3-Volt Advanced+ Boot Block Flash
Memory
28F800C3, 28F160C3, 28F320C3, 28F640C3 (x16)
Datasheet
Product Features
The 3-Volt Advanced+ Book Block Flash memory, manufactured on Intel’s latest 0.13 µmand
0.18 µm technologies, represents a feature-rich solution for low-power applications. 3-Volt
Advanced+ Boot Block Flash memory devices incorporate low-voltage capability (2.7 V read,
program, and erase) with high-speed, low-power operation. Flexible block locking allows any
block to be independently locked or unlocked. Add to this the Intel®Flash Data Integrator (IFDI)
software and you have a cost-effecive, flexible, monolithic code plus data storage solution. Intel®
3-Volt Advanced+ Boot Block products will be available in 48-lead TSOP, 48-ball CSP, and 64-
ball Easy BGA packages. Additional information on this product family can be obtained by
accessing the Intel®Flash website: http://www.intel.com/design/flash.
Flexible SmartVoltage Technology
2.7 V–3.6 V Read/Program/Erase
12 V for Fast Production Programming
1.65 V–2.5 V or 2.7 V–3.6 V I/O Option
Reduces Overall System Power
High Performance
2.7 V–3.6 V: 70 ns Max Access Time
Optimized Architecture for Code Plus Data
Storage
Eight 4-Kword Blocks, Top or Bottom
Locations
Up to One Hundred-Twenty-Seven 32-
Kword Blocks
Fast Program Suspend Capability
Fast Erase Suspend Capability
Flexible Block Locking
Lock/Unlock Any Block
Full Protection on Power-Up
WP# Pin for Hardware Block Protection
—VPP = GND Option
—VCC Lockout Voltage
Low Power Consumption
9 mA Typical Read Power
7 µA Typical Standby Power with
Automatic Power Savings Feature
12 V Fast Production Program
Extended Temperature Operation
—–40 °C to +85 °C
128-bit Protection Register
64-bit Unique Device Identifier
64-bit User Programmable OTP Cells
Extended Cycling Capability
Minimum 100,000 Block Erase Cycles
Supports Intel®Flash Data Integrator
Software
Flash Memory Manager
System Interrupt Manager
Supports Parameter Storage, Streaming
Data (e.g., voice)
Automated Word/Byte Program and Block
Erase
Command User Interface
Status Registers
Cross-Compatible Command Support
Intel Basic Command Set
Common Flash Interface
Standard Surface Mount Packaging
48-Ball CSP Packages
64-Ball Easy BGA Packages
48-Lead TSOP Package
ETOX™ VIII (0.13 µm)Flash Technology
16-, 32-Mbit
ETOX™ VII (0.18 µm)Flash Technology
16-, 32-, 64-Mbit
ETOX™ VI (0.25 µm) Flash Technology
8-, 16- and 32-Mbit
Order Number: 290645-014
April 2002
Notice: This specification is subject to change without notice. Verify with your local Intel sales
office that you have the latest datasheet before finalizing a design.
2Datasheet
Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual
property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability
whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to
fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not
intended for use in medical, life saving, or life sustaining applications.
Intel may make changes to specifications and product descriptions at any time, without notice.
Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined." Intel reserves these for
future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them.
The 28F800C3, 28F160C3, 28F320C3, 28F640C3 may contain design defects or errors known as errata which may cause the product to deviate from
published specifications. Current characterized errata are available on request.
MPEG is an international standard for video compression/decompression promoted by ISO. Implementations of MPEG CODECs, or MPEG enabled
platforms may require licenses from various entities, including Intel Corporation.
Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order.
Copies of documents which have an ordering number and are referenced in this document, or other Intel literature may be obtained by calling 1-800-
548-4725 or by visiting Intel's website at http://www.intel.com.
Copyright © Intel Corporation, 2002
*Third-party brands and names are the property of their respective owners.
Datasheet 3
Contents
Contents
1.0 Introduction ...............................................................................................................................7
1.1 Document Purpose ...............................................................................................................7
1.2 Nomenclature .......................................................................................................................7
1.3 Conventions..........................................................................................................................7
2.0 Device Description..................................................................................................................8
2.1 Product Overview .................................................................................................................8
2.2 Product Overview .................................................................................................................9
3.0 Product Description .............................................................................................................10
3.1 Package Pinouts.................................................................................................................11
3.2 Block Organization..............................................................................................................17
3.2.1 Parameter Blocks ..................................................................................................17
3.2.2 Main Blocks ...........................................................................................................17
4.0 Principles of Operation .......................................................................................................17
4.1 Bus Operation.....................................................................................................................17
4.1.1 Read ......................................................................................................................17
4.1.2 Output Disable .......................................................................................................18
4.1.3 Standby..................................................................................................................18
4.1.4 Reset .....................................................................................................................18
4.1.5 Write ......................................................................................................................19
4.2 Modes of Operation ............................................................................................................19
4.2.1 Read Array.............................................................................................................19
4.2.2 Read Configuration ................................................................................................20
4.2.3 Read Status Register.............................................................................................20
4.2.3.1 Clearing the Status Register ..................................................................21
4.2.4 Read Query ...........................................................................................................21
4.2.5 Program Mode .......................................................................................................21
4.2.5.1 Suspending and Resuming Program .....................................................21
4.2.6 Erase Mode ...........................................................................................................22
4.2.6.1 Suspending and Resuming Erase .........................................................22
4.3 Flexible Block Locking ........................................................................................................25
4.3.1 Locking Operation..................................................................................................26
4.3.1.1 Locked State ..........................................................................................26
4.3.2 Unlocked State ......................................................................................................26
4.3.3 Lock-Down State ...................................................................................................26
4.3.4 Reading Block-Lock Status....................................................................................27
4.3.5 Locking Operations during Erase Suspend ...........................................................27
4.3.6 Status Register Error Checking .............................................................................27
4.4 128-Bit Protection Register.................................................................................................28
4.4.1 Reading the Protection Register............................................................................28
4.4.2 Programming the Protection Register....................................................................29
4.4.3 Locking the Protection Register .............................................................................29
4.5 VPP Program and Erase Voltages ......................................................................................29
4.5.1 Improved 12-Volt Production Programming...........................................................29
4.5.2 VPP £ VPPLK for Complete Protection .................................................................30
Contents
4Datasheet
4.6 Power Consumption ........................................................................................................... 30
4.6.1 Active Power (Program/Erase/Read)..................................................................... 31
4.6.2 Automatic Power Savings (APS) ........................................................................... 31
4.6.3 Standby Power ...................................................................................................... 31
4.6.4 Deep Power-Down Mode....................................................................................... 31
4.7 Power and Reset Considerations ....................................................................................... 31
4.7.1 Power-Up/Down Characteristics............................................................................ 31
4.7.2 RP# Connected to System Reset.......................................................................... 32
4.7.3 VCC, VPP and RP# Transitions ............................................................................ 32
4.8 Power Supply Decoupling................................................................................................... 32
5.0 Electrical Specifications..................................................................................................... 33
5.1 Absolute Maximum Ratings ................................................................................................ 33
5.2 Operating Conditions ..........................................................................................................34
5.3 Capacitance........................................................................................................................ 34
5.4 DC Characteristics.............................................................................................................. 35
4.5 AC Characteristics—Read Operations ............................................................................... 38
4.6 AC Characteristics—Write Operations ............................................................................... 43
4.7 Erase and Program Timings............................................................................................... 47
4.8 Reset Operations................................................................................................................ 49
Appendix A WSM Current/Next States, Sheet 1 of 2 ...................................................50
Appendix B Program/Erase Flowcharts .........................................................................52
Appendix C Common Flash Interface Query Structure..............................................58
Appendix D Architecture Block Diagram .......................................................................65
Appendix E Word-Wide Memory Map Diagrams ..........................................................66
Appendix F Device ID Table...............................................................................................70
Appendix G Protection Register Addressing................................................................71
Appendix H VF Pitch BGA Package Drawing and Dimensions................................72
Appendix I Easy BGA Package Drawing & Dimensions ............................................73
Appendix J Additional Information ..................................................................................74
Appendix K Ordering Information ....................................................................................75
Datasheet 5
Contents
Revision History
Date of
Revision Version Description
05/12/98 -001 Original version
07/21/98 -002
48-Lead TSOP package diagram change
µBGA package diagrams change
32-Mbit ordering information change (Section 6)
CFI Query Structure Output Table Change (Table C2)
CFI Primary-Vendor Specific Extended Query Table Change for Optional
Features and Command Support change (Table C8)
Protection Register Address Change
IPPD test conditions clarification (Section 4.3)
µBGA package top side mark information clarification (Section 6)
10/03/98 -003
Byte-Wide Protection Register Address change
VIH Specification change (Section 4.3)
VIL Maximum Specification change (Section 4.3)
ICCS test conditions clarification (Section 4.3)
Added Command Sequence Error Note (Table 7)
Datasheet renamed from 3 Volt Advanced Boot Block, 8-, 16-, 32-Mbit Flash
Memory Family.
12/04/98 -004 Added tBHWH/tBHEH and tQVBL (Section 4.6)
Programming the Protection Register clarification (Section 3.4.2)
12/31/98 -005 Removed all references to x8 configurations
02/24/99 -006 Removed reference to 40-Lead TSOP from front page
06/10/99 -007
AddedEasyBGApackage(Section1.2)
Removed 1.8 V I/O references
Locking Operations Flowchart changed (Appendix B)
Added tWHGL (Section 4.6)
CFI Primary Vendor-Specific Extended Query changed (Appendix C)
03/20/00 -008 Max ICCD changed to 25 µA
Table 10, added note indicating VCCMax = 3.3 V for 32-Mbit device
04/24/00 -009 Added specifications for 0.18 micron product offerings throughout document
Added 64-Mbit density
10/12/00 -010
Changed references of 32Mbit 80ns devices to 70ns devices to reflect the
faster product offering.
Changed VccMax=3.3V reference to indicate that the affected product is the
0.25µm 32Mbit device.
Minor text edits throughout document.
7/20/01 -011
Added 1.8v I/O operation documentation where applicable
Added TSOP PCN ‘Pin-1’ indicator information
Changed references in 8 x 8 BGA pinout diagrams from ‘GND’ to ‘Vssq’
Added ‘Vssq’ to Pin Descriptions Information
Removed 0.4 µm references in DC characteristics table
Corrected 64Mb package Ordering Information from 48-uBGA to 48-VFBGA
Corrected ‘bottom’ boot block sizes to on 8Mb device to 8 x 4KWords
Minor text edits throughout document
Contents
6Datasheet
10/02/01 -012 Added specifications for 0.13 micron product offerings throughout document
2/05/02 -013
Corrected Iccw / Ippw / Icces /Ippes values.
Added mechanicals for 16Mb and 64Mb
Minor text edits throughout document.
4/05/02 -014
Updated 64Mb product offerings.
Updated 16Mb product offerings.
Revised and corrected DC Characteristics Table.
Added mechanicals for Easy BGA.
Minor text edits throughout document.
Date of
Revision Version Description
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 7
1.0 Introduction
1.1 Document Purpose
This document contains the specifications for the 3-Volt Advanced+ Boot Block Flash Memory
family. These flash memories add features, such as instant block locking and a protection register,
that can be used to enhance the security of systems.
1.2 Nomenclature
0x Hexadecimal prefix
0b Binary prefix
k (noun) 1 thousand
M (noun) 1 million
Nibble 4 bits
Byte 8 bits
Word 16 bits
Dword Double word = 32 bits
Kword 1024 words
Mword 1,048,576 words
Kb 1024 bits
KB 1024 bytes
Mb 1,048,576 bits
MB 1,048,576 bytes
APS Automatic Power Savings
CUI Command User Interface
OTP One Time Programmable
PR Protection Register
PRD Protection Register Data
PLR Protection Lock Register
RFU Reserved for Future Use
SCSP Stacked Chip Scale Package
SR Status Register
SRD Status Register Data
WSM Write State Machine
XSR eXtended Status Register
MLC Multi-Level Cell
1.3 Conventions
Group Membership Brackets: Square brackets will be used to designate group membership or to
define a group of signals with similar function (I.E. A[21:1], SR[4,1] )
VPEN vs. VPEN:When the reference is signal or package connection name, the notation will be
VPEN (specifically VPEN[2:1] or VPEN2 and VPEN1). When the reference is timing or level, the
notation will be VPEN only.
28F800C3, 28F160C3, 28F320C3, 28F640C3
8Datasheet
[opt. - multi-die use]Device: This term is used interchangeably throughout this document to denote
either the particular die, or the combination of the two die.
[opt. - multi-die use]Status Register: Each die has its own status register (SR), read out on the
lower 8 bits of each die's data bus. SR[23:16], the valid status bits for die #2 (upper die) are read on
device outputs D[23:16]; bits SR[31:24] are RFU. SR[7:0], the valid status bits for die #1 (lower
die) are read on device outputs D[7:0]; bits SR[15:8] are RFU.
[opt. - multi-die use]CE#[2:1]: This method of referring to the two chip enable inputs will be used
in the document when considering them as a single entity. When considered singly, they will be
referenced as CE#1 (die #1 chip enable) and CE#2 (die #2 chip enable).
2.0 Device Description
This section provides an overview of the 3-Volt Advanced+ Boot Block Flash Memory features,
packaging information , signal names and device architecture
2.1 Product Overview
The 3-Volt Advanced+ Boot Block Flash Memory product lineis a high perfomance memory utilizes reliable
and proven ETOX™ technology This family of products features 1.65 V 2.5 V or 2.7 V–3.6 V I/Os and a
low VCC/VPP operating range of 2.7 V–3.6 V for Read, Program, and Erase operations. In addition, this fam-
ily is capable of fast programming at 12 V. The 3-Volt Advanced+ Boot Block flash memory features include
the following:
Zero-latency, flexible block locking
128-bit Protection Register
Simple system implementation for 12-V production programming with 2.7-V, in-field
programming
Ultra low-power operation at 2.7 V
VCCQ input of 1.65 V–2.5 V on all I/Os. See Figures 1 through 4 for pinout diagrams and
VCCQ location
Minimum 100,000 block erase cycles
Common Flash Interface for software query of device specs and features
Table 1. 3-Volt Advanced+ Boot Block Feature Summary (Sheet 1 of 2)
Feature 8 Mbit(1),16Mbit,32Mbit
(2) Reference
VCC Operating Voltage 2.7 V 3.6 V(3) Tab le 8
VPP Voltage Provides complete write protection with optional 12 V Fast Programming Tab l e 8
VCCQ I/O Voltage 1.65 V 2.5 V or 2.7 V 3.6 V
Bus Width 16-bit Tab l e 2
Speed (ns)
8 Mbit: 90, 110 @ 2.7 V and 80, 100 @ 3.0 V
16 Mbit: 70, 80, 90, 110 @ 2.7 V and 70, 80, 100 @ 3.0 V
32 Mbit: 70, 90, 100, 110 @ 2.7 V and 70, 90, 100 @ 3.0 V
64 Mbit: 80, 100 @ 2.7 V and 80, 100 @ 3.0 V
Section 5.4
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 9
2.2 Product Overview
Intel provides secure low voltage memory solutions with the Advanced Boot Block family of
products. A new block locking feature allows instant locking/unlocking of any block with zero
latency. A 128-bit protection register allows unique flash device identification.
Discrete supply pins provide single voltage read, program, and erase capability at 2.7 V, while also
allowing 12-V VPP for faster production programming. Improved 12 V, a new feature designed to
reduce external logic, simplifies board designs when combining 12-V production programming
with 2.7-V in-field programming.
The 3-Volt Advanced+ Boot Block flash memory products are available in x16 packages in the
following densities: (see Section A, Ordering Information” on page 50)
8-Mbit (8, 388, 608 bit) flash memories organized as 512 Kwords of 16 bits each
16-Mbit (16, 777, 216 bit) flash memories organized as 1024 Kwords of 16 bits each
32-Mbit (33, 554, 432 bit) flash memories organized as 2048 Kwords of 16 bits each
64-Mbit (67, 108, 864 bit) flash memories organized as 4096 Kwords of 16 bits each.
Eight 4-Kword parameter blocks are located at either the top (denoted by -T suffix) or the bottom
(-B suffix) of the address map in order to accommodate different microprocessor protocols for
kernel code location. The remaining memory is grouped into 64-Kbyte main blocks (see Appendix
E).
All blocks can be locked or unlocked instantly to provide complete protection for code or data (see
Section 4.3, Flexible Block Locking” on page 25 for details).
The Command User Interface (CUI) serves as the interface between the microprocessor or
microcontroller and the internal operation of the flash memory. The internal Write State Machine
(WSM) automatically executes the algorithms and timings necessary for Program and Erase
operations, including verification, thereby unburdening the microprocessor or microcontroller. The
status register indicates the status of the WSM by signifying block-erase or word program
completion and status.
Blocking (top or bottom)
8 x 4-Kword parameter
8-Mb: 15 x 32-Kword main
16-Mb: 31 x 32-Kword main
32-Mb: 63 x 32-Kword main
64-Mb: 127 x 32-Kword main
Appendix 3.2
Appendix E
Operating Temperature Extended: –40 °C to +85 °C Tabl e 8
Program/Erase Cycling 100,000 cycles Tabl e 8
Packages 48-Lead TSOP
48-Ball µBGA* CSP (1), 48-Ball VF BGA, Easy BGA Figure 1,2and3
Block Locking Flexible locking of any block with zero latency Section 4.3
Protection Register 64-bit unique device number, 64-bit user programmable Section 4.4
NOTES:
1. 8-Mbit density not available in µBGA* CSP.
2. See Specification Update for changes to 32-Mbit devices (order 297938).
3. VCCMax = 3.3 V on 0.25µm 32-Mbit devices.
Table 1. 3-Volt Advanced+ Boot Block Feature Summary (Sheet 2 of 2)
Feature 8 Mbit(1),16Mbit,32Mbit
(2) Reference
28F800C3, 28F160C3, 28F320C3, 28F640C3
10 Datasheet
Program and erase automation allows Program and Erase operations to be executed using an
industry-standard two-write command sequence to the CUI. Program operations are performed in
word increments. Erase operations erase all locations within a block simultaneously. Both Program
and Erase operations can be suspended by the system software in order to read from any other
block. In addition, data can be programmed to another block during an erase suspend.
The 3-Volt Advanced+ Boot Block flash memories offer two low-power savings features:
Automatic Power Savings (APS), and standby mode. The device automatically enters APS mode
following the completion of a read cycle. Standby mode is initiated when the system deselects the
device by driving CE# inactive. Combined, these two power-savings features significantly reduce
power consumption.
The device can be reset by lowering RP# to GND, which provides CPU memory reset
synchronization and additional protection against bus noise that may occur during system reset and
power-up/down sequences (see Section 4.5 and Section 4.6).
