Your Contact for Relays SECTION SOLID STATE RELAYS (SSR) 2.5 TO 125 AMPERES 2 SOLID STATE RELAYS 6 (ASX) SSRDIN 6 (DSX) RELAY SERIES L.E.D. STATUS LAMP FEATURES L W H 2.25 x 1.75 x 0.78 L W H 4.015 x 1.180 x 4.527 AC & DC INPUT AC INPUT L W H 2.25 x 1.75 x 0.78 DC INPUT AC OUTPUT AC OUTPUT AC OUTPUT 10 OR 25 AMP LOADS UP TO 125 AMP LOADS UP TO 125 AMP LOADS PHOTO ISOLATED, ZERO VOLTAGE SWITCHING PHOTO ISOLATED, ZERO VOLTAGE SWITCHING 4000V rms ISOLATION INPUT TO OUTPUT 4000V rms ISOLATION INPUT TO OUTPUT PHOTO ISOLATED, ZERO VOLTAGE SWITCHING 4000V rms ISOLATION INPUT TO OUTPUT INTERNAL RC (SNUBBER) NETWORK RFI SUPPRESSION INTERNAL RC (SNUBBER) NETWORK INTERNAL RC (SNUBBER) NETWORK INTEGRAL SAFETY COVER, AND HEATSINK. RFI SUPPRESSION RFI SUPPRESSION DIN RAIL MOUNTING SAFETY COVER STANDARD SAFETY COVER STANDARD OUTPUT DATA OUTPUT CONFIGURATION: LOAD VOLTAGE: LOAD CURRENT MAX.: OUTPUT DEVICE: MINIMUM LOAD: INSULATION CHARACTERISTICS DIELECTRIC STRENGTH: L.E.D. STATUS LAMP L.E.D. STATUS LAMP SPST-NO SPST-NO SPST-NO 280, 660 VAC 10 & 25 AMPS 280, 560 OR 660 VAC 10 TO 125 AMPS 280, 560 OR 660 VAC 10 TO 125 AMPS BACK TO BACK SCRS 50 TO 250 MILLIAMPS BACK TO BACK SCRS 50 TO 500 MILLIAMPS BACK TO BACK SCRS 50 TO 500 MILLIAMPS 4000 V rms 4000 V rms 4000 V rms 90 TO 280 VAC, 3 TO 32 VDC 90 TO 280 VAC 3 TO 32 VDC 16 mA TYPICAL 20 mA TYPICAL 16 mA TYPICAL 10 VAC OR 1 VDC 10 VAC 1 VDC - 30C TO +80C - 40C TO +100C - 40C TO +80C - 40C TO +100C - 40C TO +80C - 40C TO +100C AC: 40 mS, DC 10 mS AC: 80 mS, DC 10 mS 1010 SCREW 40 mS 80 mS 1010 SCREW 40 mS 80 mS 1010 SCREW INPUT DATA INPUT VOLTAGE RANGE: INPUT CURRENT: MUST TURN OFF VOLTAGE: GENERAL DATA AMBIENT TEMPERATURE OPERATIONAL: STORAGE: RESPONSE TIME OPERATE MAX.: RELEASE MAX: INSULATION RESISTANCE: TERMINALS: AGENCY APPROVALS C US UL Recognized File No. E52197 PAGE NUMBER 2...1 PAGE 8 C US UL Recognized File No. E52197 C CE APPROVED ON SELECT MODELS US UL Recognized File No. E52197 PAGE 9 CONSULT FACTORY FOR OTHER CONFIGURATIONS CE APPROVED ON SELECT MODELS PAGE 10 SOLID STATE RELAYS 6 (DDX) 6 (DTX) 6 (DTX) L.E.D. STATUS LAMP L.E.D. STATUS LAMP L.E.D. STATUS LAMP L W H 2.25 x 1.75 x 0.78 L W H 2.25 x 1.75 x 0.78 L W H 2.25 x 1.75 x 0.78 DC INPUT DC INPUT DC INPUT DC OUTPUT AC OUTPUT AC TRIAC OUTPUT UP TO 40 AMP LOADS UP TO 40 AMP LOADS 10 AMP LOADS ISOLATED, 2500 V rms ISOLATION INPUT TO OUTPUT PHOTO ISOLATED ZERO VOLTAGE SWITCHING PHOTO ISOLATED ZERO VOLTAGE SWITCHING RFI SUPPRESSION 4000 V rms ISOLATION INPUT TO OUTPUT 4000V rms ISOLATION INPUT TO OUTPUT SAFETY COVER STANDARD INTERNAL RC (SNUBBER) NETWORK INTERNAL RC (SNUBBER) NETWORK L.E.D. STATUS LAMP SAFETY COVER STANDARD RFI SUPPRESSION SPST-NO SPST-NO, SPST-NC DPST-NO 200 VDC 12, 25 & 40 AMPS 280 OR 560 VAC 10, 25 OR 40 AMPS 280 VAC 10 AMPS MOSFET 20 MILLIAMPS TRIAC 50 TO 250 MILLIAMPS TRIAC 50 MILLIAMPS 2500 V rms 4000 V rms 4000 V rms 3.5 TO 32 VDC 3 TO 32 VDC 3.5 TO 32 VDC 10 mA TYPICAL 2 mA TYPICAL 2 mA TYPICAL 1 VDC 1 VDC 1 VDC - 40C TO +80C - 40C TO +100C - 40C TO +80C - 40C TO +100C - 40C TO +80C - 40C TO +100C 600 uSec 2.6 mSec 1010 SCREW 40 mS 80 mS 1010 SCREW 40 mS 80 mS 1010 QUICK CONNECTS C US UL Recognized File No. E52197 PAGE 11 C US C US UL Recognized File No. E52197 UL Recognized File No. E52197 PAGE 12 PAGE 13 CONSULT FACTORY FOR OTHER CONFIGURATIONS 2...2 SOLID STATE RELAYS 70S2 70S2 " V " STYLE " N " & " S " STYLES 70S2 " F " & " M " STYLES RELAY SERIES DC INPUT DC INPUT L W H 2.20 x 1.00 x 0.85 DC INPUT AC OR DC OUTPUT AC OR DC OUTPUT AC OR DC OUTPUT 3 AMP LOADS UP TO 25 AMP LOADS UP TO 10 AMP LOADS OPTICALLY ISOLATED OPTICALLY ISOLATED OPTICALLY ISOLATED SINGLE IN-LINE PACKAGE COMPACT SIZE PRINTED CIRCUIT TERM OR PANEL MOUNT L W H 2.20 x 1.00 x 0.864 L W H 1.70 x 0.400 x 1.00 FEATURES FORMERLY GRAYHILL OUTPUT DATA FORMERLY GRAYHILL SPST-NO SPST-NO SPST-NO 50, 140, 280 VAC,60 VDC 3 AMPS 140 OR 280 VAC,60 VDC 6, 12 OR 25 AMPS 140 OR 280 VAC OR 60 VDC 3,4,6 & 10 AMPS TRIAC (AC) OR TRANSISTOR (DC) 65 MILLIAMPS TRIAC (AC) OR TRANSISTOR (DC) 65 MILLIAMPS TRIAC (AC) OR TRANSISTOR (DC) 65 MILLIAMPS 2500 V rms 2500 V rms 2500 V rms 3 TO 32 VDC 3 TO 30 VDC 3 TO 30 VDC 1.0 to 19 m A TYPICAL 1.0 TO 19 mA TYPICAL 1.0 TO 16 mA TYPICAL 1 VDC 1 VDC 1 VDC - 40C TO +100C - 40C TO +125C - 40C TO +100C - 40C TO +125C - 40C TO +100C - 40C TO +125C 8.3 mS 8.3 mS 1010 PRINTED CIRCUIT 8.3 mS 8.3 mS 1010 QUICK CONNECTS OR SCREW 8.3 mS 8.3 mS 1010 PRINTED CIRCUIT OUTPUT CONFIGURATION: LOAD VOLTAGE: LOAD CURRENT MAX.: OUTPUT DEVICE: MINIMUM LOAD: FORMERLY GRAYHILL INSULATION CHARACTERISTICS DIELECTRIC STRENGTH: INPUT DATA INPUT VOLTAGE RANGE: INPUT CURRENT: MUST TURN OFF VOLTAGE: GENERAL DATA AMBIENT TEMPERATURE OPERATIONAL: STORAGE: RESPONSE TIME OPERATE MAX.: RELEASE MAX.: INSULATION RESISTANCE: TERMINALS: AGENCY APPROVALS C US UL Recognized File No. E52197 PAGE NUMBER 2...3 C 168986 PAGE 16 TUV on Selected models C US UL Recognized File No. E52197 168986 PAGE 17 - 18 CONSULT FACTORY FOR OTHER CONFIGURATIONS US UL Recognized File No. E52197 168986 PAGE 19 - 20 SOLID STATE RELAYS 70S2 " H " & " L" STYLES 70S2 226 " K " STYLE L W H 1.20 x 1.00 x 0.830 L W H 1.20 x 1.00 x 0.520 DC INPUT DC INPUT DC INPUT AC OUTPUT AC OUTPUT AC OUTPUT UP TO 6 AMP LOADS UP TO 6 AMP LOADS UP TO 7 AMP LOADS OPTICALLY ISOLATED OPTICALLY ISOLATED PHOTO ISOLATED PRINTED CIRCUIT TERMINAL OR PANEL MOUNT QUICK CONNECT TERMINAL OR PANEL MOUNT RANDOM TURN-ON L W H 1.50 X 0.670 X 0.600 COMPATABLE WITH TTL GATES MOUNTS ON TO -3 TRANSISTOR HEAT SINKS FORMERLY GRAYHILL FORMERLY GRAYHILL SPST-NO SPST-NO SPST-NO 140 OR 280 VAC 2.5 OR 6 AMPS 140 OR 280 VAC 4 AMPS 140 OR 280 VAC 7 AMPS TRIAC (AC) OR TRANSISTOR (DC) 65 MILLIAMPS TRIAC (AC) OR TRANSISTOR (DC) 65 MILLIAMPS TRIAC 50 MILLIAMPS 2500 V rms 3000 V rms 2500 V rms 3 TO 30 VDC 3 TO 30 VDC 5 & 12 VDC 1.0 TO 18 mA TYPICAL 1.0 TO 18 mA TYPICAL 10 mA TYPICAL 1 VDC 1 VDC 1.4 VDC - 40C TO +100C - 40C TO +125C - 40C TO +100C - 40C TO +125C - 30C TO +80C - 40C TO +100C 8.3 mS 8.3 mS 1010 PRINTED CIRCUIT 8.3 mS 8.3 mS 1010 PRINTED CIRCUIT 10 mS 60 mS 1010 PRINTED CIRCUIT OR PUSH ON C C US UL Recognized File No. E52197 168986 PAGE 21 - 22 US UL Recognized File No. E52197 168986 PAGE 23 - 24 CONSULT FACTORY FOR OTHER CONFIGURATIONS UL Recognized File No. E52197 PAGE 25 2...4 SOLID STATE RELAYS SOLID STATE RELAYS APPLICATION DATA INTRODUCTION: APPLICATION AND SELECTION CRITERIA FOR SOLID STATE RELAYS: SOLID STATE RELAY (SSR) is a relay with isolated input and output, whose functions are achieved by means of electronic components without the use of moving parts as found in electromechanical relays. The Chart below indicates the areas in which SSR's (Solid State Relays) or EMR's (Electromechanical Relays) have better capabilities. (X) Indicates the Better choice. PRINCIPLE OF OPERATION: Solid State Relays are similar to electromechanical relays, in that both use a control circuit and a separate circuit for switching the load. When voltage is applied to the input of the SSR, the relay is energized by a light emitting diode. The light from the diode is beamed into a light sensitive semiconductor which, in the case of zero voltage crossover relays, conditions the