Orange R 15 Black (short handle) T E11 F G H11 L12 M11 Q14 R T11 P13 S13 ON-OFF B D G J L N Q S U 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 Screw M4 (Bus Type) Screw M5 w/upturned lugs and 30 bend Screw M5 (Bus Type) and 30 bend Screw M5 (Bus Type) 0.250 Q.C./ Solder Lug M6 Threaded Stud Push-In Stud Screw M4 w/upturned lugs and 30 bend Screw M4 (Bus Type) and 30 bend Printed Circuit Board Terminals Push-On 0.110 Tab (Q.C.) Dual 1 2 3 4 5 6 7 8 9 Legend Color Black White White White White Black Black Black White 10 MOUNTING/BARRIERS 1 A 2 B 5 6 7 8 MOUNTING STYLEBARRIERS Threaded Insert, 2 per pole 6-32 x 0.195 inches no 6-32 x 0.195 inches yes ISO M3 x 5mm no ISO M3 x 5mm (multipole only) yes Front panel Snap-In, 0.75" wide bezel without Handleguardno without Handleguard (multipole only) yes Front panel Snap-In, 0.96" wide bezel without Handleguard, 1-pole 0.96" wide; no multipole units have .105" bezel overhang on all sides without Handleguard, 1-pole 0.96" wide; yes (multipole only) .105" bezel overhang on all sides 11 AGENCY APPROVAL C UL Recognized & CSA Accepted D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com A-Series Handle UL489A - Ordering Scheme | 7 A A 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 14 6 Frequency & Delay 2 ACTUATOR1 Handle, one per pole Mid-Trip Handle, one per pole Mid-Trip Handle, one per pole & Alarm Switch 3 POLES2 1 2 3 4 One Two Three Four Series Trip (Current) 5 AUXILIARY/ALARM SWITCH 0 1 2 3 2 w/o Aux Switch S.P.D.T., 0.093 Q.C. Term. S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug 6 FREQUENCY & DELAY 11 12 14 16 DC Ultra Short DC Short DC Medium DC Long 7 8 9 S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 AMPERES 0.100 0.150 0.200 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 8 TERMINAL5 16 2 37 4 57 6 7 8 1 A 2 B 5 6 7 523 543 563 DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush 10 Mounting/ Barriers Dual 1 2 3 4 5 6 7 8 9 M T 11 Max. Appl. Rating 12 Agency Approval Legend Color Black White White White White Black Black Black White 8 MOUNTING STYLEBARRIERS Threaded Insert, 2 per pole 6-32 x 0.195 inches no 6-32 x 0.195 inches yes ISO M3 x 5mm no ISO M3 x 5mm (multipole only) yes Front panel Snap-In, 0.75" wide bezel without Handleguardno without Handleguard (multipole only) yes Front panel Snap-In, 0.96" wide bezel without Handleguard, 1-pole 0.96" wide; no multipole units have .105" bezel overhang on all sides without Handleguard, 1-pole 0.96" wide; yes (multipole only) .105" bezel overhang on all sides 11 MAXIMUM APPLICATION RATING M 7 CURRENT RATING (AMPERES) CODE 9 Actuator Color 10 MOUNTING/BARRIERS 4 CIRCUIT B 1 B 1 8 Terminal 9 ACTUATOR COLOR & LEGEND Actuator Color ON-OFF White B Black D Red G Green J Blue L Yellow N Gray Q Orange S Black (short handle)10 U 1 SERIES A A S T 450 7 Current Rating 285 290 295 410 512 415 517 420 522 527 430 435 440 445 450 0.850 0.900 0.950 1.000 1.250 1.500 1.750 2.000 2.250 2.750 3.000 3.500 4.000 4.500 5.000 Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) Screw 10-32 w/upturned lugs Screw 10-32 (Bus Type) Screw 8-32 w/upturned lugs and 30 bend Screw 8-32 (Bus Type) and 30 bend Screw 10-32 w/upturned lugs and 30 bend 455 460 465 470 475 480 485 490 495 610 710 611 711 612 712 9 B F G H M7 P8 Q9 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 11.000 11.500 12.000 12.500 613 614 615 616 617 618 620 622 624 625 630 6353 6403 6453 6503 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 Screw 10-32 (Bus Type) and 30 bend Screw M5 w/upturned lugs Screw M5 w/upturned lugs and 30 bend Screw M5 (Bus Type) and 30 bend Screw M5 (Bus Type) M6 Threaded Stud Printed Circuit Board Terminals Push-In Stud 80 DC 12 AGENCY APPROVAL T K J UL489A LISTED UL489A LISTED, VDE CERTIFIED UL489A LISTED, TUV CERTIFIED Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. 2 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 3 VDE Certified to 30 amps. UL489A Listed to 50 amps. 4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9 G, H, M and Q. 6 Terminal Code 1 (Push-On) available up to 25 amps with VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps. 7 Terminal Codes 3, 5 and H (Bus Type) with VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used. 8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Single pole only. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 8 | A-Series Handle WORLD - Ordering Scheme A A 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 110 2 311 4 511 6 2 ACTUATOR1 Handle, one per pole Handle, one per multi-pole unit Mid-Trip Handle, one per pole Mid-Trip Handle, one per pole & Alarm Switch 3 4 One Two D3 E3 H3,4 Switch Only (No Coil) Series Trip (Current) Series Trip (Voltage) 5 AUXILIARY/ALARM SWITCH5 0 2 3 w/o Aux Switch S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug 6 FREQUENCY & DELAY 03 10 11 12 14 16 20 21 22 24 26 5 6 Three Four 4 CIRCUIT A2 B C 7 8 3 POLES 1 2 7 Current Rating DC 50/60Hz, Switch Only DC Instantaneous DC Ultra Short DC Short DC Medium DC Long 50/60Hz Instantaneous 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 50/60Hz Long 9 Five Six Shunt Trip (Current) Shunt Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 30 31 32 34 36 427 447 467 527 547 567 DC, 50/60Hz Instantaneous DC, 50/60Hz Ultra Short DC, 50/60Hz Short DC, 50/60Hz Medium DC, 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 AMPERES 0.100 0.150 0.200 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 285 290 295 410 512 415 517 420 522 527 430 435 440 445 450 0.850 0.900 0.950 1.000 1.250 1.500 1.750 2.000 2.250 2.750 3.000 3.500 4.000 4.500 5.000 455 460 465 470 475 480 485 490 495 610 710 611 711 612 712 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 11.000 11.500 12.000 12.500 613 614 615 616 617 618 620 622 624 625 630 6358 6408 6458 6508 A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC J65 65 AC K20 120 AC L40 240 AC OR VOLTAGE COIL (NORMAL RATED VOLTAGE)6 CODE AMPERES A06 6 DC A12 12 DC A18 18 DC A24 24 DC 9 Actuator Color 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) Screw 10-32 w/upturned lugs Screw 10-32 (Bus Type) Screw 8-32 w/upturned lugs and 30 bend Screw 8-32 (Bus Type) and 30 bend Screw 10-32 w/upturned lugs and 30 bend Screw 10-32 (Bus Type) and 30 bend 9 ACTUATOR COLOR & LEGEND Actuator Color I-O White A Black C Red F Green H Blue K Yellow M Gray P Orange R 10 Mounting/ Barriers B C E11 F G H11 R T11 Dual 1 2 3 4 5 6 7 8 P 11 Agency Approval Screw M5 w/upturned lugs Screw M4 w/upturned lugs Screw M4 (Bus Type) Screw M5 w/upturned lugs and 30 bend Screw M5 (Bus Type) and 30 bend Screw M5 (Bus Type) Screw M4 w/upturned lugs and 30 bend Screw M4 (Bus Type) and 30 bend Legend Color Black White White White White Black Black Black 10 MOUNTING/BARRIERS 1 A 2 B 5 6 7 8 7 CURRENT RATING (AMPERES) CODE 1 A 1 8 Terminal 8 TERMINAL9 1 SERIES A A B S T 450 6 Frequency & Delay MOUNTING STYLEBARRIERS Threaded Insert, 2 per pole 6-32 x 0.195 inches no 6-32 x 0.195 inches yes ISO M3 x 5mm no ISO M3 x 5mm (multipole only) yes Front panel Snap-In, 0.75" wide bezel without Handleguardno without Handleguard (multipole only) yes Front panel Snap-In, 0.96" wide bezel without Handleguard, 1-pole 0.96" wide; no multipole units have .105" bezel overhang on all sides without Handleguard, 1-pole 0.96" wide; yes (multipole only) .105" bezel overhang on all sides 11 AGENCY APPROVAL P TUV Certified, UL Recognized & CSA Accepted Q UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, and H. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C. 2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a protected pole (Circuit Code B, C, D or H.), For .01 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 4 Consult factory for available Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 5 On multi-pole breakers, one auxilary switch is supplied, mounted in the extreme right pole. 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10, 20 & 30. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 8 Available up to two poles with AC or DC delays. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G and H. 10 Terminal Code 1: TUV Certification up to 30 amps, but not recommended over 20 amps. 11 Terminal Codes 3, 5 , 7, 9, E, G and H (Bus Type) are supplied with Lock Washers. These breakers are only TUV Certified when the washers are used. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com A-Series Rocker UL 489A - Ordering Scheme | 9 A F 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 6 Frequency & Delay 1 SERIES A 450 7 Current Rating 1 3 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers 8 TERMINAL5 2 ACTUATOR1 Two Color Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend Single color J Vertical legend K Horizontal legend Push-To-Reset, Visi-Rocker N Indicate OFF, vertical legend O Indicate OFF, horizontal legend Push-To-Reset , Single color R Vertical legend U Horizontal legend 16 2 37 4 57 6 7 8 Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) Screw 10-32 w/upturned lugs Screw 10-32 (Bus Type) Screw 8-32 w/upturned lugs and 30 bend Screw 8-32 (Bus Type) and 30 bend Screw 10-32 w/upturned lugs and 30 bend 9 B F G H M7 P8 Q9 M T 11 Max. Appl. Rating 12 Agency Approval Screw 10-32 (Bus Type) and 30 bend Screw M5 w/upturned lugs Screw M5 w/upturned lugs and 30 bend Screw M5 (Bus Type) and 30 bend Screw M5 (Bus Type) M6 Threaded Stud Printed Circuit Board Terminals Push-In Stud 9 ACTUATOR COLOR & LEGEND Actuator or Visi-Color10 White Black Red Green Blue Yellow Gray Orange 2 One 3 Two Three 1 A 2 B 4 CIRCUIT B Series Trip (Current) 5 AUXILIARY/ALARM SWITCH3 0 1 2 3 w/o Aux Switch S.P.D.T., 0.093 Q.C. Term. S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug 6 FREQUENCY & DELAY 11 12 14 16 DC Ultra Short DC Short DC Medium DC Long 7 8 9 S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 52 54 56 DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 AMPERES 0.100 0.150 0.200 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 3 C 4 D 8 H 9 J STANDARD ROCKER BEZEL BARRIERS Threaded Insert, 2 per pole 6-32 x 0.195 inches no 6-32 X 0.195 inches (multi-pole units only) yes ISO M3 x 5mm no ISO M3 x 5mm (multi-pole units only) yes ROCKERGUARD & PUSH-TO-RESET BEZEL Threaded Insert, 2 per pole 6-32 x 0.195 inches no 6-32 x 0.195 inches (multi-pole units only) yes ISO M3 x 5mm no ISO M3 x 5mm (multi-pole units only) yes FRONT PANEL SNAP-IN BRACKET, 0.744" [18.90mm] wide bezel without Rockerguard (single pole units only) no with Rockerguard (single pole units only) no FRONT PANEL SNAP-IN BRACKET, 0.96" [24.48mm] wide bezel without Rockerguard (single pole units only) no with Rockerguard (single pole units only) no 11 MAXIMUM APPLICATION RATING M 7 CURRENT RATING (AMPERES) CODE Marking Color Single Color Visi-Rocker Black White White n/a White Red White Green White Blue Black Yellow Black Gray Black Orange 10 MOUNTING/BARRIERS11 3 POLES2 1 Marking: ON-OFF Dual10 B 1 D 2 G 3 J 4 L 5 N 6 Q 7 S 8 285 290 295 410 512 415 517 420 522 527 430 435 440 445 450 0.850 0.900 0.950 1.000 1.250 1.500 1.750 2.000 2.250 2.750 3.000 3.500 4.000 4.500 5.000 455 460 465 470 475 480 485 490 495 610 710 611 711 612 712 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 11.000 11.500 12.000 12.500 613 614 615 616 617 618 620 622 624 625 630 6354 6404 6454 6504 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 80 DC 12 AGENCY APPROVAL T K J UL489A LISTED UL489A LISTED, VDE CERTIFIED UL489A LISTED, TUV CERTIFIED Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 3 Auxiliary Switch breakers with Series Trip circuits: 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 6 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps. 7 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used. 8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend. 11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through K 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 10 | A-Series Handle - Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance .020 [.51] unless otherwise specified. 3 Alarm Switch available with .110 x .020 Q.C. & Solder Lug Terminals Only. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com A-Series Handle - Circuit & Terminal Diagrams | 11 Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance .020 [.51] unless otherwise specified. 3 Alarm Switch available with .110 x .020 QC & solder lug terminals only. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 12 | A-Series Handle - Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance 0.20 [.51] unless otherwise specified. 