Refer to Section 5.4, “DC Characteristics” on page 35 for complete current and voltage
specifications. Refer to Section 4.5 and Section 4.6 for read and write performance specifications.
Section 4.7 shows program and erase times.
3.0 Product Description
This section provides device pin descriptions and package pinouts for the 3-Volt Advanced+ Boot
Block Flash Memory family, which is available in 48-lead TSOP (x16) and 48-ball µBGA and
Easy BGA packages (Figures 1, 2 and 3, respectively).
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 11
3.1 Package Pinouts
0645_02
Note: Lower densities will have NC on the upper address pins. For example, a 16-Mbit device will have
NC on Pins 9 and 10.
Figure 1. 48-Lead TSOP Package
Advanced+ Boot Block
48-Lead TSOP
12 mm x 20 mm
TOP VIEW
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
A
16
V
CCQ
GND
DQ
15
DQ
7
DQ
14
DQ
6
DQ
13
DQ
5
DQ
12
DQ
4
V
CC
DQ
11
DQ
3
DQ
10
DQ
2
DQ
9
DQ
1
DQ
8
DQ
0
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
A
15
A
14
A
13
A
12
A
11
A
10
A
9
A
8
A
21
A
20
WE#
RP#
V
PP
WP#
A
19
A
18
A
17
A
7
A
6
A
5
21
22
23
24
OE#
GND
CE#
A
0
28
27
26
25
A
4
A
3
A
2
A
1
32 M
16 M
64 M
28F800C3, 28F160C3, 28F320C3, 28F640C3
12 Datasheet
Note: The topside marking on 8 Mb, 16 Mb, and 32 Mb Advanced and Advanced + Boot Block 48L
TSOP products will convert to a white ink triangle as a Pin 1 indicator. Products without the white
triangle will continue to use a dimple as a Pin 1 indicator. There are no other changes in package
Figure 2. New Mark for Pin-1 indicator on 48-Lead 8Mb, 16Mb and 32Mb TSOP
Current Mark:
New Mark:
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 13
size, materials, functionality, customer handling, or manufactuability. Product will continue to
meet Intel stringent quality requirements.
Products Affected are Intel Ordering Codes:
48-Lead TSOP
Extended
32 Mbit
TE28F320C3TC70
TE28F320C3BC70
TE28F320C3TC90
TE28F320C3BC90
TE28F320C3TA100
TE28F320C3BA100
TE28F320C3TA110
TE28F320C3BA110
Extended
16 Mbit
TE28F160C3TC70
TE28F160C3BC70
TE28F160C3TC80
TE28F160C3BC80
TE28F160C3TA90
TE28F160C3BA90
TE28F160C3TA110
TE28F160C3BA110
Extended
8Mbit
TE28F800C3TA90
TE28F800C3BA90
TE28F800C3TA110
TE28F800C3BA110
28F800C3, 28F160C3, 28F320C3, 28F640C3
14 Datasheet
NOTE: Shaded connections indicate the upgrade address connections. Lower density devices will not have the
upper address solder balls. Routing is not recommended in this area. A19 is the upgrade address for the
16-Mbit device. A20 is the upgrade address for the 32-Mbit device. A21 is the upgrade address for the
64-Mbit device. 4-Mbit density not available in µBGA CSP.
Figure 3. 48-Ball µBGA* and 48-Ball Very Fine Pitch BGA Chip Size Package
(Top View, Ball Down)
13254768
A
B
C
D
E
F
A13
A14
A15
A16
VCCQ
A11
A10
A12
D14
D15
A8
WE#
A9
D5
D6
VPP
RP#
A21
D11
D12
WP#
A18
A20
D2
D3
A19
A17
A6
D8
D9
A7
A5
A3
CE#
D0
A4
A2
A1
A0
GND
GND D7 D13 D4 VCC D10 D1 OE#
16M
32M64M
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 15
16fast
NOTES:
1. A19 denotes 16 Mbit; A20 denotes 32 Mbit; A21 denotes 64 Mbit.
2. A22 indicates future density upgrade path to128 Mbit (not yet available).
Figure 4. 8 x 8 Easy BGA Package
1234567 8
A
B
C
D
E
F
G
H
Top View
-BallSide Bottom View - Ball Side
A1A6A18 VPP VCC GND A10 A15
A2A17 A19
(1) RP# DU A20
(1) A11 A14
A3A7WP# WE# DU A
21
(1) A12 A13
A4A5DU
DQ
8DQ
1DQ
9DQ
3DQ
12 DQ
6DU DU
CE# DQ
0DQ
10 DQ
11 DQ
5DQ
14 DU DU
A0VSSQ DQ
2DQ
4DQ
13 DQ
15 VSSQ A16
A22
(2) OE# VCCQ VCC VSSQ DQ
7VCCQ DU
DU DU DU A8A9
8 7 6 5 4 3 2 1
A
B
C
D
E
F
G
H
A15 A10 GND VCC VPP A18 A6A1
A14 A11 A20
(1) DU RP# A19
(1) A17 A2
A13 A12 A21
(1) DU WE# WP# A7A3
A9A8DU
DU DU DQ
6DQ
12 DQ
3DQ
9DQ
1DQ
8
DU DU DQ
14 DQ
5DQ
11 DQ
10 DQ
0CE#
A16 VSSQ D15 D13 DQ
4DQ
2VSSQ A0
DU VCCQ D7VSSQ VCC VCCQ OE# A22
(2)
DU DU DU A5A4
28F800C3, 28F160C3, 28F320C3, 28F640C3
16 Datasheet
Table 2. 3-Volt Advanced+ Boot Block Pin Descriptions
Symbol Type Name and Function
A0–A21 INPUT ADDRESS INPUTS: Memory addresses are internally latched during a program or erase cycle.
8-Mbit: A[0-18], 16-Mbit: A[0-19], 32-Mbit: A[0-20], 64-Mbit: A[0-21]
DQ0–DQ7
INPUT/
OUTPUT
DATA INPUTS/OUTPUTS: Inputs array data on the second CE# and WE# cycle during a Program
command. Inputs commands to the Command User Interface when CE# and WE# are active.
Data is internally latched. Outputs array, configuration and status register data. The data pins float
to tri-state when the chip is de-selected or the outputs are disabled.
DQ8–DQ15
INPUT/
OUTPUT
DATA INPUTS/OUTPUTS: Inputs array data on the second CE# and WE# cycle during a Program
command. Data is internally latched. Outputs array and configuration data. The data pins float to
tri-state when the chip is de-selected.
CE# INPUT
CHIP ENABLE: Activates the internal control logic, input buffers, decoders and sense amplifiers.
CE# is active low. CE# high de-selects the memory device and reduces power consumption to
standby levels.
OE# INPUT OUTPUT ENABLE: Enables the device’s outputs through the data buffers during a Read
operation. OE# is active low.
WE# INPUT WRITE ENABLE: Controls writes to the command register and memory array. WE# is active low.
Addresses and data are latched on the rising edge of the second WE# pulse.
RP# INPUT
RESET/DEEP POWER-DOWN: Uses two voltage levels (VIL,V
IH) to control reset/deep power-
down mode.
WhenRP#isatlogiclow,thedeviceisinreset/deeppower-downmode, which drives the
outputs to High-Z, resets the Write State Machine, and minimizes current levels (ICCD).
When RP# is at logic high, the device is in standard operation. When RP# transitions from
logic-low to logic-high, the device resets all blocks to locked and defaults to the read array mode.
WP# INPUT
WRITE PROTECT: Controls the lock-down function of the flexible locking feature.
When WP# is a logic low, the lock-down mechanism is enabled and blocks marked lock-down
cannot be unlocked through software.
When WP# is logic high, the lock-down mechanism is disabled and blocks previously locked-
down are now locked and can be unlocked and locked through software. After WP# goes low, any
blocks previously marked lock-down revert to that state.
See Section 4.3 for details on block locking.
VCC SUPPLY DEVICE POWER SUPPLY: [2.7 V–3.6 V] Supplies power for device operations.
VCCQ INPUT
I/O POWER SUPPLY: Enablesalloutputstobedrivento1.8V–2.5VwhiletheV
CC is at 2.7 V–
3.3V.IftheV
CC is regulated to 2.7 V–2.85 V, VCCQ canbedrivenat1.65V2.5Vtoachieve
lowest power operation (see Section 5.4).ThisinputmaybetieddirectlytoV
CC (2.7 V–3.6 V).
VPP
INPUT/
SUPPLY
PROGRAM/ERASE POWER SUPPLY: [1.65 V–3.6 V or 11.4 V–12.6 V] Operates as a input at
logic levels to control complete device protection. Supplies power for accelerated Program and
Erase operations in 12 V ±5% range. This pin cannot be left floating.
Lower VPP VPPLK, to protect all contents against Program and Erase commands.
Set VPP =V
CC for in-system Read, Program and Erase operations. In this configuration, VPP
can drop as low as 1.65 V to allow for resistor or diode drop from the system supply. Note that if
VPP is driven by a logic signal, VIH = 1.65. That is, VPP must remain above 1.65 V to perform in-
system flash modifications.
Raise VPP to 12 V ±5% for faster program and erase in a production environment. Applying 12 V
±5% to VPP can only be done for a maximum of 1000 cycles on the main blocks and 2500 cycles
on the parameter blocks. VPP may be connected to 12 V for a total of 80 hours maximum. See
Section 4.4 for details on VPP voltage configurations.
VSSQ SUPPLY GROUND: For all internal circuitry. All VSSQ inputs must be connected. Same function as GND.
GND SUPPLY GROUND: For all internal circuitry. All ground inputs must be connected.
NC NO CONNECT: Pin may be driven or left floating.
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 17
3.2 Block Organization
The 3-Volt Advanced+ Boot Block is an asymmetrically blocked architecture that enables system
integration of code and data within a single flash device. Each block can be erased independently
of the others up to 100,000 times. For the address locations of each block, see the memory maps in
Appendix E.
3.2.1 Parameter Blocks
The 3-Volt Advanced+ Boot Block flash memory architecture includes parameter blocks to
facilitate storage of frequently updated small parameters (i.e., data that would normally be stored in
an EEPROM). Each device contains eight parameter blocks of 4 Kwords (4,096 words).
3.2.2 Main Blocks
After the parameter blocks, the remainder of the array is divided into 32-Kword (32,768 words)
main blocks for data or code storage. Each 8-Mbit, 16-Mbit, 32-Mbit, or 64-Mbit device contains
15, 31, 63, or 127 main blocks, respectively.
4.0 Principles of Operation
The 3-Volt Advanced+ Boot Block flash memory family uses a CUI and automated algorithms to
simplify Program and Erase operations. The CUI allows for 100% CMOS-level control inputs and
fixed power supplies during erasure and programming.
The internal WSM completely automates Program and Erase operations while the CUI signals the
start of an operation and the status register reports status. The CUI handles the WE# interface to the
data and address latches, as well as system status requests during WSM operation.
4.1 Bus Operation
The 3-Volt Advanced+ Boot Block flash memory devices read, program, and erase in-system via
the local CPU or microcontroller. All bus cycles to or from the flash memory conform to standard
microcontroller bus cycles. Four control pins dictate the data flow in and out of the flash
component: CE#, OE#, WE#, and RP#. Table 3 on page 18 summarizes these bus operations.
4.1.1 Read
The flash memory has four read modes available: read array, read configuration, read status, and
read query. These modes are accessible independent of the VPP voltage. The appropriate Read
Mode command must be issued to the CUI to enter the corresponding mode. Upon initial device
power-up or after exit from reset, the device automatically defaults to read-array mode.
CE# and OE# must be driven active to obtain data at the outputs. CE# is the device selection
control; when active it enables the flash memory device. OE# is the data output control, and it
drives the selected memory data onto the I/O bus. For all read modes, WE# and RP# must be at
VIH.Figure 9, AC Waveform: Read Operations” on page 42 illustrates a read cycle.
28F800C3, 28F160C3, 28F320C3, 28F640C3
18 Datasheet
4.1.2 Output Disable
With OE# at a logic-high level (VIH), the device outputs are disabled. Output pins are placed in a
high-impedance state.
4.1.3 Standby
Deselecting the device by bringing CE# to a logic-high level (VIH) places the device in standby
mode, which substantially reduces device power consumption without any latency for subsequent
read accesses. In standby, outputs are placed in a high-impedance state independent of OE#. If
deselected during Program or Erase operation, the device continues to consume active power until
the Program or Erase operation is complete.
8-bit devices use only DQ [0:7], 16-bit devices use DQ [0:15].
4.1.4 Reset
From read mode, RP# at VIL for time tPLPH deselects the memory, places output drivers in a high-
impedance state, and turns off all internal circuits. After return from reset, a time tPHQV is required
until the initial read-access outputs are valid. A delay (tPHWL or tPHEL) is required after return from
reset before a write can be initiated. After this wake-up interval, normal operation is restored. The
CUI resets to read-array mode, the status register is set to 80H, and all blocks are locked. Figure 11,
“AC Waveform: Reset Operations” on page 49 (section A) illustrates this case.
If RP# is taken low for time tPLPH during a Program or Erase operation, the operation will be
aborted and the memory contents at the aborted location (for a program) or block (for an erase) are
no longer valid, since the data may be partially erased or written. The abort process goes through
the following sequence:
1. When RP# goes low, the device shuts down the operation in progress, a process which takes
time tPLRH to complete.
2. After this time tPLRH, the part will either reset to read-array mode (if RP# has gone high during
tPLRH,Figure 11, section B) or enter reset mode (if RP# is still logic low after tPLRH,Figure
11, section C).
Table 3. Bus Operations
Mode Notes RP# CE# OE# WE# DQ0–7 DQ8–15
Read (Array, Status, Configuration, or Query) 1, 2,3 VIH VIL VIL VIH DOUT DOUT
Output Disable 1 VIH VIL VIH VIH High Z High Z
Standby 1 VIH VIH X X High Z High Z
Reset 1,4 VIL X X X High Z High Z
Write 1,4,5,6 VIH VIL VIH VIL DIN DIN
NOTES:
1. X must be VIL,V
IH for control pins and addresses.
2. See DC Characteristics for VPPLK,V
PP1,V
PP2,V
PP3, voltages.
3. Manufacturer and device codes may also be accessed in read-configuration mode (A1–A20 =0).SeeTable4onpage20.
4. To program or erase the lockable blocks, hold WP# at VIH.
5. Refer to Table5onpage23for valid DIN during a Write operation.
6.RP#mustbeatGND± 0.2 V to meet the maximum deep power-down current specified.
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 19
3. In both cases, after returning from an aborted operation, the relevant time tPHQV or tPHWL/
tPHEL must be observed before a Read or Write operation is initiated, as discussed in the
previous paragraph. However, in this case, these delays are referenced to the end of tPLRH
rather than when RP# goes high.
As with any automated device, it is important to assert RP# during system reset. When the system
comes out of reset, the processor expects to read from the flash memory. Automated flash
memories provide status information when read during program or Block-Erase operations. If a
CPU reset occurs with no flash memory reset, proper CPU initialization may not occur because the
flash memory may be providing status information instead of array data. Intel®Flash memories
allow proper CPU initialization following a system reset through the use of the RP# input. In this
application, RP# is controlled by the same RESET# signal that resets the system CPU.
4.1.5 Write
A write occurs when both CE# and WE# are low and OE# is high. Commands are written to the
Command User Interface (CUI) using standard microprocessor write timings to control Flash
operations. The CUI does not occupy an addressable memory location. The address and data buses
are latched on the rising edge of the second WE# or CE# pulse, whichever occurs first. See Figure
10, “AC Waveform: Program and Erase Operations” on page 48. The available commands are
shown in Table 6 on page 24,andAppendix A provides detailed information on moving between
the different modes of operation using CUI commands.
Two commands modify array data: Program (40H), and Erase (20H). Writing either of these
commands to the internal Command User Interface (CUI) initiates a sequence of internally timed
functions that culminate in the completion of the requested task (unless that operation is aborted by
either RP# being driven to VIL for tPLRH or an appropriate Suspend command).
4.2 Modes of Operation
The flash memory has four read modes (read array, read configuration, read status, and read query),
and two write modes (program and erase). Three additional modes (erase suspend to program,
erase suspend to read, and program suspend to read) are available only during suspended
operations. Tables 5 and 6 summarize the commands used to reach these modes. Appendix A is a
comprehensive chart showing the state transitions.
4.2.1 Read Array
When RP# transitions from VIL (reset) to VIH, the device defaults to read-array mode and will
respond to the read-control inputs (CE#, address inputs, and OE#) without any additional CUI
commands.
When the device is in read array mode, four control signals control data output.
WE# must be logic high (VIH)
CE# must be logic low (VIL)
OE# must be logic low (VIL)
RP#mustbelogichigh(V
IH)
28F800C3, 28F160C3, 28F320C3, 28F640C3
20 Datasheet
In addition, the address of the desired location must be applied to the address pins. If the device is
not in read-array mode, as would be the case after a Program or Erase operation, the Read Array
command (FFH) must be written to the CUI before array reads can occur.
4.2.2 Read Configuration
The read-configuration mode outputs three types of information: the manufacturer/device
identifier, the block locking status, and the protection register. The device is switched to this mode
by writing the Read Configuration command (90H). Once in this mode, read cycles from addresses
shown in Table 4 retrieve the specified information. To return to read-array mode, write the Read
Array command (FFH).
4.2.3 Read Status Register
The status register indicates the status of device operations, and the success/failure of that
operation. The Read Status Register (70H) command causes subsequent reads to output data from
the status register until another command is issued. To return to reading from the array, issue a
Read Array (FFH) command.
The status-register bits are output on DQ0–DQ7. The upper byte, DQ8–DQ15, outputs 00H during a
Read Status Register command.
The contents of the status register are latched on the falling edge of OE# or CE# (whichever occurs
last), which prevents possible bus errors that might occur if status register contents change while
being read. CE# or OE# must be toggled with each subsequent status read, or the status register
will not indicate completion of a Program or Erase operation.
When the WSM is active, SR.7 will indicate the status of the WSM; the remaining bits in the status
register indicate whether the WSM was successful in performing the preferred operation (see
Table 7, “Status Register Bit Definition” on page 25).
Table 4. Read Configuration Table
Item Address Data
Manufacturer Code (x16) 00000 0089
Device ID (See Appendix F) 00001 ID
Block Lock Configuration(1) XX002(2) LOCK
BlockIsUnlocked DQ
0=0
Block Is Locked DQ0=1
Block Is Locked-Down DQ1=1
Protection Register Lock(3) 80 PR-LK
Protection Register (x16) 81–88 PR
NOTES:
1. See Section 4.3.4 for valid lock-status outputs.
2. “XX” specifies the block address of lock configuration being read.
