RoHS Compliant, ELV Compliant 27
4
MHP-TA Device:
MHP with Thermal Activation
Capable of handling the higher voltages and battery
discharge rates found in high-capacity LiP and
prismatic cell applications
Helps provide resettable overtemperature protection
in high-capacity LiP and prismatic cell applications
• 9VDC rating
• Two levels of current carrying capacity:
- Low current (nominal 6A hold current @25°C)
- High current (nominal 15A hold current @25°C)
• Multiple activation temperature ratings
(72°C, 77°C, 82°C, 85°C, 90°C)
• Compact size (L: 5.8mm x W: 3.85mm x H: 1.15mm)
allows for ultra-thin battery pack designs
Battery cell protection for high-capacity Lithium Polymer and prismatic cells used in:
• Media tablets
• Ultra-thin notebook PCs
• E-readers
• Smart phones
Benefits Features
Applications
The rapidly expanding market for ultra-thin portable
electronic devices, such as media tablets and ultra-thin
PCs, has created demand for very thin, low-profile, light-
weight and high-capacity Lithium Polymer (LiP) and
prismatic cells.
A new MHP (Metal Hybrid PPTC) device, the MHP-TA
device, offers a 9VDC rating and a higher current rating
than typical battery strap devices. This helps them meet
the battery safety requirements of higher-capacity LiP
and prismatic batteries found in the latest tablet and
ultra-thin computing products. Hybrid MHP technology
connects a bimetal protector in parallel with a PPTC
(polymeric positive temperature coefficient) device.
The resulting MHP-TA (Thermal Activation) series helps
provide resettable overtemperature protection, while
utilizing the PPTC device to act as a heater and to help
keep the bimetal latched until the fault is removed.
MHP-TA Device:
MHP with Thermal Activation
2013_CP_S04-CatMHP.indd 27 8/3/13 11:10 AM
RoHS Compliant, ELV Compliant
28
4
Table M2 Electrical Characteristics for the MHP-TA6 Series
Table M3 Dimensions and Mechanical Characteristics for MHP-TA Devices
Table MHP-TA: Electrical Characteristics for MHP-TA Devices
Operation Reset Reference Resistance
Rating Temperature Temperature [mohms]
[°C] [°C] [°C] 25°C
Model Number
Nominal
Min Max
Min T1
Typ
Max
MHP-TA15-9-72
72
67
77
40
7
2.5
5
MHP-TA15-9-77
77
72
82
40
10
2.5
5
MHP-TA15-9-82
82
77
87
40
10
2.5
5
MHP-TA15-9-85
85
80
90
40
10
2.5
5
MHP-TA15-9-90
90
85
95
40
10
2.5
5
Maximum breaking current 5VDC / 80A (100 cycles)
Contact Rating 9VDC / 25A (6000 cycles)
Operation Reset Reference Resistance
Rating Temperature Temperature [mohms]
[°C] [°C] [°C] 25°C
Model Number
Nominal
Min Max
Min T1
Typ
Max
MHP-TA6-9-72 72 67 77 40 7 10 15
MHP-TA6-9-77 77 72 82 40 10 10 15
MHP-TA6-9-82 82 77 87 40 10 10 15
MHP-TA6-9-85 85 80 90 40 10 10 15
Maximum breaking current 5VDC / 40A (100 cycles)
Contact Rating 9VDC / 12A (6000 cycles)
1
T is the minimum temperature differential between the actual operation temperature of the device and the reset temperature
Table M1 Electrical Characteristics for the MHP-TA15 Series
A
B C D E
Min Max Typ Min Max Min Max Min Max
mm:
10.9
11.4
1.15
3.75
3.85
2.6
2.8
2.6 2.8
0.20
0.20
0.35
D E
0.7
B
0.7
A
5.80
0.45
0.10
0.10
2.50 C
1.20
ø0.40
2013_CP_S04-CatMHP.indd 28 8/3/13 11:10 AM
RoHS Compliant, ELV Compliant 29
4
MHP-TA Device:
MHP with Thermal Activation
Figures M1-M2 Hold Current vs. Temperature Curves (Typical) for the MHP-TA6/MHP-TA15 Series
Figure M1
Figure M2
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
-15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
Current (A)
Temperature (°C)
Typical Current vs.Temperature Curves of MHP-TA15 series
A: MHP-TA15-9-72
B: MHP-TA15-9-77
C: MHP-TA15-9-82
D: MHP-TA15-9-85
E: MHP-TA15-9-90
1
2
3
4
5
6
7
8
9
10
20 25 30 35 40 45 50 55 60 65 70 75 80
Current (A)
Typical Current vs.Temperature Curves of MHP-TA6 series
A: MHP-TA6-9-72
B: MHP-TA6-9-77
C: MHP-TA6-9-82
D: MHP-TA6-9-85
Temperature (°C)
2013_CP_S04-CatMHP.indd 29 8/3/13 11:10 AM
RoHS Compliant, ELV Compliant
30
4
20°
20°
20°
20°
Physical Characteristics
Terminals Copper Alloy
Molding Plastic LCP (Liquid Crystal Polymer)
RoHS and Halogen-Free Compliance
Storage Conditions
RoHS Compliant
Halogen Free per IEC 61249-2-21
Device must be stored in the original, unopened bag.
Suggested storage temperature (except for packaging material)
Temperature: -10°C
-
40°C
Humidity: 75%RH (max)
The following environments should be avoided for storage:
Areas with salt air or with corrosive gas, such as Cl2, H2S, NH3, SO2 and NOx.
Areas exposed to direct sunlight.
