Pendant Stations Type BW, SKYP, and XACA Catalog 9001CT1001 2010 Class 9001 CONTENTS Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page Type BW General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Specifications and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Type XACA General Information and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . .6 Worksheet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Type SKYP General Information and Specifications . . . . . . . . . . . . . . . . . . . . . . . . .13 Worksheet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Pendant Stations Type BW Standard Duty Pendant Stations Type BW Standard Duty Pendant Stations With External Strain Relief All of the features of the Class 9001 Type BW pendant stations with external strain relief are now pre-assembled into one catalog number. * * * * * * Push button legend inserts Field-installable mushroom button Full cover gasket, to exclude harmful contaminants Jumper, included on all single speed buttons (except universal types), to save wiring time Self-lifting pressure wire connectors, for easy wiring Operator and contact sold as one unit BW90/BW100 Without External Strain Relief The Class 9001 Type BW Pendant Station is a pre-assembled, 2-button station well suited for standard hoist applications. Oversized finger grips on the rear of the enclosure make it easy to grip and operate. Features and Options BW70/BW80 * * * * * * * * * * * * Made of high impact thermoplastic with UL 94V rating (self-extinguishing flammability) NEMA 1, 3, 3R, 4, and 4X watertight, dusttight, oiltight, and corrosion resistant UL Listed and CSA approved 1/2" conduit opening Internal strain-relief post Momentary or maintained contact Single speed or two speed With or without a mechanical interlock Optional external hanger bracket and seal Ribs on the top of the enclosure to prevent the hanger bracket from rotating and coming loose Contoured for easy grip Easy to hold with one hand OFF and STOP are white letters on a red background 2 12/2010 (c) 2010 Schneider Electric All Rights Reserved Pendant Stations Specifications Specifications The Class 9001 BW70, BW80, BW90, and BW100 pendant stations are used for hoist applications requiring either single-speed or two-speed buttons. These thermoplastic enclosures have a 1/2-inch conduit entrance at the top to accept a pendant cable. Internal strain relief comes standard. The BW90 and BW100 pendant stations come with internal and external strain relief as standard. The stations are rated NEMA Type 1, 3, 3R, 4, and 4X. The enclosure is available in three colors. All universal stations have double circuit blocks (1 N.O.--1 N.C.) on each button and come without legends so they can be assembled to fit the application. For convenience, push buttons have interchangeable legend inserts. The complete line is UL listed and CSA certified. Table 1: General Specifications, Type BW Electrical Ratings AC = NEMA / UL B600; DC = NEMA / UL P600 Enclosure Type NEMA / UL Type 1, 3, 3R, 4, and 4X Operating Temperature -25 C to +60 C (-13 F to +140 F) Storage Temperature -40 C to +70 C (-40 F to +158 F) Housing Material Polycarbonate/PET Polyester Blend Approvals (R) Figure 1: File E78403 CCN NKCR File LR 25490 Class 3211 03 Marking Dimensions, Type BW 2.19 56 1.09 28 2.94 75 0.43 11 1.06 27 0.91 23 1 - 14 2 NPT 0.591 15 4.135 105 0.25 0.50 Mounting Slot 4.69 119 1/2" NPT Strain Relief Connector Dual Dimensions inches mm Table 2: Electrical Ratings DC DC--NEMA / UL P600 Volts Inductive and Resistive Make and Break Amperes Continuous Carrying Amperes 120 1.10 5 240 0.55 5 600 0.20 5 3 (c) 2010 Schneider Electric All Rights Reserved 12/2010 Pendant Stations Specifications Table 3: Electrical Contact Ratings, AC, Type BW AC--NEMA / UL B600 Inductive, 35% Power Factor Volts [1] 1 Break Make, Break, and Continuous Carrying Amperes 5 A VA A VA Continuous Carrying Amperes 120 30.0 3600 3.0 360 5 240 15.0 3600 1.5 360 5 5 480 7.5 3600 0.75 360 5 5 600 0.6 3600 0.6 360 5 5 OSHA Regulation, Section 1910.170 Overhead and Gantry Cranes, limits the voltage at pendant push buttons to 150 Vac or 300 Vdc. Table 4: Type BW90 and BW100 Pendant Stations with Cord Connector and Strain Relief Description Legend Insert Mechanical Markings Interlock BW90 / BW100 How to Order Make Resistive, 75% Power Factor Single Speed Enclosure Color Yellow Black Red Contact Symbol Replacement Interior 9001 Type Contact Symbol BOC368 146 Up-Down Yes BW92Y BW92B BW92R 146 ForwardReverse Yes BW93Y BW93B BW93R 146 BOC368 146 On-Off [1] Yes BW94Y BW94B BW94R 10 BOC358 147 Start-Stop No BW95Y BW95B BW95R 145 BOC359 25 Start-Stop [1] Yes BW96Y BW96B BW96R 10 BOC358 147 On-Off [1] No BW97Y BW97B BW97R 146 BOC359 25 Up-Down Yes -- BW98Y BW98B -- 100 -- Specify: Without Inserts Yes BW90YU BW90BU BW90RU 147 BOC366 25 * Class Number Without Inserts No BW91YU BW91BU BW91RU 25 BOC359 25 * Type Number Catalog Number: Without Inserts [1] BW94YU BW94BU BW94RU 147 BOC358 147 Class Type Without Inserts Yes BW100YU BW100BU BW100RU 150 BOC367 150 9001 BW92Y Up-Down BW102Y BW100B BW102R 150 BOC367 150 Two Speed 1 BW70 / BW80 Table 5: Type