3. See Section 4.4 for protection register information.
4. Other locations within the configuration address space are reserved
by Intel for future use.
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 21
4.2.3.1 Clearing the Status Register
The WSM sets status bits 1 through 7 to “1,” and clears bits 2, 6, and 7 to 0,” but cannot clear
status bits 1 or 3 through 5 to “0.” Because bits 1, 3, 4, and 5 indicate various error conditions,
these bits can be cleared only through the Clear Status Register (50H) command. By allowing the
system software to control the resetting of these bits, several operations may be performed (such as
cumulatively programming several addresses or erasing multiple blocks in sequence) before
reading the status register to determine if an error occurred during that series. Clear the status
register before beginning another command or sequence. Note that this is different from a burst
device. The Read Array command must be issued before data can be read from the memory array.
Resetting the device also clears the status register.
4.2.4 Read Query
The read-query mode outputs Common Flash Interface (CFI) data when the device is read, and can
be accessed by writing the Read Query Command (98H). The CFI data structure contains
information such as block size, density, command set, and electrical specifications. Once in this
mode, read cycles from addresses shown in Appendix C retrieve the specified information. To
return to read-array mode, write the Read Array command (FFH).
4.2.5 Program Mode
Programming is executed using a two-write sequence. The Program Setup command (40H) is
written to the CUI followed by a second write which specifies the address and data to be
programmed. The WSM will execute a sequence of internally timed events to program preferred
bits of the addressed location, then verify the bits are sufficiently programmed. Programming the
memory results in specific bits within an address location being changed to a “0.” If users attempt
to program “1”s, the memory cell contents do not change and no error occurs.
The status register indicates programming status: while the program sequence executes, status bit 7
is “0.” The status register can be polled by toggling either CE# or OE#. While programming, the
only valid commands are Read Status Register, Program Suspend, and Program Resume.
When programming is complete, the program-status bits should be checked. If the programming
operation was unsuccessful, bit SR.4 of the status register is set to indicate a program failure. If
SR.3 is set, then VPP was not within acceptable limits, and the WSM did not execute the program
command. If SR.1 is set, a program operation was attempted on a locked block and the operation
was aborted.
The status register should be cleared before attempting the next operation. Any CUI instruction can
follow after programming is completed; however, to prevent inadvertent status-register reads, be
sure to reset the CUI to read-array mode.
4.2.5.1 Suspending and Resuming Program
The Program Suspend command halts an in-progress program operation so that data can be read
from other locations of memory. Once the programming process starts, writing the Program
Suspend command to the CUI requests that the WSM suspend the program sequence (at
predetermined points in the program algorithm). The device continues to output status-register data
after the Program Suspend command is written. Polling status-register bits SR.7 and SR.2 will
determine when the program operation has been suspended (both will be set to “1”). tWHRH1/
tEHRH1 specify the program-suspend latency.
28F800C3, 28F160C3, 28F320C3, 28F640C3
22 Datasheet
A Read Array command can now be written to the CUI to read data from blocks other than that
which is suspended. The only other valid commands while program is suspended are Read Status
Register, Read Configuration, Read Query, and Program Resume. After the Program Resume
command is written to the flash memory, the WSM will continue with the programming process
and status register bits SR.2 and SR.7 will automatically be cleared. The device automatically
outputs status register data when read (see Figure 13, “Program Suspend/Resume Flowchart” on
page 53) after the Program Resume command is written. VPP must remain at the same VPP level
used for program while in program-suspend mode. RP# must also remain at VIH.
4.2.6 Erase Mode
To erase a block, write the Erase Set-up and Erase Confirm commands to the CUI, along with an
address identifying the block to be erased. This address is latched internally when the Erase
Confirm command is issued. Block erasure results in all bits within the block being set to 1.” Only
one block can be erased at a time. The WSM will execute a sequence of internally timed events to
program all bits within the block to “0,” erase all bits within the block to “1,” then verify that all
bits within the block are sufficiently erased. While the erase executes, status bit 7 is a “0.”
When the status register indicates that erasure is complete, check the erase-status bit to verify that
the Erase operation was successful. If the Erase operation was unsuccessful, SR.5 of the status
register will be set to a “1, indicating an erase failure. If VPP was not within acceptable limits after
the Erase Confirm command was issued, the WSM will not execute the erase sequence; instead,
SR.5 of the status register is set to indicate an erase error, and SR.3 is set to a “1” to identify that
VPP supply voltage was not within acceptable limits.
After an Erase operation, clear the status register (50H) before attempting the next operation. Any
CUI instruction can follow after erasure is completed; however, to prevent inadvertent status-
register reads, it is advisable to place the flash in read-array mode after the erase is complete.
4.2.6.1 Suspending and Resuming Erase
Since an Erase operation requires on the order of seconds to complete, an Erase Suspend command
is provided to allow erase-sequence interruption in order to read data from—or program data to—
another block in memory. Once the erase sequence is started, writing the Erase Suspend command
to the CUI suspends the erase sequence at a predetermined point in the erase algorithm. The status
register will indicate if/when the Erase operation has been suspended. Erase-suspend latency is
specified by tWHRH2/tEHRH2.
A Read Array/Program command can now be written to the CUI to read/program data from/to
blocks other than that which is suspended. This nested Program command can subsequently be
suspended to read yet another location. The only valid commands while Erase is suspended are
Read Status Register, Read Configuration, Read Query, Program Setup, Program Resume, Erase
Resume, Lock Block, Unlock Block, and Lock-Down Block. During erase-suspend mode, the chip
can be placed in a pseudo-standby mode by taking CE# to VIH, which reduces active current
consumption.
Erase Resume continues the erase sequence when CE# = VIL. Similar to the end of a standard
Erase operation, the status register must be read and cleared before the next instruction is issued.
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 23
Bus operations are defined in Table 3, “Bus Operations” on page 18.
Table 5. Command Bus Operations
Command Notes
First Bus Cycle Second Bus Cycle
Oper Addr Data Oper Addr Data
Read Array 1 Write X FFH
Read Configuration 1, 2 Write X 90H Read IA ID
Read Query 1, 2 Write X 98H Read QA QD
Read Status Register 1 Write X 70H Read X SRD
Clear Status Register 1 Write X 50H
Program 1, 3 Write X 40H/10H Write PA PD
Block Erase/Confirm 1 Write X 20H Write BA D0H
Program/Erase Suspend 1 Write X B0H
Program/Erase Resume 1 Write X D0H
Lock Block 1 Write X 60H Write BA 01H
Unlock Block 1 Write X 60H Write BA D0H
Lock-Down Block 1 Write X 60H Write BA 2FH
Protection Program 1 Write X C0H Write PA PD
X = "Don’t Care" PA = Prog Addr BA = Block Addr IA =Identifier Addr. QA = Query Addr.
SRD = Status Reg.
Data PD = Prog Data ID = Identifier Data QD = Query Data
NOTES:
1. Following the Read Configuration or Read Query commands, Read operations output device configuration
or CFI query information, respectively. See Section 4.2.2 and Section 4.2.4.
2. Either 40H or 10H command is valid, but the Intel standard is 40H.
3. When writing commands, the upper data bus [DQ8–DQ15] should be either VIL or VIH, to minimize current
draw.
28F800C3, 28F160C3, 28F320C3, 28F640C3
24 Datasheet
Table 6. Command Codes and Descriptions
Code Device Mode Description
FF Read Array This command places the device in read-array mode, which outputs array data on the data
pins.
40 Program Set-Up
This is a two-cycle command. The first cycle prepares the CUI for a program operation. The
second cycle latches addresses and data information and initiates the WSM to execute the
Program algorithm. The flash outputs status-register data when CE# or OE# is toggled. A Read
Array command is required after programming to read array data. See Section 4.2.5.
20 Erase Set-Up
Prepares the CUI for the Erase Confirm command. If the next command is not an Erase
Confirm command, then the CUI will (a) set both SR.4 and SR.5 of the status register to a “1,
(b) place the device into the read-status-register mode, and (c) wait for another command. See
Section 4.2.6.
D0
Erase Confirm
Program/Erase
Resume
Unlock Block
If the previous command was an Erase Set-Up command, then the CUI will close the address
and data latches and begin erasing the block indicated on the address pins. During program/
erase, the device will respond only to the Read Status Register, Program Suspend and Erase
Suspend commands, and will output status-register data when CE# or OE# is toggled.
If a Program or Erase operation was previously suspended, this command will resume that
operation.
If the previous command was Configuration Set-Up, the CUI will latch the address and unlock
the block indicated on the address pins. If the block had been previously set to Lock-Down, this
operation will have no effect. (Section 4.3)
B0
Program Suspend
Erase
Suspend
Issuing this command will begin to suspend the currently executing Program/Erase operation.
The status register will indicate when the operation has been successfully suspended by
setting either the program-suspend (SR.2) or erase-suspend (SR.6) and the WSM status bit
(SR.7) to a “1” (ready). The WSM will continue to idle in the SUSPEND state, regardless of the
state of all input-control pins except RP#, which will immediately shut down the WSM and the
remainder of the chip if RP# is driven to VIL. See Sections 3.2.5.1 and 3.2.6.1.
70 Read Status
Register
This command places the device into read-status-register mode. Reading the device will
output the contents of the status register, regardless of the address presented to the device.
The device automatically enters this mode after a Program or Erase operation has been
initiated. See Section 4.2.3.
50 Clear Status
Register
The WSM can set the block-lock status (SR.1), VPP Status (SR.3), program status (SR.4), and
erase-status (SR.5) bits in the status register to “1,” but it cannot clear them to “0. Issuing this
command clears those bits to “0.”
90 Read
Configuration
Puts the device into the read-configuration mode so that reading the device will output the
manufacturer/device codes or block-lock status. Section 4.2.2.
60 Configuration
Set-Up
Prepares the CUI for changes to the device configuration, such as block-locking changes. If
the next command is not Block Unlock, Block Lock, or Block Lock-Down, then the CUI will set
both the program and erase-status-register bits to indicate a command-sequence error. See
Section 4.2.
01 Lock-Block If the previous command was Configuration Set-Up, the CUI will latch the address and lock the
block indicated on the address pins. (Section 4.3)
2F Lock-Down If the previous command was a Configuration Set-Up command, the CUI will latch the address
and lock-down the block indicated on the address pins. (Section 4.3)
98 Read
Query
Puts the device into the read-query mode so that reading the device will output Common Flash
Interface information. See Section 4.2.4 and Appendix C.
C0
Protection
Program
Setup
This is a two-cycle command. The first cycle prepares the CUI for a program operation to the
protection register. The second cycle latches addresses and data information and initiates the
WSM to execute the Protection Program algorithm to the protection register. The flash outputs
status-register data when CE# or OE# is toggled. A Read Array command is required after
programming to read array data. See Section 4.4.
10 Alt. Prog Set-Up Operates the same as Program Set-up command. (See 40H/Program Set-Up)
00 Invalid/
Reserved
Unassigned commands that should not be used. Intel reserves the right to redefine these
codes for future functions.
NOTE: See Appendix A for mode transition information.
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 25
4.3 Flexible Block Locking
Intel 3-Volt Advanced+ Boot Block products offer an instant, individual block-locking scheme that
allows any block to be locked or unlocked with no latency, enabling instant code and data
protection.
This locking scheme offers two levels of protection. The first level allows software-only control of
block locking (useful for data blocks that change frequently), while the second level requires
hardware interaction before locking can be changed (useful for code blocks that change
infrequently).
The following sections will discuss the operation of the locking system. The term “state [XYZ]”
will be used to specify locking states; e.g., state [001],” where X = value of WP#, Y = bit DQ1of
the Block Lock status register, and Z = bit DQ0of the Block Lock status register. Table 9, Block
Locking State Transitions” on page 28 defines all of these possible locking states.
Table 7. Status Register Bit Definition
WSMS ESS ES PS VPPS PSS BLS R
76543210
NOTES:
SR.7 WRITE STATE MACHINE STATUS (WSMS)
1=Ready
0=Busy
Check Write State Machine bit first to determine Word Program
or Block Erase completion, before checking program or erase-
status bits.
SR.6 = ERASE-SUSPEND STATUS (ESS)
1 = Erase Suspended
0 = Erase In Progress/Completed
When Erase Suspend is issued, WSM halts execution and sets
both WSMS and ESS bits to 1.” ESS bit remains set to “1” until
an Erase Resume command is issued.
SR.5 = ERASE STATUS (ES)
1=ErrorInBlockErase
0 = Successful Block Erase
When this bit is set to 1,” WSM has applied the max. number
of erase pulses to the block and is still unable to verify
successful block erasure.
SR.4 = PROGRAM STATUS (PS)
1 = Error in Programming
0 = Successful Programming
When this bit is set to “1,” WSM has attempted but failed to
program a word/byte.
SR.3 = VPP STATUS (VPPS)
1=V
PP Low Detect, Operation Abort
0=V
PP OK
The VPP status bit does not provide continuous indication of
VPP level. The WSM interrogates VPP level only after the
Program or Erase command sequences have been entered,
and informs the system if VPP has not been switched on. The
VPP is also checked before the operation is verified by the
WSM. The VPP status bit is not guaranteed to report accurate
feedback between VPPLK and VPP1Min.
SR.2 = PROGRAM SUSPEND STATUS (PSS)
1 = Program Suspended
0 = Program in Progress/Completed
When Program Suspend is issued, WSM halts execution and
sets both WSMS and PSS bits to “1.” PSS bit remains set to “1
until a Program Resume command is issued.
SR.1 = BLOCK LOCK STATUS
1=Prog/Eraseattemptedonalockedblock;Operation
aborted.
0 = No operation to locked blocks
If a Program or Erase operation is attempted to one of the
locked blocks, this bit is set by the WSM. The operation
specified is aborted and the device is returned to read status
mode.
SR.0 = RESERVED FOR FUTURE ENHANCEMENTS (R) This bit is reserved for future use and should be masked out
when polling the status register.
NOTE: A Command-Sequence Error is indicated when SR.4, SR.5, and SR.7 are set.
28F800C3, 28F160C3, 28F320C3, 28F640C3
26 Datasheet
4.3.1 Locking Operation
The following concisely summarizes the locking functionality.
All blocks power-up locked, then can be unlocked or locked with the Unlock and Lock
commands.
The Lock-Down command locks a block and prevents it from being unlocked when WP# = 0.
When WP# = 1, Lock-Down is overridden and commands can unlock/lock locked-down
blocks.
When WP# returns to 0, locked-down blocks return to Lock Down.
Lock Down is cleared only when the device is reset or powered down.
The locking status of each block can be set to Locked, Unlocked, and Lock Down, each of which
will be described in the following sections. Table 9 on page 28 is a comprehensive state table for
the locking functions; Figure 16 on page 56 is a flowchart for Locking operations.
4.3.1.1 Locked State
The default status of all blocks upon power-up or reset is locked (states [001] or [101]). Locked
blocks are fully protected from alteration. Any Program or Erase operations attempted on a locked
block will return an error on bit SR.1 of the status register. The status of a locked block can be
changed to Unlocked or Lock Down using the appropriate software commands. An Unlocked
block can be locked by writing the Lock command sequence, 60H followed by 01H.
4.3.2 Unlocked State
Unlocked blocks (states [000], [100], [110]) can be programmed or erased. All unlocked blocks
return to the Locked state when the device is reset or powered down. The status of an unlocked
block can be changed to Locked or Locked Down using the appropriate software commands. A
Locked block can be unlocked by writing the Unlock command sequence, 60H followed by D0H.
4.3.3 Lock-Down State
Blocks that are Locked Down (state [011]) are protected from Program and Erase operations (just
like Locked blocks), but their protection status cannot be changed using software commands alone.
A Locked or Unlocked block can be Locked Down by writing the Lock-Down command sequence,
60H followed by 2FH. Locked-Down blocks revert to the Locked state when the device is reset or
powered down.
The Lock-Down function depends on the WP# input pin. When WP# = 0, blocks in Lock Down
[011] are protected from program, erase, and lock status changes. When WP# = 1, the Lock-Down
function is disabled ([111]) and Locked-Down blocks can be individually unlocked by software
command to the [110] state, where they can be erased and programmed. These blocks can then be
relocked [111] and unlocked [110] as required while WP# remains high. When WP# goes low,
blocks that were previously Locked Down return to the Lock-Down state [011], regardless of any
changes made while WP# was high. Device reset or power-down resets all blocks, including those
in Lock-Down, to Locked state.
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 27
4.3.4 Reading Block-Lock Status
The Lock status of every block can be read in the configuration-read mode of the device. To enter
this mode, write 90H to the device. Subsequent reads at Block Address + 00002 will output the
Lock status of that block. The Lock status is represented by DQ0and DQ1.DQ
0indicates the Block
Lock/Unlock status and is set by the Lock command and cleared by the Unlock command. It is also
automatically set when entering Lock Down. DQ1indicates Lock-Down status, and is set by the
Lock-Down command. It cannot be cleared by software—only by device reset or power-down.
4.3.5 Locking Operations during Erase Suspend
Changes to block-lock status can be performed during an erase-suspend by using the standard
locking command sequences to Unlock, Lock, or Lock Down a block. This is useful in the case
when another block needs to be updated while an Erase operation is in progress.
To change block locking during an Erase operation, first write the Erase Suspend command (B0H),
then check the status register until it indicates that the Erase operation has been suspended. Next,
write the preferred Lock command sequence to a block and the Lock status will be changed. After
completing any preferred Lock, Read, or Program operations, resume the Erase operation with the
Erase Resume command (D0H).
If a block is Locked or Locked Down during a Suspended Erase of the same block, the locking
status bits will be changed immediately, but when the Erase is resumed, the Erase operation will
complete.
Locking operations cannot be performed during a Program Suspend. Refer to Appendix A for
detailed information on which commands are valid during Erase Suspend.
4.3.6 Status Register Error Checking
Using nested-locking or program-command sequences during Erase Suspend can introduce
ambiguity into status register results.
Since locking changes are performed using a two-cycle command sequence, e.g., 60H followed by
01H to lock a block, following the Configuration Setup command (60H) with an invalid command
will produce a Lock-Command error (SR.4 and SR.5 will be set to 1) in the status register. If a
Lock-CommanderroroccursduringanEraseSuspend,SR.4andSR.5willbesetto1andwill
remain at 1 after the Erase is resumed. When Erase is complete, any possible error during the Erase
cannot be detected via the status register because of the previous Lock-Command error.
A similar situation happens if an error occurs during a Program-Operation error nested within an
Erase Suspend.