Areas outside of the suggested storage temperature range, as indicated above.
The device is composed of plastic parts, please do not clamp or dent the housing with a tool as this might cause a resistance increase and
product damage.
When welding product terminals or mounting the breaker on a battery (cell), please be careful not to apply excessive bending, twisting
or force on the product and terminals. The excessive stress might cause a resistance increase or product damage.
Please refer to following cautions:
1. Do not apply more than 10N bend force to product. (Fig. M3)
2. Do not apply more than 1.5cN/m twist torque to the product. (Fig. M4)
3. Do not apply more than 20N deflection force to product. (Fig. M5)
4. Do not apply more than 2N force to the terminals. (Fig. M6)
5. Do not apply more than 0.6cN/m twisting torque to the terminals. (Fig. M7)
6. Do not bend the terminal base more than 20° when the product is mounted in a fixed position. (Fig. M8)
Product terminals can be welded using direct welding and series welding methods. In either case, please use a suitable jig so that the device
will not be subjected to the stress conditions listed above.
Pull strength and detach strength of the terminal welds are per user requirements. However, if the welding is controlled by resistance, the
measurement should be made as close as possible to the weld point by a “4-point clip method” using milliohm meter to ensure accuracy.
Avoid putting stress on the device, as listed above, when a jig, fitting or additional welding process is used. Please reconfirm the resistance
value whenever a new process is added.
Precautions for Handling
Figure M3
Figure M6
Figure M4
Figure M7
Figure M5
Figure M8
2013_CP_S04-CatMHP.indd 30 8/3/13 11:10 AM
RoHS Compliant, ELV Compliant 31
4
MHP-TA Device:
MHP with Thermal Activation
Part Number Bag Quantity
T&R Quantity Standard
Package
Part Marking Agency Recognition
MHP-TA15 Series
MHP-TA15-9-72 2,500 - 50,000 Lot ID#, Control# & Co. Logo, Product # UL 873 Recognized File No. E349829
MHP-TA15-9-77 2,500 - 50,000 Lot ID#, Control# & Co. Logo, Product # UL 873 Recognized File No. E349829
MHP-TA15-9-82 2,500 - 50,000 Lot ID#, Control# & Co. Logo, Product # UL 873 Recognized File No. E349829
MHP-TA15-9-85 2,500 - 50,000 Lot ID#, Control# & Co. Logo, Product # UL 873 Recognized File No. E349829
MHP-TA15-9-90 2,500 - 50,000 Lot ID#, Control# & Co. Logo, Product # UL 873 Recognized File No. E349829
MHP-TA6 Series
MHP-TA6-9-72 2,500 - 50,000 Lot ID#, Control# & Co. Logo, Product # UL 873 Recognized File No. E349829
MHP-TA6-9-77 2,500 - 50,000 Lot ID#, Control# & Co. Logo, Product # UL 873 Recognized File No. E349829
MHP-TA6-9-82 2,500 - 50,000 Lot ID#, Control# & Co. Logo, Product # UL 873 Recognized File No. E349829
MHP-TA6-9-85 2,500 - 50,000 Lot ID#, Control# & Co. Logo, Product # UL 873 Recognized File No. E349829
Bag 2,500 pieces
Box 50,000 pieces
Table M4 Packaging and Marking Information for MHP-TA Devices
Table M5 Ordering Information for MHP-TA Devices
2013_CP_S04-CatMHP.indd 31 8/3/13 11:10 AM
RoHS Compliant, ELV Compliant
32
4
Notice:
Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each
product selected for their own applications. Tyco Electronics Corporation and its affiliates in the TE Connectivity Ltd. group of companies
(“TE”) reserve the right to change or update, without notice, any information contained in this publication; to change, without notice, the
design, construction, processing, or specification of any product; and to discontinue or limit production or distribution of any product. This
publication supersedes and replaces all information previously supplied. Without express written consent by an officer of TE, TE does not
authorize the use of any of its products as components in nuclear facility applications, aerospace, or in critical life support devices or systems.
TE expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties
of merchantability or fitness for a particular purpose. TE’s only obligations are those in the TE Standard Terms and Conditions of Sale and in
no case will TE be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of its products.
Special Recommendations:
1. The power supply voltage must be less than the rated voltage of the device. Operation above the voltage rating may result in device
damage, smoking or flame.
2. Designs must be selected in such a manner that the device hold current is higher than the normal current value in the circuit and that the
device trip current is lower than the abnormal current value. Selecting device hold current and trip current values that are too low for the
application may interrupt the circuit under normal usage conditions.
3. This product should not be used in an application where the maximum interrupt current can be exceeded in a short circuit condition.
4. The devices are intended for protection against damage caused by occasional overcurrent or overtemperature fault conditions and should
not be used when repeated fault conditions or prolonged trip events are anticipated.
5. The devices may not perform as specified if mechanical pressure is added while the device is in the tripped state or exposed to
temperature conditions lower than -30˚C or over 100˚C.
Part Numbering System for MHP-TA Devices
MHP TA 15 9 72
Nominal Activation Temperature
Contact Voltage Rating
Nominal Hold Current at Room Temperature
Product Group
Series Name
2013_CP_S04-CatMHP.indd 32 9/3/13 3:18 PM
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
TE Connectivity:
MHP-TAM6-9-85 MHP-TAM15-9-82 MHP-TAM6-9-82 MHP-TAM15-9-72 MHP-TAM6-9-72 MHP-TAM15-9-77
MHP-TAM15-9-90 MHP-TAM6-9-77 MHP-TAM15-9-85