control circuit to turn on the output solid state switch at the next zero voltage crossover. In the case of nonzero voltage crossover relays, the output solid state switch is turned on at the precise voltage occurring at the time. Removal of the input power disables the control circuit and the solid state switch is turned off when the load current passes through the zero point of its cycle. APPLICATIONS: Solid State Relays are specially suitable in many applications. Listed below are some typical applications. INDUSTRIAL AUTOMATION ALARM SYSTEMS ELECTRONIC APPLIANCES Long life Temperature cycling Shock and vibration resistant Immunity to false operation due to transients Generation of RFI, EMI Multipole Multithrow (SPDT) Size (includes Heat Sink) for equivalent load handling Contact bounce Arcless switching Acoustic noise Zero voltage switching Ease of diagnosing malfunction IC compatibility Immunity to humidity, salt spray & dirt SSR EMR X X X X X X X X X X X X X X X LOAD CONSIDERATIONS A major portion of application problems with SSR's result from operating conditions which specific loads impose upon an SSR. The following types of loads point out the potential problems that can occur with SSR's. DC LOADS: All loads should be considered inductive and a diode should be placed across the load to absorb any inductive surge on turnoff. RESISTIVE LOADS: Loads of constant value resistance are probably the simplest application of SSR's. Proper attention to the steady state current ratings and applied blocking voltage specifications normally will result in trouble-free operation. INDUSTRIAL APPLIANCES TOOLING MACHINGS 2 5 MEDICAL EQUIPMENT PACKING MACHINES LAMP LOADS: Incandescent lamp loads, though basically resistive, present some special problems. Because the resistance of a cold tungsten filament is about five to ten percent of the heated value, a large inrush current can occur. The period of the inrush current can range from one half cycle to several cycles, depending on the thermal time constant of the filament. It is essential to verify that this inrush current is within the surge specifications of the SSR. Also check that the lamp rating of the SSR is not exceeded. This is a UL rating based on the inrush of a typical lamp. Because of the unusually low filament resistance at the time of turn-on, a zero voltage turn-on characteristic is particularly desirable with tungsten lamps. It has been demonstrated that a zero voltage turn-on can extend the life of tungsten lamps by limiting inrush current. SOLID STATE RELAYS APPLICATION DATA MOTORS: Motors frequently have severe inrush currents during starting and can impose unusual voltages during turnoff. The inrush currents connected to mechanical loads having high starting torque or inertia should be carefully determined to verify that they are within the surge capabilities of the SSR. A current shunt and oscilloscope should be used to examine the duration of the inrush current. Motor starting may frequently reoccur at short intervals and the affect of repetitive inrush currents on the thermal operating point of an SSR must be considered. Check the motor operating current and locked rotor current versus the SSR motor rating. The possibility of abnormally stalled rotor conditions which draw much higher than normal currents should be considered. An extended stalled rotor condition may require an oversized SSR or fuse protection. The generated EMF of certain motors can require an SSR to have a blocking voltage greater than might be expected from steady state line voltage. The voltage applied to an SSR by a motor circuit during turnoff should be examined with an oscilloscope to verify hat the applied voltages are safely below the specified SSR blocking voltages. Otherwise lock-on or erratic turnoff of the motor may occur. Some motor circuits may require higher than normal blocking voltage, transient limiting devices, or other techniques to control the voltage which must be blocked by an SSR during deceleration or direction reversal. TRANSFORMERS: In controlling transformers, the characteristics of the secondary load should be considered because it reflects the effective load on the SSR. Voltage transients from secondary load circuits, similarly, are frequently transformed and can be imposed on the SSR. Transformers present a special problem in that, depending on the state of the transformer flux at the time of turnoff, the transformer may saturate during the first half-cycle of subsequent applied voltage. This saturation can impose a very large current (Commonly ten to one hundred times rated primary current) on the SSR and exceed its half-cycle surge rating. portion of the first half-cycle of the voltage. On the other hand, a random turn-on device will frequently close at the essentially zero voltage point (start of the half-cycle) and then the SSR must sustain the worstcase saturation current. A zero voltage turn-on device has the advantage that it turns on in a known, predictable mode and will normally immediately demonstrate (dependent on turnoff flux polarity) the worst-case condition. The use of an oscilloscope is recommended to verify that the half-cycle surge capability of the SSR is not exceeded. The severity of the transformer saturation problem varies greatly, dependent on the magnetic material of the transformer, saturated primary impedance, line impedance, etc. A safe rule of thumb in applying an SSR to a transformer primary is to select an SSR having a half-cycle current surge rating (RMS) greater than the maximum applied line voltage (RMS) divided by the transformer primary resistance. The primary resistance is usually easily measured and can be relied on as a minimum impedance limiting the first half-cycle of inrush current. The presence of some residual flux plus the saturated reactance of the primary will then further limit, in the worst case, the half-cycle surge safely within the surge rating of the SSR. SELECTING THE PROPER SSR NOMINAL LOAD CURRENT: Initially select a relay whose current rating exceeds the normal load current. Using the load current vs, temperature charts for that relay, check the actual current capacity at the ambient temperature to which the relay will be subjected. As an example, the chart shows that a 25 ampere relay provided with a suitable heat sink can safely carry a maximum of 22 amperes continuously 25 Amp Styles at 40C ambient. 40 Since heat degrades Mounted on Heat Sink with 1C/W thermal resistance. 35 the components (Sink to Ambient) 30 ability to carry current, every 25 effort should be 20 made to keep the 15 6" x 6" x 1/8" operating Aluminum 10 temperature of Plate 5 the SSR as low as possible. LOAD CURRENT (AMPS RMS) CAPACITIVE LOADS: Caution must be used with low impedance capacitive loads to verify that the di/dt capabilities are not exceeded. The di/dt of a discharged capacitive load without external limiting impedance can approach infinity. Zero voltage turn-on is a particularly valuable means of limiting di/dt with capacitive loads. 