Table 8. Block Lock Status
Item Address Data
Block Lock Configuration XX002 LOCK
BlockIsUnlocked DQ
0=0
BlockIsLocked DQ
0=1
Block Is Locked-Down DQ1=1
28F800C3, 28F160C3, 28F320C3, 28F640C3
28 Datasheet
4.4 128-Bit Protection Register
The 3-Volt Advanced+ Boot Block architecture includes a 128-bit protection register than can be
used to increase the security of a system design. For example, the number contained in the
protection register can be used to “mate” the flash component with other system components, such
as the CPU or ASIC, preventing device substitution. The Intel application note, AP-657 Designing
with the Advanced+ Boot Block Flash Memory Architecture, contains additional application
information.
The 128 bits of the protection register are divided into two 64-bit segments. One of the segments is
programmed at the Intel factory with a unique 64-bit number, which is unchangeable. The other
segment is left blank for customer designs to program, as preferred. Once the customer segment is
programmed, it can be locked to prevent reprogramming.
4.4.1 Reading the Protection Register
The protection register is read in the configuration-read mode. The device is switched to this mode
by writing the Read Configuration command (90H). Once in this mode, read cycles from addresses
shown in Appendix G retrieve the specified information. To return to read-array mode, write the
Read Array command (FFH).
Table 9. Block Locking State Transitions
Current State
Erase/Prog
Allowed?
Lock Command Input Result (Next State)
XYZ
Lock Unlock Lock-Down
WP# DQ1DQ0Name
0 0 0 “Unlocked Yes Goes To [001] No Change Goes To [011]
0 0 1 “Locked” (Default) No No Change Goes To [000] Goes To [011]
0 1 1 “Locked-Down” No No Change No Change No Change
1 0 0 “Unlocked Yes Goes To [101] No Change Goes To [111]
1 0 1 “Locked” No No Change Goes To [100] Goes To [111]
1 1 0 Lock-Down Disabled Yes Goes To [111] No Change Goes To [111]
1 1 1 Lock-Down Disabled No No Change Goes To [110] No Change
NOTES:
1. In this table, the notation [XYZ] denotes the locking state of a block, where X = WP#, Y = DQ1, and Z = DQ0.Thecurrent
locking state of a block is defined by the state of WP# and the two bits of the block-lock status (DQ0,DQ
1). DQ0indicates if a
block is locked (1) or unlocked (0). DQ1indicates if a block has been Locked Down (1) or not (0).
2. At power-up or device reset, all blocks default to Locked state [001] (if WP# = 0). Holding WP# = 0 is the recommended
default.
3. The “Erase/Program Allowed?” column shows whether Erase and Program operations are enabled (Yes) or disabled (No) in
that block’s current Lock state.
4. The “Lock Command Input Result [Next State]” column shows the result of writing the three Lock commands (Lock, Unlock,
Lock-Down) in the current Lock state. For example, “Goes To [001]” would mean that writing the command to a block in the
current Lock state would change it to [001].
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 29
4.4.2 Programming the Protection Register
The protection register bits are programmed using the two-cycle Protection Program command.
The 64-bit number is programmed 16 bits at a time for word-wide parts, and eight bits at a time for
byte-wide parts.
First, write the Protection Program Setup command, C0H. The next write to the device will latch in
address and data, and program the specified location. The allowable addresses are shown in
Appendix G.SeeFigure 17, “Protection Register Programming Flowchart” on page 57. Attempts
to address Protection Program commands outside the defined protection register address space
should not be attempted. This space is reserved for future use. Attempting to program to a
previously locked protection register segment will result in a Status Register error (Program Error
bit SR.4 and Lock Error bit SR.1 will be set to 1).
4.4.3 Locking the Protection Register
The user-programmable segment of the protection register is lockable by programming Bit 1 of the
PR-LOCK location to 0. Bit 0 of this location is programmed to 0 at the Intel factory to protect the
unique device number. This bit is set using the Protection Program command to program “FFFD”
to the PR-LOCK location. After these bits have been programmed, no further changes can be made
to the values stored in the protection register. Protection Program commands to a locked section
will result in a Status Register error (Program Error bit SR.4 and Lock Error bit SR.1 will be set to
1). Protection register lockout state is not reversible.
0645_05
4.5 VPP Program and Erase Voltages
Intel 3-Volt Advanced+ Boot Block products provide in-system programming and erase in the
1.65 V–3.6 V range. For fast production programming, it also includes a low-cost, backward-
compatible 12-V programming feature.
4.5.1 Improved 12-Volt Production Programming
When VPP is between 1.65 V and 3.6 V, all program and erase current is drawn through the VCC
pin. Note that if VPP is driven by a logic signal, VIH min = 1.65 V. That is, VPP must remain above
1.65 V to perform in-system flash modifications. When VPP is connected to a 12 V power supply,
Figure 5. Protection Register Memory Map
4 Words
Factory Programmed
4 Words
User Programmed
PR Lock
88H
85H
84H
81H
80H
28F800C3, 28F160C3, 28F320C3, 28F640C3
30 Datasheet
the device draws program and erase current directly from the VPP pin. This eliminates the need for
an external switching transistor to control the voltage VPP
.Figure6onpage30shows examples of
how the flash power supplies can be configured for various usage models.
The 12-V VPP mode enhances programming performance during the short period of time typically
found in manufacturing processes; however, it is not intended for extended use. 12 V may be
applied to VPP during Program and Erase operations for a maximum of 1000 cycles on the main
blocks and 2500 cycles on the parameter blocks. VPP may be connected to 12 V for a total of 80
hours maximum. Stressing the device beyond these limits may cause permanent damage.
4.5.2 VPP VPPLK for Complete Protection
In addition to the flexible block locking, the VPP programming voltage can be held low for absolute
hardware write protection of all blocks in the flash device. When VPP is below VPPLK,any
Program or Erase operation will result in a error, prompting the corresponding status-register bit
(SR.3) to be set.
0645_06
NOTE:
1. A resistor can be used if the VCC supply can sink adequate current based on resistor value. See AP-657
Designing with the Advanced+ Boot Block Flash Memory Architecture for details.
4.6 Power Consumption
Intel Flash devices have a tiered approach to power savings that can significantly reduce overall
system power consumption. The Automatic Power Savings (APS) feature reduces power
consumption when the device is selected but idle. If the CE# is deasserted, the flash enters its
standby mode, where current consumption is even lower. The combination of these features can
minimize memory power consumption, and therefore, overall system power consumption.
Figure 6. Example Power Supply Configurations
V
CC
V
PP
12 V Fast Programming
Absolute Write Protection With V
PP
V
PPLK
System Supply
12 V Supply
10
K
V
CC
V
PP
System Supply
12 V Supply
Low Voltage and 12 V Fast Programming
V
CC
V
PP
System Supply
Prot#
(Logic Signal)
V
CC
V
PP
System Supply
Low-Voltage Programming
Low-Voltage Programming
Absolute Write Protection via Logic Signal
(Note 1)
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 31
4.6.1 Active Power (Program/Erase/Read)
With CE# at a logic-low level and RP# at a logic-high level, the device is in the active mode. Refer
to the DC Characteristic tables for ICC current values. Active power is the largest contributor to
overall system power consumption. Minimizing the active current could have a profound effect on
system power consumption, especially for battery-operated devices.
4.6.2 Automatic Power Savings (APS)
Automatic Power Savings provides low-power operation during read mode. After data is read from
the memory array and the address lines are quiescent, APS circuitry places the device in a mode
where typical current is comparable to ICCS. The flash stays in this static state with outputs valid
until a new location is read.
4.6.3 Standby Power
When CE# is at a logic-high level (VIH) and the device is in read mode, the flash memory is in
standby mode, which disables much of the device’s circuitry and substantially reduces power
consumption. Outputs are placed in a high-impedance state independent of the status of the OE#
signal. If CE# transitions to a logic-high level during Erase or Program operations, the device will
continue to perform the operation and consume corresponding active power until the operation is
completed.
System engineers should analyze the breakdown of standby time versus active time, and quantify
the respective power consumption in each mode for their specific application. This approach will
provide a more accurate measure of application-specific power and energy requirements.
4.6.4 Deep Power-Down Mode
The deep power-down mode is activated when RP# = VIL (GND ±0.2 V). During read modes,
RP# going low de-selects the memory and places the outputs in a high-impedance state. Recovery
from deep power-down requires a minimum time of tPHQV for Read operations, and tPHWL/tPHEL
for Write operations.
During program or erase modes, RP# transitioning low will abort the in-progress operation. The
memory contents of the address being programmed or the block being erased are no longer valid as
the data integrity has been compromised by the abort. During deep power-down, all internal
circuits are switched to a low-power savings mode (RP# transitioning to VIL or turning off power
to the device clears the status register).
4.7 Power and Reset Considerations
4.7.1 Power-Up/Down Characteristics
In order to prevent any condition that may result in a spurious write or erase operation, it is
recommended to power-up VCC, VCCQ and S-VCC together. Conversely, VCC and VCCQ must
power-down together.
It is also recommended to power-up VPP with or slightly after VCC. Conversely, VPP must
powerdown with or slightly before VCC.
28F800C3, 28F160C3, 28F320C3, 28F640C3
32 Datasheet
If VCCQ and/or VPP are not connected to the VCC supply, then VCC should attain VCCMin
before applying VCCQ and VPP. Device inputs should not be driven before supply voltage =
VCCMin.
Power supply transitions should only occur when RP# is low.
4.7.2 RP# Connected to System Reset
The use of RP# during system reset is important with automated program/erase devices since the
system expects to read from the flash memory when it comes out of reset. If a CPU reset occurs
without a flash memory reset, proper CPU initialization will not occur because the flash memory
may be providing status information instead of array data. Intel recommends connecting RP# to the
system CPU RESET# signal to allow proper CPU/flash initialization following system reset.
System designers must guard against spurious writes when VCC voltages are above VLKO. Because
both WE# and CE# must be low for a command write, driving either signal to VIH will inhibit
writes to the device. The CUI architecture provides additional protection since alteration of
memory contents can only occur after successful completion of the two-step command sequences.
The device is also disabled until RP# is brought to VIH, regardless of the state of its control inputs.
By holding the device in reset (RP# connected to system POWERGOOD) during power-up/down,
invalid bus conditions during power-up can be masked, providing yet another level of memory
protection.
4.7.3 VCC,V
PP and RP# Transitions
The CUI latches commands as issued by system software and is not altered by VPP or CE#
transitions or WSM actions. Its default state upon power-up, after exit from reset mode or after
VCC transitions above VLKO (Lockout voltage), is read-array mode.
After any program or Block-Erase operation is complete (even after VPP transitions down to
VPPLK), the CUI must be reset to read-array mode via the Read Array command if access to the
flash-memory array is desired.
4.8 Power Supply Decoupling
Flash memory power-switching characteristics require careful device decoupling. System
designers should consider the following three supply current issues:
Standby current levels (ICCS)
Read current levels (ICCR)
Transient peaks produced by falling and rising edges of CE#.
Transient current magnitudes depend on the device outputs’ capacitive and inductive loading. Two-
line control and proper decoupling capacitor selection will suppress these transient voltage peaks.
Each flash device should have a 0.1 µF ceramic capacitor connected between each VCC and GND,
and between its VPP and GND. These high- frequency, inherently low-inductance capacitors should
be placed as close as possible to the package leads.
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 33
5.0 Electrical Specifications
5.1 Absolute Maximum Ratings
Warning: Stressing the device beyond the “Absolute Maximum Ratings” may cause permanent damage.
These are stress ratings only. Operation beyond the “Operating Conditions” is not recommended
and extended exposure beyond the “Operating Conditions” may affect device reliability
.
NOTICE: Specifications are subject to change without notice. Verify with your local Intel Sales office that you have
the latest datasheet before finalizing a design.
Parameter Maximum Rating
Extended Operating Temperature
During Read –40 °C to +85 °C
During Block Erase and Program –40 °C to +85 °C
Temperature under Bias –40 °C to +85 °C
Storage Temperature –65 °C to +125 °C
VoltageOnAnyPin(exceptV
CC and VPP) with Respect to GND –0.5 V to +3.7 V(1)
VPP Voltage (for Block Erase and Program) with Respect to GND –0.5 V to +13.5 V(1,2,3)
VCC and VCCQ Supply Voltage with Respect to GND –0.2 V to +3.6 V
Output Short Circuit Current 100 mA(4)
NOTES:
1. Minimum DC voltage is 0.5 V on input/output pins. During transitions, this level may
undershoot to –2.0 V for periods <20 ns. Maximum DC voltage on input/output pins is VCC
+0.5 V which, during transitions, may overshoot to VCC +2.0 V for periods <20 ns.
2. Maximum DC voltage on VPP may overshoot to +14.0 V for periods <20 ns.
3. VPP Program voltage is normally 1.65 V–3.6 V. Connection to a 11.4 V–12.6 V supply can be
done for a maximum of 1000 cycles on the main blocks and 2500 cycles on the parameter
blocks during program/erase. VPP may be connected to 12 V for a total of 80 hours maximum.
See Section 4.5 for details.
4. Output shorted for no more than one second. No more than one output shorted at a time.
28F800C3, 28F160C3, 28F320C3, 28F640C3
34 Datasheet
5.2 Operating Conditions
5.3 Capacitance
TA= 25 °C, f = 1 MHz
Table 10. Temperature and Voltage Operating Conditions
Symbol Parameter Notes Min Max Units
TAOperating Temperature –40 +85 °C
VCC1 VCC Supply Voltage 1, 2 2.7 3.6 Volts
VCC2 1, 2 3.0 3.6
VCCQ1
I/O Supply Voltage
12.73.6
VoltsVCCQ2 1.65 2.5
VCCQ3 1.8 2.5
VPP1 Supply Voltage 1 1.65 3.6 Volts
VPP2 1, 3 11.4 12.6 Volts
Cycling Block Erase Cycling 3 100,000 Cycles
NOTES:
1. VCC and VCCQ must share the same supply when they are in the VCC1 range.
2. VCCMax = 3.3 V for 0.25µm 32-Mbit devices.
3. Applying VPP = 11.4 V–12.6 V during a program/erase can only be done for a maximum of 1000 cycles on
the main blocks and 2500 cycles on the parameter blocks. VPP maybeconnectedto12Vforatotalof
80 hours maximum. See Section 4.5 for details.
Sym Parameter Notes Typ Max Units Conditions
CIN Input Capacitance 1 6 8 pF VIN =0V
COUT Output Capacitance 1 10 12 pF VOUT =0V
NOTE: Sampled, not 100% tested.
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 35
5.4 DC Characteristics
Sym Parameter
VCC 2.7V3.6V 2.7V2.85V 2.7V3.3V
Unit Test ConditionsVCCQ 2.7 V–3.6 V 1.65 V–2.5 V 1.8 V–2.5 V
Note Typ Max Typ Max Typ Max
ILI Input Load Current 1,2 ±1±1±A
VCC =V
CCMax
VCCQ =V
CCQMax
VIN =V
CCQ or GND
ILO
Output Leakage
Current 1,2 0.2 ±10 0.2 ±10 0.2 ±10 µA
VCC =V
CCMax
VCCQ =V
CCQMax
VIN =V
CCQ or GND
ICCS
VCC Standby
Current for 0.13
and0.18Micron
Product
1 7 15 20 50 150 250 µA VCC =V
CCMax
CE# = RP# = VCCQ
or during Program/
Erase Suspend
WP# = VCCQ or GND
VCC Standby
Current for 0.25
Micron Product
110252050150250µA
ICCD
VCC Power-Down
Current for 0.13
and0.18Micron
Product
1,2 7 15 7 20 7 20 µA VCC =V
CCMax
VCCQ =V
CCQMax
VIN =V
CCQ or GND
RP#=GND±0.2V
VCC Power-Down
Current for 0.25
Product
1,2 7 25 7 25 7 25 µA
ICCR
VCC Read Current
for 0.13 and 0.18
Micron Product
1,2,3 9 18 8 15 9 15 mA VCC =V
CCMax
VCCQ =V
CCQMax
OE# = VIH ,CE#=V
IL
f=5MHz,I
OUT=0 mA
Inputs = VIL or VIH
VCC Read Current
for 0.25 Micron
Product
1,2,3 10 18 8 15 9 15 mA
IPPD
VPP Deep Power-
Down Current 1 0.2 5 0.2 5 0.2 5 µA RP#=GND±0.2V
VPP VCC
ICCW
VCC Program
Current 1,4
18 55 18 55 18 55 mA VPP =VPP1,
Program in Progress
8 2210301030mA
VPP =V
PP2 (12v)
Program in Progress
ICCE VCC Erase Current 1,4
16 45 21 45 21 45 mA VPP =V
PP1,
EraseinProgress
8 1516451645mA
VPP =V
PP2 (12v) ,
EraseinProgress
ICCES
VCC Erase
Suspend Current 1,4 7 15 50 200 150 250 µA CE# = VCC, Erase
SuspendinProgress
IPPR VPP Read Current 1,4 2±15 2 ±15 2 ±15 µA VPP VCC
50 200 50 200 50 200 µA VPP >V
CC
IPPW
VPP Program
Current 1,4
0.05 0.1 0.05 0.1 0.05 0.1 mA VPP =VPP1,
Program in Progress
822822822mA
VPP =V
PP2 (12v)
Program in Progress
28F800C3, 28F160C3, 28F320C3, 28F640C3
36 Datasheet
IPPE VPP Erase Current 1,4 0.05 0.1 0.05 0.1 0.05 0.1 mA VPP =V
PP1,
EraseinProgress
VIL Input Low Voltage –0.4 VCC *
0.22 V –0.4 0.4 –0.4 0.4 V
VIH Input High Voltage 2.0 VCCQ
+0.3V
VCCQ
–0.4V
VCCQ
+0.3V
VCCQ
–0.4V
VCCQ
+0.3V V
VOL Output Low Voltage –0.1 0.1 -0.1 0.1 -0.1 0.1 V
VCC =V
CCMin
VCCQ =V
CCQMin
IOL =100µA
VOH
Output High
Voltage
VCCQ
–0.1V
VCCQ
–0.1V
VCCQ
–0.1V V
VCC =V
CCMin
VCCQ =V
CCQMin
IOH = –100 µA
VPPLK
VPP Lock-Out
Voltage 61.01.01.0V
Complete Write
Protection
VPP1 VPP during
Program / Erase
Operations
6 1.65 3.6 V
VPP2 6, 7 11.4 12.6 V
VLKO
VCC Prog/Erase
Lock Voltage 1.5 1.5 1.5 V
VLKO2
VCCQ Prog/Erase
Lock Voltage 1.2 1.2 1.2 V
NOTES:
1. All currents are in RMS unless otherwise noted. Typical values at nominal VCC,T
A=+2C.
2. The test conditions VCCMax, VCCQMax, VCCMin, and VCCQMin refer to the maximum or minimum VCC or VCCQ voltage listed
at the top of each column. VCCMax = 3.3 V for 0.25µm 32-Mbit devices.