BW70 and BW80 Pendant Stations Description Legend Insert Markings Mechanical Interlock Up-Down Single Speed Specify: Class Number * Type Number Catalog Number: Class Type 9001 BW72Y Yes Maintained contact How to Order * Yes Two Speed 1 Enclosure Color Yellow Black Red Contact Symbol Replacement Interior 9001 Type Contact Symbol Yes BW72Y BW72B BW72R 146 BOC368 146 Forward-Reverse Yes BW73Y BW73B BW73R 146 BOC368 146 On-Off [1] Yes BW74Y BW74B BW74R 10 BOC358 147 Start-Stop No BW75Y BW75B BW75R 145 BOC359 25 Start-Stop [1] Yes BW76Y BW76B BW76R 10 BOC358 147 On-Off No BW77Y BW77B BW77R 146 BOC359 25 Up-Down Yes BW78Y -- -- 100 -- -- Without Legend Inserts Yes BW70YU BW70BU BW70RU 25 BOC366 25 Without Legend Inserts No BW71YU BW71BU BW71RU 25 BOC359 25 Without Legend Inserts [1] Yes BW74YU BW74BU BW74RU 147 BOC358 147 Without Legend Inserts Yes BW80YU BW80BU BW80RU 150 BOC367 150 Up-Down Yes BW82Y BW82B BW82R 150 BOC367 150 Maintained contact 4 12/2010 (c) 2010 Schneider Electric All Rights Reserved Pendant Stations Specifications Figure 2: Table 6: Contact Symbols Marking Each button has 1 N.O. contact with 4 terminals. Speed 1 100 Speed 2 10 25 Speed 1 Speed 2 145 146 147 150 Start Stop Forward Reverse Open Close Raise Lower Up Down 1 Approvals (R) Interchangeable Push Button Legend Inserts for 9001 BW Pendants, NEMA / UL Type 4X [1] Push Button Type B259 B260 B255 B256 B263 B264 B261 B262 B253 B254 Push Button Type B257 B258 B265 B266 -- B251 -- B252 -- -- Marking On Off Hand Auto -- Black -- Red -- -- Mushroom Button Type B280 B281 B288 B289 -- B251 -- B252 -- -- Order in multiples of 10. Table 7: Legend Insert Kit File E78403 CCN NKCR Where Used: File LR 25490 Class 3211 03 For NEMA Type 4X: Type BW70, BW80, BW90, and BW100 1 Mushroom Button Type B282 B283 B278 B279 B286 B287 B284 B285 B276 B277 Type [1] Push Button B250 (includes 1 each of B253 through B266) Mushroom Button B300 (includes 1 each of B276 through B289) Kit includes one each of standard legend inserts as indicated under Type of kit. Marking Table 8: Hanger Bracket [1] (Factory Installed Only on Type BW7 and BW8 ) Form Y236 1 Table 9: Strain Relief Replacement for Type BW9 and BW10 Addition of the external hanger bracket (similar to the one used on Class 9001 Type SKYP pendant stations). Use when polymeric cord connectors are required. Table 10: Hanger Bracket and Seal Kit Order Number Order Number B350 BWSR Table 11: Mushroom Button (without Button Insert) for 9001 BW Pendants, NEMA / UL Type 4X [1] Color Type Red B303 1 See page 3 for dimensions. Table 12: 9001 BW Pendant Replacement Enclosures [1] Description Yellow Red Black Box and cover with four screws BWRY BWRR BWRB 1 Screws are required. Order quantity of four, catalog no. 3110128001. 5 (c) 2010 Schneider Electric All Rights Reserved 12/2010 Pendant Stations Type XACA General Information Type XACA General Information XACA pendant stations are designed for standard- or medium-duty control circuit applications. The enclosures are made from rugged, double insulated thermoplastic material. These stations have been designed for easy handling and operation, even with heavy work gloves. Two styles of stations are offered: "small hoist" pistol grip stations with integral parts (see Table 14 on page 7), and "general purpose" station components with modular assembly required. The general purpose components are available as custom, factory-assembled stations. For custom applications, a wide range of operators, contact blocks, legend plates, and accessories are offered. Features * Single- and two-speed versions * Double insulated * Shock and corrosion resistant * 2, 4, 6, 8, 12 element versions * Ease of operation Applications * Overhead cranes * Tower cranes * Fixed hoists * Beam hoists To place a custom pendant order, use the worksheet on page 11 as a guide. Orders must be placed through the Product Selector in Quote to Cash. There is a 10% charge for assembly. Type XACA Specifications Table 13: XACA Specifications Electrical Ratings NEMA / UL A600, Q600 Enclosure XACA0 NEMA / UL Type 4, 4X (Indoor/Outdoor), 5, IP 65 XACA2 (Pistol Grip) NEMA / UL Type 4, 4X (Indoor/Outdoor), 5, IP 65 Operating Temperature -15 C to +70 C (-5 F to +158 F) Storage Temperature -40 C to +70 C (-40 F to +158 F) Housing Material Yellow polypropylene V2 Shock Resistance 100 g Vibration Resistance 15 g for 40 to 500 Hz 1 million operations XACA08 Mechanical Life Shown with optional operators and accessories. (The product life expressed is based on average usage and normal operating conditions. Actual operating life varies with conditions. The above statements are not intended to nor shall they create any express or implied warranties as to product operation or life. For information on the limited warranty offered on this product, please refer to Schneider Electric terms and conditions of sale found in the Digest.) XACA multi-element types Operating Force Cable Entry * * * With contact ZB2BE: 1 daN (36 oz.) for 1 N.O.; 1.3 daN (46.8 oz.) for 1 N.O. / 1 N.C. With contact XENG1491: 1.4 daN (50.4 oz.) for 1 N.C. / 2 N.O. With contact XENG1191: 1.4 daN (50.4 oz.) for 1st step; 2.5 daN (89.9 oz.) for 