http://www.tracopower.com Page 1 of 3
DC/DC Converters
TES 2N Series, 2 Watt
Features
◆ Low profile SMD-package
◆ Wide 2:1 input voltage range
◆ I/O isolation 1500 VDC
◆ Input filter meets EN55022, class A
◆ Operating temperature range
–40°C to +85°C
◆ Short-circuit protection
◆ Qualified for leadfree reflow solder
process according IPC J-STD-020D.1
◆ Available in tape and reel package
◆ Bears washing process
◆ 3-year product warranty
Ordercode Input voltage range Output voltage Output current max. Efficiency typ.
TES 2N-0510 3.3 VDC 500 mA 70 %
TES 2N-0511 5 VDC 400 mA 73 %
TES 2N-0512 4.5 – 9.0 VDC 12VDC 165 mA 75 %
TES 2N-0513 (nominal 5 VDC) 15 VDC 135 mA 73 %
TES 2N-0521 ± 5 VDC ±200 mA 64 %
TES 2N-0522 ±12 VDC ±85 mA 69 %
TES 2N-0523 ±15 VDC ±65 mA 71 %
TES 2N-1210 3.3 VDC 500 mA 73 %
TES 2N-1211 5 VDC 400 mA 77 %
TES 2N-1212 9 – 18 VDC 12 VDC 165 mA 80 %
TES 2N-1213 (nominal 12 VDC) 15 VDC 135 mA 80 %
TES 2N-1221 ±5 VDC ±200 mA 73 %
TES 2N-1222 ±12 VDC ±85 mA 78 %
TES 2N-1223 ±15 VDC ±65 mA 78 %
TES 2N-2410 3.3 VDC 500 mA 72 %
TES 2N-2411 5 VDC 400 mA 77 %
TES 2N-2412 18 – 36 VDC 12 VDC 165 mA 80 %
TES 2N-2413 (nominal 24 VDC) 15 VDC 135 mA 81 %
TES 2N-2421 ±5 VDC ±200 mA 74 %
TES 2N-2422 ±12 VDC ±85 mA 78 %
TES 2N-2423 ±15 VDC ±65 mA 80 %
TES 2N-4810 3.3 VDC 500 mA 71 %
TES 2N-4811 5 VDC 400 mA 73 %
TES 2N-4812 36 – 75 VDC 12 VDC 165 mA 79 %
TES 2N-4813 (nominal 48 VDC) 15 VDC 135 mA 79 %
TES 2N-4821 ± 5 VDC ±200 mA 71 %
TES 2N-4822 ±12 VDC ±85 mA 77 %
TES 2N-4823 ±15 VDC ±65 mA 77 %
Models
The TES-2N series is a family of high performance 2W DC/DC converter modules
featuring wide 2:1 input voltage ranges. The 28 models come in a low profile SMD
package which requires just 3 cm2 space on the PCB. A high efficiency allows an
operating temperature range of –40°C to +85°C. A built-in EMI input filter complies
with EN 55022, class A. Typical applications for these converters are battery ope-
rated equipment, instrumentation, communication and industrial electronics, every-
where where isolated, tightly regulated voltages are required.
UL 60950-
Scheme