3 For agency code P = .150 [3.81]. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com A-Series Handle - Front Panel Snap-In Mounting Style 5 | 13 Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance .020 [.51] unless otherwise specified. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 14 | A-Series Handle - Front Panel Snap-In Mounting Style 7 Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance .020 [.51] unless otherwise specified. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com A-Series Sealed Toggle UL Recognized - Ordering Scheme | 15 A M 1 1 Series 2 Actuator 3 Poles B 0 4 Circuit 10 5 Aux/Alarm Switch 450 6 Frequency & Delay 7 Current Rating 8 TERMINAL9 1 SERIES A 2 ACTUATOR1 110 2 3 4 5 6 3 POLES 7 M 1 2 3 Sealed Toggle, one per unit One Two Three 8 9 4 CIRCUIT A2 B C D3 E3 F3 G3 H3,4 Switch Only (No Coil) Series Trip (Current) Series Trip (Voltage) Shunt Trip (Current) Shunt Trip (Voltage) K3,4 5 AUXILIARY/ALARM SWITCH5 0 1 2 3 4 w/o Aux Switch S.P.D.T., 0.093 Q.C. Term. S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 03 10 11 12 14 16 20 21 22 24 26 DC 50/60Hz, Switch Only DC Instantaneous DC Ultra Short DC Short DC Medium DC Long 50/60Hz Instantaneous 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 50/60Hz Long 5 6 7 8 9 B C S.P.S.T., 0.093 Q.C. Term. (Gold Contacts) S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 10 MOUNTING/BARRIERS DC, 50/60Hz Instantaneous DC, 50/60Hz Ultra Short DC, 50/60Hz Short DC, 50/60Hz Medium DC, 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 095 210 215 220 AMPERES 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.060 0.065 0.070 0.075 0.080 0.085 0.090 0.095 0.100 0.150 0.200 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 410 512 415 517 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 1.250 1.500 1.750 420 522 527 430 435 440 445 450 455 460 465 470 475 480 485 490 495 610 710 2.000 2.250 2.750 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 611 711 612 712 613 614 615 616 617 618 620 622 624 625 630 6358 6408 6458 6508 J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC J65 65 AC K20 120 AC L40 240 AC OR VOLTAGE COIL (NORMAL RATED VOLTAGE)6 CODE AMPERES A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 9 Actuator Color E F G H L12 M Q R T P12 S 10 Mounting/ Barriers C 11 Agency Approval Screw M4 (Bus Type) Screw M5 w/upturned lugs and 30 bend Screw M5 (Bus Type) and 30 bend Screw M5 (Bus Type) 0.250 Q.C./ Solder Lug M6 Threaded Stud Push-In Stud Screw M4 w/upturned lugs and 30 bend Screw M4 (Bus Type) and 30 bend Printed Circuit Board Terminals Push-On 0.110 Tab (Q.C.) 9 LEGEND PLATE 0 No legend plate 1 A MOUNTING STYLEBARRIERS Standard Hex Nut no Standard Hex Nut (multipole only) yes 11 AGENCY APPROVAL C I 30 31 32 34 36 427 447 467 527 547 567 Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) Screw 10-32 w/upturned lugs Screw 10-32 (Bus Type) Screw 8-32 w/upturned lugs and 30 bend Screw 8-32 (Bus Type) and 30 bend Screw 10-32 w/upturned lugs and 30 bend Screw 10-32 (Bus Type) and 30 bend Screw M5 w/upturned lugs Screw M4 w/upturned lugs Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil 7 CURRENT RATING (AMPERES) CODE 1 0 1 8 Terminal UL Recognized & CSA Accepted UL Recognized, CSA Accepted, UL1500 Ignition Protected Notes: 1 Actuator Code M: Handle location as viewed from front of panel: 2 pole - right pole 3 pole - center pole 2 Switch Only circuits, rated up to 50 amps and 3 poles. Only available when tied to a protected pole. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 4 Consult factory for available Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 5 Auxiliary Switch available on Series Trip & Switch Only circuits, limited to 30 amps. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 8 UL Recognition and CSA Certification available on one and two pole breakers. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, B, F, G, H, M and Q. 10 Terminal Code 1: UL Recognition and CSA Certification up to 30 amps, but not recommended over 20 amps. 11 Terminal Code L : available up to 30A. 12 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50 amps, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with Circuit Codes A, B and C. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 16 | A-Series Sealed Toggle - Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance .020 [.51] unless otherwise specified. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com A-Series Rocker UL Recognized - Ordering Scheme | 17 A F 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 24 5 Aux/Alarm Switch 2 ACTUATOR1 Push-To-Reset , Single color R Vertical legend U Horizontal legend V No legend Two Color Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend E Indicate ON, no legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend H Indicate OFF, no legend Push-To-Reset, Visi-Rocker N Indicate OFF, vertical legend O Indicate OFF, horizontal legend P Indicate OFF, no legend Single color J Vertical legend K Horizontal legend L No legend 3 POLES 2 One B C 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 095 210 215 220 3 Two F4 G4 H4,5 Switch Only (No Coil) Series Trip (Current) Series Trip (Voltage) Shunt Trip (Current) Shunt Trip (Voltage) K4,5 Three Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil 5 w/o Aux Switch S.P.D.T., 0.093 Q.C. Term. S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) DC 50/60Hz, Switch Only DC Instantaneous DC Ultra Short DC Short DC Medium DC Long 50/60Hz Instantaneous 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 50/60Hz Long AMPERES 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.060 0.065 0.070 0.075 0.080 0.085 0.090 0.095 0.100 0.150 0.200 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 410 512 415 517 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 1.250 1.500 1.750 S.P.S.T., 0.093 Q.C. Term. (Gold Contacts) 6 S.P.S.T., 0.139 Solder Lug 7 S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) 8 S.P.S.T., 0.187 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. 30 31 32 34 36 429 449 469 529 549 569 DC, 50/60Hz Instantaneous DC, 50/60Hz Ultra Short DC, 50/60Hz Short DC, 50/60Hz Medium DC, 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush 420 522 527 430 435 440 445 450 455 460 465 470 475 480 485 490 495 610 710 2.000 2.250 2.750 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 611 711 612 712 613 614 615 616 617 618 620 622 624 625 630 63510 64010 64510 65010 J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC J65 65 AC K20 120 AC L40 240 AC OR VOLTAGE COIL (NORMAL RATED VOLTAGE)8 A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) Screw 10-32 w/upturned lugs Screw 10-32 (Bus Type) Screw 8-32 w/upturned lugs and 30 bend Screw 8-32 (Bus Type) and 30 bend Screw 10-32 w/upturned lugs and 30 bend Screw 10-32 (Bus Type) and 30 bend Screw M5 w/upturned lugs Screw M4 w/upturned lugs Actuator or Visi-Color12 White Black Red Green Blue Yellow Gray Orange 7 CURRENT RATING (AMPERES) CODE 9 Actuator Color 10 Mounting/ Barriers E13 F G H13 L14 M13 P15 Q16 R S17 T D 11 Agency Approval Screw M4 (Bus Type) Screw M5 w/upturned lugs and 30 bend Screw M5 (Bus Type) and 30 bend Screw M5 (Bus Type) 0.250 Q.C./ Solder Lug M6 Threaded Stud Printed Circuit BoardTerminals Push-In Stud Screw M4 w/upturned lugs and 30 bend Push-On 0.110 Tab (Q.C.) Screw M4 (Bus Type) and 30 bend 9 ACTUATOR COLOR & LEGEND 6 FREQUENCY & DELAY 03 10 11 12 14 16 20 21 22 24 26 7 9 5 AUXILIARY/ALARM SWITCH6,7 0 1 2 3 4 112 2 313 4 513 6 8 4 CIRCUIT A3 B C D4 E4 2 3 1 8 Terminal 7 Current Rating 8 TERMINAL11 1 SERIES A 1 630 6 Frequency & Delay 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 I-O A C F H K M P R Marking: ON-OFF Dual12 B 1 D 2 G 3 J 4 L 5 N 6 Q 7 S 8 Marking Color Single Color Visi-Rocker Black White White n/a White Red White Green White Blue Black Yellow Black Gray Black Orange 10 MOUNTING/BARRIERS20 1 A 2 B 3 C 4 D 8 H 9 J STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole BARRIERS 6-32 x 0.195 inches no 6-32 X 0.195 inches (multi-pole units only) yes ISO M3 x 5mm no ISO M3 x 5mm (multi-pole units only) yes ROCKERGUARD & PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 6-32 x 0.195 inches no 6-32 x 0.195 inches (multi-pole units only) yes ISO M3 x 5mm no ISO M3 x 5mm (multi-pole units only) yes FRONT PANEL SNAP-IN