2nd step XACD: 7 to 18 mm All other models: 8 to 26 mm Screw and captive cable clamp terminals. Recommended torque 15.62 lb-in (1.8 N*m) Cabling Capacity: minimum 1 x 0.5 mm2 (20 AWG) solid or stranded; maximum, with or without cable end: 2 x 1.5 mm2 (16 AWG) or 1 x 2.5 mm2 (14 AWG) or by cable quick connector conforming to NF C 20- 20 (on request). File E164353 CCN NKCR Approvals File LR 44087 Class 3211 03 Marking (R) 6 12/2010 (c) 2010 Schneider Electric All Rights Reserved Pendant Stations Type XACA Specifications Table 14: XACA2013 Pistol Grip Stations Speeds 1 N.O. contact per operator 2 mechanically interlocked operators 1 XACA201 [1] 2 N.O. (staggered) contacts per operator 2 mechanically interlocked operators 2 XACA207 [1] 1 N.O. + 1 N.C. 2 mechanically interlocked operators 1 XACA205 [1] 1 N.O. contact per direction 1 mechanically interlocked 2 way toggle 1 XACD21A0101 1 N.O. & 1 N.C. contact per direction 1 mechanically interlocked 2 way toggle 1 XACD21A0105 1 General Purpose Pendants [1, 2] Enclosures Catalog Number 2-hole enclosure XACA02 3-hole enclosure (top hole is for E-stop only) XACA03 [3] 4-hole enclosure XACA04 6-hole enclosure XACA06 8-hole enclosure XACA08 12-hole enclosure XACA12 1 Standard enclosures include internal mounting plate, cable sleeve for 8 to 26 mm, internal cable clamp, suspension ring and cable tie. 2 Due to space limitations, two ZB2BE101 or ZB2BE102 contact blocks will fit behind each operator, but only one of any other contact block. Potentiometers will not fit in the enclosures. 3 Cannot use base-mounted items or mounting adapter. Contact Blocks for Operators in Cover [1] Table 16: XACA03 (Shown with optional operator) Description Wiring Diagram Catalog Number 1 N.O. / spring return / 1 speed -- ZB2BE101 1 N.C. / spring return / 1 speed -- ZB2BE102 1 N.O. early close, and 1 N.C. and 1 N.O. / spring return / 2 speed A XENG1191 1 N.C. and 2 N.O. / spring return / 1 speed B XENG1491 1 N.O. and 1 N.O. latching / 1 speed / interlocked C XENG3781 1 N.O. and 1 N.C. latching / 1 speed / interlocked D XENG3791 N.C. + N.C. + N.C. with positive opening operation E XENT1192 1 For mounting in enclosures: XACA03 (frontal cut-out); XACA05, A06, A08 (frontal or base cut-out). For Operators in Base of Enclosure [1] Table 17: ZB2BE10* XENG37*1 Description Catalog Number 1 N.O. / 1 speed XACS101 1 N.C. / 1 speed XACS102 2 N.O. / 1 speed XACS103 2 N.C. / 1 speed XACS104 1 N.O. and 1 N.C. / 1 speed XACS105 1 Cannot be used with XACA03 pendant. A 13 21 XENG1191 Catalog Number These XAC units are available with factory installed E-stops. Add a 3 to the end of the catalog number for the standard E-stop or add a 4 for a trigger action E-stop. E-stops include one N.C. contact block. Table 15: XACA06 Function 1 Speed / 2 Speed Description B 14 22 13 21 C 14 22 13 14 13 14 33 34 33 D 34 13 14 11 12 E 12 11 22 21 32 31 XACS10* 7 (c) 2010 Schneider Electric All Rights Reserved 12/2010 Pendant Stations Type XACA Specifications Table 18: Operators [1] Description Booted Push Button Booted push button Description Mushroom Head Mushroom head, momentary Catalog Number White XACA9411 Black XACA9412 Green XACA9413 Red XACA9414 Yellow XACA9415 Blue XACA9416 Brown XACA9419 Mushroom Color Size Catalog Number 30 mm Red ZA2BC44 30 mm Red ZA2BS44 40 mm Red ZA2BS54 30 mm Red ZA2BS834 40 mm Red ZA2BS844 30 mm Red ZA2BS74 40 mm Red ZA2BS14 40 mm Red ZA2BS844 Description Color Catalog Number Selector switch / 2 position--maintained [3] Black ZA2BD2 Selector switch / 3 position--maintained [3] Black ZA2BD3 Mushroom head, push to maintain / turn to release Mushroom head, push to maintain / turn to release (trigger action) [2] Mushroom head, push to maintain / key turn to release Selector Switch Color Mushroom head, push to maintain / key turn to release (trigger action) [2] Selector switch / 2 position--maintained key operated--key removal from left or right position [3] NA Selector Switch (Key Operated) ZA2BG4 Selector switch / 3 position--maintained key operated--key removal from left or right position [3] NA Wobble stick (bottom mounting recommended) ZA2BG5 Black ZA2BB2 Red ZA2BB4 1 Booted push buttons are for cover mounting only. All other operators can be mounted on cover or bottom. 2 Trigger action mushroom heads are tamper-proof, meaning that teasing or floating the operator does not change the contact state. 3 Not for use with XENG or XENT contact blocks. Wobble stick Table 19: Pilot Light Components Description Color Catalog Number Direct supply base without lamp (for 6-120 V applications) (AC/DC) -- ZB2BV006 Resistor supply base with 130 V lamp (for 220-240 V applications) (AC/DC) XACB961 XACA971 Pilot light operators for incandescent lamps Pilot light operators for LED lamps -- ZB2BV007 Green ZA2BV03 Red ZA2BV04 Amber ZA2BV05 Blue ZA2BV06 Clear ZA2BV07 Green ZA2BV033 Red ZA2BV043 Amber ZA2BV053 XACA982 Table 20: XACA983 Enclosure Accessories Description Catalog Number Blank hole plug ZB2SZ3 Mechanical interlock (momentary). For use with XAC booted operators only. XACA009 Screw adapter for self-supporting cable XACB961 Low suspension ring for single row station XACA971 Protective