3. Automatic Power Savings (APS) reduces ICCR to approximately standby levels in static operation (CMOS inputs).
4. Sampled, not 100% tested.
5. ICCES and ICCWS are specified with device de-selected. If device is read while in erase suspend, current draw is sum of ICCES
and ICCR. If the device is read while in program suspend, current draw is the sum of ICCWS and ICCR.
6. Erase and Program are inhibited when VPP <V
PPLK and not guaranteed outside the valid VPP ranges of VPP1 and VPP2.
7. Applying VPP = 11.4 V–12.6 V during program/erase can only be done for a maximum of 1000 cycles on the main blocks and
2500 cycles on the parameter blocks. VPP may be connected to 12 V for a total of 80 hours maximum. See Section 4.4 for
details.
Sym Parameter
VCC 2.7 V–3.6 V 2.7 V–2.85 V 2.7 V–3.3 V
Unit Test ConditionsVCCQ 2.7 V–3.6 V 1.65 V–2.5 V 1.8 V–2.5 V
Note Typ Max Typ Max Typ Max
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 37
0645_07
0645_08
Figure 7. Input/Output Reference Waveform
INPUT OUTPUT
TEST POINTS
V
CCQ
0.0
V
CCQ
2
V
CCQ
2
Figure 8. Test Configuration
Device
Under Test Out
R
1
V
CCQ
C
L
R
2
Test Configuration CL(pF) R1()R2()
2.7 V–3.6 V Standard Test 50 25K 25K
NOTE: CLincludes jig capacitance.
28F800C3, 28F160C3, 28F320C3, 28F640C3
38 Datasheet
4.5 AC Characteristics—Read Operations
#Sym Parameter
Density 8 Mbit
Unit
Product 90 ns 110 ns
VCC 3.0V–3.6V 2.7V–3.6V 3.0V–3.6V 2.7V–3.6V
Note Min Max Min Max Min Max Min Max
R1 tAVAV Read Cycle Time 80 90 100 110 ns
R2 tAVQV Address to Output Delay 80 90 100 110 ns
R3 tELQV CE# to Output Delay 1 80 90 100 110 ns
R4 tGLQV OE# to Output Delay 1 30 30 30 30 ns
R5 tPHQV RP# to Output Delay 150 150 150 150 ns
R6 tELQX CE#toOutputinLowZ 2 0 0 0 0 ns
R7 tGLQX OE# to Output in Low Z 2 0 0 0 0 ns
R8 tEHQZ CE#toOutputinHighZ 2 20 20 20 20 ns
R9 tGHQZ OE# to Output in High Z 2 20 20 20 20 ns
R10 tOH
Output Hold from
Address, CE#, or OE#
Change, Whichever
Occurs First
20 0 0 0 ns
NOTES:
1.OE#maybedelayeduptot
ELQVtGLQV after the falling edge of CE# without impact on tELQV.
2. Sampled, but not 100% tested.
3. See Figure 9, “AC Waveform: Read Operations” on page 42.
4. See Figure 7, “Input/Output Reference Waveform” on page 37 for timing measurements and maximum allowable input slew
rate.
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 39
AC Characteristics—Read Operations
#Sym
Para-
meter
Density 16 Mbit
Unit
Product 70 ns 80 ns 90 ns 110 ns
VCC 2.7 V–3.6 V 2.7 V–3.6 V 3.0 V–3.6 V 2.7 V–3.6 V 3.0 V–3.6 V 2.7 V–3.6 V
MinMaxMinMaxMinMaxMinMaxMinMaxMinMax
R1 tAVAV ReadCycleTime70808090100110ns
R2 tAVQV Address to Output
Delay 70 80 80 90 100 110 ns
R3 tELQV CE# to Output
Delay(1) 70 80 80 90 100 110 ns
R4 tGLQV OE# to Output
Delay(1) 20 20 30 30 30 30 ns
R5 tPHQV RP# to Output
Delay 150 150 150 150 150 150 ns
R6 tELQX CE# to Output in
Low Z(2) 000000ns
R7 tGLQX OE# to Output in
Low Z(2) 000000ns
R8 tEHQZ CE# to Output in
High Z(2) 20 20 20 20 20 20 ns
R9 tGHQZ OE# to Output in
High Z(2) 20 20 20 20 20 20 ns
R10 tOH
Output Hold from
Address, CE#, or
OE# Change,
Whichever Occurs
First(2)
000000ns
NOTES:
1.OE#maybedelayeduptot
ELQVtGLQV after the falling edge of CE# without impact on tELQV.
2. Sampled, but not 100% tested.
3. See Figure 9, “AC Waveform: Read Operations” on page 42.
4. See Figure 7, “Input/Output Reference Waveform” on page 37 for timing measurements and maximum allowable input slew
rate.
28F800C3, 28F160C3, 28F320C3, 28F640C3
40 Datasheet
AC Characteristics—Read Operations, continued
#Sym
Para-
meter
Density 32 Mbit
Unit
Product 70 ns 90 ns 100 ns 110 ns
VCC 2.7 V–3.6 V 2.7 V–3.6 V 3.0 V–3.3 V 2.7 V–3.3 V 3.0 V–3.3 V 2.7 V–3.3 V
Min Max Min Max Min Max Min Max Min Max Min Max
R1 tAVAV
Read Cycle Time 70 90 90 100 100 110 ns
R2 tAV QV
Address to Output
Delay 70 90 90 100 100 110 ns
R3 tELQV
CE# to Output
Delay(1) 70 90 90 100 100 110 ns
R4 tGLQV
OE# to Output
Delay(1) 20 20 30 30 30 30 ns
R5 tPHQV RP# to Output Delay 150 150 150 150 150 150 ns
R6 tELQX
CE# to Output in
Low Z(2) 000000ns
R7 tGLQX
OE# to Output in
Low Z(2) 000000ns
R8 tEHQZ
CE# to Output in
High Z(2) 20 20 20 20 20 20 ns
R9 tGHQZ
OE# to Output in
High Z(2) 20 20 20 20 20 20 ns
R10 tOH
Output Hold from
Address, CE#, or
OE# Change,
Whichever Occurs
First(2)
000000ns
NOTES:
1.OE#maybedelayeduptot
ELQVtGLQV after the falling edge of CE# without impact on tELQV.
2. Sampled, but not 100% tested.
3. See Figure 9, “AC Waveform: Read Operations” on page 42.
4. See Figure 7, “Input/Output Reference Waveform” on page 37 for timing measurements and maximum allowable input slew
rate.
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 41
AC Characteristics—Read Operations, continued
#Sym Parameter
Density 64 Mbit
Unit
Product 70 ns 80 ns
VCC 2.7 V–3.6 V 2.7 V–3.6 V
Note Min Max Min Max
R1 tAVAV Read Cycle Time 70 80 ns
R2 tAVQV Address to Output Delay 70 80 ns
R3 tELQV CE# to Output Delay 1 70 80 ns
R4 tGLQV OE# to Output Delay 1 20 20 ns
R5 tPHQV RP# to Output Delay 150 150 ns
R6 tELQX CE# to Output in Low Z 2 0 0 ns
R7 tGLQX OE# to Output in Low Z 2 0 0 ns
R8 tEHQZ CE#toOutputinHighZ 2 20 20 ns
R9 tGHQZ OE#toOutputinHighZ 2 20 20 ns
R10 tOH
Output Hold from Address, CE#, or OE#
Change, Whichever Occurs First 20 0 ns
NOTES:
1.OE#maybedelayeduptot
ELQVtGLQV after the falling edge of CE# without impact on tELQV
.
2. Sampled, but not 100% tested.
3. See Figure 9, “AC Waveform: Read Operations” on page 42.
4. See Figure 7, “Input/Output Reference Waveform” on page 37 for timing measurements and maximum
allowable input slew rate.
28F800C3, 28F160C3, 28F320C3, 28F640C3
42 Datasheet
Figure 9. AC Waveform: Read Operations
High Z
Valid Output
Address Stable
Data Valid
Device
Address Selection
Standby
ADDRESSES (A)
VIH
VIL
VIH
VIL
CE# (E)
VIH
VIL
VOH
VOL
VIH
VIL
OE# (G)
WE# (W)
DATA (D/Q)
RP# (P)
High Z
VIH
VIL
R1
R2
R4
R3
R5
R6
R7
R8
R9
R10
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 43
4.6 AC Characteristics—Write Operations
Table 11. AC Characteristics, Write Operations (sheet 1 of 2)
#Sym Parameter
Density 8 Mbit
Unit
Product 90 ns 110 ns
3.0 V 3.6 V 80 100
2.7V–3.6V 90 110
Note Min Min Min Min
W1 tPHWL /
tPHEL
RP# High Recovery to WE# (CE#) Going Low 150 150 150 150 ns
W2 tELWL /
tWLEL
CE# (WE#) Setup to WE# (CE#) Going Low 0 0 0 0 ns
W3 tWLWH /
tELEH
WE#(CE#)PulseWidth 1 50 60 70 70 ns
W4 tDVWH /
tDVEH
Data Setup to WE# (CE#) Going High 2 50 50 60 60 ns
W5 tAVW H /
tAVEH
Address Setup to WE# (CE#) Going High 2 50 60 70 70 ns
W6 tWHEH /
tEHWH
CE# (WE#) Hold Time from WE# (CE#) High 0 0 0 0 ns
W7 tWHDX /
tEHDX
Data Hold Time from WE# (CE#) High 2 0 0 0 0 ns
W8 tWHAX /
tEHAX
Address Hold Time from WE# (CE#) High 2 0 0 0 0 ns
W9 tWHWL /
tEHEL
WE# (CE#) Pulse Width High 1 30 30 30 30 ns
W10 tVPWH /
tVPEH
VPP Setup to WE# (CE#) Going High 3 200 200 200 200 ns
W11 tQVVL VPP Hold from Valid SRD 3 0 0 0 0 ns
W12 tBHWH /
tBHEH
WP# Setup to WE# (CE#) Going High 3 0 0 0 0 ns
W13 tQVBL WP# Hold from Valid SRD 3 0 0 0 0 ns
W14 tWHGL WE# High to OE# Going Low 3 30 30 30 30 ns
NOTES:
1. Write pulse width (tWP) is defined from CE# or WE# going low (whichever goes low last) to CE# or WE# going high
(whichever goes high first). Hence, tWP =t
WLWH =t
ELEH =t
WLEH =t
ELWH. Similarly, write pulse width high (tWPH) is defined
from CE# or WE# going high (whichever goes high first) to CE# or WE# going low (whichever goes low first). Hence,
tWPH =t
WHWL =t
EHEL =t
WHEL =t
EHWL.
2. Refer to Table 5, “Command Bus Operations” on page 23 for valid AIN or DIN.
3. Sampled, but not 100% tested.
4. Write timing characteristics during erase suspend are the same as during Write-only operations.
5. See Figure 7, “Input/Output Reference Waveform” on page 37 for timing measurements and maximum allowable input slew
rate.
6. See Figure 9, “AC Waveform: Read Operations” on page 42.
7. VCCMax = 3.3 V for 32-Mbit and 64-Mbit densities.
28F800C3, 28F160C3, 28F320C3, 28F640C3
44 Datasheet
Table 12. AC Characteristics, Write Operations (sheet 2 of 2)
#SymParameter
Density 16 Mbit
Unit
Product 70 ns 80 ns 90 ns 110 ns
3.0 V 3.6 V 80 100
2.7V–3.6V 70 80 90 110
Note Min Min Min Min Min Min
W1 tPHWL /
tPHEL
RP# High Recovery to WE#
(CE#) Going Low 150 150 150 150 150 150 ns
W2 tELWL /
tWLEL
CE#(WE#)SetuptoWE#
(CE#) Going Low 000000ns
W3 tWLWH /
tELEH
WE#(CE#)PulseWidth 1 455050607070ns
W4 tDVWH /
tDVEH
Data Setup to WE# (CE#)
Going High 2 404050506060ns
W5 tAVWH /
tAVEH
Address Setup to WE# (CE#)
Going High 2 505050607070ns
W6 tWHEH /
tEHWH
CE# (WE#) Hold Time from
WE# (CE#) High 000000ns
W7 tWHDX /
tEHDX
Data Hold Time from WE#
(CE#) High 2000000ns
W8 tWHAX /
tEHAX
AddressHoldTimefromWE#
(CE#) High 2000000ns
W9 tWHWL /
tEHEL
WE# (CE#) Pulse Width High 1 25 30 30 30 30 30 ns
W10 tVPWH /
tVPEH
VPP SetuptoWE#(CE#)
Going High 3 200 200 200 200 200 200 ns
W11 tQVVL VPP HoldfromValidSRD 3000000ns
W12 tBHWH /
tBHEH
WP# Setup to WE# (CE#)
Going High 3000000ns
W13 tQVBL WP#HoldfromValidSRD 3000000ns
W14 tWHGL WE#HightoOE#GoingLow3 303030303030ns
NOTES:
1. Write pulse width (tWP) is defined from CE# or WE# going low (whichever goes low last) to CE# or WE# going high
(whichever goes high first). Hence, tWP =t
WLWH =t
ELEH =t
WLEH =t
ELWH. Similarly, write pulse width high (tWPH)isdefined
from CE# or WE# going high (whichever goes high first) to CE# or WE# going low (whichever goes low first). Hence,
tWPH =t
WHWL =t
EHEL =t
WHEL =t
EHWL.
2. Refer to Table 5, “Command Bus Operations” on page 23 for valid AIN or DIN.
3. Sampled, but not 100% tested.
4. Write timing characteristics during erase suspend are the same as during Write-only operations.
5. See Figure 7, “Input/Output Reference Waveform” on page 37 for timing measurements and maximum allowable input slew
rate.
6. See Figure 9, “AC Waveform: Read Operations” on page 42.
7. VCCMax = 3.3 V for 32-Mbit and 64-Mbit densities.
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 45
AC Characteristics—Write Operations, continued
#Sym Parameter
Density 32 Mbit
Unit
Product 70 ns 90 ns 100 ns 110 ns
3.0 V 3.6 V(4) 90 100
2.7 V 3.6 V(4) 70 90 100 110
Note Min Min Min Min Min Min
W1 tPHWL /
tPHEL
RP#HighRecoverytoWE#
(CE#) Going Low 150 150 150 150 150 150 ns
W2 tELWL /
tWLEL
CE#(WE#)SetuptoWE#
(CE#) Going Low 000000ns
W3 tWLWH /
tELEH
WE#(CE#)PulseWidth 1 45 60 60 70 70 70 ns
W4 tDVWH /
tDVEH
DataSetuptoWE#(CE#)
Going High 2404050606060ns
W5 tAVWH /
tAVEH
Address Setup to WE# (CE#)
Going High 2506060707070ns
W6 tWHEH /
tEHWH
CE# (WE#) Hold Time from
WE# (CE#) High 000000ns
W7 tWHDX /
tEHDX
Data Hold Time from WE#
(CE#) High 2000000ns
W8 tWHAX /
tEHAX
Address Hold Time from WE#
(CE#) High 2000000ns
W9 tWHWL /
tEHEL
WE# (CE#) Pulse Width High 1 25 30 30 30 30 30 ns
W10 tVPWH /
tVPEH
VPP SetuptoWE#(CE#)
Going High 3 200 200 200 200 200 200 ns
W11 tQVVL VPP Hold from Valid SRD 3 0 0 0 0 0 0 ns
W12 tBHWH /
tBHEH
WP# Setup to WE# (CE#)
Going High 3000000ns
W13 tQVBL WP# Hold from Valid SRD 3 0 0 0 0 0 0 ns
W14 tWHGL WE# High to OE# Going Low 3 30 30 30 30 30 30 ns
28F800C3, 28F160C3, 28F320C3, 28F640C3
46 Datasheet
AC Characteristics—Write Operations, continued
#Sym Parameter
Density 64 Mbit
Unit
Product 70 ns 80 ns
3.0 V 3.6 V
2.7V–3.6V 70 70
Note Min Min
W1 tPHWL /
tPHEL
RP# High Recovery to WE# (CE#) Going Low 150 150 ns
W2 tELWL /
tWLEL
CE# (WE#) Setup to WE# (CE#) Going Low 0 0 ns
W3 tWLWH /
tELEH
WE#(CE#)PulseWidth 1 45 60 ns
W4 tDVWH /
tDVEH
Data Setup to WE# (CE#) Going High 2 40 40 ns
W5 tAVW H /
tAVEH
Address Setup to WE# (CE#) Going High 2 50 60 ns
W6 tWHEH /
tEHWH
CE# (WE#) Hold Time from WE# (CE#) High 0 0 ns
W7 tWHDX /
tEHDX
Data Hold Time from WE# (CE#) High 2 0 0 ns
W8 tWHAX /
tEHAX
Address Hold Time from WE# (CE#) High 2 0 0 ns
W9 tWHWL /
tEHEL
WE# (CE#) Pulse Width High 1 25 30 ns
W10 tVPWH /
tVPEH
VPP Setup to WE# (CE#) Going High 3 200 200 ns
W11 tQVVL VPP Hold from Valid SRD 3 0 0 ns
W12 tBHWH /
tBHEH
WP# Setup to WE# (CE#) Going High 3 0 0 ns
W13 tQVBL WP# Hold from Valid SRD 3 0 0 ns
W14 tWHGL WE#HightoOE#GoingLow 3 30 30 ns
NOTES:
1. Write pulse width (tWP) is defined from CE# or WE# going low (whichever goes low last) to CE# or WE#
going high (whichever goes high first). Hence, tWP =t
WLWH =t
ELEH =t
WLEH =t
ELWH. Similarly, write pulse
widthhigh(t
WPH) is defined from CE# or WE# going high (whichever goes high first) to CE# or WE# going
low (whichever goes low first). Hence, tWPH =t
WHWL =t
EHEL =t
WHEL =t
EHWL.
2. Refer to Table 5, “Command Bus Operations” on page 23 for valid AIN or DIN.
3. Sampled, but not 100% tested.
4. VCCMax = 3.3 V for 0.25µm 32-Mbit devices.
5. Write timing characteristics during erase suspend are the same as during Write-only operations.
6. See Figure 7, “Input/Output Reference Waveform” on page 37 for timing measurements and maximum
allowable input slew rate.