20 40 60 80 100 MAX. AMBIENT TEMPERATURE (C) SSR's having random turn-on may have a better chance of survival than a zero voltage turn-on device for they commonly require the transformer to support only a 2 6 SOLID STATE RELAYS APPLICATION DATA PROTECTING THE OUTPUT SWITCH: The last three methods can be protected against as follows. In those situations where high peak voltage transients occur, effective protection can be obtained by using metal oxide varistors (MOV). The MOV is a bidirectional voltage sensitive device that has low impedance when its design voltage threshold is exceeded. An SCR is a four layer semiconductor having 3 terminals: Cathode, anode and Gate. Normally it blocks current in both the forward and reverse directions. The SCR is triggered on in the forward direction by a small gate current. The SCR remains on until load current decreases to a value less than necessary to maintain the SCR in the on state. When switching AC, two SCRS are connected in inverse parallel. HEAT SINKING: It is important to select the right size heat sink for your applications. SSR's will typically generate 1.2 watts per amp of load current. The total wattage times the thermal resistance equal the temperature. For example a 25 amps SSR with a 20 amps load applied dissipates 24 watts when mounted on a aluminum plate 6" X 6" X 1/8" with thermal grease applied between the SSR base and aluminum plate. 20 amps x 1.2 watts / amp = 24 watts. 24 watts x 1C / watts = 24C rise. A Triac also has 3 terminals, like the SCR, it normally blocks current in both directions; but may be triggered in either direction by a small gate current Both SCR's and Triacs are members of the thyristor family. Therefore, we use this term to denote both devices. There are 4 ways to put a thyristor into a conducting mode. Only one method is desirable and the other three are the source of most application problems. FUSING: The SSR has a I2 T rating which is a measure of the amount of energy it can safely handle without damage. The I2 T rating of the fuse is a measure of the amount of energy the fuse will pass to the SSR. To protect the SSR, an inline fuse rating should be less than that of the SSR. An SSR exposed to a surge greater than its non-repetitive rating will normally fail as a shorted unit. The 4 methods of Thyristor turn-on are A. Gate Turn-on: By injecting a controlled current into the gate (the desired method). B. Forward Breakover Turn-on: A voltage in excess of the Breakover (or Peak Blocking) voltage across thyristor. EXPRESSIONS USED IN SPECIFICATIONS dv dt C. DV/DT turn-on: A voltage which rises faster than the Thyristor can tolerate, and still remain in the off state. Equals the maximum permissable rate of change of voltage in volts/microseconds V= Line Voltage I= Load Current PF= Load Power Factor F= Line Frequency L= Inductance in Henrys C= Capacitance in Microfarads R1&R2 = Resistance in Ohms D. Thermal Turn-on: Allowing the temperature of the thyristor to go beyond the value sufficient to cause excessive leakage current, causing turn-on and possible thermal runaway. SOLID STATE RELAY SELECTION CHART CONTROL VOLTAGE LOAD VOLTAGE 2 H PACK L PACK F PACK 240 VAC V PACK PC BOARD (SIP) 3 - 30VDC or K PACK SOCKET 60 VDC M PACK N PACK PANEL S PACK W6 series (DDX 200 VDC 600 VAC W6 series (DSX) PANEL 480 VAC W6 series (DTX) SSR-DIN-DC DIN/PANEL 600 VAC SSR-DIN-AC W6 series (ASX) PANEL 90 - 280VAC 5 or 12 VDC PC/PUSH ON TERM. W226 PC BOARD 2...7 LOAD CURRENT AMPS MOUNTING 3 4 5 6 10 12 25 40 50 75 90 125 PAGE 21 - 22 21 - 22 19 - 20 16 23 - 24 19 - 20 17 - 18 17 - 18 12 11 13 - 14 8 8 10 25 CLASS SSRDIN SOLID STATE DIN MOUNT RELAY SPST-N.O., 10 & 25 AMPS AC & DC CONTROLLED INPUT INTEGRAL HEATSINK ONLY OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). c 30 MILLIMETERS WIDE PANEL/DIN MOUNTABLE (35 mm RAIL) 4.015 (102) LOAD CURRENT (AMPS RMS) LOAD CURRENT (AMPS RMS) FINGER SAFE COVER L. E. D. STATUS LAMP. 3.62 (91.940) 10 Amp Styles 12 RED L.E.D. STATUS LAMP O 0.196 (5.0) 0.468 (11.9) 10 us UL Recognized File No. E52197 8 6 3.188 MAX. (80.97) 4 1.181 (30) 2 0 0 10 20 30 40 50 60 70 80 90 1.20 (30.5) MAX. AMBIENT TEMPERATURE (C) 25 Amp Styles 4.527 MAX. (115) 25 20 RECOMMEND SPACING BETWEEN MULTIPLE SSR'S 0.75 INCH 15 10 5 0 0 10 20 30 40 50 60 70 80 90 3.050 (77.47) MAX. AMBIENT TEMPERATURE (C) 0.866 (22) GENERAL SPECIFICATIONS INPUT CHARACTERISTICS Control Voltage Range: Typical Input Current: Must Release Voltage: Reverse Polarity Protection: Power Indicator: DIN-AC: 90-280 VAC / DIN-DC: 3 - 32 VDC AC: 12 mA; DC: 16 mA 10 VAC / 1 VDC DC: Yes Red L. E. D. Status lamp OUTPUT CHARACTERISTICS Style: SSR: 210DIN-AC 225DIN-AC 610DIN-AC 625DIN-AC 210DIN-DC 24-280 VAC 24-280 VAC 48-660 VAC 48-660 VAC 24-280 VAC Load Voltage Range: 25 Amp 10 Amp 10 Amp 25 Amp 10 Amp Rated Load Current: 500 uS 200 uS 200 uS 700 uS 200 uS Maximum Off-State Voltage dv/dt: 120 mA 50 mA 80 mA 250 mA 50 mA Minimum Load Current: 800 A 83 A 83 A 1000 A 83 A Non -Repetitive Surge Current (1 Cycle): 10 mA 10 mA 10 mA 10 mA 10 mA Maximum Off State Leakage current (Rms): 1.35 VAC 1.25 VAC 1.25 VAC 1.35VAC 1.25 VAC Typical On-State Voltage Drop (Rms): 2 2 3700 83 83 1700 83 Maximum I T For Fusing (A Sec): Operating Frequency Range: 25 Hz to 70 Hz Maximum Turn - On Time: AC: 40 mS / DC: 10 mS Maximum Turn - Off Time: AC: 80 mS / DC: 10 mS 225DIN-DC 610DIN-DC 625DIN-DC 24-280 VAC 48-660 VAC 48-660 VAC 10 Amp 25 Amp 25 Amp 200 uS 700 uS 500 uS 80 mA 250 mA 120 mA 83 A 1000 A 800 A 10 mA 10 mA 10 mA 1.25 VAC 1.25VAC 1.35 VAC 83 1700 3700 MISCELLANEOUS CHARACTERISTICS Dielectric Strength (Input-to Output Isolation): 4000 V rms Insulation Resistance: 1010 Operating Temperature Range: -30C to +80C Storage Temperature Range: -40C to +100C Weight: 340 grams approx. CONSULT FACTORY FOR OTHER CONFIGURATIONS PART NUMBERS RATED LOAD CURRENT SSR210DIN-AC SSR225DIN-AC SSR610DIN-AC SSR625DIN-AC SSR210DIN-DC SSR225DIN-DC SSR610DIN-DC SSR625DIN-DC 10 AMPS 25 AMPS 10 AMPS 25 AMPS 10 AMPS 25 AMPS 10 AMPS 25 AMPS 2...8 CLASS 6 SOLID STATE RELAY SPST-N.O. 10 TO 125 AMPS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). RED L.E.D. STATUS LAMP +3 OUTPUT -1 RED L.E.D. c us UL Recognized On selected File No. E52197 models SAFETY COVER STANDARD ON ALL MODELS EXCEPT DUAL OUTPUT 1.750 (44.5) +2 INPUT -4 2.250 (57.2) LIFETIME WARRANTY INPUT OUTPUT 2.665 (67.691) SAFETY COVER 0.475 (12.065) 0.800 INPUT & OUTPUT SCREW SIZE (20.32) 0.185 MAX. (4.699) UP TO 40 AMP INPUT M 3.5 ABOVE 40 AMP 1.945 (49.403) 0.996 Max. (25.3) for 40 Amp DDX Models & for 75 to 125 Amps DSX & ASX Models. M 3.5 OUTPUT M4 M6 0.800 Max (20.32) for Models ASX, DSX & DTX Models up to 50 Amp & DDX 12 Amp Models. THERMAL DERATING CURVE & LOAD CHARACTERISTICS 12 Heat Sink with 1C/W thermal resistance. 8 6 4 Free Air Mounting 2 0 20 40 60 80 100 30 25 20 15 6" x 6" x 1/8" 10 Aluminum Plate 20 DENOTES STOCK: CLASS: LOAD VOLTAGE RAMGE: 24 - 280 VAC: CODE 2 48 - 560 VAC: CODE 4 48 - 600 VAC: CODE 6 RATED LOAD CURRENT: 10 AMPS, 25 AMPS, 40 AMPS, 50 AMPS, 75 AMPS, 90 AMPS, 125 AMPS 2 9 INPUT/OUTPUT STYLE: AC INPUT / AC OUTPUT - ASX (SCR) DC INPUT / AC OUTPUT - DSX (SCR) DC INPUT / AC OUTPUT - DTX (TRIAC) DC INPUT / DC OUTPUT - DDX (MOSFET) 80 100 -90 60 6" x 6" x 1/8" Aluminum Plate 45 0.14C/W 40 -95 -100 30 -105 20 -110 10 0 0 0.14C/W(50A) 50 6" x 6" x 1/8" Aluminum Plate 40 30 20 10 0 20 40 60 80 100 MAX. AMBIENT TEMPERATURE (C) 75 LOAD CURRENT (AMPS RMS) 2 10 ASX- 60 1C/W thermal resistance. 