guard for bottom mounted mushroom head XACA982 Protective guard for bottom mounted selector switch or key switch XACA983 Cable sleeve (XACA20*)--pistol grip style XACA913 Cable sleeve (XACA**) XACA960 8 12/2010 (c) 2010 Schneider Electric All Rights Reserved Pendant Stations Type XACA Specifications Figure 3: Exploded View XACA960 XACB961 XENT1192 XACA941 ZA2BC4 XENG1 91 ZA2BC44 XENG371 XACA009 ZA2BS54 ZB2BE ZA2BS44 ZA2BS14 ZB2BY XACS ZB2BV00 ZA2BS74 ZB2BY ZA2BD ZA2BG XACA982 XACA971 ZA2BD ZA2BB ZA2BV0 XACA983 ZA2BG ZA2BCBS ZB2SZ3 9 (c) 2010 Schneider Electric All Rights Reserved 12/2010 Pendant Stations Type XACA Specifications Table 21: Lamps Type DL1CE0** (Incandescent) Replacement Bulbs Type BA9s Incandescent Type DL1CJUS**** (LED) LED, BA9s Base for Direct Supply Blocks Table 22: Voltage (AC/DC) Watts Catalog Number 6 1.2 DL1CB006 12 2.0 DL1CE012 24 2.0 DL1CE024 48 2.4 DL1CE048 130 2.6 DL1CE130 Color Voltage Catalog Number Green 6 Vac/Vdc DL1CJUS0063 Red 6 Vac/Vdc DL1CJUS0064 Amber 6 Vac/Vdc DL1CJUS0065 Green 12 Vac/Vdc DL1CJUS0123 Red 12 Vac/Vdc DL1CJUS0124 Amber 12 Vac/Vdc DL1CJUS0125 Green 24 Vac/Vdc DL1CJUS0243 Red 24 Vac/Vdc DL1CJUS0244 Amber 24 Vac/Vdc DL1CJUS0245 Green 120 Vac/Vdc DL1CJUS1203 Red 120 Vac/Vdc DL1CJUS1204 Amber 120 Vac/Vdc DL1CJUS1205 PVC Standard Legend Plates 30 x 40 mm Catalog Number Text [1] Catalog Number Bridge Forward ZB2BY2343 Off ZB2BY2312 Bridge Reverse ZB2BY2344 On ZB2BY2311 Close ZB2BY2314 Off On ZB2BY2367 Down ZB2BY2308 Open ZB2BY2313 Emergency Stop ZB2BY2330 Open Close ZB2BY2376 Fast ZB2BY2328 Open-O-Close ZB2BY2388 Forward ZB2BY2305 Out ZB2BY2339 For Rev ZB2BY23 Power On ZB2BY2326 For-O-Rev ZB2BY2384 Raise ZB2BY2335 Hand Off Auto ZB2BY2387 Reset ZB2BY2323 High ZB2BY2338 Reverse ZB2BY2306 High Low ZB2BY2369 Right ZB2BY2309 Hoist Down ZB2BY2342 Run ZB2BY2334 Hoist Up ZB2BY2341 Slow ZB2BY2327 In ZB2BY2503 Start ZB2BY2303 Inch ZB2BY2321 Stop ZB2BY2304 Jog For ZB2BY2381 Stop Start ZB2BY2366 Jog Rev ZB2BY2380 Trolley Right ZB2BY2345 Jog Run ZB2BY2365 Trolley Left ZB2BY2346 Left ZB2BY2310 Up ZB2BY2307 Low ZB2BY2336 Up Down ZB2BY2370 Lower ZB2BY2337 Up-O-Down ZB2BY2389 Man Auto ZB2BY2372 Text 1 [1] All nameplates are black with white lettering except "Stop", "Emergency Stop", and "Reset," which are red with white lettering. For black "Reset," change the final digit of the catalog number to 2. Table 23: PVC Blank or Custom Engraved Legend Plates, 30 x 40 mm Type PVC Blank Legend PVC Custom Engraved [1] 1 Description Catalog Number Black or red background ZB2BY2101 Yellow or white background ZB2BY4101 Black background, white letters ZB2BY2002 Red background, white letters ZB2BY2004 White background, black letters ZB2BY4001 Yellow background, black letters ZB2BY4005 Please specify lettering when ordering. Maximum of two lines with 11 characters on each line (including spaces). 10 12/2010 (c) 2010 Schneider Electric All Rights Reserved Pendant Stations Type XACA Worksheet Type XACA Worksheet Use this worksheet to assist in component selection. Custom orders for XACA pendant stations must be placed through the Product Selector in Quote to Cash. There is a 10% charge for assembly. XACA Order Guide Instructions 14 Custom built pendant stations 1. Determine the number of operators needed, then choose an enclosure with a corresponding number of holes. 2. Select the type of operator, contact block, and appropriate nameplate for each function required. Refer to pages 7-10. 3. Check for special functions that may be required. These items could include mechanical interlocks, adapters for self-supporting cable, lower support rings, protective guards, etc. Catalog number of enclosure 1 2 3 4 5 6 7 8 9 10 11 12 Mechanical interlock (draw a vertical line between the 2 units to be interlocked [1]) Functions (optional) XACA Legends Contact blocks and pilot light bodies Push button Pilot light or Blanking plug 1 2 3 4 5 13 6 15 7 8 16 9 10 17 11 12 Mechanical Interlock (XACA009) 1 1 1 2 2 3 4 3 4 1 Mechanical interlock XACA009 Number of XACA009 required Unit mounted in base of station (facing downwards) 13 2 3 4 Attachments Position Type Catalog No. 14 Adapters for self-supporting cable type BBAP (available only with cable sleeve O8-26 mm) XACB961 5 5 5 15 Lower support ring XACA971 6 6 6 16 Protective guard for base mounted selector switch or 40 mm emergency-stop push button XACA982 Impossible Combinations 17 Protective guard for key switch XACA983 Possible Combinations 11 (c) 2010 Schneider Electric All Rights Reserved 12/2010 Pendant Stations Type XACA Dimensions Type XACA Dimensions Small Hoist Type XACA201, A205, and A207 General Purpose Type XACA**** Internal dia. 8 to 10 mm Internal dia. 9 to 13 mm 11 to 14 mm 15 to 17 mm 18 to 22 mm 8.5 216 10.87 276 22 to 26 mm 1.9 48 A 1.66 42 1.8 30 1.97 50 B 2.36 60 Small Hoist XACD Internal dia. 7 to 9 mm 10 to 12 13 to 15 16 to 18 8 mm dia. 2.75 70 11.83 300.5 3.55 90 3.15 80 1.3 33 9.45 240 XAC A982 .35 8 1.1 28 3.15 80 XAC A983 2.25 57 3.23 .79 20 3.58 91 XAC A971 82 3.97 101 3.15 80 Number of Holes Dimension 2 3 4 6 8 12 in. mm in. mm in. mm in. mm in. mm in. mm A 15.00 380 15.00 380 17.33 440 19.70 500 22.10 560 26.78 