7. See Figure 9, “AC Waveform: Read Operations” on page 42.
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 47
4.7 Erase and Program Timings
Symbol Parameter
VPP 1.65 V–3.6 V 11.4 V–12.6 V
Unit
Note Typ(1) Max Typ(1) Max
tBWPB
4-KW Parameter Block
Word Program Time 2, 3 0.10 0.30 0.03 0.12 s
tBWMB
32-KW Main Block
Word Program Time 2, 3 0.8 2.4 0.24 1 s
tWHQV1 /t
EHQV1
Word Program Time for 0.13
and0.18MicronProduct 2, 3 12 200 8 185 µs
Word Program Time for 0.25
Micron Product 2, 3 22 200 8 185 µs
tWHQV2 /t
EHQV2
4-KW Parameter Block
Erase Time 2, 3 0.5 4 0.4 4 s
tWHQV3 /t
EHQV3
32-KW Main Block
Erase Time 2, 3 1 5 0.6 5 s
tWHRH1 /t
EHRH1 Program Suspend Latency 3 5 10 5 10 µs
tWHRH2 /t
EHRH2 Erase Suspend Latency 3 5 20 5 20 µs
NOTES:
1. Typical values measured at TA= +25 °C and nominal voltages.
2. Excludes external system-level overhead.
3. Sampled, but not 100% tested.
28F800C3, 28F160C3, 28F320C3, 28F640C3
48 Datasheet
NOTES:
1. CE# must be toggled low when reading Status Register Data. WE# must be inactive (high) when reading
Status Register Data.
a. VCC Power-Up and Standby.
b. Write Program or Erase Setup Command.
c. Write Valid Address and Data (for Program) or Erase Confirm Command.
d. Automated Program or Erase Delay.
e. Read Status Register Data (SRD): reflects completed Program/Erase operation.
f. WriteReadArrayCommand.
Figure 10. AC Waveform: Program and Erase Operations
A
IN
A
IN
AB C D E F
W11
D
IN
W10
Valid
SRD
D
IN
D
IN
W7
W3
W4
High Z
W2
W9
W6
W5 W8
V
IH
V
IL
ADDRESSES [A]
V
IH
V
IL
CE# (WE#) [E(W)]
V
IH
V
IL
OE# [G]
V
IH
V
IL
WE# (CE) [W(E)]
V
IH
V
IL
DATA [D/Q]
V
IH
V
IL
WP#
V
PPH
1
V
IL
V
PP
[V]
V
PPH
2
V
IH
V
IL
RP# [P]
(Note 1)
(Note 1)
W13W12
W1
V
PPLK
W14
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 49
4.8 Reset Operations
Figure 11. AC Waveform: Reset Operations
IH
V
IL
V
RP# (P)
PLPH
t
IH
V
IL
V
RP# (P)
PLPH
t
(A) Reset during Read Mode
Abort
Complete PHQV
t
PHWL
t
PHEL
t
PHQV
t
PHWL
t
PHEL
t
(B) Reset during Program or Block Erase, <
PLPH
tPLR
H
t
PLRH
t
IH
V
IL
V
RP# (P)
PLPH
t
Abort
Complete PHQV
t
PHWL
t
PHEL
t
PLRH
t
Deep
Power-
Down
(C) Reset Program or Block Erase, >
PLPH
tPLRH
t
Table 13. Reset Specifications
Symbol Parameter Notes
VCC 2.7V–3.6V
Unit
Min Max
tPLPH
RP# Low to Reset during Read
(If RP# is tied to VCC, this specification is not
applicable)
2,4 100 ns
tPLRH1 RP# Low to Reset during Block Erase 3,4 22 µs
tPLRH2 RP# Low to Reset during Program 3,4 12 µs
NOTES:
1. If tPLPH is < 100 ns the device may still reset but this is not guaranteed.
2. If RP# is asserted while a Block Erase or Word Program operation is not executing, the reset will complete
within 100 ns.
3. Sampled, but not 100% tested.
4. See Section 4.1.4 for a full description of these conditions.
28F800C3, 28F160C3, 28F320C3, 28F640C3
50 Datasheet
Appendix A WSM Current/Next States, Sheet 1 of 2
Command Input (and Next State)
Current State SR.
7
Data
When
Read
Read
Array
(FFH)
Program
Setup (10/
40H)
Erase
Setup
(20H)
Erase
Confirm
(D0H)
Prog/Ers
Suspend
(B0H)
Prog/Ers
Resume
(D0)
Read
Status
(70H)
Clear
Status
(50H)
Read Array “1 Array Read Array Prog. Setup Ers. Setup Read Array Read Sts. Read Array
Read Status “1” Status Read Array Prog. Setup Ers. Setup Read Array Read Sts. Read Array
Read Config. “1” Config Read Array Prog. Setup Ers. Setup Read Array Read Sts. Read Array
Read Query “1” CFI Read Array Prog. Setup Ers. Setup Read Array Read Sts. Read Array
Lock Setup “1” Status Lock Command Error Lock
(Done)
Lock
Cmd. Error
Lock
(Done) Lock Cmd. Error
Lock Cmd. Error “1” Status Read Array Prog. Setup Ers. Setup Read Array Read Sts. Read Array
Lock Oper. (Done) “1” Status Read Array Prog. Setup Ers. Setup Read Array Read Sts. Read Array
Prot. Prog. Setup “1” Status Protection Register Program
Prot. Prog.
(Not Done) “0” Status Protection Register Program (Not Done)
Prot. Prog. (Done) “1” Status Read Array Prog. Setup Ers. Setup Read Array Read Sts. Read Array
Prog. Setup “1” Status Program
Program (Not
Done) “0” Status Program (Not Done) Prog. Sus.
Status Program (Not Done)
Prog. Susp. Status “1 Status Prog. Sus.
Read Array
Program Suspend
Read Array
Prog. (Not
Done)
Prog. Sus.
Rd. Array
Program
(Not Done)
Prog. Sus.
Status
Prog. Sus.
Rd. Array
Prog. Susp. Read
Array “1” Array Prog. Sus.
Read Array
Program Suspend
Read Array
Prog. (Not
Done)
Prog. Sus.
Rd. Array
Program
(Not Done)
Prog. Sus.
Status
Prog. Sus.
Rd. Array
Prog. Susp. Read
Config “1” Config Prog. Sus.
Read Array
Program Suspend
Read Array
Prog. (Not
Done)
Prog. Sus.
Rd. Array
Program
(Not Done)
Prog. Sus.
Status
Prog. Sus.
Rd. Array
Prog. Susp. Read
Query “1” CFI Prog. Sus.
Read Array
Program Suspend
Read Array
Prog. (Not
Done)
Prog. Sus.
Rd. Array
Program
(Not Done)
Prog. Sus.
Status
Prog. Sus.
Rd. Array
Program (Done) “1” Status Read Array Prog. Setup Ers. Setup Read Array Read
Status Read Array
Erase Setup “1” Status Erase Command Error
Erase
(Not
Done)
Erase Cmd.
Error
Erase
(Not Done) Erase Command Error
Erase Cmd. Error “1” Status Read Array Prog. Setup Ers. Setup Read Array Read
Status Read Array
Erase (Not Done) 0” Status Erase (Not Done) Erase Sus.
Status Erase (Not Done)
Ers. Susp. Status “1” Status Erase Sus.
Read Array Prog. Setup Ers. Sus.
Rd. Array Erase Ers. Sus.
Rd. Array Erase Erase Sus.
Status
Ers. Sus.
Rd. Array
Erase Susp. Array “1” Array Erase Sus.
Read Array Prog. Setup Ers. Sus.
Rd. Array Erase Ers. Sus.
Rd. Array Erase Erase Sus.
Status
Ers. Sus.
Rd. Array
Ers. Susp. Read
Config “1” Config Erase Sus.
Read Array Prog. Setup Ers. Sus.
Rd. Array Erase Ers. Sus.
Rd. Array Erase Erase Sus.
Status
Ers. Sus.
Rd. Array
Ers. Susp. Read
Query “1” CFI Erase Sus.
Read Array Prog. Setup Ers. Sus.
Rd. Array Erase Ers. Sus.
Rd. Array Erase Erase Sus.
Status
Ers. Sus.
Rd. Array
Erase (Done) “1” Status Read Array Prog. Setup Ers. Setup Read Array Read Sts. Read Array
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 51
Appendix A: WSM Current/Next States, Sheet 2 of 2
CommandInput(andNextState)
Current State Read Config
(90H)
Read Query
(98H)
Lock Setup
(60H) Prot. Prog.
Setup (C0H)
Lock Confirm
(01H)
Lock Down
Confirm
(2FH)
Unlock Confirm
(D0H)
Read Array Read Config. Read Query Lock Setup Prot. Prog. Setup Read Array
Read Status Read Config. Read Query Lock Setup Prot. Prog. Setup Read Array
Read Config. Read Config. Read Query Lock Setup Prot. Prog. Setup Read Array
Read Query Read Config. Read Query Lock Setup Prot. Prog. Setup Read Array
Lock Setup Locking Command Error Lock Operation (Done)
Lock Cmd. Error Read Config. Read Query Lock Setup Prot. Prog. Setup Read Array
Lock Oper.
(Done) Read Config. Read Query Lock Setup Prot. Prog. Setup Read Array
Prot. Prog. Setup Protection Register Program
Prot. Prog.
(Not Done) Protection Register Program (Not Done)
Prot. Prog.
(Done) Read Config. Read Query Lock Setup Prot. Prog. Setup Read Array
Prog. Setup Program
Program
(Not Done) Program (Not Done)
Prog. Susp.
Status
Prog. Susp.
Read Config.
Prog. Susp.
Read Query Program Suspend Read Array Program
(Not Done)
Prog. Susp.
Read Array
Prog. Susp.
Read Config.
Prog. Susp.
Read Query Program Suspend Read Array Program
(Not Done)
Prog. Susp.
Read Config.
Prog. Susp.
Read Config.
Prog. Susp.
Read Query Program Suspend Read Array Program
(Not Done)
Prog. Susp.
Read Query.
Prog. Susp.
Read Config.
Prog. Susp.
Read Query Program Suspend Read Array Program
(Not Done)
Program
(Done) Read Config. Read Query Lock Setup Prot. Prog. Setup Read Array
Erase
Setup Erase Command Error Erase
(Not Done)
Erase Cmd.
Error Read Config. Read Query Lock Setup Prot. Prog. Setup Read Array
Erase
(Not Done) Erase (Not Done)
Erase Susp.
Status
Ers. Susp. Read
Config.
Erase Suspend
Read Query Lock Setup Erase Suspend Read Array Erase
(Not Done)
Erase Suspend
Array
Ers. Susp. Read
Config.
Erase Suspend
Read Query Lock Setup Erase Suspend Read Array Erase
(Not Done)
Eras Sus. Read
Config
Erase Suspend
Read Config.
Erase Suspend
Read Query Lock Setup Erase Suspend Read Array Erase
(Not Done)
Eras Sus. Read
Query
Erase Suspend
Read Config.
Erase Suspend
Read Query Lock Setup Erase Suspend Read Array Erase
(Not Done)
Ers.(Done) Read Config. Read Query Lock Setup Prot. Prog. Setup Read Array
28F800C3, 28F160C3, 28F320C3, 28F640C3
52 Datasheet
Appendix B Program/Erase Flowcharts
Figure 12. Automated Word Programming Flowchart
Start
Write 40H
Program Address/Data
Read Status Register
SR.7 = 1?
Full Status
Check if Desired
Program Complete
Read Status Register
Data (See Above)
V
PP
Range Error
Programming Error
Attempted Program to
Locked Block - Aborted
Program Successful
SR.3 =
SR.4 =
SR.1 =
FULL STATUS CHECK PROCEDURE
Bus Operation
Write
Write
Standby
Repeat for subsequent programming operations.
SR Full Status Check can be done after each program or after a sequence of
program operations.
Write FFH after the last program operation to reset device to read array mode.
Bus Operation
Standby
Standby
SR.3 MUST be cleared, if set during a program attempt, before further
attempts are allowed by the W rite State Machine.
SR.1, SR.3 and SR.4 are only cleared by the Clear Staus Register Command,
in cases where multiple bytes are programmed before full status is checked.
If an error is detected, clear the status register before attempting retry or other
error recovery.
No
Yes
1
0
1
0
1
0
Command
Program Setup
Program
Comments
Data = 40H
Data=DatatoProgram
Addr = Location to Program
Check SR.7
1 = WSM Ready
0=WSMBusy
Command Comments
Check SR.3
1=V
PP
Low Detect
Check SR.1
1 = Attempted Program to
Locked Block - Program
Aborted
Read
Status Register Data Toggle
CE# or OE# to Update Status
Register Data
Standby Check SR.4
1=V
PP
Program Error
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 53
Figure 13. Program Suspend/Resume Flowchart
Start
Write B0H
Read Status Register
No
Comments
Data = B0H
Addr = X
Data = FFH
Addr = X
SR.7 =
SR.2 =
1
Write FFH
Read Array Data
Program Completed
Done
Reading
Yes
Write FFHWrite D0H
Program Resumed Read Array Data
0
1
Read array data from block
other than the one being
programmed.
Status Register Data Toggle
CE# or OE# to Update Status
Register Data
Addr = X
Check SR.7
1 = WSM Ready
0=WSMBusy
Check SR.2
1 = Program Suspended
0 = Program Completed
Data = D0H
Addr = X
Bus
Operation Command
0
Write 70H
Status Register Data Toggle
CE# or OE# to Update Status
Register Data
Addr = X
Write
Write
Write
Read
Read
Standby
Standby
Write
Data=70H
Addr=X
Command
Program
Suspend
Read Status
Read Array
Program
Resume
28F800C3, 28F160C3, 28F320C3, 28F640C3
54 Datasheet
Figure 14. Automated Block Erase Flowchart
Start
Write 20H
Write D0H and
Block Address
Read Status Register
SR.7 =
Full Status
Check if Desired
Block Erase Complete
FULL STATUS CHECK PROCEDURE
Bus Operation
Write
Write
Standby
Repeat for subsequent block erasures.
Full Status Check can be done after each block erase or after a sequence of
block erasures.
Write FFH after the last write operation to reset device to read array mode.
Bus Operation
Standby
SR. 1 and 3 MUST be cleared, if set during an erase attempt, before further
attempts are allowed by the Write State Machine.
SR.1, 3, 4, 5 are only cleared by the Clear Staus Register Command, in cases
where multiple bytes are erased before full status is checked.
If an error is detected, clear the status register before attempting retry or other
error recovery.
No Yes
Suspend Erase
Suspend
Erase Loop
1
0
Standby
Command
Erase Setup
Erase Confirm
Comments
Data = 20H
Addr = Within Block to Be
Erased
Data = D0H
Addr = Within Block to Be
Erased
Check SR.7
1=WSMReady
0 = WSM Busy
Command Comments
Check SR.3
1=V
PP
Low Detect
Check SR.4,5
Both1=CommandSequence
Error
Read Status Register
Data (See Above)
V
PP
Range Error
Command Sequence
Error
Block Erase
Successful
SR.3 =
SR.4,5 =
1
0
1
0
Block Erase ErrorSR.5 =
1
0
Attempted Erase of
Locked Block - Aborted
SR.1 =
1
0
Read
Status Register Data Toggle
CE# or OE# to Update Status
Register Data
Standby Check SR.5
1=BlockErase Error
Standby
Check SR.1
1 = Attempted Erase of
Locked Block - Erase Aborted
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 55
Figure 15. Erase Suspend/Resume Flowchart
Start
Write B0H
Read Status Register
No
Comments
Data = B0H
Addr = X
Data = FFH
Addr = X
SR.7 =
SR.6 =
1
Write FFH
Read Array Data
Erase Completed
Done
Reading
Yes
Write FFHWrite D0H
Erase Resumed Read Array Data
0
1
Read array data from block
other than the one being
erased.
Status Register Data Toggle
CE# or OE# to Update Status
Register Data
Addr = X
Check SR.7
1 = WSM Ready
0=WSMBusy
Check SR.6
1 = Erase Suspended
0 = Erase Completed
Data = D0H
Addr = X
Bus
Operation
Write
Standby
Write
Read
Standby
Read
Command
0
Write 70H
Status Register Data Toggle
CE# or OE# to Update Status
Register Data
Addr = X
Write
Write
Data=70H
Addr=X
Command
Erase Suspend
Read Status
Read Array
Erase Resume
28F800C3, 28F160C3, 28F320C3, 28F640C3
56 Datasheet
Figure 16. Locking Operations Flowchart
Start
Write 60H
(Configuration Setup)
No
Comments
Data = 60H
Addr = X
Write 90H
(Read Configuration)
Read Block Lock Status
Locking
Change
Confirmed?
Locking Change
Complete
Bus
Operation
Write
Command
Write
01H, D0H, or 2FH
Write
Write
Data= 01H (Lock Block)
D0H (Unlock Block)
2FH (Lockdown Block)
Addr=Within block to lock
Command
Config. Setup
Lock, Unlock,
or Lockdown
Data = 90H
Addr = X
Write
(Optional)
Read
Configuration
Block Lock Status Data
Addr = Second addr of block
Read
(Optional)
Block Lock
Status
Confirm Locking Change on
DQ
1
,DQ
0
. (See Block Locking
State Table for valid
combinations.)
Standby
(Optional)
Optional
Write FFh
(Read Array)
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 57
Figure 17. Protection Register Programming Flowchart
Start
Write C0H
(Protection Reg.
Program Setup)
Write Protect. Register
Address/Data
Read Status Register
SR.7 = 1?
Full Status
Check if Desired
Program Complete
Read Status Register
Data (See Above)
V
PP
Range Error
Protection Register
Programming Error
Attempted Program to
Locked Register -
Aborted
Program Successful
SR.3, SR.4 =
SR.1, SR.4 =
SR.1, SR.4 =
FULL STATUS CHECK PROCEDURE
Bus Operation
Write
Write
Standby
Protection Program operations can only be addressed within the protection
register address space. Addresses outside the defined space will return an
error.
Repeat for subsequent programming operations.
SR Full Status Check can be done after each program or after a sequence of
program operations.
Write FFH after the last program operation to reset device to read array mode.
Bus Operation
Standby
Standby
SR.3 MUST be cleared, if set during a program attempt, before further
attempts are allowed by the Write State Machine.
SR.1, SR.3 and SR.4 are only cleared by the Clear Staus Register Command,
in cases of multiple protection register program operations before full status is
checked.
If an error is detected, clear the status register before attempting retry or other
error recovery.
No
Yes
1, 1
0,1
1,1
Command
Protection Program
Setup
Protection Program
Comments
Data = C0H
Data=DatatoProgram
Addr = Location to Program
Check SR.7
1 = WSM Ready
0=WSMBusy
Command Comments
SR.1 SR.3 SR.4
0 11V
PP
Low
0 01Prot.Reg.
Prog. Error
1 01Register
Locked:
Aborted
Read
Status Register Data Toggle
CE# or OE# to Update Status
Register Data
Standby
28F800C3, 28F160C3, 28F320C3, 28F640C3
58 Datasheet
Appendix C Common Flash Interface Query Structure
This appendix defines the data structure or “database” returned by the Common Flash Interface
(CFI) Query command. System software should parse this structure to gain critical information
such as block size, density, x8/x16, and electrical specifications. Once this information has been
obtained, the software will know which command sets to use to enable flash writes, block erases,
and otherwise control the flash component. The Query is part of an overall specification for
multiple command set and control-interface descriptions called Common Flash Interface, or CFI.