70 75 Amp Styles ORDERING CODE FOR RELAYS 6 40 80 Mounted on Heat Sink with MAX. AMBIENT TEMPERATURE (C) MAX. AMBIENT TEMPERATURE (C) W 1.5C/W 5 180 10 20 30 40 50 60 70 80 MAX. AMBIENT TEMPERATURE (C) LOAD CURRENT (AMPS RMS) 10 35 LOAD CURRENT (AMPS RMS) 6" x 6" x 1/8" Aluminum Plate 40 & 50 Amp Styles 90 Mounted on Heat Sink with 1C/W thermal resistance. (Sink to Ambient) MAX. ALLOWABLE TEMPERATURE 14 25 Amp Styles 40 LOAD CURRENT (AMPS RMS) LOAD CURRENT (AMPS RMS) 10 Amp Styles 16 160 140 90 & 125 Amp Styles HEAT SINK 0.14C/W 125 Amp 120 Fan output 70 CFM With Fan 100 90 Amp 80 60 40 Without Fan 20 10 20 30 40 50 60 70 80 90 MAX. AMBIENT TEMPERATURE (C) ALL CURRENT RATINGS ON THE FOLLOWING PAGES ARE BASED ON USE OF A SUITABLE THERMALLY CONDUCTIVE COMPOUND (E.G. SILICONE GREASE BETWEEN THE SSR MOUNTING BASE AND THE MOUNTING SURFACE OF A SUITABLE HEAT SINK). PHONE: ( 843 ) 393-5778 FAX: ( 843 ) 393-4123 EMAIL: info@magnecraft.com CLASS 6 SOLID STATE RELAY ASX SERIES SPST-N.O. 10 TO 125 AMPS AC CONTROLLED INPUT AC SCR OUTPUT. L. E. D. STATUS LAMP c On selected models RED L.E.D. STATUS LAMP GENERAL SPECIFICATIONS COMPLIES WITH REQUIREMENTS OF * IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE = INTERNATIONAL * IEC ELECTROTECHNICAL COMMISSION INPUT CHARACTERISTICS Control Voltage Range: Typical Input Current: Must Release Voltage: Power Indicator: OUTPUT CHARACTERISTICS Style: Load Voltage Range: Rated Load Current: Maximum Off-State Voltage dv/dt: Minimum Load Current: Non -Repetitive Surge Current (1 Cycle): Maximum off State Leakage current (Rms): Typical On-State Voltage Drop (Rms): Maximum I2T for Fusing (A2 Sec): Suggested Heatsink C/W: Operating Frequency Range: Maximum Turn - On Time: Maximum Turn - Off Time: us UL Recognized File No. E52197 TESTING AND EVALUATION * CE PERFORMED BY THE UNDERWRITERS 90 - 280 VAC 20 mA 10 VAC Red L. E. D. Status lamp LABORATORIES AS A THIRD PARTY PARTICIPANT W62 W64 W66 48 - 660 VAC 48 - 560 VAC 40 - 280 VAC 10 Amp 25 Amp 40 Amp 50 Amp 75 Amp 10 Amp 25 Amp 40 Amp 50 Amp 75 Amp 90 Amp 125 Amp 200 uS 500 uS 500 uS 500 uS 500 uS 200 uS 300 uS 500 uS 500 uS 500 uS 1000 uS 1000 uS 50 mA 120 mA 250 mA 250 mA 250 mA 50 mA 120 mA 250 mA 250 mA 250 mA 500 mA 500 mA 83 A 250 A 625 A 520 A 1150 A 83 A 250 A 625 A 520 A 1150 A 1350 A 1800 A 8 mA 8 mA 10 mA 10 mA 10 mA 10 mA 8 mA 10 mA 10 mA 10 mA 5 mA 5 mA 1.6 VAC 1.6 VAC 1.8 VAC 1.8 VAC 1.6 VAC 1.6 VAC 1.6 VAC 1.8VAC 1.8 VAC 1.8 VAC 1.8 VAC 72 72 1250 1250 5000 312 1250 1035 2600 5800 3500 312 3.2 3.2 0.2 0.14 0.14 0.5 0.2 0.14 +fan +fan 0.14 0.14 0.14 0.5 25 Hz to 70 Hz 40 mS 80 mS MISCELLANEOUS CHARACTERISTICS Dielectric Strength (Input-to Output Isolation): Insulation Resistance: Operating Temperature Range: Storage Temperature Range: Weight: 4000 V rms 1010 min. -40C to +80C -40C to +100C 10 amps to 50 amps: 100 grams approx. 75 amps to 125 amps: 250 grams approx. FEATURES * RED L. E. D. STATUS LAMP * CLEAR SAFETY COVER * UP TO 660 VAC OUTPUTS * HIGH TRANSIENT CAPABILITY-- SINGLE OUTPUT FEATURES BACK TO BACK SCR'S AND INTERNALLY MOUNTED RC (SNUBBER) NETWORK FOR HIGH DV/DT APPLICATIONS. * PHOTO-ISOLATED, ZERO VOLTAGE SWITCHING * OPTICALLY COUPLED FOR 4000 VAC ISOLATION BETWEEN INPUT AND OUTPUT AND RFI SUPPRESSION. * LIFETIME WARRANTY PART NUMBERS W6210ASX-1 *W6225ASX-1 W6240ASX-1 W6250ASX-1 W6275ASX-1 W6410ASX-1 W6425ASX-1 W6440ASX-1 W6450ASX-1 W6475ASX-1 W6690ASX-1 W66125ASX-1 . O N. T S SP SEE END OF SECTION 2 FOR CROSS REFERENCE. * CONSULT FACTORY FOR OTHER CONFIGURATIONS RATED LOAD CURRENT 10 AMPS 25 AMPS 40 AMPS 50 AMPS 75 AMPS 10 AMPS 25 AMPS 40 AMPS 50 AMPS 75 AMPS 90 AMPS 125 AMPS Approved 2...10 CLASS 6 SOLID STATE RELAY DSX SERIES SPST-N.O. 10 TO 125 AMPS DC CONTROLLED INPUT AC SCR OUTPUT L. E. D. STATUS LAMP. c us UL Recognized File No. E52197 On selected models GENERAL SPECIFICATIONS INPUT CHARACTERISTICS Control Voltage Range: Typical Input Current: Must Release Voltage: Reverse Polarity Protection: Power Indicator: OUTPUT CHARACTERISTICS Style: Load Voltage Range: Rated Load Current: Maximum Off-State Voltage dv/dt: Minimum Load Current: Non -Repetitive Surge Current (1 Cycle): Maximum off State Leakage Current (Rms): Typical On-State Voltage Drop (Rms): Maximum I2T for Fusing (A2 Sec): Suggested Heatsink C/W: Operating Frequency Range: Maximum Turn - On Time: Maximum Turn - Off Time: RED L.E.D. STATUS LAMP COMPLIES WITH REQUIREMENTS OF * IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE = INTERNATIONAL * IEC ELECTROTECHNICAL COMMISSION 3 - 32 VDC 16 mA 1 VDC Yes Red L. E. D. Status lamp W62 40 - 280 VAC 10 Amp 25 Amp 40 Amp 50 Amp 200 uS 500 uS 500 uS 500 uS 50 mA 120 mA 250 mA 250 mA 83 A 250 A 625 A 520 A 10 mA 10 mA 10 mA 8 mA 1.6 VAC 1.6 VAC 1.6 VAC1.8 VAC 625 1250 83 250 0.2 0.014 3.2 0.5 25 Hz to 70 Hz 40 mS 80 mS TESTING AND EVALUATION * CE PERFORMED BY THE UNDERWRITERS LABORATORIES AS A THIRD PARTY PARTICIPANT W64 W66 48 - 560 VAC 48 - 660 VAC 75 Amp 10 Amp 25 Amp 40 Amp 50 Amp 75 Amp 90 Amp 125 Amp 500 uS 200 uS 300 uS 500 uS 500 uS 500 uS 1000 uS 1000 uS 250 mA 50 mA 250 mA 250 mA 250 mA 250 mA 500 mA 500 mA 1150 A 83 A 250 A 625 A 520 A 1150 A 1350 A 1800 A 5 mA 10 mA 10 mA 10 mA 10 mA 10 mA 10 mA 5 mA 1.8 VAC 1.6 VAC 1.6 VAC 1.6 VAC 1.8VAC 1.8 VAC 1.8 VAC 1.8 VAC 5800 72 5000 312 1250 1035 2600 3500 0.14 0.14+fan 0.14+fan 3.2 0.14 0.5 0.2 0.14 MISCELLANEOUS CHARACTERISTICS Dielectric Strength (Input-to Output Isolation): 4000 V rms Insulation Resistance: 1010 min. Operating Temperature Range: -40C to +80C Storage Temperature Range: -40C to +100C Weight: 10 amps to 50 amps: 100 grams approx. 75 amps to 125 amps: 250 grams approx. FEATURES * RED L. E. D. STATUS LAMP * CLEAR SAFETY COVER * UP TO 660 VAC OUTPUTS * HIGH TRANSIENT CAPABILITY-- SINGLE OUTPUT FEATURES BACK TO BACK SCR'S AND INTERNALLY MOUNTED RC (SNUBBER) NETWORK FOR HIGH DV/DT APPLICATIONS. * PHOTO-ISOLATED, ZERO VOLTAGE SWITCHING * OPTICALLY COUPLED FOR 4000 VAC ISOLATION BETWEEN INPUT AND OUTPUT AND RFI SUPPRESSION. * LIFETIME WARRANTY . O N. T S SP SEE END OF SECTION 2 FOR CROSS REFERENCE 2...11 * CONSULT FACTORY FOR OTHER CONFIGURATIONS PART NUMBERS RATED LOAD CURRENT W6210DSX-1 *W6225DSX-1 W6240DSX-1 W6250DSX-1 W6275DSX-1 W6410DSX-1 W6425DSX-1 W6440DSX-1 W6450DSX-1 W6475DSX-1 W6690DSX-1 W66125DSX-1 10 AMPS 25 AMPS 40 AMPS 50 AMPS 75 AMPS 10 AMPS 25 AMPS 40 AMPS 50 AMPS 75 AMPS 90 AMPS 125 AMPS Approved CLASS 6 SOLID STATE RELAY DDX SERIES FOR D.C. SWITCHING 12 TO 40 AMPS DC CONTROLLED INPUT DC MOSFET OUTPUT L. E. D. STATUS LAMP. c us UL Recognized File No. E52197 GENERAL SPECIFICATIONS RED L.E.D. STATUS LAMP INPUT CHARACTERISTICS Control Voltage Range: Typical Input Current: Must Release Voltage: Power Indicator: OUTPUT CHARACTERISTICS Style: Load Voltage Range: Rated Load Current: Minimum Load Current: Non -Repetitive Surge Current (1 Cycle): Maximum Off State Leakage Current (Rms): Typical On-State Voltage Drop (Rms): Suggested Heatsink C/W: Maximum Turn - On Time: Maximum Turn - Off