680 B 7.50 190 7.50 190 9.85 250 12.20 310 14.57 370 19.30 490 12 12/2010 (c) 2010 Schneider Electric All Rights Reserved Pendant Stations Type SKYP General Information Type SKYP General Information Lifetime Enclosure Warranty This line of pendant stations consists of polymeric enclosures (2-10 units), push button units (1-5 speed), and laminated legend plates. All enclosures have an extra single-unit space near the top that permits the installation of a toggle switch, a Type SK operator or pilot light, or a warning label (see Table 29 on page 14). All enclosures come standard with a stainless-steel hanger bracket and internal strain-relief post. The enclosures are yellow with a threaded opening in the top. The complete line is UL Listed and CSA certified, with NEMA Type environmental ratings 1, 2, 3, 3R, 4, 4X, and 12 (NEMA 4 only with legend plates installed). To ensure Type 4X and 13 integrity, use only Type 4X and 13 operators or closing plates. There is a 10% charge for assembly. To place a custom pendant order, use the worksheet on page 17 as a guide. Orders must be placed through the Product Selector in Quote to Cash. Type SKYP Specifications Table 24: Type SKYP Specifications Electrical Ratings Types SKRU2-SKRU5: AC = NEMA / UL B300; DC = NEMA / UL P600 Types SKRU1, 10, 11: AC = NEMA / UL A600: DC = NEMA / UL P600 Enclosure Type UL Type 1, 2, 3, 3R, 4, 4X, 12, and 13 Operating Temperature -30 C to +60 C (-13 F to +140 F) Storage Temperature -40 C to +70 C (-40 F to +158 F) Housing Material Polycarbonate Cable Entry 1/2" NPT Approvals (R) Table 25: File E78403 CCN NKCR File LR 25490 Class 3211 03 Electrical Contact Ratings (Types SKRU2 through SKRU5) AC--NEMA / UL Type B300 Inductive, 35% Power Factor Volts [1] 1 Make Break A VA 120 30 240 15 Resistive, 75% Power Factor Continuous Carrying Amperes Make, Break, and Continuous Carrying Amperes 360 5 5 360 5 5 A VA 3600 3 3600 1.5 OSHA Regulation, Section 1910.170 Overhead and Gantry Cranes, limits the voltage at pendant push buttons to 150 Vac or 300 Vdc. Table 26: Electrical Contact Ratings (Types SKRU1, 10, and 11) AC--NEMA / UL Type A600 Inductive, 35% Power Factor Volts 1 DC--Standard Duty, NEMA / UL Type P600 Resistive, 75% Power Factor [1] Inductive and Resistive Volts Continuous Carrying Amperes Make Amperes Break Amperes Continuous Carrying Amperes Make, Break, and Continuous Carrying Amperes 120 60 6 10 10 120 1.1 10 240 30 3 10 10 240 0.55 10 480 15 1.5 10 10 -- -- -- 600 12 1.2 10 10 600 0.2 10 Make and Break Amperes OSHA Regulation, Section 1910.170 Overhead and Gantry Cranes, limits the voltage at pendant push buttons to 150 Vac or 300 Vdc. 13 (c) 2010 Schneider Electric All Rights Reserved 12/2010 Pendant Stations Type SKYP Specifications Table 27: Hanger bracket (Catalog no. 65091-061-01) Threaded conduit hole Space for toggle switch, a Type SK operator, or a pilot light. Use appropriate legend plates. Type SKYP enclosure Figure 4: Button Size Conduit Entrance Size Enclosure Only [1, 2] 2 3/4"-14 NPT SKYP2 4 3/4"-14 NPT SKYP4 6 1"-111/2 NPT SKYP6 8 11/4"-111/2 NPT SKYP8 10 11/4"-111/2 NPT SKYP10 Class 9001 SK push-to-test pilot lights, remote-test pilot lights, and potentiometers do not fit in these enclosures. 2 Assembled pendant stations consist of an enclosure, operators, and legend plates. The price of the total station consists of the prices of the individual components, plus a 10% charge for assembly. To place a custom pendant order, use the worksheet on page 17 as a guide. Orders must be placed through the Product Selector in Quote to Cash. Type SKN2 legend plate Table 28: SPEED POSITION OFF 2 1 1 2 1 Terminals C 1 1 2 2 87 SPEED POSITION OFF 3 2 1 1 2 3 Terminals C C 1 1 2 2 3 3 Push Button Units (2 Buttons per Unit) Description Contact Symbol (Figure 4) Type [1] Single Speed-- Momentary, Interlocked 7 SKRU1 Single Speed-- Momentary, Non-Interlocked 5 SKRU10 Single Speed-- Maintained, Interlock 10 SKRU11 87 SKRU2 88 SKRU3 89 SKRU4 90 SKRU5 Two Speed-- Momentary, Interlocked Three Speed-- Momentary, Interlocked Four Speed-- Momentary, Interlocked Five Speed-- Momentary, Interlocked 2868-D30 Terminals Type Type SKRU1 through SKRU11 operators. Any Type SK pilot light or operator can be mounted in this enclosure. The enclosure depth accommodates one Type KA1 through KA6 contact blocks (total of two). Multispeed Contact Symbols (X = Contact Closed) Terminals C Enclosures 1 Types SKRU 1, 10, and 11 include Type KA contact blocks. Types SKRU 2-5 are factory enclosed contact blocks. Boot for SKRU 2-5 = 9001KU37; boot for SKRU 1, 10, 11 = 9001KU1 Table 29: Legend Plates 2868-D29 88 Terminals C SPEED POSITION OFF 4 3 2 1 1 2 3 4 Where Used Marking Type For SKRU1 through SKRU11 Blank-Blank Hoist: Up-Down Trolley: East-West Trolley: Fwd.-Rev. Trolley: North-South Bridge: Fwd.