C.1 Query Structure Output
The Query “database” allows system software to gain information for controlling the flash
component. This section describes the device’s CFI-compliant interface that allows the host system
to access Query data.
Query data are always presented on the lowest order data outputs (DQ0-7)only.Thenumerical
offset value is the address relative to the maximum bus width supported by the device. On this
family of devices, the Query table device starting address is a 10h, which is a word address for x16
devices.
For a word-wide (x16) device, the first two bytes of the Query structure, “Q” and “R” in ASCII,
appear on the low byte at word addresses 10h and 11h. This CFI-compliant device outputs 00H
data on upper bytes. Thus, the device outputs ASCII “Q in the low byte (DQ0-7) and 00h in the
high byte (DQ8-15).
At Query addresses containing two or more bytes of information, the least significant data byte is
presented at the lower address, and the most significant data byte is presented at the higher address.
In all of the following tables, addresses and data are represented in hexadecimal notation, so the
“h” suffix has been dropped. In addition, since the upper byte of word-wide devices is always
“00h,” the leading “00” has been dropped from the table notation and only the lower byte value is
shown. Any x16 device outputs can be assumed to have 00h on the upper byte in this mode.
Table 14. Summary of Query Structure Output As a Function of Device and Mode
Device Hex
Offset Code ASCII
Value
Device Addresses
10: 51 “Q”
11: 52 R
12: 59 “Y”
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 59
C.2 Query Structure Overview
The Query command causes the flash component to display the Common Flash Interface (CFI)
Query structure or “database.” The structure sub-sections and address locations are summarized
below.
NOTES:
1. Refer to the Query Structure Output section and offset 28h for the detailed definition of offset address as a
function of device bus width and mode.
2. BA = The beginning location of a Block Address (e.g., 08000h is the beginning location of block 1 when the
block size is 32 Kword).
3. Offset 15 defines “P which points to the Primary Intel-specific Extended Query Table.
Table 15. Example of Query Structure Output of x16 and x8 Devices
Word Addressing Byte Addressing
Offset Hex Code Value Offset Hex Code Value
A15–A0D15–D0A7–A0D7–D0
0010h 0051 “Q 10h 51 “Q”
0011h 0052 R” 11h 52 “R”
0012h 0059 “Y 12h 59 Y”
0013h P_IDLO PrVendor 13h P_IDLO PrVendor
0014h P_IDHI ID # 14h P_IDLO ID #
0015h PLO PrVendor 15h P_IDHI ID #
0016h PHI TblAdr 16h ... ...
0017h A_IDLO AltVendor 17h
0018h A_IDHI ID # 18h
... ... ... ...
Table 16. Query Structure(1)
Offset Sub-Section Name Description
00h Manufacturer Code
01h Device Code
(BA+2)h(2) Block Status Register Block-Specific Information
04-0Fh Reserved Reserved for Vendor-Specific Information
10h CFI Query Identification String Command Set ID and Vendor Data Offset
1Bh System Interface Information Device Timing and Voltage Information
27h Device Geometry Definition Flash Device Layout
P(3) Primary Intel-Specific Extended Query Table Vendor-Defined Additional Information
Specific to the Primary Vendor Algorithm
28F800C3, 28F160C3, 28F320C3, 28F640C3
60 Datasheet
C.3 BlockLockStatusRegister
The block-status register indicates whether an Erase operation completed successfully or whether a
given block is locked or can be accessed for flash Program/Erase operations.
Block Erase Status (BSR.1) allows system software to determine the success of the last Block
Erase operation. BSR.1 can be used just after power-up to verify that the VCC supply was not
accidentally removed during an Erase operation. This bit is reset only by issuing another Erase
operation to the block. The block-status register is accessed from word address 02h within each
block.
C.4 CFI Query Identification String
The Identification String provides verification that the component supports the Common Flash
Interface specification. It also indicates the specification version and supported vendor-specified
command set(s).
Table17. BlockStatusRegister
Offset Length Description Add. Value
(BA+2)h(1) 1 Block Lock Status Register BA+2: --00 or --01
BSR.0 Block Lock Status
0 = Unlocked
1 = Locked
BA+2: (bit 0): 0 or 1
BSR.1 Block Lock-Down Status
0 = Not locked down
1=Lockeddown
BA+2: (bit 1): 0 or 1
BSR 2–7: Reserved for future use BA+2: (bit 2–7): 0
NOTE: BA = The beginning location of a Block Address (i.e., 008000h is the beginning location of block 1 in
word mode.)
Table 18. CFI Identification
Offset Length Description Add. Hex Code Value
10h 3 Query-unique ASCII string “QRY“
10
11:
12:
--51
--52
--59
“Q”
“R”
“Y”
13h 2 Primary vendor command set and control interface ID code
16-bit ID code for vendor-specified algorithms
13:
14:
--03
--00
15h 2 Extended Query Table primary algorithm address 15:
16:
--35
--00
17h 2 Alternate vendor command set and control interface ID code
0000h means no second vendor-specified algorithm exists
17:
18:
--00
--00
19h 2 Secondary algorithm Extended Query Table address
0000h means none exists
19:
1A:
--00
--00
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 61
C.5 System Interface Information
Table 19. System Interface Information
Offset Length Description Add. Hex Code Value
1Bh 1
VCC logic supply minimum program/erase voltage
bits 0–3 BCD 100 mV
bits 4–7 BCD volts
1B: --27 2.7 V
1Ch 1
VCC logic supply maximum program/erase voltage
bits 0–3 BCD 100 mV
bits 4–7 BCD volts
1C: --36 3.6 V
1Dh 1
VPP [programming] supply minimum program/erase voltage
bits 0–3 BCD 100 mV
bits 4–7 HEX volts
1D: --B4 11.4 V
1Eh 1
VPP [programming] supply maximum program/erase voltage
bits 0–3 BCD 100 mV
bits 4–7 HEX volts
1E: --C6 12.6 V
1Fh 1 “n” such that typical single word program time-out =2nµs 1F: --05 32 µs
20h 1 “n” such that typical max. buffer write time-out = 2nµs 20: --00 NA
21h 1 “n” such that typical block erase time-out = 2nms 21: --0A 1 s
22h 1 “n” such that typical full chip erase time-out = 2nms 22: --00 NA
23h 1 “n” such that maximum word program time-out = 2ntimes typical 23: --04 512µs
24h 1 “n” such that maximum buffer write time-out = 2ntimes typical 24: --00 NA
25h 1 “n” such that maximum block erase time-out = 2ntimes typical 25: --03 8s
26h 1 “n” such that maximum chip erase time-out = 2ntimes typical 26: --00 NA
28F800C3, 28F160C3, 28F320C3, 28F640C3
62 Datasheet
C.6 Device Geometry Definition
Table 20. Device Geometry Definition
Offset Length Description Code
See table below
27h 1 “n such that device size = 2nin number of bytes 27:
28h 2
Flash device interface:
x8 async x16 async x8/x16 async 28: --01 x16
28:00,29:00 28:01,29:00 28:02,29:00 29: --00
2Ah 2 “n such that maximum number of bytes in write buffer = 2n2A:
2B:
--00
--00 0
2Ch 1
Number of erase block regions within device:
1. x = 0 means no erase blocking; the device erases in “bulk”
2. x specifies the number of device or partition regions
with one or more contiguous same-size erase blocks.
3. Symmetrically blocked partitions have one blocking region
4. Partition size = (total blocks) x (individual block size)
2C: --02 2
2Dh 4
Erase Block Region 1 Information
bits 0–15 = y, y+1 = number of identical-size erase blocks
bits 16–31 = z, region erase block(s) size are z x 256 bytes
2D:
2E:
2F:
30:
31h 4
Erase Block Region 2 Information
bits 0–15 = y, y+1 = number of identical-size erase blocks
bits 16–31 = z, region erase block(s) size are z x 256 bytes
31:
32:
33:
34:
Device Geometry Definition
Address 8Mbit 16Mbit 32Mbit 64Mbit
–B –T –B T –B –T –B –T
27: --14 --14 --15 --15 --16 --16 --17 --17
28: --01 --01 --01 --01 --01 --01 --01 --01
29: --00 --00 --00 --00 --00 --00 --00 --00
2A: --00 --00 --00 --00 --00 --00 --00 --00
2B: --00 --00 --00 --00 --00 --00 --00 --00
2C: --02 --02 --02 --02 --02 --02 --02 --02
2D: --07 --0E --07 --1E --07 --3E --07 --7E
2E: --00 --00 --00 --00 --00 --00 --00 --00
2F: --20 --00 --20 --00 --20 --00 --20 --00
30: --00 --01 --00 --01 --00 --01 --00 --01
31: --0E --07 --1E --07 --3E --07 --7E --07
32: --00 --00 --00 --00 --00 --00 --00 --00
33: --00 --20 --00 --20 --00 --20 --00 --20
34: --01 --00 --01 --00 --01 --00 --01 --00
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 63
C.7 Intel-Specific Extended Query Table
Certain flash features and commands are optional. The Intel-Specific Extended Query table
specifies this and other similar types of information.
Table 21. Primary-Vendor Specific Extended Query
Offset(1)
P=35h Length Description
(Optional Flash Features and Commands) Address Hex Code Value
(P+0)h
(P+1)h
(P+2)h
3Primary extended query table
Unique ASCII string PRI”
35:
36:
37:
--50
--52
--49
“P”
“R”
“I”
(P+3)h 1 Major version number, ASCII 38: --31 “1”
(P+4)h 1 Minor version number, ASCII 39: --30 “0”
(P+5)h
(P+6)h
(P+7)h
(P+8)h
4
Optional feature and command support (1=yes,
0=no)
bits 9–31 are reserved; undefined bits are “0.” If bit
31 is “1” then another 31 bit field of optional
features follows at the end of the bit-30 field.
3A:
3B:
3C:
3D:
--66
--00
--00
--00
bit 0 Chip erase supported
bit 1 Suspend erase supported
bit 2 Suspend program supported
bit 3 Legacy lock/unlock supported
bit 4 Queued erase supported
bit 5 Instant individual block locking supported
bit 6 Protection bits supported
bit 7 Page mode read supported
bit 8 Synchronous read supported
bit 0 = 0
bit 1 = 1
bit 2 = 1
bit 3 = 0
bit 4 = 0
bit 5 = 1
bit 6 = 1
bit 7 = 0
bit 8 = 0
No
Yes
Yes
No
No
Yes
Yes
No
No
(P+9)h 1
Supported functions after suspend: Read Array,
Status, Query
Other supported operations are:
bits 1–7 reserved; undefined bits are “0”
3E: --01
bit 0 Program supported after erase suspend bit 0 = 1 Yes
(P+A)h
(P+B)h 2
Block status register mask
bits 2–15 are Reserved; undefined bits are 0”
bit 0 Block Lock-Bit Status Register active
bit 1 Block Lock-Down Bit Status active
3F: --03
40: --00
bit 0 = 1 Yes
bit 1 = 1 Yes
(P+C)h 1
VCC logic supply highest performance program/
erase voltage
bits 0–3 BCD value in 100 mV
bits 4–7 BCD value in volts
41: --33 3.3 V
(P+D)h 1
VPP optimum program/erase supply voltage
bits 0–3 BCD value in 100 mV
bits 4–7 HEX value in volts
42: --C0 12.0 V
28F800C3, 28F160C3, 28F320C3, 28F640C3
64 Datasheet
Table 22. Protection Register Information
Offset(1)
P=35h Length Description
(Optional Flash Features and Commands) Address Hex
Code Value
(P+E)h 1 Number of Protection register fields in JEDEC ID space.
“00h, indicates that 256 protection bytes are available 43: --01 01
(P+F)h
(P+10)h
(P+11)h
4
44:
45:
46:
--80
--00
--03
80h
00h
8byte
Protection Field 1: Protection Description
(P+12)h
This field describes user-available One Time Programmable (OTP)
Protection register bytes. Some are pre-programmed with device-
unique serial numbers. Others are user programmable. Bits 0–15
point to the Protection register Lock byte, the section’s first byte.
The following bytes are factory pre-programmed and user-
programmable.
bits 0–7 = Lock/bytes JEDEC-plane physical low address
bits 8–15 = Lock/bytes JEDEC -plane physical high address
bits 16–23 = “n such that 2n= factory pre-programmed bytes
bits 24–31 = “n such that 2n= user programmable bytes
47: --03 8 byte
(P+13)h Reserved for future use 48:
NOTE: The variable P is a pointer which is defined at CFI offset 15h.
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 65
Appendix D Architecture Block Diagram
Output
Multiplexer
4-KWord
Parameter Block
32-KWord
Main Block
32-KWord
Main Block
4-KWord
Parameter Block
Y-Gating/Sensing Write State
Machine
Program/Erase
Voltage Switch
Data
Comparator
Status
Register
Identifier
Register
Data
Register
I/O Logic
Address
Latch
Address
Counter
X-Decoder
Y-Decoder
Power
Reduction
Control
Input Buffer
Output Buffer
GND
V
CC
V
PP
CE#
WE#
OE#
RP#
Command
User
Interface
Input Buffer
A
0
-A
19
DQ
0
-DQ
15
V
CCQ
WP#
28F800C3, 28F160C3, 28F320C3, 28F640C3
66 Datasheet
Appendix E Word-Wide Memory Map Diagrams
8-Mbit Word-Wide Memory Addressing
Top Boot Bottom Boot
Size
(KW) 8Mbit Size
(KW) 8Mbit
4 7F000-7FFFF 32 78000-7FFFF
4 7E000-7EFFF 32 70000-77FFF
4 7D000-7DFFF 32 68000-6FFFF
4 7C000-7CFFF 32 60000-67FFF
4 7B000-7BFFF 32 58000-5FFFF
4 7A000-7AFFF 32 50000-57FFF
4 79000-79FFF 32 48000-4FFFF
4 78000-78FFF 32 40000-47FFF
32 70000-77FFF 32 38000-3FFFF
32 68000-6FFFF 32 30000-37FFF
32 60000-67FFF 32 28000-2FFFF
32 58000-5FFFF 32 20000-27FFF
32 50000-57FFF 32 18000-1FFFF
32 48000-4FFFF 32 10000-17FFF
32 40000-47FFF 32 08000-0FFFF
32 38000-3FFFF 4 07000-07FFF
32 30000-37FFF 4 06000-06FFF
32 28000-2FFFF 4 05000-05FFF
32 20000-27FFF 4 04000-04FFF
32 18000-1FFFF 4 03000-03FFF
32 10000-17FFF 4 02000-02FFF
32 08000-0FFFF 4 01000-01FFF
32 00000-07FFF 4 00000-00FFF
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 67
16-Mbit, 32-Mbit, and 64-Mbit Word-Wide Memory Addressing
Top Boot Bottom Boot
Size
(KW) 16 Mbit 32 Mbit 64 Mbit Size
(KW) 16 Mbit 32 Mbit 64 Mbit
4 FF000-FFFFF 1FF000-1FFFFF 3FF000-3FFFFF 32 3F8000-3FFFFF
4 FE000-FEFFF 1FE000-1FEFFF 3FE000-3FEFFF 32 3F0000-3F7FFF
4 FD000-FDFFF 1FD000-1FDFFF 3FD000-3FDFFF 32 3E8000-3EFFFF
4 FC000-FCFFF 1FC000-1FCFFF 3FC000-3FCFFF 32 3E0000-3E7FFF
4 FB000-FBFFF 1FB000-1FBFFF 3FB000-3FBFFF 32 3D8000-3DFFFF
4 FA000-FAFFF 1FA000-1FAFFF 3FA000-3FAFFF 32 3D0000-3D7FFF
4 F9000-F9FFF 1F9000-1F9FFF 3F9000-3F9FFF 32 3C8000-3CFFFF
4 F8000-F8FFF 1F8000-1F8FFF 3F8000-3F8FFF 32 3C0000-3C7FFF
32 F0000-F7FFF 1F0000-1F7FFF 3F0000-3F7FFF 32 3B8000-3BFFFF
32 E8000-EFFFF 1E8000-1EFFFF 3E8000-3EFFFF 32 3B0000-3B7FFF
32 E0000-E7FFF 1E0000-1E7FFF 3E0000-3E7FFF 32 3A8000-3AFFFF
32 D8000-DFFFF 1D8000-1DFFFF 3D8000-3DFFFF 32 3A0000-3A7FFF
32 D0000-D7FFF 1D0000-1D7FFF 3D0000-3D7FFF 32 398000-39FFFF