Time: 3 - 32 VDC 10 mA 1 VDC Red L. E. D. Status lamp W62 2 - 200 VDC 12 Amp 25 Amp 40 Amp 20 mA 20 mA 20 mA 90 A 27 A 50 A 8 mA 8 mA 8 mA 1.6 VAC 1.6 VAC 1.6 VAC 0.14 1.0 0.5 MISCELLANEOUS CHARACTERISTICS Dielectric Strength (Input-to Output Isolation): Insulation Resistance: Operating Temperature Range: Storage Temperature Range: Weight: 600 uS 2.6 mS 2500 V rms 1010 min. -40C to +80C -40C to +100C 100 grams approx. FEATURES * RED L. E. D. STATUS LAMP * CLEAR SAFETY COVER * UP TO 200 VDC OUTPUTS * 2500 VAC ISOLATION BETWEEN INPUT AND OUTPUT AND RFI SUPPRESSION. * LIFETIME WARRANTY . O N. T S SP PART NUMBERS W6212DDX-1 W6225DDX-1 W6240DDX-1 SEE END OF SECTION 2 FOR CROSS REFERENCE CONSULT FACTORY FOR OTHER CONFIGURATIONS RATED LOAD CURRENT 12 AMPS 25 AMPS 40 AMPS 2...12 6 CLASS SOLID STATE RELAY DTX SERIES 10 TO 40 AMPS DC CONTROLLED INPUT AC TRIAC OUTPUT L. E. D. STATUS LAMP. NORMALLY OPEN OR NORMALLY CLOSED CONTACTS. c us UL Recognized File No. E52197 GENERAL SPECIFICATIONS INPUT CHARACTERISTICS Control Voltage Range: Typical Input Current: Must Release Voltage: Reverse Polarity Protection: Power Indicator: OUTPUT CHARACTERISTICS Style: Load Voltage Range: Rated Load Current: Maximum Off-State Voltage dv/dt: Minimum Load Current: Non -Repetitive Surge Current (1 Cycle): Maximum Off State Leakage current (Rms): Typical On-State Voltage Drop (Rms): Maximum I2T for Fusing (A2 Sec): Suggested Heatsink C/W: Operating Frequency Range: Maximum Turn - On Time: Maximum Turn - Off Time: 3 - 32 VDC W62: 2 mA; W64: 16 mA 1 VDC Yes Red L. E. D. Status lamp RED L.E.D. STATUS LAMP W62 W64 48 - 480 VAC 24 - 280 VAC 10 Amp 25 Amp 40 Amp 10 Amp 25 Amp 40 Amp 250 uS 250 uS 250 uS 200 uS 250 uS 250 uS 50 mA 120 mA 50 mA 50 mA 20 mA 250 mA 100 A 250 A 250 A 100 A 250 A 250 A 10 mA 10 mA 10 mA 10 mA 10 mA 10 mA 1.6 VAC 1.6 VAC 1.6 VAC 1.6 VAC 1.6 VAC 1.6 VAC 250 438 35 200 52 300 0.2 1.4 3.2 0.5 3.2 0.5 25 Hz to 70 Hz 40 mS 80 mS MISCELLANEOUS CHARACTERISTICS Dielectric Strength (Input-to Output Isolation): 4000 V rms Insulation Resistance: 1010 Min. Operating Temperature Range: -40C to +80C Storage Temperature Range: -40C to +100C Weight: 100 grams approx. FEATURES * RED L. E. D. STATUS LAMP * CLEAR SAFETY COVER * UP TO 480 VAC OUTPUTS * HIGH TRANSIENT CAPABILITY-- SINGLE OUTPUT FEATURES TRIAC AND INTERNALLY MOUNTED RC (SNUBBER) NETWORK FOR HIGH DV/DT APPLICATIONS. * PHOTO-ISOLATED, ZERO VOLTAGE SWITCHING * OPTICALLY COUPLED FOR 4000 VAC ISOLATION BETWEEN INPUT AND OUTPUT AND RFI SUPPRESSION. * LIFETIME WARRANTY . O N. T S SP SEE END OF SECTION 2 FOR CROSS REFERENCE 2...13 CONSULT FACTORY FOR OTHER CONFIGURATIONS PART NUMBERS RATED LOAD CURRENT NORMALLY OPEN CONTACTS W6210DTX-1 W6225DTX-1 W6240DTX-1 W6410DTX-1 W6425DTX-1 W6440DTX-1 10 AMPS 25 AMPS 40 AMPS 10 AMPS 25 AMPS 40 AMPS NORMALLY CLOSED CONTACTS W6210DTX-4 10 AMPS W6225DTX-4 25 AMPS W6240DTX-4 40 AMPS CLASS 6 SOLID STATE RELAY DTX SERIES DPST-N.O. 10 AMPS DC CONTROLLED INPUT AC DOUBLE-POLE OUTPUT L. E. D. STATUS LAMP. RED L.E.D. STATUS LAMP 0.187" (4.74) QUICK CONNECT 0.250" (6.35) QUICK CONNECT c us UL Recognized File No. E52197 OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). GENERAL SPECIFICATIONS 1 6 2500 V rms 1010 -40C to +80C -40C to +100C 100 grams approx. RED L.E.D. OUTPUT MISCELLANEOUS CHARACTERISTICS Dielectric Strength (Input-to Output Isolation): Insulation Resistance: Operating Temperature Range: Storage Temperature Range: Weight: 1.750 (44.5) 2 24-280 VAC 10 amp 250 V/uSEC 50 mA 100 amp 10 mA 1.6 VAC 1 25 Hz to 70 Hz 1/2 Hz 1/2 Hz 4- OUTPUT CHARACTERISTICS Load Voltage Range: Rated Load Current: Maximum off-State Voltage dv/dt: Minimum Load Current: Non -Repetitive Surge Current (1 Cycle): Maximum Off State Leakage current (Rms): Typical On-State Voltage Drop (Rms): Suggested Heatsink C/W: Operating Frequency Range: Maximum Turn - On Time: Maximum Turn - Off Time: INPUT 3.5 - 32 VDC 2 mA 1 VDC Yes Red L. E. D. Status lamp +3 INPUT CHARACTERISTICS Control Voltage Range: Typical Input current: Must Release Voltage: Reverse Polarity Protection: Power Indicator: 5 2.250 (57.2) OUTPUT INPUT 0.800 MAX. (20.32) FEATURES * RED L. E. D. STATUS LAMP * CLEAR SAFETY COVER * UP TO 280 VAC OUTPUTS * HIGH TRANSIENT CAPABILITY-- SINGLE OUTPUT FEATURES TRIAC AND INTERNALLY MOUNTED RC (SNUBBER) NETWORK FOR HIGH DV/DT APPLICATIONS. * PHOTO-ISOLATED, ZERO VOLTAGE SWITCHING * OPTICALLY COUPLED FOR 2500 VAC ISOLATION BETWEEN INPUT AND OUTPUT AND RFI SUPPRESSION. * LIFETIME WARRANTY CONSULT FACTORY FOR OTHER CONFIGURATIONS PART NUMBERS RATED LOAD CURRENT W6210DTX-3 10 AMPS 2...14 CLASS 70S2 SOLID STATE RELAYS SPST-N.O. 2.5 TO 25 AMPS BENEFITS * EXCELLENT TRANSIENT PROTECTION * HIGH SURGE CURRENT CAPABILITY * OPTICALLY ISOLATED * HIGH BLOCKING VOLTAGE * EXTREMELY LONG LIFE * MINIATURE BUT MIGHTY; UP TO 25 AMP SWITCHING FORMERLY GRAYHILL C US UL Recognized File No. E52197 168986 TUV on Selected models DC INPUT-AC OUTPUT CONTROL VOLTAGE RANGE NOMINAL LOAD VOLTAGE 2.5 A 3A 4A 6A 6A 6A 3-30 or 6-30 VDC 3-32 or 6-32 VDC 3-30 or 6-30 VDC 3-30 or 6-30 VDC 3-30 or 6-30 VDC 3-30 or 6-30 VDC 24, 120 or 240 VAC 24, 120 or 240 VAC 24, 120 or 240 VAC 120 or 240 VAC 120 or 240 VAC 120 or 240 VAC 6A 3-30 or 6-30 VDC 120 or 240 VAC 10 A 12 A 3-30 or 6-30 VDC 3-30 or 6-30 VDC 120 or 240 VAC 120 or 240 VAC 12 A 3-30 or 6-30 VDC 120 or 240 VAC 25 A 3-30 VDC 120 or 240 VAC MAX. LOAD CURRENT DESCRIPTION AND FEATURES MINIATURE PRINTED CIRCUIT MOUNT RELAY, ONLY 0.500" HIGH SINGLE IN - LINE PACKAGE, USES ONLY 0.680 SQ. INCHES BOARD AREA COMPACT RELAY, PRINTED CIRCUIT MOUNT LOW PROFILE RELAY, PANEL OR PRINTED CIRCUIT MOUNT COMPACT RELAY, PANEL OR PRINTED CIRCUIT MOUNT COMPACT RELAY, MEETS FIT/FUNCTION REPLACEMENTS FOR LARGER CLASS 6 STYLE RELAYS, QUICK CONNECT TERMINALS COMPACT RELAY, MEETS FIT/FUNCTION REPLACEMENTS FOR LARGER CLASS 6 STYLE RELAYS, SCREW TERMINALS COMPACT RELAY, PANEL OR PRINTED CIRCUIT MOUNT 10 AMP COMPACT RELAY, MEETS FIT/FUNCTION REPLACEMENTS FOR LARGER CLASS 6 STYLE RELAYS, QUICK CONNECT TERMINALS COMPACT RELAY, MEETS FIT/FUNCTION REPLACEMENTS FOR LARGER CLASS 6 STYLE RELAYS, SCREW TERMINALS HIGH OUTPUT VERSION OF ABOVE STYLE "S" STYLE H V F L M N S M N S S DC INPUT-DC OUTPUT MAX. LOAD CURRENT CONTROL VOLTAGE RANGE NOMINAL LOAD VOLTAGE 5A 3-15 or 9-30 VDC 3-15 or 9-30 VDC 3-15 VDC 3 to 60 VDC 3 to 60 VDC 3 to 60 VDC 5A 3-15 VDC 3 to 60 VDC 3A 3A DESCRIPTION AND FEATURES SINGLE IN - LINE PACKAGE, USES ONLY 0.680 SQ . INCHES BOARD SPACE COMPACT RELAY, PRINTED CIRCUIT. MOUNT COMPACT RELAY, MEETS FIT/FUNCTION REPLACEMENTS FOR LARGER CLASS 6 STYLE RELAYS, QUICK CONNECT TERMINALS COMPACT RELAY, MEETS FIT/FUNCTION REPLACEMENTS FOR LARGER CLASS 6 STYLE RELAYS, SCREW TERMINALS ORDERING CODE FOR RELAYS 70S2- 04- D- 03 - V CLASS: CONTROLVOLTAGE: 01 = 3 - 15 VDC, DC/DC RELAYS 02 = 9 - 30 VDC, DC/DC RELAYS 03 = 3 - 30 VDC, 25 A COMPACT RELAY 04 = 3 - 30 VDC (OR 32 VDC), DC/AC RELAYS 05 = 6 - 30 VDC (OR 32 VDC), DC/AC RELAYS CONTROLVOLTAGE: A = 3-60 VDC B = 120 VAC C = 240 VAC D = 24 VAC MAX CURRENT RATING 02 = 2.5 A 04 = 4 A 06 = 6 A 03 = 3 A 05 = 5 A 10 = 10A 12 = 12 A 25 = 25 A PACKAGE STYLE F, H, L, M, N, S OR V. 2...15 CONSULT FACTORY