BRACKET, 0.744" wide bezel without Rockerguard (single pole units only) no with Rockerguard (single pole units only) no FRONT PANEL SNAP-IN BRACKET, 0.96" wide bezel without Rockerguard (single pole units only) no with Rockerguard (single pole units only) no 11 AGENCY APPROVAL C D E I UL Recognized & CSA Accepted VDE Certified, UL Recognized & CSA Accepted TUV Certified, UL Recognized & CSA Accepted UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 3 Switch Only circuits, rated up to 50 amps & 3 poles, are available only when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 4 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 5 Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 7 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 9 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 10 Series Trip current ratings: VDE Certification available with single pole breakers with DC Delay only. UL Recognition & CSA Accepted available in one and two pole breakers. 11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 12 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA Accepted up to 30 amps, but not recommended over 20 amps. 13 Terminal Codes 3, 5 E & H (Bus Type) with VDE, are supplied with Lock Washers; Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used. 14 VDE Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps. 15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL Recognition and CSA Accepted, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Certification with Circuit Codes A, B and C. 16 Terminal Code Q not available with VDE. 17 Terminal Code S used on voltage coil circuit constructions only. 18 Color shown is visi and legend with remainder of rocker black. 19 Dual = ON-OFF/I-O legend with actuator. None = no legend on actuator 20 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R, & U. Legend on Push-to-reset bezel/shroud matches Visi-color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through L. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 18 | A-Series Flat Rocker UL Recognized - Ordering Scheme A 1 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 24 5 Aux/Alarm Switch 112 2 313 4 513 6 2 ACTUATOR1 Two Color Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single color 3 Vertical legend 4 Horizontal legend Push-To-Reset, Visi-Rocker 5 Indicate OFF, vertical legend 6 Indicate OFF, horizontal legend Push-To-Reset , Single color 7 Vertical legend 8 Horizontal legend 7 8 9 B C 2 One F4 G4 H4,5 Switch Only (No Coil) Series Trip (Current) Series Trip (Voltage) Shunt Trip (Current) Shunt Trip (Voltage) K4,5 5 AUXILIARY/ALARM SWITCH6,7 5 w/o Aux Switch S.P.D.T., 0.093 Q.C. Term. S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 03 106 11 12 14 16 206 21 22 24 26 3 Two 4 CIRCUIT 0 1 2 3 4 DC 50/60Hz, Switch Only DC Instantaneous DC Ultra Short DC Short DC Medium DC Long 50/60Hz Instantaneous 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 50/60Hz Long 6 7 8 9 30 31 32 34 36 429 449 469 529 549 56 Three Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil S.P.S.T., 0.093 Q.C. Term. (Gold Contacts) S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. DC, 50/60Hz Instantaneous DC, 50/60Hz Ultra Short DC, 50/60Hz Short DC, 50/60Hz Medium DC, 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) CODE 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 095 210 215 220 AMPERES 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.060 0.065 0.070 0.075 0.080 0.085 0.090 0.095 0.100 0.150 0.200 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 410 512 415 517 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 1.250 1.500 1.750 420 522 527 430 435 440 445 450 455 460 465 470 475 480 485 490 495 610 710 2.000 2.250 2.750 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 611 711 612 712 613 614 615 616 617 618 620 622 624 625 630 63510 64010 64510 65010 J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC J65 65 AC K20 120 AC L40 240 AC OR VOLTAGE COIL (NORMAL RATED VOLTAGE)8 A06 6 DC A12 12 DC A18 18 DC A24 24 DC 9 Actuator Color Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) Screw 10-32 w/upturned lugs Screw 10-32 (Bus Type) Screw 8-32 w/upturned