32 C8000-CFFFF 1C8000-1CFFFF 3C8000-3CFFFF 32 390000-397FFF
32 C0000-C7FFF 1C0000-1C7FFF 3C0000-3C7FFF 32 388000-38FFFF
32 B8000-BFFFF 1B8000-1BFFFF 3B8000-3BFFFF 32 380000-387FFF
32 B0000-B7FFF 1B0000-1B7FFF 3B0000-3B7FFF 32 378000-37FFFF
32 A8000-AFFFF 1A8000-1AFFFF 3A8000-3AFFFF 32 370000-377FFF
32 A0000-A7FFF 1A0000-1A7FFF 3A0000-3A7FFF 32 368000-36FFFF
32 98000-9FFFF 198000-19FFFF 398000-39FFFF 32 360000-367FFF
32 90000-97FFF 190000-197FFF 390000-397FFF 32 358000-35FFFF
32 88000-8FFFF 188000-18FFFF 388000-38FFFF 32 350000-357FFF
32 80000-87FFF 180000-187FFF 380000-387FFF 32 348000-34FFFF
32 78000-7FFFF 178000-17FFFF 378000-37FFFF 32 340000-347FFF
32 70000-77FFF 170000-177FFF 370000-377FFF 32 338000-33FFFF
32 68000-6FFFF 168000-16FFFF 368000-36FFFF 32 330000-337FFF
32 60000-67FFF 160000-167FFF 360000-367FFF 32 328000-32FFFF
32 58000-5FFFF 158000-15FFFF 358000-35FFFF 32 320000-327FFF
32 50000-57FFF 150000-157FFF 350000-357FFF 32 318000-31FFFF
32 48000-4FFFF 148000-14FFFF 348000-34FFFF 32 310000-317FFF
32 40000-47FFF 140000-147FFF 340000-347FFF 32 308000-30FFFF
32 38000-3FFFF 138000-13FFFF 338000-33FFFF 32 300000-307FFF
32 30000-37FFF 130000-137FFF 330000-337FFF 32 2F8000-2FFFFF
32 28000-2FFFF 128000-12FFFF 328000-32FFFF 32 2F0000-2F7FFF
32 20000-27FFF 120000-127FFF 320000-327FFF 32 2E8000-2EFFFF
32 18000-1FFFF 118000-11FFFF 318000-31FFFF 32 2E0000-2E7FFF
32 10000-17FFF 110000-117FFF 310000-317FFF 32 2D8000-2DFFFF
32 08000-0FFFF 108000-10FFFF 308000-30FFFF 32 2D0000-2D7FFF
32 00000-07FFF 100000-107FFF 300000-307FFF 32 2C8000-2CFFFF
32 0F8000-0FFFFF 2F8000-2FFFFF 32 2C0000-2C7FFF
32 0F0000-0F7FFF 2F0000-2F7FFF 32 2B8000-2BFFFF
32 0E8000-0EFFFF 2E8000-2EFFFF 32 2B0000-2B7FFF
32 0E0000-0E7FFF 2E0000-2E7FFF 32 2A8000-2AFFFF
32 0D8000-0DFFFF 2D8000-2DFFFF 32 2A0000-2A7FFF
32 0D0000-0D7FFF 2D0000-2D7FFF 32 298000-29FFFF
32 0C8000-0CFFFF 2C8000-2CFFFF 32 290000-297FFF
32 0C0000-0C7FFF 2C0000-2C7FFF 32 288000-28FFFF
32 0B8000-0BFFFF 2B8000-2BFFFF 32 280000-287FFF
32 0B0000-0B7FFF 2B0000-2B7FFF 32 278000-27FFFF
32 0A8000-0AFFFF 2A8000-2AFFFF 32 270000-277FFF
This column continues on next page This column continues on next page
28F800C3, 28F160C3, 28F320C3, 28F640C3
68 Datasheet
16-Mbit, 32-Mbit, and 64-Mbit Word-Wide Memory Addressing
Top Boot Bottom Boot
Size
(KW) 16 Mbit 32 Mbit 64 Mbit Size
(KW) 16 Mbit 32 Mbit 64 Mbit
32 0A0000-0A7FFF 2A0000-2A7FFF 32 268000-26FFFF
32 098000-09FFFF 298000-29FFFF 32 260000-267FFF
32 090000-097FFF 290000-297FFF 32 258000-25FFFF
32 088000-08FFFF 288000-28FFFF 32 250000-257FFF
32 080000-087FFF 280000-287FFF 32 248000-24FFFF
32 078000-07FFFF 278000-27FFFF 32 240000-247FFF
32 070000-077FFF 270000-277FFF 32 238000-23FFFF
32 068000-06FFFF 268000-26FFFF 32 230000-237FFF
32 060000-067FFF 260000-267FFF 32 228000-22FFFF
32 058000-05FFFF 258000-25FFFF 32 220000-227FFF
32 050000-057FFF 250000-257FFF 32 218000-21FFFF
32 048000-04FFFF 248000-24FFFF 32 210000-217FFF
32 040000-047FFF 240000-247FFF 32 208000-20FFFF
32 038000-03FFFF 238000-23FFFF 32 200000-207FFF
32 030000-037FFF 230000-237FFF 32 1F8000-1FFFFF 1F8000-1FFFFF
32 028000-02FFFF 228000-22FFFF 32 1F0000-1F7FFF 1F0000-1F7FFF
32 020000-027FFF 220000-227FFF 32 1E8000-1EFFFF 1E8000-1EFFFF
32 018000-01FFFF 218000-21FFFF 32 1E0000-1E7FFF 1E0000-1E7FFF
32 010000-017FFF 210000-217FFF 32 1D8000-1DFFFF 1D8000-1DFFFF
32 008000-00FFFF 208000-21FFFF 32 1D0000-1D7FFF 1D0000-1D7FFF
32 000000-007FFF 200000-207FFF 32 1C8000-1CFFFF 1C8000-1CFFFF
32 1F8000-1FFFFF 32 1C0000-1C7FFF 1C0000-1C7FFF
32 1F0000-1F7FFF 32 1B8000-1BFFFF 1B8000-1BFFFF
32 1E8000-1EFFFF 32 1B0000-1B7FFF 1B0000-1B7FFF
32 1E0000-1E7FFF 32 1A8000-1AFFFF 1A8000-1AFFFF
32 1D8000-1DFFFF 32 1A0000-1A7FFF 1A0000-1A7FFF
32 1D0000-1D7FFF 32 198000-19FFFF 198000-19FFFF
32 1C8000-1CFFFF 32 190000-197FFF 190000-197FFF
32 1C0000-1C7FFF 32 188000-18FFFF 188000-18FFFF
32 1B8000-1BFFFF 32 180000-187FFF 180000-187FFF
32 1B0000-1B7FFF 32 178000-17FFFF 178000-17FFFF
32 1A8000-1AFFFF 32 170000-177FFF 170000-177FFF
32 1A0000-1A7FFF 32 168000-16FFFF 168000-16FFFF
32 198000-19FFFF 32 160000-167FFF 160000-167FFF
32 190000-197FFF 32 158000-15FFFF 158000-15FFFF
32 188000-18FFFF 32 150000-157FFF 150000-157FFF
32 180000-187FFF 32 148000-14FFFF 148000-14FFFF
32 178000-17FFFF 32 140000-147FFF 140000-147FFF
32 170000-177FFF 32 138000-13FFFF 138000-13FFFF
32 168000-16FFFF 32 130000-137FFF 130000-137FFF
32 160000-167FFF 32 128000-12FFFF 128000-12FFFF
32 158000-15FFFF 32 120000-127FFF 120000-127FFF
32 150000-157FFF 32 118000-11FFFF 118000-11FFFF
32 148000-14FFFF 32 110000-117FFF 110000-117FFF
32 140000-147FFF 32 108000-10FFFF 108000-10FFFF
32 138000-13FFFF 32 100000-107FFF 100000-107FFF
32 130000-137FFF 32 F8000-FFFFF F8000-FFFFF F8000-FFFFF
32 128000-12FFFF 32 F0000-F7FFF F0000-F7FFF F0000-F7FFF
32 120000-127FFF 32 E8000-EFFFF E8000-EFFFF E8000-EFFFF
32 118000-11FFFF 32 E0000-E7FFF E0000-E7FFF E0000-E7FFF
32 110000-117FFF 32 D8000-DFFFF D8000-DFFFF D8000-DFFFF
32 108000-10FFFF 32 D0000-D7FFF D0000-D7FFF D0000-D7FFF
32 100000-107FFF 32 C8000-CFFFF C8000-CFFFF C8000-CFFFF
32 0F8000-0FFFFF 32 C0000-C7FFF C0000-C7FFF C0000-C7FFF
This column continues on next page This column continues on next page
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 69
16-Mbit, 32-Mbit, and 64-Mbit Word-Wide Memory Addressing
Top Boot Bottom Boot
Size
(KW) 16 Mbit 32 Mbit 64 Mbit Size
(KW) 16 Mbit 32 Mbit 64 Mbit
32 0F0000-0F7FFF 32 B8000-BFFFF B8000-BFFFF B8000-BFFFF
32 0E8000-0EFFFF 32 B0000-B7FFF B0000-B7FFF B0000-B7FFF
32 0E0000-0E7FFF 32 A8000-AFFFF A8000-AFFFF A8000-AFFFF
32 0D8000-0DFFFF 32 A0000-A7FFF A0000-A7FFF A0000-A7FFF
32 0D0000-0D7FFF 32 98000-9FFFF 98000-9FFFF 98000-9FFFF
32 0C8000-0CFFFF 32 90000-97FFF 90000-97FFF 90000-97FFF
32 0C0000-0C7FFF 32 88000-8FFFF 88000-8FFFF 88000-8FFFF
32 0B8000-0BFFFF 32 80000-87FFF 80000-87FFF 80000-87FFF
32 0B0000-0B7FFF 32 78000-7FFFF 78000-7FFFF 78000-7FFFF
32 0A8000-0AFFFF 32 70000-77FFF 70000-77FFF 70000-77FFF
32 0A0000-0A7FFF 32 68000-6FFFF 68000-6FFFF 68000-6FFFF
32 098000-09FFFF 32 60000-67FFF 60000-67FFF 60000-67FFF
32 090000-097FFF 32 58000-5FFFF 58000-5FFFF 58000-5FFFF
32 088000-08FFFF 32 50000-57FFF 50000-57FFF 50000-57FFF
32 080000-087FFF 32 48000-4FFFF 48000-4FFFF 48000-4FFFF
32 078000-07FFFF 32 40000-47FFF 40000-47FFF 40000-47FFF
32 070000-077FFF 32 38000-3FFFF 38000-3FFFF 38000-3FFFF
32 068000-06FFFF 32 30000-37FFF 30000-37FFF 30000-37FFF
32 060000-067FFF 32 28000-2FFFF 28000-2FFFF 28000-2FFFF
32 058000-05FFFF 32 20000-27FFF 20000-27FFF 20000-27FFF
32 050000-057FFF 32 18000-1FFFF 18000-1FFFF 18000-1FFFF
32 048000-04FFFF 32 10000-17FFF 10000-17FFF 10000-17FFF
32 040000-047FFF 32 08000-0FFFF 08000-0FFFF 08000-0FFFF
32 038000-03FFFF 4 07000-07FFF 07000-07FFF 07000-07FFF
32 030000-037FFF 4 06000-06FFF 06000-06FFF 06000-06FFF
32 028000-02FFFF 4 05000-05FFF 05000-05FFF 05000-05FFF
32 020000-027FFF 4 04000-04FFF 04000-04FFF 04000-04FFF
32 018000-01FFFF 4 03000-03FFF 03000-03FFF 03000-03FFF
32 010000-017FFF 4 02000-02FFF 02000-02FFF 02000-02FFF
32 008000-00FFFF 4 01000-01FFF 01000-01FFF 01000-01FFF
32 000000-007FFF 4 00000-00FFF 00000-00FFF 00000-00FFF
Appendix F Device ID Table
Read Configuration Addresses and Data
Item Address Data
Manufacturer Code x16 00000 0089
Device Code
8-Mbit x 16-T x16 00001 88C0
8-Mbit x 16-B x16 00001 88C1
16-Mbit x 16-T x16 00001 88C2
16-Mbit x 16-B x16 00001 88C3
32-Mbit x 16-T x16 00001 88C4
32-Mbit x 16-B x16 00001 88C5
64-Mbit x 16-T x16 00001 88CC
64-Mbit x 16-B x16 00001 88CD
NOTE: Other locations within the configuration address
space are reserved by Intel for future use.
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 71
Appendix G Protection Register Addressing
Word-Wide Protection Register Addressing
WordUseA7A6A5A4A3A2A1A0
LOCKBoth10000000
0Factory10000001
1Factory10000010
2Factory10000011
3Factory10000100
4User10000101
5User10000110
6User10000111
7User10001000
NOTE: All address lines not specified in the above table must be 0 when accessing the Protection Register, i.e., A21–A8=0.
28F800C3, 28F160C3, 28F320C3, 28F640C3
72 Datasheet
Appendix H VF Pitch BGA Package Drawing and
Dimensions
Figure 18. VF BGA Drawing and Dimensions
M illimet ers Inches
Symbol Min Nom M ax Notes Min Nom Max
Pac kag e Height A 1.000 0.0394
Ball He igh t A 10.15 0 0.0059
Package Body Thickness A20.665 0.0262
Ball (Lead) W idth b 0.32 5 0.375 0.425 0.0128 0.0148 0.0 167
Pac kag e Bo dy W idth ( 16Mb / 32Mb ) D 7.186 7.286 7.386 1 0.2829 0.2869 0.2908
Pac kag e Bo dy W idth (64Mb ) D 7.600 7.700 7.800 1 0.2994 0.3033 0.3073
Pac kag e Bo dy Len g th (16M b/ 32Mb) E 6.864 6.964 7.064 1 0.2702 0.2742 0.2781
Pac kag e Bo dy Len g th (64M b) E 8.900 9.000 9.100 1 0.3506 0.3546 0.3585
Pitch [e ] 0.750 0.0295
Ball (Lead) Count (16Mg) N 46 2 46
Ball (Lead) Count (32Mg) N 47 2 47
Ball (Lead) Count (64Mg) N 48 2 48
Sea ting Plan e Co plan arity Y 0.100 0.0039
Corner to Ball A1 Distance Along D ( 16Mb 32Mb ) S10.91 8 1.018 1.118 1 0.0361 0.0401 0.0440
Corner t o Ball A1 Distance Along D (64M b) S11.125 1.225 1.325 1 0.0443 0.0482 0.0522
Corner t o Ball A1 Dis tance Alon g E (16M b/32Mb) S21.507 1.607 1.707 1 0.0593 0.0633 0.0672
Corner t o Ball A1 Distance Along E (64Mb) S22.525 2.625 2.725 1 0.0994 0.1034 0.1073
N
ote: 1.) Package dimensions are for reference only. These dimensions are estimates based on die size, and are subject to change.
2.) For 16 M bit devi ces A20 and A2 1 are not popu lated.
Dimensions
Bottom View -Bump side up
e
b
S1
Ba ll A1
Corner
Top View - Bump Side down
Ball A1
Corner
E
D
Side View
A
A2
A1
Seating Y
A
B
C
D
E
F
S2
Plan
123
4
5678
A
B
C
D
E
F
12345678
Note: Drawing not to scale
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 73
Appendix I Easy BGA Package Drawing & Dimensions
Millimeters Inches
Symbol Min Nom Max Notes Min Nom Max
Package Height A 1.200 0.0472
Ball He ig h t A10.250 0.0098
Package Body Thickness A20.780 0.0307
Ball (Lead) Widt h b 0.330 0.430 0.530 0.0130 0.0169 0.0209
Package Body Width D 9.900 10.000 10.100 1 0.3898 0.3937 0.3976
Package Body Length E 12.900 13.000 13.100 1 0.5079 0.5118 0.5157
Pitch [e] 1.000 0.0394
Ball (Lead) Count N 64 64
Seating Plane Coplanarity Y 0.100 0.0039
Corn er t o Ball A1 Dis t an ce Along D S11.400 1.500 1.600 1 0.0551 0.0591 0.0630
Corn er t o Ball A1 Dis t an ce Along E S22.900 3.000 3.100 1 0.1142 0.1181 0.1220
Dimensions Table
Note: (1) Package dimensions are for reference only. These dimensions are estimates based
on die size, and are subject to change.
E
Seating
Plane
S1
S2
e
Top View - Ball side down Bottom View - Ball Side Up
Y
A
A1
D
Ball A1
Corner
A2
Note: Drawing not to scal e
A
B
C
D
E
F
G
H
8765432187654321
A
B
C
D
E
F
G
H
b
Ball A1
Corner
Side View
28F800C3, 28F160C3, 28F320C3, 28F640C3
74 Datasheet
Appendix J Additional Information
Order Number Document/Tool
297938 3 Volt Advanced+ Boot Block Flash Memory Specification Update
292216 AP-658 Designing for Upgrade to the Advanced+ Boot Block Flash Memory
292215 AP-657 Designing with the Advanced+ Boot Block Flash Memory
Architecture
Contact your Intel
Representative Intel®Flash Data Integrator (IFDI) Software Developer’s Kit
297874 IFDI Interactive: Play with Intel®Flash Data Integrator on Your PC
NOTES:
1. Please call the Intel Literature Center at (800) 548-4725 to request Intel documentation. International
customers should contact their local Intel or distribution sales office.
2. Visit Intel’s World Wide Web home page at ‘http://www.intel.com/design/flash for technical
documentation and tools.
28F800C3, 28F160C3, 28F320C3, 28F640C3
Datasheet 75
Appendix K Ordering Information
VALID COMBINATIONS (All Extended Temperature)
48-Lead TSOP 48-Ball µBGA* CSP 48-Ball VF BGA Easy BGA
Extended
64 Mbit
TE28F640C3TC80
TE28F640C3BC80
GE28F640C3TC80
GE28F640C3BC80
RC28F640C3TC80
RC28F640C3BC80
Extended
32 Mbit
TE28F320C3TC70
TE28F320C3BC70
TE28F320C3TC90
TE28F320C3BC90
TE28F320C3TA100
TE28F320C3BA100
TE28F320C3TA110
TE28F320C3BA110
GT28F320C3TA100
GT28F320C3BA100
GT28F320C3TA110
GT28F320C3BA110
GE28F320C3TD70
GE28F320C3BD70
GE28F320C3TC70
GE28F320C3BC70
GE28F320C3TC90
GE28F320C3BC90
RC28F320C3TD70
RC28F320C3BD70
RC28F320C3TC90
RC28F320C3BC90
RC28F320C3TA100
RC28F320C3BA100
RC28F320C3TA110
RC28F320C3BA110
Extended
16 Mbit
TE28F160C3TC70
TE28F160C3BC70
TE28F160C3TC80
TE28F160C3BC80
TE28F160C3TC90
TE28F160C3BC90
TE28F160C3TA90
TE28F160C3BA90
TE28F160C3TA110
TE28F160C3BA110
GT28F160C3TA90
GT28F160C3BA90
GT28F160C3TA110
GT28F160C3BA110
GE28F160C3TC70
GE28F160C3BC70
GE28F160C3TC80
GE28F160C3BC80
GE28F160C3TC90
GE28F160C3BC90
RC28F160C3TC70
RC28F160C3BC70
RC28F160C3TC80
RC28F160C3BC80
RC28F160C3TC90
RC28F160C3BC90
RC28F160C3TA90
RC28F160C3BA90
RC28F160C3TA110
RC28F160C3BA110
Extended
8Mbit
TE28F800C3TA90
TE28F800C3BA90
TE28F800C3TA110
TE28F800C3BA110
GE28F800C3TA70
GE28F800C3BA70
GE28F800C3TA90
GE28F800C3BA90
RC28F800C3TA90
RC28F800C3BA90
RC28F800C3TA110
RC28F800C3BA110
NOTE: The second line of the 48-ball µBGA package top side mark specifies assembly codes. For samples
only, the first character signifies either “E” for engineering samples or “S” for silicon daisy chain
samples. All other assembly codes without an “E” or S” as the first character are production units.
Lithography
A = 0.25 µm
C = 0.18 µm
D = 0.13 µm
Package
TE = 48-Lead TSOP
GT = 48-Ball µBGA* CSP
GE = VF BGA CSP
RC = Easy BGA
Access Speed (ns)
(70, 80, 90, 100, 110)
Product Family
C3 = 3 Volt Advanced+ Boot Block
VCC =2.7V3.6V
VPP =2.7V3.6Vor
11.4 V12.6 V
Device Density
640 = x16 (64 Mbit)
320 = x16 (32 Mbit)
160 = x16 (16 Mbit)
800=x16(8Mbit)
T=Top Blocking
B=Bottom Blocking
T E 2 8 F 3 2 0 C 3 T C 7 0
Product line designator
for all Intel®Flash products