FOR OTHER CONFIGURATIONS STYLE V F N S CLASS 70S2 SOLID STATE "V" STYLE RELAY SPST-N.O. 3 AMPS OUTLINE DIMENSIONS DC CONTROLLED INPUT AC OR DC OUTPUT. DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). c 168986 us UL Recognized File No. E52197 1.700 (43.18) TUV on Selected models Figure 1: Maximum Continuous Current vs. Ambient Temperature 1.000 (25.4) OUTPUT + INPUT + 3 OBSERVE POLARITY ON DC CONNECTIONS 0.235 0.020 5.97 0.51 2 0.300 (7.62) 1 0.400 (10.16) 0.900 (22.86) -40 -20 0 20 40 60 80 100 AMBIENT TEMPERATURE (C) 1.100 (27.94) 0.1000 (2.54) 0.400 (10.16) GENERAL SPECIFICATIONS INPUT CHARACTERISTICS Style: Control Voltage Range: Typical Input Current: Must Release Voltage: Max. Reverse Control Voltage: STYLE V 0.040 / 0.042 DIA. (O 1.04) TYP. 70S2-04-D 70S2-05-D 70S2-04-B 70S2-05-B 70S2-04-C 70S2-05-C 70S2-01-A 70S2-02-A 3 - 32 VDC 1.0 -19 mA 1.0 VDC 3 VDC 6 - 32 VDC 1.0 -6.0 mA 1.0 VDC 3 VDC 3 - 15 VDC 9 - 30 VDC 5 - 40 mA 5 - 17 mA 1.0 VDC 1.0 VDC 3 VDC 3 VDC OUTPUT CHARACTERISTICS Load Voltage Range: Rated Load Current : Maximum off-State Voltage dv/dt: Minimum Load Current: Non-Repetitive Surge Current (1 Cycle): Maximum Off State Leakage Current (Rms): Typical On-State Voltage Drop(Rms): Minimum Peak Blocking Voltage: Operating Frequency Range: Maximum Turn - On Time: Maximum Turn - Off Time: 6 - 32 VDC 1.0 -6.0 mA 1.0 VDC 3 VDC 3 - 32 VDC 1.0 -19 mA 1.0 VDC 3 VDC 3 - 32 VDC 1.0 -19 mA 1.0 VDC 3 VDC 6 - 32 VDC 1.0 -6.0 mA 1.0 VDC 3 VDC 8 - 50 VAC 8 - 50 VAC 24 -140 VAC 24-140 VAC 24-280 VAC 24-280 VAC 3-60 VDC 3 Amps 3 Amps 3 Amps 3 Amps 3 Amps 3 Amps 3 Amps 3000 V/u Sec Typ. 75 mA 75 mA 75 mA 75 mA 75 mA 75 mA 100 mA 60 Amps Peak @ 25C 3-60 VDC 3 Amps 100 mA 5 Amps/1 Sec. 3 mA 3 mA 6 mA 6 mA 6 mA 6 mA 1.6 200 V 25 to 70 Hz 8.3 mS 8.3 mS 1.6 200 V 25 to 70 Hz 8.3 mS 8.3 mS 1.6 400 V 25 to 70 Hz 8.3 mS 8.3 mS 1.6 400 V 25 to 70 Hz 8.3 mS 8.3 mS 1.6 1.6 600 V 600 V 25 to 70 Hz 25 to 70 Hz 8.3 mS 8.3 mS 8.3 mS 8.3 mS 10 uA 10 uA 1.2 VDC 105 VDC DC 75 uS 500 uS 1.2 VDC 105 VDC DC 75 uS 500 uS MISCELLANEOUS CHARACTERISTICS Dielectric Strength (Input- Output Insulation): 3750 V rms. 3750 V rms. 3750 V rms. 3750 V rms. 3750 V rms. 3750 V rms. 2500 V rms. 2500 V rms. Insulation Resistance: 1010 Min. Operating Temperature Range: -40C to +100C RATED LOAD PART Storage Temperature Range: -40C to +125C LOAD VOLTAGE NUMBERS Weight: 25 grams approx. CURRENT RANGE *70S2-04-D-03-V *70S2-05-D-03-V *70S2-04-B-03-V *70S2-05-B-03-V *70S2-04-C-03-V *70S2-05-C-03-V 70S2-01-A-03-V 70S2-02-A-03-V FEATURES * SINGLE IN LINE PACKAGE RELAY. * OPTICALLY ISOLATED. * PC MOUNT. * SWITCHES UP TO 3 AMP LOADS. * MINIMAL BOARD SPACE REQUIRED. * LIFETIME WARRANTY. CONSULT FACTORY FOR OTHER CONFIGURATIONS * TUV 8 - 50 VAC 8 - 50 VAC 24 -140 VAC 24 - 140 VAC 24 - 280 VAC 24 - 280 VAC 3 - 60 VDC 3 - 60 VDC 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 2...16 CLASS 70S2 SOLID STATE "N" & "S" STYLE RELAYS SPST-N.O. 5, 6, 12 & 25 AMPS Figure 1: Maximum Continuous Current vs. Ambient Temperature DC CONTROLLED INPUT AC OR DC OUTPUT. c us 168986 UL Recognized File No. E52197 STYLE S, 25A 25 20 15 STYLE N & S, 12A 10 STYLE N & S, 6A 5 -40 -20 0 20 40 60 80 100 AMBIENT TEMPERATURE (C) STYLE N STYLE S GENERAL SPECIFICATIONS INPUT CHARACTERISTICS Style: Control Voltage Range: Typical Input Current: Must Release Voltage: Max.Reverse Control Voltage: 70S2-04-B 3 - 30 VDC 7.0 -16 mA 1.0 VDC 3 VDC OUTPUT CHARACTERISTICS Load Voltage Range: 24-140 VAC Rated Load Current : 6 Amp 12 Amp Maximum off-State Voltage dv/dt: Minimum Load Current: 75 mA 100 mA Non-Repetitive Surge Current (1 Cycle): 60Amp 150Amp Maximum Off State Leakage Current (Rms): 6 mA Typical On-State Voltage Drop(Rms): 1.6 V Minimum Peak Blocking Voltage: 400 V Operating Frequency Range: 25 to 70 Hz Maximum Turn - On Time: 8.3 mS Maximum Turn - Off Time: 8.3 mS 70S2-05-B 6 - 30 VDC 6.0 -10 mA 1.0 VDC 3 VDC 70S2-05-C 6 - 30 VDC 6.0 -10 mA 1.0 VDC 3 VDC 70S2-03-B 3 - 30 VDC 7.0 -16 mA 1.0 VDC 3 VDC 70S2-03-C 3 - 30 VDC 7.0 -16 mA 1.0 VDC 3 VDC 70S2-01-A 3 - 15 VDC 5 - 40 mA 1.0 VDC 3 VDC 24-140 VAC 24-280 VAC 24-280 VAC 24-140 VAC 24-280 VAC 3-60 VDC 6 Amp 12 Amp 6 Amp 12 Amp 6 Amp 12 Amp 25 Amps 25 Amps 5 Amps 3000 V/u Sec Typ. 75 mA 100 mA 75 mA 100 mA 75 mA 100 mA 100 mA 100 mA 100 mA 70S2-02-A 9 - 30 VDC 5 - 17 mA 1.0 VDC 3 VDC 3-60 VDC 5 Amps 100 mA 60Amp 150Amp 60Amp 150Amp 60Amp 150Amp 300 Amps 300 Amps 7 Amps/sec 7 Amps/sec 6 mA 6 mA 6 mA 6 mA 6 mA 10 uA 1.6 V 400 V 25 to 70 Hz 8.3 mS 8.3 mS 1.6 V 600 V 25 to 70 Hz 8.3 mS 8.3 mS 1.6 V 600 V 25 to 70 Hz 8.3 mS 8.3 mS 1.7 V 400 V 25 to 70 Hz 8.3 mS 8.3 mS 1.7 V 1.85 VDC 600 V 105 VDC 25 to 70 Hz 8.3 mS 75 uS 8.3 mS 750 uS 3000 V rms. 3000 V rms. 3000 V rms. 3000 V rms. 2500 V rms. 2500 V rms. MISCELLANEOUSCHARACTERISTICS Dielectric Strength (Input- Output Insulation): 3000 V rms. 3000 V rms. Insulation Resistance : 1010 Min. Operating Temperature Range: -40C to +100C Storage Temperature Range: -40C to +125C Weight: 47 grams approx. 2...17 70S2-04-C 3 - 30 VDC 7.0 -16 mA 1.0 VDC 3 VDC CONSULT FACTORY FOR OTHER CONFIGURATIONS 10 uA 1.85 VDC 105 VDC 75 uS 750 uS CLASS 70S2 SOLID STATE "N" & "S" STYLE RELAYS SPST-N.O. 5, 6, 12 & 25 AMPS OUTLINE DIMENSIONS STYLE "S" IS NOT INTENDED FOR PC BOARD MOUNTING CONSULT FACTORY DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). 0.250 2.0 (6.35 0.51) (4) 6-32 SCREWS AND WASHERS PROVIDED 0.300 0.020 (7.62 0.51) 0.864 (21.95)MAX. 0.864 (21.95)MAX. 0.980 (24.89) MAXIMUM SCREW TORQUE = 9 IN - LBS 2.200 (55.88) 1.870 (47.50) 1.870 (47.50) 1.200 (30.48) 1.200 (30.48) 0.900 (22.86) 0.600 1.000 (15.24) (25.4) 3 2 0.400 (10.16) OUTPUT 1 INPUT OUTPUT 0.500 1.000 (12.7) (25.4) 3 1 INPUT 2 0.400 (10.16) 4 0.176 (4.47) 4 0.176 (4.47) 2 TERMINALS 0.187 (4.75) 2.200 (55.88) 0.750 (19.05) 2 TERMINALS 0.250 (6.35) 43+ + SUPPLY 2 DC INPUT 1 TERMINAL SIDE VIEW OBSERVE POLARITY ON DC CONNECTIONS STYLE N STYLE S FEATURES * * * * OPTICALLY ISOLATED. PANEL MOUNT. SWITCHES UP TO 25 AMP LOADS MOUNTS ON CLASS 6 RELAY CENTERS, YET NEEDS 1/2 THE SPACE * SCREW TERMINALS OR PUSH - ON QC TERMINALS * LIFETIME WARRANTY LOAD PART NUMBERS 70S2-04-B-06-N 70S2-05-B-06-N 70S2-04-B-12-N 70S2-05-B-12-N 70S2-04-C-06-N 70S2-05-C-06-N 70S2-04-C-12-N 70S2-05-C-12-N 70S2-04-B-06-S 70S2-05-B-06-S 70S2-04-B-12-S 70S2-05-B-12-S 70S2-03-B-25-S 70S2-04-C-06-S 70S2-05-C-06-S 70S2-04-C-12-S 70S2-05-C-12-S 70S2-03-C-25-S 70S2-01-A-05-N 70S2-01-A-05-S 70S2-02-A-05-S LOAD VOLTAGE RANGE 24 - 140 VAC 24 - 140 VAC 24 - 140 VAC 24 - 140 VAC 24 - 280 VAC 24 - 280 VAC 24 - 280 VAC 24 - 280 VAC 24 - 140 VAC 24 - 140 VAC 24 - 140 VAC 24 - 140 VAC 24 - 140 VAC 24 - 280 VAC 24 - 280 VAC 24 - 280 VAC 24 - 280 VAC 24 - 280 VAC 3 - 60 VDC 3 - 60 VDC 3 - 60 VDC RATED LOAD CURRENT 6 AMPS 6 AMPS 12 AMPS 12 AMPS 6 AMPS 6 AMPS 12 AMPS 12 AMPS 6 AMPS 6 AMPS 12 AMPS 12 AMPS 25 AMPS 6 AMPS 6 AMPS 12 AMPS 12 AMPS 25 AMPS 5 AMPS 5 AMPS 5 AMPS 2...18 CLASS 70S2 SOLID STATE "F" & "M" STYLE RELAYS SPST-N.O. 3, 4, 6 & 10 AMPS Figure 1: Maximum Continuous Current vs. Ambient Temperature DC CONTROLLED INPUT AC OR DC OUTPUT. c 14 12 10 STYLE M, 10A 8 6 STYLE M, 6A STYLE F, 4A 4 2 168986 us UL Recognized File