lugs and 30 bend Screw 8-32 (Bus Type) and 30 bend Screw 10-32 w/upturned lugs and 30 bend Screw 10-32 (Bus Type) and 30 bend Screw M5 w/upturned lugs Screw M4 w/upturned lugs 10 Mounting/ Barriers E13 F G H13 L14 M13 P15 Q R S16 T E 11 Agency Approval Screw M4 (Bus Type) Screw M5 w/upturned lugs and 30 bend Screw M5 (Bus Type) and 30 bend Screw M5 (Bus Type) 0.250 Q.C./ Solder Lug M6 Threaded Stud Printed Circuit Board Terminals Push-In Stud Screw M4 w/upturned lugs and 30 bend Push-On 0.110 Tab (Q.C.) Screw M4 (Bus Type) and 30 bend 9 ACTUATOR COLOR & LEGEND 3 POLES2 A3 B C D4 E4 2 3 1 8 Terminal 7 Current Rating 8 TERMINAL11 1 SERIES A 1 630 6 Frequency & Delay A32 32 DC A48 48 DC A65 65 DC J06 6 AC 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 Actuator or Visi-Color17 White Black Red Green Blue Yellow Gray Orange I-O A C F H K M P R Marking: ON-OFF Dual17 B 1 D 2 G 3 J 4 L 5 N 6 Q 7 S 8 Marking Color Single Color Visi-Rocker Black White White n/a White Red White Green White Blue Black Yellow Black Gray Black Orange 10 MOUNTING/BARRIERS18 1 A 2 B 5 E 6 F 3 C 4 D STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole FLAT ROCKER ACTUATOR 6-32 x 0.195 inches 6-32 X 0.195 inches (multi-pole units only) ISO M3 x 5mm ISO M3 x 5mm (multi-pole units only) RECESSED OFF SIDE ROCKER ACTUATOR19 6-32 x 0.195 inches 6-32 x 0.195 inches (multi-pole units only) ISO M3 x 5mm ISO M3 x 5mm (multi-pole units only) PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 6-32 x 0.195 inches 6-32 x 0.195 inches (multi-pole units only) ISO M3 x 5mm ISO M3 x 5mm (multi-pole units only) BARRIERS no yes no yes no yes no yes no yes no yes 11 AGENCY APPROVAL C E I UL Recognized & CSA Accepted TUV Certified, UL Recognized & CSA Accepted UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 3 Switch Only circuits, rated up to 50 amps & 3 poles. Only available when tied to a protected pole. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 4 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 5 Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 7 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 9 Available with Circuit Codes B & D only. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 10 UL Recognition, CSA Acceptance & TUV Certification available in one and two pole breakers. 11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 12 Terminal Code 1: Available up to 30 amps, but not recommended over 20 amps. 13 Terminal Codes 3, 5 E & H (Bus Type) with TUV, are supplied with Lock Washers; Terminal Code M (M6 Threaded Stud) with TUV is supplied with Lock and Flat Washers. These breakers are only TUV Certified when the washers are used. 14 TUV Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps. 15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50 amps with UL Recognition, CSA Accepted & TUV Certification, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Accepted with Circuit Codes A, B and C. 16 Terminal Code S used on voltage coil circuit constructions only. 17 Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend. 18 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes 5 & 6. 19 Recessed "off-side" available with actuator codes 1, 2, 3 & 4. Legends on rocker are available in ink stamping only. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com A-Series Flat Rocker UL 489A - Ordering Scheme | 19 A 1 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 6 Frequency & Delay 1 SERIES A 17 2 38 4 58 6 Two Color Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single color 3 Vertical legend 4 Horizontal legend Push-To-Reset, Visi-Rocker 5 Indicate OFF, vertical legend 6 Indicate OFF, horizontal legend Push-To-Reset , Single color 7 Vertical legend 8 Horizontal legend 3 POLES2 2 One 7 8 3 Two w/o Aux Switch S.P.D.T., 0.093 Q.C. Term. S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug 6 FREQUENCY & DELAY 11 12 14 16 Three 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 DC Ultra Short DC Short DC Medium DC Long AMPERES 0.100 0.150 0.200 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 10 Mounting/ Barriers 285 290 295 410 512 415 517 420 522 527 430 435 440 445 450 0.850 0.900 0.950 1.000 