Q45BW13 Series
page 7
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Q45BW13 Series Specifications
Supply Voltage and Current Universal voltage: 24 to 250V ac, 50/60 Hz or 12 to 250V dc (1.5 watts maximum)
Supply Protection Circuitry Protected against transient voltages. DC hookup is without regard to polarity.
Output Configuration All models except emitters: Optically isolated SPST solid-state switch
Output Rating 250V ac, 250V dc, 300 mA
Output saturation voltage: 3V at 300 mA, 2V at 15 mA
Off-state leakage current: <50 microamps
Inrush current: 1 amp for 20 milliseconds, non-repetitive
Output Protection Circuitry Protected against false pulse on power-up
Output Response Time Opposed mode: 2 milliseconds on, 1 millisecond off
All other sensing modes: 2 milliseconds on/off
(NOTE: 100 millisecond delay on power-up. Output is non-conducting during this time.)
Repeatability Opposed mode: 0.25 milliseconds
All other sensing modes: 0.5 milliseconds
Response time and repeatability specifications are independent of signal strength.
Adjustments Light/Dark Operate select switch; and multi-turn Sensitivity control on top of sensor beneath a transparent
o-ring-sealed Lexan®cover, allows precise sensitivity setting (turn clockwise to increase gain). Optional logic
and logic/display modules have adjustable timing functions (see page 10).
Indicators Indicator LEDs are clearly visible beneath a raised transparent Lexan®dome on top of the sensor.
Power (green) LED lights whenever 24 to 250V ac, or 12 to 250V dc power is applied
Signal (red) AID™ System LED lights whenever the sensor sees its modulated light source, and pulses at a
rate proportional to the strength of the received light signal
Load (yellow) LED lights whenever the output relay is energized
Optional 7-element LED signal strength display module
Construction Molded reinforced thermoplastic polyester housing, o-ring-sealed transparent Lexan®cover, molded acrylic
lenses, and stainless steel hardware. Q45s are designed to withstand 1200 psi washdown. The base of
cabled models has a 1/2" NPS integral internal conduit thread.
Environmental Rating NEMA 6P, IEC IP67
Connections PVC-jacketed 2 m (6.5') or 9 m (30') unterminated cables, or Mini-style quick-disconnect (QD) fittings are
available (“Q”- suffix models). QD cables are ordered separately. See page 10.
Operating Conditions Temperature: -25° to +55° C (-13° to +131°F)
Maximum relative humidity: 90% at 50°C (non-condensing)
Application Notes Optional output timing modules are available. See page 10 for more information.
Output is not short-circuit protected. Exercise care when making wiring connections.
Lexan®is a registered trademark of General Electric Co.
Certifications