No. E52197 -40 -20 0 20 40 60 80 100 AMBIENT TEMPERATURE (C) STYLE F STYLE M GENERAL SPECIFICATIONS INPUT CHARACTERISTICS Style: Control Voltage Range: Typical Input Current: Must Release Voltage: Max. Reverse Control Voltage: OUTPUT CHARACTERISTICS Load Voltage Range: Rated Load Current : Maximum Off-State Voltage dv/dt: Minimum Load Current: Non-Repetitive Surge Current (1 Cycle): Maximum Off State Leakage Current (Rms): Typical On-State Voltage Drop(Rms): Minimum Peak Blocking Voltage: Operating Frequency Range: Maximum Turn - On Time: Maximum Turn - Off Time: 70S2-04-B 3 - 30 VDC 7.0 -16 mA 1.0 VDC 3 VDC 70S2-05-B 6 - 30 VDC 6.0 -10 mA 1.0 VDC 3 VDC 70S2-05-C 6 - 30 VDC 6.0 -10 mA 1.0 VDC 3 VDC 70S2-01-A 3 - 15 VDC 5 - 40 mA 1.0 VDC 3 VDC 24-140 VAC 24-140 VAC 24-280 VAC 24-280 VAC 3-60 VDC 4 & 6 Amp 10 Amp 4 & 6 Amp 10 Amp 4 & 6 Amp 10 Amp 4 & 6 Amp 10 Amp 3 Amps 3000 V/u Sec Typ. 75 mA 100 mA 75 mA 100 mA 75 mA 100 mA 75 mA 100 mA 100 mA 60 Amp 110 Amp 60 Amp 110 Amp 60 Amp 110 Amp 60 Amp 110 Amp - 70S2-02-A 9 - 30 VDC 5 - 17 mA 1.0 VDC 3 VDC 3-60 VDC 3 Amps 100 mA - 6 mA 6 mA 6 mA 6 mA 10 uA 10 uA 1.6 V 400 V 25 to 70 Hz 8.3 mS 8.3 mS 1.6 V 400 V 25 to 70 Hz 8.3 mS 8.3 mS 1.6 V 600 V 25 to 70 Hz 8.3 mS 8.3 mS 1.6 V 600 V 25 to 70 Hz 8.3 mS 8.3 mS 1.2 VDC 105 VDC 75 uS 500 uS 1.2 VDC 105 VDC 75 uS 500 uS 3000 V rms 3000 V rms 2500 V rms. MISCELLANEOUS CHARACTERISTICS Dielectric Strength 3000 V rms. 3000 V rms (Input- Output Insulation): 1010 Min. Insulation Resistance: Operating Temperature Range: -40C to +100C -40C to +125C Storage Temperature Range: 35 grams approx. Weight: 2...19 70S2-04-C 3 - 30 VDC 7.0 -16 mA 1.0 VDC 3 VDC CONSULT FACTORY FOR OTHER CONFIGURATIONS 2500 V rms. CLASS 70S2 SOLID STATE "F" & "M" STYLE RELAY SPST-N.O. 3, 4, 6 & 10 AMPS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). 1.200 (30.48) 2.200 (55.88) 0.830 (21.08)MAX. 0.850 (21.59)MAX. 0.250 MIN. (6.35) 0.250 MIN. (6.35) STYLE F 1.870 (47.50) 0.600 1.000 (15.24) (25.4) STYLE M 3 2 0.400 (10.16) OUTPUT 1 INPUT 0.176 (4.47) 4 1.200 (30.48) 0.300 (7.62) 0.300 (7.62) 4 SQ. PINS 0.025 (0.64) 43+ + SUPPLY 2 DC INPUT 1 TERMINAL SIDE VIEW LOAD OBSERVE POLARITY ON DC CONNECTIONS PART NUMBERS FEATURES * OPTICALLY ISOLATED. * PANEL OR PRINTED CIRCUIT MOUNT. * SWITCHES UP TO 3, 4 , 6 OR 10 AMP LOADS. * LIFETIME WARRANTY. 70S2-04-B-04-F 70S2-05-B-04-F 70S2-04-C-04-F 70S2-05-C-04-F 70S2-04-B-06-M 70S2-05-B-06-M 70S2-04-B-10-M 70S2-05-B-10-M 70S2-04-C-06-M 70S2-05-C-06-M 70S2-04-C-10-M 70S2-05-C-10-M 70S2-01-A-03-F 70S2-02-A-03-F LOAD VOLTAGE RATED LOAD CURRENT RANGE 24 - 140 VAC 24 - 140 VAC 24 - 280 VAC 24 - 280 VAC 24 - 140 VAC 24 - 140 VAC 24 - 140 VAC 24 - 140 VAC 24 - 280 VAC 24 - 280 VAC 24 - 280 VAC 24 - 280 VAC 3 - 60 VDC 3 - 60 VDC 4 AMPS 4 AMPS 4 AMPS 4 AMPS 6 AMPS 6 AMPS 10 AMPS 10 AMPS 6 AMPS 6 AMPS 10 AMPS 10 AMPS 3 AMPS 3 AMPS 2...20 CLASS 70S2 SOLID STATE "H" & "L" STYLE RELAYS SPST-N.O. 2.5 & 6 AMPS Figure 1: Maximum Continuous Current vs. Ambient Temperature 8 7 6 5 4 3 2 1 DC CONTROLLED INPUT AC OUTPUT. STYLE L, 6A c 168986 us UL Recognized File No. E52197 STYLE H, 2.5A -40 -20 0 20 40 60 80 100 AMBIENT TEMPERATURE (C) STYLE H STYLE L GENERAL SPECIFICATIONS INPUT CHARACTERISTICS Style: Control Voltage Range: Typical Input Current: Must Release Voltage: Max. Reverse Control Voltage: 70S2-04-D 3 - 30 VDC 1.0 -17 mA 1.0 VDC 3 VDC OUTPUT CHARACTERISTICS Load Voltage Range: Rated Load Current : Maximum Off-State Voltage dv/dt: Minimum Load Current: Non-Repetitive Surge Current (1 Cycle): Maximum Off State Leakage Current (Rms): Typical On-State Voltage Drop(Rms): Minimum Peak Blocking Voltage: Operating Frequency Range: Maximum Turn - On Time: Maximum Turn - Off Time: 70S2-05-D 6 - 30 VDC 1.0 - 6.0 mA 1.0 VDC 3 VDC 70S2-04-B 3 - 30 VDC 1.0 -17 mA 1.0 VDC 3 VDC 70S2-05-B 6 - 30 VDC 1.0 - 6.0 mA 1.0 VDC 3 VDC 8 - 50 VAC 2.5 Amps 8 - 50 VAC 2.5 Amps 75 mA 75 mA 24 - 140 VAC 24 - 140 VAC 2.5 & 6 Amps 2.5 & 6 Amps 3000 V/u Sec Typ. 75 mA 75 mA 70S2-05-C 6 - 30 VDC 1.0 - 6.0 mA 1.0 VDC 3 VDC 24 - 280 VAC 2.5 & 6 Amps 24 - 280 VAC 2.5 & 6 Amps 75 mA 75 mA 60 Amps Peak Max. @ 25C 3 mA 3 mA 6 mA 6 mA 6 mA 6 mA 1.6 V 200 V 25 to 70 Hz 8.3 mS 8.3 mS 1.6 V 200 V 25 to 70 Hz 8.3 mS 8.3 mS 1.6 V 400 V 25 to 70 Hz 8.3 mS 8.3 mS 1.6 V 400 V 25 to 70 Hz 8.3 mS 8.3 mS 1.6 V 600 V 25 to 70 Hz 8.3 mS 8.3 mS 1.6 V 400 V 25 to 70 Hz 8.3 mS 8.3 mS MISCELLANEOUS CHARACTERISTICS Dielectric Strength (Input- Output Insulation): 2500 V rms. Min. Insulation Resistance: 1010 Min. Operating Temperature Range: -40C to +100C Storage Temperature Range: -40C to +125C Weight: 22 g Style H, 25 g Style L approx. 2...21 70S2-04-C 3 - 30 VDC 1.0 -17 mA 1.0 VDC 3 VDC CONSULT FACTORY FOR OTHER CONFIGURATIONS CLASS SOLID STATE "H" & "L" STYLE RELAYS 70S2 SPST-N.O. 2.5 & 6 AMPS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). 1.200 (30.48) 2.200 (55.88) 0.516 (13.1) MAX. 0.520 (13.21) MAX. 0.185 MIN. (4.74) 0.185 MIN. (4.70) 1.870 (47.50) 1.200 (30.48) 4 STYLE H 0.600 (15.24) 3 2 0.400 (10.16) OUTPUT 1 INPUT 0.176 (4.47) 0.300 (7.62) 1.000 (25.4) 0.300 (7.62) STYLE L 4 SQ. PINS 0.025 (0.64) 43+ + SUPPLY 2 DC INPUT 1 TERMINAL SIDE VIEW LOAD OBSERVE POLARITY ON DC CONNECTIONS FEATURES * OPTICALLY ISOLATED * PRINTED CIRCUIT MOUNT * SWITCHES UP TO 6 AMP LOADS * ONLY 0.5" ABOVE BOARD * MINIMAL BOARD SPACE REQUIRED * LIFETIME WARRANTY PART NUMBERS LOAD VOLTAGE RANGE 70S2-04-D-02-H 70S2-05-D-02-H 70S2-04-B-02-H 70S2-05-B-02-H 70S2-04-C-02-H 70S2-05-C-02-H 70S2-04-B-06-L 70S2-05-B-06-L 70S2-04-C-06-L 70S2-05-C-06-L 8 - 50 VAC 8 - 50 VAC 24 -140 VAC 24 -140 VAC 24 - 280 VAC 24 - 280 VAC 24 - 140 VAC 24 - 140 VAC 24 - 280 VAC 24 - 280 VAC RATED LOAD CURRENT 2.5 AMPS 2.5 AMPS 2.5 AMPS 2.5 AMPS 2.5 AMPS 2.5 AMPS 6 AMPS 6 AMPS 6 AMPS 6 AMPS 2...22 CLASS 70S2 SOLID STATE "K" STYLE RELAY SPST-N.O. 4 AMPS Figure 1: Maximum Continuous Current vs. DC CONTROLLED INPUT AC OR DC OUTPUT SOCKET MOUNTABLE Ambient Temperature c 8 7 6 5 4 3 2 1 168986 us UL Recognized File No. E52197 -40 -20 0 20 40 60 80 100 AMBIENT TEMPERATURE (C) Mating Sockets 70-459-1: SCREW/DIN See Section 8 page 13 GENERAL SPECIFICATIONS INPUT CHARACTERISTICS Style: Control Voltage Range: Typical Input Current: Must Release Voltage: Max. Reverse Control Voltage: 70S2-04-B 3 - 30 VDC 1 -17 mA 1.0 VDC 5 VDC 70S2-04-C 70S2-04-D 70S2-04-B 3 - 30 VDC 3 - 30 VDC 6 - 30 VDC 1 - 17 mA 1 -17 mA 1.0 - 6.0 mA 1.0 VDC 1.0 VDC 1.0 VDC 5 VDC 5 VDC 5 VDC OUTPUT CHARACTERISTICS Load Voltage Range: 24-140 VAC 24-280 VAC Rated Load Current : 4 Amps 4 Amps Maximum Off-State Voltage dv/dt: Minimum Load Current: 75 mA 75 mA Non-Repetitive Surge Current (1 Cycle): Maximum Off State Leakage Current (Rms): 6 mA 6 mA Typical On-State Voltage Drop(Rms): 1.6 V 1.6 V Minimum Peak Blocking Voltage: 400 V 600 V Operating Frequency Range: 25 to 70 Hz 25 to 70 Hz Maximum Turn - On Time: 8.3 mS 8.3 mS Maximum Turn - Off Time: 8.3 mS 8.3 mS 70S2-05-C 6 - 30 VDC 1.0 -17 mA 1.0 VDC 5 VDC 70S2-01-A 3 - 15 VDC 5 - 40 mA 1.0 VDC 5 VDC 70S2-02-A 9 - 30 VDC 5 -17 mA 2 VDC 5 VDC 8 - 50 VAC 24-140 VAC 24-280 VAC 8 - 50 VAC 3 - 60 VDC 3 - 60 VDC 4 Amps 4 Amps 4 Amps 4 Amps 3 Amps 3 Amps 3000 V/u Sec Typ. 75 mA 75 mA 75 mA 75 mA 100 mA 100 mA 60 Amps Peak Max. @ 25C 7 Amp-1sec 7 Amp-1sec 3 mA 6 mA 6 mA 3 mA 10 uA 10 uA 1.6 V 200 V 25 to 70 Hz 8.3 mS 8.3 mS 1.6 V 400 V 25 to 70 Hz 8.3 mS 8.3 mS 1.6 V 600 V 25 to 70 Hz 8.3 mS 8.3 mS 1.6 V 200 V 25 to 70 Hz 8.3 mS 8.3 mS 1.2 V 105 V 1.2 V 105 V 75 uS 500 uS 75 uS 500 uS MISCELLANEOUS CHARACTERISTICS Dielectric Strength (Input- Output Insulation): 3000 V rms. Min. Insulation Resistance: 1010 Min. Operating Temperature Range: -40C to +100C Storage Temperature Range: -40C to +125C Weight: 40 grams approx. 