1.250 1.500 1.750 2.000 2.250 2.750 3.000 3.500 4.000 4.500 5.000 9 B F G H8 M8 P9 Q10 11 Max. Appl. Rating 12 Agency Approval Screw 10-32 (Bus Type) and 30 bend Screw M5 w/upturned lugs Screw M5 w/upturned lugs and 30 bend Screw M5 (Bus Type) and 30 bend Screw M5 (Bus Type) M6 Threaded Stud Printed Circuit Board Terminals Push-In Stud Marking: ON-OFF Dual11 B 1 D 2 G 3 J 4 L 5 N 6 Q 7 S 8 Marking Color Single Color Visi-Rocker Black White White n/a White Red White Green White Blue Black Yellow Black Gray Black Orange 10 MOUNTING/BARRIERS12 7 8 9 S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 52 54 56 DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) CODE 9 Actuator Color Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) Screw 10-32 w/upturned lugs Screw 10-32 (Bus Type) Screw 8-32 w/upturned lugs and 30 bend Screw 8-32 (Bus Type) and 30 bend Screw 10-32 w/upturned lugs and 30 bend Actuator or Visi-Color11 White Black Red Green Blue Yellow Gray Orange Series Trip (Current) 5 AUXILIARY/ALARM SWITCH3 0 1 2 3 8 Terminal M T 9 ACTUATOR COLOR & LEGEND 4 CIRCUIT B 7 Current Rating 2 3 1 8 TERMINAL5 2 ACTUATOR1 1 630 455 460 465 470 475 480 485 490 495 610 710 611 711 612 712 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 11.000 11.500 12.000 12.500 613 614 615 616 617 618 620 622 624 625 630 6354 6404 6454 6504 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 1 A 2 B 5 E 6 F 3 C 4 D STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole FLAT ROCKER ACTUATOR 6-32 x 0.195 inches 6-32 X 0.195 inches (multi-pole units only) ISO M3 x 5mm ISO M3 x 5mm (multi-pole units only) RECESSED OFF SIDE ROCKER ACTUATOR 13 6-32 x 0.195 inches 6-32 x 0.195 inches (multi-pole units only) ISO M3 x 5mm ISO M3 x 5mm (multi-pole units only) PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 6-32 x 0.195 inches 6-32 x 0.195 inches (multi-pole units only) ISO M3 x 5mm ISO M3 x 5mm (multi-pole units only) BARRIERS no yes no yes no yes no yes no yes no yes 11 MAXIMUM APPLICATION RATING M 80 DC 12 AGENCY APPROVAL T J UL489A LISTED UL489A LISTED, TUV CERTIFIED Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 3 Auxiliary Switch breakers with Series Trip circuits: 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 6 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps. 7 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used. 8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend. 11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through K 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 20 | A-Series Rocker - Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance .020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuit. 4 Circuits shown for >30 amps / VDE. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com A-Series Rocker - Form & Fit Drawings | 21 Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate OFF is opposite of indicate ON. 2 For pole orientation with horizontal legend, rotate front view clockwise 90. 3 All dimensions are in inches [millimeters]. 4 Tolerance 0.20 [.51] unless otherwise specified. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 22 | A-Series Rocker Snap-In Bracket - Form & Fit Drawings Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal 2 For pole orientation with horizontal legend, rotate front view clockwise 90. Orientation on indicate "OFF" is opposite of indicate "ON" 3 Recommended panel thickness: .04 0 [1.02] to .100 [2.54] 4 All dimensions are in Inches [millimeters]. 5 Tolerance .020 [.51] unless otherwise specified. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com A-Series Flat Rocker - Form & Fit Drawings | 23 Notes: 1 All dimensions are in inches [millimeters]. 2 For pole orientation with horizontal legend, rotate front view clockwise 90. 3 Tolerance 0.20 [.51] unless otherwise specified. 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 24 | A-Series PC Terminal Diagrams Notes: 1 Drawing illustrates A-Series with VDE certification. 2 All dimensions are in inches [millimeters]. 3 Tolerance 0.20 [.51] unless otherwise specified REV_CB_A_02_2014 60 Johnson Avenue * Plainville, CT 06062 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com