-Rev. Bridge: East-West Bridge: North-South Start-Stop Reset-Stop Aux Hoist: Up-Down Power: On-Off Specify Marking SKN200 [1] SKN201 SKN202 SKN203 SKN204 SKN205 SKN206 SKN207 SKN208 SKN209 SKN210 SKN211 SKN299 [1] With Toggle Switch [2] in Top Space of Enclosure Blank Off-On On-Off Specify Marking SKN500 SKN544 SKN545 SKN599 Terminals C 1 1 2 2 3 3 4 4 2868-D31 89 Terminals C SPEED POSITION OFF 1 2 3 4 5 5 4 3 2 1 Terminals C 1 1 2 2 3 3 4 4 Blank On Off With Type SK Operator Emerg. Stop or Pilot Light [4] in Top Space Run of Enclosure Power On Off-On Specify Marking 5 5 2868-D32 90 Single Speed Contact Symbols Closing Plate Type SK52 [3] [3] [3] [3] SKN100 [5] SKN103 SKN104 SKN105 SKN124 SKN138 SKN144 SKN199 [5] 1 Maximum of 19 characters on each side. Available as Class 9001 Type SKSTS1--includes boot for NEMA Type 4X. 3 Includes legend plate, gasket, and ground plate to be used with toggle switch. 4 See Class 9001 Type SK on page 17. 5 Tri-laminated legend plate with a yellow or red background on a black core. 2 7 5 10 14 12/2010 (c) 2010 Schneider Electric All Rights Reserved Pendant Stations Type SKYP Specifications Table 30: Non-Illuminated and Illuminated Push Buttons Non-Illuminated Illuminated Description Color 2 Position 1 Color Code Catalog No. Red R Maintained Pull Red [1] R Maintained Push Black Red Green Blue Yellow White Orange Clear Amber B R G L Y W S C A Description Color Color Code Voltage Catalog No. SKR9R 2 Position Red R 120 Vac/Vdc SKR9P58R Full Voltage SKR9R05 Maintained Pull Red [1] R 24 Vac/Vdc Full Voltage SKR9P55R05 Maintained Push Black Red Green Blue Yellow White Orange Clear Amber -- R G L Y -- S C A 24 Vac/Vdc Full Voltage SKR9P55 SKR9 Red knob available with "Push Emergency Stop" printed on the red knob. See Table 36 footnote for additional options. Table 31: Pilot Lights--UL Types 4, 4X, 13/NEMA 4, 4X, and 13 Description 9001SKP1 Voltage Style With Red With Green Fresnel Color Cap Fresnel Color Cap With Other Color Cap Without Color Cap SKP1 110-120 V, 50-60 Hz Transformer SKP1R31 SKP1G31 SKP1 [1] 220-240 V, 50-60 Hz Standard Pilot Light 24-28 Vac/Vdc (Fresnel color cap shown) See Table 32 for other voltages. Transformer SKP7R31 SKP7G31 SKP7 [1] SKP7 Full Voltage SKP35R31 SKP35G31 SKP35 [1] SKP35 SKP_R31 [3] SKP_G31 [3] SKP_ [1] [3] SKP [3] [3] [3] [1] [3] SKP [3] Transformer or LED [2] Full Voltage or Resistor SKP_R31 1 Add the color code from Table 33. Example: SKP1 with an amber color Fresnel cap = SKP1A31. 2 The cap must be the same color as the LED light module, e.g., use a green color cap for a green LED. 3 See Table 32 for voltage assembly code. Table 32: SKP_G31 SKP_ Standard Light Modules for Pilot Lights Rating Type Voltage Assembly Code KM40 40 -- None Light Module Voltage Description All Full Voltage (without Bayonet Base Lamp) Replacement Lamp Catalog No. 6 Vac/Vdc Full Voltage KM31 31 0.9 VA 2550101020 6 Vac/Vdc LED Red KM31LR 31LR -- 6508805201 6 Vac/Vdc LED Green KM31LG 31LG -- 6508805203 6 Vac/Vdc LED Yellow KM31LY 31LY -- 6508805202 12-14 Vac/Vdc Full Voltage KM32 32 1.2 VA 2550101037 12-14 Vac/Vdc LED Red KM32LR 32LR -- 6508805201 12-14 Vac/Vdc LED Green KM32LG 32LG -- 6508805203 12-14 Vac/Vdc LED Yellow KM32LY 32LY -- 6508805202 24-28 Vac/Vdc Full Voltage KM35 35 1.2 VA 2550101002 24-28 Vac/Vdc LED Red KM35LR 35LR 0.28 VA 6508805210 24-28 Vac/Vdc LED Green KM35LG 35LG 0.28 VA 6508805212 24-28 Vac/Vdc LED Yellow KM35LY 35LY 0.28 VA 6508805211 24-28 Vac/Vdc LED White KM35LW 35LW 0.28 VA 6508805214 24-28 Vac/Vdc LED Blue KM35LL 35LL 0.28 VA 6508805213 110-120 V, 50-60 Hz LED Red KM1LR 1LR -- 6508805201 110-120 V, 50-60 Hz LED Green KM1LG 1LG -- 6508805203 110-120 V, 50-60 Hz LED Yellow KM1LY 1LY -- 6508805202 110-120 V, 50-60 Hz Transformer KM1 1 2.4 VA 2550101020 110-120 V, 50-60 Hz Flashing KMF1 F1 0.85 VA 2550101036 120 Vac/Vdc Resistor KM38 38 3.0 VA 2550101027 120 Vac/Vdc Full Voltage KM38 38 3.0 VA 2550101027 120 Vac/Vdc LED Red KM38LR 38LR 1.4 VA 6508805210 120 Vac/Vdc LED Green KM38LG 38LG 1.4 VA 6508805212 Continued on next page 15 (c) 2010 Schneider Electric All Rights Reserved 12/2010 Pendant Stations Type SKYP Specifications Table 32: Standard Light Modules for Pilot Lights (continued) Rating Type Voltage Assembly Code KM40 40 -- None Light Module Voltage Description Full Voltage (without Bayonet Base Lamp) All Replacement Lamp Catalog No. 120 Vac/Vdc LED Yellow KM38LY 38LY 1.4 VA 6508805211 120 Vac/Vdc LED White KM38LW 38LW 1.4 VA 6508805214 120 Vac/Vdc LED Blue KM38LL 38LL 1.4 VA 6508805213 220-240 V, 50-60 Hz Transformer KM7 7 2.0 VA 2550101020 220-240 V, 50-60 Hz LED Red KM7LR 7LR -- 6508805201 220-240 V, 50-60 Hz LED Green KM7LG 7LG -- 6508805203 220-240 V, 50-60 Hz LED Yellow KM7LY 7LY -- 6508805202 Table 33: Color Caps Table 34: Plastic Fresnel Plastic Domed A31 A9 Clear C31 C9 Green G31 G9 Red R31 R9 Yellow Y31 Y9 Symbol1 Description Color Amber Contact Blocks 1 Catalog Number Clear Color Cover KA1 Red Color Cover KA3 Both N.C. contacts are direct opening. Shallow Depth Light Modules For Type SK Control Units UL Listed and CSA certified LED light modules use a lamp with a 7-element LED cluster that provides illumination similar to incandescent illumination. With LED light modules, use either a clear color cap or a cap with the same color as the LED. Table 35: Shallow Depth Light Modules For Type SK Control Units Voltage Description 24-28 Vac/Vdc 110-120 Vac/Vdc 120 240 480 600 1 All 9001 SK All 9001 SK Light Module Type No. Voltage Rating Assembly Code (VA) KM55 