2...23 70S2-05-D 6 - 30 VDC 1 - 6.0 mA 1.0 VDC 5 VDC CONSULT FACTORY FOR OTHER CONFIGURATIONS CLASS SOLID STATE "K" STYLE RELAY 70S2 SPST-N.O. 4 AMPS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). 1.000 (25.4) 1.200 (30.48) 0.830 (21.08) 0.187 (4.74) QUICK CONNECT TERMINALS TERMINAL BOTTOM VIEW SEE NOTE 2 0.085 (2.15) 0.565 (14.35) 0.232 (5.84) 0.220 (5.58) 0.285 (7.23) 0.280 (7.11) PART NUMBERS LOAD VOLTAGE RANGE RATED LOAD CURRENT FEATURES * OPTICALLY ISOLATED * QUICK CONNECT/ SOLDER PLUG-IN MOUNT * MATES WITH 70-459-1 SOCKET * LIFETIME WARRANTY 70S2-04-B-04-K 70S2-04-C-04-K 70S2-04-D-04-K 70S2-05-B-04-K 70S2-05-C-04-K 70S2-05-D-04-K 70S2-01-A-03-K 70S2-02-A-03-K 24 - 140 VAC 24 - 280 VAC 8 - 50 VAC 24 - 140 VAC 24 - 280 VAC 8 - 50 VAC 3 - 60 VDC 3 - 60 VDC 4 AMPS 4 AMPS 4 AMPS 4 AMPS 4 AMPS 4 AMPS 3 AMPS 3 AMPS 2...24 CLASS MINIATURE SOLID STATE RELAY 226 LOAD CURRENT (AMPS) SPST-N.O. 7 AMPS THERMAL DERATING CURVE DC CONTROLLED INPUT AC OUTPUT. 8 With heat sink 3.2C/W 6 4 Free Air 2 0 10 20 30 UL Recognized File No. E52197 40 50 60 70 OUTLINE DIMENSIONS 80 DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). AMBIENT TEMPERATURE (C) 0.062 DIA (1.6) TYP. ALL PINS 0.990 TYP. (25.1) 0.340 (8.6) 0.940 MAX. (23.4) 0.990 TYP. (25.1) 0.755 MAX. (19.1) 0.600 MAX. (15.2) 0.155 (3.9) 0.600 MAX. (15.2) 0.050 (1.27) 1.500 (38.5) 1.500 (38.5) FIG. "A" FIG. "B" +5V SUPPLY 1.18 (30.2) 0.156 DIA (3.8) 2 PLACES 0.492 (12.5) INPUT 5 VDC 10 mA 0.300 670 (7.5) (17.0) +5V SUPPLY 0.92 (12.5) OUTPUT CHARACTERISTICS Load Voltage Range: Rated Load Current : Minimum Load Current: Non-Repetitive Surge Current (1 Cycle): Maximum Off State Leakage Current (Rms): Typical On-State Voltage Drop(Rms): Minimum Peak Blocking Voltage: Operating Frequency Range: Maximum Turn - On Time: Maximum Turn - Off Time: PUSH-ON TERMINAL RECEPTACLES W226RE-75 VDC 10 mA 1 VDC W226RE-812 VDC 10 mA 1 VDC 140 VAC 7 amps 50 mA 280 VAC 7 amps 50 mA 100 Amps 100 Amps MOLEX WINCHESTER 18-22 AWG 02-06-1103 156-10185 24-30 AWG 02-06-1132 156-10245 FEATURES * OPTICALLY ISOLATED. * PANEL MOUNT. * SWITCHES UP TO 7 AMP LOADS. * RANDOM VOLTAGE TURN ON. * PRINTED CIRCUIT OR PUSH ON TERMINAL PIN VERSIONS. * LIFETIME WARRANTY. 0.1 mA @ 25C 10 mA @ 65C 1.8 V 260 V 25 to 70 Hz 10 mS 60 mS 3.6 V 380 V MISCELLANEOUS CHARACTERISTICS Dielectric Strength (Input- Output Insulation): 2500 V rms. Min. Insulation Resistance: 1010 Min. Operating Temperature Range: -30C to +80C Storage Temperature Range: -40C to +100C Weight: 13 grams approx. 2...25 R1 PIN SIDE VIEW GENERAL SPECIFICATIONS INPUT CHARACTERISTICS Style: Control Voltage Range: Typical Input Current: Must Release Voltage: OUTPUT 140 OR 280 VAC UP TO 7 AMPS LOAD STANDARD TTL GATE OUTPUT + INPUT _ 0.176 (4.47) 0.200 (5.1) 0.050 (1.27) DC MIN. MAX. FIGURE CONTROLLED PULL - IN DROP-OUT INPUT PRINTED CIRCUIT TERMINALS 5 VDC W226RE-7-5A1 1.4 VDC A 4.3 VDC 12 VDC W226RE-7-12A1 2.5 VDC A 10.3 VDC 5 VDC W226RE-8-5A1 1.4 VDC A 4.3 VDC 12 VDC W226RE-8-12A1 2.5 VDC A 10.3 VDC PUSH ON TERMINALS 5 VDC W226R-7-5A1 1.4 VDC B 4.3 VDC 12 VDC W226R-7-12A1 2.5 VDC B 10.3 VDC 5 VDC W226R-8-5A1 1.4 VDC B 4.3 VDC 12 VDC W226R-8-12A1 2.5 VDC B 10.3 VDC PART NUMBERS MAX. OUTPUT CURRENT 7 AMPS 7 AMPS 7 AMPS 7 AMPS 7 AMPS 7 AMPS 7 AMPS 7 AMPS Your Contact for Relays 2 SECTION MAGNECRAFT & STRUTHERS-DUNN CROSS REFERENCE GUIDE CRYDOM CRYDOM IDEC IDEC POTTER & GORDOS BRUMFIELD OMRON OPTO OPTO 22 22 AROMAT AROMAT W6210ASX-1 A2410 - 84134001 G3NA-210B 240A10 W6225ASX-1 A2425 SSR240A25 84134011 G3NA-225B 240A25 W6240ASX-1 A2440 - - G3NA-240B W6250ASX-1 A2450 SSR240A50 84134021 - W6275ASX-1 A2475 - 84134031 - - - G3NA-410B SSR480A25 - G3NA-425B - - G3NA-440B W6410ASX-1 W6425ASX-1 HA4825 W6440ASX-1 - 240A45 W6450ASX-1 HA4850 SSR480A50 - - W6475ASX-1 HA4875 - - - - - - SSR480A125 84134181 - - 84134000 G3NA-210B AQP10A2-Z4/30VDC 240D10 SSR240D25 84134010 G3NA-225B AQP20A2-Z4/30VDC 240D25 AQP40A2-Z4/30VDC W6690ASX-1 A2490/HA4890 RSSAN-90A W66125ASX-1 A24125/HA48125 W6210DSX-1 D2410 W6225DSX-1 - D2425 W6240DSX-1 - - - G3NA-240B W6250DSX-1 D2450 SSR240D50 84134020 - W6275DSX-1 D2475 - 84134030 - W6410DSX-1 - - - G3NA-410B 480D10-12 G3NA-425B 380D25/480D25-12 240D45 W6425DSX-1 HD4825 SSR480D25 - W6440DSX-1 - - - G3NA-440B W6450DSX-1 HD4850 SSR480D50 - - W6475DSX-1 HD4875 - - - - - - SSR480D125 84134080 - SSRT240D10 84134900 SSRT240D25 84134910 W6690DSX-1 W66125DSX-1 W6210DTX-1 D2490/HD4890 RSSDN-90A - D24125/HD48125 TD2410 W6225DTX-1 380D45/480D45-12 W6212DDX-1 D1D12/D2D12 G3NA-D210B W6225DDX-1 D1D20 - W6240DDX-1 D1D40 - GORDOS CARLO CARLO GAVAZZI GAVAZZI SSR210DIN-AC 84130150 / 84130100 RN1A23A10U SSR225DIN-AC 84130152 / 84130102 RN1A23A20U MAGNECRAFT & STRUTHERS-DUNN CONTINENTAL CRYDOM RN1A60A10U SSR610DIN-AC SSR625DIN-AC RSAA-660-25-1D0 84130158 / 84130118 RN1A60A20U SSR210DIN-DC CKRD2410 84130101 RN1A23D10U SSR225DIN-DC HPF2420 / CKRD2430 84130103 RN1A23D20U CKRD4810 SSR610DIN-DC SSR625DIN-DC MAGNECRAFT & STRUTHERS-DUNN 70S2-01-A-03-V RSDA-660-25-1D0 HPF480D20/CKRD4830/HPF480D30 CONTINENTAL CONTINENTAL CRYDOM RN1A60D10U 84130116 RN1A60D20U GORDOS OPTO OPTO 22 22 ODC-05/ODC-15 DC60MP 70S2-02-A-03-V ODC-24 70S2-04-B-03-V OAC-05/OAC-15/OAC-24 MP120D3 70S2-04-C-03-V RP03-24/280-04A/OAC-05A/OAC-15A/OAC-24A MP240D3 70S2-04-C-12-N EZ240D12 70S2-05-C-12-N EZE240D12 MOAC5L/MOAC24L/MOACU MP120D2/MP120D4 GA8-6B02/GA8-6D05 MP240D2/MP120D4 Z240D10 THE CROSS REFERENCE IS INTENDED TO MATCH FOOT PRINT, INTERNAL WIRING, AND CONTACT LOAD RATINGS. CONSTRUCTION FEATURES AND GENERAL SPECIFICATIONS SHOULD BE COMPARED IF EXACT REPLACEMENT IS REQUIRED. 2...26 Your Contact for Relays SECTION MAGNECRAFT & STRUTHERS-DUNN 2 CONTINENTAL CONTINENTAL CROSS REFERENCE GUIDE CRYDOM OPTO OPTO 22 22 70S2-01-A-05-S DC60S5/DC60S7 DC60S3/DC60S5 70S2-02-A-05-S DC60S5/DC60S7 70S2-03-B-25-S D1225 120D3 70S2-04-B-06-S 120D10 70S2-04-B-12-S D1210 70S2-04-C-06-S NTD2405 240D3 70S2-04-C-12-S S505-OSJ610-000 D2410/NTD2410 240D10 70S2-03-C-25-S S505-0SJ625-000 D2425/NTD2425 120D25/240D25 THE CROSS REFERENCE IS INTENDED TO MATCH FOOT PRINT, INTERNAL WIRING, AND CONTACT LOAD RATINGS. CONSTRUCTION FEATURES AND GENERAL SPECIFICATIONS SHOULD BE COMPARED IF EXACT REPLACEMENT IS REQUIRED. FOR SOLID STATE RELAYS APPLICATION ENGINEERING ASSISTANCE Scott Heilman, PRODUCT MANAGER FAX: (843) 395-8530 EMAIL: sheilman@magnecraft.com FAX ON DEMAND: 1-800-891-2957 DOCUMENT: 500 U. S. A. TELEPHONE: FAX: WEBSITE: EMAIL: (843) 393-5778 (843) 395-4123 www.magnecraft.com info@magnecraft.com EUROPE TELEPHONE: FAX: WEBSITE: EMAIL: 2...27 4989 / 75080310 4989 / 7559344 www.magnecraft.com renatesteinback@magnecraft.de