169
COST SAVING
SUBMINATURE DIP RELAY HB-RELAYS
mm inch
UL File No.: E43028
CSA File No.: LR26550
HB
• Small size for increased packaging density
• Sensitive - Very low operating power
• Simple mechanism for stable quality - only 7 pieceparts
• DIP matching 16 pin IC socket
• Contact capacity - 1 A 125 V AC, 2 A 30 V DC
SPECIFICATIONS
Contacts
Coil
Characteristics
Arrangement
UL/CSA rating
Minimum operating power (1C) 230 mW, (2C) 370 mW
Maximum operating cycles
Initial
breakdown
voltage*2
Temperature rise
(at nominal voltage)(at 20°C)
20 cpm
Operate time*3 (at nominal voltage)
Max. 15ms (Approx. 10 ms)
Release time(without diode)*3
(at nominal voltage) Max. 8ms (Approx. 5 ms)
Initial insulation resistance*1
Between open contacts
500 Vrms
Between contact sets 500 Vrms
Between contacts and coil
1C
2C
1,000 Vrms
Max. 45°C
Max. 60°C
Min. 100 MΩ at 500 V DC
Unit weight 8 g .28 oz
Nominal operating power (1C) 360 mW, (2C) 576 mW
Mechanical 107
Electrical (resistive)
1 A 125 V AC, 2 A 30 V DC
2×105
Expected
life (min.
operations)
Max. switching power 125 VA, 60 W
Max. switching voltage
125 V AC, 30 V DC
Max. switching current
1 A AC, 2 A DC
1 A, 1/20 HP 125 V AC,
2 A 30 V DC
Rating
(resistive
load)
1 Form C, 2 Form C
Contact material
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
Gold-clad over silver-nickel
100 mΩ
Min. 98 m/s2 {10 G}
Min. 980 m/s2 {100 G}
58.8 m/s2 {6 G}, 10 to 55 Hz
at double amplitude of 1.5 mm
117.6 m/s2 {12 G}, 10 to 55 Hz
at double amplitude of 1.5 mm
–40°C to +50°C
–40°F to +122°F
Shock resistance Functional*4
Destructive*5
Functional*6
Destructive
Vibration resistance
Ambient
temp.
Humidity 5 to 85%R.H.
Conditions for operation,
transport and storage*7
(Not freezing and condens-
ing at low temperature)
Remarks
*1 Measurement at same location as “Initial breakdown voltage” section
*2 Detection current: 10mA
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 6ms; detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10µs
*7 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 49)
TYPICAL APPLICATIONS ORDERING INFORMATION
Office machines, electrical home
appliances, telecommunications
equipment, personal computers
(Note) Standard packing Carton: 100 pcs., Case: 500 pcs. or 2,000 pcs.
Ex.
Contact arrangement
1: 1 Form C
2: 2 Form C E: Amber sealed type DC 3, 5, 6, 9, 12,
24, 48 V
Type classification Coil voltage
HB 2 E DC5V