KM55LR KM55LG KM55LY KM58 KM58LR KM58LG KM58LY 55 55LR 55LG 55LY 58 58LR 58LG 58LY 1.2 0.5 0.5 0.5 3.0 0.5 0.5 0.5 Replacement Lamps ANSI No. Catalog No. 2550101002 6508805204 757 6508805206 6508805205 2550101027 6508805204 120MB 6508805206 6508805205 Maximum Current Ratings For Control Circuit Contacts: Types KA1-KA6, KA21-25, KA31-35, KA1G-KA6G [1] Table 36: Volts Full Voltage LED Red LED Green LED Yellow Full Voltage LED Red LED Green LED Yellow For Use With Single Lamp Ill. Operators as Indicated AC Inductive (NEMA / UL Type A600), 35% Power Factor Make Break Continuous Carrying Amperes VA Amperes VA Amperes 60 30 15 12 7200 7200 7200 7200 6.0 3.0 1.5 1.2 720 720 720 720 10 10 10 10 Resistive, 75% Power Factor Make, Break, and Continuous Amperes 10 10 10 10 Volts KA1 125 250 -- 600 0.55 0.27 -- 0.10 DC Inductive and Resistive (NEMA Q600) Make and Break Continuous Carrying KA2 KA5 KA4 Amperes KA3 KA6 0.55 -- -- 2.5 0.27 -- -- 2.5 -- -- -- -- 0.10 -- -- 2.5 For additional Type SK push button operators (illuminated and non-illuminated), light modules, and contact blocks, see catalog 9001CT9601, Push Button and Operator Interface Specifiers Guide. All illuminated push button operators must use a shallow depth light module listed above. Only standard pilot lights and non-illuminated selector switches can be used in Type SKYP enclosures. 16 12/2010 (c) 2010 Schneider Electric All Rights Reserved Pendant Stations Type SKYP Worksheet Type SKYP Worksheet Control Products Use this worksheet to assist in component selection. SKYP Custom Pendant orders must be placed through the Product Selector in Quote to Cash. There is a 10% charge for assembly. Class 1. Operator or Closing Plate. Example: SKRU1 9001 Type Type Number Key 2. Legend Plate Type Number Example: SKN201 When the operator and the legend plate use 2 adjacent holes, specify the same catalog numbers in both locations. Example: 3. Legend Plate Marking Used Only if Special Marking is Required Example: Line 2 = SKN299 Line 3 = A.) Hoist B.) FWD C.) REV 1 SKRU1 2 SKN201 3 B A 1 SKRU1 2 SKN201 3 C 3 1 2 3 Space for a toggle switch , a Type SK operator or pilot light, or a warning label. Use SKN5 or SKN1 legend plates. A) B) C) 1 3 A) B) C) Space for toggle switch , a Type SK operator or pilot light, or a warning label. Use SKN5 or SKN1 legend plates. Conduit Entrance Size Enclosure for Assembled Station 2 3/4" -14 NPT SKYP20 4 3/4" -14 NPT SKYP40 6 1" -14 NPT SKYP60 Type SKYP enclosure Type SKRU1 through SKRU11 operators. Type 11/4" -111/2 SKYP80 10 11/4" -111/2 SKYP100 Assembled pendant stations consist of an enclosure, operators, and legend plates. The price of the total station consists of the price of each individual component plus a 10% charge for assembly. Push Button Units--NEMA / UL 4X, 13 Type SKN2 legend plate 2 3 A) B) C) Number of Buttons per Unit Description 2 Single Speed-- Momentary, Interlocked 7 SKRU1 2 Single Speed-- Momentary, Non-Interlocked 5 SKRU10 2 Single Speed-- Maintained, Interlocked 10 SKRU11 2 Two Speed-- Momentary, Interlocked 87 SKRU2 Three Speed-- Momentary, Interlocked 88 SKRU3 2 Four Speed-- Momentary, Interlocked 89 SKRU4 2 Five Speed-- Momentary, Interlocked 90 SKRU5 3 For SKRU1 through SKRU11 With Toggle Switch in Top Space of Enclosure With Type SK Operator or Pilot Light in Top Space of Enclosure Marking Type Blank-Blank Hoist: Up-Down Trolley: East-West Trolley: Fwd.-Rev. Trolley: North-South Bridge: Fwd.-Rev. Bridge: East-West Bridge: North-South Start-Stop Reset-Stop Specify Marking SKN200 SKN201 SKN202 SKN203 SKN204 SKN205 SKN206 SKN207 SKN208 SKN209 SKN299 Blank Off-On On-Off Specify Marking SKN500 SKN544 SKN545 SKN599 Blank On Off Emerg. Stop Run Power On Off-On Specify Marking Specify Marking (Red Background) SKN100 SKN103 SKN104 SKN105 SKN124 SKN138 SKN144 SKN199 SKN199R A) B) C) 1 2 3 Type 2 2 A) B) Legend Plates--NEMA / UL 4X, 13 Where Used Contact Symbol 1 1 8 SK52 2 Threaded conduit hole Button Size Type 1 2 Hanger bracket Enclosures--NEMA 4X, 13 CLOSING PLATE SKYP -________ C) 1 2 3 A) B) Type SKRU1 through SKRU 11 operators or Type SK operators and Type SKN2 legend plate. C) 1 2 3 A) B) C) 1 2 Available as 9001SKSTS1 Includes legend plate, gasket, and ground plate to be used with toggle switch. Tri-laminated legend plate with a yellow or red background on a black core. 19 characters each side. Class 9001 Type SK push-to-test pilot lights and remote test pilot lights will not fit in these enclosures. 3 A) B) C) 1 2 3 A) B) C) 1 2 3 A) B) C) 17 (c) 2010 Schneider Electric All Rights Reserved 12/2010 Pendant Stations Type SKYP Dimensions Type SKYP Dimensions Class 9001 Type SK push-to-test pilot lights and remote-test pilot lights and potentiometers do not fit in these enclosures. Standard pilot lights do fit in these enclosures. For illuminated operators in the SKYP pendant station, the shallow depth light module (9001KM55 or 9001KM58) must be used. Figure 5: Type SKYP Dimensions A See Table 34 for NPT Size 3.19 81 2.15 54.48 4.38 111 2.32 59 2.12 54 4.79 122 4.00 102 7.37 187 4.33 110 2.68 68 3.49 89 3.31 84 3.50 89 Dual Dimensions inches mm Table 37: 2.04 52 Approximate Dimensions Number of Holes Per Unit Dimension A Conduit Opening in. mm NPT 2 11.70 297 3/4" -14 4 16.03 407 3/4" -14 6 20.36 517 1" -11 1/2 8 24.69 627 11/4" -111/2 10 29.02 737 11/4" -111/2 18 12/2010 (c) 2010 Schneider Electric All Rights Reserved Pendant Stations Type SKYP Dimensions INDEX 2550101002 . . . . 15-16 2550101020 . . . . 15-16 2550101027 . . . . 15-16 2550101036 . . . . . . . .15 2550101037 . . . . . . . .15 6508805201 . . . . 15-16 6508805202 . . . . 15-16 6508805203 . . . . 15-16 6508805204 . . . . . . . .16 6508805205 . . . . . . . .16 6508805206 . . . . . . . .16 6508805210 . . . . . . . .15 6508805211 . . . . 15-16 6508805212 . . . . . . . .15 6508805213 . . . . 15-16 6508805214 . . . . 15-16 BW70 . . . . . . . . . . . . . .2 BW90 . . . . . . . . . . . . . .2 DL1CB006 . . . . . . . . .10 DL1CE012 . . . . . . . . .10 DL1CE024 . . . . . . . . .10 DL1CE048 . . . . . . . . .10 DL1CE130 . . . . . . . . .10 DL1CJUS0063 . . . . . .10 DL1CJUS0064 . . . . . .10 DL1CJUS0065 . . . . . .10 DL1CJUS0123 . . . . . .10 DL1CJUS0124 . . . . . .10 DL1CJUS0125 . . . . . .10 DL1CJUS0243 . . . . . .10 DL1CJUS0244 . . . . . .10 DL1CJUS0245 . . . . . 10 DL1CJUS1203 . . . . . 10 DL1CJUS1204 . . . . . 10 DL1CJUS1205 . . . . . 10 KA1 . . . . . . . . . . . . . . 16 KA3 . . . . . . . . . . . . . . 16 SKR9 . . . . . . . . . . . . . 15 SKR9P55 . . . . . . . . . 15 SKR9P55R05 . . . . . . 15 SKR9P58R . . . . . . . . 15 SKR9R . . . . . . . . . . . 15 SKR9R05 . . . . . . . . . 15 XACA009 . . . . . . . . . . 8 XACA02 . . . . . . . . . . . 7 XACA03 . . . . . . . . . . . 7 XACA04 . . . . . . . . . . . 7 XACA06 . . . . . . . . . . . 7 XACA08 . . . . . . . . . . . 7 XACA12 . . . . . . . . . . . 7 XACA201 . . . . . . . . . . 7 XACA205 . . . . . . . . . . 7 XACA207 . . . . . . . . . . 7 XACA913 . . . . . . . . . . 8 XACA9411 . . . . . . . . . 8 XACA9412 . . . . . . . . . 8 XACA9413 . . . . . . . . . 8 XACA9414 . . . . . . . . . 8 XACA9416 . . . . . . . . . 8 XACA9419 . . . . . . . . . 8 XACA960 . . . . . . . . . . 8 XACA971 . . . . . . . 8, 11 XACA982 . . . . . . . .8, 11 XACA983 . . . . . . . .8, 11 XACB961 . . . . . . . .8, 11 XACD21A0101 . . . . . . 7 XACD21A0105 . . . . . . 7 XACS101 . . . . . . . . . . . 7 XACS102 . . . . . . . . . . . 7 XACS103 . . . . . . . . . . . 7 XACS104 . . . . . . . . . . . 7 XACS105 . . . . . . . . . . . 7 XENG1191 . . . . . . . . . . 7 XENG1491 . . . . . . . . . . 7 XENG3781 . . . . . . . . . . 7 XENG3791 . . . . . . . . . . 7 XENT1192 . . . . . . . . . . 7 ZA2BB2 . . . . . . . . . . . . 8 ZA2BB4 . . . . . . . . . . . . 8 ZA2BC44 . . . . . . . . . . . 8 ZA2BD2 . . . . . . . . . . . . 8 ZA2BD3 . . . . . . . . . . . . 8 ZA2BG4 . . . . . . . . . . . . 8 ZA2BG5 . . . . . . . . . . . . 8 ZA2BS14 . . . . . . . . . . . 8 ZA2BS44 . . . . . . . . . . . 8 ZA2BS54 . . . . . . . . . . . 8 ZA2BS74 . . . . . . . . . . . 8 ZA2BS834 . . . . . . . . . . 8 ZA2BS844 . . . . . . . . . . 8 ZA2BV03 . . . . . . . . . . . 8 ZA2BV033 . . . . . . . . . . 8 ZA2BV04 . . . . . . . . . . . 8 ZA2BV05 . . . . . . . . . . 8 ZA2BV053 . . . . . . . . . 8 ZA2BV06 . . . . . . . . . . 8 ZB2BE101 . . . . . . . . . 7 ZB2BE102 . . . . . . . . . 7 ZB2BV006 . . . . . . . . . 8 ZB2BV007 . . . . . . . . . 8 ZB2BY2002 . . . . . . . 10 ZB2BY2004 . . . . . . . 10 ZB2BY2101 . . . . . . . 10 ZB2BY23 . . . . . . . . . 10 ZB2BY2303 . . . . . . . 10 ZB2BY2304 . . . . . . . 10 ZB2BY2305 . . . . . . . 10 ZB2BY2306 . . . . . . . 10 ZB2BY2307 . . . . . . . 10 ZB2BY2308 . . . . . . . 10 ZB2BY2309 . . . . . . . 10 ZB2BY2310 . . . . . . . 10 ZB2BY2311 . . . . . . . 10 ZB2BY2312 . . . . . . . 10 ZB2BY2313 . . . . . . . 10 ZB2BY2314 . . . . . . . 10 ZB2BY2321 . . . . . . . 10 ZB2BY2323 . . . . . . . 10 ZB2BY2326 . . . . . . . 10 ZB2BY2327 . . . . . . . 10 ZB2BY2328 . . . . . . . 10 ZB2BY2330 . . . . . . . 10 ZB2BY2334 . . . . . . . 10 ZB2BY2335 . . . . . . . 10 ZB2BY2336 . . . . . . . . 10 ZB2BY2337 . . . . . . . . 10 ZB2BY2338 . . . . . . . . 10 ZB2BY2339 . . . . . . . . 10 ZB2BY2341 . . . . . . . . 10 ZB2BY2342 . . . . . . . . 10 ZB2BY2343 . . . . . . . . 10 ZB2BY2344 . . . . . . . . 10 ZB2BY2345 . . . . . . . . 10 ZB2BY2346 . . . . . . . . 10 ZB2BY2365 . . . . . . . . 10 ZB2BY2366 . . . . . . . . 10 ZB2BY2367 . . . . . . . . 10 ZB2BY2369 . . . . . . . . 10 ZB2BY2370 . . . . . . . . 10 ZB2BY2372 . . . . . . . . 10 ZB2BY2376 . . . . . . . . 10 ZB2BY2380 . . . . . . . . 10 ZB2BY2381 . . . . . . . . 10 ZB2BY2384 . . . . . . . . 10 ZB2BY2387 . . . . . . . . 10 ZB2BY2388 . . . . . . . . 10 ZB2BY2389 . . . . . . . . 10 ZB2BY2503 . . . . . . . . 10 ZB2BY4001 . . . . . . . . 10 ZB2BY4005 . . . . . . . . 10 ZB2BY4101 . . . . . . . . 10 ZB2SZ3 . . . . . . . . . . . . 8 19 (c) 2010 Schneider Electric All Rights Reserved 12/2010 Schneider Electric USA, Inc. 8001 Knightdale Blvd. Knightdale, NC 27545 USA 1-888-Square D 1-888-778-2733 www.schneider-electric.us Square D(R) and Schneider Electric(R) are trademarks or registered trademarks of Schneider Electric and/or its affiliates in the United States and/or other countries. Other marks used herein may be the property of their respective owners. 9001CT1001 (c) 2010 Schneider Electric All Rights Reserved 12/2010